  • RAID1: can't replace faulty spare (marked again as 'faulty spare' within seconds)

    - by user212475
    I got a problem that I cannot solve: Our fileserver runs XUbuntu and 3 RAID1s. One has a problem since monday: it consists of sdb and sdc. sdb was marked as faulty by mdadm for unknown reasons. I used --remove to remove it from the RAID and then to add it by --add. All was fine, re-syncing started but never got above 0% and after a few seconds, sdb was again marked as 'faulty spare' (and therefore the RAID degraded, but clean). So I saved the first 512 byte of the old sdb to a file, bought a new HDD of same size (4TB), shut down the computer and replaced sdb physically, switched the computer back on and wrote the 512 byte back to the new drive to have the same partition info as the old drive (both are the same type, from same company). But the new drive shows the same behaviour as the old: I can add, re-syncing starts and after a few seconds its marked as 'faulty spare'. Here exactly what i did: mdadm --remove /dev/md/1 /dev/sdb maadm --detail /dev/md/1 gives me: /dev/md/1: Version : 1.2 Creation Time : Sat Jun 8 22:32:05 2013 Raid Level : raid1 Array Size : 3906887360 (3725.90 GiB 4000.65 GB) Used Dev Size : 3906887360 (3725.90 GiB 4000.65 GB) Raid Devices : 2 Total Devices : 1 Persistence : Superblock is persistent Update Time : Thu Nov 7 06:56:13 2013 State : clean, degraded Active Devices : 1 Working Devices : 1 Failed Devices : 0 Spare Devices : 0 Name : File-Server:1 (local to host File-Server) UUID : 44ed561f:b733e946:e69820f4:aba9b223 Events : 2424 Number Major Minor RaidDevice State 0 0 0 0 removed 1 8 32 1 active sync /dev/sdc mdadm --add /dev/md/1 /dev/sdb mdadm --detail /dev/md/1 gives me: Version : 1.2 Creation Time : Sat Jun 8 22:32:05 2013 Raid Level : raid1 Array Size : 3906887360 (3725.90 GiB 4000.65 GB) Used Dev Size : 3906887360 (3725.90 GiB 4000.65 GB) Raid Devices : 2 Total Devices : 2 Persistence : Superblock is persistent Update Time : Thu Nov 7 06:57:49 2013 State : clean, degraded, recovering Active Devices : 1 Working Devices : 1 Failed Devices : 1 Spare Devices : 0 Rebuild Status : 0% complete Name : File-Server:1 (local to host File-Server) UUID : 44ed561f:b733e946:e69820f4:aba9b223 Events : 2431 Number Major Minor RaidDevice State 2 8 16 0 faulty spare rebuilding /dev/sdb 1 8 32 1 active sync /dev/sdc and after a few seconds: /dev/md/1: Version : 1.2 Creation Time : Sat Jun 8 22:32:05 2013 Raid Level : raid1 Array Size : 3906887360 (3725.90 GiB 4000.65 GB) Used Dev Size : 3906887360 (3725.90 GiB 4000.65 GB) Raid Devices : 2 Total Devices : 2 Persistence : Superblock is persistent Update Time : Thu Nov 7 06:57:50 2013 State : clean, degraded Active Devices : 1 Working Devices : 1 Failed Devices : 1 Spare Devices : 0 Name : File-Server:1 (local to host File-Server) UUID : 44ed561f:b733e946:e69820f4:aba9b223 Events : 2436 Number Major Minor RaidDevice State 0 0 0 0 removed 1 8 32 1 active sync /dev/sdc 2 8 16 - faulty spare /dev/sdb same behaviour if I zero the superblock (mdadm --zero-superblock /dev/sdb) before adding sdb. I do all commands as root and the system holds 3 more 4TB drives, ie the mainboard can handle them. The old harddrive was checked for errors using badblocks, but all is fine. Does anybody have any idea, what the problem is?

    Read the article

  • Ubuntu 10.04 & IBM DS3524 with FC multipath, inactive path is [failed][faulty] instead of [active][ghost]

    - by Graeme Donaldson
    OK, this is my setup: FC Switches IBM/Brocade, Switch1 and Switch2, independent fabrics. Server IBM x3650 M2, 2x QLogic QLE2460, 1 connected to each FC Switch. Storage IBM DS3524, 2x controllers with 4x FC ports each, but only 2x connected on each. +-----------------------------------------------------------------------+ | HBA1 Server HBA2 | +-----------------------------------------------------------------------+ | | | | | | +-----------------------------+ +------------------------------+ | Switch1 | | Switch2 | +-----------------------------+ +------------------------------+ | | | | | | | | | | | | | | | | | | | | +-----------------------------------+-----------------------------------+ | Contr A, port 3 | Contr A, port 4 | Contr B, port 3 | Contr B, port 4 | +-----------------------------------+-----------------------------------+ | Storage | +-----------------------------------------------------------------------+ My /etc/multipath.conf is from the IBM redbook for the DS3500, except I use a different setting for prio_callout, IBM uses /sbin/mpath_prio_tpc, but according to http://changelogs.ubuntu.com/changelogs/pool/main/m/multipath-tools/multipath-tools_0.4.8-7ubuntu2/changelog, this was renamed to /sbin/mpath_prio_rdac, which I'm using. devices { device { #ds3500 vendor "IBM" product "1746 FAStT" hardware_handler "1 rdac" path_checker rdac failback 0 path_grouping_policy multibus prio_callout "/sbin/mpath_prio_rdac /dev/%n" } } multipaths { multipath { wwid xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx alias array07 path_grouping_policy multibus path_checker readsector0 path_selector "round-robin 0" failback "5" rr_weight priorities no_path_retry "5" } } The output of multipath -ll with controller A as the preferred path: root@db06:~# multipath -ll sdg: checker msg is "directio checker reports path is down" sdh: checker msg is "directio checker reports path is down" array07 (xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx) dm-2 IBM ,1746 FASt [size=4.9T][features=1 queue_if_no_path][hwhandler=0] \_ round-robin 0 [prio=2][active] \_ 5:0:1:0 sdd 8:48 [active][ready] \_ 5:0:2:0 sde 8:64 [active][ready] \_ 6:0:1:0 sdg 8:96 [failed][faulty] \_ 6:0:2:0 sdh 8:112 [failed][faulty] If I change the preferred path using IBM DS Storage Manager to Controller B, the output swaps accordingly: root@db06:~# multipath -ll sdd: checker msg is "directio checker reports path is down" sde: checker msg is "directio checker reports path is down" array07 (xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx) dm-2 IBM ,1746 FASt [size=4.9T][features=1 queue_if_no_path][hwhandler=0] \_ round-robin 0 [prio=2][active] \_ 5:0:1:0 sdd 8:48 [failed][faulty] \_ 5:0:2:0 sde 8:64 [failed][faulty] \_ 6:0:1:0 sdg 8:96 [active][ready] \_ 6:0:2:0 sdh 8:112 [active][ready] According to IBM, the inactive path should be "[active][ghost]", not "[failed][faulty]". Despite this, I don't seem to have any I/O issues, but my syslog is being spammed with this every 5 seconds: Jun 1 15:30:09 db06 multipathd: sdg: directio checker reports path is down Jun 1 15:30:09 db06 kernel: [ 2350.282065] sd 6:0:2:0: [sdh] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jun 1 15:30:09 db06 kernel: [ 2350.282071] sd 6:0:2:0: [sdh] Sense Key : Illegal Request [current] Jun 1 15:30:09 db06 kernel: [ 2350.282076] sd 6:0:2:0: [sdh] <<vendor>> ASC=0x94 ASCQ=0x1ASC=0x94 ASCQ=0x1 Jun 1 15:30:09 db06 kernel: [ 2350.282083] sd 6:0:2:0: [sdh] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 Jun 1 15:30:09 db06 kernel: [ 2350.282092] end_request: I/O error, dev sdh, sector 0 Jun 1 15:30:10 db06 multipathd: sdh: directio checker reports path is down Jun 1 15:30:14 db06 kernel: [ 2355.312270] sd 6:0:1:0: [sdg] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jun 1 15:30:14 db06 kernel: [ 2355.312277] sd 6:0:1:0: [sdg] Sense Key : Illegal Request [current] Jun 1 15:30:14 db06 kernel: [ 2355.312282] sd 6:0:1:0: [sdg] <<vendor>> ASC=0x94 ASCQ=0x1ASC=0x94 ASCQ=0x1 Jun 1 15:30:14 db06 kernel: [ 2355.312290] sd 6:0:1:0: [sdg] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 Jun 1 15:30:14 db06 kernel: [ 2355.312299] end_request: I/O error, dev sdg, sector 0 Does anyone know how I can get the inactive path to show "[active][ghost]" instead of "[failed][faulty]"? I assume that once I can get that right then the spam in my syslog will end as well. One final thing worth mentioning is that the IBM redbook doc targets SLES 11 so I'm assuming there's something a little different under Ubuntu that I just haven't figured out yet. Update: As suggested by Mitch, I've tried removing /etc/multipath.conf, and now the output of multipath -ll looks like this: root@db06:~# multipath -ll sdg: checker msg is "directio checker reports path is down" sdh: checker msg is "directio checker reports path is down" xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxdm-1 IBM ,1746 FASt [size=4.9T][features=0][hwhandler=0] \_ round-robin 0 [prio=1][active] \_ 5:0:2:0 sde 8:64 [active][ready] \_ round-robin 0 [prio=1][enabled] \_ 5:0:1:0 sdd 8:48 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 6:0:1:0 sdg 8:96 [failed][faulty] \_ round-robin 0 [prio=0][enabled] \_ 6:0:2:0 sdh 8:112 [failed][faulty] So its more or less the same, with the same message in the syslog every 5 minutes as before, but the grouping has changed.

    Read the article

  • Faulty memtest result

    - by dhojgaard
    I've been a bit suspicious about my RAM lately. They seem not work like i expect them to. For instance i run a lot of Virtual Test Environments in VMware Workstation and lately Ubuntu starts to lag just running 4 virtual machines each dedicated 512 MB. BTW im having 6GB memory on my laptop. This did not use to be a problem for me on my last laptop that even had a lot lower CPU resources. So i was led to try a memtest after reading some websites about RAM testing. So i did a memtest overnight but when i woke up this morning i was just looping and i could not Exit or do anything. It was just looping the number of errors besides test 7 which you can see in the lower right part of the screenshot. Can anyone interpret this screenshot for me? Do i have a faulty set of RAMs?

    Read the article

  • Using a parser to locate faulty code

    - by ryan.riverside
    Lately I've been working a lot in PHP and have run into an abnormally large number of parsing errors. I realize these are my own fault and a result of sloppy initial coding on my part, but it's getting to the point that I'm spending more time resolving tags than developing. In the interest of not slamming my productivity, are there any tricks to locating the problem in the code? What I'd really be looking for would be a line to put in the code which would output the entire faulty tag in the parsing error, or something similar. Purely for reference sake, my current error is Parse error: syntax error, unexpected '}' in /home/content/80/9480880/html/cache/tpl_prosilver_viewtopic_body.html.php on line 50 (which refers to this): </dd><dd><?php if ($_poll_option_val['POLL_OPTION_RESULT'] == 0) { echo ((isset($this->_rootref['L_NO_VOTES'])) ? $this->_rootref['L_NO_VOTES'] : ((isset($user->lang['NO_VOTES'])) ? $user->lang['NO_VOTES'] : '{ NO_VOTES }')); } else { echo $_poll_option_val['POLL_OPTION_PERCENT']; } ?></dd> </dl> <?php }} if ($this->_rootref['S_DISPLAY_RESULTS']) { ?> <dl> <dt>&nbsp;</dt> <dd class="resultbar"><?php echo ((isset($this->_rootref['L_TOTAL_VOTES'])) ? $this->_rootref['L_TOTAL_VOTES'] : ((isset($user->lang['TOTAL_VOTES'])) ? $user->lang['TOTAL_VOTES'] : '{ TOTAL_VOTES }')); ?> : <?php echo (isset($this->_rootref['TOTAL_VOTES'])) ? $this->_rootref['TOTAL_VOTES'] : ''; ?></dd> </dl> <?php } if ($this->_rootref['S_CAN_VOTE']) { ?> <dl style="border-top: none;"> <dt>&nbsp;</dt> <dd class="resultbar"><input type="submit" name="update" value="<?php echo ((isset($this->_rootref['L_SUBMIT_VOTE'])) ? $this->_rootref['L_SUBMIT_VOTE'] : ((isset($user->lang['SUBMIT_VOTE'])) ? $user->lang['SUBMIT_VOTE'] : '{ SUBMIT_VOTE }')); ?>" class="button1" /></dd> </dl> <?php } if (! $this->_rootref['S_DISPLAY_RESULTS']) { ?> <dl style="border-top: none;"> <dt>&nbsp;</dt> <dd class="resultbar"><a href="<?php echo (isset($this->_rootref['U_VIEW_RESULTS'])) ? $this->_rootref['U_VIEW_RESULTS'] : ''; ?>"><?php echo ((isset($this->_rootref['L_VIEW_RESULTS'])) ? $this->_rootref['L_VIEW_RESULTS'] : ((isset($user->lang['VIEW_RESULTS'])) ? $user->lang['VIEW_RESULTS'] : '{ VIEW_RESULTS }')); ?></a></dd> </dl> <?php } ?> </fieldset></div>

    Read the article

  • Does this mean the router is faulty?

    - by Ashfame
    I have a router to which I have my desktop (running Ubuntu) connected via LAN & I use it on my phone via wifi. Sometimes it happen that the LAN one will stop working for no reason but the wifi will work fine. And it will resolve away by itself. Since last night, the router was restarting again & again on its own, so I lodged a complaint about it and they said the router is faulty and will be replaced, but I know they don't know anything about how things work & is just going to shoot an arrow in the dark. These restarts has happened for the first time, LAN-wifi issue described earlier is a common one (but not frequent one). So is the router faulty or there is some issue from my ISP side which will continue to persist even after they change the router? My very best guess is that they will replace it with an older refurbished router which will tend to give me more troubles in the coming time, so its better if I change it only its faulty (this is a new one - 6months old, I am its first hand user). I am happy to provide any details.

    Read the article

  • Figuring out which PC part is faulty

    - by Davy8
    I have an odd scenario and I'm having trouble figuring out which is the faulty component. First of all, the video doesn't work, monitor says it's not getting a signal. Monitor's not faulty (works on other computer) so the first suspect was video card. However 2 things make me think it's not the video card. (Don't have another machine with PCIe around to test definitively) First, the GPU fan is spinning so it's getting power. Second, tried putting in an older PCI video card that is known to be working (pulled out of another working machine) and there's still no video. Normally if it's not the video card I'd suspect the motherboard, but everything's getting power on the mobo, so I'm not sure. The case apparently doesn't have system speakers, so can't hear any of the diagnostic beeps either. Also not sure whether a faulty CPU would cause no image at all either. The parts are brand new so something's going to get RMA'd but I'm not sure which component is to blame in this case. (Only slightly related, but I also accidentally put too much thermal paste on the CPU. The fan/heatsink instructions said to put the whole tube which seemed like a lot compared to previous experience, and as I started squeezing I knew it was definitely too much and stopped at about 1/3 but against my better judgement I didn't wipe any off. I'm not sure whether that would cause problems other than not cooling as effectively as it should)

    Read the article

  • MDADM RAID5 array showing as CLEAN FAULTY

    - by Dean Reilly
    A drive dropped out of my raid 5 array yesterday. It looks like the reason was due to a bad controller so I switched it out and attempted to re-add the drive but mdadm claimed it couldn't do it. So I zerod the superblock and just added the drive normally and left it to resync. When I came to check on the array this morning I was unable to mount it at all and it's now showing as CLEAN FAULTY with two drives missing. The two missing drives are listed as spare and faulty spare. Is there anything I can do in this situation or is the array gone?

    Read the article

  • How to accelerate and notice failure of potentially faulty disks

    - by rainier
    Hey, I got a bunch of 'used' servers, whose disks should have been checked, but they have been shipped around the county in crate which can't help. I just had one disk go bad (despite being mirrored, currently trying to get more details). The server was fine for about a week before everything ground to a halt this afternoon. Is there any way 'accelerate' the failure of faulty disks, with the goal of bringing the disk to failure before we launch production services? Would doing lots of I/O with 'dd' or 'iozone' be a good way to test these potentially faulty disks? Any other tests/tools that would help recognized failures before they happen?

    Read the article

  • Can a faulty DNS record prevent networking?

    - by Bob
    My server's network interfaces are not available anymore since yesterday evening. I didn't change anything, but I added a new DNS-record shortly before. Unfortunately, the web interface I used to add this DNS record escaped some characters, so I've got a faulty DNS record: example.com 86400 IN TXT "\"v=spf1 mx a -all\"" However, this is the only unusual thing I could notice about this. Is it possible that the \-characters in my DNS record are confusing for some routers? Or could it be the system itself which is confused by this (it's a Debian Lenny system). Unfortunately, I can't quick-test it because of the long TTL of the record.

    Read the article

  • Ubuntu 10.04 preseed unattended install results in faulty partition table

    - by joschi
    I'm currently trying to set up an unattended installation of Ubuntu 10.04 (Lucid Lynx) through preseeding. But whenever I try to create a custom partition scheme, the Debian installer (which Ubuntu is using) produces a faulty partition table. I've taken the partition scheme described in the example preseed file: d-i partman-auto/expert_recipe string \ boot-root :: \ 40 50 100 ext3 \ $primary{ } $bootable{ } \ method{ format } format{ } \ use_filesystem{ } filesystem{ ext3 } \ mountpoint{ /boot } \ . \ 500 10000 1000000000 ext3 \ method{ format } format{ } \ use_filesystem{ } filesystem{ ext3 } \ mountpoint{ / } \ . \ 64 512 300% linux-swap \ method{ swap } format{ } \ . Unfortunately it also produces an incorrect partition table on the disk. The installation process itself is working and the installed system eventually boots and is working, as far as I can tell. But fdisk and cfdisk are still complaining: # fdisk -l /dev/sda Disk /dev/sda: 17.2 GB, 17179869184 bytes 255 heads, 63 sectors/track, 2088 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000a1cdd Device Boot Start End Blocks Id System /dev/sda1 * 1 5 37888 83 Linux Partition 1 does not end on cylinder boundary. /dev/sda2 5 2089 16736257 5 Extended /dev/sda5 5 2013 16121856 83 Linux /dev/sda6 2013 2089 613376 82 Linux swap / Solaris cfdisk even refuses to start at all: # cfdisk /dev/sda FATAL ERROR: Bad primary partition 1: Partition ends in the final partial cylinder parted on the other hand does not complain about the cylinder boundary of /dev/sda1: # parted /dev/sda p Model: VMware Virtual disk (scsi) Disk /dev/sda: 17.2GB Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 1049kB 39.8MB 38.8MB primary ext4 boot 2 40.9MB 17.2GB 17.1GB extended 5 40.9MB 16.5GB 16.5GB logical ext4 6 16.6GB 17.2GB 628MB logical linux-swap(v1) Since the installed system is working, it shouldn't be a big problem but I'm afraid that this will mean trouble in the future.

    Read the article

  • Disabling Laptop (PB TJ-75) faulty card reader Linux

    - by Gab
    My problem comes from that my laptop [PB TJ-75] has a faulty Alcor card reader. It’s 100% sure, the device is dead and unusable whatever the OS is. It cannot be disabled in BIOS [latest: Vendor: Phoenix Technologies LTD Version: V1.26 Release Date: 05/04/2010]. If I could take it apart from the main board easily, and if with that, the system would never look again for it, I’ll be very happy! Is it possible, has anyone ever tried this? Or maybe, replacing the BIOS with a more open one, which let you disable the card reader. Does this exists? Here's what I've tried to disable it so far. In Win7, I choose ‘disable’ in device manager and that’s ok. If not, the device keeps on appearing and disappearing and lot of resources are used. In Lubuntu 13.04, I got extra boot time, with the msg:'sdb, assuming drive cache, etc.’ I tried other distros (isos booted by grub). I can boot Puppy, Gparted, and Redobackup apparently without any problem. I cannot boot Debian, live or install + tried Crunchbang and Tails. I got a loop :’usb device, scsi n+1 blabla‘. I tried "nousb", no result, I have blacklisted EHCI, no result, then usb_storage module, better boot time in Lubuntu, with just the message "...data transfer failed", better shutdown time too. But, no way to use usb storage medias. In Debian, it ends with BusyBox prompt. Is it possible to just disable that Alcor card reader? Does it have a specific module? Is there a special kernel boot option that I missed? Does it have something to do with kernel recompiling, and if yes, how to do with isos? Programming a driver which says everything is ok (out of my comprehension for the moment)? Disabling device by vendor id? What is the best way?

    Read the article

  • A faulty Caviar Blue hard drive?

    - by Glister
    We have a small "homemade" server running fully updated Debian Wheezy (amd64). One hard drive installed: WDC WD6400AAKS. The motherboard is ASUS M4N68T V2. The usual load: CPU: an average of 20% Each week about 50GB of additional space is occupied. About 47GB of uploaded files and 3GB of MySQL data. I'm afraid that the hard drive may be about to fail. I saw Pre-fail on few places when I ran: root@SERVER:/tmp# smartctl -a /dev/sda smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-4-amd64] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: Western Digital Caviar Blue Serial ATA Device Model: WDC WD6400AAKS-XXXXXXX Serial Number: WD-XXXXXXXXXXXXXXXXXXX LU WWN Device Id: 5 0014ee XXXXXXXXXXXXX Firmware Version: 01.03B01 User Capacity: 640,135,028,736 bytes [640 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Mon Oct 28 18:55:27 2013 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x85) Offline data collection activity was aborted by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 247) Self-test routine in progress... 70% of test remaining. Total time to complete Offline data collection: (11580) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 136) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0027 157 146 021 Pre-fail Always - 5108 4 Start_Stop_Count 0x0032 098 098 000 Old_age Always - 2968 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 200 200 051 Old_age Always - 0 9 Power_On_Hours 0x0032 079 079 000 Old_age Always - 15445 10 Spin_Retry_Count 0x0032 100 100 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 100 051 Old_age Always - 0 12 Power_Cycle_Count 0x0032 098 098 000 Old_age Always - 2950 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 426 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 2968 194 Temperature_Celsius 0x0022 111 095 000 Old_age Always - 36 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 160 000 Old_age Always - 21716 200 Multi_Zone_Error_Rate 0x0008 200 200 051 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 15444 - Error SMART Read Selective Self-Test Log failed: scsi error aborted command Smartctl: SMART Selective Self Test Log Read Failed root@SERVER:/tmp# In one tutorial I read that the pre-fail is a an indication of coming failure, in another tutorial I read that it is not true. Can you guys help me decode the output of smartctl? It would be also nice to share suggestions what should I do if I want to ensure data integrity (about 50GB of new data each week, up to 2TB for the whole period I'm interested in). Maybe I will go with 2x2TB Caviar Black in RAID4?

    Read the article

  • Power scheme faulty [closed]

    - by user40287
    Hi, I use a laptop. When I take the power cable out to run on batteries, the screen darkens, as it is no longer so bright, to save on battery power. When I put the power cable back in, the screen brightens back to it's original brightness. However, I have since replaced the power cable, and the screen remains darkened. How do I regain the original brightness? Thanks, Steve

    Read the article

  • Power scheme faulty

    - by user40287
    Hi, I use a laptop. When I take the power cable out to run on batteries, the screen darkens, as it is no longer so bright, to save on battery power. When I put the power cable back in, the screen brightens back to it's original brightness. However, I have since replaced the power cable, and the screen remains darkened. How do I regain the original brightness? Thanks, Steve

    Read the article

  • iPhone contact list emptied due to faulty sync?

    - by i-g
    When I'm in an area with unreliable AT&T cell data reception (e.g. all of Manhattan during the day), my contact list sometimes disappears, and does not reappear for an extended period of time, sometimes hours. Does anyone know why this would happen? Would using manual-only sync remedy this? If I'm using manual sync by turning push sync off, how do I trigger a manual sync?

    Read the article

  • Laptop not charging when connected to mains outlet

    - by Josh
    I've had this laptop for a few weeks now, it's a Sony Vaio. I went to charge it a few days ago and plugged in the power cable, but it's not charging. The battery icon in the Windows taskbar to the bottom right says it's plugged in and charging, but the charge level never goes above 2%. I have checked and I don't have a hcarging switch on the laptop anywhere, so it should be charging. If I unplug the cable, the laptop runs out of power within 30 seconds or so, further fueling my thought that it's a faulty battery. Anyone have any bright ideas? If this doesn't get fixed I'll just ring up Sony and get them to send me a replacement battery or something. Thanks.

    Read the article

  • Java Web Service - Faulty Services - ClassNotFound Exception

    - by Epitaph
    My Project has 2 java files (A.java and B.java in same package). A.java uses methods in B.java. And, an external jar has been added in the project build path. In order to create a web service (bottom up) from the class, I created a new Dynamic Web Project in Eclipse with axis2 as the runtime platform, and imported A.java and B.java source files. Next, since all my methods that need to be exposed are contained in A.java, I right click on it and created web service using the standard settings. When I deploy the web service on my apache, I get "Fault Service" and a few ClassNotFound Exceptions for some of the classes in my external jar file (I have already imported it as an external jar). Does the external jar needs to be imported in another way?

    Read the article

  • JTextPane insert component, faulty vertical alignment

    - by John O
    I have a JTextPane, into which I need to insert a JComponent. I'm using JTextPane.insertComponent(Component). The item is indeed inserted, but the vertical positioning is too high. Instead of having the bottom of the component aligned with the baseline of the current line of text, the component is way above that position, blocking out/over-painting lines of text appearing above. I have tried calling setAlignmentY(float) with various values, on both the inserted component and the JTextPane, but it doesn't affect the behavior at all. My guess: there seems to be some state inside my JTextPane or its Document that I need to be changing. But I don't know what it is. John

    Read the article

  • jquery image slide procedure faulty in IE

    - by sahulik
    Where did I go wrong? IE reports a problem while everything else seems to be just fine. $(document).ready(function(){ menu = $('#menu > ul > li'); image = $('#image > ul > li > div'); menu.each(function(idx) { this.slide = image[idx]; }).hover( function() { menu.removeClass('active'); image.removeClass('active'); $(this).addClass('active'); $(this.slide).addClass('active'); }); });

    Read the article

  • How do I stop sound coming from my speakers with a faulty headphone socket?

    - by Andy
    On my laptop, I have a faulty headphone socket, so when I insert headphones into it, the speakers do not mute. I can confirm that this problem is caused by faulty hardware and not software as when I twist the headphone jack, the speakers come on and off according to the movements. On previous versions of Ubuntu, I worked around this problem by going into alsamixer and disabling "Auto-Mute Mode", and then going into the sound settings and choosing "Analog Headphones". However, on 12.04, no such option exists, rendering my headphones unusable with no way to work around the problem. I momentarily thought I had this problem fixed when I installed PulseAudio Volume Control from the Software Centre. I selected the Output Devices tab, and under "Built-in Audio Analogue Stereo" I selected "Headphones" for the port. However, this almost randomly seems to change back to "Speakers", despite me setting "Auto-Mute Mode" as disabled. Basically, I would like a way to permanently mute the speakers so only the headphones will play sound, without it losing my settings. It is ridiculous that such a simple setting has been taken away to "simplify" the user interface.

    Read the article

  • Should my program "be lenient" in what it accepts and "discard faulty input silently"?

    - by romkyns
    I was under the impression that by now everyone agrees this maxim was a mistake. But I recently saw this answer which has a "be lenient" comment upvoted 137 times (as of today). In my opinion, the leniency in what browsers accept was the direct cause of the utter mess that HTML and some other web standards were a few years ago, and have only recently begun to properly crystallize out of that mess. The way I see it, being lenient in what you accept will lead to this. The second part of the maxim is "discard faulty input silently, without returning an error message unless this is required by the specification", and this feels borderline offensive. Any programmer who has banged their head on the wall when something fails silently will know what I mean. So, am I completely wrong about this? Should my program be lenient in what it accepts and swallow errors silently? Or am I mis-interpreting what this is supposed to mean? Taken to the extreme, if Excel followed this maxim and I gave it an exe file to open, it would just show a blank spreadsheet without even mentioning that anything went wrong. Is this really a good principle to follow?

    Read the article

  • How do I make the PolicyKit authentication agent window not dissapear when I enter faulty password in Ubuntu 12.04?

    - by Petar
    As far as I remember in previous versions of Ubuntu, whenever authentication was required and when the PolicyKit authentication agent window was presented, it stayed there even after I would enter a faulty password. But now, whenever I make a mistake, the window is closed immediately. I find this behaviour irritating. For instance I use Synaptic rather frequently, and I prefer to start it using Synapse. I press Ctrl+Space to invoke Synapse, then I enter "syn" (s-shows SMplayer, sy- shows System Monitor) and than I press Enter so that Synaptic is invoked. Then I'm presented with the PolicyKit authentication agent window. As my password is rather complicated - using special characters and big letters, it's easy to make a mistake. If I do make a mistake while typing my password, I'm forced to redo all the previous steps. It's annoying as hell, knowing that this is not the way the PolicyKit authentication agent window behaved before. It used to warn me that the password was not correct and than wait for the correct input. I'm not sure if it allowed trying for the correct password indefinitely, or it was limited to 3 retries which is a much saner behaviour than the current one. I'm using Gnome 3, but the same thing happens in Unity too, although the window looks different.

    Read the article

  • Should a server "be lenient" in what it accepts and "discard faulty input silently"?

    - by romkyns
    I was under the impression that by now everyone agrees this maxim was a mistake. But I recently saw this answer which has a "be lenient" comment upvoted 137 times (as of today). In my opinion, the leniency in what browsers accept was the direct cause of the utter mess that HTML and some other web standards were a few years ago, and have only recently begun to properly crystallize out of that mess. The way I see it, being lenient in what you accept will lead to this. The second part of the maxim is "discard faulty input silently, without returning an error message unless this is required by the specification", and this feels borderline offensive. Any programmer who has banged their head on the wall when something fails silently will know what I mean. So, am I completely wrong about this? Should my program be lenient in what it accepts and swallow errors silently? Or am I mis-interpreting what this is supposed to mean? The original question said "program", and I take everyone's point about that. It can make sense for programs to be lenient. What I really meant, however, is APIs: interfaces exposed to other programs, rather than people. HTTP is an example. The protocol is an interface that only other programs use. People never directly provide the dates that go into headers like "If-Modified-Since". So, the question is: should the server implementing a standard be lenient and allow dates in several other formats, in addition to the one that's actually required by the standard? I believe the "be lenient" is supposed to apply to this situation, rather than human interfaces. If the server is lenient, it might seem like an overall improvement, but I think in practice it only leads to client implementations that end up relying on the leniency and thus failing to work with another server that's lenient in slightly different ways. So, should a server exposing some API be lenient or is that a very bad idea? Now onto lenient handling of user input. Consider YouTrack (a bug tracking software). It uses a language for text entry that is reminiscent of Markdown. Except that it's "lenient". For example, writing - foo - bar - baz is not a documented way of creating a bulleted list, and yet it worked. Consequently, it ended up being used a lot throughout our internal bugtracker. Next version comes out, and this lenient feature starts working slightly differently, breaking a bunch of lists that (mis)used this (non)feature. The documented way to create bulleted lists still works, of course. So, should my software be lenient in what user inputs it accepts?

    Read the article

  • Is it possible for a faulty processor to cause audio static/noise?

    - by Tom
    I have a Core 2 Extreme processor I received from a friend and have set up an XBMC box using it. However, I constantly get audio static whenever playing any music or videos. Here is a video of the sound: http://www.youtube.com/watch?v=SqKQkxYRVA4 I have tried replacing everything short of the case and the processor, including cables, audio interfaces, operating systems, ram, etc, leading me to think it might be either the case shorting out the motherboards I have tried or a faulty processor. Is it possible for a faulty processor to cause audio static/noise? Any feedback would be appreciated. Edit - Here's a list of things I have tried: Reinstalling OS Installing/upgrading/repairing PulseAudio/Alsa Installing alternate OSes, straight Ubuntu, Lubuntu, Xubuntu, Arch, Mint, Windows 7 Switching audio from the external card to internal Optical, audio out through HDMI, audio out through headphones Different ports on receiver (my main desktop sounds fine on the same sound system) Different optical cables Unplugging everything unnecessary from the motherboard (1 HD, 1 Stick of Ram, 1 Keyboard) Swapping out ram Swapping out the motherboard Replacing the Graphics Card (was replaced due to fan being noisy, not specifically for this problem) Different harddrives Swapping power supply Disabling onboard audio Switching Power Cable Plugging in through surge protector Plugging into different outlet on separate circuit

    Read the article