Search Results

Search found 11553 results on 463 pages for 'disk utility'.

Page 223/463 | < Previous Page | 219 220 221 222 223 224 225 226 227 228 229 230  | Next Page >

  • run sfc /scannow as administrator, but I am administrator

    - by Luigi
    On my windows 2003 I have to run sfc /scannow as admin. I have tried to run it as local administrator and domain administrator, but it says I need of administrator privilege ???? I have tried runas /user:administrator cmd and then on a new shell sfc /scannow. But it does not work too. The error message is: You must be an administrator running a console session in order to use the Windows File Checker utility. the error message is in italian and should be translated in english as above. The following is the cmd's screenshot of the error. I am connected as domain administrator but I run it a runas to be local admin.

    Read the article

  • LSI MegaRAID Expected Chip Temperature?

    - by Myles Gray
    We recently built a replicating SAN array from 2x Dell R720XD's, we are using LSI 9270-8i MegaRAID cards with CacheCade 2.0, BBU and Write Back cache enabled. Our cards are showing HUGE chip temperatures (97*C+ with NO disk activity!). Our R720's are in auto temp management mode so the max exhaust temp is 50*C. The MegaRAID cards are passively cooled and depend on good airflow to cool them - however is 97*C normal? - I have seen reference to 60*C max ambients but nothing for chip temp.

    Read the article

  • System Rescue CD on multiboot usb not working

    - by darkfeline
    I have a multiboot usb with System Rescue CD and GRUB2 on it. When I try to boot it, it tries to find systemrescuecd/sysrcd.dat, attempts to mount /dev/sr0 and all the partitions on /dev/sda before declaring cannot find systemrescuecd/sysrcd.dat on devices and dumping me onto a primitive shell. The relevant entries in grub.cfg: menuentry "SystemRescueCd 32bit" { linux /systemrescuecd/isolinux/rescuecd rootfs=/systemrescuecd subdir=systemrescuecd dostartx setkmap=us initrd /systemrescuecd/isolinux/initram.igz } menuentry "SystemRescueCd 64bit" { linux /systemrescuecd/isolinux/rescue64 rootfs=/systemrescuecd subdir=systemrescuecd dostartx setkmap=us initrd /systemrescuecd/isolinux/initram.igz } I think the problem is that System Rescue CD cannot see /dev/sdb, which is my usb, but I don't know where to begin to fix it. If it helps, I set up my USB with a utility called MultiSystem, which is like MultiISO for Linux.

    Read the article

  • How can I get Snow Leopard to recognize my third partition?

    - by qntmfred
    I installed Snow Leopard on my Macbook Pro. I then installed Windows 7 in a Boot Camp partition. Then using Windows 7's disk management console, I resized my Windows 7partition and created a 3rd NTFS partition for data, intending for both Windows 7 and Snow Leopard to read/write this partition. I installed MacFuse and NTFS-3G in Snow Leopard, but Snow Leopard still shows I have a single Windows 7 partition. How can I get Snow Leopard to recognize my third partition?

    Read the article

  • JBOD with PERC H810

    - by primero
    I'm wondering if anybody has ever used Dell storage products like the MD3220 array in a JBOD configuration. From what I can tell only perc h810 will work for external JBOD but that is not terribly specific, and for some reason I couldn't find many examples on the web of people configuring dell storage products as JBOD. My question is: Is it possible to connect to am MD3220 array, or other Dell arrays using a PERC h810 controller and use it as JBOD, and if so do I have to configure every disk in the array as a RAID 0 volume?

    Read the article

  • Windows7 hardlink over two different drives

    - by Sandro
    I am trying to create a hardlink on my C drive that points to a file on my D drive. I open up a terminal with Administrator privileges and try the following: C:\Users\sandro>mklink /H _vimrc D:\sandro-desktop\.vimrc The error that I get is: The system cannot move the file to a different disk drive. When I try a softlink I get the issue that for some reason changes to the link contents aren't reflected on the targeted file. Thank you!

    Read the article

  • Windows Server 2008 R2 LDAPS

    - by Chad Moran
    I have a Server 2008 R2 server with ADDS installed. I'm trying to configure HP's ILO utility to connect to it over SSL. I installed the Active Directory Certificate Service, after doing so I'm still not able to connect to LDAP over SSL. I checked the event log and it's showing warnings with Event ID 36886 saying that there aren't default credentials yet. I'm not too sure why this is happening. I haven't done anything with ADCS other than installing the service do I need to create a certificate for the server?

    Read the article

  • automate Clonezilla

    - by oidfrosty
    Is there a way to automate process to clone a disk with Clonezilla on different hardwares (centOS)? we need to make it easier as possible for the final user, right now the process is quite complex

    Read the article

  • Mac OS X Server 10.6 - Apple's software mirrored RAID worth it?

    - by Arko
    Hi, I am installing an Intel Xserve (Quad core Xeon) with Snow Leopard Server (10.6) on two 80Gb 7200rpm SATA HDs. I created a mirrored RAID set using Disk Utility with those two drives, all went fine. I was then asking myself if this is really a good idea. I know that an hardware RAID system would be better, but what about this software RAID? Have you any feedback on this? Will it work fine if one HD breaks down? Does this affect performance? [UPDATE] In short: Hardware RAID is better than software RAID which is better than none. Thank you all for the answers, they were very helpful. Especially Gordon's script to monitor failures. As Apple's software RAID is pretty silent about a drive failure.

    Read the article

  • Configuring RAID1 on HP Proliant Microserver N54L / Ubuntu 14.04.1 LTS [duplicate]

    - by Chris Beach
    This question already has an answer here: Cant find my harddrives in ubuntu installation? 2 answers I've bought a N54L and fitted two 3GB drives. Keen to get set up with RAID1. BIOS: SATA controller mode set to "RAID" RAID Option ROM utility: both physical drives set up as one logical drive When I came to install Ubuntu (14.04.1), both drives appeared during the setup process. I was only expecting to see the logical drive, although I'm a complete novice with RAID. I've read that the HP Proliant Microservers don't have "proper" RAID support, and require some kind of driver to be installed. I've tried a few HP utilities from the following apt repo: deb http://downloads.linux.hp.com/SDR/repo/mcp wheezy/current non-free On installation, most say "server not supported" Would appreciate your advice.

    Read the article

  • Windows Domain Controller: Create a test environment from a production environment

    - by Robert Coggins
    I need to create a working test environment of a domain we have. I need to have all the data from the production environment in the test environment. What is the best way to go about doing this? Here are some ideas I have but I am not sure if there is a better/recommended way of doing this. Use Vmware converter to create a VM of one of the production DCs create a VM and promo it on the real domain and move the vm to my test environment. use some kind of backup utility to backup the domain info and restore it to my vm I created. Thanks in advance for any help!

    Read the article

  • Keep getting invalid IP via WiFi

    - by nmuntz
    There is something wrong with my WiFi. I keep getting an invalid IP via DHCP (169.254.x.x), this happens for ALL wifi connections (home, office, etc). If I try a Local Ethernet connection via cable it works fine. I have tried downloading the latest drivers for my wireless adapter, resetting the TCP Stack and still have this issue. One strange thing I notice is under Device Manager, Network Adapters I have 4 "Unknown Devices" and three "Remote NDIS based Internet Sharing Device". My guess is that this belongs to McAfee. Not sure if this is related or not, anyways to try to fix this I tried downloading the NetLUIDfix.exe utility from McAfee but it didn't work. Any ideas how to solve this annoying issue? Thanks!!

    Read the article

  • Failure connecting to Dell MD3200i from XenServer 6.2 pool

    - by Tom Sparrow
    This question also asked at Citrix Forums http://forums.citrix.com/thread.jspa?threadID=332289 I have a MD3200i that is currently working fine with my Xen5.6 pool, but I cannot get a connection to the new 6.2 pool to work. I previously had a problem with a 6.0 upgrade (which is why the old pool is still on 5.6), but rolled back rather than fix it as it wasn't urgent at the time. This install is on new machines - I tried 6.1 first (which had the same problems) then 6.2 was released the second day after installation so I switched to that. I've not installed anything from the Dell resource DVD at this point - I can't find anything saying I should, and everything I have read suggests it shouldn't be necessary. I can ping all 8 ip addresses from both servers in the pool, iscsiadm -m discovery works fine, I can login to the nodes and iscsiadm reports the sessions active correctly. I've added the required sections to multipath.conf, but multipath -ll reports DM multipath kernel driver not loaded immediately after boot. The following is a log of a test session immediately after boot. root@xen3 ~]# iscsiadm -m node --loginall=all Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.101,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.101,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.104,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.102,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.103,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.104,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.102,3260] Logging in to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.103,3260] Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.101,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.101,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.104,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.102,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.103,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.104,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.130.102,3260]: successful Login to [iface: default, target: iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91, portal: 192.168.131.103,3260]: successful [root@xen3 ~]# iscsiadm -m session tcp: [1] 192.168.130.101:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [2] 192.168.131.101:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [3] 192.168.131.104:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [4] 192.168.131.102:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [5] 192.168.130.103:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [6] 192.168.130.104:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [7] 192.168.130.102:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [8] 192.168.131.103:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 [root@xen3 ~]# service multipathd restart ok Stopping multipathd daemon: [ OK ] Starting multipathd daemon: [ OK ] [root@xen3 ~]# multipath Jul 04 09:58:47 | DM multipath kernel driver not loaded Jul 04 09:58:47 | DM multipath kernel driver not loaded [root@xen3 ~]# multipath -ll Jul 04 09:59:03 | DM multipath kernel driver not loaded Jul 04 09:59:03 | DM multipath kernel driver not loaded [ root@xen3 ~]# modprobe dm_multipath [root@xen3 ~]# multipath Jul 04 10:19:50 | 36b8ca3a0e7024800194a0bd11891cd14: ignoring map create: 1Dell_Internal_Dual_SD_0123456789AB undef Dell,Internal Dual SD size=1.9G features='0' hwhandler='0' wp=undef `-+- policy='round-robin 0' prio=1 status=undef `- 7:0:0:0 sdb 8:16 undef ready running [root@xen3 ~]# multipath -ll 1Dell_Internal_Dual_SD_0123456789AB dm-1 Dell,Internal Dual SD size=1.9G features='0' hwhandler='0' wp=rw `-+- policy='round-robin 0' prio=1 status=enabled `- 7:0:0:0 sdb 8:16 active ready running [root@xen3 ~]# iscsiadm -m session tcp: [1] 192.168.130.101:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [2] 192.168.131.101:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [3] 192.168.131.104:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [4] 192.168.131.102:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [5] 192.168.130.103:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [6] 192.168.130.104:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [7] 192.168.130.102:3260,2 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 tcp: [8] 192.168.131.103:3260,1 iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 [root@xen3 ~]# dmesg | tail -n 50 [ 1161.881010] sd 8:0:0:0: [sdf] Unhandled error code [ 1161.881013] sd 8:0:0:0: [sdf] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1161.881017] sd 8:0:0:0: [sdf] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1161.881024] end_request: I/O error, dev sdf, sector 0 [ 1161.881031] Buffer I/O error on device sdf, logical block 0 [ 1161.881045] sd 15:0:0:0: [sdi] Unhandled error code [ 1161.881048] sd 15:0:0:0: [sdi] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1161.881052] sd 15:0:0:0: [sdi] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1161.881058] end_request: I/O error, dev sdi, sector 0 [ 1161.881065] Buffer I/O error on device sdi, logical block 0 [ 1161.881122] sd 9:0:0:0: [sdg] Unhandled error code [ 1161.881124] sd 9:0:0:0: [sdg] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1161.881126] sd 9:0:0:0: [sdg] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1161.881132] end_request: I/O error, dev sdg, sector 0 [ 1161.881140] Buffer I/O error on device sdg, logical block 0 [ 1168.220951] connection6:0: ping timeout of 15 secs expired, recv timeout 10, last rx 84060, last ping 85060, now 86560 [ 1168.220957] connection7:0: ping timeout of 15 secs expired, recv timeout 10, last rx 84060, last ping 85060, now 86560 [ 1168.220967] connection7:0: detected conn error (1011) [ 1168.220969] connection4:0: ping timeout of 15 secs expired, recv timeout 10, last rx 84060, last ping 85060, now 86560 [ 1168.220973] connection4:0: detected conn error (1011) [ 1168.220975] connection3:0: ping timeout of 15 secs expired, recv timeout 10, last rx 84060, last ping 85060, now 86560 [ 1168.220978] connection3:0: detected conn error (1011) [ 1168.220985] connection6:0: detected conn error (1011) [ 1168.480994] sd 14:0:0:0: [sde] Unhandled error code [ 1168.480998] sd 14:0:0:0: [sde] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1168.481001] sd 14:0:0:0: [sde] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1168.481009] end_request: I/O error, dev sde, sector 0 [ 1168.481015] Buffer I/O error on device sde, logical block 0 [ 1168.481076] sd 11:0:0:0: [sdc] Unhandled error code [ 1168.481078] sd 11:0:0:0: [sdc] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1168.481080] sd 11:0:0:0: [sdc] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1168.481087] end_request: I/O error, dev sdc, sector 0 [ 1168.481092] Buffer I/O error on device sdc, logical block 0 [ 1168.481144] sd 10:0:0:0: [sdd] Unhandled error code [ 1168.481147] sd 10:0:0:0: [sdd] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1168.481150] sd 10:0:0:0: [sdd] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1168.481156] end_request: I/O error, dev sdd, sector 0 [ 1168.481163] Buffer I/O error on device sdd, logical block 0 [ 1168.481168] sd 13:0:0:0: [sdj] Unhandled error code [ 1168.481170] sd 13:0:0:0: [sdj] Result: hostbyte=DID_TRANSPORT_DISRUPTED driverbyte=DRIVER_OK [ 1168.481172] sd 13:0:0:0: [sdj] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 1168.481178] end_request: I/O error, dev sdj, sector 0 [ 1168.481184] Buffer I/O error on device sdj, logical block 0 [ 1457.105996] device-mapper: multipath round-robin: version 1.0.0 loaded [ 1457.106155] device-mapper: multipath: Cannot access device path 8:0: -16 [ 1457.106164] device-mapper: table: 252:1: multipath: error getting device [ 1457.106172] device-mapper: ioctl: error adding target to table [ 1457.171292] device-mapper: multipath: Cannot access device path 8:0: -16 [ 1457.171299] device-mapper: table: 252:1: multipath: error getting device [ 1457.171304] device-mapper: ioctl: error adding target to table [root@xen3 ~]# fdisk -l Disk /dev/sda: 299.4 GB, 299439751168 bytes 255 heads, 63 sectors/track, 36404 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/sda1 1 5 40131 de Dell Utility /dev/sda2 * 6 528 4194304 83 Linux Partition 2 does not end on cylinder boundary. /dev/sda3 528 1050 4194304 83 Linux /dev/sda4 1050 36404 283986359+ 8e Linux LVM Disk /dev/sdb: 2040 MB, 2040528896 bytes 255 heads, 63 sectors/track, 248 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/sdb1 1 248 1992028+ 83 Linux Disk /dev/dm-1: 2040 MB, 2040528896 bytes 255 heads, 63 sectors/track, 248 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/dm-1p1 1 248 1992028+ 83 Linux [root@xen3 ~]# xe sr-probe type=lvmoiscsi device-config:target=192.168.130.101 device-config:targetIQN=iqn.1984-05.com.dell:powervault.md3200i.6782bcb0006bd850000000004ed88b91 Error code: SR_BACKEND_FAILURE_107 Error parameters: , The SCSIid parameter is missing or incorrect, <?xml version="1.0" ?> <iscsi-target/> Note: the xml ends there correctly on the last line - it doesn't ever return a list of LUNs (and there is one in the group on the SAN for those servers.

    Read the article

  • Re-Calibrate Toshiba battery meter with Windows 7

    - by Mark Henderson
    I have a Toshiba U300 laptop. Back in the olden days (circa-2000) you could re-calibrate the battery meter from the BIOS when your battery was no longer reading accurately. My battery was shot, so I bought a brand new one, however Windows 7 still seems to count down the battery life in at the same speed as the old one did. This time, when it alleged 0%, I turned the laptop back on and got another 90 minutes of life out of it, at 0%. Is there a tool or utility for Toshiba laptops that can fix it back to being accurate? I've read the other threads on SU about cycling the battery but that just doesn't seem to do it in this case. Update: After the last cycle, the battery meter now reads 100% but the indicator on the front of the laptop is still orange (indicating not fully charged)

    Read the article

  • How to abort robocopy on first error

    - by Yurik
    When using robocopy windows utility, what flags do I set so that robocopy aborts on the very first error it sees, similar to xcopy /dry command? I need to mirror two dirs, and on occasion some files would be locked. I do not want robocopy to continue trying to copy files, or override the files that are not locked - rather the very first error should stop the whole copy process. UPDATE: I already have the /R set to 0 - unfortunately that it only applies to a single file, NOT to the whole copying process. Hence, the first file is ignored (instead of stopping the copying), but subsequent files are copied.

    Read the article

  • Linksys WRT54GC v2.0 - all connection lights flashing

    - by JC Denton
    I have just received a Linksys WRT54GC router of a friend. Apperantly it has stopped working. All lights on it are flashing apart from the power and wireless light. I have read of similar issues online but not ones describing the same set of lights flashing. I have tried connecting to the device over ethernet but failed. It's no longer accessible over wireless either. I've also tried to run the linksys utility on the cd but it failed to detect the presence of the device (attempted over ethernet, firewall switched off). I've tried pressing the reset button for 30 seconds and disconnection the power cable for 30 seconds but to no avail. Thanks for any thoughts

    Read the article

  • The executable is absent yet I can execute the command on the command line

    - by sharptooth
    There's such utility for Windows developers called regtlib. I have three computers - one with WinXP, another two with Win2k3. If I run built-in Windows search for file with wildcard regtlib* on the whole filesystem search finds nothing on all three computers. If I try to execute regtlib on WinXP command line it says it can't find such a file or built-in command. The same on one of the two Win2k3 computers. But when I do that on the other Win2k3 computer I see typical regtlib output. What happens? What is the magic that invokes regtlib without the file being present on the filesystem?

    Read the article

  • Airport Extreme roaming setup

    - by Daniel Johansson
    We've got three Apple AirPort extremes and want to setup them as a roaming wlan network on my company. My question is what's the correct setup for this? All three AP:s is supposed to create the same wireless network "MyWlan" and we want roaming supoprt between them so that client can move from floor to floor without having to switch wlan or reconnect. We don't want to use any kind of DHCP or NAT on the AirPorts, only bridge mode. Do we connect the AirPorts to the lan/ethernet using the WAN port or one of the LAN ports? What's the correct settings in the config utility? Have one of the AirPorts create a network and setup the other two to extend the created network from AirPort 1 or have them all create the same network and set the same wlan password?

    Read the article

  • Perfmon: which counter identifies that threads are waiting?

    - by frankadelic
    While load testing an ASP.NET app, we find that the pages are taking 20-30 sec under heavy load. We suspect this is because the pages are waiting for database calls or web services. Is there a particular perfmon counter that can identify this sort of bottleneck on the web servers? CPU, Memory, and Disk are normal. Or must we use a tool other than perfmon to track down this bottleneck?

    Read the article

  • Disk2VHD image used in Win 7 as a bootable VPC

    - by John
    I have used Disk2VHD to create a VHD of my old XP Laptop's boot drive. I would like to use it as an XP virtual machine on my new Win7 machine. I have tried doingit on a second XP machine and the VPC boots properly using that VHD but under Win7 I can't get it to act as the boot disk for the VPC. Any ideas? TIA J

    Read the article

  • Xenserver 5.5 doesn't see RAID volume

    - by Roy Chan
    Hi Gurus, I am trying to install Xenserver on a Dell precision 490 workstation. After booting into the install wizard and next-ed a few times, On the disk step, it only shows physical harddrive but not the RAID (RAID-10) volume that I set up on the Dell RAID. Is there a special option that I have to set on the boot? or do I need a special driver for this? Please Advise Thanks

    Read the article