Search Results

Search found 87932 results on 3518 pages for 'code vader'.

Page 114/3518 | < Previous Page | 110 111 112 113 114 115 116 117 118 119 120 121  | Next Page >

  • Type-safe generic data structures in plain-old C?

    - by Bradford Larsen
    I have done far more C++ programming than "plain old C" programming. One thing I sorely miss when programming in plain C is type-safe generic data structures, which are provided in C++ via templates. For sake of concreteness, consider a generic singly linked list. In C++, it is a simple matter to define your own template class, and then instantiate it for the types you need. In C, I can think of a few ways of implementing a generic singly linked list: Write the linked list type(s) and supporting procedures once, using void pointers to go around the type system. Write preprocessor macros taking the necessary type names, etc, to generate a type-specific version of the data structure and supporting procedures. Use a more sophisticated, stand-alone tool to generate the code for the types you need. I don't like option 1, as it is subverts the type system, and would likely have worse performance than a specialized type-specific implementation. Using a uniform representation of the data structure for all types, and casting to/from void pointers, so far as I can see, necessitates an indirection that would be avoided by an implementation specialized for the element type. Option 2 doesn't require any extra tools, but it feels somewhat clunky, and could give bad compiler errors when used improperly. Option 3 could give better compiler error messages than option 2, as the specialized data structure code would reside in expanded form that could be opened in an editor and inspected by the programmer (as opposed to code generated by preprocessor macros). However, this option is the most heavyweight, a sort of "poor-man's templates". I have used this approach before, using a simple sed script to specialize a "templated" version of some C code. I would like to program my future "low-level" projects in C rather than C++, but have been frightened by the thought of rewriting common data structures for each specific type. What experience do people have with this issue? Are there good libraries of generic data structures and algorithms in C that do not go with Option 1 (i.e. casting to and from void pointers, which sacrifices type safety and adds a level of indirection)?

    Read the article

  • refactoring my code. My headers (Header Guard Issues)

    - by numerical25
    I had a post similar to this awhile ago based on a error I was getting. I was able to fix it but since then I been having trouble doing things because headers keep blocking other headers from using code. Honestly, these headers are confusing me and if anyone has any resources that will address these types of issues, that will be helpful. What I essentially want to do is be able to have rModel.h be included inside RenderEngine.h. every time I add rModel.h to RenderEngine.h, rModel.h is no longer able to use RenderEngine.h. (rModel.h has a #include of RenderEngine.h as well). So in a nutshell, RenderEngine and rModel need to use each others functionalities. On top of all this confusion, the Main.cpp needs to use RenderEngine. stdafx.h #include "targetver.h" #define WIN32_LEAN_AND_MEAN // Exclude rarely-used stuff from Windows headers // Windows Header Files: #include <windows.h> // C RunTime Header Files #include <stdlib.h> #include <malloc.h> #include <memory.h> #include <tchar.h> #include "resource.h" main.cpp #include "stdafx.h" #include "RenderEngine.h" #include "rModel.h" // Global Variables: RenderEngine go; rModel *g_pModel; ...code........... rModel.h #ifndef _MODEL_H #define _MODEL_H #include "stdafx.h" #include <vector> #include <string> #include "rTri.h" #include "RenderEngine.h" ........Code RenderEngine.h #pragma once #include "stdafx.h" #include "d3d10.h" #include "d3dx10.h" #include "dinput.h" #include "rModel.h" .......Code......

    Read the article

  • Passing C++ object to C++ code through Python?

    - by cornail
    Hi all, I have written some physics simulation code in C++ and parsing the input text files is a bottleneck of it. As one of the input parameters, the user has to specify a math function which will be evaluated many times at run-time. The C++ code has some pre-defined function classes for this (they are actually quite complex on the math side) and some limited parsing capability but I am not satisfied with this construction at all. What I need is that both the algorithm and the function evaluation remain speedy, so it is advantageous to keep them both as compiled code (and preferrably, the math functions as C++ function objects). However I thought of glueing the whole simulation together with Python: the user could specify the input parameters in a Python script, while also implementing storage, visualization of the results (matplotlib) and GUI, too, in Python. I know that most of the time, exposing C++ classes can be done, e.g. with SWIG but I still have a question concerning the parsing of the user defined math function in Python: Is it possible to somehow to construct a C++ function object in Python and pass it to the C++ algorithm? E.g. when I call f = WrappedCPPGaussianFunctionClass(sigma=0.5) WrappedCPPAlgorithm(f) in Python, it would return a pointer to a C++ object which would then be passed to a C++ routine requiring such a pointer, or something similar... (don't ask me about memory management in this case, though :S) The point is that no callback should be made to Python code in the algorithm. Later I would like to extend this example to also do some simple expression parsing on the Python side, such as sum or product of functions, and return some compound, parse-tree like C++ object but let's stay at the basics for now. Sorry for the long post and thx for the suggestions in advance.

    Read the article

  • How best to organize projects folders for unit tests in .NET?

    - by Dan Bailiff
    So I'm trying to introduce unit testing to my group. I've successfully upgraded a VS'05 web site project to a VS'08 web application, and now have a solution with the web app project and a unit test project. The issue now is how to fit this back into the source repository such that we don't break the build system and the unit test projects are persisted as well. Right now we have something like this: c:\root c:\root\projectA c:\root\projectB c:\root\projectC where projectA contains the sln file and all other related files/folders for the project. Now I have this new solution that looks like this: c:\root\projectA (parent folder) c:\root\projectA\projectA (the production code project) c:\root\projectA\projectA_Test (the unit test project) c:\root\projectA\TestResults c:\root\projecta\projectA.sln How do I integrate this new structure back into the code repository? I'd really prefer to keep the production code folder where it was in the source repository for the sake of the build, but is this necessary? If I keep the production code project in its usual place then where do I keep my unit test projects and how do I connect them with a sln file? Is it better to use this new structure and adjust the build process? I'd love to hear how other people are dealing with this issue of upgrading legacy projects to unit testing.

    Read the article

  • Optimize Duplicate Detection

    - by Dave Jarvis
    Background This is an optimization problem. Oracle Forms XML files have elements such as: <Trigger TriggerName="name" TriggerText="SELECT * FROM DUAL" ... /> Where the TriggerText is arbitrary SQL code. Each SQL statement has been extracted into uniquely named files such as: sql/module=DIAL_ACCESS+trigger=KEY-LISTVAL+filename=d_access.fmb.sql sql/module=REP_PAT_SEEN+trigger=KEY-LISTVAL+filename=rep_pat_seen.fmb.sql I wrote a script to generate a list of exact duplicates using a brute force approach. Problem There are 37,497 files to compare against each other; it takes 8 minutes to compare one file against all the others. Logically, if A = B and A = C, then there is no need to check if B = C. So the problem is: how do you eliminate the redundant comparisons? The script will complete in approximately 208 days. Script Source Code The comparison script is as follows: #!/bin/bash echo Loading directory ... for i in $(find sql/ -type f -name \*.sql); do echo Comparing $i ... for j in $(find sql/ -type f -name \*.sql); do if [ "$i" = "$j" ]; then continue; fi # Case insensitive compare, ignore spaces diff -IEbwBaq $i $j > /dev/null # 0 = no difference (i.e., duplicate code) if [ $? = 0 ]; then echo $i :: $j >> clones.txt fi done done Question How would you optimize the script so that checking for cloned code is a few orders of magnitude faster? System Constraints Using a quad-core CPU with an SSD; trying to avoid using cloud services if possible. The system is a Windows-based machine with Cygwin installed -- algorithms or solutions in other languages are welcome. Thank you!

    Read the article

  • How to construct objects based on XML code?

    - by the_drow
    I have XML files that are representation of a portion of HTML code. Those XML files also have widget declarations. Example XML file: <message id="msg"> <p> <Widget name="foo" type="SomeComplexWidget" attribute="value"> inner text here, sets another attribute or inserts another widget to the tree if needed... </Widget> </p> </message> I have a main Widget class that all of my widgets inherit from. The question is how would I create it? Here are my options: Create a compile time tool that will parse the XML file and create the necessary code to bind the widgets to the needed objects. Advantages: No extra run-time overhead induced to the system. It's easy to bind setters. Disadvantages: Adds another step to the build chain. Hard to maintain as every widget in the system should be added to the parser. Use of macros to bind the widgets. Complex code Find a method to register all widgets into a factory automatically. Advantages: All of the binding is done completely automatically. Easier to maintain then option 1 as every new widget will only need to call a WidgetFactory method that registers it. Disadvantages: No idea how to bind setters without introducing a maintainability nightmare. Adds memory and run-time overhead. Complex code What do you think is better? Can you guys suggest a better solution?

    Read the article

  • Java - A better to run code for a period of time

    - by mhollander38
    I need to run some code for a predefined length of time, when the time is up it needs to stop. Currently I am using a TimerTask to allow the code to execute for a set amount of time but this is causing endless threads to be created by the code and is just simply not efficient. Is there a better alternative? Current code; // Calculate the new lines to draw Timer timer3 = new Timer(); timer3.schedule(new TimerTask(){ public void run(){ ArrayList<String> Coords = new ArrayList<String>(); int x = Float.valueOf(lastFour[0]).intValue(); int y = Float.valueOf(lastFour[1]).intValue(); int x1 = Float.valueOf(lastFour[2]).intValue(); int y1 = Float.valueOf(lastFour[3]).intValue(); //Could be the wrong way round (x1,y1,x,y)? Coords = CoordFiller.coordFillCalc(x, y, x1, y1); String newCoOrds = ""; for (int j = 0; j < Coords.size(); j++) { newCoOrds += Coords.get(j) + " "; } newCoOrds.trim(); ClientStorage.storeAmmendedMotion(newCoOrds); } } ,time);

    Read the article

  • Strange code behaviour?

    - by goldenmean
    Hi, I have a C code in which i have a structure declaration which has an array of int[576] declared in it. For some reason, i had to remove this array from the structure, So i replaced this array with a pointer as int *ptr; declared some global array of same type, somewhere else in the code, and initialized this pointer by assigning the global array to this pointer. So i did not have to change the way i was accessing this array, from other parts of my code. But it works fine/gives desired output when i have the array declared in the structure, but it gives junk output when i declare it as a pointer in the structure and assign a global array to this pointer, as a part of the pointer initialization. All this code is being run on MS-VC 6.0/Windows setup/Intel-x86. I tried below things: 1)Suspected structure padding/alignment but could not get any leads? If at all structure alignment could be a culprit how can i proceed to narrow it down and confirm it? 2) I have made sure that in both cases the array is initialized to some default values, say 0 before its first use, and its not being used before initialization. 3)I tried using global array as well as malloc based memory for this newly declared array. Same result, junk output. Am i missing something? How can i zero down the problem. Any pointers would be helpful. Thanks, -AD.

    Read the article

  • Convert one delphi code line to c++

    - by user1332636
    How can I write that line in c++? This is the code in delphi type TSettings = record sFileName: String[50]; siInstallFolder: Byte; bRunFile: Boolean; ... end; .. var i: dword; sZdData: PChar; Settings :Tsettings; begin .... ZeroMemory(@Settings, sizeof(Tsettings)); settings := Tsettings(Pointer(@sZdData[i])^); // this code to c++ c++ code (hope the rest is OK) struct TSettings{ char sFileName[50]; byte siInstallFolder; bool bRunFile; ... } Settings; ... DWORD i; LPBYTE sZdData; ZeroMemory(&Settings, sizeof(TSettings)); Settings = ????? // im failing here i dunno what to do // i need same as in delphi code above

    Read the article

  • Best strategies for reading J code

    - by estanford
    I've been using J for a few months now, and I find that reading unfamiliar code (e.g. that I didn't write myself) is one of the most challenging aspects of the language, particularly when it's in tacit. After a while, I came up with this strategy: 1) Copy the code segment into a word document 2) Take each operator from (1) and place it on a separate line, so that it reads vertically 3) Replace each operator with its verbal description in the Vocabulary page 4) Do a rough translation from J syntax into English grammar 5) Use the translation to identify conceptually related components and separate them with line breaks 6) Write a description of what each component from (5) is supposed to do, in plain English prose 7) Write a description of what the whole program is supposed to do, based on (6) 8) Write an explanation of why the code from (1) can be said to represent the design concept from (7). Although I learn a lot from this process, I find it to be rather arduous and time-consuming -- especially if someone designed their program using a concept I never encountered before. So I wonder: do other people in the J community have favorite ways to figure out obscure code? If so, what are the advantages and disadvantages of these methods?

    Read the article

  • Code Keeps Timing Out

    - by DForck42
    So, we've got this set of code that, for some reason, keeps timing out. It's not the stored procedure that it's running, because that runs fine. Also, if we remove the parameter from the c# code, the code runs. The parameter keeps breaking (causing it to time out) and we can't figure out why. c#: public static PTWViewList GetList(int studynumber) { PTWViewList tempList = new PTWViewList(); using (SqlConnection myConnection = new SqlConnection(AppConfiguration.cnARDB)) { string spName = "ardb.PTWViewSelect"; SqlCommand myCommand = new SqlCommand(spName, myConnection); myCommand.CommandType = CommandType.StoredProcedure; myCommand.Parameters.AddWithValue("@study", studynumber); myConnection.Open(); using (NullableDataReader myReader = new NullableDataReader(myCommand.ExecuteReader())) /*this is where the code times out*/ { tempList = new PTWViewList(); while (myReader.Read()) { tempList.Add(FillDataRecord(myReader)); } myReader.Close(); } } tempList.ListCount = tempList.Count; return tempList; } stored procedure: CREATE PROCEDURE [ardb].[PTWViewSelect] @studynumber int = NULL, @quoteid uniqueidentifier = NULL, @lineitemid uniqueidentifier = NULL AS BEGIN SET NOCOUNT ON; SELECT [Study] ,[LineItemID] ,[QuoteID] ,[Total] ,[COOP] ,[VendorCost] ,[CustCost] ,[LineItemNumber] ,[StudyTypeCode] ,[GroupLeader] ,[PTWDate] ,[PONumber] ,[POStatus] ,[StudyDirector] ,[SL_DESC_L] ,[SL_Code] ,ProjectDescription ,CreatedBy ,chARProcess ,CODate FROM [ARDB].[dbo].[PTWView] WHERE (@studynumber is null or StudyNumber=@studynumber) AND (@quoteid is null or QuoteID=@quoteid) AND (@lineitemid is null or LineItemID = @lineitemid) END

    Read the article

  • convert a repeating code to method

    - by Mr_Green
    In my project, I am adding ComboBox, Text, Link label to my DataGridView dgvMain.I have created different methods for different cell templates as shown below: (The code below is working) gridLnklbl(string headerName) DataGridViewLinkColumn col = new DataGridViewLinkColumn(); col.HeaderText = headerName; // col.Name = "col" + headerName; // same code repeating to all the methods dgvMain.Columns.Add(col); // gridCmb(string headerName) DataGridViewComboBoxColumn col = new DataGridViewComboBoxColumn(); col.HeaderText = headerName; col.Name = "col" + headerName; dgvMain.Columns.Add(col); gridText(string headerName) DataGridViewTextBoxColumn col = new DataGridViewTextBoxColumn(); col.HeaderText = headerName; col.Name = "col" + headerName; dgvMain.Columns.Add(col); As you can see, except the declaration of objects, the code for every method is repeating. Just curious to know, can the repeating code be converted to single method? I dont know how to do that.. Its not about 3 codes of line, I have written many more lines which can be make common to those methods.

    Read the article

  • Hyper-V Virtual Ethernet Adapter not working probperly - Code 31 on Host

    - by Chris S
    I have a Windows 8.1 machine with Hyper-V installed. From a "clean" Hyper-V configuration I open Virtual Switch Manager, create an External switch with "Allow management operating system to share this network adapter", click OK. Everything seems to work properly but the host loses network connectivity. Opening Device Manager, the "Hyper-V Virtual Ethernet Adapter" is shown under the Network Adapter section with a yellow triangle, and the following message: This device is not working properly because Windows cannot load the drivers required for this device. (Code 31) An object ID was not found in the file. I tried "Uninstalling" the device, seems to work, but the device doesn't actually remove. I tried removing and re-adding the Hyper-V feature completely, no difference. Tried scf /scannow, no problems. System and Application logs show no errors. The Hyper-V-VMMS Networking log shows the following: Log Name: Microsoft-Windows-Hyper-V-VMMS-Networking Source: Microsoft-Windows-Hyper-V-VMMS Date: 10/24/2013 10:53:07 AM Event ID: 26088 Description: Failed to apply static IP settings to internal Ethernet adapter {A813DE9A-BE70-4FAE-AD31-BE4D54505A4B} ('885435B8-BE65-4EE9-826D-AB56035237ED'): Unspecified error (0x80004005). If I try to remove the Virtual Switch in Hyper-V Virtual Switch Manager I get this in that same log: Log Name: Microsoft-Windows-Hyper-V-VMMS-Networking Source: Microsoft-Windows-Hyper-V-VMMS Date: 10/24/2013 11:19:47 AM Event ID: 26142 Description: Failed while removing virtual Ethernet switch. Trying to remove the Virtual Switch leads to an error: Error applying Virtual Switch Properties changes Failed while removing virtual Ethernet switch. VM Networking does work.

    Read the article

  • Remote App Authentication Error (Code:0x507)

    - by CMK
    Hi I'm trying to get RDP services running with Windows 2008 R2. I'm at a WINXP SP3 client that was modified to run RDP with NLA. When I start the client connect to the local DC and get an authentification error (Code 0x507). I've already done the following: • Server Setup to run as a standalone local "DC" to provide Terminal services to a single application. Remote Desktop Session Host CAL License is running & operational, RD Gateway Manager w/ Local Server RAP & CAP running NLA & operational etc..... Server has NLA & temporary use of port 3389 (which is directly connected to and accessible from the internet (I am planning to change the port to 443, but want to get the current system running first). • XP Client(s): RDP-Version on win xp clients is 6.1 If had SP2, then added SP3 and edited the registry settings to allow NLA, by: Click Start, click Run, type regedit, and then press ENTER. In the navigation pane, locate and then click the following registry subkey: HKEY_LOCAL_MACHINE \SYSTEM\CurrentControlSet\Control\Lsa In the details pane, right-click Security Packages, and then click Modify. In the Value data box, type tspkg. Leave any data that is specific to other SSPs, and then click OK. In the navigation pane, locate and then click the following registry subkey: HKEY_LOCAL_MACHINE \SYSTEM\CurrentControlSet\Control\SecurityProviders In the details pane, right-click SecurityProviders, and then click Modify. In the Value data box, type credssp.dll. Leave any data that is specific to other SSPs, and then click OK. Exit Registry Editor. Restart the computer.

    Read the article

  • Enabling syntax highlighting for LESS in Programmer's Notepad?

    - by Cody Gray
    When I don't feel like firing up the Visual Studio behemoth, or when I don't have it installed, I always turn to Programmer's Notepad. It's an amazingly light and fast little text editor, with the special advantage that it is completely platform-native and conforms to standard UI conventions. Therefore, please do not suggest that I consider using other text editors. I've already considered and rejected them because they do not use native UI controls. I like Programmer's Notepad, thank you very much. Unfortunately, I've recently begun to learn, use, and love LESS for all of my CSS coding needs, and it appears that Programmer's Notepad is not bundled with a syntax highlighting scheme for LESS. Does anyone know if there is—by chance and good fortune—one already available somewhere on the web that some kind soul has tediously prepared? If not, how can I go about writing one of my own? Is there a way to build on the existing CSS scheme? It's also possible that any code coloring scheme designed for Scintilla-based editors will work, as Programmer's Notepad is based on the Scintilla control. If you know of a LESS highlighting scheme for Scintilla-based editors, and how to use that with Programmer's Notepad, please suggest that as well.

    Read the article

  • BOINC error code -1200 when opening...

    - by Erik Vold
    I installed boinc 6.10.21 on my macosx 10.5 in order to upgrade from a 6.6 version that I was running today, and I am the admin user, and I was logged in as the admin user. As I was installing 6.10.21 I was asked if non admin users should be allowed to use boinc, and I said 'yes' to this. Then when I tried to open boinc I got a message like the following: "You currently are not authorized to manage the client. Either re-install and allow non-admin users or contact your administrator to add you to the 'boinc_master' user group." So I tried to reinstall first, and I was not asked if non admin users should be allowed to use boinc.. so I retried a few times and got no different result.. So I downloaded 6.10.43 and installed that, and again I was not asked if non admin users should be allowed to use boinc.. and when I tried to run boinc I got the same message like: "You currently are not authorized to manage the client. Either re-install and allow non-admin users or contact your administrator to add you to the 'boinc_master' user group." So I did a google search trying to figure out how to add my admin user to the bonic_master user group and found this which suggested I run the following in terminal: "sudo dscl . -append /Groups/boinc_master GroupMembership <your user's short name> CR" So I did this and now I get the following error: BOINC ownership or permissions are not set properly; please reinstall BOINC (Error code -1200) So I reinstall and I am ever asked the question about allowing non admin users again, and I still get this error message every after every reinstall attempt.. What should I do?..

    Read the article

  • Windows Remote Desktop (RDP/MSTSC) fails with Error Code: 5

    - by BryCoBat
    I have 2 Windows XP boxen: A (running XP SP3) and B (running XP SP2). I'm using Remote Desktop to connect from A to B. When I connect, I get the login screen (which is slow to respond to keyboard/mouse input), and after logging in, I get the following: Fatal Error (Error Code: 5) Your Remote Desktop session is about to end. This computer might be low on virtual memory. Close your other programs, and then try connecting to the remote computer again. If the problem continues, contact your network administrator or technical support. I've seen one way to (sometimes) get in by opening a second RDP session to the same box [1], and if I wait long enough sometimes it will go ahead and log in anyway. Is there something broken/missing on the PC I'm trying to remote in to? Edited in reply to djangofan: There's nobody listed under "Lock pages in memory". When the double login trick works, a glance at Task Manager shows plenty of free memory, 800MB available out of 1.5 GB. (Performance tab, Physical memory) For what it's worth, this happens consistently after a reboot. What sort of exact info would be useful? There's very little remaining installed on that machine that's not Windows + Office... [1] found at http://www.fdcservers.net/vbulletin/archive/index.php/t-1580.html

    Read the article

  • IIS 7.5 / Windows 7: Error 500.19, error code 0x800700b7

    - by nikhiljoshi
    I have been trying to resolve this issue. I am using Windows 7 and VS2008 +iis7.5. My project is stuck because of this error. The error says: Error Summary HTTP Error 500.19 - Internal Server Error The requested page cannot be accessed because the related configuration data for the page is invalid. `Detailed Error Information Module IIS Web Core Notification BeginRequest Handler Not yet determined Error Code 0x800700b7 Config Error There is a duplicate 'system.web.extensions/scripting/scriptResourceHandler' section defined Config File \\?\C:\inetpub\wwwroot\test23\web.config Requested URL http://localhost:80/test23 Physical Path C:\inetpub\wwwroot\test23 Logon Method Not yet determined Logon User Not yet determined Config Source 15: <sectionGroup name="scripting" type="System.Web.Configuration.ScriptingSectionGroup, System.Web.Extensions, Version=3.5.0.0, Culture=neutral, PublicKeyToken=31BF3856AD364E35"> 16: <section name="scriptResourceHandler" type="System.Web.Configuration.ScriptingScriptResourceHandlerSection, System.Web.Extensions, Version=3.5.0.0, Culture=neutral, PublicKeyToken=31BF3856AD364E35" requirePermission="false" allowDefinition="MachineToApplication"/> 17: <sectionGroup name="webServices" type="System.Web.Configuration.ScriptingWebServicesSectionGroup, System.Web.Extensions, Version=3.5.0.0, Culture=neutral, PublicKeyToken=31BF3856AD364E35"> ` I followed the instructions in this Microsoft solution document, but it didn't help. http://support.microsoft.com/kb/942055

    Read the article

  • Computer restarts without warning; code bcc116

    - by Robert C.
    Processor: Intel i5 4430 4-Core 4x3Ghz Motherboard: msi h87-g41 Graphics Card: Nvidia GTX760 Power supply: eps-750 cm RAM: 8GB I bought a new assembled gaming PC which worked fine for a few days. Then it started rebooting without warning. After it restarts windows 7 gives me an bbc 116 error code. Apparently it's something to do with my video card, either it overheating or wrong drivers. I've installed the latest driver from Nvidia for my graphics card. Since it's brand new it can't be dust, I'm running it with its lid open to see if the problem persists. I'm also running prime95 now to see if it tells me anything else. Using core temp it tells me that my CPU reaches up to 95° celsius with the blend stress test from prime95. Aaaand it just peaked to 100°. Of course it doesn't reach these temperatures at all while idle/gaming. I'm gonna let prime95 run for a night and to see what happens. Until then does anyone know what I should do next?

    Read the article

  • Error code 1005 (errno: 121) upon create table while restoring MySQL database from a dump

    - by Jonathan
    I have a linux prod machine and a Win7 64bit dev machine. My workflow includes dumping the production MySQL database on the linux machine and restoring it in my local MySQL database on the windows machine (using SQLyog). This worked fine for a long time. Following some trouble, I formatted and reinstalled my windows dev machine. Since then I'm unable to restore the db on it. I keep receiving the following error: Query: CREATE TABLE `auth_group` ( `id` int(11) NOT NULL auto_increment, `name` varchar(80) collate utf8_unicode_ci NOT NULL, PRIMARY KEY (`id`), UNIQUE KEY `name` (`name`) ) ENGINE=InnoDB AUTO_INCREMENT=2 DEFAULT CHARSET=utf8 COLLATE=utf8_unicode_ci Error occured at:2010-06-26 17:16:14 Line no.:30 Error Code: 1005 - Can't create table 'ap_site.auth_group' (errno: 121) Notice that this is the first create table statement in the sql dump file. This error occurs both on MySQL Community Server 5.1.41 and 5.1.48 and with SQLyog Community 8.0.4 and 8.5.1. I really don't know what's different in my configuration from before the reinstall and now and why does it have this effect. Restoring from sql dump is something I need to keep on doing, so I need a permanent fix and not a tailored workaround.

    Read the article

  • Connecting to my home router web interface from work

    - by Joe
    Hi, I'm trying to connect to my home router web interface from work. I use dyndns, because I don't have a static IP at home, and it works perfectly from any other place except my workplace (update: I made a mistake, see edit below). When trying to access the web interface from work I get a "500 Server Error" with the code: SERVER_RESPONSE_RESET. I'm not trying to use any protocols such as remote desktop, I'm only trying to access the web interface. I can access any other web page from my workplace with no problems, and I think my router web interface is like any other web page, isn't it? I thought maybe my work place proxy blocks addresses of services like dyndns, so I also applied another trick. Since I have a web page on my own domain (say www.mydomain.com) which I can access from work, I tried adding a CNAME to my domain which is linked to the dyndns address (router.mydomain.com). This way if anyone enters the address router.mydomain.com from anywhere, they reach my home router web interface, and there's no way of knowing it's a dyndns address (or is there?). However, it still doesn't work from my workplace (I get the same error message). Any ides? Edit: I'm sorry to say I made a mistake earlier. I used to be able to access my home router web interface from my old workplace, and I thought it was still possible since I don't recall making any configuration changes. However, after reading the replies, I went over to my old workplace and checked, and it doesn't work from there either. I'm very sorry for giving out wrong and misleading information about my problem. So to summarize: my problem is that I can't access my home router web interface from anywhere.

    Read the article

  • Android webbrowser returns code 500 for webpage on Nginx webserver

    - by Paxxil
    Hey! I've come to a very weird behavior of a web browser on android mobile phone (I've tried HTC Wildfire and HTC Desire phones). I have a web server with Nginx v0.8.54. When i try to open a web page on the phone it shows me error: The requested item could not be loaded! (Status code: 500) BUT it only happens when I am requesting page through Mobile network. On Wifi it works just fine .... but there is more .... if I stop Nginx and start Apache web server it works just fine on both Mobile network and wifi. I've also tried other mobile network and it is the same behavior. Some server stats: Firewall is OFF Selinux is OFF the web page (using Nginx web server) opens normally on any other browser (IE, FF, Opera, Chrome, Safari) on the laptop or PC Nothing in nginx error.log This is the only entry in access.log when the page is requested: xxx.xxx.xxx.xxx - - [17/Mar/2011:11:19:49 -0500] 200 "GET / HTTP/1.1" 27405 "-" "Mozilla/5.0 (Linux; U; Android 2.2; en-gb; Desire_A8181 Build/FRF91) AppleWebKit/533.1 (KHTML, like Gecko) Version/4.0 Mobile Safari/533.1" "-" index.html has only "Hello World" string in it. There is no fishy javascript or anything else. .... but there is even more.... if i open the same page on another server, with the same Nginx build, with the same server and web server configuration.... it opens just fine. if anyone has any idea on what may be going on, i would really appreciate it if you let me know. Thanks! EDIT: i forgot to mention that page opens OK on Iphone and Nokia

    Read the article

  • Hacked website, code is encrypted in hex, unable to identify

    - by dhakad
    my web site hacked and i am getting code in index page, but i am unable to find that where is the code in my web site... %3c%68%74%6d%6c%3e%3c%68%65%61%64%3e%0d%0a%3c%6d%65%74%61%20%63%6f%6e%74%65%6e%74%3d%22%74%65%78%74%2f%68%74%6d%6c%3b%20%63%68%61%72%73%65%74%3d%75%74%66%2d%38%22%3e%0d%0a%3c%74%69%74%6c%65%3e%2e%2f%20%72%45%64%20%58%20%7c%20%33%78%70%31%72%33%20%43%79%62%65%72%20%41%72%6d%79%3c%2f%74%69%74%6c%65%3e%0d%0a%3c%6d%65%74%61%20%6e%61%6d%65%3d%22%61%75%74%68%6f%72%22%20%63%6f%6e%74%65%6e%74%3d%22%72%45%64%20%58%22%20%2f%3e%0d%0a%3c%6d%65%74%61%20%6e%61%6d%65%3d%22%6b%65%79%77%6f%72%64%73%22%20%63%6f%6e%74%65%6e%74%3d%22%72%45%64%20%58%2c%33%78%70%31%72%33%20%43%79%62%65%72%20%41%72%6d%79%2c%5a%6f%6e%65%2d%48%2c%42%61%6e%67%6c%61%64%65%73%68%69%20%48%61%63%6b%65%72%22%20%2f%3e%0d%0a%3c%6d%65%74%61%20%6e%61%6d%65%3d%22%64%65%73%63%72%69%70%74%69%6f%6e%22%20%63%6f%6e%74%65%6e%74%3d%22%5b%20%72%45%64%20%58%20%2e%2e%20%54%68%65%20%52%65%61%6c%20%4f%75%74%72%61%67%65%6f%75%73%20%5d%22%20%2f%3e%0d%0a%3c%6c%69%6e%6b%20%72%65%6c%3d%22%53%48%4f%52%54%43%55%54%20%49%43%4f%4e%22%20%68%72%65%66%3d%22%68%74%74%70%3a%2f%2f%75%73%2e%79%69%6d%67%2e%63%6f%6d%2f%69%2f%6d%65%73%67%2f%65%6d%6f%74%69%63%6f%6e%73%37%2f%36%31%2e%67%69%66%22%3e%0d%0a%3c%73%74%79%6c%65%20%74%79%70%65%3d%22%74%65%78%74%2f%63%73%73%22%3e%0d%0a%62%6f%64%79%20%7b%62%61%63%6b%67%72%6f%75%6e%64%2d%69%6d%61%67%65%3a%20%75%72%6c%28%68%74%74%70%3a%2f%2f%6d%65%64%69%61%2e%73%6f%6d%65%77%68%65%72%65%69%6e%62%6c%6f%67%2e%6e%65%74%2f%69%6d%61%67%65%73%2f%6f%6e%64%68%6f%6b%61%72%65%72%5f%72%61%6a%70%75%74%72%61%5f%31%33%33%38%32%35%30%34%33%31%5f%31%2d%62%67%2e%67%69%66%29%3b%0d%0a%62%61%63%6b%67%72%6f%75%6e%64%2d%63%6f%6c%6f%72%3a%20%62%6c%61%63%6b%3b%63%6f%6c%6f%72%3a%20%23%46%46%41%35%30%30%3b%66%6f%6e%74%2d%77%65%69%67%68%74%3a%20%62%6f%6c%64%3b%74%65%78%74%2d%61%6c%69%67%6e%3a%20%63%65%6e%74%65%72%3b%7d%0d%0a%69%6d%67%7b%6f%70%61%63%69%74%79%3a%30%2e%37%35%3b%20%66%69%6c%74%65%72%3a%61%6c%70%68%61%28%6f%70%61%63%69%74%79%3d%37%35%29%3b%7d%0d%0a%2e%72%65%64%78%20%7b%74%65%78%74%2d%73%68%61%64%6f%77%3a%20%30%20%30%20%36%70%78%20%72%65%64%2c%20%30%20%30%20%35%70%78%20%72%65%64%2c%20%30%20%30%20%35%70%78%20%72%65%64%3b%63%6f%6c%6f%72%3a%20%23%46%46%46%7d%0d%0a%3c%2f%73%74%79%6c%65%3e%0d%0a%3c%2f%68%65%61%64%3e%0d%0a%3c%62%6f%64%79%20%6f%6e%63%6f%6e%74%65%78%74%6d%65%6e%75%3d%22%72%65%74%75%72%6e%20%66%61%6c%73%65%22%20%6f%6e%6b%65%79%64%6f%77%6e%3d%22%72%65%74%75%72%6e%20%66%61%6c%73%65%22%20%6f%6e%6d%6f%75%73%65%64%6f%77%6e%3d%22%72%65%74%75%72%6e%20%66%61%6c%73%65%22%3e%0d%0a%3c%64%69%76%20%73%74%79%6c%65%3d%22%66%6f%6e%74%2d%66%61%6d%69%6c%79%3a%20%50%61%6c%61%74%69%6e%6f%20%4c%69%6e%6f%74%79%70%65%3b%66%6f%6e%74%2d%73%69%7a%65%3a%20%34%36%70%78%3b%22%20%63%6c%61%73%73%3d%22%72%65%64%78%22%3e%2e%3a%3a%20%72%45%64%20%58%20%57%61%73%20%48%65%72%65%20%3a%3a%2e%3c%2f%64%69%76%3e%3c%62%72%2f%3e%0d%0a%3c%69%6d%67%20%73%72%63%3d%22%68%74%74%70%3a%2f%2f%6d%65%64%69%61%2e%73%6f%6d%65%77%68%65%72%65%69%6e%62%6c%6f%67%2e%6e%65%74%2f%69%6d%61%67%65%73%2f%6f%6e%64%68%6f%6b%61%72%65%72%5f%72%61%6a%70%75%74%72%61%5f%31%33%35%33%35%35%32%36%35%31%5f%31%2d%72%65%64%2d%78%2e%6a%70%67%22%3e%3c%62%72%2f%3e%0d%0a%3c%64%69%76%20%73%74%79%6c%65%3d%22%66%6f%6e%74%2d%66%61%6d%69%6c%79%3a%20%42%6f%6f%6b%6d%61%6e%20%4f%6c%64%20%53%74%79%6c%65%3b%63%6f%6c%6f%72%3a%20%23%30%30%30%3b%66%6f%6e%74%2d%73%69%7a%65%3a%20%32%30%70%78%3b%6d%61%72%67%69%6e%3a%30%3b%74%65%78%74%2d%73%68%61%64%6f%77%3a%20%30%20%31%70%78%20%33%70%78%20%23%30%30%46%46%30%30%2c%20%2d%31%70%78%20%30%20%33%70%78%20%23%30%30%46%46%30%30%2c%20%30%20%2d%31%70%78%20%33%70%78%20%23%30%30%46%46%30%30%2c%20%31%70%78%20%30%20%33%70%78%20%23%30%30%46%46%30%30%3b%22%3e%50%72%6f%75%64%20%54%6f%20%62%65%20%61%20%42%61%6e%67%6c%61%64%65%73%68%69%20%48%61%63%6b%65%72%3c%2f%64%69%76%3e%3c%62%72%2f%3e%0d%0a%3c%64%69%76%20%73%74%79%6c%65%3d%22%66%6f%6e%74%2d%66%61%6d%69%6c%79%3a%20%42%65%72%6c%69%6e%20%53%61%6e%73%20%46%42%3b%63%6f%6c%6f%72%3a%20%23%31%35%31%42%35%34%3b%66%6f%6e%74%2d%73%69%7a%65%3a%20%32%30%70%78%3b%74%65%78%74%2d%73%68%61%64%6f%77%3a%20%30%20%30%20%33%70%78%20%23%30%30%46%46%30%30%2c%20%30%20%30%20%33%70%78%20%23%30%30%46%46%30%30%2c%20%30%20%30%20%33%70%78%20%23%66%66%66%2c%20%30%20%30%20%35%70%78%20%23%46%30%30%2c%20%30%20%30%20%35%70%78%20%23%66%66%32%64%39%35%3b%22%3e%44%65%61%72%20%41%44%4d%49%4e%3c%62%72%2f%3e%21%20%53%65%63%75%72%65%20%79%6f%75%72%20%53%49%54%45%20%21%3c%2f%64%69%76%3e%3c%62%72%2f%3e%0d%0a%3c%64%69%76%20%73%74%79%6c%65%3d%22%66%6f%6e%74%2d%73%69%7a%65%3a%20%31%38%70%78%3b%66%6f%6e%74%2d%66%61%6d%69%6c%79%3a%20%43%65%6e%74%75%72%79%20%47%6f%74%68%69%63%3b%63%6f%6c%6f%72%3a%20%23%30%30%30%3b%74%65%78%74%2d%73%68%61%64%6f%77%3a%20%30%20%30%20%33%70%78%20%6c%69%6d%65%2c%20%30%20%30%20%33%70%78%20%6c%69%6d%65%2c%20%30%20%30%20%35%70%78%20%23%66%66%32%64%39%35%2c%20%30%20%30%20%35%70%78%20%23%66%66%32%64%39%35%3b%22%3e%72%65%64%2d%78%40%68%61%63%6b%65%72%6d%61%69%6c%2e%63%6f%6d%3c%2f%64%69%76%3e%0d%0a%3c%62%72%2f%3e%3c%64%69%76%20%73%74%79%6c%65%3d%22%66%6f%6e%74%2d%73%69%7a%65%3a%20%32%30%70%78%3b%22%3e%2e%2e%3a%3a%7c%20%47%72%65%65%74%7a%20%7c%3a%3a%2e%2e%3c%2f%64%69%76%3e%0d%0a%3c%64%69%76%20%73%74%79%6c%65%3d%22%66%6f%6e%74%2d%66%61%6d%69%6c%79%3a%20%42%6f%6f%6b%20%41%6e%74%69%71%75%61%3b%63%6f%6c%6f%72%3a%20%67%72%65%79%3b%66%6f%6e%74%2d%73%69%7a%65%3a%20%32%30%70%78%3b%74%65%78%74%2d%73%68%61%64%6f%77%3a%20%72%65%64%20%31%70%78%20%2d%30%70%78%20%36%70%78%22%3e%2e%3a%3a%20%78%33%6f%2d%31%33%33%37%20%7c%20%47%61%62%62%79%20%7c%20%24%70%21%72%21%74%7e%24%33%33%6b%33%72%20%7c%20%46%72%45%61%4b%79%20%3a%3a%2e%3c%62%72%2f%3e%41%6c%6c%20%4d%65%6d%62%65%72%73%20%6f%66%20%33%78%70%31%72%33%20%43%79%62%65%72%20%41%72%6d%79%3c%2f%64%69%76%3e%3c%62%72%2f%3e%0d%0a%3c%65%6d%62%65%64%20%73%72%63%3d%22%68%74%74%70%3a%2f%2f%79%6f%75%74%75%62%65%2e%67%6f%6f%67%6c%65%61%70%69%73%2e%63%6f%6d%2f%76%2f%70%74%5a%31%77%6f%33%4a%73%50%63%26%61%75%74%6f%70%6c%61%79%3d%31%26%6c%6f%6f%70%3d%31%22%20%74%79%70%65%3d%22%61%70%70%6c%69%63%61%74%69%6f%6e%2f%78%2d%73%68%6f%63%6b%77%61%76%65%2d%66%6c%61%73%68%22%20%77%6d%6f%64%65%3d%22%74%72%61%6e%73%70%61%72%65%6e%74%22%20%77%69%64%74%68%3d%22%31%22%20%68%65%69%67%68%74%3d%22%31%22%3e%3c%2f%62%6f%64%79%3e%3c%2f%68%74%6d%6c%3e'

    Read the article

  • Error code 1005 (errno: 121) upon create table while restoring MySQL database from a dump

    - by Jonathan
    I have a linux prod machine and a Win7 64bit dev machine. My workflow includes dumping the production MySQL database on the linux machine and restoring it in my local MySQL database on the windows machine (using SQLyog). This worked fine for a long time. Following some trouble, I formatted and reinstalled my windows dev machine. Since then I'm unable to restore the db on it. I keep receiving the following error: Query: CREATE TABLE `auth_group` ( `id` int(11) NOT NULL auto_increment, `name` varchar(80) collate utf8_unicode_ci NOT NULL, PRIMARY KEY (`id`), UNIQUE KEY `name` (`name`) ) ENGINE=InnoDB AUTO_INCREMENT=2 DEFAULT CHARSET=utf8 COLLATE=utf8_unicode_ci Error occured at:2010-06-26 17:16:14 Line no.:30 Error Code: 1005 - Can't create table 'ap_site.auth_group' (errno: 121) Notice that this is the first create table statement in the sql dump file. This error occurs both on MySQL Community Server 5.1.41 and 5.1.48 and with SQLyog Community 8.0.4 and 8.5.1. I really don't know what's different in my configuration from before the reinstall and now and why does it have this effect. Restoring from sql dump is something I need to keep on doing, so I need a permanent fix and not a tailored workaround.

    Read the article

  • IIS 7: One Page Works, All Others Fail With "Error code: ssl_error_rx_record_too_long"

    - by Michael
    On my local machine, I have a second site bound to Port 81. Within that site is a certain page which I can browse from other machines with no problems, but all other pages fail with "Error code: ssl_error_rx_record_too_long". Each of the failing pages (as well as the lone working page), works with localhost. So, from any machine, local or remote: http://cmwmach01.mydomain.biz:81/RD/SS/SS.aspx (works) http://cmwmach01:81/RD/SS/SS.aspx (works) http://cmwmach01.mydomain.biz:81/RD/POV/SC.aspx (fails - gets changed to https) http://cmwmach01:81/RD/POV/SC.aspx (fails - gets changed to https) Everything works with localhost (locally, of course). I've tagged this question with SSL because, at one point, it would warn about an SSL cert issue (maybe this was self-signed at one point?), but now it doesn't. While there may be an issue around that, I don't see how this could cause the issue I am seeing (but, as I mention below, am I way out of my depth here). I am way out of depth here in trying to figure out why that one page works (or the others don't), so that I can make them all work. Any ideas?

    Read the article

< Previous Page | 110 111 112 113 114 115 116 117 118 119 120 121  | Next Page >