  • C# COM Cross Thread problem

    - by user364676
    Hi, we're developing a software to control a scientific measuring device. it provides a COM-Interface defines serveral functions to set measurement parameters and fires an event when it measured data. in order to test our software, i'm implementing a simulation of that device. the com-object runs a loop which periodically fires the event. another loop in the client app should now setup up the com-simulator using the given functions. i created a class for measuring parameters which will be instanciated when setting up a new measurement. // COM-Object public class MeasurementParams { public double Param1; public double Param2; } public class COM_Sim : ICOMDevice { public MeasurementParams newMeasurement; IClient client; public int NewMeasurement() { newMeasurment = new MeasurementParam(); } public int SetParam1(double val) { // why is newMeasurement null when method is called from client loop newMeasurement.Param1 = val; } void loop() { while(true) { // fire event client.HandleEvent; } } } public class Client : IClient { ICOMDevice server; public int HandleEvent() { // handle this event server.NewMeasurement(); server.SetParam1(0.0); } void loop() { while(true) { // do some stuff... server.NewMeasurement(); server.SetParam1(0.0); } } } both of the loops run in independent threads. when server.NewMeasurement() is called, the object on the server is set to a new instance. but in the next function, the object is null again. do the same when handling the server-event, it works perfectly, because the method runs in the servers thread. how to make it work from client-thread as well. as the client is meant to be working with the real device, i cannot modify the interfaces given by the manufactor. also i need to setup measurements independent from the event-handler, which will be fired not regulary. i assume this problem related to multithreaded-COM behavior but i found nothing on this topic.

    Read the article

  • COM Pointers and process termination

    - by Tony
    Can an unreleased COM pointer to an external process (still alive) cause that process to hang on destruction? Even with TerminateProcess called on it? Process A has a COM interface pointer reference to Process B, now Process B issues a TerminateProcess on A, if some COM interface pointer to Process B in Process A is not released properly, could it be that the process hangs on termination?

    Read the article

  • Centralised/shared COM DLL, possible?

    - by vikp
    Hi, We have a system that makes a use of 3rd party COM DLL written in vba We have a centralised web application and 1-50 client machines that must reference that COM DLL in order to use our centralised web application. The COM DLL is going to be updated rapidly in the future, which means that it has to be re-installed on every machine manually. Is it possible to centralise this COM DLL somwhere on the network? Is there any other alternatives? Otherwise the maintenance overhead will be huge... Thank you

    Read the article

  • COM on Windows7 and Visual Studio

    - by vikasde
    I registered a COM dll (under administrator) using regsvr32, which I want to use in Visual Studio 2008 (under administrator) for my project in Windows 7. Now, when I try to use the interfaces and classes from the COM, then I can't see any of the methods. When I use the object browser to view the COM classes, then I can see that they are all empty. However when I use the same COM on windows XP using VS2008, then all methods are suddenly available. Does anybody know why this is happening and how to get this working under Windows 7?

    Read the article

  • Does Scheme work with Microsoft COM?

    - by Martin
    I'm new to Scheme -- the functional programming language and I like it a lot for its first-class/higher-order functions. However, my data comes from a COM source with an object-oriented API. I know Scheme and COM belong to different programming paradigms, but I'm wondering if there is any interface or a way for Scheme to connect to a COM source? Thanks.

    Read the article

  • C# Casting system.__comobject to class type

    - by ijrufus
    I have an Excel Add-In that I'm currently trying to set up a unit test framework for. For the unit tests I've followed this guide: http://blogs.msdn.com/b/varsha/archive/2010/08/17/writing-automated-test-cases-for-vsto-application.aspx It seems to work fine, until I want to return a class object from my interface. Specifying the class object as the return type throws a "return argument has an invalid type" exception when calling the method. Changing the return type from the class to an object allows me to call the method and get the object, but now I'm unable to cast it as the class and use it as intended, getting this exception message when I try: > Unable to cast COM object of type 'System.__ComObject' to class type > 'anaplan.Utility.XYCoordinates'. Instances of types that represent COM > components cannot be cast to types that do not represent COM > components; however they can be cast to interfaces as long as the > underlying COM component supports QueryInterface calls for the IID of > the interface. I've retrieved the Type name using VisualBasic.Information.TypeName and it's showing it as the class I expect. Is there any way to get the comobject cast back to the class? Or another way to access the properties it has? Or am I just being a bit stupid here?

    Read the article

  • SQL CLR Assembly Error 80131051 when late binding to a registered C# COM .dll

    - by Shanubus
    I must have hit an unusual one, because I can't find any reference to this specific failing anywhere... Scenario: I have a legacy SQL function used to transform(encrypt) data. This function is called from within many stored procedures used by multiple applications. I say this, because the obvious answer of 'just call it from your code' is not really an option (or at least one I'd prefer not explore). The legacy function used sp_OA with an ActiveX dll on SQL2000 to perform its work. The new function is targeted at SQL2008 x64. I am ditching the sp_OA call in favor of CLR assembly; and am getting rid of the ActiveX dll and using a COM+ .dll (3rd party) to perform the same work. This 3rd party COM+ is required to be used based on spec given to me, so can't get rid of this piece either. Problem: After multiple attempts at getting this to work I have eliminated the following approaches 1) Create a Sql Assembly to call the local COM+ directly -- Can't do this as it requires a reference to System.EnterpriseServices. Including this requires that a whole slew of unsupported assemblies be registered which I don't want. The COM+ requires it's methods to be accessed via an Interface, so my attempts at late binding to it directly have not been successful (late binding would allow me to drop the unsupported references). 2) Create a Sql Assembly which references a C# class library that then calls the COM+. -- Same issue as #1; since the referenced dll uses System.EnterpriseServices and will be added as a dependency when referenced in the Sql Assembly, again trying to load all the unsupported libraries 3) Create a Sql Assembly which late binds to an ActiveX COM dll that calls the COM+. -- Worked in my dev environment, but can't go to x64 in production with ActiveX dll's written in VB6 (not to mention I hate backtracking anyway)... again failure... I am now onto an approach that is almost working, with of course one last hangup. I now have -a Sql Assembly that late binds to a C# COM dll, eliminating the need for including System.EnterpriseServices and eliminating the need to reference the C# COM in the SqlAssembly itself. The C# COM does reference System.EnterpriseServices to call the COM+, but since I am late binding to it from the SqlAssembly, I bypass the need for Sql to actually load them as referenced assemblies. Works in debugger.. Works on my dev box when the SqlAssembly dll is referenced in a test console app and called directly Installs to Sql2008 just fine Executing the actual UDF works, but returns no data due to a failure reporting from the late bound dll! So the SqlAssembly is instanciated just fine. It actually fails on it's late binding to the C# COM, which is working from a test console app on the same machine. It appears to be a difference in behavior based on whether called from within the SQL UDF or not. Since it is working on the same box from my console app, I am assuming it's on the SQL side. My steps to install were. --Install the COM+ dll and ensure it can be called successfully (as from with in the console app) --Register the C# COM dll (which calls the COM+) and get it to the GAC (again proofed to be working from console app) --Create my Assymetric Key CREATE ASYMMETRIC KEY SqlCryptoKey FROM EXECUTABLE FILE = 'D:\SqlEx.dll' CREATE LOGIN SqlExLogin FROM ASYMMETRIC KEY SqlExKey GRANT UNSAFE ASSEMBLY TO SqlExLogin GO --Add the assembly CREATE ASSEMBLY SqlEx FROM 'D:\SqlEx.dll' WITH PERMISSION_SET = UNSAFE; GO --Create the function CREATE FUNCTION dbo.f_SqlEx( @clearText [nvarchar](512) ) RETURNS nvarchar(512) WITH EXECUTE AS CALLER AS EXTERNAL NAME SqlEx.[SqlEx.SqlEx].Ex GO With all that done, I can now call my function SELECT dbo.f_SqlEx('test') But get this error in the event log... Retrieving the COM class factory for component with CLSID {F69D6320-5884-323F-936A-7657946604BE} failed due to the following error: 80131051. I can't really provide direct code examples, due to internal security implications; but all the code itself seems to work, I am suspecting perms or something of the like... I just find it odd that I can't find any reference to error 80131051. If someone out there believe some 'indirect' code samples will help, I will be happy to provide. Any assistance is appreciated.

    Read the article

  • PHP: Why Cookies only sent to http://www.xxx.com and NOT http://xxx.com

    - by Axel
    Hi, I have a php login which sets 2 cookies once some one login. the problem is that if you login from : http://www.mydomain.com and you go to http://mydomain.com you will find your self not logged in, I think that's because the browser only send the cookies to the first syntax. It's only one domain, the difference is the www. before the domain name, so how to set cookies to the whole domain whatever there is www. or not ? <?php setcookie('username',$username,time()+3600); ?> Thanks

    Read the article

  • Mysql-how to update the "domain.com" in "[email protected]"

    - by w00t
    Hi there, In my database I have a lot of users who've misspelled their e-mail address. This in turn causes my postfix to bounce a lot of mails when sending the newsletter. Forms include (but are not limited to) "yaho.com", "yahho .com" etc. Very annoying! So i have been trying to update those record to the correct value. After executing select email from users where email like '%@yaho%' and email not like '%yahoo%'; and getting the list, I'm stuck because I do not know how to update only the yaho part. I need the username to be left intact. So I thought I would just dump the database and use vim to replace, but I cannot escape the @ symbol.. BTW, how do I select all email addresses written in CAPS? select upper(email) from users; would just transform everything into CAPS, whereas I just needed to find out the already-written-in-CAPS mails.

    Read the article

  • Casing of COM-Interop registered components

    - by Marko Apfel
    During a refactoring i realized that renaming of components, which will be registered for COM-Interop, must be done carefully. In my case i changed the casing of XyzToolbar to XyzToolBar. At the developing machine everything works fine. But after installing the modified stuff at the production machine, the toolbar was not visible. Using regasm with the new assemblies helped. So this was the hint: we use WIX to build the setup. And during setup-development the heat-tool extracted the needed registry-keys. And in these keys still was the old name XyzToolbar. Refreshing the names corrected the problem.

    Read the article

  • What is this exception ?

    - by Lalit
    I am getting this exception while reading the shapes in excel sheet in c#: on code line of if (worksheet.Shapes.Count >= iCurrentRowIndex) {} Unable to cast COM object of type 'System.__ComObject' to interface type 'Microsoft.Office.Interop.Excel._Worksheet'. This operation failed because the QueryInterface call on the COM component for the interface with IID '{000208D8-0000-0000-C000-000000000046}' failed due to the following error: The application called an interface that was marshalled for a different thread. (Exception from HRESULT: 0x8001010E (RPC_E_WRONG_THREAD)).

    Read the article

  • Retrieving Data related to a top-level object from parse.com using PHP

    - by Albeert Tw
    I am retrieve related data using parse.com and PHP I get the top-leve object without problems but I can't access related data. ([myRelation] => stdClass Object ( [__type] => Relation [className] => other)) Please refer to my code below: $className = "myClass"; $url = 'https://api.parse.com/1/classes/' . $className; $appId = 'xxxxxx'; $restKey = 'xxxxxxx'; $relatedParams = urlencode('include=people'); $rest = curl_init(); curl_setopt($rest, CURLOPT_SSL_VERIFYPEER, false); curl_setopt($rest, CURLOPT_URL, $url .'/io1GzkzErH/'.$relatedParams); curl_setopt($rest, CURLOPT_HTTPGET, true); curl_setopt($rest, CURLOPT_RETURNTRANSFER, true); curl_setopt($rest, CURLOPT_HTTPHEADER, array("X-Parse-Application-Id: " . $appId, "X-Parse-REST-API-Key: " . $restKey, "Content-Type: application/json")); $response = curl_exec($rest); echo $response; I want to see related objects into myRelation. Current answer is: I get this answer: stdClass Object ( [Altres] => loremipsum. [Cartell] => stdClass Object ( [__type] => File [name] => f29efff4-5db1-451a-ab42-7569fbb955a7-cartell.jpg [url] => loremipsum.jpg ) [CartellURL] => [Categoria] => Comedia [Durada] => 120min [Estat] => Al teatre [Final] => stdClass Object ( [__type] => Date [iso] => 2014-06-18T22:00:00.000Z ) [Inici] => stdClass Object ( [__type] => Date [iso] => 2014-04-25T22:00:00.000Z ) [Nom] => Losers [Prioritat] => 0 [Sala] => loremipsum [Sinopsis] => loremipsum [TrailerURL] => loremipsum.com [URLEntrada] => loremipsum.com [URLProductora] => http://www.loremipsum.com [Visible] => 1 [createdAt] => 2014-05-20T12:01:06.094Z [objectId] => io1GzkzErH [people] => stdClass Object ( [__type] => Relation [className] => persones ) [updatedAt] => 2014-05-20T12:07:22.758Z ) loremipsum But I need to know what are in [people] = stdClass Object ( [__type] = Relation [className] = persones )

    Read the article

  • Exposing C# COM server events to Delphi client applications

    - by hectorsosajr
    My question is very similar to these two: http://stackoverflow.com/questions/1140984/c-component-events http://stackoverflow.com/questions/1638372/c-writing-a-com-server-events-not-firing-on-client However, what worked for them is not working for me. The type library file, does not have any hints of events definitions, so Delphi doesn't see it. The class works fine for other C# applications, as you would expect. COM Server tools: Visual Studio 2010 .NET 4.0 Delphi applications: Delphi 2010 Delphi 7 Here's a simplified version of the code: /// <summary> /// Call has arrived delegate. /// </summary> [ComVisible(false)] public delegate void CallArrived(object sender, string callData); /// <summary> /// Interface to expose SimpleAgent events to COM /// </summary> [ComVisible(true)] [GuidAttribute("1FFBFF09-3AF0-4F06-998D-7F4B6CB978DD")] [InterfaceType(ComInterfaceType.InterfaceIsIDispatch)] public interface IAgentEvents { ///<summary> /// Handles incoming calls from the predictive manager. ///</summary> ///<param name="sender">The class that initiated this event</param> ///<param name="callData">The data associated with the incoming call.</param> [DispId(1)] void OnCallArrived(object sender, string callData); } /// <summary> /// Represents the agent side of the system. This is usually related to UI interactions. /// </summary> [ComVisible(true)] [GuidAttribute("EF00685F-1C14-4D05-9EFA-538B3137D86C")] [ClassInterface(ClassInterfaceType.None)] [ComSourceInterfaces(typeof(IAgentEvents))] public class SimpleAgent { /// <summary> /// Occurs when a call arrives. /// </summary> public event CallArrived OnCallArrived; public SimpleAgent() {} public string AgentName { get; set; } public string CurrentPhoneNumber { get; set; } public void FireOffCall() { if (OnCallArrived != null) { OnCallArrived(this, "555-123-4567"); } } } The type library file has the definitions for the properties and methods, but no events are visible. I even opened the type library in Delphi's viewer to make sure. The Delphi app can see and use any property, methods, and functions just fine. It just doesn't see the events. I would appreciate any pointers or articles to read. Thanks!

    Read the article

  • How to solve "catastrophic failure" with 32-bit COM component in SysWOW64\cscript or wscript

    - by kcrumley
    I'm trying to run a VBScript script that uses a 7-year-old 3rd-party 32-bit COM component on Windows Server 2008 R2, with the command-line 32-bit script host, SysWOW64\cscript.exe. When I call CreateObject on the class, it appears to be successful, but the very first time I try to use a property or method (I've tried several different ones) on the object, it gives me the "catastrophic failure". I have identical results with SysWOW64\wscript.exe, except, of course, that my error message comes in a msgbox instead of the command-line window. I think this has to do specifically with the 64-bit scripting hosts because of the following: The equivalent Classic ASP script, calling the same component and using 95% of the same code, works correctly on the same server, with IIS configured to support 32-bit COM. The same VBScript works correctly on a 32-bit Windows XP machine and a 32-bit Windows Server 2003 machine. The component fails in exactly the same way on my 64-bit Windows 7 machine. My Google searches for solutions to this problem have mostly turned up a lot of different problems that were solved by putting the COM component into a toolbar in Visual Studio. Obviously, that solution doesn't apply here. My questions are: Is there a core problem that is always behind a "catastrophic failure" from a Windows scripting host calling a COM component? Is there a place in a configuration snap-in, or in the registry, where I need to make a change similar to the change I had to make to the IIS Application pool to "Enable 32-bit Applications"? Is there a general place in the Server 2008 R2 Event Viewer that I should be looking, to see if there are any more details on the failure, in case it turns out to be specific to this component? Thanks in advance.

    Read the article

  • Weird error running com-exposed assembly

    - by Bernabé Panarello
    I am facing the following issue when deploying a com-exposed assembly to my client's. The COM component should be consummed by a vb6 application. Here's how it's done 1) I have one c# project which has a class with a couple of methods exposed to COM 2) The project has references to multiple assemblies 3) I compile the project, generating a folder (named dllcom) that contains the assembly plus all the referenced dlls 4) I include in the folder a .bat which does the following: regasm /u c:\dllcom\LibInsertador.dll del LibInsertador.tlb regasm c:\dllcom\LibInsertador.dll /tlb:c:\dllcom\LibInsertador.tlb /codebase c:\dllcom\ pause 5) After running the bat locally in many workstations of my laboratory, i'm able to consume the generated tlb from my vb6 application without any problems. I'm even able to update the dll by only means of running this bat, without having to recompile the vb6 application. I mean that im not having issues of vb6 fiding and invoking the exposed com object. The problem 6) I send the SAME FOLDER to my client 7) They execute the .bat locally, without any errors 8) They execute the vb6 application, vb6 finds the main assembly, the .net code seems to run correctly (it's even able to generate a log file) until it has to intantiate it's first referenced assembly. Then, they get the following exception: "Could not load type 'GYF.Common.TypeBuilder' from assembly 'GYF_Common, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null'." Where "GYF.Common" is an assembly referenced by LibInsertador and TypeBuilder is a class contained in GYF.Common. GYF.Common is not a signed assembly and it's not in the GAC, just in the same folder with Libinsertador. According to .net reflector, the version is correct. ¿Any ideas about what could be happening?

    Read the article

  • Accessing a com object's vtable in c#

    - by Martin Booth
    I'm attempting to access a com object's vtable in memory and getting nowhere. From what I have read, the first 4 bytes in memory of a com object should be a pointer to the vtableptr, which in turn is a pointer to the vtable. Although I'm not sure I expect to find my test method at slot 7 in this com object I have tried them all and nothing looks like the address of my function. If anyone can make the necessary changes to this sample to get it to work (the aim is just to try and invoke the Test method on the Tester class by accessing the com object's vtable and locating the method in whichever row it turns up) I would be very grateful. I know it is rare that anyone would need to do this, but please accept I do need to do something quite similar and have considered the alternatives Thanks in advance [ComVisible(true)] public class Tester { public void Test() { MessageBox.Show("Here"); } } public delegate void TestDelegate(); private void main() { Tester t = new Tester(); GCHandle objectHandle = GCHandle.Alloc(t); IntPtr objectPtr = GCHandle.ToIntPtr(objectHandle); IntPtr vTable = (IntPtr)Marshal.ReadInt32(objectPtr); IntPtr vTablePtr = (IntPtr)Marshal.ReadInt32(vTable); IntPtr functionPtr = (IntPtr)Marshal.ReadInt32(vTablePtr, 7 * 4); // 7 may be incorrect but i have tried many different values TestDelegate func = (TestDelegate)Marshal.GetDelegateForFunctionPointer(functionPtr, typeof(TestDelegate)); func(); objectHandle.Free(); }

    Read the article

  • ASP.NET 2.0 and COM Port Communication

    - by theaviator
    ASP.NET 2.0 and COM Port Communication Hello Guys, I have a managed DLL which communicates with the devices attached on COM/Serial ports. The desktop Winforms application sends requests on ports and receives/stores data in memory. In Winforms app I have added a reference to DLL and I am using the methods. This works well. Now, there is a situation where I need to show this data from serial/com port on a web-page. And also users should be able to send requests to the ports using this DLL. I have made a web app in ASP.NET (2.0). Added a reference to the DLL. I am able to use this DLL, the DLL communicates on the COM upon button click on web-page and also the response is shown on web page. However I am not happy with the approach and strongly feel that this is a bad approach. Also the development server crashes after 3 -4 requests. What is the best approach in this scenario. If I use a windows service then how would my ASP.net app will communicate with the Weindows service. Or can this be easily done using WCF. I have not used WCF any time nor any of .net remoting technique. Please suggest me the best architecture in this scenario. Thank you

    Read the article

  • protecting COM interfaces from exceptions

    - by rmeador
    I have several dozen objects exposed through COM interfaces, each of which with many methods, totaling a few hundred methods. These interfaces expose business objects from my app to a scripting engine. I have been given the task of protecting every single one of these methods from exceptions being thrown (to catch them and return an error using COM's Error() function, which incidentally I can find no documentation on because it's impossible to google). To my understanding, this requires that I add a try/catch around the guts of each one of these methods. The catch blocks are going to be similar or identical for each and every one of these hundreds of methods, which strongly smells of a problem (massively violates the DRY principle), but I can't think of any way to avoid changing every method. As far as I can tell, these methods are invoked directly by COM, with no intervening code that I can hook into to catch the exceptions. My current best idea is to make a macro for the catch block, but that has it's own sort of code-smell. Can anyone come up with a better approach? BTW, my app's exceptions do not derive from std::exception, so if there is some way of COM automatically handling standard exceptions, it won't help. And I sadly cannot change the existing exceptions to derive from std::exception.

    Read the article

  • Unofficial Prep guide for TS: Microsoft Lync Server 2010, Configuring (70-664)

    - by Enrique Lima
    Managing Users and Client Access (20 percent)   Objective Materials Configure user accounts http://technet.microsoft.com/en-us/library/gg182543.aspx Deploy and maintain clients http://technet.microsoft.com/en-us/library/gg412773.aspx Configure conferencing policies http://technet.microsoft.com/en-us/library/gg182561.aspx Configure IM policies http://technet.microsoft.com/en-us/library/gg182558.aspx Deploy and maintain Lync Server 2010 devices http://technet.microsoft.com/en-us/library/gg412773.aspx Resolve client access issues http://technet.microsoft.com/en-us/library/gg398307.aspx   Configuring a Lync Server 2010 Topology (21 percent)   Objective Materials Prepare to deploy a topology http://technet.microsoft.com/en-us/library/gg398630.aspx Configure Lync Server 2010 by using Topology Builder http://technet.microsoft.com/en-us/library/gg398420.aspx Configure role-based access control in Lync Server 2010 http://technet.microsoft.com/en-us/library/gg412794.aspx http://technet.microsoft.com/en-us/library/gg425917.aspx Configure a location information server http://technet.microsoft.com/en-us/library/gg398390.aspx Configure server pools for load balancing http://technet.microsoft.com/en-us/library/gg398827.aspx   Configuring Enterprise Voice (19 percent)   Objective Materials Configure voice policies http://technet.microsoft.com/en-us/library/gg398450.aspx Configure dial plans http://technet.microsoft.com/en-us/library/gg398922.aspx Manage routing http://technet.microsoft.com/en-us/library/gg425890.aspx http://technet.microsoft.com/en-us/library/gg182596.aspx Configure Microsoft Exchange Unified Messaging integration http://technet.microsoft.com/en-us/library/gg398768.aspx Configure dial-in conferencing http://technet.microsoft.com/en-us/library/gg398600.aspx Configure call admission control http://technet.microsoft.com/en-us/library/gg520942.aspx Configure Response Group Services (RGS) http://technet.microsoft.com/en-us/library/gg398584.aspx Configure Call Park and Unassigned Number http://technet.microsoft.com/en-us/library/gg399014.aspx http://technet.microsoft.com/en-us/library/gg425944.aspx Manage a Mediation Server pool and PSTN Gateway http://technet.microsoft.com/en-us/library/gg412780.aspx   Configuring Lync Server 2010 for External Access (19 percent)   Objective Materials Configure Edge Services http://technet.microsoft.com/en-us/library/gg398918.aspx Configure a firewall http://technet.microsoft.com/en-us/library/gg425882.aspx Configure a reverse proxy http://technet.microsoft.com/en-us/library/gg425779.aspx   Monitoring and Maintaining Lync Server 2010 (21 percent)   Objective Materials Back up and restore Lync Server 2010 http://technet.microsoft.com/en-us/library/gg412771.aspx Configure monitoring and archiving http://technet.microsoft.com/en-us/library/gg398199.aspx http://technet.microsoft.com/en-us/library/gg398507.aspx http://technet.microsoft.com/en-us/library/gg520950.aspx http://technet.microsoft.com/en-us/library/gg520990.aspx Implement troubleshooting tools http://technet.microsoft.com/en-us/library/gg425800.aspx Use PowerShell to test Lync Server 2010 http://technet.microsoft.com/en-us/library/gg398474.aspx

    Read the article

  • COM Object Method Invoke Exception - Silverlight 4

    - by Adam Driscoll
    I'm trying to use the new AutomationFactory provided with Silverlight 4 to call a .NET COM class. .NET COM-Exposed Class: public class ObjectContainer { public bool GetObject([Out, MarshalAs((UnmanagedType.IUnknown)] out object obj) { obj = new SomeOtherObj(); return true; } } Silverlight Assembly: dynamic objectContainer; try { objectContainer = AutomationFactory.GetObject(ProgId); } catch { objectContainer = AutomationFactory.CreateObject(ProgId); } object obj; if (!objectContainer.GetObject(out obj)) { throw new Exception(); } When I call objectContainer.GetObject(out obj) an exception is thrown stating: Value does not fall within the expected range. at MS.Internal.ComAutomation.ComAutomationNative.CheckInvokeHResult(UInt32 hr, String memberName, String exceptionSource, String exceptionDescription, String exceptionHelpFile, UInt32 exceptionHelpContext) at MS.Internal.ComAutomation.ComAutomationNative.Invoke(Boolean tryInvoke, String memberName, ComAutomationInvokeType invokeType, ComAutomationInteropValue[] rgParams, IntPtr nativePeer, ComAutomationInteropValue& returnValue) at MS.Internal.ComAutomation.ComAutomationObject.InvokeImpl(Boolean tryInvoke, String name, ComAutomationInvokeType invokeType, Object& returnValue, Object[] args) at MS.Internal.ComAutomation.ComAutomationObject.Invoke(String name, ComAutomationInvokeType invokeType, Object[] args) at System.Runtime.InteropServices.Automation.AutomationMetaObjectProvider.TryInvokeMember(InvokeMemberBinder binder, Object[] args, Object& result) at System.Runtime.InteropServices.Automation.AutomationMetaObjectProviderBase.<.cctorb__4(Object obj, InvokeMemberBinder binder, Object[] args) at CallSite.Target(Closure , CallSite , Object , String , Object& ) at CallSite.Target(Closure , CallSite , Object , String , Object& ) at ApplicationModule.ObjectContainer.GetObject() Wha's the deal?

    Read the article

  • Question about making Asynchronous call in C# (WPF) to COM object

    - by Andrew
    Hi, Sorry to ask such a basic question but I seem to have a brain freeze on this one! I'm calling a COM (ATL) object from my WPF project. The COM method might take a long time to complete. I thought I'd try and call it asychronously. I have a few demo lines that show the problem. private void checkBox1_Checked(object sender, RoutedEventArgs e) { //DoSomeWork(); AsyncDoWork caller = new AsyncDoWork(DoSomeWork); IAsyncResult result = caller.BeginInvoke(null, null); } private delegate void AsyncDoWork(); private void DoSomeWork() { _Server.DoWork(); } The ATL method DoWork is very exciting. It is: STDMETHODIMP CSimpleObject::DoWork(void) { Sleep(5000); return S_OK; } I had expectations that running this way would result in the checkbox being checked right away (instead of in 5 seconds) and me being able to move the WPF gui around the screen. I can't - for 5 seconds. What am I doing wrong? I'm sure it's something pretty simple. Delegate signature wrong? Thanks.

    Read the article

  • How to debug applications using COM interfaces?

    - by Eric
    I' building an application using C# which will use CATIA COM modules. When I import the COM inside my c# project, I think that Visual C# express generates the Interop automagically for me. All of this works correctly. However, when I try to debug the application and use watches during runtime, every object is a System.__ComObject and I cannot get their "real" value. Is there a way to tell the debugger the types of my COM objects? The goal is to get more familiar with this new API I don't know really well. Sometimes its rather hard to guess the correct types for everything since the interface hierarchy is quite deep

    Read the article

  • Advice when using COM Object/CComPtr and the STL

    - by YoungPony
    Hello, I am doing some COM related things with directshow such as: typedef CComPtr<IBaseFilter> AutoIBaseFilterPtr; map<CString, AutoIBaseFilterPtr> _filterMap; To store a list of directShow related com objects and their friendly name. After finding this article (See:Problem 2) on how changes in VC10 compiler might effect previously OK code, I am wondering if there are any more things to watch out for when mixing the STL and CComPtr or prehaps just mixing the STL and COM in general. Any tips would be greatly appreciated, thanks

    Read the article

  • Minimum permissions to COM Object to Instantiate running as LocalService

    - by Paul Farry
    I'm writing a .NET Service that creates a COM object. If I run the Service as the Logged on user (everything is fine). If I run the Service as LocalSystem, everything is fine. If I run the Service as LocalService, then I get an AccessDeniedException when trying to instantiate the COM Object. I've come up with the following block to grant the necessary permissions and it appears to work correctly, but I wanted to make sure I wasn't missing something regarding the COM rules. Private Sub SetAccessToRockeyRegistry() Using reg As RegistryKey = Microsoft.Win32.Registry.ClassesRoot.OpenSubKey("CLSID\{EE0680D3-AAC3-446B-AFD7-F9DE2D3E28FB}", True) Dim sec As RegistrySecurity sec = reg.GetAccessControl Dim ar As RegistryAccessRule Dim sid As SecurityIdentifier sid = New SecurityIdentifier(WellKnownSidType.LocalServiceSid, Nothing) ar = New RegistryAccessRule(sid, RegistryRights.ReadKey Or RegistryRights.EnumerateSubKeys Or RegistryRights.QueryValues, AccessControlType.Allow) sec.AddAccessRule(ar) ar = New RegistryAccessRule(sid, RegistryRights.ReadKey Or RegistryRights.EnumerateSubKeys Or RegistryRights.QueryValues, _ InheritanceFlags.ObjectInherit Or InheritanceFlags.ContainerInherit, PropagationFlags.InheritOnly Or PropagationFlags.NoPropagateInherit, AccessControlType.Allow) sec.AddAccessRule(ar) reg.SetAccessControl(sec) End Using End Sub

    Read the article