Search Results

Search found 60691 results on 2428 pages for 'super button'.

Page 102/2428 | < Previous Page | 98 99 100 101 102 103 104 105 106 107 108 109  | Next Page >

  • How to skip interstitial in a django view if a user hits the back button?

    - by Jose Boveda
    I have an application with an interstitial page to hold the user while an intensive operation runs in the background (takes anywhere from 30 secs to 1 minute). Once the operation is done, the user is redirected to the results page. Once on the result page, typical user behavior is to hit the 'back' button to perform the operation on a different input set. However, the back button takes them to the interstitial, not the original form. The desired behavior is to go back to the original form, skipping the interstitial entirely. I'd like this to be default behavior if the user goes to the interstitial page from anywhere but the original form. I thought I could create this by using the @never_cache function decorator in my view for the interstitial, and logic based on request.META['HTTP_REFERER'], however the page doesn't respect these. The browser's back button still trumps this behavior. Any ideas on how to solve this issue?

    Read the article

  • iPhone: How do I override the back button in a Navigation Controller?

    - by Angelo Stracquatanio
    Hello, In my app I have a basic Navigation Controller. For all of my views, except one, the controller works as it should. However, for one view in particular, I would like the 'back' button to not go back to the previous view, but to go to one I set. In particular it is going to go back 2 views and skip over one. After doing some research I found that I can intercept the view when it disappears, so I tried to put in code to have it navigate to the page I would like: - (void)viewWillDisappear:(BOOL)animated { [super viewWillDisappear:animated]; //i set a flag to know that the back button was pressed if (viewPushed) { viewPushed = NO; } else { // Here, you know that back button was pressed mainMenu *mainViewController = [[mainMenu alloc] initWithNibName:@"mainMenu" bundle:nil]; [self.navigationController pushViewController:mainViewController animated:YES]; [mainViewController release]; } } That didn't work, so does anyone have any ideas? Thanks!!

    Read the article

  • Button to add value to array and then compare result with another array on IPhone.

    - by slickplaid
    I have ten buttons that each correspond to a different number. I'm looking to record the order that these buttons are pressed and enter them into an array and then compare it to another array that is static in the app. The check should be done on the Nth button press, where N equals the number of items in the other, static array. How do I A) have a button press add a value to an array B) stop after Nth button press equal to amount of numbers in the array I'm checking against and C) compare this array to the other array?

    Read the article

  • EditText and Button on the same line with Textiew underneath?

    - by Kevin
    Hi, I am trying to have an EditText widget next to a button with a text view underneath. The EditText should resize and fill the screen accordingly, while the button's width is always only what it needs to be by setting the width to wrap_content. The layout should not be relative. Below is the code I have so far some of which was found here on StackOverflow. Removing the text view gives the desired appearance for the EditText and button, but when the TextView is added the view goes to ... well. Not sure why the code is not showing? I put it into a < code< pre block without success. http://pastebin.com/WgH6qrTm

    Read the article

  • how to set layout_weight programmatically for alert dialog button?

    - by Are
    Hi, Iam planing to give create 3 buttons with layout_weight=1, not interested in custom dialog.So I have written below code.It is not working.Always yes button gives me null. Whats wrong in this code? AlertDialog dialog= new AlertDialog.Builder(this).create(); dialog.setIcon(R.drawable.alert_icon); dialog.setTitle("title"); dialog.setMessage("Message"); dialog.setButton(AlertDialog.BUTTON_POSITIVE,"Yes", new DialogInterface.OnClickListener() { @Override public void onClick(DialogInterface arg0, int arg1) { } }); Button yesButton = dialog.getButton(AlertDialog.BUTTON_POSITIVE); Log.w("Button",""+yesButton);//here getting null LinearLayout.LayoutParams layoutParams = new LinearLayout.LayoutParams(LayoutParams.FILL_PARENT, LayoutParams.WRAP_CONTENT, 1f); yesButton.setLayoutParams(layoutParams); dialog.show(); Regards, Android developer.

    Read the article

  • How do I find the previous/default value of a radio button in JS?

    - by royrules22
    I'm not sure if this is even possible, but I figured I'd ask before clubbing togehter an ugly solution. What I have is a group of radio buttons and I want to trigger a function if the radio button value is changed. For example say there are three buttons X Y and Z with Y default selected. If a user clicks on an unselected button (i.e. X or Z) then the function gets triggered but if he/she clicks on Y (which is already selected) nothing happens. Naturally the best solution would be to fire the function on an onchange event but IE6 doesn't fire onchange until the focus is no longer on the element which is not satisfactory. So is there a way to know what the previous value of the radio button was or at least what its default value is? I could easily create an array of default values and check against that but I'm trying to reduce the overhead. Please no jQuery suggestions ;)

    Read the article

  • How can we know which cell is touched in tablView when a custom button in the cell is touched ?

    - by srikanth rongali
    I need to know which cell is touched when any button inside the cell is touched. I have custom UIButton *button1 in the cell and UIButton *button2 on the cell.imageView.image of the cell. I wrote selectors for both buttons.; But, I could not differentiate the buttons for each cell. How do I know which cell button was touched. What to do, to know that a particular cell's button was touched ? Thank you.

    Read the article

  • WPF: In Expression Blend, how to change Foreground of a custom button with a Border on different states?

    - by SubmarineX
    In Expression Blend 4, I want to change the Foreground of a custom button on different states. I'm just able to change the Background and BorderBrush. Just like this: If the state is "Normal", the color of text "Button" is Black, while the state is "Pressed", the color of text "Button" is White. On Brushes Panel under Properties Panel, there're 3 properties but no Foreground property: Who can help me? I'm so perplexed. Edit I find ContentControl have a Foreground property, but ContentPresenter haven't. Wether I should use ContentControl instead of ContentPresenter?

    Read the article

  • how to databind a datalist's page index to a button's commandname?

    - by korben
    i got this inside a button inside a datalist CommandName="<%# Container.ItemIndex %>" when i click the button, i'm expecting commandname to = 0, then 1, then 2, etc, as the datalist progresses, and i'm using that value in the button click's c# but i'm getting this error, i'm pretty sure i'm using this exact setup on another page and i have no problems, any idea what's going on? Server Error in '/' Application. Compilation Error Description: An error occurred during the compilation of a resource required to service this request. Please review the following specific error details and modify your source code appropriately. Compiler Error Message: CS0117: 'System.Web.UI.Control' does not contain a definition for 'ItemIndex'

    Read the article

  • How to retrieve ID of button clicked within usercontrol on Asp.net page?

    - by Shawn Gilligan
    I have a page that I am working on that I'm linking multiple user controls to. The user control contains 3 buttons, an attach, clear and view button. When a user clicks on any control on the page, the resulting information is "dumped" into the last visible control on the page. <%@ Page Language="C#" AutoEventWireup="true" CodeFile="Default.aspx.cs" Inherits="Default" MasterPageFile="DefaultPage.master" %> <%@ Register Assembly="AjaxControlToolkit" Namespace="AjaxControlToolkit" TagPrefix="ajaxToolkit" %> <%@ Register tagName="FileHandler" src="FileHandling.ascx" tagPrefix="ucFile" %> <asp:Content ID="Content1" ContentPlaceHolderID="Main" Runat="Server"> <asp:UpdatePanel ID="upPanel" UpdateMode="Conditional" runat="server"> <ContentTemplate> <table> <tr> <td> <ucFile:FileHandler ID="fFile1" runat="server" /> </td> <td> <ucFile:FileHandler ID="fFile2" runat="server" /> </td> </tr> </table> </ContentTemplate> </asp:UpdatePanel> </asp:Content> All file handling and processing is handled within the control, with an event when the upload to the file server is complete via a file name that was generated. When either button is clicked, the file name is always stored internal to the control in the last control's text box. Control code: <table style="width: 50%;"> <tr style="white-space: nowrap;"> <td style="width: 1%;"> <asp:Label runat="server" ID="lblFile" /> </td> <td style="width: 20%;"> <asp:TextBox ID="txtFile" CssClass="backColor" runat="server" OnTextChanged="FileInformationChanged" /> </td> <td style="width: 1%"> <%--<asp:Button runat="server" ID="btnUpload" CssClass="btn" Text="Attach" OnClick="UploadFile"/>--%> <input type="button" id="btnUpload" class="btn" tabindex="30" value="Attach" onclick="SetupUpload();" /> </td> <td style="width: 1%"> <%--<asp:Button runat="server" ID="btnClear" Text="Clear" CssClass="btn" OnClick="ClearTextValue"/>--%> <input type="button" id="btnClearFile" class="btn" value="Clear" onclick="document.getElementById('<%=txtFile.ClientID%>').value = '';document.getElementById('<%=hfFile.ClientID%>').value = '';" /> </td> <td style="width: 1%"> <a href="#here" onclick="ViewLink(document.getElementById('<%=hfFile.ClientID%>').value, '')">View</a> </td> <td style="width: 1%"> <asp:HiddenField ID="hfFile" runat="server" /> </td> </tr> </table> <script type="text/javascript"> var ItemPath = ""; function SetupUpload(File) { ItemPath = File; VersionAttach('<%=UploadPath%>', 'true'); } function UploadComplete(File) { document.getElementById('<%=txtFile.ClientID%>').value = File.substring(File.lastIndexOf("/") + 1); document.getElementById('<%=hfFile.ClientID%>').value = File; alert('<%=txtFile.Text %>'); alert('<%=ClientID %>') } function ViewLink(File, Alert) { if (File != "") { if (File.indexOf("../data/") != -1) { window.open(File, '_blank'); } else { window.open('../data/<%=UploadPath%>/' + File, '_blank'); } } else if (Alert == "") { alert('No file has been uploaded for this field.'); } } </script>

    Read the article

  • Issue with Multiple ModalPopups, ValidationSummary and UpdatePanels

    - by Aaron Hoffman
    I am having an issue when a page contains multiple ModalPopups each containing a ValidationSummary Control. Here is the functionality I need: A user clicks a button and a Modal Popup appears with dynamic content based on the button that was clicked. (This functionality is working. Buttons are wrapped in UpdatePanels and the partial page postback calls .Show() on the ModalPopup) "Save" button in ModalPopup causes client side validation, then causes a full page postback so the entire ModalPopup disappears. (ModalPopup could disappear another way - the ModalPopup just needs to disappear after a successful save operation) If errors occur in the codebehind during Save operation, messages are added to the ValidationSummary (contained within the ModalPopup) and the ModalPopup is displayed again. When the ValidationSummary's are added to the PopupPanel's, the ModalPopups no longer display correctly after a full page postback caused by the "Save" button within the second PopupPanel. (the first panel continues to function correctly) Both PopupPanels are displayed, and neither is "Popped-Up", they are displayed in-line. Any ideas on how to solve this? Image of Error State (after "PostBack Popup2" button has been clicked) ASPX markup <asp:ScriptManager ID="ScriptManager1" runat="server"> </asp:ScriptManager> <%--********************************************************************* Popup1 *********************************************************************--%> <asp:UpdatePanel ID="Popup1ShowButtonUpdatePanel" runat="server"> <ContentTemplate> <%--This button will cause a partial page postback and pass a parameter to the Popup1ModalPopup in code behind and call its .Show() method to make it visible--%> <asp:Button ID="Popup1ShowButton" runat="server" Text="Show Popup1" OnClick="Popup1ShowButton_Click" CommandArgument="1" /> </ContentTemplate> </asp:UpdatePanel> <%--Hidden Control is used as ModalPopup's TargetControlID .Usually this is the ID of control that causes the Popup, but we want to control the modal popup from code behind --%> <asp:HiddenField ID="Popup1ModalPopupTargetControl" runat="server" /> <ajax:ModalPopupExtender ID="Popup1ModalPopup" runat="server" TargetControlID="Popup1ModalPopupTargetControl" PopupControlID="Popup1PopupControl" CancelControlID="Popup1CancelButton"> </ajax:ModalPopupExtender> <asp:Panel ID="Popup1PopupControl" runat="server" CssClass="ModalPopup" Style="width: 600px; background-color: #FFFFFF; border: solid 1px #000000;"> <%--This button causes validation and a full-page post back. Full page postback will causes the ModalPopup to be Hid. If there are errors in code behind, the code behind will add a message to the ValidationSummary, and make the ModalPopup visible again--%> <asp:Button ID="Popup1PostBackButton" runat="server" Text="PostBack Popup1" OnClick="Popup1PostBackButton_Click" />&nbsp; <asp:Button ID="Popup1CancelButton" runat="server" Text="Cancel Popup1" /> <asp:UpdatePanel ID="Popup1UpdatePanel" runat="server"> <ContentTemplate> <%--*************ISSUE HERE*************** The two ValidationSummary's are causing an issue. When the second ModalPopup's PostBack button is clicked, Both ModalPopup's become visible, but neither are "Popped-Up". If ValidationSummary's are removed, both ModalPopups Function Correctly--%> <asp:ValidationSummary ID="Popup1ValidationSummary" runat="server" /> <%--Will display dynamically passed paramter during partial page post-back--%> Popup1 Parameter:<asp:Literal ID="Popup1Parameter" runat="server"></asp:Literal><br /> </ContentTemplate> </asp:UpdatePanel> &nbsp;<br /> &nbsp;<br /> &nbsp;<br /> </asp:Panel> &nbsp;<br /> &nbsp;<br /> &nbsp;<br /> <%--********************************************************************* Popup2 *********************************************************************--%> <asp:UpdatePanel ID="Popup2ShowButtonUpdatePanel" runat="server"> <ContentTemplate> <%--This button will cause a partial page postback and pass a parameter to the Popup2ModalPopup in code behind and call its .Show() method to make it visible--%> <asp:Button ID="Popup2ShowButton" runat="server" Text="Show Popup2" OnClick="Popup2ShowButton_Click" CommandArgument="2" /> </ContentTemplate> </asp:UpdatePanel> <%--Hidden Control is used as ModalPopup's TargetControlID .Usually this is the ID of control that causes the Popup, but we want to control the modal popup from code behind --%> <asp:HiddenField ID="Popup2ModalPopupTargetControl" runat="server" /> <ajax:ModalPopupExtender ID="Popup2ModalPopup" runat="server" TargetControlID="Popup2ModalPopupTargetControl" PopupControlID="Popup2PopupControl" CancelControlID="Popup2CancelButton"> </ajax:ModalPopupExtender> <asp:Panel ID="Popup2PopupControl" runat="server" CssClass="ModalPopup" Style="width: 600px; background-color: #FFFFFF; border: solid 1px #000000;"> <%--This button causes validation and a full-page post back. Full page postback will causes the ModalPopup to be Hid. If there are errors in code behind, the code behind will add a message to the ValidationSummary, and make the ModalPopup visible again--%> <asp:Button ID="Popup2PostBackButton" runat="server" Text="PostBack Popup2" OnClick="Popup2PostBackButton_Click" />&nbsp; <asp:Button ID="Popup2CancelButton" runat="server" Text="Cancel Popup2" /> <asp:UpdatePanel ID="Popup2UpdatePanel" runat="server"> <ContentTemplate> <%--*************ISSUE HERE*************** The two ValidationSummary's are causing an issue. When the second ModalPopup's PostBack button is clicked, Both ModalPopup's become visible, but neither are "Popped-Up". If ValidationSummary's are removed, both ModalPopups Function Correctly--%> <asp:ValidationSummary ID="Popup2ValidationSummary" runat="server" /> <%--Will display dynamically passed paramter during partial page post-back--%> Popup2 Parameter:<asp:Literal ID="Popup2Parameter" runat="server"></asp:Literal><br /> </ContentTemplate> </asp:UpdatePanel> &nbsp;<br /> &nbsp;<br /> &nbsp;<br /> </asp:Panel> Code Behind protected void Popup1ShowButton_Click(object sender, EventArgs e) { Button btn = sender as Button; //Dynamically pass parameter to ModalPopup during partial page postback Popup1Parameter.Text = btn.CommandArgument; Popup1ModalPopup.Show(); } protected void Popup1PostBackButton_Click(object sender, EventArgs e) { //if there is an error, add a message to the validation summary and //show the ModalPopup again //TODO: add message to validation summary //show ModalPopup after page refresh (request/response) Popup1ModalPopup.Show(); } protected void Popup2ShowButton_Click(object sender, EventArgs e) { Button btn = sender as Button; //Dynamically pass parameter to ModalPopup during partial page postback Popup2Parameter.Text = btn.CommandArgument; Popup2ModalPopup.Show(); } protected void Popup2PostBackButton_Click(object sender, EventArgs e) { //***********After This is when the issue appears********************** //if there is an error, add a message to the validation summary and //show the ModalPopup again //TODO: add message to validation summary //show ModalPopup after page refresh (request/response) Popup2ModalPopup.Show(); }

    Read the article

  • inflate vs findViewById

    - by Cedric
    Hi all, Suppose I have a simple layout xml like the following: button.xml: Are there any differences in the following calls? and which one should i use? button = (Button) getLayoutInflater().inflate(R.layout.button, null); and View v = getLayoutInflater().inflate(R.layout.button, null); button = (Button) v.findViewById(R.id.button01);

    Read the article

  • Use mouse wheel with numpad using ahk?

    - by MrSnipyCat
    I'm on a laptop without a mouse. This means I don't have the middle mouse button/wheel. I tried to use ahk to make my numpad act like a mouse wheel with the middle mouse button. Numpad8::WheelUp Numpad2::WheelDown Numpad5::MButton The problem is that it scrolls up/down 2 times (when I click and release the button). How do I make the wheel scroll only once when I hit the button and not again after releasing it?

    Read the article

  • Ubuntu: Copy terminal mouse selection automatically to clipboard for other apps?

    - by mfn
    I can use keyboard shortcuts and selecting text with the left mouse button allows me to insert the selection within gnome-terminal with the middle mouse button. However, mouse selection with left button does not copy it to the clipboard and thus is not available to other apps. I don't want to use the keyboard shortcuts when I select text with the left mouse button, I want to automatically have it in the clipboard (much like putty works on Windows).

    Read the article

  • How can I add a previous button to this Jquery Content Slider?

    - by user1269988
    I did this nice tutorial for a Jquery Content Slider: http://brenelz.com/blog/build-a-content-slider-with-jquery/ Here is my test page: http://www.gregquinn.com/oneworld/brenez_slider_test.html But the Left button is hidden on the first slide and I do not want it to be. I don't know much about jquery but I tried to set the left button from opacity o to 100 or 1 and it didn't work the button showed up once but did not work. Does anyone know how to do this? Here is the code: (function($) { $.fn.ContentSlider = function(options) { var defaults = { leftBtn : 'images/panel_previous_btn.gif', rightBtn : 'images/panel_next_btn.gif', width : '900px', height : '400px', speed : 400, easing : 'easeOutQuad', textResize : false, IE_h2 : '26px', IE_p : '11px' } var defaultWidth = defaults.width; var o = $.extend(defaults, options); var w = parseInt(o.width); var n = this.children('.cs_wrapper').children('.cs_slider').children('.cs_article').length; var x = -1*w*n+w; // Minimum left value var p = parseInt(o.width)/parseInt(defaultWidth); var thisInstance = this.attr('id'); var inuse = false; // Prevents colliding animations function moveSlider(d, b) { var l = parseInt(b.siblings('.cs_wrapper').children('.cs_slider').css('left')); if(isNaN(l)) { var l = 0; } var m = (d=='left') ? l-w : l+w; if(m<=0&&m>=x) { b .siblings('.cs_wrapper') .children('.cs_slider') .animate({ 'left':m+'px' }, o.speed, o.easing, function() { inuse=false; }); if(b.attr('class')=='cs_leftBtn') { var thisBtn = $('#'+thisInstance+' .cs_leftBtn'); var otherBtn = $('#'+thisInstance+' .cs_rightBtn'); } else { var thisBtn = $('#'+thisInstance+' .cs_rightBtn'); var otherBtn = $('#'+thisInstance+' .cs_leftBtn'); } if(m==0||m==x) { thisBtn.animate({ 'opacity':'0' }, o.speed, o.easing, function() { thisBtn.hide(); }); } if(otherBtn.css('opacity')=='0') { otherBtn.show().animate({ 'opacity':'1' }, { duration:o.speed, easing:o.easing }); } } } function vCenterBtns(b) { // Safari and IE don't seem to like the CSS used to vertically center // the buttons, so we'll force it with this function var mid = parseInt(o.height)/2; b .find('.cs_leftBtn img').css({ 'top':mid+'px', 'padding':0 }).end() .find('.cs_rightBtn img').css({ 'top':mid+'px', 'padding':0 }); } return this.each(function() { $(this) // Set the width and height of the div to the defined size .css({ width:o.width, height:o.height }) // Add the buttons to move left and right .prepend('<a href="#" class="cs_leftBtn"><img src="'+o.leftBtn+'" /></a>') .append('<a href="#" class="cs_rightBtn"><img src="'+o.rightBtn+'" /></a>') // Dig down to the article div elements .find('.cs_article') // Set the width and height of the div to the defined size .css({ width:o.width, height:o.height }) .end() // Animate the entrance of the buttons .find('.cs_leftBtn') .css('opacity','0') .hide() .end() .find('.cs_rightBtn') .hide() .animate({ 'width':'show' }); // Resize the font to match the bounding box if(o.textResize===true) { var h2FontSize = $(this).find('h2').css('font-size'); var pFontSize = $(this).find('p').css('font-size'); $.each(jQuery.browser, function(i) { if($.browser.msie) { h2FontSize = o.IE_h2; pFontSize = o.IE_p; } }); $(this).find('h2').css({ 'font-size' : parseFloat(h2FontSize)*p+'px', 'margin-left' : '66%' }); $(this).find('p').css({ 'font-size' : parseFloat(pFontSize)*p+'px', 'margin-left' : '66%' }); $(this).find('.readmore').css({ 'font-size' : parseFloat(pFontSize)*p+'px', 'margin-left' : '66%' }); } // Store a copy of the button in a variable to pass to moveSlider() var leftBtn = $(this).children('.cs_leftBtn'); leftBtn.bind('click', function() { if(inuse===false) { inuse = true; moveSlider('right', leftBtn); } return false; // Keep the link from firing }); // Store a copy of the button in a variable to pass to moveSlider() var rightBtn = $(this).children('.cs_rightBtn'); rightBtn.bind('click', function() { if(inuse===false) { inuse=true; moveSlider('left', rightBtn); } return false; // Keep the link from firing }); }); } })(jQuery)

    Read the article

  • WebLogic Scripting Tool Tip &ndash; relax the syntax with the easy button

    - by james.bayer
    I stumbled on to this feature in WLST tonight called easeSyntax.  Apparently it’s a hidden feature that one of the WebLogic support engineers blogged about that allows you to simplify the commands in the interactive mode to have fewer parentheses and quotes.  For example, see how some of the commands instead of typing “ls()” I can type '”ls” or “cd(“/somepath”)” can become “cd /somepath”.  It’s not going to save the world, but it will help cut down on some extra typing. The example I was researching when stumbling into this was for how to print the runtime status of deployed application named “hello” on the “AdminServer”.  See the below output. wls:/base_domain/domainConfig> easeSyntax()   You have chosen to ease syntax for some WLST commands. However, the easy syntax should be strictly used in interactive mode. Easy syntax will not function properly in script mode and when used in loops. You can still use the regular jython syntax although you have opted for easy syntax. Use easeSyntax to turn this off. Use help(easeSyntax) for commands that support easy syntax wls:/base_domain/domainConfig> domainRuntime   wls:/base_domain/domainRuntime> ls dr-- AppRuntimeStateRuntime dr-- CoherenceServerLifeCycleRuntimes dr-- ConsoleRuntime dr-- DeployerRuntime dr-- DeploymentManager dr-- DomainServices dr-- LogRuntime dr-- MessageDrivenControlEJBRuntime dr-- MigratableServiceCoordinatorRuntime dr-- MigrationDataRuntimes dr-- PolicySubjectManagerRuntime dr-- SNMPAgentRuntime dr-- ServerLifeCycleRuntimes dr-- ServerRuntimes dr-- ServerServices dr-- ServiceMigrationDataRuntimes   -r-- ActivationTime Wed Dec 15 22:37:02 PST 2010 -r-- MessageDrivenControlEJBRuntime null -r-- MigrationDataRuntimes null -r-- Name base_domain -rw- Parent null -r-- ServiceMigrationDataRuntimes null -r-- Type DomainRuntime   -r-x preDeregister Void : -r-x restartSystemResource Void : WebLogicMBean(weblogic.management.configuration.SystemResourceMBean)   wls:/base_domain/domainRuntime> cd AppRuntimeStateRuntime/AppRuntimeStateRuntime wls:/base_domain/domainRuntime/AppRuntimeStateRuntime/AppRuntimeStateRuntime> ls   -r-- ApplicationIds java.lang.String[active-cache#[email protected], coherence-web-spi#[email protected], coherence#3. -r-- Name AppRuntimeStateRuntime -r-- Type AppRuntimeStateRuntime   -r-x getCurrentState String : String(appid),String(moduleid),String(subModuleId),String(target) -r-x getCurrentState String : String(appid),String(moduleid),String(target) -r-x getCurrentState String : String(appid),String(target) -r-x getIntendedState String : String(appid) -r-x getIntendedState String : String(appid),String(target) -r-x getModuleIds String[] : String(appid) -r-x getModuleTargets String[] : String(appid),String(moduleid) -r-x getModuleTargets String[] : String(appid),String(moduleid),String(subModuleId) -r-x getModuleType String : String(appid),String(moduleid) -r-x getRetireTimeMillis Long : String(appid) -r-x getRetireTimeoutSeconds Integer : String(appid) -r-x getSubmoduleIds String[] : String(appid),String(moduleid) -r-x isActiveVersion Boolean : String(appid) -r-x isAdminMode Boolean : String(appid),String(java.lang.String) -r-x preDeregister Void :   wls:/base_domain/domainRuntime/AppRuntimeStateRuntime/AppRuntimeStateRuntime> cmo.getCurrentState('hello','AdminServer') 'STATE_ACTIVE' wls:/base_domain/domainRuntime/AppRuntimeStateRuntime/AppRuntimeStateRuntime> cd / wls:/base_domain/domainRuntime>

    Read the article

  • Why is my RAID /dev/md1 showing up as /dev/md126? Is mdadm.conf being ignored?

    - by mmorris
    I created a RAID with: sudo mdadm --create --verbose /dev/md1 --level=mirror --raid-devices=2 /dev/sdb1 /dev/sdc1 sudo mdadm --create --verbose /dev/md2 --level=mirror --raid-devices=2 /dev/sdb2 /dev/sdc2 sudo mdadm --detail --scan returns: ARRAY /dev/md1 metadata=1.2 name=ion:1 UUID=aa1f85b0:a2391657:cfd38029:772c560e ARRAY /dev/md2 metadata=1.2 name=ion:2 UUID=528e5385:e61eaa4c:1db2dba7:44b556fb Which I appended it to /etc/mdadm/mdadm.conf, see below: # mdadm.conf # # Please refer to mdadm.conf(5) for information about this file. # # by default (built-in), scan all partitions (/proc/partitions) and all # containers for MD superblocks. alternatively, specify devices to scan, using # wildcards if desired. #DEVICE partitions containers # auto-create devices with Debian standard permissions CREATE owner=root group=disk mode=0660 auto=yes # automatically tag new arrays as belonging to the local system HOMEHOST <system> # instruct the monitoring daemon where to send mail alerts MAILADDR root # definitions of existing MD arrays # This file was auto-generated on Mon, 29 Oct 2012 16:06:12 -0500 # by mkconf $Id$ ARRAY /dev/md1 metadata=1.2 name=ion:1 UUID=aa1f85b0:a2391657:cfd38029:772c560e ARRAY /dev/md2 metadata=1.2 name=ion:2 UUID=528e5385:e61eaa4c:1db2dba7:44b556fb cat /proc/mdstat returns: Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10] md2 : active raid1 sdb2[0] sdc2[1] 208629632 blocks super 1.2 [2/2] [UU] md1 : active raid1 sdb1[0] sdc1[1] 767868736 blocks super 1.2 [2/2] [UU] unused devices: <none> ls -la /dev | grep md returns: brw-rw---- 1 root disk 9, 1 Oct 30 11:06 md1 brw-rw---- 1 root disk 9, 2 Oct 30 11:06 md2 So I think all is good and I reboot. After the reboot, /dev/md1 is now /dev/md126 and /dev/md2 is now /dev/md127????? sudo mdadm --detail --scan returns: ARRAY /dev/md/ion:1 metadata=1.2 name=ion:1 UUID=aa1f85b0:a2391657:cfd38029:772c560e ARRAY /dev/md/ion:2 metadata=1.2 name=ion:2 UUID=528e5385:e61eaa4c:1db2dba7:44b556fb cat /proc/mdstat returns: Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10] md126 : active raid1 sdc2[1] sdb2[0] 208629632 blocks super 1.2 [2/2] [UU] md127 : active (auto-read-only) raid1 sdb1[0] sdc1[1] 767868736 blocks super 1.2 [2/2] [UU] unused devices: <none> ls -la /dev | grep md returns: drwxr-xr-x 2 root root 80 Oct 30 11:18 md brw-rw---- 1 root disk 9, 126 Oct 30 11:18 md126 brw-rw---- 1 root disk 9, 127 Oct 30 11:18 md127 All is not lost, I: sudo mdadm --stop /dev/md126 sudo mdadm --stop /dev/md127 sudo mdadm --assemble --verbose /dev/md1 /dev/sdb1 /dev/sdc1 sudo mdadm --assemble --verbose /dev/md2 /dev/sdb2 /dev/sdc2 and verify everything: sudo mdadm --detail --scan returns: ARRAY /dev/md1 metadata=1.2 name=ion:1 UUID=aa1f85b0:a2391657:cfd38029:772c560e ARRAY /dev/md2 metadata=1.2 name=ion:2 UUID=528e5385:e61eaa4c:1db2dba7:44b556fb cat /proc/mdstat returns: Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10] md2 : active raid1 sdb2[0] sdc2[1] 208629632 blocks super 1.2 [2/2] [UU] md1 : active raid1 sdb1[0] sdc1[1] 767868736 blocks super 1.2 [2/2] [UU] unused devices: <none> ls -la /dev | grep md returns: brw-rw---- 1 root disk 9, 1 Oct 30 11:26 md1 brw-rw---- 1 root disk 9, 2 Oct 30 11:26 md2 So once again, I think all is good and I reboot. Again, after the reboot, /dev/md1 is /dev/md126 and /dev/md2 is /dev/md127????? sudo mdadm --detail --scan returns: ARRAY /dev/md/ion:1 metadata=1.2 name=ion:1 UUID=aa1f85b0:a2391657:cfd38029:772c560e ARRAY /dev/md/ion:2 metadata=1.2 name=ion:2 UUID=528e5385:e61eaa4c:1db2dba7:44b556fb cat /proc/mdstat returns: Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10] md126 : active raid1 sdc2[1] sdb2[0] 208629632 blocks super 1.2 [2/2] [UU] md127 : active (auto-read-only) raid1 sdb1[0] sdc1[1] 767868736 blocks super 1.2 [2/2] [UU] unused devices: <none> ls -la /dev | grep md returns: drwxr-xr-x 2 root root 80 Oct 30 11:42 md brw-rw---- 1 root disk 9, 126 Oct 30 11:42 md126 brw-rw---- 1 root disk 9, 127 Oct 30 11:42 md127 What am I missing here?

    Read the article

  • Glade: How can I set the value of a spin button?

    - by espectalll123
    I've done some spin buttons with Glade for my Python/GTK3 app, but I don't know how to set things like default, lower or higher value. How can I do it? Using the following things for development: Python 2.7.3 GTK 3 Glade 3.12.1 1) I need to change things from script, as I need to set default value and maximum value as a variable; 2) I saw the PyGTK documentation before, it's not working for GTK3; 3) please don't direct me to the GTK3 docummentation... I can't understand it :P

    Read the article

  • How do you force Ubuntu to unmount a disk when you press the eject button on an optical drive?

    - by Michael Curran
    When upgrading my hardware, I also upgraded to Ubuntu 10.10. On my previous system (with 10.04 and earlier) when I ejected a disk from the optical drive, the subfolder in the /media directory was automatically removed. In my new 10.10 system, if I don't eject the disk using the "eject" command within the system, the disk remains mounted, even after a new disk is installed. The new drive is a Blu Ray drive, but I haven't noticed any other problems from it. Normally, this isn't a problem, but it makes installing applications that are spread over multiple CDs more difficult in many cases (i.e. Wine). Any advice?

    Read the article

  • DNS settings for resolving Host name to IP not working?

    - by Hasas Ali Khan
    I want to access my IIS hosted application over LAN. First I installed a DNS server. The DNS configuration steps are: Go to DNS Manager - right click on System Name - click on configure a DNS Server. DNS Server wizard open -, click on next button - Select radio button "forward lookup zone" click on next button. In the second window. click on radio button "The server maintains the zone" and then click next. Give the zone name "example.com" Click on radio button, "Do Not allow dynamic updates". and then click next button. In the next window, click on radio button "No it should not forward query" and then click next button. Complete the configure a DNS server wizard and then click on finish button. After it is managing the DNS records: In DNS server wizard. open tree of forward lookup zone and right click on the new zone name "example.com" - properties and click on "Start of authority" and write values on text boxes serial number=1 primary server=systemname.domainname responsible person=hostmaster.domainname Click on server name, highlight domain name, click on edit button and enter IP address of the server where I host my application. Highlight new zone name and right click on it and click "New Host" option. In this window there are three text boxes: Name(user parent name if blank)=scoring Fully Qualified Domain Name=scoring.example.com IP Address= My IP Address and check on "Create associated pointer(PTR) record" and click on "Add Host" Host button and then click done button. I have host header for my application is "scoring" on port 80 and its working fine on server my application setting are I have change its, Advance setting --> Application Pool Identity --> Local System application can access on server with host name "scoring" but it can not access on machines on LAN. When I change LAN machine host file that is under, C:/windows/system32/driver/etc/host and edit it and enter host name with hosted machine IP like this: scoring 192.168.1.20 By making these changes I can run the application over LAN machines as I mentioned above DNS setting by which I can run App over LAN with out editing the client's host file. What mistake am I doing in this configuration?

    Read the article

  • How do you forcibly unmount a disk when you press the eject button on an optical drive?

    - by Michael Curran
    When upgrading my hardware, I also upgraded to Ubuntu 10.10. On my previous system (with 10.04 and earlier) when I ejected a disk from the optical drive, the subfolder in the /media directory was automatically removed. In my new 10.10 system, if I don't eject the disk using the "eject" command within the system, the disk remains mounted, even after a new disk is installed. The new drive is a Blu Ray drive, but I haven't noticed any other problems from it. Normally, this isn't a problem, but it makes installing applications that are spread over multiple CDs more difficult in many cases (i.e. Wine). Any advice?

    Read the article

  • How do I disable window move with alt + left mouse button in GNOME Shell?

    - by artfulrobot
    There are lots of posts on this about Unity, this is about gnome-shell As with other posters, I use apps (Inkscape in particular) that uses Alt-Click and Alt-drag. Gnome-shell is grabbing this off me and thus disabling features in the application. I have tried using ccsm's Move plugin - you can turn this off and you still get Alt-drag window moving. using gconf editor to change /apps/metacity/general/mouse_button_modifier - this has no effect AFAICS. It's really hindering me. Otherwise I find gnome-shell a really productive environment.

    Read the article

  • How to remove username from "Me" menu (right near to power button on the top panel)? [closed]

    - by Ivan
    Possible Duplicate: How do I replace the MeMenu username with my actual name? My user name takes approximately as long as would 6 icons. I don't need to see my username, I am the only user of my computer. How can I remove it? I use Ubuntu 10.10. UPDATE: The answer found: gconftool -s /system/indicator/me/display --type int 0 UPDATE: Unfortunately the solution doesn't work any more. Now it totally removes the instant messaging menu (including the icon) instead of just removing a name.

    Read the article

  • DataForm commit button is not enabled when data changed.

    - by Grayson Mitchell
    This is a weird problem. I am using a dataform, and when I edit the data the save button is enabled, but the cancel button is not. After looking around a bit I have found that I have to implement the IEditableObject in order to cancel an edit. Great I did that (and it all works), but now the commit button (Save) is grayed out, lol. Anyone have any idea's why the commit button will not activate any more? Xaml <df:DataForm x:Name="_dataForm" AutoEdit="False" AutoCommit="False" CommandButtonsVisibility="All"> <df:DataForm.EditTemplate > <DataTemplate> <StackPanel Name="rootPanel" Orientation="Vertical" df:DataField.IsFieldGroup="True"> <!-- No fields here. They will be added at run-time. --> </StackPanel> </DataTemplate> </df:DataForm.EditTemplate> </df:DataForm> binding DataContext = this; _dataForm.ItemsSource = _rows; ... TextBox textBox = new TextBox(); Binding binding = new Binding(); binding.Path = new PropertyPath("Data"); binding.Mode = BindingMode.TwoWay; binding.Converter = new RowIndexConverter(); binding.ConverterParameter = col.Value.Label; textBox.SetBinding(TextBox.TextProperty, binding); dataField.Content = textBox; // add DataField to layout container rootPanel.Children.Add(dataField); Data Class definition public class Row : INotifyPropertyChanged , IEditableObject { public void BeginEdit() { foreach (var item in _data) { _cache.Add(item.Key, item.Value); } } public void CancelEdit() { _data.Clear(); foreach (var item in _cache) { _data.Add(item.Key, item.Value); } _cache.Clear(); } public void EndEdit() { _cache.Clear(); } private Dictionary<string, object> _cache = new Dictionary<string, object>(); private Dictionary<string, object> _data = new Dictionary<string, object>(); public object this[string index] { get { return _data[index]; } set { _data[index] = value; OnPropertyChanged("Data"); } } public object Data { get { return this; } set { PropertyValueChange setter = value as PropertyValueChange; _data[setter.PropertyName] = setter.Value; } } public event PropertyChangedEventHandler PropertyChanged; protected void OnPropertyChanged(string property) { if (PropertyChanged != null) { PropertyChanged(this, new PropertyChangedEventArgs(property)); } } }

    Read the article

< Previous Page | 98 99 100 101 102 103 104 105 106 107 108 109  | Next Page >