Search Results

Search found 7371 results on 295 pages for 'raid card'.

Page 203/295 | < Previous Page | 199 200 201 202 203 204 205 206 207 208 209 210  | Next Page >

  • setting up/installing/configuring nginx LEMP stack on fresh VPS server

    - by Grant Tailor
    I need some help in settingup/installing and configuring nginx LEMP stack on a fresh new VPS I have. The specs of the CentOS 5.7 VPS are 2GB DDR3 ECC RAM(4GB burst), 1 core 1.5Ghz(3Ghz burst) and 100GB RAID 10 storage, unmetered bandwidth @ 100Mpbs all for a whopping $25/month(unbeatable, yeah I know :) Anyways I have followed this LEMP (will also need MySQL and PHP) stack guide on linode http://library.linode.com/lemp-guides/centos-5 but basically what I want is to be able to host multiple website on this webserver after everything is setup. I am used to using DirectAdmin control panel on other server and want to have things setup so I can host multiple websites - mostly wordpress and drupal themes. Lets say 10 websites on this nginx web server. So can someone please help me on what I need to do to take "full" advantage of nginx power and performance, while been able to easily manage these multiple websites (wordpress and drupal themes)?

    Read the article

  • Should I disable write caching on my Windows 2008 VM?

    - by javano
    I have a Windows Server 2008 x64 Standard virtual machine that runs on a machine with a hardware RAID controller, a Perc 6/i, which has a battery on-board. Doing everything I can for additional performance, I think I should disable this. Is this very dangerous though? My understand is that Battery Backed Write Caching gives a performance boost to the host OS, telling it the write was complete when they are still sitting in flash waiting to be written. However, I can't see how it would be detrimental to performance, but is there a gain (even if marginal) to enabling it / disabling it? P.s. There machine has a backup power. Here is a screen shot for clarification:

    Read the article

  • Intermittent lockups, unable to diagnose in over a year

    - by Magsol
    Here's a real doosie; I may just give my firstborn child to whomever helps me solve this problem. In July 2008, I assembled what would be my desktop computer for graduate school. Here are the specs of the machine I built: Thermaltake 750W PSU Corsair Dominator 2x2GB 240-pin SDRAM Thermaltake Tower Asus P5K Deluxe Motherboard Intel Core 2 Quad Q9300 2.5GHz CPU 2 x GeForce 8600 GT WD Caviar Blue 640GB hard drive CD burner DVD burner Soon thereafter, I ordered a new motherboard (because I was an idiot; that first motherboard supported CrossFire, not SLI), an Asus P5N-D. I was originally running Windows XP SP3. Pretty much right into the start of the fall semester, my desktop would simply lock up after awhile. If my system was largely idling, it would be after 1-3 days. If was gaming, it often happened an hour or two into my gaming session, indicating a link to activity level. Here's where it started getting interesting. I started looking at the system temps. The CPU was warmer than it should have been (~60s C), so I purchased some more efficient cooling compound a way better cooler for it. Now it hardly goes over 40 C. Intel was even kind enough to swap it out for free, just to rule it out. Lockups continued. The graphics cards were also running pretty warm: about 60 C idling. Removing one of them seemed to improve stability a little bit...as in, it wouldn't lock up quite as frequently, but still always eventually locked up. But it didn't matter which card I used or removed, the lockups continued. I reverted back to the original motherboard, the P5K Deluxe. Lockups continued. I purchased an entirely new motherboard, eVGA's nForce 750i. Lockups continued. Ran memtest86+ over and over and over, with no errors. Even RMA'd the memory. Lockups continued. Replaced the PSU with a Corsair 750W PSU. Lockups continued. Tried disconnecting all IDE drives (HDDs are SATA). Lockups continued. Replaced both graphics cards with a single Radeon HD 4980. Average temps are now always around 50 C when idling, 60 C only when gaming. Lockups continued. Throughout the whole ordeal, the system has been upgraded from Windows XP SP3 to Vista 32-bit, to Vista 64-bit, and is now at Windows 7 64-bit. Lockups have occurred at every step along the way (each OS was in place for at least a few months before the next upgrade). Edit: By "upgrade" I mean clean install each time. In addition to those reformats, I have performed many, many other reformats of the system and a reinstall of whatever OS had been previously installed in an attempt to rectify this problem, to no avail./Edit When the system locks up, there's no blue screen, no reboot, no error message of any kind. It simply freezes in place until I hit the reset button. Very, very rarely, once Windows boots back up, the system informs me that Windows has recovered from an error, but it can never find the source aside from some piece of hardware. I've swapped out every component in this computer, and there are more fans in it than I care to count...though for the sake of completeness: top 80mm case fan (out) rear 80mm case fan (out) rear 120mm case fan (out) front 120mm case fan (in) side 250mm case fan (in) giant CPU fan on-board motherboard fan (the eVGA board) triple-fan memory setup (came with the memory) PSU internal fan another 120mm fan I stuck on the underside of the video card to keep hot air from collecting at the bottom of the case I'm truly out of ideas. ANY help at all would be oh-so-very GREATLY appreciated. Thank you!

    Read the article

  • Linux stretch cluster: MD replication, DRBD or Veritas?

    - by PieterB
    For the moment there's a lot of choices for setting up a Linux cluster. For cluster manager: you can use Red Hat Cluster manager, Pacemaker or Veritas Cluster Server. The first one has the most momentum, the second one comes by default with RH subscriptions and the last one is very expensive and has a very good reputation ;-) For storage: - You can replicate LUN's using software raid / md device - You can use the network using DRBD replication, which offers a bit more flexibility - You can use Veritas Storage Foundation technology to talk to your SANs replication technology. Anyone has any recommandations or experience with these technologies?

    Read the article

  • Storage product testing

    - by wildchild
    hello, I know this is out of place (being an active member here i am coming for the help from seniors) ,but i need some information regarding storage testing ,testing of Raid arrays, SCSI, SAS ,SATA and also test carried out on fabric manager(Cisco MDS series switches). I am aware that this is an administrative forum and i would really appreciate if you could direct me to the correct forum ar links where i can learn things . @ moderators-Sorry for posting at the wrong place,i would be deleting this as soon as i get the help. Thanks !

    Read the article

  • PostgresQL on Amazon EBS volume, realistic performance, or move to something more lightweight?

    - by Peck
    Hi, I'm working on a little research project, currently running as an instance on ec2, and I'm hoping to figure out whether I'm going down the right path. We, like a thousand other people, are making use of some of twitters streaming feeds to do gather some data to have fun with and my db seems to be having problems keeping up, and queries take what seems to be a very long time. I'm not a DBA by trade, so I'll just dump some info here and add more if need be. System specs: ec2 xl, 15 gigs of ram ebs: 4 100 gb drives, raid 0. The stream we're getting we're looking at around 10k inserts per minute. 3 main tables, with the users we're tracking somewhere in the neighborhood of 26M rows currently. Is this amount of inserts on this hardware too much to ask out of ebs? Should take a look at some things with less overhead like mongodb?

    Read the article

  • 284 GiB of data, 217.4 GiB of space

    - by Malfist
    I want to reinstall my OS, but I don't have the hard drive space to backup any more (I have a RAID 1 array, so I haven't done it for a while). In my /home I have 284.8 GiB of data, and I have a spare 250 GB (or 217.4 GiB) hard drive that I've been using for backup. What type of compression algorithm (if any) is capable of this type of compression? I don't care about the time, I have a quad core though, so something that utilizes all 4 cores would be great. I have tried 7zip with no success. Ran on one core for two days and failed because of lack of space. Any ideas?

    Read the article

  • Is Dell's server software bundle necessary? (Poweredge 2950 in my case)

    - by bwerks
    Hi all, Dell includes a fair amount of software with its servers, but I'm having a hard time determining from the documentation what each of them does, and whether or not I should install it. Dell's support site (unless I'm doing it wrong) seems fairly opaque to me and its offerings fairly unstandardized in terms of their usage, so if possible I'd like to stray away from them. Specifically, I'm curious if any of the features offered are duplicated in something like Microsoft System Center. For additional background information, I'm working with a Poweredge 2950 that was just rebuilt with an expanded raid-6, but initially I just installed Server 2008 R2 directly instead of using the Build and Update utility. There's nothing of use on it at the moment so I'm totally open to wiping it again.

    Read the article

  • D-Link DNS-323 NAS firmware update

    - by Mark Beaton
    Hi all, I've got a D-Link DNS-323 NAS enclosure holding a bunch of multimedia files that I've (possibly stupidly) just updated the firmware on, from 1.03 to 1.08. The updater indicated it applied the firmware patch successfully, but after rebooting it I can no longer get into it via the web interface, either via the static IP I had assigned it before the update, or by any of the DHCP-assigned addresses that I can see are currently assigned by my router. The unit just sits there, with the drives (2x512 set up as RAID-1) thrashing away seemingly forever... So, my question - has anyone had a similar experience with one of these units? Any advice etc? I've googled the hell out of it, and can't find anything useful.

    Read the article

  • Installing W2K8 R2 on a Dell Poweredge 2850

    - by DerekT
    I'm a server novice and have been given a Dell 2850 (PERC 4e/Di). It has 3 blank HDs that I think are configured as RAID 5. I am trying to install W2K8 R2 SP1 on it. It doesn't have a DVD reader so I created an install USB. This works fine until it's time to copy files to the HD. It can't see a HD. There is an option to browse for drivers at this stage. Any idea what drivers I need and where to download them? I downloaded this driver RAID_DRVR_WIN_R227150.EXE but this failed with invalid signature. Thanks to dyasny for the link to LSI-LOGIC_MULTI-DEVICE_A00_R227150.exe.

    Read the article

  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS JBODs. In addition, how does battery-backed write cache (BBWC) play into the solution?

    Read the article

  • Issues with non-HP harddisk in HP ML 350 server?

    - by Torben Warberg Rohde
    I'm looking to buy some extra disk space for a HP ML 350 G5 server. It is for simple file-serving - not OS/system stuff. HP harddisks are insanely expensive, so I'm tempted to buy some other brand instead. I have heard that they sometime use special firmware on their disks, but I suspect that might just be HP spreading rumors to sell disks. Does anyone have experience using non-HP disks? Any features not working, or not being able to build the RAID at all? I'm looking at 2.5" SAS Seagate drives - Constellation 500 GB (7.2k) or Savvio 600 GB (10k).

    Read the article

  • Hardware recommendations / parts list for a modern, quiet ZFS NAS box - 2011-Feb edition [closed]

    - by dandv
    I want to build some really reliable storage for my data, and it seems that ZFS is the only filesystem at the moment that does live checksumming. That rules out DroboPro, so I'm looking to building a quiet ZFS NAS that would start with 4 2TB or larger hard drives. I'd like this system to be very reliable and relatively future-proof for 2-3 years, so I'm willing to invest some $$$ and buy higher end components. I did see questions here and on other forums about low-cost servers, but I'm not looking for those. I'd be super happy to go for an off-the-shelf solution, but I haven't found one that's quiet. I started doing the research (summarized on my wiki), but I realized that it just gets too complicated for what I know as a software dude, and I'm entering the analysis paralysis area. At this point, I'm basically looking for a parts list for a configuration that will work (and is modern), and I know there are folks around here who are way more competent than me. I've built computers and am comfortable assembling one and messing with *nix; I can follow guides; I just want to end the decision process for the hardware and software configuration. What I've researched so far (not that these are very modern components): Case: I think I've settled on the Antec Twelve Hundred case because it cools well, is quiet, and simply has 12 bays that allow elastic mounting. The SilverStone Raven is its counter-candidate, but I find its construction quite odd. For the PSU, I'm torn between Antec CP-850 and Nexus RX-8500, but I did this research more than a year ago. The Nexus has a very uniform power profile, and I'd rather not have the Antec spin up and down based on load. On the other hand, I'm not sure how often my file server will draw more than 400W under use. For the hard drives, I've read that WD Black drives are actually WD RE3 with a software setting changed. I'd also like to buy different drive types, not just 4 WDs. Recommendations? Right now I have a 2TB Hitachi Deskstar 7K300. For the motherboard, CPU and RAM I have no idea, other than the RAM must be ECC. I already asked a question here about ECC RAM, but I was misguided and was looking for a motherboard that would support USB 3.0 as well. I've learned to go with eSATA, or worry about USB later. Then there's the (liquid) cooling, Wi-Fi card, and FreeBSD vs. OpenSolaris Express. Lastly, I'm wondering if I can make this PC into a media server by adding a Blu-ray drive and a good sound card. But support for Blu-Ray is spotty on Linux, and I don't know if Windows 7 on VirtualBox would get sufficient hardware access to output HDMI or SPDIFF signals. (Running OpenSolaris virtualized is not an option because of the reliability risk.) Then there are HDCP concerns. Suggestions on that would be appreciated as well, but I don't want us to get sidetracked. A specific shopping list on the core components would be great, so I can start ordering, and in the meantime educate myself with regards to the other issues. Finally, I think this could become a great FAQ for those technically inclined to build their own ZFS server, but confused by the dizzying array of options out there, and I promise to compile the results and share my experience building and benchmarking the server.

    Read the article

  • Suppress log messages about 3ware disk temperature changes on CentOS?

    - by Stefan Lasiewski
    I have a number of CentOS 5 servers which use 3ware RAID controllers. These servers are bugging my team with messages about minor temperature changes, like this: Jun 8 12:32:39 HOST smartd[1231]: Device: /dev/twa0 [3ware_disk_01], SMART Usage Attribute: 194 Temperature_Celsius changed from 119 to 118 Jun 8 12:32:39 HOST smartd[1231]: Device: /dev/twa0 [3ware_disk_03], SMART Usage Attribute: 194 Temperature_Celsius changed from 122 to 121 How can I suppress these messages? According to man smartd.conf : To disable any of the 3 reports, set the corresponding limit to 0. Trailing zero arguments may be omitted. By default, all temperature reports are disabled (´-W 0´). On my systems, smartd is reporting about temperature changes by default. I tried a manual approach. In /etc/smartd.conf, I have the following: /dev/twa0 -d 3ware,1 -a -W 0 /dev/twa0 -d 3ware,3 -a -W 0 But this still does not suppress the messages. Since these messages show up in /var/log/messages, LogWatch is sending unnecessary emails every night.

    Read the article

  • How to perform diagnostics (stress test) on HP Smartarray Controller

    - by pepoluan
    At my office, we have a server that we suspect its RAID controller (HP Smartarray) is failing. A cold boot, however, does not indicate anything. Can anyone recommend me a method to stress-test the controller? Symptoms that makes me suspect a failing controller: Disk access getting slower, queue getting longer Running dmesg on the XenServer console I see many messages similar to this one: end_request: I/O error, dev tda, sector 253655584 (the sector number is never the same) When we move the VM to another physical host, we no longer see the above message Running idle (without any running VM), the dmesg no longer emit the above message A search on Google indicated that the above message is most commonly associated with a failing SmartArray controller. How can I be sure that the SmartArray controller is failing?

    Read the article

  • FreeNas running on ESXi - sometimes gets very slugish.

    - by Luma
    Hello everyone, I have a ESXi server (dual quad core, 8GB of DDR3 ram, 6x 1TB WD Blacks running in RAid 5 on the PErc 6/i controller. I have a 64bit freenas VM running, on this VM I keep about 200Gigs of stuff that my windows machines access. every now and then the throughput of this VM just dies, for example right now it can't even handle streaming a song and when I tried to transfer a folder the speed goes from 10-400KB/s. Might I add at this point that the ESXi box has dual gigabit network cards plugged into a good solid gigabit switch and other linux and windows VM's are just fine I have seen speeds over 90MB/s (frequently) The server still has ram left over (plenty actually) and cpu is very low (500-1000mhz) any ideas what could cause this? thanks. Luc

    Read the article

  • Using off-the-shelf hardware for brand-name servers; Possible? Good idea?

    - by threecheeseopera
    Is it possible or advisable to use 'regular' not-sanctioned-by-the-server-manufacturer hardware in high end servers? Often these manufacturer-supplied parts have a very high price markup, and I wonder if it's always necessary (understanding that they probably apply more rigorous requirements to this hardware). For example, Dell sells 300GB 15,000rpm serial-attached scsi drives for a certain server family for almost $600 each, while newegg sells a drive with the same specs for almost half the price http://www.newegg.com/Product/Product.aspx?Item=N82E16822116059. Do we really need to pay these high markups, especially for disks that are likely RAID-ed and so guarded against catastrophic failure?

    Read the article

  • How to speed up apache

    - by Zen_silence
    We have a server with 8Cores, 16GB of RAM and RAID 0 SAS 10K drives. Our goal is to use this to serve a fairly simple php application quickly. We have tested all other components and we think we have narrowed it down to apache is our bottleneck. I am no apache guru I have done some research and tested a couple things but when i test with JMeter launching 100 concurrent connections against the server the first 10 - 20 come back quickly 30 - 100ms but the rest take between 1000ms to 3000ms. Anyone have any ideas on what to change in our apache config to make this faster right now its a vanilla install of apache.

    Read the article

  • Identify SATA hard drive

    - by Rob Nicholson
    Very similar question to: Physically Identify the failed hard drive But for Windows 2003 this time. Scenario: Four identical SATA hard drives plugged into motherboard (no RAID controller here) Configured as single drive in Windows as a spanned volume One of them is starting to fail with error "The driver detected a controller error on \Device\Harddisk3" How do you cross-reference Harddisk3 to the physical SATA connection on the motherboard so you know which drive to replace? I know replacing this drive will trash the spanned array requiring it to be rebuilt anyway so my rough and ready solution is: Delete the spanned partition Create individual partitions on each drive labelled E: F: G: and H: and work out which one is Harddisk3 Power down, remove each disk one at a time, power-up until the drive letter disappears But this seems a rather crude method of identifying the drive. The SATA connectors will be numbered on the motherboard but I appreciate this might not cross-match to what Windows calls them. Thanks, Rob.

    Read the article

  • How to store 250TB of data and develop a backup/recovery plan?

    - by luccio
    I'm really new to this topic, so big apology for stupid questions. I have a school project and I want to know how to store 250TB of data with life-cycle for 18 months. It means every record is stored for 18 months and after this period of time can be deleted. There are 2 issues: store data backup data Due to amount of data I will probably need to combine data tapes and hard drives. I'd like to have "fast" access to 3 month old data, so ~42TB on disk. I really don't know what RAID should I use, or is here any better solution than combining disk and data tapes? Thanks for any advice, article, anything. I'm getting lost.

    Read the article

  • How do you passthrough native SATA drives to a guest on ESXi?

    - by John
    I have ESXi 4.0 running on an Intel DX58S0 Mothboardboard with an Intel Core i7 930 processor. VT-d is also enabled. I have three drives in the system, drive 0 is used for ESXi. Drive 1 and 2 contain data from an older machine and show up under the "Storage Adapters" section in configuration. I would like to allow a guest machine to access the data on these drives (as nativly as possible). I have enabled passthrough of the motherboard's built in SATA controller (Intel/Marvell 88SE6121 ). This controller shows up in my guest OS, but the guest shows no drives aside from the normal virtual drive. I have tried a Linux guest and Windows7. I have also configured the host machine to try IDE/RAID/ACHI modes for the SATA controller. Any ideas how I can configure one of my guests to get at the raw data on these drives?

    Read the article

  • Bridging a non-persistent PPP connection to wireless (or wired) in Windows XP

    - by phooze
    I have a 3G modem-like device (eMobile's D01NX, PC card style, for any Japan nerds out there) that I use to connect my PC to the Internet. I'd like to bridge this connection with another computer either via an ad-hoc wireless network, or a simple cross-over cable (either are options). However, when I open "Network Connections", I do not see the PPP connection (otherwise I could click both and bridge). I believe this is because there is software (provided by the vendor) that is handling the card directly and registering a PPP connection dynamically. When connected, an ipconfig at the command line yields: Ethernet adapter wireless: Connection-specific DNS Suffix . : Autoconfiguration IP Address. . . : 169.254.5.169 Subnet Mask . . . . . . . . . . . : 255.255.0.0 Default Gateway . . . . . . . . . : Ethernet adapter lan: Media State . . . . . . . . . . . : Media disconnected PPP adapter {B59EEDDE-A22B-48DF-93E5-04842B641257}: Connection-specific DNS Suffix . : IP Address. . . . . . . . . . . . : 114.xx.xxx.xx Subnet Mask . . . . . . . . . . . : 255.255.255.255 Default Gateway . . . . . . . . . : 114.xx.xxx.xx (I've commented out my IP address for privacy reasons, but what does appear there is a functional Internet IP address.) When I disconnect the adapter with the vendor software, the PPP connection disappears completely from the ipconfig list. Any ideas on how to do this?

    Read the article

  • MD3200i Slow Performance and Queue Depth

    - by Caleb_S
    Read performance on our SAN is slow under certain workloads. When we compare this to some local storage, we find the local storage performing 2x as fast. The SAN performs well with a high Queue Depth, and poorly with a low queue depth. However, the local storage performs well with a low Queue Depth. I'd like to know the reason for this occurring and find out what the specific limiting factor is in this situation. MD3200i iSCSI SAN ($15,000) 6 x 600GB 15k SAS RAID5 6 x 2TB 7.2k NLS RAID5 XCOPY /j Benchmark: (Slow) 15k Array - 71MB/s (Queue Depth 1) 7.2k Array- 71MB/s (Queue Depth 1) Robycopy /MT:32 Benchmark: (Fast) 15k Array - 171MB/s (Queue Depth ~12) 7.2k Array- 128MB/s (Queue Depth ~12) , , Read Performance on a Local controller is fast under the workload the SAN is slow at. , HighPoint 2230 RAID Controller ($600) 4 x 1TB 7.2k SATA RAID5 XCOPY /j Benchmark: 7.2k Array - 145MB/s (Queue Depth 1) (appears to max out the SATA bus)

    Read the article

  • Rules to choose hardware for OLTP systems (sql server)

    - by Roman Pokrovskij
    Ok. We know database size, number of concurrent users, number of transactions per minute; should choose number of processors, RAID, RAM, mirroring and clustering. There are no exact rule.. but may be there are no rules at all? In my practice in every case I have "legacy" system, and after some inspections and interview I can form an opinion how hardware and design can be improved. But every time when I meet "absolutely" new system (I guess there are no new systems, but sometimes are such tasks) I can't say anything trustful. So I'm interesting how people deal with such tasks? They map task on theirs experience or have some base formulas?

    Read the article

  • Is it safe to run an operating system from an USB flash drive?

    - by Georg
    I've got a laptop that has a broken harddisk controller. Replacing the motherboard is quite expensive. I thought about buying a flash drive and installing & running the system from it. However, I'm concerned about some things. Speed: Are they fast enough for swap memory (I've got only 1GB RAM installed.) I'm considering buying 2 or 3 of them and making them into a RAID. What about limited write cycles? How long will it last for a system that has a filesystem with journaling enabled? I'd hate to abandon it. Are there significant differences between internal SSD which are used in modern laptops like MacBooks and USB flash drives? What should I expect in 10 years when the memory wear starts kicking in?

    Read the article

< Previous Page | 199 200 201 202 203 204 205 206 207 208 209 210  | Next Page >