  • How to configure a tun interface on Linux for SSH port forwarding?

    - by sarshad
    I am trying to forward port 139 from a Windows machine to my Ubuntu SSH server on a tun interface with the ip address 10.0.0.1. This is so that I can access the windows shares on the machine on my Ubuntu server, through the reverse tunnel. I can forward ports to 127.0.0.1, but not to 10.0.0.1. On windows I am using the Tunnelier ssh client. On my Ubuntu server, the following message is printed in auth.log: Received disconnect from 124.109.51.154: 11: Server denied request for client-side server-2-client forwarding on 10.0.0.1:139. So far i have tried the following settings: GatewayPorts yes PermitTunnel yes AllowTcpForwarding yes in the /etc/ssh/sshd_config file, but it did not work. I set up the tun like this: sudo tunctl -t loc_0 -u myusername sudo ifconfig loc_0 inet 10.0.0.1 netmask 255.255.255.0 up The settings in the Tunneler ssh client should not matter because I can forward port 139 successfully to the Microsoft Loopback Adapter on a Windows machine running the WinSSHD server. Versions: Windows is XP SP3, Ubuntu is 10.10. Update: I tried to forward the port to a number greater than 1024 mentioning the IP address of the tun, and it successfully connected but the forwarding was done on 127.0.0.1 instead of the tun's IP address 10.0.0.1. So there are two separate problems now, when connecting from the Windows machine: 1) Forwarding on ports less than 1024 is probably being denied. How can we allow that on the server? 2) Forwarding is done only on 127.0.0.1 even if I mention 10.0.0.1 which is the tun's IP address. Another attempt: I also tried to forward port 22 of a Linux machine to the tun's port 55567. It showed success. But when I tried to ssh into that port using both local addresses, on the Linux machine in its debug display I got the error Connection failed: no route to host when using 127.0.0.1 to connect and simply Connection refused when using the tun's IP address. So the tun is not getting the forwarded port no matter we connect from a Windows client or a Linux client.

    Read the article

  • How to troubleshoot port forwarding on Windows 7 (64 Bit) with ICS enabled?

    - by LearnCocos2D
    I want to forward some ports (1666 for perforce, 8081 for Hudson) on my Internet Gateway machine. This machine is running Windows 7 (64 Bit, legal, user-account) and connected to the Internet via cable modem (it's not a router). The Windows machine is sharing its Internet Connection via ICS and that works fine on all connected computers. I can access the services via the gateway's public IP (95.x.x.x) on the given ports if they are running on the gateway machine itself. I've added the ports and destination IP address (192.168.0.18) in the Internet network adapter's Advanced Settings dialog (Sharing tab). That's the same dialog where you have a list of preconfigured services like HTTP, FTP and other incoming services. When I do that I can't connect to the services anymore. For some reason port forwarding isn't working. I have uninstalled Bitdefender because I wanted to check if the Firewall interferes. I've also disabled the Windows Firewall and Defender to no avail. I tried a freeware tool that helps to setup port forwarding but that didn't work either. The target machine is a Mac OS X computer whose Firewall is disabled. The IP is static. I can successfully connect to the services using the local IP address (192.168.0.18) from two different machines, including the gateway computer. So internally and externally it seems to me that the ports are open and not blocked, and the issue is with port forwarding itself. From what I understand it should be enough to add an entry to the Advanced Settings dialog to enable port forwarding when there are no firewalls interfering. How can I troubleshoot why port forwarding isn't working for me? What steps should I follow to alleviate the issue? PS: I gladly accept command line solutions. Other things I've tried: adding an Inbound Rule to Windows Firewall for the 1666, 8081 ports trying with Windows Firewall enabled and disabled disabling/enabling the network adapter double-checked that the IP addresses are correct mapping a different incoming port to the service's actual port followed or checked the misc tips in this article What I haven't dared trying yet (let me know if it's worth a shot): disable/enable ICS remove all network adapters (via Control Panel), then re-install and re-configure them

    Read the article

  • ASP.NET 2.0 and COM Port Communication

    - by theaviator
    ASP.NET 2.0 and COM Port Communication Hello Guys, I have a managed DLL which communicates with the devices attached on COM/Serial ports. The desktop Winforms application sends requests on ports and receives/stores data in memory. In Winforms app I have added a reference to DLL and I am using the methods. This works well. Now, there is a situation where I need to show this data from serial/com port on a web-page. And also users should be able to send requests to the ports using this DLL. I have made a web app in ASP.NET (2.0). Added a reference to the DLL. I am able to use this DLL, the DLL communicates on the COM upon button click on web-page and also the response is shown on web page. However I am not happy with the approach and strongly feel that this is a bad approach. Also the development server crashes after 3 -4 requests. What is the best approach in this scenario. If I use a windows service then how would my ASP.net app will communicate with the Weindows service. Or can this be easily done using WCF. I have not used WCF any time nor any of .net remoting technique. Please suggest me the best architecture in this scenario. Thank you

    Read the article

  • grep 5 seconds of input from the serial port inside a shell-script

    - by pica
    I've got a device that I'm operating next to my PC and as it runs it's spitting log lines out it's serial port. I have this wired to my PC and I can see the log lines fine if I'm using either minicom or something like: ttylog -b 115200 -d /dev/ttyS0 I want to write 5 seconds of the device serial output to a temp file (or assign it to a variable) and then later grep that file for keywords that will let me know how the device is operating. I've already tried redirecting the output to a file while running the command in the background, and then sleeping 5 seconds and killing the process, but the log lines never get written to my temp file. Example: touch tempFile ttylog -b 115200 -d /dev/ttyS0 >> tempFile & serialPID=$! sleep 5 #kill ${serialPID} #does not work, gets wrong PID killall ttylog cat tempFile The file gets created but never filled with any data. I can also replace the ttylog line with: ttylog -b 115200 -d /dev/ttyS0 |tee -a tempFile & In neither case do I ever see any log lines logged to stdout or the log file unless I have multiple versions of ttylog running by mistake (see commented out line, D'oh). I have no idea what's going on here. It seems to be a failure of redirection within my script. Am I on the right track? Is there a better way to sample 5 seconds of the serial port?

    Read the article

  • Port Java Application to Android

    - by mihirk
    I am not so sure about the question or what I should call what I am trying to achieve. I use a dialer called super sify. Here is the download - http://thegoan.com/supersify/supersify.zip The when extracted it has two files for linux, one is a .jar file which consists of some classes. The application was written in java. The other is a .sh file, which is a shell executable and takes some parameters like username and password and machine id and stuff. I want to port this app to android. What exactly would I have to do. Some more information is the .jar file is named supersify.jar and the .sh file is named ss.sh so here is the code for ss.sh java -jar supersify.jar $* if [ $? -eq 1 ] then read fi Please help me out. This is an open source software.So I am not doing any illegal modifications. I need to port this app to android, so would I have to write the whole thing again or just something else. I know some basic hello world android app development, and I have made an app to add two numbers, I am still on my way to become an android app developer, but I need this app and will learn a lot to make this possible unless it involves rewriting all the java classes. Thank you in advance If you have anymore question I will be glad to answer to them :D.

    Read the article

  • Python Access Parallel Port

    - by PPTim
    Hi, I've been trying to access the parallel port with pyParallel, which is in the same sourceforge as PySerial: http://sourceforge.net/projects/pyserial/files/ I'm getting a WidowsError: exception: priviledged instruciton. Has anyone used this module before? import parallel p = parallel.Parallel() Traceback (most recent call last): File "<interactive input>", line 1, in <module> File "C:\Python26\lib\site-packages\parallel\parallelwin32.py", line 74, in __init__ self.ctrlReg = _pyparallel.inp(self.ctrlRegAdr) WindowsError: exception: priviledged instruction

    Read the article

  • Monitor serial port already open

    - by Cristiano
    Hi, I am try to read data over serial port already open. I have used C# and c++ library for use microsoft api (overlapped and not overlapped I/O), but not work. I can use same windows api? or other?? Thanks in advance for your availability, Cristiano http://bugbusters.altervista.org/index.php

    Read the article

  • running a parallel port controlling program through php.

    - by prateek
    I have a program that is interacting with hardware via parallel port programming. i had compiled it and using its object file to interact with the hardware (a simple led). when i execute it directly on the shell it serves the purpose of glowing the LED but when i execute it using shell_exec() in php the command is executed but unable to interact with the hardware. i am totally confused.. .

    Read the article

  • Un-enlisting a BizTalk MSMQ send port in batch file

    - by SteveC
    I've got a solution which I setup / cleanup using batch files ... - there are a pair of MSMQ ports, send and receive, with another application on the end of the queues I'm finding I can't properly stop the orchestration in the batch file ... the error is the send port is unenlisted - I'm using the StopOrch.vbs script from the SDK samples But I can go into BizTalk Admin Console and manually stop the orchestration with Full Terminate Ok The setup / cleanup works Ok if I don't actually push any messages down the MSMQ queues

    Read the article

  • WCF port routing

    - by C james
    I have NAT which received incoming WCF requests and changes port number before it hands off to the host however, this is causing problem is there anyway to turn this off or fix? ex) wcf.service.com:80 - NAT - wcf.service.2522 !error Thank you.

    Read the article

  • Reopening serial port fails if not closed properly with CloseHandle

    - by superg
    I am working with USB device on Windows that is seen as a virtual serial port. I can communicate with the device using CreateFile and ReadFile functions, but in some cases my application does not call CloseHandle (when my application in development crashes). After that all calls to CreateFile fail (ERROR_ACCESS_DENIED), and the only solution is to log in to my computer again. Is there any way to force closing the open handle (or reopening) programmatically?

    Read the article

  • BizTalk 2009 - The Community ODBC Adapter: Send Port

    - by Stuart Brierley
    I have previously talked about the installation of the Community ODBC adapter and also using the ODBC adapter to generate schemas and laterly the creation of a receive port using the ODBC Adapter.  But what about creating a send port? Select to add a new Send Port, select the ODBC Adapter and click configure. Clicking Connection string will open the DataSource window. Choose one of your system datasources and press OK. This will now update the Transport properties.  Select okay. All that remains is to set the standard send port properties and your ODBC send port is now ready.

    Read the article

  • How to change Port 27000 from filtered to open status

    - by Nadarajah Ranjan
    In my ubuntu box I am running flexlm licensing software on port 27000 and I am able to pull the license from the this port to run the simulation software locally. I am also trying to run the same software in another Linux machine (opensuse) by using the flexlm license from the Ubuntu box. However, my opensuse box is unable to communicate with port 27000 in my Ubuntu box. I have turned off the firewall on the Ubuntu box, played around with iptables and when I do a nmap from my opensuse box to Ubuntu box the message I get is that port 27000 is on filtered status. My understanding is that filtered status does not allow the opensuse box to communicate with Ubuntu. My question is how to change port 27000 from filtered status to open status? Hope someone can help me out. Thank you.

    Read the article

  • Setting Default Ubuntu eth port

    - by No1_Melman
    Background: I have a desktop computer running Ubuntu 12.04. I have installed DRBL to handle DHCP server and Clonezilla Server. I have a network card in my desktop with 2 ports in it. These 2 ports are bonded together and are used by DRBL. There is a 3rd port integrated in the motherboard. I want to use this 3rd port for internet. DRBL knows that this is set for internet. Ubuntu Network-Manager has stopped recognising the connections (device not managed). It use to say that eth1 was default (first port in the network card) I want eth0 to be default as that is the Internet port. Question: How do I make network-manager see eth0 as the defualt port?

    Read the article

  • Adjust parameters of serial port reading

    - by clinisbut
    Hello. I'm facing a particular issue that regards serial communication under win32. I'm communicating with a device can only accept frames when it is not already communicating. So I must find a valid frame and then inmediatelly send my request. I developed a class named Serial that handles basic operations on serial port (open, close, read, write) and then a Thread calls inside a loop read and write functions. Thread loop //Device is an object of class Serial while( device->isOpen() && !terminate ) { unsigned int readed = 0; unsigned long error = ERROR_SUCCESS; unsigned char* data = device->read( &readed, &error ); if( error==ERROR_SUCCESS ) { //If data received, deliver to upper level if( readed>0 ) { QByteArray output( (const char*)data, (signed int)readed ); emit dataArrived( output, readed ); } } else { //unrelated stuff } //Here I manage the writting issue //Only when nothing is received, and Upper layer wants to send a frame //(Upper layer only will mark as something to send when it detects a valid frame) if( readed==0 ) { out_lock.lock(); //If something to send... if( something_to_send > 0 ) { if( device->write( output_buffer, output_size, &error ) ) { //things... } } } } The Thread basically keeps reading, and when nothing is received, sees if somebody has signaled to send a frame (this means that a valid frame is just received). When this happens, it writes the frame through serial port. Here comes my problem. Inside the Serial::read() function: I use the overlapped way of reading: ::ClearCommError( handle, &dwErrors, &stat); if( stat.cbInQue ) { //If there's something to read, read it, please note the bytes to read parameter, here 1. bool ok = ::ReadFile( handle, buffer_in, 1, &bytes_read, &ov_reader ); if( !ok ) { DWORD _error = ::GetLastError(); if( _error == ERROR_IO_PENDING ) { DWORD result = ::WaitForMultipleObjects( 2, waiters, FALSE,INFINITE ); switch( result ) { //Eventshutdown case WAIT_OBJECT_0: /*code omitted*/break; case WAIT_OBJECT_0+1: ok = ::GetOverlappedResult( handle, &ov_reader, &bytes_read, true ); //check ok value omitted break; } } } } if( bytes_read>0 ) { *size = bytes_read; } Here starts my problem. When device sends me small frames (around 30 bytes) everything works fine, but when larger frames are sent, the code is not able to find any free time between frames causing the thread to never be able send any frame because readed is never 0. If I increase the number of bytes to read inside the read() function, lose the ability to detect when the device "listens": bool ok = ::ReadFile(handle, buffer_in, 50, &bytes_read, &ov_reader ); This happens because my app can receive the end of a frame together with the start of the next one. This behaviour is very common. In the other hand, if I change the INFINITE argument by a valid timeout in the WaitForMultipleObjects function, I lose data. So my question basically is... what I'm doing wrong? Why when reading 1 byte each time I don't find any free time to send my own frames? Thank you

    Read the article

  • Windows SBS 2008 - how to diagnose port forwarding problems?

    - by Alt_Doru
    We have a Windows SBS 2008 machine. Several ports need to be forwarded from the router to the server (the machine hosts a FTP server, a Web server, and we need to be access it through Remote Desktop). We recently changed routers (from SpeedTouch to Huawei EchoLife HG520s). With the previous router, port forwarding worked fine. Now, after setting up port forwarding on the new router, nothing works anymore. Can anybody help me with directions on how to diagnose/troubleshoot port forwarding problems on the router and in Windows SBS 2008? E.G.: after forwarding a port in the router interface to the internal IP of the server, how can I see in the SBS 2008 logs if the request is properly forwarded to it?

    Read the article

  • Why does Django's dev server use port 8000 by default?

    - by kojiro
    (My question isn't really about Django. It's about alternative http ports. I just happen to know Django is a relatively famous application that uses 8000 by default, so it's illustrative.) I have a dev server in the wild that we occasionally need to run multiple httpd services on on different ports. When I needed to stand a third service up and we were already using ports 80 and 8080, I discovered our security team has locked port 8000 access from the Internet. I recognize that port 80 is the standard http port, and 8080 is commonly http_alt, but I'd like to make the case to our security team to open 8000 as well. In order to make that case, I hope the answer to this question can provide me with a reasonable argument for using port 8000 over 8080 in some case. Or was it just a random choice with no meaning?

    Read the article

  • How can I login to Ubuntu using a USB serial port?

    - by marc
    How can enable remote terminal login into Ubuntu 9.10 using a USB serial port? I created device /dev/ttyUSB0 and i want to allow logins using Hyper-Terminal. I found some resources but they are related to real hardware rs232 ports. I can't find any information about USB converter. So far I have established connection between that USB-serial port and my laptop. I can send text to the port (cp sometext.txt /dev/ttyUSB0) and read it using hyperterminal. What do I need to do to enable logins on this port?

    Read the article

  • Reading Binary data from a Serial Port.

    - by rross
    I previously have been reading NMEA data from a GPS via a serial port using C#. Now I'm doing something similar, but instead of GPS from a serial. I'm attempting to read a KISS Statement from a TNC. I'm using this event handler. comport.DataReceived += new SerialDataReceivedEventHandler(port_DataReceived); Here is port_DataReceived. private void port_DataReceived(object sender, SerialDataReceivedEventArgs e) { string data = comport.ReadExisting(); sBuffer = data; try { this.Invoke(new EventHandler(delegate { ProcessBuffer(sBuffer); })); } catch { } } The problem I'm having is that the method is being called several times per statement. So the ProcessBuffer method is being called with only a partial statment. How can I read the whole statement?

    Read the article