Search Results

Search found 22668 results on 907 pages for 'command prompt'.

Page 200/907 | < Previous Page | 196 197 198 199 200 201 202 203 204 205 206 207  | Next Page >

  • How To Delete Built-in Windows 7 Power Plans (and Why You Probably Shouldn’t)

    - by The Geek
    Do you actually use the Windows 7 power management features? If so, have you ever wanted to just delete one of the built-in power plans? Here’s how you can do so, and why you probably should leave it alone. Just in case you’re new to the party, we’re talking about the power plans that you see when you click on the battery/plug icon in the system tray. The problem is that one of the built-in plans always shows up there, even if you only use custom plans. When you go to “More power options” on the menu there, you’ll be taken to a list of them, but you’ll be unable to get rid of any of the built-in ones, even if you have your own. You can actually delete the power plans, but it will probably cause problems, so we highly recommend against it. If you still want to proceed, keep reading. Delete Built-in Power Plans in Windows 7 Open up an Administrator mod command prompt by right-clicking on the command prompt and choosing “Run as Administrator”, then type in the following command, which will show you a whole list of the plans. powercfg list Do you see that really long GUID code in the middle of each listing? That’s what we’re going to need for the next step. To make it easier, we’ll provide the codes here, just in case you don’t know how to copy to the clipboard from the command prompt. Power Scheme GUID: 381b4222-f694-41f0-9685-ff5bb260df2e  (Balanced) Power Scheme GUID: 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c  (High performance)Power Scheme GUID: a1841308-3541-4fab-bc81-f71556f20b4a  (Power saver) Before you do any deleting, what you’re going to want to do is export the plan to a file using the –export parameter. For some unknown reason, I used the .xml extension when I did this, though the file isn’t in XML format. Moving on… here’s the syntax of the command: powercfg –export balanced.xml 381b4222-f694-41f0-9685-ff5bb260df2e This will export the Balanced plan to the file balanced.xml. And now, we can delete the plan by using the –delete parameter, and the same GUID.  powercfg –delete 381b4222-f694-41f0-9685-ff5bb260df2e If you want to import the plan again, you can use the -import parameter, though it has one weirdness—you have to specify the full path to the file, like this: powercfg –import c:\balanced.xml Using what you’ve learned, you can export each of the plans to a file, and then delete the ones you want to delete. Why Shouldn’t You Do This? Very simple. Stuff will break. On my test machine, for example, I removed all of the built-in plans, and then imported them all back in, but I’m still getting this error anytime I try to access the panel to choose what the power buttons do: There’s a lot more error messages, but I’m not going to waste your time with all of them. So if you want to delete the plans, do so at your own peril. At least you’ve been warned! Similar Articles Productive Geek Tips Learning Windows 7: Manage Power SettingsCreate a Shortcut or Hotkey to Switch Power PlansDisable Power Management on Windows 7 or VistaChange the Windows 7 or Vista Power Buttons to Shut Down/Sleep/HibernateDisable Windows Vista’s Built-in CD/DVD Burning Features TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Gadfly is a cool Twitter/Silverlight app Enable DreamScene in Windows 7 Microsoft’s “How Do I ?” Videos Home Networks – How do they look like & the problems they cause Check Your IMAP Mail Offline In Thunderbird Follow Finder Finds You Twitter Users To Follow

    Read the article

  • Determining Maximum Txpower a WiFi Card Supports?

    - by BigGenius
    I have a Atheros R9285 wifi card. How can i determine , what is max. Txpower it can support? biggenius@hackbook:~$ iwconfig lo no wireless extensions. wlan0 IEEE 802.11abgn ESSID:"Default" Mode:Managed Frequency:2.437 GHz Access Point: 00:08:5C:9D:4F:40 Bit Rate=2 Mb/s Tx-Power=35 dBm Retry long limit:7 RTS thr:off Fragment thr:off Power Management:on Link Quality=24/70 Signal level=-86 dBm Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:140 Invalid misc:247 Missed beacon:0 eth0 no wireless extensions. biggenius@hackbook:~$ iw phy0 info Wiphy phy0 Band 1: Capabilities: 0x11ce HT20/HT40 SM Power Save disabled RX HT40 SGI TX STBC RX STBC 1-stream Max AMSDU length: 3839 bytes DSSS/CCK HT40 Maximum RX AMPDU length 65535 bytes (exponent: 0x003) Minimum RX AMPDU time spacing: 8 usec (0x06) HT TX/RX MCS rate indexes supported: 0-7 Frequencies: * 2412 MHz [1] (35.0 dBm) * 2417 MHz [2] (35.0 dBm) * 2422 MHz [3] (35.0 dBm) * 2427 MHz [4] (35.0 dBm) * 2432 MHz [5] (35.0 dBm) * 2437 MHz [6] (35.0 dBm) * 2442 MHz [7] (35.0 dBm) * 2447 MHz [8] (35.0 dBm) * 2452 MHz [9] (35.0 dBm) * 2457 MHz [10] (35.0 dBm) * 2462 MHz [11] (35.0 dBm) * 2467 MHz [12] (35.0 dBm) * 2472 MHz [13] (35.0 dBm) * 2484 MHz [14] (35.0 dBm) Bitrates (non-HT): * 1.0 Mbps * 2.0 Mbps (short preamble supported) * 5.5 Mbps (short preamble supported) * 11.0 Mbps (short preamble supported) * 6.0 Mbps * 9.0 Mbps * 12.0 Mbps * 18.0 Mbps * 24.0 Mbps * 36.0 Mbps * 48.0 Mbps * 54.0 Mbps Band 2: Capabilities: 0x11ce HT20/HT40 SM Power Save disabled RX HT40 SGI TX STBC RX STBC 1-stream Max AMSDU length: 3839 bytes DSSS/CCK HT40 Maximum RX AMPDU length 65535 bytes (exponent: 0x003) Minimum RX AMPDU time spacing: 8 usec (0x06) HT TX/RX MCS rate indexes supported: 0-7 Frequencies: * 5180 MHz [36] (35.0 dBm) * 5200 MHz [40] (35.0 dBm) * 5220 MHz [44] (35.0 dBm) * 5240 MHz [48] (35.0 dBm) * 5260 MHz [52] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5280 MHz [56] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5300 MHz [60] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5320 MHz [64] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5500 MHz [100] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5520 MHz [104] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5540 MHz [108] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5560 MHz [112] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5580 MHz [116] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5600 MHz [120] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5620 MHz [124] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5640 MHz [128] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5660 MHz [132] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5680 MHz [136] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5700 MHz [140] (35.0 dBm) (passive scanning, no IBSS, radar detection) * 5745 MHz [149] (35.0 dBm) * 5765 MHz [153] (35.0 dBm) * 5785 MHz [157] (35.0 dBm) * 5805 MHz [161] (35.0 dBm) * 5825 MHz [165] (35.0 dBm) Bitrates (non-HT): * 6.0 Mbps * 9.0 Mbps * 12.0 Mbps * 18.0 Mbps * 24.0 Mbps * 36.0 Mbps * 48.0 Mbps * 54.0 Mbps max # scan SSIDs: 4 max scan IEs length: 2257 bytes Coverage class: 0 (up to 0m) Supported Ciphers: * WEP40 (00-0f-ac:1) * WEP104 (00-0f-ac:5) * TKIP (00-0f-ac:2) * CCMP (00-0f-ac:4) * CMAC (00-0f-ac:6) Available Antennas: TX 0x1 RX 0x3 Configured Antennas: TX 0x1 RX 0x3 Supported interface modes: * IBSS * managed * AP * AP/VLAN * WDS * monitor * mesh point * P2P-client * P2P-GO software interface modes (can always be added): * AP/VLAN * monitor valid interface combinations: * #{ managed, WDS, P2P-client } <= 2048, #{ AP, mesh point, P2P-GO } <= 8, total <= 2048, #channels <= 1 Supported commands: * new_interface * set_interface * new_key * new_beacon * new_station * new_mpath * set_mesh_params * set_bss * authenticate * associate * deauthenticate * disassociate * join_ibss * join_mesh * remain_on_channel * set_tx_bitrate_mask * action * frame_wait_cancel * set_wiphy_netns * set_channel * set_wds_peer * Unknown command (82) * Unknown command (81) * Unknown command (84) * Unknown command (87) * Unknown command (85) * testmode * connect * disconnect Supported TX frame types: * IBSS: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * managed: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * AP: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * AP/VLAN: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * mesh point: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * P2P-client: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * P2P-GO: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 Supported RX frame types: * IBSS: 0x00d0 * managed: 0x0040 0x00d0 * AP: 0x0000 0x0020 0x0040 0x00a0 0x00b0 0x00c0 0x00d0 * AP/VLAN: 0x0000 0x0020 0x0040 0x00a0 0x00b0 0x00c0 0x00d0 * mesh point: 0x00b0 0x00c0 0x00d0 * P2P-client: 0x0040 0x00d0 * P2P-GO: 0x0000 0x0020 0x0040 0x00a0 0x00b0 0x00c0 0x00d0 Device supports RSN-IBSS.

    Read the article

  • FTP Upload ftpWebRequest Proxy

    - by Rodney Vinyard
    Searchable:   FTP Upload ftpWebRequest Proxy FTP command is not supported when using HTTP proxy     In the article below I will cover 2 topics   1.       C# & Windows Command-Line FTP Upload with No Proxy Server   2.       C# & Windows Command-Line FTP Upload with Proxy Server   Not covered here: Secure FTP / SFTP   Sample Attributes: ·         UploadFilePath = “\\servername\folder\file.name” ·         Proxy Server = “ftp://proxy.server/” ·         FTP Target Server = ftp.target.com ·         FTP User = “User” ·         FTP Password = “Password” with No Proxy Server ·         Windows Command-Line > ftp ftp.target.com > ftp User: User > ftp Password: Password > ftp put \\servername\folder\file.name > ftp dir           (result: file.name listed) > ftp del file.name > ftp dir           (result: file.name deleted) > ftp quit   ·         C#   //----------------- //Start FTP via _TargetFtpProxy //----------------- string relPath = Path.GetFileName(\\servername\folder\file.name);   //result: relPath = “file.name”   FtpWebRequest ftpWebRequest = (FtpWebRequest)WebRequest.Create("ftp.target.com/file.name); ftpWebRequest.Method = WebRequestMethods.Ftp.UploadFile;   //----------------- //user - password //----------------- ftpWebRequest.Credentials = new NetworkCredential("user, "password");   //----------------- // set proxy = null! //----------------- ftpWebRequest.Proxy = null;   //----------------- // Copy the contents of the file to the request stream. //----------------- StreamReader sourceStream = new StreamReader(“\\servername\folder\file.name”);   byte[] fileContents = Encoding.UTF8.GetBytes(sourceStream.ReadToEnd()); sourceStream.Close(); ftpWebRequest.ContentLength = fileContents.Length;     //----------------- // transer the stream stream. //----------------- Stream requestStream = ftpWebRequest.GetRequestStream(); requestStream.Write(fileContents, 0, fileContents.Length); requestStream.Close();   //----------------- // Look at the response results //----------------- FtpWebResponse response = (FtpWebResponse)ftpWebRequest.GetResponse();   Console.WriteLine("Upload File Complete, status {0}", response.StatusDescription);   with Proxy Server ·         Windows Command-Line > ftp proxy.server > ftp User: [email protected] > ftp Password: Password > ftp put \\servername\folder\file.name > ftp dir           (result: file.name listed) > ftp del file.name > ftp dir           (result: file.name deleted) > ftp quit   ·         C#   //----------------- //Start FTP via _TargetFtpProxy //----------------- string relPath = Path.GetFileName(\\servername\folder\file.name);   //result: relPath = “file.name”   FtpWebRequest ftpWebRequest = (FtpWebRequest)WebRequest.Create("ftp://proxy.server/" + relPath); ftpWebRequest.Method = WebRequestMethods.Ftp.UploadFile;   //----------------- //user - password //----------------- ftpWebRequest.Credentials = new NetworkCredential("[email protected], "password");   //----------------- // set proxy = null! //----------------- ftpWebRequest.Proxy = null;   //----------------- // Copy the contents of the file to the request stream. //----------------- StreamReader sourceStream = new StreamReader(“\\servername\folder\file.name”);   byte[] fileContents = Encoding.UTF8.GetBytes(sourceStream.ReadToEnd()); sourceStream.Close(); ftpWebRequest.ContentLength = fileContents.Length;     //----------------- // transer the stream stream. //----------------- Stream requestStream = ftpWebRequest.GetRequestStream(); requestStream.Write(fileContents, 0, fileContents.Length); requestStream.Close();   //----------------- // Look at the response results //----------------- FtpWebResponse response = (FtpWebResponse)ftpWebRequest.GetResponse();   Console.WriteLine("Upload File Complete, status {0}", response.StatusDescription);

    Read the article

  • Developer Preview available for the Java Access Bridge is now included in Java SE 7 Update 6

    - by Ragini Prasad
    The Java Access Bridge product is now being included with Java SE 7u6. Manual installation of the Java Access Bridge will no longer be required. All Access Bridge files will be automatically installed by the JRE and the JDK.             The Developer Preview for this feature is now available and can be downloaded from http://jdk7.java.net/download.html.            By default, the Java Access Bridge is disabled. In order to use the Java Access Bridge, enable it using the steps mentioned below and test your applications for accessibility.             Enable the Java Access Bridge: Use one of these mechanism:             1. Ease Of Access control panel.     On Windows Vista and later the Java Access Bridge can be enabled     from Ease of Access Center.     Select "Use the computer without a display". In "Other programs     installed" section , select the check box to     "Enable Java Access Bridge" and apply. 2. Or run the following command in the Command Window.     %JRE_HOME%\bin\jabswitch -enable Note: You must restart your Assistive Technology software and Java application after enabling the bridge.             Test the Java Access Bridge: 1. Enable the Java Access Bridge as described above. 2. Run an Assistive Technology that supports the Java Access Bridge. 3. Run a Java application. Ensure that the Assistive Technology  reads    the values of your application. Disable the Java Access Bridge:             Run the following command from the Command Window.     %JRE_HOME%\bin\jabswitch -disable                 Note: The Ease Of Access control panel cannot be used to disable the bridge. You must use jabswitch from the Command window to disable the Java Access Bridge.

    Read the article

  • Resolve SRs Faster Using RDA - Find the Right Profile

    - by Daniel Mortimer
    Introduction Remote Diagnostic Agent (RDA) is an excellent command-line data collection tool that can aid troubleshooting / problem solving. The tool covers the majority of Oracle's vast product range, and its data collection capability is comprehensive. RDA collects data about the operating system and environment, including environment variable, kernel settings network o/s performance o/s patches and much more the Oracle Products installed, including patches logs and debug metrics configuration and much more In effect, RDA can obtain a snapshot of an Oracle Product and its environment. Oracle Support encourages the use of RDA because it greatly reduces service request resolution time by minimizing the number of requests from Oracle Support for more information. RDA is designed to be as unobtrusive as possible; it does not modify systems in any way. It collects useful data for Oracle Support only and a security filter is provided if required. Find and Use the Right RDA Profile One problem of any tool / utility, which covers a large range of products, is knowing how to target it against only the products you wish to troubleshoot. RDA does not have a GUI. Nor does RDA have an intelligent mechanism for detecting and automatically collecting data only for those Oracle products installed. Instead, you have to tell RDA what to do. There is a mind boggling large number of RDA data collection modules which you can configure RDA to use. It is easier, however, to setup RDA to use a "Profile". A profile consists of a list of data collection modules and predefined settings. As such profiles can be used to diagnose a problem with a particular product or combination of products. How to run RDA with a profile? ( <rda> represents the command you selected to run RDA (for example, rda.pl, rda.cmd, rda.sh, and perl rda.pl).) 1. Use the embedded spreadsheet to find the RDA profile which is appropriate for your problem / chosen Oracle Fusion Middleware products. 2. Use the following command to perform the setup <rda> -S -p <profile_name>  3. Run the data collection <rda> Run the data collection. If you want to perform setup and run in one go, then use a command such as the following: <rda> -vnSCRP -p <profile name> For more information, refer to: Remote Diagnostic Agent (RDA) 4 - Profile Manual Pages [ID 391983.1] Additional Hints / Tips: 1. Be careful! Profile names are case sensitive.2. When profiles are not used, RDA considers all existing modules by default. For example, if you have downloaded RDA for the first time and run the command <rda> -S you will see prompts for every RDA collection module many of which will be of no interest to you. Also, you may, in your haste to work through all the questions, forget to say "Yes" to the collection of data that is pertinent to your particular problem or product. Profiles avoid such tedium and help ensure the right data is collected at the first time of asking.

    Read the article

  • How to undo a changeset using tf.exe rollback

    - by Tarun Arora
    Technorati Tags: Team Foundation Server 2010,Team Foundation Utilities,TFS2010   Oh no! Did you just check in a changeset in to TFS and realized that you need to roll back the changeset because the changes were suppose to go in a different branch? Or did you just accidently merge a wrong changeset in your release branch? There are several ways to undo the damage, Manual: Yes, we all just hate this word but for the record you could manually rollback the changes. Get Specific version on the branch and chose the changeset prior to the one you checked in. After that check out all the files in the changeset and check them in. During the check in you will receive a conflict. At this point choose ‘Keep local changes’ in the conflict resolution window and check in the files. Automated: Yes, we just love it! TFS comes with a very powerful command line utility ‘tf.exe’ that gives you the ability to rollback the effects of one or more changesets to one or more version-controlled items. This command does not remove the changesets from an item's version history. Instead, this command creates in your workspace a set of pending changes that negate the effects of the changesets that you specify. Syntax tf rollback /toversion:VersionSpec ItemSpec [/recursive] [/lock:none|checkin|checkout] [/version:versionspec] [/keepmergehistory] [/login:username,[password]] [/noprompt] tf rollback /changeset:ChangesetFrom~ChangesetTo [ItemSpec] [/recursive] [/lock:none|checkin|checkout] [/version:VersionSpec] [/keepmergehistory] [/noprompt] [/login:username,[password]]   I’ll explain this with an example. Your workspace is at the location C:\myWorkspace You want to rollback changeset # 145621 C:\Workspace\MyBranch>tf.exe rollback /changeset:145621 /recursive How do i rollback/undo a series of changesets? You can also rollback a range of changesets by using the following C:\Workspace\MyBranch>tf.exe rollback /changeset:145601~145621 /recursive This will check out the files in the version control and you should be able to see them in the pending changes. Go on check them in to undo the specific changeset that you just rolled back. Do you completely want to get rid of the changeset from all future merges between the two branches? /KeepMergeHistory: This option has an effect only if one or more of the changesets that you are rolling back include a branch or merge change. Specify this option if you want future merges between the same source and the same target to exclude the changes that you are rolling back. Errors “If you get the message ‘Unable to determine the workspace.’ You may be able to correct this by running ‘tf worksapces /collection:TeamProjectCollectionUrl’” you are in the wrong directory. Make sure that you run the ‘tf rollback’ command from the directory of your workspace.   Status Exit Code Description 0 The operation rolled back all items successfully. 1 The operation rolled back at least one item successfully but could not roll back one or more items. 100 The operation could not roll back any items.   To use the command you must have the Read, Check Out, and Check In permissions set to Allow. So, have you been in a rollback undo situation before?   Share this post :

    Read the article

  • Communication between state machines with hidden transitions

    - by slartibartfast
    The question emerged for me in embedded programming but I think it can be applied to quite a number of general networking situations e.g. when a communication partner fails. Assume we have an application logic (a program) running on a computer and a gadget connected to that computer via e.g. a serial interface like RS232. The gadget has a red/green/blue LED and a button which disables the LED. The LEDs color can be driven by software commands over the serial interface and the state (red/green/blue/off) is read back and causes a reaction in the application logic. Asynchronous behaviour of the application logic with regard to the LED color down to a certain delay (depending on the execution cycle of the application) is tolerated. What we essentially have is a resource (the LED) which can not be reserved and handled atomically by software because the (organic) user can at any time press the button to interfere/break the software attempt to switch the LED color. Stripping this example from its physical outfit I dare to say that we have two communicating state machines A (application logic) and G (gadget) where G executes state changes unbeknownst to A (and also the other way round, but this is not significant in our example) and only A can be modified at a reasonable price. A needs to see the reaction and state of G in one piece of information which may be (slightly) outdated but not inconsistent with respect to the short time window when this information was generated on the side of G. What I am looking for is a concise method to handle such a situation in embedded software (i.e. no layer/framework like CORBA etc. available). A programming technique which is able to map the complete behaviour of both participants on classical interfaces of a classical programming language (C in this case). To complicate matters (or rather, to generalize), a simple high frequency communication cycle of A to G and back (IOW: A is rapidly polling G) is out of focus because of technical restrictions (delay of serial com, A not always active, etc.). What I currently see as a general solution is: the application logic A as one thread of execution an adapter object (proxy) PG (presenting G inside the computer), together with the serial driver as another thread a communication object between the two (A and PG) which is transactionally safe to exchange The two execution contexts (threads) on the computer may be multi-core or just interrupt driven or tasks in an RTOS. The com object contains the following data: suspected state (written by A): effectively a member of the power set of states in G (in our case: red, green, blue, off, red_or_green, red_or_blue, red_or_off...etc.) command data (written by A): test_if_off, switch_to_red, switch_to_green, switch_to_blue operation status (written by PG): operation_pending, success, wrong_state, link_broken new state (written by PG): red, green, blue, off The idea of the com object is that A writes whichever (set of) state it thinks G is in, together with a command. (Example: suspected state="red_or_green", command: "switch_to_blue") Notice that the commands issued by A will not work if the user has switched off the LED and A needs to know this. PG will pick up such a com object and try to send the command to G, receive its answer (or a timeout) and set the operation status and new state accordingly. A will take back the oject once it is no longer at operation_pending and can react to the outcome. The com object could be separated of course (into two objects, one for each direction) but I think it is convenient in nearly all instances to have the command close to the result. I would like to have major flaws pointed out or hear an entirely different view on such a situation.

    Read the article

  • Juggling with JDKs on Apple OS X

    - by Blueberry Coder
    I recently got a shiny new MacBook Pro to help me support our ADF Mobile customers. It is really a wonderful piece of hardware, although I am still adjusting to Apple's peculiar keyboard layout. Did you know, for example, that the « delete » key actually performs a « backspace »? But I disgress... As you may know, ADF Mobile development still requires JDeveloper 11gR2, which in turn runs on Java 6. On the other hand, JDeveloper 12c needs JDK 7. I wanted to install both versions, and wasn't sure how to do it.   If you remember, I explained in a previous blog entry how to install JDeveloper 11gR2 on Apple's OS X. The trick was to use the /usr/libexec/java_home command in order to invoke the proper JDK. In this case, I could have done the same thing; the two JDKs can coexist without any problems, since they install in completely different locations. But I wanted more than just installing JDeveloper. I wanted to be able to select my JDK when using the command line as well. On Windows, this is easy, since I keep all my JDKs in a central location. I simply have to move to the appropriate folder or type the folder name in the command I want to execute. Problem is, on OS X, the paths to the JDKs are... let's say convoluted.  Here is the one for Java 6. /System/Library/Java/JavaVirtualMachines/1.6.0.jdk/Contents/Home The Java 7 path is not better, just different. /Library/Java/JavaVirtualMachines/jdk1.7.0_45.jdk/Contents/Home Intuitive, isn't it? Clearly, I needed something better... On OS X, the default command shell is bash. It is possible to configure the shell environment by creating a file named « .profile » in a user's home folder. Thus, I created such a file and put the following inside: export JAVA_7_HOME=$(/usr/libexec/java_home -v1.7) export JAVA_6_HOME=$(/usr/libexec/java_home -v1.6) export JAVA_HOME=$JAVA_7_HOME alias java6='export JAVA_HOME=$JAVA_6_HOME' alias java7='export JAVA_HOME=$JAVA_7_HOME'  The first two lines retrieve the current paths for Java 7 and Java 6 and store them in two environment variables. The third line marks Java 7 as the default. The last two lines create command aliases. Thus, when I type java6, the value for JAVA_HOME is set to JAVA_6_HOME, for example.  I now have an environment which works even better than the one I have on Windows, since I can change my active JDK on a whim. Here a sample, fresh from my terminal window. fdesbien-mac:~ fdesbien$ java6 fdesbien-mac:~ fdesbien$ java -version java version "1.6.0_65" Java(TM) SE Runtime Environment (build 1.6.0_65-b14-462-11M4609) Java HotSpot(TM) 64-Bit Server VM (build 20.65-b04-462, mixed mode) fdesbien-mac:~ fdesbien$ fdesbien-mac:~ fdesbien$ java7 fdesbien-mac:~ fdesbien$ java -version java version "1.7.0_45" Java(TM) SE Runtime Environment (build 1.7.0_45-b18) Java HotSpot(TM) 64-Bit Server VM (build 24.45-b08, mixed mode) fdesbien-mac:~ fdesbien$ Et voilà! Maximum flexibility without downsides, just I like it. 

    Read the article

  • ASP.NET MVC returning ContentResult using Ajax form - how to preserve whitespace?

    - by Ben
    In my application users can enter commands that are executed on the server. The results are added to a session object. I then stuff the session object into ViewData and add it to a textarea. When done with a standard HTML form whitespace is preserved. However, when I swap this out for an ajax form (Ajax.BeginForm) and return the result as ContentResult, the whitespace is removed. Controller Action: [HttpPost] public ActionResult Execute(string submitButton, string command) { if (submitButton == "Clear") { this.CurrentConsole = string.Empty; } if (submitButton == "Execute" && !string.IsNullOrEmpty(command)) { var script = new PSScript() { Name = "Ad hoc script", CommandText = command }; this.CurrentConsole += _scriptService.ExecuteScript(script); } if (Request.IsAjaxRequest()) { return Content(this.CurrentConsole, "text/plain"); } return RedirectToAction("Index"); } View: <fieldset> <legend>Shell</legend> <%=Html.TextArea("console", ViewData["console"].ToString(), new {@class = "console", @readonly = "readonly"})%> <% using (Ajax.BeginForm("Execute", new AjaxOptions { UpdateTargetId = "console", OnBegin = "console_begin", OnComplete = "console_complete"})) { %> <input type="text" id="command" name="command" class="commandtext" /> <input type="submit" value="Execute" class="runbutton" name="submitButton" /> <input type="submit" value="Clear" class="runbutton" name="submitButton" /> <%} %> </fieldset> How can I ensure that whitespace is preserved? When I inspect the response in FireBug it looks like the whitespace is transmitted, so can only assume it has something to do with the way in which the javascript handles the response data.

    Read the article

  • How to Assign a Static IP Address in XP, Vista, or Windows 7

    - by Mysticgeek
    When organizing your home network it’s easier to assign each computer it’s own IP address than using DHCP. Here we will take a look at doing it in XP, Vista, and Windows 7. If you have a home network with several computes and devices, it’s a good idea to assign each of them a specific address. If you use DHCP (Dynamic Host Configuration Protocol), each computer will request and be assigned an address every time it’s booted up. When you have to do troubleshooting on your network, it’s annoying going to each machine to figure out what IP they have. Using Static IPs prevents address conflicts between devices and allows you to manage them more easily. Assigning IPs to Windows is essentially the same process, but getting to where you need to be varies between each version. Windows 7 To change the computer’s IP address in Windows 7, type network and sharing into the Search box in the Start Menu and select Network and Sharing Center when it comes up.   Then when the Network and Sharing Center opens, click on Change adapter settings. Right-click on your local adapter and select Properties. In the Local Area Connection Properties window highlight Internet Protocol Version 4 (TCP/IPv4) then click the Properties button. Now select the radio button Use the following IP address and enter in the correct IP, Subnet mask, and Default gateway that corresponds with your network setup. Then enter your Preferred and Alternate DNS server addresses. Here we’re on a home network and using a simple Class C network configuration and Google DNS. Check Validate settings upon exit so Windows can find any problems with the addresses you entered. When you’re finished click OK. Now close out of the Local Area Connections Properties window. Windows 7 will run network diagnostics and verify the connection is good. Here we had no problems with it, but if you did, you could run the network troubleshooting wizard. Now you can open the command prompt and do an ipconfig  to see the network adapter settings have been successfully changed.   Windows Vista Changing your IP from DHCP to a Static address in Vista is similar to Windows 7, but getting to the correct location is a bit different. Open the Start Menu, right-click on Network, and select Properties. The Network and Sharing Center opens…click on Manage network connections. Right-click on the network adapter you want to assign an IP address and click Properties. Highlight Internet Protocol Version 4 (TCP/IPv4) then click the Properties button. Now change the IP, Subnet mask, Default Gateway, and DNS Server Addresses. When you’re finished click OK. You’ll need to close out of Local Area Connection Properties for the settings to go into effect. Open the Command Prompt and do an ipconfig to verify the changes were successful.   Windows XP In this example we’re using XP SP3 Media Center Edition and changing the IP address of the Wireless adapter. To set a Static IP in XP right-click on My Network Places and select Properties. Right-click on the adapter you want to set the IP for and select Properties. Highlight Internet Protocol (TCP/IP) and click the Properties button. Now change the IP, Subnet mask, Default Gateway, and DNS Server Addresses. When you’re finished click OK. You will need to close out of the Network Connection Properties screen before the changes go into effect.   Again you can verify the settings by doing an ipconfig in the command prompt. In case you’re not sure how to do this, click on Start then Run.   In the Run box type in cmd and click OK. Then at the prompt type in ipconfig and hit Enter. This will show the IP address for the network adapter you changed.   If you have a small office or home network, assigning each computer a specific IP address makes it a lot easier to manage and troubleshoot network connection problems. Similar Articles Productive Geek Tips Change Ubuntu Desktop from DHCP to a Static IP AddressChange Ubuntu Server from DHCP to a Static IP AddressVista Breadcrumbs for Windows XPCreate a Shortcut or Hotkey for the Safely Remove Hardware DialogCreate a Shortcut or Hotkey to Eject the CD/DVD Drive TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips HippoRemote Pro 2.2 Xobni Plus for Outlook All My Movies 5.9 CloudBerry Online Backup 1.5 for Windows Home Server Nice Websites To Watch TV Shows Online 24 Million Sites Windows Media Player Glass Icons (icons we like) How to Forecast Weather, without Gadgets Outlook Tools, one stop tweaking for any Outlook version Zoofs, find the most popular tweeted YouTube videos

    Read the article

  • "device-mapper resume ioctl failed" when run a instance

    - by user1490377
    I install ubuntu-12.04 server and openstack on two computer. When Launch an image, the instance can't run and show error state! nova-compute.log details: 2012-06-24 12:02:00 DEBUG nova.utils [req-71fdca27-5f93-438e-a4be-ddc54f698171 c737b66b2102415f817ca50b9649fd8f 5b1da4eaee3643919a230efc06473720] Unexpected error while running command. Command: sudo nova-rootwrap kpartx -a /dev/nbd15 Exit code: 1 Stdout: '' Stderr: 'device-mapper: resume ioctl failed: Invalid argument\ncreate/reload failed on nbd15p1\n' from (pid=1267) trycmd /usr/lib/python2.7/dist-packages/nova/utils.py:277 2012-06-24 12:02:00 DEBUG nova.utils [req-71fdca27-5f93-438e-a4be-ddc54f698171 c737b66b2102415f817ca50b9649fd8f 5b1da4eaee3643919a230efc06473720] Running cmd (subprocess): sudo nova-rootwrap qemu-nbd -d /dev/nbd15 from (pid=1267) execute /usr/lib/python2.7/dist-packages/nova/utils.py:219 2012-06-24 12:02:02 DEBUG nova.virt.disk.api [req-71fdca27-5f93-438e-a4be-ddc54f698171 c737b66b2102415f817ca50b9649fd8f 5b1da4eaee3643919a230efc06473720] Failed to map partitions: Unexpected error while running command. Command: sudo nova-rootwrap kpartx -a /dev/nbd15 Exit code: 1 Stdout: '' Stderr: 'device-mapper: resume ioctl failed: Invalid argument\ncreate/reload failed on nbd15p1\n' from (pid=1267) mount /usr/lib/python2.7/dist-packages/nova/virt/disk/api.py:205

    Read the article

  • WPF: Xaml, create an observable collection<object> in xaml in Dot Net 4.0

    - by Aran Mulholland
    the web site says you can in dot net 4.0 I cant seem to do it though, what assesmbly references and xmlns' do i need the following does not work xmlns:coll="clr-namespace:System.Collections.ObjectModel;assembly=mscorlib" <coll:ObservableCollection x:TypeArguments="x:Object"> <MenuItem Command="ApplicationCommands.Cut"/> <MenuItem Command="ApplicationCommands.Copy"/> <MenuItem Command="ApplicationCommands.Paste"/> </coll:ObservableCollection>

    Read the article

  • WPF: Xaml, create an observable collection<object> in xaml in .NET 4.0

    - by Aran Mulholland
    the web site says you can in .NET 4.0 I cant seem to do it though, what assesmbly references and xmlns' do i need the following does not work xmlns:coll="clr-namespace:System.Collections.ObjectModel;assembly=mscorlib" <coll:ObservableCollection x:TypeArguments="x:Object"> <MenuItem Command="ApplicationCommands.Cut"/> <MenuItem Command="ApplicationCommands.Copy"/> <MenuItem Command="ApplicationCommands.Paste"/> </coll:ObservableCollection>

    Read the article

  • Npgsql pass parameters by name to a stored function

    - by Jeff
    I'm working with code I'm converting to Pgsql working with .NET. I want to call a stored function that has several parameters, but I'd like to bind the parameters by name, like so: NpgsqlCommand command = new NpgsqlCommand("\"StoredFunction\"", _Connection) command.CommandType = CommandType.StoredProcedure; command.Parameters.Add("param2", value2); command.PArameters.Add("param1", value1); Attempts to do this so far look for a function with parameter types matching in the order in which I added the parameters to the collection, not by name. Is it possible for Npgsql to bind parameters to stored functions by name?

    Read the article

  • How to execute .sh file on Windows?

    - by sushant
    When I am trying to execute a file(name.sh) in the command line by the command ./name.sh , I am getting the error that: "." is not recognized as an internal or external command, operable or batch file please help me execute the .sh file

    Read the article

  • Label in PyQt4 GUI not updating with every loop of FOR loop

    - by user297920
    I'm having a problem, where I wish to run several command line functions from a python program using a GUI. I don't know if my problem is specific to PyQt4 or if it has to do with my bad use of python code. What I wish to do is have a label on my GUI change its text value to inform the user which command is being executed. My problem however, arises when I run several commands using a for loop. I would like the label to update itself with every loop, however, the program is not updating the GUI label with every loop, instead, it only updates itself once the entire loop is completed, and displays only the last command that was executed. I am using PyQt4 for my GUI environment. And I have established that the text variable for the label is indeed being updated with every loop, but, it is not actually showing up visually in the GUI. Is there a way for me to force the label to update itself? I have tried the update() and repaint() methods within the loop, but they don't make any difference. I would really appreciate any help. Thank you. Ronny. Here is the code I am using: # -*- coding: utf-8 -*- import sys, os from PyQt4 import QtGui, QtCore Gui = QtGui Core = QtCore # ================================================== CREATE WINDOW OBJECT CLASS class Win(Gui.QWidget): def __init__(self, parent = None): Gui.QWidget.__init__(self, parent) # --------------------------------------------------- SETUP PLAY BUTTON self.but1 = Gui.QPushButton("Run Commands",self) self.but1.setGeometry(10,10, 200, 100) # -------------------------------------------------------- SETUP LABELS self.label1 = Gui.QLabel("No Commands running", self) self.label1.move(10, 120) # ------------------------------------------------------- SETUP ACTIONS self.connect(self.but1, Core.SIGNAL("clicked()"), runCommands) # ======================================================= RUN COMMAND FUNCTION def runCommands(): for i in commands: win.label1.setText(i) # Make label display the command being run print win.label1.text() # This shows that the value is actually # changing with every loop, but its just not # being reflected in the GUI label os.system(i) # ======================================================================== MAIN # ------------------------------------------------------ THE TERMINAL COMMANDS com1 = "espeak 'senntence 1'" com2 = "espeak 'senntence 2'" com3 = "espeak 'senntence 3'" com4 = "espeak 'senntence 4'" com5 = "espeak 'senntence 5'" commands = (com1, com2, com3, com4, com5) # --------------------------------------------------- SETUP THE GUI ENVIRONMENT app = Gui.QApplication(sys.argv) win = Win() win.show() sys.exit(app.exec_())

    Read the article

  • In Eclipse RCP, how do I disable a save toolbar button according to the "dirty" property in editor

    - by paulgreg
    In my eclipse RCP 3.3 application, I would like to enable or disable a 'save' toolbar button according to current editor dirty flag. I'm trying to use the <enabledWhen tag but I can't make it work. Here's the portion of code in plugin.xml : <command commandId="org.acme.command.save" icon="icons/save.png" id="org.acme.command.save" style="push"> <enabledWhen> <instanceof value="activeEditor"/> <test property="dirty" value="true"/> </enabledWhen> </command> Do you have any idea how that is supposed to work ?

    Read the article

  • Orca: extracting files from merge module

    - by Mystagogue
    All I want is a command-line tool that can extract files from a merge module (.msm) onto disk. I looked up Orca (version 3.1), whose documentation states: Many merge module options can be specified from the command line... Extracting Files from a Merge Module Orca supports three different methods for extracting files contained in a merge module. Orca can extract the individual CAB file, extract the files into a module tree and extract the files into a source image once it has been merged into a target database... Extracting Files To extract the individual files from a merge module, use the ... -x ... option on the command line, where is the desired path to the new directory tree. The specified path is used as the root path for the extracted files. All files are extracted from the CAB file embedded in the module and placed in the specified path. The directory layout for the extracted files is based on the directory tree of the merge module. It mostly sounds like exactly what I need. But when I try it, orca simply opens up an editor (with info on the msm I specified) and then does nothing. I've tried a variety of command lines: orca -x theDirectory theModule.msm orca theModule.msm -x theDirectory ...and others. I get nowhere. The closest I've gotten was this: orca -q -x theDirectory -m theModule.msm ...but then it complains that I didn't specifiy a database to merge into. But I'm not trying to merge anything, no less into a database. I just want the files extracted. Can someone explain what I'm doing wrong with the command line options?

    Read the article

  • Good ol fashioned debugging

    - by Tim Dexter
    I have been helping out one of our new customers over the last day or two and I have even managed to get to the bottom of their problem FTW! They use BIEE and BIP and wanted to mount a BIP report in a dashboard page, so far so good, BIP does that! Just follow the instructions in the BIEE user guide. The wrinkle is that they want to enter some fixed instruction strings into the dashboard prompts to help the user. These are added as fixed values to the prompt as the default values so they appear first. Once the user makes a selection, the default strings disappear. Its a fair requirement but the BIP report chokes Now, the BIP report had been setup with the Autorun checkbox, unchecked. I expected the BIP report to wait for the Go button to be hit but it was trying to run immediately and failing. That was the first issue. You can not stop the BIP report from trying to run in a dashboard. Even if the Autorun is turned off, it seems that dashboard still makes the request to BIP to run the report. Rather than BIP refusing because its waiting for input it goes ahead anyway, I guess the mechanism does not check the autorun flag when the request is coming from the dashboard. It appears that between BIEE and BIP, they collectively ignore the autorun flag. A bug? might be, at least an enhancement request. With that in mind, how could we get BIP to not at least not fail? This fact was stumping me on the parameter error, if the autorun flag was being respected then why was BIP complaining about the parameter values it should not even be doing anything until the Go button is clicked. I now knew that the autorun flag was being ignored, it was a simple case of putting BIP into debug mode. I use the OC4J server on my laptop so debug msgs are routed through the dos box used to start the OC4J container. When I changed a value on the dashboard prompt I spotted some debug text rushing by that subsequently disappeared from the log once the operation was complete. Another bug? I needed to catch that text as it went by, using the print screen function with some software to grab multiple screens as the log appeared and then disappeared. The upshot is that when you change the dashboard prompt value, BIP validates the value against its own LOVs, if its not in the list then it throws the error. Because 'Fill this first' and 'Fill this second' ie fixed strings from the dashboard prompts, are not in the LOV lists and because the report is auto running as soon as the dashboard page is brought up, the report complains about invalid parameters. To get around this, I needed to get the strings into the LOVs. Easily done with a UNION clause: select 'Fill this first' from SH.Products Products UNION select Products."Prod Category" as "Prod Category" from SH.Products Products Now when BIP wants to validate the prompt value, the LOV query fires and finds the fixed string -> No Error. No data, but definitely no errors :0) If users do run with the fixed values, you can capture that in the template. If there is no data in the report, either the fixed values were used or the parameters selected resulted in no rows. You can capture this in the template and display something like. 'Either your parameter values resulted in no data or you have not changed the default values' Thats the upside, the downside is that if your users run the report in the BP UI they re going to see the fixed strings. You could alleviate that by having BIP display the fixed strings in top of its parameter drop boxes (just set them as the default value for the parameter.) But they will not disappear like they do in the dashboard prompts, see below. If the expected autorun behaviour worked ie wait for the Go button, then we would not have to workaround it but for now, its a pretty good solution. It was an enjoyable hour or so for me, took me back to my developer daze, when we used to race each other for the most number of bug fixes. I used to run a distant 2nd behind 'Bugmeister Chen Hu' but led the chasing pack by a reasonable distance.

    Read the article

  • Using fink to install PyODE

    - by None
    I installed fink and ran this command from terminal: sudo apt-get install python-pyode. I found this command on the internet and expected it to work, as I just installed fink. Am I using the wrong name? Is there a different command to use for Mac OS X (10.5)?

    Read the article

  • Anyone have BlazeDS working with WebLogic Security (j_security_check) ??

    - by Brian
    I'm working on a Flex implementation (currently using SDK 3.5) on WebLogic 10.3 (11G.) We originally used Glassfish v2.1.1 with zero issues (there was an active directory group lookup bug but it did not hinder our progress.) Since transitioning to WebLogic we have an issue where the flexsession is invalidated after logging in using j_security_check: [BlazeDS]Unexpected error encountered in Message Broker servlet flex.messaging.LocalizedException: The FlexSession is invalid. at flex.messaging.FlexSession.checkValid(FlexSession.java:943) at flex.messaging.FlexSession.getUserPrincipal(FlexSession.java:254) at flex.messaging.HttpFlexSession.getUserPrincipal(HttpFlexSession.java:286) at flex.messaging.MessageBrokerServlet.service(MessageBrokerServlet.java:296) at javax.servlet.http.HttpServlet.service(HttpServlet.java:820) at weblogic.servlet.internal.StubSecurityHelper$ServletServiceAction.run(StubSecurityHelper.java:227) at weblogic.servlet.internal.StubSecurityHelper.invokeServlet(StubSecurityHelper.java:125) at weblogic.servlet.internal.ServletStubImpl.execute(ServletStubImpl.java:292) at weblogic.servlet.internal.ServletStubImpl.execute(ServletStubImpl.java:175) at weblogic.servlet.internal.WebAppServletContext$ServletInvocationAction.run(WebAppServletContext.java:3594) at weblogic.security.acl.internal.AuthenticatedSubject.doAs(AuthenticatedSubject.java:321) at weblogic.security.service.SecurityManager.runAs(SecurityManager.java:121) at weblogic.servlet.internal.WebAppServletContext.securedExecute(WebAppServletContext.java:2202) at weblogic.servlet.internal.WebAppServletContext.execute(WebAppServletContext.java:2108) at weblogic.servlet.internal.ServletRequestImpl.run(ServletRequestImpl.java:1432) at weblogic.work.ExecuteThread.execute(ExecuteThread.java:201) at weblogic.work.ExecuteThread.run(ExecuteThread.java:173) I've tried almost every option in services-config.xml: [security [login-command class="flex.messaging.security.WeblogicLoginCommand" server="Weblogic"/> [!-- Uncomment the correct app server [login-command class="flex.messaging.security.TomcatLoginCommand" server="JBoss"> [login-command class="flex.messaging.security.JRunLoginCommand" server="JRun"/> [login-command class="flex.messaging.security.TomcatLoginCommand" server="Tomcat"/> [login-command class="flex.messaging.security.WebSphereLoginCommand" server="WebSphere"/> --> [/security> I've even completely removed this section with no luck. The login functions correctly from a non-BlazeDS perspective. It authenticates the user correctly. Without authentication, BlazeDS works fine (no errors for any remote calls.) Together its a big ball of fail (invalid flexsession every time.) Has anyone got this working? Any tips?

    Read the article

  • Running multiprocess applications from MATLAB

    - by Jacob
    I've written a multitprocess application in VC++ and tried to execute it with command line arguments with the system command. It runs, but only on one core --- any suggestions? Update:In fact, it doesn't even see the second core. I used OpenMP and used omp_get_max_threads() and omp_get_thread_num() to check and omp_get_max_threads() seems to be 1 when I execute the application from MATLAB but it's 2 (as is expected) if I run it from the command window.

    Read the article

  • eventmachine on debian fails install via rubygems

    - by Max
    this has been killing me for the last 5 hours. I don't seem to be able to get eventmachine running on my debian box. here this output: $ gem install thin Building native extensions. This could take a while... ERROR: Error installing thin: ERROR: Failed to build gem native extension. /home/eventhub/.rvm/rubies/ruby-1.9.3-p125/bin/ruby extconf.rb checking for rb_trap_immediate in ruby.h,rubysig.h... no checking for rb_thread_blocking_region()... yes checking for inotify_init() in sys/inotify.h... yes checking for writev() in sys/uio.h... yes checking for rb_wait_for_single_fd()... yes checking for rb_enable_interrupt()... yes checking for rb_time_new()... yes checking for sys/event.h... no checking for epoll_create() in sys/epoll.h... yes creating Makefile make compiling kb.cpp cc1plus: warning: command line option "-Wdeclaration-after-statement" is valid for C/ObjC but not for C++ cc1plus: warning: command line option "-Wimplicit-function-declaration" is valid for C/ObjC but not for C++ In file included from project.h:149, from kb.cpp:20: binder.h:35: warning: type qualifiers ignored on function return type In file included from project.h:150, from kb.cpp:20: em.h:84: warning: type qualifiers ignored on function return type em.h:85: warning: type qualifiers ignored on function return type em.h:86: warning: type qualifiers ignored on function return type em.h:88: warning: type qualifiers ignored on function return type em.h:89: warning: type qualifiers ignored on function return type em.h:90: warning: type qualifiers ignored on function return type em.h:91: warning: type qualifiers ignored on function return type em.h:93: warning: type qualifiers ignored on function return type em.h:99: warning: type qualifiers ignored on function return type em.h:116: warning: type qualifiers ignored on function return type em.h:125: warning: type qualifiers ignored on function return type In file included from project.h:154, from kb.cpp:20: eventmachine.h:46: warning: type qualifiers ignored on function return type eventmachine.h:47: warning: type qualifiers ignored on function return type eventmachine.h:48: warning: type qualifiers ignored on function return type eventmachine.h:50: warning: type qualifiers ignored on function return type eventmachine.h:65: warning: type qualifiers ignored on function return type eventmachine.h:66: warning: type qualifiers ignored on function return type eventmachine.h:67: warning: type qualifiers ignored on function return type eventmachine.h:68: warning: type qualifiers ignored on function return type In file included from project.h:154, from kb.cpp:20: eventmachine.h:103: warning: type qualifiers ignored on function return type eventmachine.h:105: warning: type qualifiers ignored on function return type eventmachine.h:108: warning: type qualifiers ignored on function return type compiling rubymain.cpp cc1plus: warning: command line option "-Wdeclaration-after-statement" is valid for C/ObjC but not for C++ cc1plus: warning: command line option "-Wimplicit-function-declaration" is valid for C/ObjC but not for C++ In file included from project.h:149, from rubymain.cpp:20: binder.h:35: warning: type qualifiers ignored on function return type In file included from project.h:150, from rubymain.cpp:20: em.h:84: warning: type qualifiers ignored on function return type em.h:85: warning: type qualifiers ignored on function return type em.h:86: warning: type qualifiers ignored on function return type em.h:88: warning: type qualifiers ignored on function return type em.h:89: warning: type qualifiers ignored on function return type em.h:90: warning: type qualifiers ignored on function return type em.h:91: warning: type qualifiers ignored on function return type em.h:93: warning: type qualifiers ignored on function return type em.h:99: warning: type qualifiers ignored on function return type em.h:116: warning: type qualifiers ignored on function return type em.h:125: warning: type qualifiers ignored on function return type In file included from project.h:154, from rubymain.cpp:20: eventmachine.h:46: warning: type qualifiers ignored on function return type eventmachine.h:47: warning: type qualifiers ignored on function return type eventmachine.h:48: warning: type qualifiers ignored on function return type eventmachine.h:50: warning: type qualifiers ignored on function return type eventmachine.h:65: warning: type qualifiers ignored on function return type eventmachine.h:66: warning: type qualifiers ignored on function return type eventmachine.h:67: warning: type qualifiers ignored on function return type eventmachine.h:68: warning: type qualifiers ignored on function return type In file included from project.h:154, from rubymain.cpp:20: eventmachine.h:103: warning: type qualifiers ignored on function return type eventmachine.h:105: warning: type qualifiers ignored on function return type eventmachine.h:108: warning: type qualifiers ignored on function return type compiling ssl.cpp cc1plus: warning: command line option "-Wdeclaration-after-statement" is valid for C/ObjC but not for C++ cc1plus: warning: command line option "-Wimplicit-function-declaration" is valid for C/ObjC but not for C++ In file included from project.h:149, from ssl.cpp:23: binder.h:35: warning: type qualifiers ignored on function return type In file included from project.h:150, from ssl.cpp:23: em.h:84: warning: type qualifiers ignored on function return type em.h:85: warning: type qualifiers ignored on function return type em.h:86: warning: type qualifiers ignored on function return type em.h:88: warning: type qualifiers ignored on function return type em.h:89: warning: type qualifiers ignored on function return type em.h:90: warning: type qualifiers ignored on function return type em.h:91: warning: type qualifiers ignored on function return type em.h:93: warning: type qualifiers ignored on function return type em.h:99: warning: type qualifiers ignored on function return type em.h:116: warning: type qualifiers ignored on function return type em.h:125: warning: type qualifiers ignored on function return type In file included from project.h:154, from ssl.cpp:23: eventmachine.h:46: warning: type qualifiers ignored on function return type eventmachine.h:47: warning: type qualifiers ignored on function return type eventmachine.h:48: warning: type qualifiers ignored on function return type eventmachine.h:50: warning: type qualifiers ignored on function return type eventmachine.h:65: warning: type qualifiers ignored on function return type eventmachine.h:66: warning: type qualifiers ignored on function return type eventmachine.h:67: warning: type qualifiers ignored on function return type eventmachine.h:68: warning: type qualifiers ignored on function return type In file included from project.h:154, from ssl.cpp:23: eventmachine.h:103: warning: type qualifiers ignored on function return type eventmachine.h:105: warning: type qualifiers ignored on function return type eventmachine.h:108: warning: type qualifiers ignored on function return type compiling cmain.cpp cc1plus: warning: command line option "-Wdeclaration-after-statement" is valid for C/ObjC but not for C++ cc1plus: warning: command line option "-Wimplicit-function-declaration" is valid for C/ObjC but not for C++ In file included from project.h:149, from cmain.cpp:20: binder.h:35: warning: type qualifiers ignored on function return type In file included from project.h:150, from cmain.cpp:20: em.h:84: warning: type qualifiers ignored on function return type em.h:85: warning: type qualifiers ignored on function return type em.h:86: warning: type qualifiers ignored on function return type em.h:88: warning: type qualifiers ignored on function return type em.h:89: warning: type qualifiers ignored on function return type em.h:90: warning: type qualifiers ignored on function return type em.h:91: warning: type qualifiers ignored on function return type em.h:93: warning: type qualifiers ignored on function return type em.h:99: warning: type qualifiers ignored on function return type em.h:116: warning: type qualifiers ignored on function return type em.h:125: warning: type qualifiers ignored on function return type In file included from project.h:154, from cmain.cpp:20: eventmachine.h:46: warning: type qualifiers ignored on function return type eventmachine.h:47: warning: type qualifiers ignored on function return type eventmachine.h:48: warning: type qualifiers ignored on function return type eventmachine.h:50: warning: type qualifiers ignored on function return type eventmachine.h:65: warning: type qualifiers ignored on function return type eventmachine.h:66: warning: type qualifiers ignored on function return type eventmachine.h:67: warning: type qualifiers ignored on function return type eventmachine.h:68: warning: type qualifiers ignored on function return type In file included from project.h:154, from cmain.cpp:20: eventmachine.h:103: warning: type qualifiers ignored on function return type eventmachine.h:105: warning: type qualifiers ignored on function return type eventmachine.h:108: warning: type qualifiers ignored on function return type cmain.cpp:96: warning: type qualifiers ignored on function return type cmain.cpp:107: warning: type qualifiers ignored on function return type cmain.cpp:117: warning: type qualifiers ignored on function return type cmain.cpp:127: warning: type qualifiers ignored on function return type cmain.cpp:269: warning: type qualifiers ignored on function return type cmain.cpp:279: warning: type qualifiers ignored on function return type cmain.cpp:289: warning: type qualifiers ignored on function return type cmain.cpp:299: warning: type qualifiers ignored on function return type cmain.cpp:309: warning: type qualifiers ignored on function return type cmain.cpp:329: warning: type qualifiers ignored on function return type cmain.cpp:678: warning: type qualifiers ignored on function return type compiling em.cpp cc1plus: warning: command line option "-Wdeclaration-after-statement" is valid for C/ObjC but not for C++ cc1plus: warning: command line option "-Wimplicit-function-declaration" is valid for C/ObjC but not for C++ In file included from project.h:149, from em.cpp:23: binder.h:35: warning: type qualifiers ignored on function return type In file included from project.h:150, from em.cpp:23: em.h:84: warning: type qualifiers ignored on function return type em.h:85: warning: type qualifiers ignored on function return type em.h:86: warning: type qualifiers ignored on function return type em.h:88: warning: type qualifiers ignored on function return type em.h:89: warning: type qualifiers ignored on function return type em.h:90: warning: type qualifiers ignored on function return type em.h:91: warning: type qualifiers ignored on function return type em.h:93: warning: type qualifiers ignored on function return type em.h:99: warning: type qualifiers ignored on function return type em.h:116: warning: type qualifiers ignored on function return type em.h:125: warning: type qualifiers ignored on function return type In file included from project.h:154, from em.cpp:23: eventmachine.h:46: warning: type qualifiers ignored on function return type eventmachine.h:47: warning: type qualifiers ignored on function return type eventmachine.h:48: warning: type qualifiers ignored on function return type eventmachine.h:50: warning: type qualifiers ignored on function return type eventmachine.h:65: warning: type qualifiers ignored on function return type eventmachine.h:66: warning: type qualifiers ignored on function return type eventmachine.h:67: warning: type qualifiers ignored on function return type eventmachine.h:68: warning: type qualifiers ignored on function return type In file included from project.h:154, from em.cpp:23: eventmachine.h:103: warning: type qualifiers ignored on function return type eventmachine.h:105: warning: type qualifiers ignored on function return type eventmachine.h:108: warning: type qualifiers ignored on function return type em.cpp: In member function 'bool EventMachine_t::_RunEpollOnce()': em.cpp:578: warning: 'int rb_thread_select(int, fd_set*, fd_set*, fd_set*, timeval*)' is deprecated (declared at /home/eventhub/.rvm/rubies/ruby-1.9.3-p125/include/ruby-1.9.1/ruby/intern.h:379) em.cpp:578: warning: 'int rb_thread_select(int, fd_set*, fd_set*, fd_set*, timeval*)' is deprecated (declared at /home/eventhub/.rvm/rubies/ruby-1.9.3-p125/include/ruby-1.9.1/ruby/intern.h:379) em.cpp: In member function 'bool EventMachine_t::_RunSelectOnce()': em.cpp:974: warning: 'int rb_thread_select(int, fd_set*, fd_set*, fd_set*, timeval*)' is deprecated (declared at /home/eventhub/.rvm/rubies/ruby-1.9.3-p125/include/ruby-1.9.1/ruby/intern.h:379) em.cpp:974: warning: 'int rb_thread_select(int, fd_set*, fd_set*, fd_set*, timeval*)' is deprecated (declared at /home/eventhub/.rvm/rubies/ruby-1.9.3-p125/include/ruby-1.9.1/ruby/intern.h:379) em.cpp: At global scope: em.cpp:1057: warning: type qualifiers ignored on function return type em.cpp:1079: warning: type qualifiers ignored on function return type em.cpp:1265: warning: type qualifiers ignored on function return type em.cpp:1338: warning: type qualifiers ignored on function return type em.cpp:1510: warning: type qualifiers ignored on function return type em.cpp:1593: warning: type qualifiers ignored on function return type em.cpp:1856: warning: type qualifiers ignored on function return type em.cpp:1982: warning: type qualifiers ignored on function return type em.cpp:2046: warning: type qualifiers ignored on function return type em.cpp:2070: warning: type qualifiers ignored on function return type em.cpp:2142: warning: type qualifiers ignored on function return type em.cpp:2361: fatal error: error writing to /tmp/ccdlOK0T.s: No space left on device compilation terminated. make: *** [em.o] Error 1 Gem files will remain installed in /home/eventhub/.rvm/gems/ruby-1.9.3-p125/gems/eventmachine-1.0.1 for inspection. Results logged to /home/eventhub/.rvm/gems/ruby-1.9.3-p125/gems/eventmachine-1.0.1/ext/gem_make.out Any thoughts? I read a lot of different ways to solve this issue, but none of them worked. Thanks

    Read the article

  • Selenium RC Error when running tests

    - by Sheoque
    I get this error when running a number of tests in seleniums Bromine, The selenium RC version 1.0.2 outputs this: WARN - GET /selenium-server/driver/?cmd=testComplete&1=&2=&sessionId=1274d41621c64fc08c1e7ea0a58f260b HTTP/1.0 java.lang.IllegalStateException: unexpected command json={command:"open",target:"/Library/Security/Login.aspx?ReturnUrl=%2fIndex.aspx",value:""} in place before new command selectWindow could be added at org.openqa.selenium.server.CommandQueue.doCommandWithoutWaitingForARe sponse(CommandQueue.java:121) Any ideas

    Read the article

  • Extracting files from merge module

    - by Mystagogue
    All I want is a command-line tool that can extract files from a merge module (.msm) onto disk. I'm trying msidb.exe and orca.exe The documentation for orca states: Many merge module options can be specified from the command line... Extracting Files from a Merge Module Orca supports three different methods for extracting files contained in a merge module. Orca can extract the individual CAB file, extract the files into a module tree and extract the files into a source image once it has been merged into a target database... Extracting Files To extract the individual files from a merge module, use the ... -x ... option on the command line, where is the desired path to the new directory tree. The specified path is used as the root path for the extracted files. All files are extracted from the CAB file embedded in the module and placed in the specified path. The directory layout for the extracted files is based on the directory tree of the merge module. It mostly sounds like exactly what I need. But when I try it, orca simply opens up an editor (with info on the msm I specified) and then does nothing. I've tried a variety of command lines, usually starting with this: orca -x theDirectory theModule.msm I use "theDirectory" as whatever empty folder I want. Like I said - it didn't do anything. Then I tried msidb, where a couple of attempts I've made look like this: msidb -d theModule.msm -w {storage} msidb -d theModule.msm -x {stream} In both cases, I don't know what to insert for {storage} or {stream} to make it happy - I don't know what those represent. Can someone explain what I'm doing wrong with the command line options? Is there any other tool that can do this?

    Read the article

< Previous Page | 196 197 198 199 200 201 202 203 204 205 206 207  | Next Page >