Search Results

Search found 22585 results on 904 pages for 'message generator'.

Page 266/904 | < Previous Page | 262 263 264 265 266 267 268 269 270 271 272 273  | Next Page >

  • NSIS- Error handling

    - by Pia
    I have written an installer and uninstaller in NSIS which creates and drops an sql database, which is working fine. I have written some .bat and .sql files to create and drop the database and then just call these files from NSIS script. My problem is if I keep this database open in SQL Server Management Studio and run the uninstaller ideally it should give an error message that the database is opened. In my case it shows the success message of uninstaller but dosnt drop the database properly. How can I handle this error in NSIS?

    Read the article

  • factory class, wrong number of arguments being passed to subclass constructor

    - by Hugh Bothwell
    I was looking at Python: Exception in the separated module works wrong which uses a multi-purpose GnuLibError class to 'stand in' for a variety of different errors. Each sub-error has its own ID number and error format string. I figured it would be better written as a hierarchy of Exception classes, and set out to do so: class GNULibError(Exception): sub_exceptions = 0 # patched with dict of subclasses once subclasses are created err_num = 0 err_format = None def __new__(cls, *args): print("new {}".format(cls)) # DEBUG if len(args) and args[0] in GNULibError.sub_exceptions: print(" factory -> {} {}".format(GNULibError.sub_exceptions[args[0]], args[1:])) # DEBUG return super(GNULibError, cls).__new__(GNULibError.sub_exceptions[args[0]], *(args[1:])) else: print(" plain {} {}".format(cls, args)) # DEBUG return super(GNULibError, cls).__new__(cls, *args) def __init__(self, *args): cls = type(self) print("init {} {}".format(cls, args)) # DEBUG self.args = args if cls.err_format is None: self.message = str(args) else: self.message = "[GNU Error {}] ".format(cls.err_num) + cls.err_format.format(*args) def __str__(self): return self.message def __repr__(self): return '{}{}'.format(type(self).__name__, self.args) class GNULibError_Directory(GNULibError): err_num = 1 err_format = "destination directory does not exist: {}" class GNULibError_Config(GNULibError): err_num = 2 err_format = "configure file does not exist: {}" class GNULibError_Module(GNULibError): err_num = 3 err_format = "selected module does not exist: {}" class GNULibError_Cache(GNULibError): err_num = 4 err_format = "{} is expected to contain gl_M4_BASE({})" class GNULibError_Sourcebase(GNULibError): err_num = 5 err_format = "missing sourcebase argument: {}" class GNULibError_Docbase(GNULibError): err_num = 6 err_format = "missing docbase argument: {}" class GNULibError_Testbase(GNULibError): err_num = 7 err_format = "missing testsbase argument: {}" class GNULibError_Libname(GNULibError): err_num = 8 err_format = "missing libname argument: {}" # patch master class with subclass reference # (TO DO: auto-detect all available subclasses instead of hardcoding them) GNULibError.sub_exceptions = { 1: GNULibError_Directory, 2: GNULibError_Config, 3: GNULibError_Module, 4: GNULibError_Cache, 5: GNULibError_Sourcebase, 6: GNULibError_Docbase, 7: GNULibError_Testbase, 8: GNULibError_Libname } This starts out with GNULibError as a factory class - if you call it with an error number belonging to a recognized subclass, it returns an object belonging to that subclass, otherwise it returns itself as a default error type. Based on this code, the following should be exactly equivalent (but aren't): e = GNULibError(3, 'missing.lib') f = GNULibError_Module('missing.lib') print e # -> '[GNU Error 3] selected module does not exist: 3' print f # -> '[GNU Error 3] selected module does not exist: missing.lib' I added some strategic print statements, and the error seems to be in GNULibError.__new__: >>> e = GNULibError(3, 'missing.lib') new <class '__main__.GNULibError'> factory -> <class '__main__.GNULibError_Module'> ('missing.lib',) # good... init <class '__main__.GNULibError_Module'> (3, 'missing.lib') # NO! ^ why? I call the subclass constructor as subclass.__new__(*args[1:]) - this should drop the 3, the subclass type ID - and yet its __init__ is still getting the 3 anyway! How can I trim the argument list that gets passed to subclass.__init__?

    Read the article

  • How to connect two files and use the radio button?

    - by Stupefy101
    I have here a set of form from the index.php to upload a zip file, select an option then perform a converter process. <form action="" method="post" accept-charset="utf-8"> <p class="buttons"><input type="file" value="" name="zip_file"/></p> </form> <form action="index.php" method="post" accept-charset="utf-8" name="form1"> <h3><input type="radio" name="option" value="option1"/> Option1 </h3> <h3><input type="radio" name="option" value="option2"/> Option2 </h3> <h3><input type="radio" name="option" value="option3"/> Option3 </h3> <p class="buttons"><input type="submit" value="Convert"/></p> </form> In the other hand, this is my code for the upload.php that will extract the Zip file. <?php if($_FILES["zip_file"]["name"]) { $filename = $_FILES["zip_file"]["name"]; $source = $_FILES["zip_file"]["tmp_name"]; $type = $_FILES["zip_file"]["type"]; $name = explode(".", $filename); $accepted_types = array('application/zip', 'application/x-zip-compressed', 'multipart/x-zip', 'application/x-compressed'); foreach($accepted_types as $mime_type) { if($mime_type == $type) { $okay = true; break; } } $continue = strtolower($name[1]) == 'zip' ? true : false; if(!$continue) { $message = "The file you are trying to upload is not a .zip file. Please try again."; } $target_path = "C:xampp/htdocs/themer/".$filename; // change this to the correct site path if(move_uploaded_file($source, $target_path)) { $zip = new ZipArchive(); $x = $zip->open($target_path); if ($x === true) { $zip->extractTo("C:xampp/htdocs/themer/"); // change this to the correct site path $zip->close(); unlink($target_path); } $message = "Your .zip file was uploaded and unpacked."; } else { $message = "There was a problem with the upload. Please try again."; } } ?> How can i connect both files that will perform the extracting process? And how to include the codes for radio button after submission? Please Help.

    Read the article

  • not all data insert in convert from excell to database

    - by Gold
    hi i have this code: ConnectString = @"Provider=Microsoft.ACE.OLEDB.12.0;Data Source=" + ExcelFile + ";Extended Properties=\"Excel 12.0 Xml;HDR=No\""; SheetName = SheetName.Substring(0, SheetName.Length - 5); OleDbConnection Connection = new OleDbConnection(); Connection.ConnectionString = ConnectString; try {Connection.Open();} catch (Exception EX) { MessageBox.Show(EX.Message); } OleDbDataAdapter Command = new OleDbDataAdapter("SELECT * FROM [" + SheetName + "$]", Connection); DataSet ExcelData = new DataSet(); try {Command.Fill(ExcelData);} catch (Exception EX) { MessageBox.Show(EX.Message); } finally { if (Connection.State != ConnectionState.Closed) Connection.Close(); } but not all the data in column 1 insert - i get empty data why ? what can be wrong ? thank's in advance

    Read the article

  • Stop MSVC++ debug errors from blocking the current process?

    - by Mike Arthur
    Any failed ASSERT statements on Windows cause the below debug message to appear and freeze the applications execution. I realise this is expected behaviour but it is running periodically on a headless machine so prevent the unit tests from failing, instead waiting on user input indefinitely. Is there s a registry key or compiler flag I can use to prevent this message box from requesting user input whilst still allowing the test to fail under ASSERT? Basically, I want to do this without modifying any code, just changing compiler or Windows options. Thanks!

    Read the article

  • Problems with starting windows service on windows xp SP3

    - by Michiel Peeters
    I'm currently facing a problem which I can not resolve and I really don't know what to do anymore. When I'm trying to start the service I receive the message: "The service is started but again also stopped, this because that some of the services will stop if they have nothing to do, for example the performance logs and the alerts service". I've looked into the Windows Logs but nothing is written there which could describe why my service is all the time stopping. I've also tried to fire the windows service via the command prompt which gives me the message: "The service is not started, but the service didn't return any faults.". I've tried to remove all keys which references to my service, which didn't resolve the issue. I've searched on google (maybe not good enough) to find an answer but I didn't found any. I did found some websites which describes what I could do, but all of these suggestions didn't work. This is kinda ** because I do not know where to look. I do not have any error message, i do not have any id which i can use to search on. I really don't know where to start and I hope you guys can help me on this one. Detailed explanation about the windows service OS: Windows XP SP3 .Net Framework: .Net 4.0 Client Profile Language: C# Development environment: Visual Studio 2010 Professional (but Visual Studio 2012 RC is installed) Communications: WCF (Named Pipes), WCF (BasicHTTPBinding) Named Pipes: I have chosen for this solution because I wanted to communicate from a windows service to a windows form application. It worked now for quite some time but suddenly my windows service shuts it self down and I couldn't restart it anymore. There are two named pipes services implemented: An event service which will send any notification to the windows form application and an management service which gives my windows form application the possibility to maintain my windows service. BasicHTTPBinding: The basic http binding makes the connection to a central server. This connection is then used for streaming information from the client to the server. I do not know which additional information you will need, but if you guys need something then I'll try to give it as detailed as possible. Thank you in advance.

    Read the article

  • Push notification is successfully sent, but the device does not receive (occasionally)

    - by ashiina
    I have been having a problem where some devices will not receive a push notification, since yesterday. The certificate / devicetoken seem to be correct, since the device used to successfully receive push notifications until yesterday. On the server-side, there are no errors or connection refusals, and the push notification seems to be successfully sent every time. But still, there are many occasions where the device does not correctly receive the push. Some surrounding information: I am doing this on the production environment. No errors / connection refusals on the server-side I am sending the exactly same JSON everytime. 2 of our devices are not receiving the push notification AT ALL since yesterday 1 of our device receives push notifications at a lower success rate (about 70%) than yesterday 1~2 of our devices still receive push notifications successfully even now. All of the above devices were able to receive push notifications properly on the production environment until yesterday. There is no difference in the server-side result for when the push is successful, and when the device doesn't receive it... Therefore it is virtually impossible to identify the problem. This is the server-side PHP code I am using: $ctx = stream_context_create(); stream_context_set_option($ctx, 'ssl', 'local_cert', $this->apnsData[$development]['certificate']); $fp = stream_socket_client($this->apnsData[$development]['ssl'], $error, $errorString, 100, (STREAM_CLIENT_C ONNECT|STREAM_CLIENT_PERSISTENT), $ctx); if(!$fp){ $this->_pushFailed($pid); $this->_triggerError("Failed to connect to APNS: {$error} {$errorString}."); } else { $msg = chr(0).pack("n",32).pack('H*',$token).pack("n",strlen($message)).$message; $fwrite = fwrite($fp, $msg); if(!$fwrite) { error_log("[APNS] push failed..."); $this->_pushFailed($pid); $this->_triggerError("Failed writing to stream.", E_USER_ERROR); } else { error_log("[APNS] push successful! ::: $token -> $message ($fwrite bytes)"); } } fclose($fp); The log tells me that the push was successful (Cutting out the token for privacy) : [Wed Dec 12 11:42:00 2012] [error] [client 10.161.6.177] [APNS] push successful! ::: aa4f******44 -> {"aps":{"alert":{"body":"\\u300casdfasdf\\u300d","action-loc-key":"OK"},"badge":4,"sound":"chime"}} (134 bytes) Is there any way I can get help on this problem? Or is there anybody who is having the same problem?? Please help! I am getting complaints from some users on this....

    Read the article

  • Why does the check for an interface fail?

    - by chobo
    I have a class that implements an interface. In another area of the code I check if that class instance contains that interface, but it doesn't work. The check to see if the class contains the interface always fails (false) when it should be true. Below is a simple representation of what I am trying to accomplish. Example public interface IModel { bool validate(); } public class SomeModel : IModel { public SomeModel { } public bool Validate() { return true; } } // Dummy method public void Run() { SomeModel model = new SomeModel(); if (model is IModel) { string message = "It worked"; } else { string message = "It failed"; } }

    Read the article

  • Output custom messages based on row value

    - by decimal
    I've made a simple guestbook mysql/php page. An entry is displayed if the approve column has a value of 1. For the adminstrator, I want to display either "message approved" or "not approved". Here's my code: while ($row = mysql_fetch_array ($r)) { print "<p>Guest:" .$row['name']. "</p> <p>Date:" .$row['date']. "</p> <p>Comment:". $row['comment']. "</p>"; if ($row['approve'] = '1') { print '<p>YES, the message has been approved</p>'; } else { print '<p>NO, it hasn\'t been approved</p>'; } Whatever value the if statement checks approve is equal to, all approve values are output as that value.

    Read the article

  • Continuously reading from a stream in C#?

    - by Damien Wildfire
    I have a Stream object that occasionally gets some data on it, but at unpredictable intervals. Messages that appear on the Stream are well-defined and declare the size of their payload in advance (the size is a 16-bit integer contained in the first two bytes of each message). I'd like to have a StreamWatcher class which detects when the Stream has some data on it. Once it does, I'd like an event to be raised so that a subscribed StreamProcessor instance can process the new message. Can this be done with C# events without using Threads directly? It seems like it should be straightforward, but I can't get quite get my head around the right way to design this.

    Read the article

  • Stack around variable corrupted when using cvBlobsLib (OpenCV)

    - by jpromvi
    I am trying to do simple image processing with OpenCV and the cvBlobsLib in Visual C++ 2008, and I get an error message when I try to create a CBlobResult object IplImage* original = cvLoadImage("pic6.png",0); cvThreshold(original, original, 100, 255, CV_THRESH_BINARY); CBlobResult blobs = CBlobResult(original, NULL, 255); The message is the following: Run-Time Check Failure #2 - Stack around the variable blobs was corrupted Why does this happen? How should I create this object? Thank you very much for your help.

    Read the article

  • XSL - Get attribute of previous element

    - by Chris
    In the if block below I want to be also test whether @Timestamp is smaller than the previous Message's timestamp. How can I achieve this? <xsl:for-each select="Message"> <xsl:sort select="position()" data-type="number" order="descending"/> <xsl:variable name="newclass"> <xsl:if test="@Timestamp + 60 &gt; $ctimestamp">new</xsl:if> </xsl:variable> <tr><td class="debugtime"> <xsl:value-of select="@Time"/> </td><td class="{$newclass}"> <xsl:value-of select="node()"/> </td></tr> </xsl:for-each>

    Read the article

  • Fastest way to move records from an Oracle database into SQL Server

    - by user347748
    Ok this is the scenario... I have a table in Oracle that acts like a queue... A VB.net program reads the queue and calls a stored proc in SQL Server that processes and then inserts the message into another SQL Server table and then deletes the record from the oracle table. We use a DataReader to read the records from Oracle and then call the stored proc for each of the records. The program seems to be a little slow. The stored procedure itself isn't slow. The SP by itself when called in a loop can process about 2000 records in 20 seconds. But when called from the .Net program, the execution time is about 5 records per second. I have seen that most of the time consumed is in calling the stored procedure and waiting for it to return. Is there a better way of doing this? Here is a snippet of the actual code Function StartDataXfer() As Boolean Dim status As Boolean = False Try SqlConn.Open() OraConn.Open() c.ErrorLog(Now.ToString & "--Going to Get the messages from oracle", 1) If GetMsgsFromOracle() Then c.ErrorLog(Now.ToString & "--Got messages from oracle", 1) If ProcessMessages() Then c.ErrorLog(Now.ToString & "--Finished Processing all messages in the queue", 0) status = True Else c.ErrorLog(Now.ToString & "--Failed to Process all messages in the queue", 0) status = False End If Else status = True End If StartDataXfer = status Catch ex As Exception Finally SqlConn.Close() OraConn.Close() End Try End Function Private Function GetMsgsFromOracle() As Boolean Try OraDataAdapter = New OleDb.OleDbDataAdapter OraDataTable = New System.Data.DataTable OraSelCmd = New OleDb.OleDbCommand GetMsgsFromOracle = False With OraSelCmd .CommandType = CommandType.Text .Connection = OraConn .CommandText = GetMsgSql End With OraDataAdapter.SelectCommand = OraSelCmd OraDataAdapter.Fill(OraDataTable) If OraDataTable.Rows.Count > 0 Then GetMsgsFromOracle = True End If Catch ex As Exception GetMsgsFromOracle = False End Try End Function Private Function ProcessMessages() As Boolean Try ProcessMessages = False PrepareSQLInsert() PrepOraDel() i = 0 Dim Method As Integer Dim OraDataRow As DataRow c.ErrorLog(Now.ToString & "--Going to call message sending procedure", 2) For Each OraDataRow In OraDataTable.Rows With OraDataRow Method = GetMethod(.Item(0)) SQLInsCmd.Parameters("RelLifeTime").Value = c.RelLifetime SQLInsCmd.Parameters("Param1").Value = Nothing SQLInsCmd.Parameters("ID").Value = GenerateTransactionID() ' Nothing SQLInsCmd.Parameters("UID").Value = Nothing SQLInsCmd.Parameters("Param").Value = Nothing SQLInsCmd.Parameters("Credit").Value = 0 SQLInsCmd.ExecuteNonQuery() 'check the return value If SQLInsCmd.Parameters("ReturnValue").Value = 1 And SQLInsCmd.Parameters("OutPutParam").Value = 0 Then 'success 'delete the input record from the source table once it is logged c.ErrorLog(Now.ToString & "--Moved record successfully", 2) OraDataAdapter.DeleteCommand.Parameters("P(0)").Value = OraDataRow.Item(6) OraDataAdapter.DeleteCommand.ExecuteNonQuery() c.ErrorLog(Now.ToString & "--Deleted record successfully", 2) OraDataAdapter.Update(OraDataTable) c.ErrorLog(Now.ToString & "--Committed record successfully", 2) i = i + 1 Else 'failure c.ErrorLog(Now.ToString & "--Failed to exec: " & c.DestIns & "Status: " & SQLInsCmd.Parameters("OutPutParam").Value & " and TrackId: " & SQLInsCmd.Parameters("TrackID").Value.ToString, 0) End If If File.Exists("stop.txt") Then c.ErrorLog(Now.ToString & "--Stop File Found", 1) 'ProcessMessages = True 'Exit Function Exit For End If End With Next OraDataAdapter.Update(OraDataTable) c.ErrorLog(Now.ToString & "--Updated Oracle Table", 1) c.ErrorLog(Now.ToString & "--Moved " & i & " records from Oracle to SQL Table", 1) ProcessMessages = True Catch ex As Exception ProcessMessages = False c.ErrorLog(Now.ToString & "--MoveMsgsToSQL: " & ex.Message, 0) Finally OraDataTable.Clear() OraDataTable.Dispose() OraDataAdapter.Dispose() OraDelCmd.Dispose() OraDelCmd = Nothing OraSelCmd = Nothing OraDataTable = Nothing OraDataAdapter = Nothing End Try End Function Public Function GenerateTransactionID() As Int64 Dim SeqNo As Int64 Dim qry As String Dim SqlTransCmd As New OleDb.OleDbCommand qry = " select seqno from StoreSeqNo" SqlTransCmd.CommandType = CommandType.Text SqlTransCmd.Connection = SqlConn SqlTransCmd.CommandText = qry SeqNo = SqlTransCmd.ExecuteScalar If SeqNo > 2147483647 Then qry = "update StoreSeqNo set seqno=1" SqlTransCmd.CommandText = qry SqlTransCmd.ExecuteNonQuery() GenerateTransactionID = 1 Else qry = "update StoreSeqNo set seqno=" & SeqNo + 1 SqlTransCmd.CommandText = qry SqlTransCmd.ExecuteNonQuery() GenerateTransactionID = SeqNo End If End Function Private Function PrepareSQLInsert() As Boolean 'function to prepare the insert statement for the insert into the SQL stmt using 'the sql procedure SMSProcessAndDispatch Try Dim dr As DataRow SQLInsCmd = New OleDb.OleDbCommand With SQLInsCmd .CommandType = CommandType.StoredProcedure .Connection = SqlConn .CommandText = SQLInsProc .Parameters.Add("ReturnValue", OleDb.OleDbType.Integer) .Parameters("ReturnValue").Direction = ParameterDirection.ReturnValue .Parameters.Add("OutPutParam", OleDb.OleDbType.Integer) .Parameters("OutPutParam").Direction = ParameterDirection.Output .Parameters.Add("TrackID", OleDb.OleDbType.VarChar, 70) .Parameters.Add("RelLifeTime", OleDb.OleDbType.TinyInt) .Parameters("RelLifeTime").Direction = ParameterDirection.Input .Parameters.Add("Param1", OleDb.OleDbType.VarChar, 160) .Parameters("Param1").Direction = ParameterDirection.Input .Parameters.Add("TransID", OleDb.OleDbType.VarChar, 70) .Parameters("TransID").Direction = ParameterDirection.Input .Parameters.Add("UID", OleDb.OleDbType.VarChar, 20) .Parameters("UID").Direction = ParameterDirection.Input .Parameters.Add("Param", OleDb.OleDbType.VarChar, 160) .Parameters("Param").Direction = ParameterDirection.Input .Parameters.Add("CheckCredit", OleDb.OleDbType.Integer) .Parameters("CheckCredit").Direction = ParameterDirection.Input .Prepare() End With Catch ex As Exception c.ErrorLog(Now.ToString & "--PrepareSQLInsert: " & ex.Message) End Try End Function Private Function PrepOraDel() As Boolean OraDelCmd = New OleDb.OleDbCommand Try PrepOraDel = False With OraDelCmd .CommandType = CommandType.Text .Connection = OraConn .CommandText = DelSrcSQL .Parameters.Add("P(0)", OleDb.OleDbType.VarChar, 160) 'RowID .Parameters("P(0)").Direction = ParameterDirection.Input .Prepare() End With OraDataAdapter.DeleteCommand = OraDelCmd PrepOraDel = True Catch ex As Exception PrepOraDel = False End Try End Function WHat i would like to know is, if there is anyway to speed up this program? Any ideas/suggestions would be highly appreciated... Regardss, Chetan

    Read the article

  • UnicodeDecodeError from a GET-parameter in webapp2

    - by Aneon
    I'm getting a UnicodeDecodeError when recieving a GET-parameter from webapp2 that contains unicode characters, and then using it to do a NDB query. I get the same error message when manually running a unicode() on the parameter in the handler, so there either seems to be a problem in webapp2's URL routing or I've missed something. Preferably, all GET-parameters should be converted to unicode before getting passed into the handler so I don't need to do manual conversions in all of my handlers. I actually think it's worked before in an earlier version. The full error message read: UnicodeDecodeError: 'ascii' codec can't decode byte 0xc3 in position 1: ordinal not in range(128) The GET-parameter contains the following string: göteborg. It looks fine when I raise an Exception on it, but gives me an error when I (or NDB) use unicode() on it. EDIT: In NDB, it fails on the following code: File "C:\Program Files (x86)\Google\google_appengine\google\appengine\api\datastore_types.py", line 1562, in PackString pbvalue.set_stringvalue(unicode(value).encode('utf-8')) Thanks.

    Read the article

  • Unable to locate using find element by link

    - by First Rock
    Newbie in testing. I generated a test case using Selenium, and then exported it as a Python script. Now, when I try to run that in terminal, I get following error: raise exception_class(message, screen, stacktrace) NoSuchElementException: Message: u'Unable to locate element: {"method":"link text","selector":"delete"}' I am using the command generated by Selenium i.e driver.find_element_by_link_text("delete").click() The reason for the error I believe is that the link "delete" in my web page is seen only when I click on a particular line to be deleted. So I guess it is being unable to locate the link. Please suggest what alternative measure could I use to locate and click on the "delete" link. Thanks in Advance:)

    Read the article

  • regular expression

    - by Altariste
    Hi, I need to find all invocations of some logging macros in the code. The macro invocation is of the form: DEBUG[1-5] ( "methodName: the logged message", arguments) But the new versions of the macros are prepending the name of the method automatically, so my task is to write a Python script that will remove the duplicate function names specified already by the programmer. I'm using the sub function from the re module. I plan to substitute the part indicated by || signs below : ||DEBUG[1-5] ("methodName: || the logged message", arguments) with simply DEBUG[1-5](" The problem is following: To find the expressions I want to substitute, I use the following regular expression: ((DEBUG | INFO | all other macros names )[1-5]*)\s*\(\"\w+: But it doesn't match the whole expression ( from DEBUG right to the colon ), but only the macro name, that is for example DEBUG5. Is my expression wrong or there is some quirk in the Python regex processing? ( maybe the fact that I use the DEBUG[1-5] as a subgroup has something to do with this? ) Help from anyone more knowledgable than me appreciated :).

    Read the article

  • json call with C#

    - by Vaccano
    I am trying to make a json call using C#. I made a stab at creating a call, but it did not work: public bool SendAnSMSMessage(string message) { HttpWebRequest request = (HttpWebRequest) WebRequest.Create("http://api.pennysms.com/jsonrpc"); request.Method = "POST"; request.ContentType = "application/json"; string json = "{ \"method\": \"send\", "+ " \"params\": [ "+ " \"IPutAGuidHere\", "+ " \"[email protected]\", "+ " \"MyTenDigitNumberWasHere\", "+ " \""+message+"\" " + " ] "+ "}"; StreamWriter writer = new StreamWriter(request.GetRequestStream()); writer.Write(json); writer.Close(); return true; } Any advice on how to make this work would be appreciated.

    Read the article

  • In C# or .NET, is there a way to prevent other threads from invoking methods on a particular thread?

    - by YWE
    I have a Windows Forms application with a BackgroundWorker. In a method on the main form, a MessageBox is shown and the user must click the OK button to continue. Meanwhile, while the messagebox is being displayed, the BackgroundWorker finishes executing and calls the RunWorkerCompleted event. In the method I have assigned to that event, which runs on the UI thread, the Close method is called on the form. Even though the method that shows the message box is still running, the UI thread is not blocking other threads from invoking methods on it. So the Close method gets called on the form. What I want is for the UI thread to block other threads' invokes until the method with the message box has finished. Is there an easy way to do that?

    Read the article

  • Localizing validation (error) messages in Grails

    - by John
    Hi, I try to localize error messages from the Domain classes. This is possible with the default error messages, e.g.: default.blank.message=Property [{0}] cannot be blank and localized attribute names, e.g.: customer.address.label=Customer address Where "Customer" is my domain class and address is its attribute. My problem is that I can't localize some attributes because I need specific error messages. E.g: has.to.be.a.number=Property [{0}] has to be a number contingent.size.label=Contingent size. But the message I get is "Property [size] has to be a number" instead of "Property [Contingent size] has to be a number". The messages I cant localize are following: - Property [{0}] has to be a number - Property [{0}] has to be a valid date // I can't use g:datePicker in this context

    Read the article

  • echoing our parts of an Array?

    - by Wes
    I have the following array that I get as an output from facebook: http://www.paste.to/v/1jntlnml With the following code: $stream = $facebook->api_client->stream_get('',128342905144,'0','0',30,'','','',''); foreach($stream as $wallpost) { echo '<pre>'; print_r($wallpost); echo '</pre>'; } So I get the data that I need, but I want to call the individual variables within this array. For example, echo out the [message] for each post. Since it only loops once, I cant echo $wallpost['message'] or anything similar. any idea?

    Read the article

  • ValueError: setting an array element with a sequence.

    - by MedicalMath
    This code: import numpy as p def firstfunction(): UnFilteredDuringExSummaryOfMeansArray = [] MeanOutputHeader=['TestID','ConditionName','FilterType','RRMean','HRMean','dZdtMaxVoltageMean','BZMean','ZXMean' ,'LVETMean','Z0Mean','StrokeVolumeMean','CardiacOutputMean','VelocityIndexMean'] dataMatrix = BeatByBeatMatrixOfMatrices[column] roughTrimmedMatrix = p.array(dataMatrix[1:,1:17]) trimmedMatrix = p.array(roughTrimmedMatrix,dtype=p.float64) myMeans = p.mean(trimmedMatrix,axis=0,dtype=p.float64) conditionMeansArray = [TestID,testCondition,'UnfilteredBefore',myMeans[3], myMeans[4], myMeans[6], myMeans[9] , myMeans[10], myMeans[11], myMeans[12], myMeans[13], myMeans[14], myMeans[15]] UnFilteredDuringExSummaryOfMeansArray.append(conditionMeansArray) secondfunction(UnFilteredDuringExSummaryOfMeansArray) return def secondfunction(UnFilteredDuringExSummaryOfMeansArray): RRDuringArray = p.array(UnFilteredDuringExSummaryOfMeansArray,dtype=p.float64)[1:,3] return firstfunction() Throws this error message: File "mypath\mypythonscript.py", line 3484, in secondfunction RRDuringArray = p.array(UnFilteredDuringExSummaryOfMeansArray,dtype=p.float64)[1:,3] ValueError: setting an array element with a sequence. However, this code works: import numpy as p a=range(24) b = p.reshape(a,(6,4)) c=p.array(b,dtype=p.float64)[:,2] I re-arranged the code a bit to put it into a cogent posting, but it should more or less have the same result. Can anyone show me what to do to fix the problem in the broken code above so that it stops throwing an error message?

    Read the article

< Previous Page | 262 263 264 265 266 267 268 269 270 271 272 273  | Next Page >