Search Results

Search found 21053 results on 843 pages for 'process'.

Page 105/843 | < Previous Page | 101 102 103 104 105 106 107 108 109 110 111 112  | Next Page >

  • Mercurial CLI is slow in C#?

    - by pATCheS
    I'm writing a utility in C# that will make managing multiple Mercurial repositories easier for the way my team is using it. However, it seems that there is always about a 300 to 400 millisecond delay before I get anything back from hg.exe. I'm using the code below to run hg.exe and hgtk.exe (TortoiseHg's GUI). The code currently includes a Stopwatch and some variables for timing purposes. The delay is roughly the same on multiple runs within the same session. I have also tried specifying the exact path of hg.exe, and got the same result. static string RunCommand(string executable, string path, string arguments) { var psi = new ProcessStartInfo() { FileName = executable, Arguments = arguments, WorkingDirectory = path, UseShellExecute = false, RedirectStandardError = true, RedirectStandardInput = true, RedirectStandardOutput = true, WindowStyle = ProcessWindowStyle.Maximized, CreateNoWindow = true }; var sbOut = new StringBuilder(); var sbErr = new StringBuilder(); var sw = new Stopwatch(); sw.Start(); var process = Process.Start(psi); TimeSpan firstRead = TimeSpan.Zero; process.OutputDataReceived += (s, e) => { if (firstRead == TimeSpan.Zero) { firstRead = sw.Elapsed; } sbOut.Append(e.Data); }; process.ErrorDataReceived += (s, e) => sbErr.Append(e.Data); process.BeginOutputReadLine(); process.BeginErrorReadLine(); var eventsStarted = sw.Elapsed; process.WaitForExit(); var processExited = sw.Elapsed; sw.Reset(); if (process.ExitCode != 0 || sbErr.Length > 0) { Error.Mercurial(process.ExitCode, sbOut.ToString(), sbErr.ToString()); } return sbOut.ToString(); } Any ideas on how I can speed things up? As it is, I'm going to have to do a lot of caching in addition to threading to keep the UI snappy.

    Read the article

  • How to customize the process employed by WCF when serializing contract method arguments?

    - by mark
    Dear ladies and sirs. I would like to formulate a contrived scenario, which nevertheless has firm actual basis. Imagine a collection type COuter, which is a wrapper around an instance of another collection type CInner. Both implement IList (never mind the T). Furthermore, a COuter instance is buried inside some object graph, the root of which (let us refer to it as R) is returned from a WCF service method. My question is how can I customize the WCF serialization process, so that when R is returned, the request to serialize the COuter instance will be routed through my code, which will extract CInner and pass it to the serializer instead. Thus the receiving end still gets R, only no COuter instance is found in the object graph. I hoped that http://stackoverflow.com/questions/2220516/how-does-wcf-serialize-the-method-call will contain the answer, unfortunately the article mentioned there (http://msdn.microsoft.com/en-us/magazine/cc163569.aspx) only barely mentions that advanced serialization scenarios are possible using IDataContractSurrogate interface, but no details are given. I am, on the other hand, would really like to see a working example. Thank you very much in advance.

    Read the article

  • using threads in menu options

    - by vbNewbie
    I have an app that has a console menu with 2/3 selections. One process involves uploading a file and performing a lengthy search process on its contents, whilst another process involves SQL queries and is an interactive process with the user. I wish to use threads to allow one process to run and the menu to offer the option for the second process to run. However you cannot run the first process twice. I have created threads and corrected some compilation errors but the threading options are not working correctly. Any help appreciated. main... Dim tm As Thread = New Thread(AddressOf loadFile) Dim ts As Thread = New Thread(AddressOf reports) .... While Not response.Equals("3") Try Console.Write("Enter choice: ") response = Console.ReadLine() Console.WriteLine() If response.Equals("1") Then Console.WriteLine("Thread 1 doing work") tm.SetApartmentState(ApartmentState.STA) tm.IsBackground = True tm.Start() response = String.Empty ElseIf response.Equals("2") Then Console.WriteLine("Starting a second Thread") ts.Start() response = String.Empty End If ts.Join() tm.Join() Catch ex As Exception errormessage = ex.Message End Try End While I realize that a form based will be easier to implement with perhaps just calling different forms to handle the processes.But I really dont have that option now since the console app will be added to api later. But here are my two processes from the menu functions. Also not sure what to do with the boolean variabel again as suggested below. Private Sub LoadFile() Dim dialog As New OpenFileDialog Dim response1 As String = Nothing Dim filepath As String = Environment.GetFolderPath(Environment.SpecialFolder.MyDocuments) dialog.InitialDirectory = filepath If dialog.ShowDialog() = DialogResult.OK Then fileName = dialog.FileName ElseIf DialogResult.Cancel Then Exit Sub End If Console.ResetColor() Console.Write("Begin Search -- Discovery Search, y or n? ") response1 = Console.ReadLine() If response1 = "y" Then Search() ElseIf response1 = "n" Then Console.Clear() main() End If isRunning = False End Sub and the second one Private Shared Sub report() Dim rptGen As New SearchBlogDiscovery.rptGeneration Console.WriteLine("Tread Process started") rptGen.main() Console.WriteLine("Thread Process ended") isRunning = False End Sub

    Read the article

  • MVC 3, View Model for user registration process. Password validation not working properly

    - by sec_goat
    I am trying to create a user registration page using MVC 3, so that I can better understand the process of how it works, what's going on behind the scenes etc. I am running into some issues when trying to use [Compare] to check to see that the user entered the same password twice. I tried adding the ComparePassword field to my user model first, and found that would not work the way I wanted as I did not have the field in the database, so the obvious answer was to create a View Model using the same information including the ComparePassword field. So I now have created a User model and a RegistrationViewModel, however it appears that the [Compare] on the password is not returning anything, for instance no matter what I put in the two boxes, when I click create it gives no error, which seems to me to mean it was successfully validated. I am not sure what I am doing or not doing to make this work properly. I have tried updating the jQuery.Validate to the newest version as there were some bugs reported in older version, this has not helped my efforts. Below is a wall of code, that is what I am working with. } public class RegistrationViewModel { [Required] [StringLength(15, MinimumLength = 3)] [Display(Name = "User Name")] [RegularExpression(@"(\S)+", ErrorMessage = " White Space is not allowed in User Names")] [ScaffoldColumn(false)] public String Username { get; set; } [Required] [StringLength(15, MinimumLength = 3)] [Display(Name = "First Name")] public String firstName { get; set; } [Required] [StringLength(15, MinimumLength = 3)] [Display(Name = "Last Name")] public String lastName { get; set; } [Required] [Display(Name = "Email")] public String email { get; set; } [Required] [Display(Name = "Password")] [DataType(DataType.Password)] public String password { get; set; } [Required] [DataType(DataType.Password)] [Display(Name = "Re-enter Password")] [Compare("Password", ErrorMessage = "Passwords do not match.")] public String comparePassword { get; set; } }

    Read the article

  • Executing sc.exe from .NET Process unable to start and stop service.

    - by Jason
    I'm trying to restart the service from a remote machine. Here is my code. The problem is that I need to enter startinfo.filename = "sc.exe" since I'm putting "start /wait sc" this is causing an error. Here is my code, any thoughts. Also if anyone has any idea how to keep the cmd window open after this is ran so I could see the code that was ran that would be awesome. string strCommandStop1; string strCommandStop2; string strCommandStart1; string strCommandStart2; string strServer = "\\" + txtServerName.Text; string strDb1 = "SqlAgent$" + txtInsName.Text; string strDb2 = "MSSQL$" + txtInsName.Text; strCommandStop1 = @"start /wait sc " + strServer + " Stop " + strDb1; strCommandStop2 = @"start /wait sc " + strServer + " Stop " + strDb2; strCommandStart1 = @"start /wait sc " + strServer + " Start " + strDb2; strCommandStart2 = @"start /wait sc " + strServer + " Start " + strDb1; try { ProcessStartInfo startInfo = new ProcessStartInfo(); startInfo.CreateNoWindow = true; startInfo.Arguments = strCommandStop1; startInfo.Arguments = strCommandStop2; startInfo.Arguments = strCommandStart1; startInfo.Arguments = strCommandStart2; startInfo .FileName = "sc.exe"; Process.Start(startInfo); } catch (Exception e) { MessageBox.Show(e.Message); }

    Read the article

  • GTK+: How do I process RadioMenuItem choice without marking it chosen? And vise versa

    - by eugene.shatsky
    In my program, I've got a menu with a group of RadioMenuItem entries. Choosing one of them should trigger a function which can either succeed or fail. If it fails, this RadioMenuItem shouldn't be marked chosen (the previous one should persist). Besides, sometimes I want to set marked item without running the choice processing function. Here is my current code: # Update seat menu list def update_seat_menu(self, seats, selected_seat=None): seat_menu = self.builder.get_object('seat_menu') # Delete seat menu items for menu_item in seat_menu: # TODO: is it a good way? does remove() delete obsolete menu_item from memory? if menu_item.__class__.__name__ == 'RadioMenuItem': seat_menu.remove(menu_item) # Fill menu with new items group = [] for seat in seats: menu_item = Gtk.RadioMenuItem.new_with_label(group, str(seat[0])) group = menu_item.get_group() seat_menu.append(menu_item) if str(seat[0]) == selected_seat: menu_item.activate() menu_item.connect("activate", self.choose_seat, str(seat[0])) menu_item.show() # Process item choice def choose_seat(self, entry, seat_name): # Looks like this is called when item is deselected, too; must check if active if entry.get_active(): # This can either succeed or fail self.logind.AttachDevice(seat_name, '/sys'+self.device_syspath, True) Chosen RadioMenuItem gets marked irrespective of the choose_seat() execution result; and the only way to set marked item without triggering choose_seat() is to re-run update_seat_menu() with selected_seat argument, which is an overkill. I tried to connect choose_seat() with 'button-release-event' instead of 'activate' and call entry.activate() in choose_seat() if AttachDevice() succeeds, but this resulted in whole X desktop lockup until AttachDevice() timed out, and chosen item still got marked.

    Read the article

  • Wrong encoding in DataReceivedEventArgs

    - by user2102508
    I start cmd.exe process and redirect stdin to pass script to it and redirect stdout and stderr to read cmd's output. Here is the code of my DataReceivedEventHandler: (o, a) => { if(!String.IsNullOrEmpty(a.Data)) { bw.Write(a.Data.ToUTF8()); bw.Write((byte)'\n'); } } In the code bw is instance of BinaryWriter, ToUTF8 is string extension method, that converts a string to UTF8 encoded byte array. When I use this code in a separate process it works well, however when I use this code as a shared library inside some other process a.Data doesn't contain valid localized characters (like russian characters for example). So how should I convert characters? How to get cmd's OEM encoding? Why does the code works well in a separate process and doesn't work as a shared library inside some other process?

    Read the article

  • Unable to sign in. How to debug?

    - by Dmitriy Budnik
    I had to reboot system with reset button. After reboot I can't sign in. When I enter my password It seems like X-server just restarts. I can sing in as guest and also I can sign in in text TTY. Here is first 150 lines of my lightdm.log: [+0.04s] DEBUG: Logging to /var/log/lightdm/lightdm.log [+0.04s] DEBUG: Starting Light Display Manager 1.2.1, UID=0 PID=1070 [+0.04s] DEBUG: Loaded configuration from /etc/lightdm/lightdm.conf [+0.04s] DEBUG: Using D-Bus name org.freedesktop.DisplayManager [+0.04s] DEBUG: Registered seat module xlocal [+0.04s] DEBUG: Registered seat module xremote [+0.04s] DEBUG: Adding default seat [+0.04s] DEBUG: Starting seat [+0.04s] DEBUG: Starting new display for automatic login as user dmytro [+0.04s] DEBUG: Starting local X display [+3.64s] DEBUG: X server :0 will replace Plymouth [+3.66s] DEBUG: Using VT 7 [+3.66s] DEBUG: Activating VT 7 [+3.66s] DEBUG: Logging to /var/log/lightdm/x-0.log [+3.66s] DEBUG: Writing X server authority to /var/run/lightdm/root/:0 [+3.66s] DEBUG: Launching X Server [+3.66s] DEBUG: Launching process 1154: /usr/bin/X :0 -auth /var/run/lightdm/root/:0 -nolisten tcp vt7 -novtswitch -background none [+3.66s] DEBUG: Waiting for ready signal from X server :0 [+3.66s] DEBUG: Acquired bus name org.freedesktop.DisplayManager [+3.66s] DEBUG: Registering seat with bus path /org/freedesktop/DisplayManager/Seat0 [+10.78s] DEBUG: Got signal 10 from process 1154 [+10.78s] DEBUG: Got signal from X server :0 [+10.78s] DEBUG: Stopping Plymouth, X server is ready [+10.80s] DEBUG: Connecting to XServer :0 [+10.80s] DEBUG: Automatically logging in user dmytro [+10.80s] DEBUG: Started session 1303 with service 'lightdm-autologin', username 'dmytro' [+13.22s] DEBUG: Session 1303 authentication complete with return value 0: Success [+13.26s] DEBUG: Autologin user dmytro authorized [+13.27s] DEBUG: Autologin using session ubuntu [+14.44s] DEBUG: Dropping privileges to uid 1000 [+14.48s] DEBUG: Restoring privileges [+14.49s] DEBUG: Dropping privileges to uid 1000 [+14.49s] DEBUG: Writing /home/dmytro/.dmrc [+14.61s] DEBUG: Restoring privileges [+14.81s] DEBUG: Starting session ubuntu as user dmytro [+14.81s] DEBUG: Session 1303 running command /usr/sbin/lightdm-session gnome-session --session=ubuntu [+15.76s] DEBUG: New display ready, switching to it [+15.76s] DEBUG: Activating VT 7 [+15.76s] DEBUG: Registering session with bus path /org/freedesktop/DisplayManager/Session0 [+16.63s] DEBUG: Session 1303 exited with return value 0 [+16.63s] DEBUG: User session quit [+16.63s] DEBUG: Stopping display [+16.63s] DEBUG: Sending signal 15 to process 1154 [+17.19s] DEBUG: Process 1154 exited with return value 0 [+17.19s] DEBUG: X server stopped [+17.19s] DEBUG: Removing X server authority /var/run/lightdm/root/:0 [+17.19s] DEBUG: Releasing VT 7 [+17.19s] DEBUG: Display server stopped [+17.19s] DEBUG: Display stopped [+17.19s] DEBUG: Active display stopped, switching to greeter [+17.19s] DEBUG: Switching to greeter [+17.19s] DEBUG: Starting new display for greeter [+17.19s] DEBUG: Starting local X display [+17.19s] DEBUG: Using VT 7 [+17.19s] DEBUG: Logging to /var/log/lightdm/x-0.log [+17.19s] DEBUG: Writing X server authority to /var/run/lightdm/root/:0 [+17.19s] DEBUG: Launching X Server [+17.19s] DEBUG: Launching process 1563: /usr/bin/X :0 -auth /var/run/lightdm/root/:0 -nolisten tcp vt7 -novtswitch [+17.19s] DEBUG: Waiting for ready signal from X server :0 [+17.48s] DEBUG: Got signal 10 from process 1563 [+17.48s] DEBUG: Got signal from X server :0 [+17.48s] DEBUG: Connecting to XServer :0 [+17.48s] DEBUG: Starting greeter [+17.48s] DEBUG: Started session 1575 with service 'lightdm', username 'lightdm' [+17.61s] DEBUG: Session 1575 authentication complete with return value 0: Success [+17.61s] DEBUG: Greeter authorized [+17.61s] DEBUG: Logging to /var/log/lightdm/x-0-greeter.log [+17.68s] DEBUG: Session 1575 running command /usr/lib/lightdm/lightdm-greeter-session /usr/sbin/unity-greeter [+20.86s] DEBUG: Greeter connected version=1.2.1 [+20.86s] DEBUG: Greeter connected, display is ready [+20.86s] DEBUG: New display ready, switching to it [+20.86s] DEBUG: Activating VT 7 [+20.86s] DEBUG: Stopping greeter display being switched from [+24.90s] DEBUG: Greeter start authentication for dmytro [+24.90s] DEBUG: Started session 1746 with service 'lightdm', username 'dmytro' [+25.10s] DEBUG: Session 1746 got 1 message(s) from PAM [+25.10s] DEBUG: Prompt greeter with 1 message(s) [+31.87s] DEBUG: Continue authentication [+33.75s] DEBUG: Session 1746 authentication complete with return value 7: Authentication failure [+33.75s] DEBUG: Authenticate result for user dmytro: Authentication failure [+33.75s] DEBUG: Greeter start authentication for dmytro [+33.75s] DEBUG: Session 1746: Sending SIGTERM [+33.75s] DEBUG: Started session 2264 with service 'lightdm', username 'dmytro' [+33.75s] DEBUG: Session 2264 got 1 message(s) from PAM [+33.75s] DEBUG: Prompt greeter with 1 message(s) [+36.41s] DEBUG: Continue authentication [+36.53s] DEBUG: Session 2264 authentication complete with return value 0: Success [+36.53s] DEBUG: Authenticate result for user dmytro: Success [+36.54s] DEBUG: User dmytro authorized [+36.54s] DEBUG: Greeter requests session ubuntu [+36.54s] DEBUG: Using session ubuntu [+36.54s] DEBUG: Stopping greeter [+36.54s] DEBUG: Session 1575: Sending SIGTERM [+37.41s] DEBUG: Greeter closed communication channel [+37.41s] DEBUG: Session 1575 exited with return value 0 [+37.41s] DEBUG: Greeter quit [+37.42s] DEBUG: Dropping privileges to uid 1000 [+37.42s] DEBUG: Restoring privileges [+37.43s] DEBUG: Dropping privileges to uid 1000 [+37.43s] DEBUG: Writing /home/dmytro/.dmrc [+38.35s] DEBUG: Restoring privileges [+40.37s] DEBUG: Starting session ubuntu as user dmytro [+40.37s] DEBUG: Session 2264 running command /usr/sbin/lightdm-session gnome-session --session=ubuntu [+40.39s] DEBUG: Registering session with bus path /org/freedesktop/DisplayManager/Session1 [+50.78s] DEBUG: Session 2264 exited with return value 0 [+50.78s] DEBUG: User session quit [+50.78s] DEBUG: Stopping display [+50.78s] DEBUG: Sending signal 15 to process 1563 [+51.53s] DEBUG: Process 1563 exited with return value 0 [+51.53s] DEBUG: X server stopped [+51.53s] DEBUG: Removing X server authority /var/run/lightdm/root/:0 [+51.53s] DEBUG: Releasing VT 7 [+51.53s] DEBUG: Display server stopped [+51.53s] DEBUG: Display stopped [+51.53s] DEBUG: Active display stopped, switching to greeter [+51.53s] DEBUG: Switching to greeter [+51.53s] DEBUG: Starting new display for greeter [+51.53s] DEBUG: Starting local X display [+51.53s] DEBUG: Using VT 7 [+51.53s] DEBUG: Logging to /var/log/lightdm/x-0.log [+51.53s] DEBUG: Writing X server authority to /var/run/lightdm/root/:0 [+51.53s] DEBUG: Launching X Server [+51.53s] DEBUG: Launching process 2894: /usr/bin/X :0 -auth /var/run/lightdm/root/:0 -nolisten tcp vt7 -novtswitch [+51.53s] DEBUG: Waiting for ready signal from X server :0 [+51.75s] DEBUG: Got signal 10 from process 2894 [+51.75s] DEBUG: Got signal from X server :0 [+51.75s] DEBUG: Connecting to XServer :0 [+51.75s] DEBUG: Starting greeter [+51.75s] DEBUG: Started session 2898 with service 'lightdm', username 'lightdm' [+51.76s] DEBUG: Session 2898 authentication complete with return value 0: Success [+51.76s] DEBUG: Greeter authorized [+51.76s] DEBUG: Logging to /var/log/lightdm/x-0-greeter.log [+51.76s] DEBUG: Session 2898 running command /usr/lib/lightdm/lightdm-greeter-session /usr/sbin/unity-greeter [+53.26s] DEBUG: Greeter connected version=1.2.1 [+53.26s] DEBUG: Greeter connected, display is ready [+53.26s] DEBUG: New display ready, switching to it [+53.26s] DEBUG: Activating VT 7 [+53.26s] DEBUG: Stopping greeter display being switched from [+54.17s] DEBUG: Greeter start authentication for dmytro [+54.17s] DEBUG: Started session 3152 with service 'lightdm', username 'dmytro' [+54.18s] DEBUG: Session 3152 got 1 message(s) from PAM [+54.18s] DEBUG: Prompt greeter with 1 message(s) [+58.61s] DEBUG: Continue authentication [+58.65s] DEBUG: Session 3152 authentication complete with return value 0: Success [+58.65s] DEBUG: Authenticate result for user dmytro: Success [+58.66s] DEBUG: User dmytro authorized [+58.66s] DEBUG: Greeter requests session ubuntu [+58.66s] DEBUG: Using session ubuntu [+58.66s] DEBUG: Stopping greeter [+58.66s] DEBUG: Session 2898: Sending SIGTERM How can I fix it? What other .log files could possibly give me a clue? Update: Possibly it's duplicate of Desktop login fails, terminal works

    Read the article

  • How to launch a Windows service network process to listen to a port on a localhost socket that is vi

    - by rwired
    Here's the code (in a standard TService in Delphi): const ProcessExe = 'MyNetApp.exe'; function RunService: Boolean; var StartInfo : TStartupInfo; ProcInfo : TProcessInformation; CreateOK : Boolean; begin CreateOK := false; FillChar(StartInfo,SizeOf(TStartupInfo),#0); FillChar(ProcInfo,SizeOf(TProcessInformation),#0); StartInfo.cb := SizeOf(TStartupInfo); CreateOK := CreateProcess(nil, PChar(ProcessEXE),nil,nil,False, CREATE_NEW_PROCESS_GROUP+NORMAL_PRIORITY_CLASS, nil, PChar(InstallDir), StartInfo, ProcInfo); CloseHandle(ProcInfo.hProcess); CloseHandle(ProcInfo.hThread); Result := CreateOK; end; procedure TServicel.ServiceExecute(Sender: TService); const IntervalsBetweenRuns = 4; //no of IntTimes between checks IntTime = 250; //ms var Count: SmallInt; begin Count := IntervalsBetweenRuns; //first time run immediately while not Terminated do begin Inc(Count); if Count >= IntervalsBetweenRuns then begin Count := 0; //We check to see if the process is running, //if not we run it. That's all there is to it. //if ProcessEXE crashes, this service host will just rerun it if processExists(ProcessEXE)=0 then RunService; end; Sleep(IntTime); ServiceThread.ProcessRequests(False); end; end; MyNetApp.exe is a SOCKS5 proxy listening on port 9870. Users configure their browser to this proxy which acts as a secure-tunnel/anonymizer. All works perfectly fine on 2000/XP/2003, but on Vista/Win7 with UAC the service runs in Session0 under LocalSystem and port 9870 doesn't show up in netstat for the logged-in user or Administrator. Seems UAC is getting in my way. Is there something I can do with the SECURITY_ATTRIBUTES or CreateProcess, or is there something I can do with CreateProcessAsUser or impersonation to ensure that a network socket on a service is available to logged-in users on the system (note, this app is for mass deployment, I don't have access to user credentials, and require the user elevate their privileges to install a service on Vista/Win7)

    Read the article

  • Can I get a bitmap of an arbitrary window in another application process?

    - by Chris Farmer
    I am trying to automate a third-party Win32 application where I want to capture the graphics content of a particular window at defined time intervals. I am in the early phases of this, and I'm currently trying to use the Microsoft UI Automation API via C# to do most of the interaction between my client app and the external app. I can now get the external app to do what I want it to do, but now I want to capture the graphics from a specific window that seems to be some third-party owner-drawn control. How can I do this? The window I want to capture is the one marked by the red rectangle in this image: I have an implementation that sort of works, but it's dependent on the external app's UI being on top, and that's not guaranteed for me, so I'd prefer to find something more general. var p = Process.Start("c:\myapp.exe"); var mainForm = AutomationElement.FromHandle(p.MainWindowHandle); // "workspace" below is the window whose content I want to capture. var workspace = mainForm.FindFirst(TreeScope.Descendents, new PropertyCondition(AutomationElement.ClassNameProperty, "AfxFrameOrView70u")); var rect = (Rect) workspace.GetCurrentPropertyValue(AutomationElement.BoundingRectangleProperty); using (var bmp = new Bitmap((int)rect.Width, (int)rect.Height)) { using (var g = Graphics.FromImage(bmp)) { g.CopyFromScreen((int)rect.Left, (int)rect.Top, 0, 0, new Size((int)rect.Width, (int)rect.Height)); bmp.Save(@"c:\screenshot.png", ImageFormat.Png); } } The above works well enough when the automated app is on top, but it just blindly copies the screen in the rectangle, so my code is at the mercy of whatever happens to be running on the machine and might cover my app's window. I have read some suggestions to send the WM_PRINT message to the window. This question/answer from a few months back seemed promising, but when I use this code, I just get a white rectangle with none of my control's actual contents. var prop = (int)workspace.GetCurrentPropertyValue(AutomationElement.NativeWindowHandleProperty); var hwnd = new IntPtr(prop); using ( var bmp2 = new Bitmap((int)rect.Width, (int)rect.Height)) { using (Graphics g = Graphics.FromImage(bmp2)) { g.FillRectangle(SystemBrushes.Control, 0, 0, (int)rect.Width, (int)rect.Height); try { SendMessage(hwnd, WM_PRINT, g.GetHdc().ToInt32(), (int)(DrawingOptions.PRF_CHILDREN | DrawingOptions.PRF_CLIENT | DrawingOptions.PRF_OWNED)); } finally { g.ReleaseHdc(); } bmp2.Save(@"c:\screenshot.bmp"); } } So, first, is it even possible for me to reliably save a bitmap of a window's contents? If so, what is the best way, and what is wrong with my WM_PRINT with SendMessage attempt?

    Read the article

  • How can I find out where is my code causing GLib-GObject-CRITICAL

    - by michael
    Hi, When I c/c++ application fails with the following CRITICAL, can you please tell me how can I find out where is the code causing the error? I have tried to run it in Debugger, trying to do a 'bt when the program fails. But it does not show where is the code causing the CRITICAL: (process:3155): GLib-GObject-CRITICAL **: /build/buildd/glib2.0-2.22.3/gobject/gtype.c:2458: initialization assertion failed, use IA__g_type_init() prior to this function (process:3155): GLib-CRITICAL **: g_once_init_leave: assertion `initialization_value != 0' failed (process:3155): GLib-GObject-CRITICAL **: /build/buildd/glib2.0-2.22.3/gobject/gtype.c:2458: initialization assertion failed, use IA__g_type_init() prior to this function (process:3155): GLib-GObject-CRITICAL **: /build/buildd/glib2.0-2.22.3/gobject/gtype.c:2458: initialization assertion failed, use IA__g_type_init() prior to this function (process:3155): GLib-GObject-CRITICAL **: /build/buildd/glib2.0-2.22.3/gobject/gtype.c:2458: initialization assertion failed, use IA__g_type_init() prior to this function (process:3155): GLib-GObject-CRITICAL **: g_type_add_interface_static: assertion `G_TYPE_IS_INSTANTIATABLE (instance_type)' failed (process:3155): GLib-GObject-CRITICAL **: /build/buildd/glib2.0-2.22.3/gobject/gtype.c:2458: initialization assertion failed, use IA__g_type_init() prior to this function Thank you.

    Read the article

  • Can Windows handle inheritance cross the 32-bit/64-bit boundary?

    - by TheBeardyMan
    Is it possible for a child process to inherit a handle from its parent process if one process is 32-bit and the other is 64-bit? HANDLE is a 64 bit type on Win64 and a 32 bit type on Win32, which suggests that even it were supposed to be possible in all cases, there would be some cases where it would fail: a 64-bit parent process, a 32-bit child process, and a handle that can't be represented in 32 bits. Or is naming the object the only way for a 32-bit process and a 64-bit process to get a handle for the same object?

    Read the article

  • Call Babel .Net Obfuscator from C# Code

    - by aron
    Hello, I have a C# WinForms app that I use to create software patches for my app. In noticed that Babel .Net includes Babel.Build.dll and Babel.Code.dll Is there a way, in my C# code, I can call Babel .Net something like: ExecuteCommand(C:\Program Files\Babel\babel.exe "C:\Patch\v6\Demo\Bin\Lib.dll" --rules "C:\Patch\babelRules.xml", 600) Here's a common script to execute a CMD prompt in C#. However if I just include the Babel.Build.dll in my winform I may be able to do it seamlessly. public static int ExecuteCommand(string Command, int Timeout) { int ExitCode; ProcessStartInfo ProcessInfo; Process Process; ProcessInfo = new ProcessStartInfo("cmd.exe", "/C " + Command); ProcessInfo.CreateNoWindow = true; ProcessInfo.UseShellExecute = false; Process = Process.Start(ProcessInfo); Process.WaitForExit(Timeout); ExitCode = Process.ExitCode; Process.Close(); return ExitCode; }

    Read the article

  • Sad logic on types

    - by user2972231
    Code base is littered with code like this: BaseRecord record = // some BaseRecord switch(record.source()) { case FOO: return process((FooRecord)record); case BAR: return process((BarRecord)record); case QUUX: return process((QuuxRecord)record); . . // ~25 more cases . } and then private SomeClass process(BarRecord record) { } private SomeClass process(FooRecord record) { } private SomeClass process(QuuxRecord record) { } It makes me terribly sad. Then, every time a new class is derived from BaseRecord, we have to chase all over our code base updating these case statements and adding new process methods. This kind of logic is repeated everywhere, I think too many to add a method for each and override in the classes. How can I improve this?

    Read the article

  • Linq to xml : can't load all elements

    - by aleo
    hello i'm trying to load some elements from a xml file. but it XDocument.Load seems not treating xml file properly in this case, the method returns the content of the xml file as one node. here is my xml content: <processes> <process>winamp</process> <process>Acrobat</process> <process>WinRAR</process> </processes> and the code that reads the file: XDocument loaded = XDocument.Load("/process_list.xml"); var x = from a in loaded.Descendants("processes") select a.Element("process"); foreach (var t in x) { Console.WritleLine(t.Value.ToString()); } thank you

    Read the article

  • Using Java, can I have one JVM spawn another, and then have the original one exit?

    - by CarlG
    I have a need to have a running JVM start another JVM and then exit. I'm currently trying to do this via Runtime.getRuntime().exec(). The other JVM starts, but my original JVM won't exit until the "child" JVM process stops. It appears that using Runtime.getRuntime().exec() creates a parent-child relationship between the processes. Is there some way to de-couple the spawned process so that the parent can die, or some other mechanism to spawn a process without any relationship to the creating process? Note that this seems exactly like this question: http://stackoverflow.com/questions/2566502/using-java-to-spawn-a-process-and-keep-it-running-after-parent-quits but the accepted answer there doesn't actually work, at least not on my system (Windows 7, Java 5 and 6). It seems that maybe this is a platform-dependent behavior. I'm looking for a platform independent way to reliably invoke the other process and let my original process die.

    Read the article

  • How to get an X11 Window from a Process ID ?

    - by Adam Pierce
    Under Linux, my C++ application is using fork() and execv() to launch multiple instances of OpenOffice so as to view some powerpoint slide shows. This part works. Next I want to be able to move the OpenOffice windows to specific locations on the display. I can do that with the XMoveResizeWindow() function but I need to find the Window for each instance. I have the process ID of each instance, how can I find the X11 Window from that ? UPDATE - Thanks to Andy's suggestion, I have pulled this off. I'm posting the code here to share it with the Stack Overflow community. Unfortunately Open Office does not seem to set the _NET_WM_PID property so this doesn't ultimately solve my problem but it does answer the question. // Attempt to identify a window by name or attribute. // by Adam Pierce <[email protected]> #include <X11/Xlib.h> #include <X11/Xatom.h> #include <iostream> #include <list> using namespace std; class WindowsMatchingPid { public: WindowsMatchingPid(Display *display, Window wRoot, unsigned long pid) : _display(display) , _pid(pid) { // Get the PID property atom. _atomPID = XInternAtom(display, "_NET_WM_PID", True); if(_atomPID == None) { cout << "No such atom" << endl; return; } search(wRoot); } const list<Window> &result() const { return _result; } private: unsigned long _pid; Atom _atomPID; Display *_display; list<Window> _result; void search(Window w) { // Get the PID for the current Window. Atom type; int format; unsigned long nItems; unsigned long bytesAfter; unsigned char *propPID = 0; if(Success == XGetWindowProperty(_display, w, _atomPID, 0, 1, False, XA_CARDINAL, &type, &format, &nItems, &bytesAfter, &propPID)) { if(propPID != 0) { // If the PID matches, add this window to the result set. if(_pid == *((unsigned long *)propPID)) _result.push_back(w); XFree(propPID); } } // Recurse into child windows. Window wRoot; Window wParent; Window *wChild; unsigned nChildren; if(0 != XQueryTree(_display, w, &wRoot, &wParent, &wChild, &nChildren)) { for(unsigned i = 0; i < nChildren; i++) search(wChild[i]); } } }; int main(int argc, char **argv) { if(argc < 2) return 1; int pid = atoi(argv[1]); cout << "Searching for windows associated with PID " << pid << endl; // Start with the root window. Display *display = XOpenDisplay(0); WindowsMatchingPid match(display, XDefaultRootWindow(display), pid); // Print the result. const list<Window> &result = match.result(); for(list<Window>::const_iterator it = result.begin(); it != result.end(); it++) cout << "Window #" << (unsigned long)(*it) << endl; return 0; }

    Read the article

  • How do I process the largest match first in PHP?

    - by animuson
    Ok, so I tried searching around first but I didn't exactly know how to word this question or a search phrase. Let me explain. I have data that looks like this: <!-- data:start --> <!-- 0:start --> <!-- 0:start -->0,9<!-- 0:stop --> <!-- 1:start -->0,0<!-- 1:stop --> <!-- 2:start -->9,0<!-- 2:stop --> <!-- 3:start -->9,9<!-- 3:stop --> <!-- 4:start -->0,9<!-- 4:stop --> <!-- 0:stop --> <!-- 1:start --> <!-- 0:start -->1,5<!-- 0:stop --> <!-- 1:start -->1,6<!-- 1:stop --> <!-- 2:start -->3,6<!-- 2:stop --> <!-- 3:start -->3,8<!-- 3:stop --> <!-- 4:start -->4,8<!-- 4:stop --> <!-- 1:stop --> <!-- 2:start --> <!-- 0:start -->0,7<!-- 0:stop --> <!-- 1:start -->1,7<!-- 1:stop --> <!-- 2:stop --> <!-- data:stop --> So it's basically a bunch of points. Here is the code I'm currently using to try and parse it so that it would create an array like so: Array ( 0 => Array ( 0 => "0,9", 1 => "0,0", 2 => "9,0", 3 => "9,9", 4 => "0,9" ), 1 => Array ( 0 => "1,5", 1 => "1,6", 2 => "3,6", 3 => "3,8", 4 => "4,8" ), 2 => Array ( 0 => "0,7", 1 => "1,7" ) ) However, it is returning an array that looks like this: Array ( 0 => "0,9", 1 => "0,0", 2 => "9,0" ) Viewing the larger array that I have on my screen, you see that it's setting the first instance of that variable when matching. So how do I get it to find the widest match first and then process the insides. Here is the function I am currently using: function explosion($text) { $number = preg_match_all("/(<!-- ([\w]+):start -->)\n?(.*?)\n?(<!-- \\2:stop -->)/s", $text, $matches, PREG_SET_ORDER); if ($number == 0) return $text; else unset($item); foreach ($matches as $item) if (empty($data[$item[2]])) $data[$item[2]] = $this->explosion($item[3]); return $data; } I'm sure it will be something stupid and simple that I've overlooked, but that just makes it an easy answer for you I suppose.

    Read the article

  • Bye Bye Year of the Dragon, Hello BPM

    - by Ajay Khanna
    Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} As 2012 fades and we usher in a New Year, let’s look back at some of the hottest BPM trends and those we’ll be seeing more of in the coming months. BPM is as much about people as it is about technology. As people adopt new ways of engagement, new channels of communications and new devices to interact , the changes are reflected in BPM practices. As Social and Mobile have become an integral part of our personal and professional lives, we’ll see tighter integration of social and mobile with BPM, and more use cases emerging for smarter process management in 2013. And with products and services becoming less differentiated, organizations will strive to differentiate on Customer Experience. Concepts like Pace Layered Architecture and Dynamic Case Management will provide more flexibility and agility to IT groups and knowledge workers. Take a look at some of these capabilities we showcased (see video) at Oracle OpenWorld 2012. Some of these trends that will continue to gain momentum in 2013: Social networks and social media have provided a new way for businesses to engage with customers. A prospect is likely to reach out to their social network before making any purchase. Companies are increasingly engaging with customers in social networks to influence their purchasing decisions, as well as listening to customers via tools like sentiment analysis to see what customers think about a particular product or process. These insights are valuable as companies look to improve their processes. Inside organizations, workers are using social tools to engage with each other to design new products and processes. Social collaboration tools are being used to resolve issues where an employee needs consultation to reach a decision. Oracle BPM Suite includes social interaction as an integral part of its process design and work management to empower today’s business users. Ubiquitous smart mobile devices are trending as a tool of choice for many workers. Many companies are adopting the policy of “Bring Your Own Device,” and the device of choice is a tablet. Devices like smart phones and tablets not only provide mobility to workers and customers, but they also provide additional important information – the context. By integrating the mobile context (location, photos, and preferences) into your processes, organizations can make much more informed decisions, as well as offer more personalized service to customers. Using Oracle ADF Mobile, you can easily create user interfaces for mobile devices and also capture location data for process execution. Customer experience was at the forefront of trending topics in 2012. Organizations are trying to understand their customers better and offer them more personalized and differentiated services. Customer experience is paramount when companies design sales and support processes. Companies are looking to BPM to consistently and efficiently orchestrate customer facing processes across disparate systems, departments and channels of communication. Oracle BPM Suite provides just the right capabilities for organizations to design and deliver an excellent customer experience. Pace Layered Architecture strategy is gaining traction as a way to maximize agility and minimize disruption in organizations. It provides a framework to manage the evolution of your information system when different pieces of it are changing at different rates and need to be updated independent of one another. Oracle Fusion Middleware and Oracle BPM Suite are designed with this in mind. The database layer, integration layer, application layer, and process layer should not be required to change at the same time. Most of the business changes to policy or process can be done at the process layer without disrupting the whole infrastructure. By understanding the type of change needed at a particular level, organizations can become much more agile and efficient. Adaptive Case Management proposes more flexibility to manage processes or cases that do not follow a structured process flow. In such situations, the knowledge worker managing the case needs to evaluate what step should occur next because the sequence of steps can’t be predetermined. Another characteristic is that it requires much more collaboration than straight-through process. As simple processes become automated, and customers adopt more and more self-service, cases that reach the case workers are much more complex and need more investigation. Oracle BPM suite includes comprehensive adaptive case management capability to manage such unstructured and complex processes. Smart BPM or making your BPM intelligent has been the holy grail for BPM practitioners who imagined that one day BPM would become one with Business Intelligence, Business Activity Monitoring and Complex Event Processing, making it much more responsive and helpful in organizational decision making. In 2013, organizations will begin to deploy these intelligent BPM solutions. Oracle offers an integrated solution that brings together the powerful functionality of BI, BAM, event processing, and Real Time Decisions to help organizations create smart process based solutions. In order to help customers reach their BPM goals faster and remove risks associated with BPM initiatives, Oracle has introduced Oracle Process Accelerators, pre-built best practices applications built on Oracle BPM Suite that are fully production grade and ready to deploy. These are exiting times for BPM practitioners and there is so much to look forward to in 2013. We wish you a very happy and prosperous New Year 2013. Happy BPMing!

    Read the article

  • Randomly displayed flashing lines, no response to all shortcuts, just power off. [syslog included]

    - by B. Roland
    Hello! I have an old machine, and I want to use for that to learn employees how to use Ubuntu, and to be easyer to switch from Windows. I've been installed 10.04, and updated, but this strange stuff is happend. Graphical installion failed, same strange thing. With alternate workd. Sometimes, when I boot up, a boot message displayed: Keyboard failure..., often diplayed after reboot, and after shutdown, when I haven't plugged off from AC. I replaced the keyboard yet, same failure... If I powered off, and plugged off from AC, no keyboard problems displayed in boot time. Details Configuration: Dell OptiPlex GX60 - in original cover, no changes. 256 MB DDR 166 MHz Intel® Celeron® Processor 2.40 GHz Dell 0C3207 Base Board I know, that is not enough, but I have three other Nec compuers, with nearly similar config, and they works well with 9.10, 10.04, 10.10. Live CDs I've been tried with 10.04 and 10.10, but the problem is displayed too. With 9.10 no strange things displayed, but it froze, during a simple apt-get install. Syslog An error loop is logged here, but I paste the whole startup and error lines. The flashing lines are displayed sometimes immediately after login, but sometimes after 10 minutes, but once occured, that nothing happend. Strange thing is displayed immediately after login: here. An other boot, after some minutes, strange lines, and loop in log appeard: here. The loop should be that: Jan 23 00:20:08 machine_name kernel: [ 46.782212] [drm:i915_gem_entervt_ioctl] *ERROR* Reenabling wedged hardware, good luck Jan 23 00:20:08 machine_name kernel: [ 47.100033] [drm:i915_hangcheck_elapsed] *ERROR* Hangcheck timer elapsed... GPU hung Jan 23 00:20:08 machine_name kernel: [ 47.100045] render error detected, EIR: 0x00000000 Jan 23 00:20:08 machine_name kernel: [ 47.101487] [drm:i915_do_wait_request] *ERROR* i915_do_wait_request returns -5 (awaiting 16 at 9) Jan 23 00:20:11 machine_name kernel: [ 49.152020] [drm:i915_gem_idle] *ERROR* hardware wedged Jan 23 00:20:11 machine_name gdm-simple-slave[1245]: WARNING: Unable to load file '/etc/gdm/custom.conf': No such file or directory Jan 23 00:20:11 machine_name acpid: client 1239[0:0] has disconnected Jan 23 00:20:11 machine_name acpid: client connected from 1247[0:0] Jan 23 00:20:11 machine_name acpid: 1 client rule loaded UPDATE Added syslog things: before errors, error loop, the complete shutdown(after the big updates): Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Sucessfully called chroot. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Sucessfully dropped privileges. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Sucessfully limited resources. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Running. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Watchdog thread running. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Canary thread running. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Sucessfully made thread 1337 of process 1337 (n/a) owned by '1001' high priority at nice level -11. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Supervising 1 threads of 1 processes of 1 users. Jan 28 20:40:32 machine_name rtkit-daemon[1339]: Sucessfully made thread 1345 of process 1337 (n/a) owned by '1001' RT at priority 5. Jan 28 20:40:32 machine_name rtkit-daemon[1339]: Supervising 2 threads of 1 processes of 1 users. Jan 28 20:40:32 machine_name rtkit-daemon[1339]: Sucessfully made thread 1349 of process 1337 (n/a) owned by '1001' RT at priority 5. Jan 28 20:40:32 machine_name rtkit-daemon[1339]: Supervising 3 threads of 1 processes of 1 users. Jan 28 20:40:37 machine_name pulseaudio[1337]: ratelimit.c: 2 events suppressed Jan 28 20:41:33 machine_name AptDaemon: INFO: Initializing daemon Jan 28 20:41:44 machine_name kernel: [ 167.691563] lo: Disabled Privacy Extensions Jan 28 20:47:33 machine_name AptDaemon: INFO: Quiting due to inactivity Jan 28 20:47:33 machine_name AptDaemon: INFO: Shutdown was requested Jan 28 20:59:50 machine_name kernel: [ 1253.840513] lo: Disabled Privacy Extensions Jan 28 21:17:02 machine_name CRON[1874]: (root) CMD ( cd / && run-parts --report /etc/cron.hourly) Jan 28 21:17:38 machine_name kernel: [ 2321.553239] lo: Disabled Privacy Extensions Jan 28 22:07:44 machine_name kernel: [ 5327.840254] lo: Disabled Privacy Extensions Jan 28 22:17:02 machine_name CRON[2665]: (root) CMD ( cd / && run-parts --report /etc/cron.hourly) Jan 28 22:32:38 machine_name sudo: pam_sm_authenticate: Called Jan 28 22:32:38 machine_name sudo: pam_sm_authenticate: username = [some_user] Jan 28 22:32:38 machine_name sudo: pam_sm_authenticate: /home/some_user is already mounted Jan 28 22:57:03 machine_name kernel: [ 8286.641472] lo: Disabled Privacy Extensions Jan 28 22:57:24 machine_name sudo: pam_sm_authenticate: Called Jan 28 22:57:24 machine_name sudo: pam_sm_authenticate: username = [some_user] Jan 28 22:57:24 machine_name sudo: pam_sm_authenticate: /home/some_user is already mounted Jan 28 23:07:42 machine_name kernel: [ 8925.272030] [drm:i915_hangcheck_elapsed] *ERROR* Hangcheck timer elapsed... GPU hung Jan 28 23:07:42 machine_name kernel: [ 8925.272048] render error detected, EIR: 0x00000000 Jan 28 23:07:42 machine_name kernel: [ 8925.272093] [drm:i915_do_wait_request] *ERROR* i915_do_wait_request returns -5 (awaiting 171453 at 171452) Jan 28 23:07:45 machine_name kernel: [ 8928.868041] [drm:i915_gem_idle] *ERROR* hardware wedged Jan 28 23:08:10 machine_name acpid: client 925[0:0] has disconnected Jan 28 23:08:10 machine_name acpid: client connected from 8127[0:0] Jan 28 23:08:10 machine_name acpid: 1 client rule loaded Jan 28 23:08:11 machine_name kernel: [ 8955.046248] [drm:i915_gem_entervt_ioctl] *ERROR* Reenabling wedged hardware, good luck Jan 28 23:08:12 machine_name kernel: [ 8955.364016] [drm:i915_hangcheck_elapsed] *ERROR* Hangcheck timer elapsed... GPU hung Jan 28 23:08:12 machine_name kernel: [ 8955.364027] render error detected, EIR: 0x00000000 Jan 28 23:08:12 machine_name kernel: [ 8955.364407] [drm:i915_do_wait_request] *ERROR* i915_do_wait_request returns -5 (awaiting 171457 at 171452) Jan 28 23:08:14 machine_name kernel: [ 8957.472025] [drm:i915_gem_idle] *ERROR* hardware wedged Jan 28 23:08:14 machine_name acpid: client 8127[0:0] has disconnected Jan 28 23:08:14 machine_name acpid: client connected from 8141[0:0] Jan 28 23:08:14 machine_name acpid: 1 client rule loaded Jan 28 23:08:15 machine_name kernel: [ 8958.671722] [drm:i915_gem_entervt_ioctl] *ERROR* Reenabling wedged hardware, good luck Jan 28 23:08:15 machine_name kernel: [ 8958.988015] [drm:i915_hangcheck_elapsed] *ERROR* Hangcheck timer elapsed... GPU hung Jan 28 23:08:15 machine_name kernel: [ 8958.988026] render error detected, EIR: 0x00000000 Jan 28 23:08:15 machine_name kernel: [ 8958.989400] [drm:i915_do_wait_request] *ERROR* i915_do_wait_request returns -5 (awaiting 171459 at 171452) Jan 28 23:08:16 machine_name init: tty4 main process (848) killed by TERM signal Jan 28 23:08:16 machine_name init: tty5 main process (856) killed by TERM signal Jan 28 23:08:16 machine_name NetworkManager: nm_signal_handler(): Caught signal 15, shutting down normally. Jan 28 23:08:16 machine_name init: tty2 main process (874) killed by TERM signal Jan 28 23:08:16 machine_name init: tty3 main process (875) killed by TERM signal Jan 28 23:08:16 machine_name init: tty6 main process (877) killed by TERM signal Jan 28 23:08:16 machine_name init: cron main process (890) killed by TERM signal Jan 28 23:08:16 machine_name init: tty1 main process (1146) killed by TERM signal Jan 28 23:08:16 machine_name avahi-daemon[644]: Got SIGTERM, quitting. Jan 28 23:08:16 machine_name avahi-daemon[644]: Leaving mDNS multicast group on interface eth0.IPv4 with address 10.238.11.134. Jan 28 23:08:16 machine_name acpid: exiting Jan 28 23:08:16 machine_name init: avahi-daemon main process (644) terminated with status 255 Jan 28 23:08:17 machine_name kernel: Kernel logging (proc) stopped. Jan 28 23:09:00 machine_name kernel: imklog 4.2.0, log source = /proc/kmsg started. Jan 28 23:09:00 machine_name rsyslogd: [origin software="rsyslogd" swVersion="4.2.0" x-pid="516" x-info="http://www.rsyslog.com"] (re)start Jan 28 23:09:00 machine_name rsyslogd: rsyslogd's groupid changed to 103 Jan 28 23:09:00 machine_name rsyslogd: rsyslogd's userid changed to 101 Jan 28 23:09:00 machine_name rsyslogd-2039: Could no open output file '/dev/xconsole' [try http://www.rsyslog.com/e/2039 ] When I hit the On/Off button, the system shuts down normally. May be it a hardware problem, but I don't know... Can you say something useful to solve my problem?

    Read the article

  • Different Not Automatically Implies Better

    - by Alois Kraus
    Originally posted on: http://geekswithblogs.net/akraus1/archive/2013/11/05/154556.aspxRecently I was digging deeper why some WCF hosted workflow application did consume quite a lot of memory although it did basically only load a xaml workflow. The first tool of choice is Process Explorer or even better Process Hacker (has more options and the best feature copy&paste does work). The three most important numbers of a process with regards to memory are Working Set, Private Working Set and Private Bytes. Working set is the currently consumed physical memory (parts can be shared between processes e.g. loaded dlls which are read only) Private Working Set is the physical memory needed by this process which is not shareable Private Bytes is the number of non shareable which is only visible in the current process (e.g. all new, malloc, VirtualAlloc calls do create private bytes) When you have a bigger workflow it can consume under 64 bit easily 500MB for a 1-2 MB xaml file. This does not look very scalable. Under 64 bit the issue is excessive private bytes consumption and not the managed heap. The picture is quite different for 32 bit which looks a bit strange but it seems that the hosted VB compiler is a lot less memory hungry under 32 bit. I did try to repro the issue with a medium sized xaml file (400KB) which does contain 1000 variables and 1000 if which can be represented by C# code like this: string Var1; string Var2; ... string Var1000; if (!String.IsNullOrEmpty(Var1) ) { Console.WriteLine(“Var1”); } if (!String.IsNullOrEmpty(Var2) ) { Console.WriteLine(“Var2”); } ....   Since WF is based on VB.NET expressions you are bound to the hosted VB.NET compiler which does result in (x64) 140 MB of private bytes which is ca. 140 KB for each if clause which is quite a lot if you think about the actually present functionality. But there is hope. .NET 4.5 does allow now C# expressions for WF which is a major step forward for all C# lovers. I did create some simple patcher to “cross compile” my xaml to C# expressions. Lets look at the result: C# Expressions VB Expressions x86 x86 On my home machine I have only 32 bit which gives you quite exactly half of the memory consumption under 64 bit. C# expressions are 10 times more memory hungry than VB.NET expressions! I wanted to do more with less memory but instead it did consume a magnitude more memory. That is surprising to say the least. The workflow does initialize in about the same time under x64 and x86 where the VB code does it in 2s whereas the C# version needs 18s. Also nearly ten times slower. That is a too high price to pay for any bigger sized xaml workflow to convert from VB.NET to C# expressions. If I do reduce the number of expressions to 500 then it does need 400MB which is about half of the memory. It seems that the cost per if does rise linear with the number of total expressions in a xaml workflow.  Expression Language Cost per IF Startup Time C# 1000 Ifs x64 1,5 MB 18s C# 500 Ifs x64 750 KB 9s VB 1000 Ifs x64 140 KB 2s VB 500 Ifs x64 70 KB 1s Now we can directly compare two MS implementations. It is clear that the VB.NET compiler uses the same underlying structure but it has much higher offset compared to the highly inefficient C# expression compiler. I have filed a connect bug here with a harsher wording about recent advances in memory consumption. The funniest thing is that one MS employee did give an Azure AppFabric demo around early 2011 which was so slow that he needed to investigate with xperf. He was after startup time and the call stacks with regards to VB.NET expression compilation were remarkably similar. In fact I only found this post by googling for parts of my call stacks. … “C# expressions will be coming soon to WF, and that will have different performance characteristics than VB” … What did he know Jan 2011 what I did no know until today? ;-). He knew that C# expression will come but that they will not be automatically have better footprint. It is about time to fix that. In its current state C# expressions are not usable for bigger workflows. That also explains the headline for today. You can cheat startup time by prestarting workflows so that the demo looks nice and snappy but it does hurt scalability a lot since you do need much more memory than necessary. I did find the stacks by enabling virtual allocation tracking within XPerf which is still the best tool out there. But first you need to look at your process to check where the memory is hiding: For the C# Expression compiler you do not need xperf. You can directly dump the managed heap and check with a profiler of your choice. But if the allocations are happening on the Private Data ( VirtualAlloc ) you can find it with xperf. There is a nice video on channel 9 explaining VirtualAlloc tracking it in greater detail. If your data allocations are on the Heap it does mean that the C/C++ runtime did create a heap for you where all malloc, new calls do allocate from it. You can enable heap tracing with xperf and full call stack support as well which is doable via xperf like it is shown also on channel 9. Or you can use WPRUI directly: To make “Heap Usage” it work you need to set for your executable the tracing flags (before you start it). For example devenv.exe HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Image File Execution Options\devenv.exe DWORD TracingFlags 1 Do not forget to disable it after you did complete profiling the process or it will impact the startup time quite a lot. You can with xperf attach directly to a running process and collect heap allocation information from a gone wild process. Very handy if you need to find out what a process was doing which has arrived in a funny state. “VirtualAlloc usage” does work without explicitly enabling stuff for a specific process and is always on machine wide. I had issues on my Windows 7 machines with the call stack collection and the latest Windows 8.1 Performance Toolkit. I was told that WPA from Windows 8.0 should work fine but I do not want to downgrade.

    Read the article

  • Windows shutdown processes termination sequence

    - by jpmartins
    I've seen today an wierd situation. I have a theory, but it would help to know more about the windows shutdown process. If you have some knowlaged about it please share. A machine was shutdown (at this moment I suspect an unexpected mantainace), on that machine there was a long running process that was interrupted. Monitorization confirms that the process did not terminated normally. Loking at the logs for the long running process it seem that was just finishing. That seems higly unprobable since it was running for more than 6 hours (witch is a bit more than the usual 5 hours). The process lanches child processes and waits for results from them, I suspect pour error control on the parent process and that the shutdown as terminated child processes before.

    Read the article

  • New install of Steam not running on new install of Ubuntu 13.10

    - by inferKNOX
    I tried purging steam, un-installing and reinstalling steam, deleting /home/.steam/share/steam/appcache/, deleting everything in /home/.steam/share/steam/ and nothing helped. I installed Ubuntu, then steam into it directly afterward. I installed steam from Ubuntu Software Centre, launched it, it updated 206MB, then closed. When I tried to launch it again, it momentarily flashes the checking for update dialogue, then closes every time. Then (in an unrelated event) Ubuntu said some system updates are necessary and one of them was Steam launcher. I did the update, tried to launch Steam; same story. Really need help on this, as I did a complete re-isntall of Ubuntu, then Steam again and it did not help at all. Here's the log: user@computer:~$ steam Running Steam on ubuntu 13.10 64-bit STEAM_RUNTIME is enabled automatically Installing breakpad exception handler for appid(steam)/version(1381282832_client) Installing breakpad exception handler for appid(steam)/version(1381282832_client) Installing breakpad exception handler for appid(steam)/version(1381282832_client) unlinked 0 orphaned pipes removing stale semaphore last operated on by process 2297 with name 0eBlobRegistryMutex_313E4D748EE12691A95DDE8913185F7E removing stale semaphore last operated on by process 2297 with name 0eBlobRegistrySignal_313E4D748EE12691A95DDE8913185F7E removing stale semaphore last operated on by process 2297 with name 0emSteamEngineInstance removing stale semaphore last operated on by process 2297 with name 0eSteamEngineLock Gtk-Message: Failed to load module "overlay-scrollbar" Gtk-Message: Failed to load module "unity-gtk-module" Installing breakpad exception handler for appid(steam)/version(1381282832_client) Fontconfig error: "/etc/fonts/conf.d/10-scale-bitmap-fonts.conf", line 70: non-double matrix element Fontconfig error: "/etc/fonts/conf.d/10-scale-bitmap-fonts.conf", line 70: non-double matrix element Fontconfig warning: "/etc/fonts/conf.d/10-scale-bitmap-fonts.conf", line 78: saw unknown, expected number [1030/115016:WARNING:proxy_service.cc(958)] PAC support disabled because there is no system implementation Installing breakpad exception handler for appid(steam)/version(1381282832_client) Installing breakpad exception handler for appid(steam)/version(1381282832_client) Installing breakpad exception handler for appid(steam)/version(1381282832_client) Installing breakpad exception handler for appid(steam)/version(1381282832_client) Steam: An X Error occurred X Error of failed request: BadValue (integer parameter out of range for operation) Major opcode of failed request: 18 (X_ChangeProperty) Value in failed request: 0x0 Serial number of failed request: 105 xerror_handler: X failed, continuing Uploading dump (out-of-process) [proxy ''] /tmp/dumps/crash_20131030115012_1.dmp /home/user/.local/share/Steam/steam.sh: line 717: 2650 Segmentation fault (core dumped) $STEAM_DEBUGGER "$STEAMROOT/$PLATFORM/$STEAMEXE" "$@" Finished uploading minidump (out-of-process): success = yes response: CrashID=bp-484ddae7-0b1c-4ae4-be84-42a9c2131030 Thanks in advance.

    Read the article

  • IIS 7 AppPool logs an error after recycle due to inactivity

    - by ddysart
    We have Windows 2008 RS Server running IIS hosting an ASP.NET site. This morning there was a weird sequence. First a notice that the AppPool was being recycled due to inactivity: "A worker process with process id of '6896' serving application pool 'xxxx' was shutdown due to inactivity. Application Pool timeout configuration was set to 20 minutes. A new worker process will be started when needed." This makes sense and jibes with out timeout settings, but 30 seconds later we see: "A process serving application pool 'xxxx' terminated unexpectedly. The process id was '6896'. The process exit code was '0xc0000005'." I found an older KB article that explains a condition where this might happend on IIS6 due to permission issues, but am curious what might cause this on IIS7.5, especially since we are not seeing it regularly.

    Read the article

  • The effects of Agile Programming can alter the five desirable properties of modeling tools and techniques

    The effects of Agile Programming can alter the five desirable properties of modeling tools and techniques as documented by Pfleeger. The agile methodology does promote human understanding and communication through the use of short iterative software development life cycles which forces stakeholders to review the project and adjust the project for any requirement changes.  Due to the consistent evaluations of a project and requirements, process are continually being refined, upgraded, and compared against other alternatives to ensure the best design delivered to the client. Due to the short repetitive development cycles, increased time is devoted to process management due to the fact that requirements and designs could be constantly changing. This requires additional forecasting, monitoring, and planning for each iteration. Because things can change so rapidly, automated guidance in performing process must be updated for each iteration because the environment and the available reusable process could change. In addition, the original guidance and suggestions for the project also need to be updated to account for these changes as well.   In essence the automation of process execution is supported by the agile methodology because during every iteration all processes must be tested, evaluated to ensure process integrity and compliance with the customer’s requirements. I do not think the agile approach diminishes modeling, in fact I think it increases the modeling because before the start of every development cycle, modeling must be checked for accuracy based on the changed requirements. So in essence the reduced time spent initially designing the models is in fact gained as the project completes every iteration of the project.

    Read the article

< Previous Page | 101 102 103 104 105 106 107 108 109 110 111 112  | Next Page >