Search Results

Search found 18865 results on 755 pages for 'distinct values'.

Page 137/755 | < Previous Page | 133 134 135 136 137 138 139 140 141 142 143 144  | Next Page >

  • SQL Database Schema Design For Large 3 Billion Relationship Database.

    - by K-Bell
    Get your geek on. Can you solve this? I am designing a products database for SQL Server 2008 R2 Ed. (not Enterprise Ed.) that will be used to store custom product configurations for over 30,000 distinct products. The database will have up to 500 users at a time. Here is the design problem… Each Product has a collection of Parts (up to 50 parts per product). So if I have 30,000 Products and each of them can have up to 50 Parts, that’s 1.5 million distinct Product-to-Part relationships …or as an equation… 30,000 (Products) X 50 (Parts) = 1.5 million Product-to-Parts records. …and If… Each Part can have up to 2000 finish options (A finish is a paint color). NOTE: Only one finish will be selected by a user at run-time. The 2000 finish options I need to store are the allowed options for a specific part on a specific product. So if I have 1.5 million distinct product-to-part relationships/records and each of those parts can have up to 2,000 finishes that is 3 billion allowable product-to-part-to finish relationships/records …or as an equation… 1.5 million (Parts) x 2,000 (Finishes) = 3 Billion Product-to-Part-to-Finishes records. How can I design this database so that I can execute fast and efficient queries for a specific product and return its list of Parts and all the allowable Finishes for each part without 3 Billion Product-to-Part-to-Finish records? Read time is more important then write time. Please post your thoughts/suggestions if you have experience with large databases. Thanks!

    Read the article

  • Refactoring two methods down to one

    - by bflemi3
    I have two methods that almost do the same thing. They get a List<XmlNode> based on state OR state and schoolType and then return a distinct, ordered IEnumerable<KeyValuePair<string,string>>. I know they can be refactored but I'm struggling to determine what type the parameter should be for the linq statement in the return of the method (the last line of each method). I thank you for your help in advance. private IEnumerable<KeyValuePair<string, string>> getAreaDropDownDataSource() { StateInfoXmlDocument stateInfoXmlDocument = new StateInfoXmlDocument(); string schoolTypeXmlPath = string.Format(STATE_AND_SCHOOL_TYPE_XML_PATH, StateOfInterest, ConnectionsLearningSchoolType); var schoolNodes = new List<XmlNode>(stateInfoXmlDocument.SelectNodes(schoolTypeXmlPath).Cast<XmlNode>()); return schoolNodes.Select(x => new KeyValuePair<string, string>(x.Attributes["idLocation"].Value, x.Value)).OrderBy(x => x.Key).Distinct(); } private IEnumerable<KeyValuePair<string, string>> getStateOfInterestDropDownDataSource() { StateInfoXmlDocument stateInfoXmlDocument = new StateInfoXmlDocument(); string schoolTypeXmlPath = string.Format(SCHOOL_TYPE_XML_PATH, ConnectionsLearningSchoolType); var schoolNodes = new List<XmlNode>(stateInfoXmlDocument.SelectNodes(schoolTypeXmlPath).Cast<XmlNode>()); return schoolNodes.Select(x => new KeyValuePair<string, string>(x.Attributes["stateCode"].Value, x.Attributes["stateName"].Value)).OrderBy(x => x.Key).Distinct(); }

    Read the article

  • SELECT Statement without duplicate rows on the multiple join tables

    - by theBo
    I have 4 tables built with JOINS and I would like to SELECT DISTINCT rows on the setsTbl.s_id so they always show regardless if there's relational data against them or not!. This is what I have at present which displays the data but doesn't display all of but not the entire distinct row! SELECT setsTbl.s_id, setsTbl.setName, userProfilesTbl.no + ' ' + userProfilesTbl.surname AS Name, trainingTbl.t_date, userAssessmentTbl.o_id FROM userProfilesTbl LEFT OUTER JOIN userAssessmentTbl ON userProfilesTbl.UserId = userAssessmentTbl.UserId FULL OUTER JOIN trainingTbl ON userAssessmentTbl.tt_id = trainingTbl.tt_id RIGHT OUTER JOIN setsTbl ON trainingTbl.s_id = setsTbl.s_id WHERE (userProfilesTbl.st_id=@st_id AND userProfilesTbl.sh_id=@sh_id) AND (DATEPART(yyyy,t_date) = @y_date ) OR (userAssessmentTbl.o_id IS NULL) ORDER BY setName ASC, t_date ASC With this statement I get some of the rows (the ones with data against them) but as stated the s_id field does not return distinct. This following inner select statement works in part when used in SQL Query analyzer and returns pretty much the data i require s_id setName Name o_id ----- ----- ----- ------ 1 100 Barnes 2 2 100 Beardsley 3 3 101 Aldridge 1 4 102 Molby 2 5 102 Whelan 3 but not when used outside of that environment. select * from ( SELECT userProfilesTbl.serviceNo + ' ' + userProfilesTbl.surname AS Name, userProfilesTbl.st_id, userProfilesTbl.sh_id, userAssessmentTbl.o_id, setsTbl.s_id, setsTbl.setName, row_number() over ( partition by setsTbl.s_id order by setsTbl.s_id ) r FROM userProfilesTbl LEFT OUTER JOIN userAssessmentTbl ON userProfilesTbl.UserId = userAssessmentTbl.UserId FULL OUTER JOIN trainingTbl ON userAssessmentTbl.tt_id = trainingTbl.tt_id RIGHT OUTER JOIN setsTbl ON trainingTbl.s_id = setsTbl.s_id ) x where x.r = 1 Not receiving any errors just not displaying the data?

    Read the article

  • Use combobox value as query value (VC# 2k8 / ADO SQLITE)

    - by nicodevil
    Hi, I'm a newbie in VC# and ADO SQLITE... I'm trying to change the content of a combobox according to the value present in another one... My problem is here : SQLiteCommand cmd3 = new SQLiteCommand("select distinct(ACTION) from ACTION_LIST where CATEGORY='comboBox1.text'", conn2); What to use to do the job ? Here 'comboBox1.text' is see as a sentence not a variable... Here is the code : private void Form1_Load(object sender, EventArgs e) { using (SQLiteConnection conn1 = new SQLiteConnection(@"Data Source = Data\MRIS_DB_MASTER")) { conn1.Open(); SQLiteCommand cmd2 = new SQLiteCommand("select distinct(CATEGORY) from ACTION_LIST", conn1); SQLiteDataAdapter adapter1 = new SQLiteDataAdapter(cmd2); DataTable tbl1 = new DataTable(); adapter1.Fill(tbl1); comboBox1.DataSource = tbl1; comboBox1.DisplayMember = "CATEGORY"; adapter1.Dispose(); cmd2.Dispose(); } using (SQLiteConnection conn2 = new SQLiteConnection(@"Data Source = Data\MRIS_DB_MASTER")) { conn2.Open(); SQLiteCommand cmd3 = new SQLiteCommand("select distinct(ACTION) from ACTION_LIST where CATEGORY='comboBox1.text'", conn2); SQLiteDataAdapter adapter2 = new SQLiteDataAdapter(cmd3); DataTable tbl2 = new DataTable(); adapter2.Fill(tbl2); comboBox2.DataSource = tbl2; comboBox2.DisplayMember = "ACTION"; adapter2.Dispose(); cmd3.Dispose(); } } Thanks regards

    Read the article

  • SQL SERVER – 2008 – Introduction to Snapshot Database – Restore From Snapshot

    - by pinaldave
    Snapshot database is one of the most interesting concepts that I have used at some places recently. Here is a quick definition of the subject from Book On Line: A Database Snapshot is a read-only, static view of a database (the source database). Multiple snapshots can exist on a source database and can always reside on the same server instance as the database. Each database snapshot is consistent, in terms of transactions, with the source database as of the moment of the snapshot’s creation. A snapshot persists until it is explicitly dropped by the database owner. If you do not know how Snapshot database work, here is a quick note on the subject. However, please refer to the official description on Book-on-Line for accuracy. Snapshot database is a read-only database created from an original database called the “source database”. This database operates at page level. When Snapshot database is created, it is produced on sparse files; in fact, it does not occupy any space (or occupies very little space) in the Operating System. When any data page is modified in the source database, that data page is copied to Snapshot database, making the sparse file size increases. When an unmodified data page is read in the Snapshot database, it actually reads the pages of the original database. In other words, the changes that happen in the source database are reflected in the Snapshot database. Let us see a simple example of Snapshot. In the following exercise, we will do a few operations. Please note that this script is for demo purposes only- there are a few considerations of CPU, DISK I/O and memory, which will be discussed in the future posts. Create Snapshot Delete Data from Original DB Restore Data from Snapshot First, let us create the first Snapshot database and observe the sparse file details. USE master GO -- Create Regular Database CREATE DATABASE RegularDB GO USE RegularDB GO -- Populate Regular Database with Sample Table CREATE TABLE FirstTable (ID INT, Value VARCHAR(10)) INSERT INTO FirstTable VALUES(1, 'First'); INSERT INTO FirstTable VALUES(2, 'Second'); INSERT INTO FirstTable VALUES(3, 'Third'); GO -- Create Snapshot Database CREATE DATABASE SnapshotDB ON (Name ='RegularDB', FileName='c:\SSDB.ss1') AS SNAPSHOT OF RegularDB; GO -- Select from Regular and Snapshot Database SELECT * FROM RegularDB.dbo.FirstTable; SELECT * FROM SnapshotDB.dbo.FirstTable; GO Now let us see the resultset for the same. Now let us do delete something from the Original DB and check the same details we checked before. -- Delete from Regular Database DELETE FROM RegularDB.dbo.FirstTable; GO -- Select from Regular and Snapshot Database SELECT * FROM RegularDB.dbo.FirstTable; SELECT * FROM SnapshotDB.dbo.FirstTable; GO When we check the details of sparse file created by Snapshot database, we will find some interesting details. The details of Regular DB remain the same. It clearly shows that when we delete data from Regular/Source DB, it copies the data pages to Snapshot database. This is the reason why the size of the snapshot DB is increased. Now let us take this small exercise to  the next level and restore our deleted data from Snapshot DB to Original Source DB. -- Restore Data from Snapshot Database USE master GO RESTORE DATABASE RegularDB FROM DATABASE_SNAPSHOT = 'SnapshotDB'; GO -- Select from Regular and Snapshot Database SELECT * FROM RegularDB.dbo.FirstTable; SELECT * FROM SnapshotDB.dbo.FirstTable; GO -- Clean up DROP DATABASE [SnapshotDB]; DROP DATABASE [RegularDB]; GO Now let us check the details of the select statement and we can see that we are successful able to restore the database from Snapshot Database. We can clearly see that this is a very useful feature in case you would encounter a good business that needs it. I would like to request the readers to suggest more details if they are using this feature in their business. Also, let me know if you think it can be potentially used to achieve any tasks. Complete Script of the afore- mentioned operation for easy reference is as follows: USE master GO -- Create Regular Database CREATE DATABASE RegularDB GO USE RegularDB GO -- Populate Regular Database with Sample Table CREATE TABLE FirstTable (ID INT, Value VARCHAR(10)) INSERT INTO FirstTable VALUES(1, 'First'); INSERT INTO FirstTable VALUES(2, 'Second'); INSERT INTO FirstTable VALUES(3, 'Third'); GO -- Create Snapshot Database CREATE DATABASE SnapshotDB ON (Name ='RegularDB', FileName='c:\SSDB.ss1') AS SNAPSHOT OF RegularDB; GO -- Select from Regular and Snapshot Database SELECT * FROM RegularDB.dbo.FirstTable; SELECT * FROM SnapshotDB.dbo.FirstTable; GO -- Delete from Regular Database DELETE FROM RegularDB.dbo.FirstTable; GO -- Select from Regular and Snapshot Database SELECT * FROM RegularDB.dbo.FirstTable; SELECT * FROM SnapshotDB.dbo.FirstTable; GO -- Restore Data from Snapshot Database USE master GO RESTORE DATABASE RegularDB FROM DATABASE_SNAPSHOT = 'SnapshotDB'; GO -- Select from Regular and Snapshot Database SELECT * FROM RegularDB.dbo.FirstTable; SELECT * FROM SnapshotDB.dbo.FirstTable; GO -- Clean up DROP DATABASE [SnapshotDB]; DROP DATABASE [RegularDB]; GO Reference : Pinal Dave (http://blog.SQLAuthority.com) Filed under: SQL, SQL Authority, SQL Backup and Restore, SQL Data Storage, SQL Query, SQL Server, SQL Tips and Tricks, SQLServer, T SQL, Technology

    Read the article

  • MD5 implementation notes

    - by vaasu
    While going through RFC1321, I came across the following paragraph: This step uses a 64-element table T[1 ... 64] constructed from the sine function. Let T[i] denote the i-th element of the table, which is equal to the integer part of 4294967296 times abs(sin(i)), where i is in radians. The elements of the table are given in the appendix. From what I understood from paragraph, it means T[i] = Integer_part(4294967296 times abs(sin(i))) We know the following is true for all x: 0 <= sin(x) <= 1 Since i is an integer, abs(sin(i)) may very well be 0 for all values of i. That means table will contain all zero values ( 4294967296 times 0 is 0). In the implementation, this is not true. Why is this so? Appendix contains just the raw values after calculation. It does not show how it is derived from the sine function.

    Read the article

  • Zend - unable to catch exception [closed]

    - by coder3
    This still throw an uncaught exception.. Any insight why this isn't working? protected function login() { $cart = $this->getHelper('GetCurrentCart'); $returnValue = false; if ($this->view->form->isValid($this->_getAllParams())) { $values = $this->view->form->getValues(); try { $this->goreg = $this->goregFactory->create($this->config->goreg->service_url); if ($this->goreg->login($values['username'], $values['password']) && $this->goregSession->isLoggedIn()) { $returnValue = true; } else { echo 'success 1'; } } catch (Exception $e) { echo 'error 1'; } catch (Zend_Exception $e) { echo 'error 2'; } catch (Zend_Http_Client_Exception $e) { echo 'error 3'; } } return $returnValue; }

    Read the article

  • Timeout Considerations for Solicit Response – Part 2

    - by Michael Stephenson
    To follow up a previous article about timeouts and how they can affect your application I have extended the sample we were using to include WCF. I will execute some test scenarios and discuss the results. The sample We begin by consuming exactly the same web service which is sitting on a remote server. This time I have created a .net 3.5 application which will consume the web service using the basichttp binding. To show you the configuration for the consumption of this web service please refer to the below diagram. You can see like before we also have the connectionManagement element in the configuration file. I have added a WCF service reference (also using the asynchronous proxy methods) and have the below code sample in the application which will asynchronously make the web service calls and handle the responses on a call back method invoked by a delegate. If you have read the previous article you will notice that the code is almost the same.   Sample 1 – WCF with Default Timeouts In this test I set about recreating the same scenario as previous where we would run the test but this time using WCF as the messaging component. For the first test I would use the default configuration settings which WCF had setup when we added a reference to the web service. The timeout values for this test are: closeTimeout="00:01:00" openTimeout="00:01:00" receiveTimeout="00:10:00" sendTimeout="00:01:00"   The Test We simulated 21 calls to the web service Test Results The client-side trace is as follows:   The server-side trace is as follows: Some observations on the results are as follows: The timeouts happened quicker than in the previous tests because some calls were timing out before they attempted to connect to the server The first few calls that timed out did actually connect to the server and did execute successfully on the server   Test 2 – Increase Open Connection Timeout & Send Timeout In this test I wanted to increase both the send and open timeout values to try and give everything a chance to go through. The timeout values for this test are: closeTimeout="00:01:00" openTimeout="00:10:00" receiveTimeout="00:10:00" sendTimeout="00:10:00"   The Test We simulated 21 calls to the web service   Test Results The client side trace for this test was   The server-side trace for this test was: Some observations on this test are: This test proved if the timeouts are high enough everything will just go through   Test 3 – Increase just the Send Timeout In this test we wanted to increase just the send timeout. The timeout values for this test are: closeTimeout="00:01:00" openTimeout="00:01:00" receiveTimeout="00:10:00" sendTimeout="00:10:00"   The Test We simulated 21 calls to the web service   Test Results The below is the client side trace The below is the server side trace Some observations on this test are: In this test from both the client and server perspective everything ran through fine The open connection timeout did not seem to have any effect   Test 4 – Increase Just the Open Connection Timeout In this test I wanted to validate the change to the open connection setting by increasing just this on its own. The timeout values for this test are: closeTimeout="00:01:00" openTimeout="00:10:00" receiveTimeout="00:10:00" sendTimeout="00:01:00"   The Test We simulated 21 calls to the web service Test Results The client side trace was The server side trace was Some observations on this test are: In this test you can see that the open connection which relates to opening the channel timeout increase was not the thing which stopped the calls timing out It's the send of data which is timing out On the server you can see that the successful few calls were fine but there were also a few calls which hit the server but timed out on the client You can see that not all calls hit the server which was one of the problems with the WSE and ASMX options   Test 5 – Smaller Increase in Send Timeout In this test I wanted to make a smaller increase to the send timeout than previous just to prove that it was the key setting which was controlling what was timing out. The timeout values for this test are: openTimeout="00:01:00" receiveTimeout="00:10:00" sendTimeout="00:02:30"   The Test We simulated 21 calls to the web service Test Results The client side trace was   The server side trace was Some observations on this test are: You can see that most of the calls got through fine On the client you can see that call 20 timed out but still hit the server and executed fine.   Summary At this point between the two articles we have quite a lot of scenarios showing the different way the timeout setting have played into our original performance issue, and now we can see how WCF could offer an improved way to handle the problem. To summarise the differences in the timeout properties for the three technology stacks: ASMX The timeout value only applies to the execution time of your request on the server. The timeout does not consider how long your code might be waiting client side to get a connection. WSE The timeout value includes both the time to obtain a connection and also the time to execute the request. A timeout will not be thrown as an error until an attempt to connect to the server is made. This means a 40 second timeout setting may not throw the error until 60 seconds when the connection to the server is made. If the connection to the server is made you should be aware that your message will be processed and you should design for this. WCF The WCF send timeout is the setting most equivalent to the settings we were looking at previously. Like WSE this setting the counter includes the time to get a connection as well as the time to execute on a server. Unlike WSE and ASMX an error will be thrown as soon as the send timeout from making your call from user code has elapsed regardless of whether we are waiting for a connection or have an open connection to the server. This may to a user appear to have better latency in getting an error response compared to WSE or ASMX.

    Read the article

  • Getting started with Oracle Database In-Memory Part III - Querying The IM Column Store

    - by Maria Colgan
    In my previous blog posts, I described how to install, enable, and populate the In-Memory column store (IM column store). This weeks post focuses on how data is accessed within the IM column store. Let’s take a simple query “What is the most expensive air-mail order we have received to date?” SELECT Max(lo_ordtotalprice) most_expensive_order FROM lineorderWHERE  lo_shipmode = 5; The LINEORDER table has been populated into the IM column store and since we have no alternative access paths (indexes or views) the execution plan for this query is a full table scan of the LINEORDER table. You will notice that the execution plan has a new set of keywords “IN MEMORY" in the access method description in the Operation column. These keywords indicate that the LINEORDER table has been marked for INMEMORY and we may use the IM column store in this query. What do I mean by “may use”? There are a small number of cases were we won’t use the IM column store even though the object has been marked INMEMORY. This is similar to how the keyword STORAGE is used on Exadata environments. You can confirm that the IM column store was actually used by examining the session level statistics, but more on that later. For now let's focus on how the data is accessed in the IM column store and why it’s faster to access the data in the new column format, for analytical queries, rather than the buffer cache. There are four main reasons why accessing the data in the IM column store is more efficient. 1. Access only the column data needed The IM column store only has to scan two columns – lo_shipmode and lo_ordtotalprice – to execute this query while the traditional row store or buffer cache has to scan all of the columns in each row of the LINEORDER table until it reaches both the lo_shipmode and the lo_ordtotalprice column. 2. Scan and filter data in it's compressed format When data is populated into the IM column it is automatically compressed using a new set of compression algorithms that allow WHERE clause predicates to be applied against the compressed formats. This means the volume of data scanned in the IM column store for our query will be far less than the same query in the buffer cache where it will scan the data in its uncompressed form, which could be 20X larger. 3. Prune out any unnecessary data within each column The fastest read you can execute is the read you don’t do. In the IM column store a further reduction in the amount of data accessed is possible due to the In-Memory Storage Indexes(IM storage indexes) that are automatically created and maintained on each of the columns in the IM column store. IM storage indexes allow data pruning to occur based on the filter predicates supplied in a SQL statement. An IM storage index keeps track of minimum and maximum values for each column in each of the In-Memory Compression Unit (IMCU). In our query the WHERE clause predicate is on the lo_shipmode column. The IM storage index on the lo_shipdate column is examined to determine if our specified column value 5 exist in any IMCU by comparing the value 5 to the minimum and maximum values maintained in the Storage Index. If the value 5 is outside the minimum and maximum range for an IMCU, the scan of that IMCU is avoided. For the IMCUs where the value 5 does fall within the min, max range, an additional level of data pruning is possible via the metadata dictionary created when dictionary-based compression is used on IMCU. The dictionary contains a list of the unique column values within the IMCU. Since we have an equality predicate we can easily determine if 5 is one of the distinct column values or not. The combination of the IM storage index and dictionary based pruning, enables us to only scan the necessary IMCUs. 4. Use SIMD to apply filter predicates For the IMCU that need to be scanned Oracle takes advantage of SIMD vector processing (Single Instruction processing Multiple Data values). Instead of evaluating each entry in the column one at a time, SIMD vector processing allows a set of column values to be evaluated together in a single CPU instruction. The column format used in the IM column store has been specifically designed to maximize the number of column entries that can be loaded into the vector registers on the CPU and evaluated in a single CPU instruction. SIMD vector processing enables the Oracle Database In-Memory to scan billion of rows per second per core versus the millions of rows per second per core scan rate that can be achieved in the buffer cache. I mentioned earlier in this post that in order to confirm the IM column store was used; we need to examine the session level statistics. You can monitor the session level statistics by querying the performance views v$mystat and v$statname. All of the statistics related to the In-Memory Column Store begin with IM. You can see the full list of these statistics by typing: display_name format a30 SELECT display_name FROM v$statname WHERE  display_name LIKE 'IM%'; If we check the session statistics after we execute our query the results would be as follow; SELECT Max(lo_ordtotalprice) most_expensive_order FROM lineorderWHERE lo_shipmode = 5; SELECT display_name FROM v$statname WHERE  display_name IN ('IM scan CUs columns accessed',                        'IM scan segments minmax eligible',                        'IM scan CUs pruned'); As you can see, only 2 IMCUs were accessed during the scan as the majority of the IMCUs (44) in the LINEORDER table were pruned out thanks to the storage index on the lo_shipmode column. In next weeks post I will describe how you can control which queries use the IM column store and which don't. +Maria Colgan

    Read the article

  • What's the better user experience: Waiting once at startup for a long time or waiting frequently for a short time?

    - by Roflcoptr
    I'm currently design an application that involves a lot of calculation. Now I have generally two possibilities which I have both tested: 1) During startup of the application I calculated only the most important values and these values that consume a lot of time. So the user has to wait approximately 15 seconds during startup. But on the other hand a lot of user interactions require recalculation so that the user often has to wait 2-3 seconds after clicking somewhere until the application has calculated and loaded all values 2) I load everything during startup. This takes from 90 to 120 seconds... This is quite a long time, but the big advantage is that all the user interactions are executed immediately. So what would you generally consider the better approach? Loading all time-consuming operations during startup or when needed?

    Read the article

  • Integrating Windows Form Click Once Application into SharePoint 2007 &ndash; Part 2 of 4

    - by Kelly Jones
    In my last post, I explained why we decided to use a Click Once application to solve our business problem. To quickly review, we needed a way for our business users to upload documents to a SharePoint 2007 document library in mass, set the meta data, set the permissions per document, and to do so easily. Let’s look at the pieces that make up our solution.  First, we have the Windows Form application.  This app is deployed using Click Once and calls SharePoint web services in order to upload files and then calls web services to set the meta data (SharePoint columns and permissions).  Second, we have a custom action.  The custom action is responsible for providing our users a link that will launch the Windows app, as well as passing values to it via the query string.  And lastly, we have the web services that the Windows Form application calls.  For our solution, we used both out of the box web services and a custom web service in order to set the column values in the document library as well as the permissions on the documents. Now, let’s look at the technical details of each of these pieces.  (All of the code is downloadable from here: )   Windows Form application deployed via Click Once The Windows Form application, called “Custom Upload”, has just a few classes in it: Custom Upload -- the form FileList.xsd -- the dataset used to track the names of the files and their meta data values SharePointUpload -- this class handles uploading the file SharePointUpload uses an HttpWebRequest to transfer the file to the web server. We had to change this code from a WebClient object to the HttpWebRequest object, because we needed to be able to set the time out value.  public bool UploadDocument(string localFilename, string remoteFilename) { bool result = true; //Need to use an HttpWebRequest object instead of a WebClient object // so we can set the timeout (WebClient doesn't allow you to set the timeout!) HttpWebRequest req = (HttpWebRequest)WebRequest.Create(remoteFilename); try { req.Method = "PUT"; req.Timeout = 60 * 1000; //convert seconds to milliseconds req.AllowWriteStreamBuffering = true; req.Credentials = System.Net.CredentialCache.DefaultCredentials; req.SendChunked = false; req.KeepAlive = true; Stream reqStream = req.GetRequestStream(); FileStream rdr = new FileStream(localFilename, FileMode.Open, FileAccess.Read); byte[] inData = new byte[4096]; int bytesRead = rdr.Read(inData, 0, inData.Length); while (bytesRead > 0) { reqStream.Write(inData, 0, bytesRead); bytesRead = rdr.Read(inData, 0, inData.Length); } reqStream.Close(); rdr.Close(); System.Net.HttpWebResponse response = (HttpWebResponse)req.GetResponse(); if (response.StatusCode != HttpStatusCode.OK && response.StatusCode != HttpStatusCode.Created) { String msg = String.Format("An error occurred while uploading this file: {0}\n\nError response code: {1}", System.IO.Path.GetFileName(localFilename), response.StatusCode.ToString()); LogWarning(msg, "2ACFFCCA-59BA-40c8-A9AB-05FA3331D223"); result = false; } } catch (Exception ex) { LogException(ex, "{E9D62A93-D298-470d-A6BA-19AAB237978A}"); result = false; } return result; } The class also contains the LogException() and LogWarning() methods. When the application is launched, it parses the query string for some initial values.  The query string looks like this: string queryString = "Srv=clickonce&Sec=N&Doc=DMI&SiteName=&Speed=128000&Max=50"; This Srv is the path to the server (my Virtual Machine is name “clickonce”), the Sec is short for security – meaning HTTPS or HTTP, the Doc is the shortcut for which document library to use, and SiteName is the name of the SharePoint site.  Speed is used to calculate an estimate for download speed for each file.  We added this so our users uploading documents would realize how long it might take for clients in remote locations (using slow WAN connections) to download the documents. The last value, Max, is the maximum size that the SharePoint site will allow documents to be.  This allowed us to give users a warning that a file is too large before we even attempt to upload it. Another critical piece is the meta data collection.  We organized our site using SharePoint content types, so when the app loads, it gets a list of the document library’s content types.  The user then select one of the content types from the drop down list, and then we query SharePoint to get a list of the fields that make up that content type.  We used both an out of the box web service, and one that we custom built, in order to get these values. Once we have the content type fields, we then add controls to the form.  Which type of control we add depends on the data type of the field.  (DateTime pickers for date/time fields, etc)  We didn’t write code to cover every data type, since we were working with a limited set of content types and field data types. Here’s a screen shot of the Form, before and after someone has selected the content types and our code has added the custom controls:     The other piece of meta data we collect is the in the upper right corner of the app, “Users with access”.  This box lists the different SharePoint Groups that we have set up and by checking the boxes, the user can set the permissions on the uploaded documents. All of this meta data is collected and submitted to our custom web service, which then sets the values on the documents on the list.  We’ll look at these web services in a future post. In the next post, we’ll walk through the Custom Action we built.

    Read the article

  • How web server choose between unicode and utf-8 for accentued characters?

    - by jacques
    I have a web server with my ISP which replaces in the urls the accentued characters by their unicode values: for instance é (eacute) is translated to %e9 (dec 233). For testing I use locally Easyphp which translate those characters by their utf-8 equivalence: é is then replaced by the well known sequence %c3%a9 (é)... Browsers served by Easyphp don't decode unicode values but they do if running locally (utf-8 and non converted accent also)... I have been unable to find where this behavior is configured in the server. This is a problem as some urls are built by my application using the php rawurlencode() which seems to always encode with unicode values on both servers. Any idea? Thanks in advance.

    Read the article

  • How does the web server choose between unicode and utf-8 for accented characters?

    - by jacques
    I have a web server with my ISP which replaces accented characters in URLs with their unicode values: for instance é (eacute) is translated to %e9 (dec 233). For testing locally I use EasyPHP which translates those characters by their utf-8 equivalence: é is then replaced by the well known sequence %c3%a9 (é)... Browsers served by EasyPHP don't decode unicode values but they do if running locally (utf-8 and non converted accent also)... I have been unable to find where this behavior is configured in the server. This is a problem as some urls are built by my application using the php rawurlencode() which seems to always encode with unicode values on both servers. Any idea?

    Read the article

  • Evaluating mean and std as simulations are added

    - by Luca Cerone
    I have simulations that evaluate a certain value X. I run the simulations several times and save the value of X in a vector V. When all the runs have finished I evaluate the mean and standard deviation for the vector V. This approach works, but implies saving all the values for X. As my computer is quite old and with limited ram, I was wondering if there is a way to update the mean value M and the standard deviation S, knowing the value of X at the (n+1)-th run, and the values of M and S after n runs. How can I update the mean value and the standard deviation as simulations are added to the set? Please note that this is just a conceptual example, I don't save only one number X but thousands at each simulations, so I really have problems running a big number of runs if I have to keep all the past values into the memory.

    Read the article

  • Nicest way to map rgb colors from html to led

    - by back_ache
    I have attached an rgb led to a color picker on a webpage and have hit the obvious problem that though the led is 8-bit like html the color rendition is very different so with the more subtle shades the led values for the color are wildly different to the html values. The brute-force method would be for me to have a lookup-table on the webserver to map the two sets of values but would ideally like to do it more elegantly Before I start listing all my 101 ideas for doing this I wondered if anyone else had come across the issue, the end-game would be to be able to abstract the color-rendition of different leds and make it available as a webservice (html value and device id in, led value out)

    Read the article

  • Strategies to Defeat Memory Editors for Cheating - Desktop Games

    - by ashes999
    I'm assuming we're talking about desktop games -- something the player downloads and runs on their local computer. Many are the memory editors that allow you to detect and freeze values, like your player's health. How do you prevent cheating? What strategies are effective to combat this kind of cheating? I'm looking for some good ones. Two I use that are mediocre are: Displaying values as a percentage instead of the number (eg. 46/50 = 92% health) A low-level class that holds values in an array and moves them with each change

    Read the article

  • How to use the float value from Noise function in voxel terrain?

    - by therealjohn
    Im using Unity, although this question is not really specific to that engine. Im also using an asset from the store called Coherent Noise. It has some neat noise functionality built it. I am using those functions to produce some noise values. I am getting a value between 0 and 1 (floats). I have an array of blocks (for minecraft like voxel terrain) and I am confused on how to use this float value for terrain? Do I do something like <= 0 == Solid block etc etc? I am confused on how to use the floating values that the noise functions produce to use for height values of an array of say a height of 16. Thanks for any guidance.

    Read the article

  • Using PHP Redirect Script together with Custom Fields (WordPress)? [on hold]

    - by Alex Scherer
    I am currently trying to make yoast's link cloaking script ( Yoast.com script manual // Github Script files ) work together with the Wordpress plugin Advanced Custom Fields. The script fetches 2 values (redirect id, redirect url) via GET and then redirects to this particular URL which is defined in a .txt file called redirects.txt I would like to change the script, so that I can define both the id and redirection URL via custom fields on each post in my WP dashboard.. I would be really happy if someone could help me to code something that does the same as the script above but without using a redirects.txt file to save the values but furthermore gets those values from custom fields. Best regards ! Alex

    Read the article

  • What is a good way to keep track of strings for dictionary lookups?

    - by Justin
    I am working through the Windows 8 app tutorial. They have some code about saving app data like so: private void NameInput_TextChanged(object sender, TextChangedEventArgs e) { Windows.Storage.ApplicationDataContainer roamingSettings = Windows.Storage.ApplicationData.Current.RoamingSettings; roamingSettings.Values["userName"] = nameInput.Text; } I have worked with C# in the past and found that things like using constant string values (like "userName" in this case) for keys could get messy because auto-complete did not work and it was easy to forget if I had made an entry for a setting before and what it was called. So if I don't touch code for awhile I end up accidentally creating multiple entries for the same value that are named slightly differently. Surely there is a better way to keep track of the strings that key to those values. What is a good solution to this problem?

    Read the article

  • SSRS 2008 R2 KPIs with bullet graphs

    Key Performance Indicators are typically displayed in a scorecard with stop light indicators, which are either red, amber or green light icons. The limitation for these kind of indicators is that you can see the actual and target values in two different fields as well as see the status of the KPI in red, amber or green color. If the user wants to figure out the thresholds associated with the KPI, these values are generally not visible. Further, representing the threshold values in the scorecard itself defeats the purpose of the scorecard. The scorecard should display the KPI's status in the most summarized form and use a minimal amount of space on the dashboard. In this tip we would look at how to address this issue.

    Read the article

  • Intro to Sessions in ASP.Net

    Sessions are used to pass the value from one page to another with no effort from the user. With a session, if the user inputs values on the original page and you need to access them on another page, you can retrieve the values stored in the session without making the user submit those values again. Sessions are important to any user-related authentication (if you're using the https protocol), user-related validation and customization of visitor experiences in your website. This tutorial will use Visual Basic to illustrate ASP.NET sessions, though the code can be converted to equivalent C# code...

    Read the article

  • Cannot save all of the property settings for this Web Part.

    - by ybbest
    I would like to display all the items of custom content type of Animals in a SharePoint content query WebPart. After choosing the appropriate values in the web part editor and click on Save I got this error: Cannot save all of the property settings for this Web Part. There is a problem with one or more of the field values below. But when I examine all the values below , it does not flag any error information. I finally manage to locate the error flag after I expand the presentation section. I then delete the text in the Link textbox , now I can save the settings. However , I think the error message should have been more specific so that users can quickly locate the error. The worst part for this is that I did not even change anything in the presentation section, I merely configure the Source in the Query section. Well, I guess I am still new to SharePoint, I just have to get used to these generic error message ):

    Read the article

  • ASP.NET Pivot Grid Control Supports New Layout - v2010 vol 1

    The ASPxPivotGrid will now support a slick new feature that will help save you screen space: Compact Layout for Hierarchical Row Values With DXperience v2010 vol 1, you can create compact layouts for hierarchical pivot table row values (this capability is also available in the WinForms and WPF versions of this control). The compact layout allows you get more space horizontally without sacrificing the distinction between the hierarchical row values: DXperience? What's That? DXperience is the...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Using PhysX, how can I predict where I will need to generate procedural terrain collision shapes?

    - by Sion Sheevok
    In this situation, I have terrain height values I generate procedurally. For rendering, I use the camera's position to generate an appropriate sized height map. For collision, however, I need to have height fields generated in areas where objects may intersect. My current potential solution, which may be naive, is to iterate over all "awake" physics actors, use their bounds/extents and velocities to generate spheres in which they may reside after a physics update, then generate height values for ranges encompassing clustered groups of actors. Much of that data is likely already calculated by PhysX already, however. Is there some API, maybe a set of queries, even callbacks from the spatial system, that I could use to predict where terrain height values will be needed?

    Read the article

  • If I have true i/o false or vice versa, is it an OBOE?

    - by Protector one
    I often make the mistake of inverting my truth values in my code (e.g. in my if clauses). It gives me the same feeling as when making an OBOE (Off By One Error), even though it's technically not. Would you call it an OBOE, or better yet, is there a specific term for "off by truth value"-errors? My reasoning is that all possible values of a boolean are true and false. In other words, the possible values are contained in the array: [true, false]. If you access this array by index, you'll always be off by one… when selecting the wrong one. This becomes especially obvious when you calculate your index as: index = someInt % 2. Now I understand that this usually not the case, but in my mind, it always feels like this. Almost got it, just off by one…

    Read the article

< Previous Page | 133 134 135 136 137 138 139 140 141 142 143 144  | Next Page >