  • Monitor a COM port already in use.

    - by rross
    Is it possible to read from a COM port already in use on Windows XP? I would like to see the communication between some software and a device plugged into a serial device. I wrote a small program using C# to monitor the COM, but once it's in use by the other device it will not let you open it again. How can one monitor a COM port already in use? I'm open to 3rd party software. Thanks

    Read the article

  • Expected output from an RM-1501 RS232 interface?

    - by Jon Cage
    I have an old RM-1501 digital tachometer which I'm using to try to identify the speed of an object. According to the manual I should be able to read the data over a serial link. Unfortunately, I don't appear to be able to get any sensible output from the device (never gives a valid speed). I think it might be a signalling problem because disconnecting the CTS line starts to get some data through.. Has anyone ever developed anything for one of these / had any success?

    Read the article

  • Communicating with a MW-3170 magnetic card reader

    - by stukelly
    One of our customers has asked if we can interface with a serial magnetic card reader/encoder from a old EPOS system. The device has no make only the MW-3170 model number. Does anybody know how I can communicate with the device? I am currently looking for a programming manual on Google, without much success.

    Read the article

  • LF/CR issue with RS232 in Linux

    - by Albinoswordfish
    I've been having this problem where anytime I send a 0xA through an RS-232 in a Linux OS the receiver interprets that as 2 bytes, 0xD and 0xA. Also whenever I receive 0xD the serial port interprets that as 0xA. I've been reading that there are known issues regarding this, has anybody been able to find a solution?

    Read the article

  • Non ASCII char in PHP?

    - by domagoj412
    Hello, I am trying to send something to serial port (r232) with PHP. I am using this class: http://www.phpclasses.org/browse/package/3679.html The problem is that I am allowed to send only 1 byte. But if I send something like "1", I am actually sending 49 (ASCII for 1). Instead of send("1"), I tried with send(1) but it is no good, because this is integer which has 2 bytes. So is there a way to send a "real" char, not ASCII equivalent?

    Read the article

  • Ruby SerialPorts

    - by Seth Archer
    I'm using the ruby serial port gem. After I open up the port I send the data I want like this. sp.write [200.chr, 30.chr, 7.chr, 5.chr, 1.chr, 2.chr, 0.chr, 245.chr].to_s It doesn't work, but if I put it in a loop of around 200 times: 200.times do sp.write [200.chr, 30.chr, 7.chr, 5.chr, 1.chr, 2.chr, 0.chr, 245.chr].to_s end It works. Any ideas on why this is happening?

    Read the article

  • Sending an integer to COM1 using SerialPort

    - by Galwegian
    I'm having difficulty sending an integer to a serial port... I'm trying stuff like this, which run fine but I'm not picking anything up at the port. Private Sub fireToPort() Dim sPort As New SerialPort("COM1", 56000, Parity.None, 8, StopBits.One) sPort.Open() sPort.Write(New Byte() {Hex(1), 255}, 0, 0) sPort.Close() End Sub Any advice?

    Read the article

  • What are the licence restrictions for the RxTx Library

    - by Azder
    I want to make an Application that uses RxTx version 2.2pre2 to work with Serial Ports. What are the Licence restrictions, since it is an "LGPL v 2.1 + Linking Over Controlled Interface" licenced library if I don't use the Sun's javax.comm.* interface, but the RxTx's own gnu.io.* when importing into Java Files?

    Read the article

  • Is 0x9B (155decimal) a special control character? Why is it missing from ascii tables?

    - by Chris
    Hi, I'm working on an embedded system, and i'm having dramas getting it to send a certain chunk of data across the serial port. I narrowed it down and found that if a 0x9B is present in the message, it corrupts the message. So i then look up 0x9b (155) on http://www.asciitable.com/, and it's missing! Isn't that a bizarre coincidence! Any ideas, is this a special character or something?

    Read the article

  • What is wrong with this attempt of sending a break-signal?

    - by Jook
    I have quite a headache about this seemingly easy task: send a break signal to my device, like the wxTerm (or any similar Terminal application) does. This signal has to be 125ms long, according to my tests and the devices specification. It should result in a specific response, but what I get is a longer response than expected, and the transmitted date is false. e.g.: what it should respond 08 00 81 00 00 01 07 00 what it does respond 08 01 0A 0C 10 40 40 07 00 7F What really boggles me is, that after I have used wxTerm to look at my available com-ports (without connecting or sending anything), my code starts to work! I can send then as many breaks as I like, I get my response right from then on. I have to reset my PC in order to try it again. What the heck is going on here?! Here is my code for a reset through a break-signal: minicom_client(boost::asio::io_service& io_service, unsigned int baud, const string& device) : active_(true), io_service_(io_service), serialPort(io_service, device) { if (!serialPort.is_open()) { cerr << "Failed to open serial port\n"; return; } boost::asio::serial_port_base::flow_control FLOW( boost::asio::serial_port_base::flow_control::hardware ); boost::asio::serial_port_base::baud_rate baud_option(baud); serialPort.set_option(FLOW); serialPort.set_option(baud_option); read_start(); std::cout << SetCommBreak(serialPort.native_handle()) << std::endl; std::cout << GetLastError() << std::endl; boost::posix_time::ptime mst1 = boost::posix_time::microsec_clock::local_time(); boost::this_thread::sleep(boost::posix_time::millisec(125)); boost::posix_time::ptime mst2 = boost::posix_time::microsec_clock::local_time(); std::cout << ClearCommBreak(serialPort.native_handle()) << std::endl; std::cout << GetLastError() << std::endl; boost::posix_time::time_duration msdiff = mst2 - mst1; std::cout << msdiff.total_milliseconds() << std::endl; } Edit: It was only necessary to look at the combo-box selection of com-ports of wxTerm - no active connection was needed to be established in order to make my code work. I am guessing, that there is some sort of initialisation missing, which is done, when wxTerm is creating the list for the serial-port combo-box.

    Read the article

  • Making a cracked or activated windows uncracked

    - by ugurcode
    I have a pc which has windows 7 license but I installed windows from an image i downloaded and it is already activated. for validating genuine microsoft, i need to entet my own product key but the necessary activation tools do not exist in my windows folder. What do? I googled stuff but because the keywords are too broad I couldn't find a useful tool DAZ doesn't work, activation button doesn't show up. When I enter my original key to Windows Anytime Upgrade, I get this error When I attempt using slmgr, I get this error I used sfc /scannow Now slmgr is existing, I entered slmgr.vbs -ipk XXXXX-XXXXX-XXXXX-XXXXX-XXXXX (replacing X es with the cd key) the operation successful. Now I have installed Microsoft Security essentials, which means the problem is solved. Main steps are here open cmd enter Enter "sfc /scannow" enter slmgr.vbs -ipk XXXXX-XXXXX-XXXXX-XXXXX-XXXXX Success

    Read the article

  • How do I use a Minitel terminal as a linux dumb terminal

    - by Pawz
    I recently purchased a US version of the Alcatel Minitel terminal. I think it's a 1B version. Pictures of it here: I tried connecting a null modem to the 25 pin port on the back and plugging it into a linux box running agetty but I couldn't get it to show any signs of being connected. I used Google Translate to translate this document into English: http://mirabellug.org/wikini/upload/Documentations_minitel.pdf As far as I can tell, you take it out of videotex mode by typing Fcnt-T A, then turn off local echo with Fcnt-T E, then set it to 4800 baud with Fcnt-P 4. I presume Fcnt refers to the "CTRL" key on my terminal. But I think I'm doing something wrong, because it doesn't look like it's recognising the keystrokes, because "Fcnt-T A" just prints the letter A to the screen, which is not what you'd expect a function key combo to do. Has anyone used these minitel terminals as a linux terminal, and if so, please can you share how to configure the minitel to run as a terminal ? Is the 25 pin plug even the correct port to use ? I read something online that indicated you're supposed to use the 5 pin DIN plug instead, is that right ? If so, what's the 25 pin plug for ? If I am supposed to use the DIN plug, does anyone know the pinouts so I can make a cable ?

    Read the article

  • Can I set up a COM Port that Connects via TCP/IP?

    - by Kristopher Johnson
    I have an RS232 device connected to a Digi PortServer on my network. I can telnet to the Digi's IP and port number to communicate with that RS232 device. I have a Windows application that knows how to talk to the device, but it wants to connect directly to an RS232 port. So, my question: Is there some way to set up a COM port so that when this application connects to it, it goes through the network to the Digi to communicate with the device? I have run across the utility TCP-Com, which seems like it might be a solution. Is this the best option?

    Read the article

  • What do the numbers on Western Digital drives mean?

    - by Evan Carroll
    There are numerous numbers on a Western Digital drive, MDL (presumably model, ex WD5000BEKT-00KA9T0) -- not sure what the 99KA9T0 is. WWN (ex 50014EE25AC8C945) DCM (ex HBNTJBBB) LBA (ex 976773168) R/N (ex 77174) Then there are three numbers on the back of the PCB on a sticker White Sticker Left: 2061-771714-002 AC White Sticker Right: XT BD34 T7KQ 8 0002270 White Sticker far-Right: 272 Then there is one number printed on the PCB, REV P1 2060-771714-002 Then there is one number (or three) on the spindle, 71206-T8Y-03 9X0X22MF 32H Does anyone know what these numbers mean?

    Read the article

  • What is the minimum delay between two consecutive RS232 frames?

    - by Lord Loh.
    I have been working on creating a UART on an FPGA. I can successfully transmit and receive single characters typed on PuTTY. However, when I set my FPGA to constantly write a large sequences of "A", sometimes I end up with a sequences of "@" or some other characters until I reset the FPGA a few times. I believe the UART on the computer looses track of the difference between the start bit and a zero. The delay between the two "A" is ~ 30us (measured with a logic analyzer) and the baud rate is 115200 8N1. Is there a minimum delay that must be maintained between two consecutive RS232 frames?

    Read the article

  • TCP > COM1 for receiving messages and displaying on POS display pole

    - by JakeTheSnake
    I currently have a Java Applet running on my web page that communicates to a display pole via COM1. However since the Java update I can no longer run self-signed Java Applets and I figure it would just be easier to send an AJAX request back to the server and have the server send a response to a TCP port on the computer...the computer would need a TCP COM virtual adapter. How do I install a virtual adapter to go from a TCP port to COM1? I've looked into com0com and that is just confusing as hell to me, and I don't see how to connect any ports to COM1. I've tried tcp2com but it doesn't seem to install the service in Windows 7 x64. I've tried com2tcp and the interface seems like it WOULD work (I haven't tested), but I don't want an app running on the desktop...it needs to be a service that runs in the background. So to summarize how it would work: Web page on comp1 sends AJAX request to server Server sends text response to comp1 on port 999 comp1 has virtual COM port listening on port 999, sends data to COM1 pole displays data

    Read the article

  • Sending a file to uCLinux

    - by Mike
    I have a board running uClinux, and I need to send a file to it, but I'm not sure how... I have a RS232 port, and Ethernet port with an IP address at my disposal, I can telnet to the board, but uCLinux doesn't have a built in FTP client. What sort of options do I have here for transferring files from my Windows 7 (or OpenSUSE) machine(s) to this board? EDIT I just found I have a TFTP server on it: # tftp BusyBox v0.60.5 (2012.07.09-14:05+0000) multi-call binary Usage: tftp [OPTION]... HOST [PORT] But I can't find any good information on how to use TFTP. And looking around google I'm seeing it's good for loading binary images, so I'm assume anything could be sent, but I'm not sure.

    Read the article

  • Impossible to Remove FTDI driver / FTDI Enumeration on Windows 7

    - by Joe
    I have already read the : Is it possible to reset FTDI virtual com ports enumeration, we easily get hundreds of COM ports in production environment topics which was pretty interesting ! But I got a problem, apparently I can't delete the ftdi driver, so I can't use the previous conclusion of the topic... I'm really stuck and bored of this problem, my com port number is 132 ! Does someone have another solution ?

    Read the article

  • How do I know if my serial adapter card is working?

    - by Ingram
    I just installed a 2 port serial adapter in my Ubuntu 10.10 system, then I tried following this tutorial that I used on my old system to connect to a cisco router (my old system had an onboard serial adapter, and the tutorial worked just fine). I can't get my system to connect to the cisco router, so I'm wondering if the card even works in Ubuntu. How can I tell if the card actually works with Ubuntu? #dmesg | grep tty [ 0.000000] console [tty0] enabled [ 0.358667] serial8250: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 0.358994] 00:0c: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 0.359128] ttyS1: detected caps 00000700 should be 00000100 [ 0.359132] 0000:03:00.0: ttyS1 at MMIO 0xfeafd000 (irq = 16) is a 16C950/954 [ 0.359191] ttyS2: detected caps 00000700 should be 00000100 [ 0.359195] 0000:03:00.0: ttyS2 at MMIO 0xfeafd200 (irq = 16) is a 16C950/954