  • C# serial port driver wrapper class code and concept quality

    - by Ruben Trancoso
    Hi folks, Would like to know from all you guys what you think about my Serial Wrapper class. Had be a while I've beem working with serial port but never shared the code what somekind make closed to my very own vision. Would like to know if it's a good/bad approach, if the interface is enough and what more you see on it. I know that Stackoverflow is for question but at the same time there's a lot of very good skilled people here and share code and opinion can also bennefit everybody, it's why I decided to post it anyway. thanks! using System.Text; using System.IO; using System.IO.Ports; using System; namespace Driver { class SerialSingleton { // The singleton instance reference private static SerialSingleton instance = null; // System's serial port interface private SerialPort serial; // Current com port identifier private string comPort = null; // Configuration parameters private int confBaudRate; private int confDataBits; private StopBits confStopBits; private Parity confParityControl; ASCIIEncoding encoding = new ASCIIEncoding(); // ================================================================================== // Constructors public static SerialSingleton getInstance() { if (instance == null) { instance = new SerialSingleton(); } return instance; } private SerialSingleton() { serial = new SerialPort(); } // =================================================================================== // Setup Methods public string ComPort { get { return comPort; } set { if (value == null) { throw new SerialException("Serial port name canot be null."); } if (nameIsComm(value)) { close(); comPort = value; } else { throw new SerialException("Serial Port '" + value + "' is not a valid com port."); } } } public void setSerial(string baudRate, int dataBits, StopBits stopBits, Parity parityControl) { if (baudRate == null) { throw new SerialException("Baud rate cannot be null"); } string[] baudRateRef = { "300", "600", "1200", "1800", "2400", "3600", "4800", "7200", "9600", "14400", "19200", "28800", "38400", "57600", "115200" }; int confBaudRate; if (findString(baudRateRef, baudRate) != -1) { confBaudRate = System.Convert.ToInt32(baudRate); } else { throw new SerialException("Baurate parameter invalid."); } int confDataBits; switch (dataBits) { case 5: confDataBits = 5; break; case 6: confDataBits = 6; break; case 7: confDataBits = 7; break; case 8: confDataBits = 8; break; default: throw new SerialException("Databits parameter invalid"); } if (stopBits == StopBits.None) { throw new SerialException("StopBits parameter cannot be NONE"); } this.confBaudRate = confBaudRate; this.confDataBits = confDataBits; this.confStopBits = stopBits; this.confParityControl = parityControl; } // ================================================================================== public string[] PortList { get { return SerialPort.GetPortNames(); } } public int PortCount { get { return SerialPort.GetPortNames().Length; } } // ================================================================================== // Open/Close Methods public void open() { open(comPort); } private void open(string comPort) { if (isOpen()) { throw new SerialException("Serial Port is Already open"); } else { if (comPort == null) { throw new SerialException("Serial Port not defined. Cannot open"); } bool found = false; if (nameIsComm(comPort)) { string portId; string[] portList = SerialPort.GetPortNames(); for (int i = 0; i < portList.Length; i++) { portId = (portList[i]); if (portId.Equals(comPort)) { found = true; break; } } } else { throw new SerialException("The com port identifier '" + comPort + "' is not a valid serial port identifier"); } if (!found) { throw new SerialException("Serial port '" + comPort + "' not found"); } serial.PortName = comPort; try { serial.Open(); } catch (UnauthorizedAccessException uaex) { throw new SerialException("Cannot open a serial port in use by another application", uaex); } try { serial.BaudRate = confBaudRate; serial.DataBits = confDataBits; serial.Parity = confParityControl; serial.StopBits = confStopBits; } catch (Exception e) { throw new SerialException("Serial port parameter invalid for '" + comPort + "'.\n" + e.Message, e); } } } public void close() { if (serial.IsOpen) { serial.Close(); } } // =================================================================================== // Auxiliary private Methods private int findString(string[] set, string search) { if (set != null) { for (int i = 0; i < set.Length; i++) { if (set[i].Equals(search)) { return i; } } } return -1; } private bool nameIsComm(string name) { int comNumber; int.TryParse(name.Substring(3), out comNumber); if (name.Substring(0, 3).Equals("COM")) { if (comNumber > -1 && comNumber < 256) { return true; } } return false; } // ================================================================================= // Device state Methods public bool isOpen() { return serial.IsOpen; } public bool hasData() { int amount = serial.BytesToRead; if (amount > 0) { return true; } else { return false; } } // ================================================================================== // Input Methods public char getChar() { int data = serial.ReadByte(); return (char)data; } public int getBytes(ref byte[] b) { int size = b.Length; char c; int counter = 0; for (counter = 0; counter < size; counter++) { if (tryGetChar(out c)) { b[counter] = (byte)c; } else { break; } } return counter; } public string getStringUntil(char x) { char c; string response = ""; while (tryGetChar(out c)) { response = response + c; if (c == x) { break; } } return response; } public bool tryGetChar(out char c) { c = (char)0x00; byte[] b = new byte[1]; long to = 10; long ft = System.Environment.TickCount + to; while (System.Environment.TickCount < ft) { if (hasData()) { int data = serial.ReadByte(); c = (char)data; return true; } } return false; } // ================================================================================ // Output Methods public void sendString(string data) { byte[] bytes = encoding.GetBytes(data); serial.Write(bytes, 0, bytes.Length); } public void sendChar(char c) { char[] data = new char[1]; data[0] = c; serial.Write(data, 0, 1); } public void sendBytes(byte[] data) { serial.Write(data, 0, data.Length); } public void clearBuffer() { if (serial.IsOpen) { serial.DiscardInBuffer(); serial.DiscardOutBuffer(); } } } }

    Read the article

  • SerialPort ReadLine() after Thread.Sleep() goes crazy

    - by Mat
    Hi everybody, I've been fighting with this issue for a day and I can't find answer for it. I am trying to read data from GPS device trough COM port in Compact Framework C#. I am using SerialPort class (actually my own ComPort class boxing SerialPort, but it adds only two fields I need, nothing special). Anyway.. I am running while loop in a separate thread which reads line from the port, analyze NMEA data, print them, catch all exceptions and then I Sleep(200) the thread, cause I need CPU for other threads... Without Sleep it works fine, but uses 100% CPU.. When I dont use Sleep after few minutes the output from COM port looks like this: GPGSA,A,3,09,12,22,17,15,27,,,,,,,2.6,1.6,2.1*3F GSA,A,3,09,12,22,17,15,27,,,,,,,2.6,1.6,2.1*3F A,A,3,09,12,22,17,15,27,,,,,,,2.6,1.6,2.1*3F ,18,12,271,24,24,05,020,24,14,04,326,25,11,03,023,*76 A,3,09,12,22,17,15,27,,,,,,,2.6,1.6,2.1*3F 3,09,12,22,17,15,27,,,,,,,2.6,1.6,2.1*3F 09,12,22,17,15,27,,,,,,,2.6,1.6,2.1*3F ,12,22,17,15,27,,,,,,,2.6,1.6,2.1*3F as you can see the same message is read few times but cut. I wonder what I'm doing wrong... My port configuration: port.ReadBufferSize = 4096; port.BaudRate = 4800; port.DataBits = 8; port.Parity = Parity.None; port.StopBits = StopBits.One; port.NewLine = "\r\n"; port.ReadTimeout = 1000; port.ReceivedBytesThreshold = 100000; And my reading function: private void processGps(){ while (!closing) { //reconnect if needed try { string sentence = port.ReadLine(); //here print the sentence //analyze the sentence (this takes some time 50-100ms) } catch (TimeoutException) { Thread.Sleep(0); } catch (IOException ioex) { //handling IO exception (some info on the screen) } Thread.Sleep(200); } } There is some more stuff in this function like reconnection if the device is lost etc.. but it is not called when the GPS is connected properly.. I was trying port.DiscardInBuffer(); after some blocks of code (in TimeoutException, after read..) Did anyone had similar problem? I really dont know what I'm doing wrong.. The only way to get rig of it is removing the last Sleep... Thanks in advance! Best Regards, Mat

    Read the article

  • Reed-Solomon encoder for embedded application (memory-efficient)

    - by bjarkef
    Hi I am looking for a very memory-efficient (like max. 500 bytes of memory for lookup tables etc.) implementation of a Reed-Solomon encoder for use in an embedded application? I am interested in coding blocks of 10 bytes with 5 bytes of parity. Speed is of little importance. Do you know any freely available implementations that I can use for this purpose? Thanks in advance.

    Read the article

  • .NET SerialPort DataReceived event thread interference with main thread

    - by Kiran
    I am writing a serial communication program using the SerialPort class in C# to interact with a strip machine connected via a RS232 cable. When i send the command to the machine it responds with some bytes depending on the command. Like when i send a "\D" command, i am expecting to download the machine program data of 180 bytes as a continous string. As per the machine's manual, it suggests as a best practice to send an unreognized characters like comma (,) character to make sure the machine is initialized before sending the first command in the cycle. My serial communication code is as follows: public class SerialHelper { SerialPort commPort = null; string currentReceived = string.Empty; string receivedStr = string.Empty; private bool CommInitialized() { try { commPort = new SerialPort(); commPort.PortName = "COM1"; if (!commPort.IsOpen) commPort.Open(); commPort.BaudRate = 9600; commPort.Parity = System.IO.Ports.Parity.None; commPort.StopBits = StopBits.One; commPort.DataBits = 8; commPort.RtsEnable = true; commPort.DtrEnable = true; commPort.DataReceived += new SerialDataReceivedEventHandler(commPort_DataReceived); return true; } catch (Exception ex) { return false; } } void commPort_DataReceived(object sender, SerialDataReceivedEventArgs e) { SerialPort currentPort = (SerialPort)sender; currentReceived = currentPort.ReadExisting(); receivedStr += currentReceived; } internal int CommIO(string outString, int outLen, ref string inBuffer, int inLen) { receivedStr = string.Empty; inBuffer = string.Empty; if (CommInitialized()) { commPort.Write(outString); } System.Threading.Thread.Sleep(1500); int i = 0; while ((receivedStr.Length < inLen) && i < 10) { System.Threading.Thread.Sleep(500); i += 1; } if (!string.IsNullOrEmpty(receivedStr)) { inBuffer = receivedStr; } commPort.Close(); return inBuffer.Length; } } I am calling this code from a windows form as follows: len = SerialHelperObj.CommIO(",",1,ref inBuffer, 4) len = SerialHelperObj.CommIO(",",1,ref inBuffer, 4) If(inBuffer == "!?*O") { len = SerialHelperObj.CommIO("\D",2,ref inBuffer, 180) } A valid return value from the serial port looks like this: \D00000010000000000010 550 3250 0000256000 and so on ... I am getting some thing like this: \D00000010D,, 000 550 D,, and so on... I feel that my comm calls are getting interferred with the one when i send commands. But i am trying to make sure the result of the comma command then initiating the actual command. but the received thread is inserting the bytes from the previous communication cycle. Can any one please shed some light into this...? I lost quite some hair just trying to get this work. I am not sure where i am doing wrong

    Read the article

  • Advice on logic circuits and serial communications

    - by Spencer Ruport
    As far as I understand the serial port so far, transferring data is done over pin 3. As shown here: There are two things that make me uncomfortable about this. The first is that it seems to imply that the two connected devices agree on a signal speed and the second is that even if they are configured to run at the same speed you run into possible synchronization issues... right? Such things can be handled I suppose but it seems like there must be a simpler method. What seems like a better approach to me would be to have one of the serial port pins send a pulse that indicates that the next bit is ready to be stored. So if we're hooking these pins up to a shift register we basically have: (some pulse pin)-clk, tx-d Is this a common practice? Is there some reason not to do this? EDIT Mike shouldn't have deleted his answer. This I2C (2 pin serial) approach seems fairly close to what I did. The serial port doesn't have a clock you're right nobugz but that's basically what I've done. See here: private void SendBytes(byte[] data) { int baudRate = 0; int byteToSend = 0; int bitToSend = 0; byte bitmask = 0; byte[] trigger = new byte[1]; trigger[0] = 0; SerialPort p; try { p = new SerialPort(cmbPorts.Text); } catch { return; } if (!int.TryParse(txtBaudRate.Text, out baudRate)) return; if (baudRate < 100) return; p.BaudRate = baudRate; for (int index = 0; index < data.Length * 8; index++) { byteToSend = (int)(index / 8); bitToSend = index - (byteToSend * 8); bitmask = (byte)System.Math.Pow(2, bitToSend); p.Open(); p.Parity = Parity.Space; p.RtsEnable = (byte)(data[byteToSend] & bitmask) > 0; s = p.BaseStream; s.WriteByte(trigger[0]); p.Close(); } } Before anyone tells me how ugly this is or how I'm destroying my transfer speeds my quick answer is I don't care about that. My point is this seems much much simpler than the method you described in your answer nobugz. And it wouldn't be as ugly if the .Net SerialPort class gave me more control over the pin signals. Are there other serial port APIs that do?

    Read the article

  • Sending an integer to COM1 using SerialPort

    - by Galwegian
    I'm having difficulty sending an integer to a serial port... I'm trying stuff like this, which run fine but I'm not picking anything up at the port. Private Sub fireToPort() Dim sPort As New SerialPort("COM1", 56000, Parity.None, 8, StopBits.One) sPort.Open() sPort.Write(New Byte() {Hex(1), 255}, 0, 0) sPort.Close() End Sub Any advice?

    Read the article

  • .NET Serial Port: Port Configuration Dialog

    - by sheepsimulator
    I'm going to be writing a small app based on the .NET SerialPort class. Is there a generic dialog available for setting the port settings, ala baud rate, data bits, stop bit, parity bit, flow control, etc? I didn't see one in the MSDN documentation, but I would think that one exists, since that stuff doesn't change.

    Read the article

  • Microphone not capturing sound on 12.04 Lenovo G580

    - by Yam Marcovic
    In both Skype and the Sound Recorder application, I am not capturing any audio from my built-in microphone. I'm not sure why. Otherwise, sound output is working well. I have tried running gstreamer-properties and setting the Default Input plugin to PulseAUdio as well (to match the output), and it didn't help. I have tried running alsamixer -V all and I only get 2 input-related entries: Capture(L R) which is on 100 and not muted (can't be either), and Analog Mic Boost which is on 20db. Extra info: Camera (video) is working well on Skype and Kamerka. Can you please help me get my microphone to work? lspci: 00:00.0 Host bridge: Intel Corporation Ivy Bridge DRAM Controller (rev 09) Subsystem: Lenovo Device 3977 Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B+ ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort+ >SERR- <PERR- INTx- Latency: 0 Capabilities: <access denied> Kernel driver in use: agpgart-intel 00:02.0 VGA compatible controller: Intel Corporation Ivy Bridge Graphics Controller (rev 09) (prog-if 00 [VGA controller]) Subsystem: Lenovo Device 3977 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B+ ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0 Interrupt: pin A routed to IRQ 42 Region 0: Memory at e0000000 (64-bit, non-prefetchable) [size=4M] Region 2: Memory at d0000000 (64-bit, prefetchable) [size=256M] Region 4: I/O ports at 3000 [size=64] Expansion ROM at <unassigned> [disabled] Capabilities: <access denied> Kernel driver in use: i915 Kernel modules: i915 00:14.0 USB controller: Intel Corporation Panther Point USB xHCI Host Controller (rev 04) (prog-if 30 [XHCI]) Subsystem: Lenovo Device 3977 Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0 Interrupt: pin A routed to IRQ 41 Region 0: Memory at e0600000 (64-bit, non-prefetchable) [size=64K] Capabilities: <access denied> Kernel driver in use: xhci_hcd 00:16.0 Communication controller: Intel Corporation Panther Point MEI Controller #1 (rev 04) Subsystem: Lenovo Device 3977 Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0 Interrupt: pin A routed to IRQ 43 Region 0: Memory at e0614000 (64-bit, non-prefetchable) [size=16] Capabilities: <access denied> Kernel driver in use: mei Kernel modules: mei 00:1a.0 USB controller: Intel Corporation Panther Point USB Enhanced Host Controller #2 (rev 04) (prog-if 20 [EHCI]) Subsystem: Lenovo Device 3977 Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0 Interrupt: pin A routed to IRQ 16 Region 0: Memory at e0619000 (32-bit, non-prefetchable) [size=1K] Capabilities: <access denied> Kernel driver in use: ehci_hcd 00:1b.0 Audio device: Intel Corporation Panther Point High Definition Audio Controller (rev 04) Subsystem: Lenovo Device 3977 Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0, Cache Line Size: 64 bytes Interrupt: pin A routed to IRQ 44 Region 0: Memory at e0610000 (64-bit, non-prefetchable) [size=16K] Capabilities: <access denied> Kernel driver in use: snd_hda_intel Kernel modules: snd-hda-intel 00:1c.0 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 1 (rev c4) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0, Cache Line Size: 64 bytes Bus: primary=00, secondary=01, subordinate=01, sec-latency=0 I/O behind bridge: 00002000-00002fff Memory behind bridge: e0500000-e05fffff Secondary status: 66MHz- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- <SERR- <PERR- BridgeCtl: Parity- SERR- NoISA- VGA- MAbort- >Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: <access denied> Kernel driver in use: pcieport Kernel modules: shpchp 00:1c.1 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 2 (rev c4) (prog-if 00 [Normal decode]) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0, Cache Line Size: 64 bytes Bus: primary=00, secondary=02, subordinate=02, sec-latency=0 Memory behind bridge: e0400000-e04fffff Secondary status: 66MHz- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- <SERR- <PERR- BridgeCtl: Parity- SERR- NoISA- VGA- MAbort- >Reset- FastB2B- PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn- Capabilities: <access denied> Kernel driver in use: pcieport Kernel modules: shpchp 00:1d.0 USB controller: Intel Corporation Panther Point USB Enhanced Host Controller #1 (rev 04) (prog-if 20 [EHCI]) Subsystem: Lenovo Device 3977 Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0 Interrupt: pin A routed to IRQ 23 Region 0: Memory at e0618000 (32-bit, non-prefetchable) [size=1K] Capabilities: <access denied> Kernel driver in use: ehci_hcd 00:1f.0 ISA bridge: Intel Corporation Panther Point LPC Controller (rev 04) Subsystem: Lenovo Device 3977 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0 Capabilities: <access denied> Kernel modules: iTCO_wdt 00:1f.2 SATA controller: Intel Corporation Panther Point 6 port SATA Controller [AHCI mode] (rev 04) (prog-if 01 [AHCI 1.0]) Subsystem: Lenovo Device 3977 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz+ UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0 Interrupt: pin B routed to IRQ 40 Region 0: I/O ports at 3088 [size=8] Region 1: I/O ports at 3094 [size=4] Region 2: I/O ports at 3080 [size=8] Region 3: I/O ports at 3090 [size=4] Region 4: I/O ports at 3060 [size=32] Region 5: Memory at e0617000 (32-bit, non-prefetchable) [size=2K] Capabilities: <access denied> Kernel driver in use: ahci 00:1f.3 SMBus: Intel Corporation Panther Point SMBus Controller (rev 04) Subsystem: Lenovo Device 3977 Control: I/O+ Mem+ BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap- 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Interrupt: pin C routed to IRQ 10 Region 0: Memory at e0615000 (64-bit, non-prefetchable) [size=256] Region 4: I/O ports at 3040 [size=32] Kernel modules: i2c-i801 01:00.0 Ethernet controller: Atheros Communications Inc. AR8162 Fast Ethernet (rev 08) Subsystem: Lenovo Device 3979 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0, Cache Line Size: 64 bytes Interrupt: pin A routed to IRQ 11 Region 0: Memory at e0500000 (64-bit, non-prefetchable) [size=256K] Region 2: I/O ports at 2000 [size=128] Capabilities: <access denied> 02:00.0 Network controller: Atheros Communications Inc. AR9285 Wireless Network Adapter (PCI-Express) (rev 01) Subsystem: Lenovo Device 31a1 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0, Cache Line Size: 64 bytes Interrupt: pin A routed to IRQ 17 Region 0: Memory at e0400000 (64-bit, non-prefetchable) [size=64K] Capabilities: <access denied> Kernel driver in use: ath9k Kernel modules: ath9k aplay -l **** List of PLAYBACK Hardware Devices **** card 0: PCH [HDA Intel PCH], device 0: CONEXANT Analog [CONEXANT Analog] Subdevices: 1/1 Subdevice #0: subdevice #0 card 0: PCH [HDA Intel PCH], device 3: HDMI 0 [HDMI 0] Subdevices: 1/1 Subdevice #0: subdevice #0

    Read the article

  • Windows with putty via USB serial cable to Linux serial port - output ok, input isn't

    - by Aharon Robbins
    I am trying to get two way serial communications going between a Windows XP system and a Linux system (RHEL 5). I have /sbin/agetty -L 9600 ttyS0 in /etc/inittab. I am using a generic USB to serial adaptor on Windows (Unitek) and a null modem cable. I have putty configured for 9600 baud, 8 bits, no parity, one stop bit, no flow control. I get the login prompt from agetty in the putty window but input does not work; I see weird characters in the putty screen. I can echo output into the device from windows and see it, but cat < /dev/ttyS0 just prints out weird characters from what I type. Any and all suggestions will be welcome. Thanks!

    Read the article

  • How to recover from a drive failure in a RAID 5 configuration?

    - by Philip Fourie
    This morning a drive failed on our database server. The drive array (3 disks) is setup in a RAID 5 configuration. While we wait for a drive replacement we are preparing for a recovery strategy. Users are continuing to work on the system, albeit very slowly (don't know why??). How does one install the new drive - will the data for this drive automatically be rebuilt from the parity or is there another process we should follow? Edit: This is a hardware RAID controller. (Thanks for the answers so far, appreciated)

    Read the article

  • How do I connect to the serial console port os a Sunfire 280R?

    - by DrStalker
    We have a Sunfire 280R (old SPARC/Solaris server) that is refusing to come up after being relocated. We're trying to connect to the serial console port, but all we get is random gibberish on the screen. We've tried both connecting with a DB25DB9 adapter and using a DB-25-RJ45 adapter with a cisco RJ45-DB9 adapter to a windows laptop. We're configuring the laptop to 9600 baud, 8 bit, 1 stop bit, no parity. We've tried both no flow control and Xon/Xoff. We get the same results hooking up to the serial port on a working SPARC server, so it's probably something in our setup rather than a fault with the server. How do we get access to to serial console so we can work out what is stopping this box from getting to the network? Is there a special sun adapter we need to get/make to get the serial link working?

    Read the article

  • Linux software raid robustness for raid1 vs other raid levels

    - by Waxhead
    I have a raid5 running and now also a raid1 that I set up yesterday. Since raid5 calculates parity it should be able to catch silent data corruption on one disk. However for raid1 the disks are just mirrors. The more I think about it I figure that raid1 is actually quite risky. Sure it will save me from a disk failure but i might not be as good when it comes to protecting the data on disk (who is actually more important for me). How does Linux software raid actually store raid1 type data on disk? How does it know what spindle is giving corrupt data (if the disk(subsystem) is not reporting any errors) If raid1 really is not giving me data protection but rather disk protection is there some tricks I can do with mdadm to create a two disk "raid5 like" setup? e.g. loose capacity but still keep redundancy also for data!?

    Read the article

  • Distributed, Parallel, Fault-tolerant File System

    - by Eddified
    There are so many choices that it's hard to know where to start. My requirements are these: Runs on Linux Most of the files will be between 5-9 MB in size. There will also be a significant number of small-ish jpgs (100px x 100px). All of the files need to be available over http. Redundancy -- ideally it would provide the space efficiency similar to RAID 5 of 75% (in RAID 5 this would be calculated thus: with 4 identical disks, 25% of the space is used for parity = 75% efficent) Must support several petabytes of data scalable runs on commodity hardware In addition, I look for these qualities, though they are not "requirements": Stable, mature file system Lots of momentum and support etc I would like some input as to which file system works best for the given requirements. Some people at my organization are leaning towards MogileFS, but I'm not convinced of the stability and momentum of that project. GlusterFS and Lustre, based on my limited research, appear to be better supported... Thoughts?

    Read the article

  • Server 2012 Storage Pools, Raid Controller... can the Storage Pool deal with it?

    - by TomTom
    Before trying it out - I don't find any documentation. Given that Storage Pools have serious performance problems with parity, and do not rebalance data at the moment when you add discs, my preferred way to use them would be as think provisioned space, ISCSI targets - with every "Pool" running against 1 RAID that comes from a Raid controller (who also introduces SSD read and write caching - another thing missing from Storage Pools). The main question is - how does a Storage Pool handle the change in the underlying disc that can happen? I mostly talk about OCE (Online Capacity Expansion), where a disc after an expansion suddenly reports a larger space. Standard Windows allows you to use this additional space (and expand the partitions). How does a storage pool handle it?

    Read the article

  • RAID 10 over RAID 5 when using SSDs

    - by root
    I am considering implementing an iSCSI shared storage array using SATA SSDs instead of the 15k RPM SAS drives we normally purchase. We normally use RAID 10 because of spindle contention with the random IO produced by virtualized workloads. I was wondering if we could switch to RAID 5 or RAID 6 to have more usuable space now that spindle contention is less of an issue. A question in my mind is how much overhead there is from the controller calculating parity. I am aware that this configuration will not allow TRIM to function. Our current workloads are running on a Dell H800 with a 24 bay external enclosure.

    Read the article

  • C# Adds Optional and Named Arguments

    Earlier this month Microsoft released Visual Studio 2010, the .NET Framework 4.0 (which includes ASP.NET 4.0), and new versions of their core programming languages: C# 4.0 and Visual Basic 10. In designing the latest versions of C# and VB, Microsoft has worked to bring the two languages into closer parity. Certain features available in C# were missing in VB, and vice-a-versa. Last week I wrote about Visual Basic 2010's language enhancements, which include implicit line continuation, auto-implemented properties, and collection initializers - three useful features that were available in previous versions of C#. Similarly, C# 4.0 introduces new features to the C# programming language that were available in earlier versions of Visual Basic, namely optional arguments and named arguments. Optional arguments allow developers to specify default values for one or more arguments to a method. When calling such a method, these optional arguments may be omitted, in which case their default value is used. In a nutshell, optional arguments allow for a more terse syntax for method overloading. Named arguments, on the other hand, improve readability by allowing developers to indicate the name of an argument (along with its value) when calling a method. This article examines how to use optional arguments and named arguments in C# 4.0. Read on to learn more! Read More >Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • C# Adds Optional and Named Arguments

    Earlier this month Microsoft released Visual Studio 2010, the .NET Framework 4.0 (which includes ASP.NET 4.0), and new versions of their core programming languages: C# 4.0 and Visual Basic 10. In designing the latest versions of C# and VB, Microsoft has worked to bring the two languages into closer parity. Certain features available in C# were missing in VB, and vice-a-versa. Last week I wrote about Visual Basic 2010's language enhancements, which include implicit line continuation, auto-implemented properties, and collection initializers - three useful features that were available in previous versions of C#. Similarly, C# 4.0 introduces new features to the C# programming language that were available in earlier versions of Visual Basic, namely optional arguments and named arguments. Optional arguments allow developers to specify default values for one or more arguments to a method. When calling such a method, these optional arguments may be omitted, in which case their default value is used. In a nutshell, optional arguments allow for a more terse syntax for method overloading. Named arguments, on the other hand, improve readability by allowing developers to indicate the name of an argument (along with its value) when calling a method. This article examines how to use optional arguments and named arguments in C# 4.0. Read on to learn more! Read More >

    Read the article

  • ZFS Basics

    - by user12614620
    Stage 1 basics: creating a pool # zpool create $NAME $REDUNDANCY $DISK1_0..N [$REDUNDANCY $DISK2_0..N]... $NAME = name of the pool you're creating. This will also be the name of the first filesystem and, by default, be placed at the mountpoint "/$NAME" $REDUNDANCY = either mirror or raidzN, and N can be 1, 2, or 3. If you leave N off, then it defaults to 1. $DISK1_0..N = the disks assigned to the pool. Example 1: zpool create tank mirror c4t1d0 c4t2d0 name of pool: tank redundancy: mirroring disks being mirrored: c4t1d0 and c4t2d0 Capacity: size of a single disk Example 2: zpool create tank raidz c4t1d0 c4t2d0 c4t3d0 c4t4d0 c4t5d0 Here the redundancy is raidz, and there are five disks, in a 4+1 (4 data, 1 parity) config. This means that the capacity is 4 times the disk size. If the command used "raidz2" instead, then the config would be 3+2. Likewise, "raidz3" would be a 2+3 config. Example 3: zpool create tank mirror c4t1d0 c4t2d0 mirror c4t3d0 c4t4d0 This is the same as the first mirror example, except there are two mirrors now. ZFS will stripe data across both mirrors, which means that writing data will go a bit faster. Note: you cannot create a mirror of two raidzs. You can create a raidz of mirrors, but to do that requires trickery.

    Read the article

  • Eclipse and NetBeans replacing embedded IDEs (part 2 and part 3)

    - by Geertjan
    After part 1, in Embedded Insights, the series Eclipse and NetBeans replacing embedded IDEs by principal analyst Robert Cravotta continues below. Many embedded tool developers are choosing to migrate their embedded development toolset to an open source IDE platform for a number of reasons. Maintaining an up-to-date IDE with the latest ideas, innovations, and features requires continuous effort from the tool development team. In contrast to maintaining a proprietary IDE, adopting an open source IDE platform enables the tool developers to leverage the ideas and effort of the community and take advantage of advances in IDE features much sooner and without incurring the full risk of experimenting with new features in their own toolsets. Both the Eclipse and NetBeans platforms deliver regular releases that enable tool developers to more easily take advantage of the newest features in the platform architecture.  Read more of part 2 here, in an article published Thursday, May 17th, 2012. Both the NetBeans and Eclipse projects began as development environments and both evolved into platforms that support a wider array of software products. Both platforms have been actively supported and evolving open source projects that have competed and coexisted together for the past decade and this has led to a level a parity between the two platforms. From the perspective of a tool developer, applications are built the same way on either platform – the difference is in the specific terminology and tools. Read more of part 3 here, in an article published Tuesday, June 12th, 2012. And, as a bonus in this blog entry, here's how to get started creating an IDE on the NetBeans Platform:  http://netbeans.dzone.com/how-to-create-commercial-quality-ide

    Read the article

  • .NET SerialPort DataReceived event not firing

    - by Klay
    I have a WPF test app for evaluating event-based serial port communication (vs. polling the serial port). The problem is that the DataReceived event doesn't seem to be firing at all. I have a very basic WPF form with a TextBox for user input, a TextBlock for output, and a button to write the input to the serial port. Here's the code: public partial class Window1 : Window { SerialPort port; public Window1() { InitializeComponent(); port = new SerialPort("COM2", 9600, Parity.None, 8, StopBits.One); port.DataReceived += new SerialDataReceivedEventHandler(port_DataReceived); port.Open(); } void port_DataReceived(object sender, SerialDataReceivedEventArgs e) { Debug.Print("receiving!"); string data = port.ReadExisting(); Debug.Print(data); outputText.Text = data; } private void Button_Click(object sender, RoutedEventArgs e) { Debug.Print("sending: " + inputText.Text); port.WriteLine(inputText.Text); } } Now, here are the complicating factors: The laptop I'm working on has no serial ports, so I'm using a piece of software called Virtual Serial Port Emulator to setup a COM2. VSPE has worked admirably in the past, and it's not clear why it would only malfunction with .NET's SerialPort class, but I mention it just in case. When I hit the button on my form to send the data, my Hyperterminal window (connected on COM2) shows that the data is getting through. Yes, I disconnect Hyperterminal when I want to test my form's ability to read the port. I've tried opening the port before wiring up the event. No change. I've read through another post here where someone else is having a similar problem. None of that info has helped me in this case. EDIT: Here's the console version (modified from http://mark.michaelis.net/Blog/TheBasicsOfSystemIOPortsSerialPort.aspx): class Program { static SerialPort port; static void Main(string[] args) { port = new SerialPort("COM2", 9600, Parity.None, 8, StopBits.One); port.DataReceived += new SerialDataReceivedEventHandler(port_DataReceived); port.Open(); string text; do { text = Console.ReadLine(); port.Write(text + "\r\n"); } while (text.ToLower() != "q"); } public static void port_DataReceived(object sender, SerialDataReceivedEventArgs args) { string text = port.ReadExisting(); Console.WriteLine("received: " + text); } } This should eliminate any concern that it's a Threading issue (I think). This doesn't work either. Again, Hyperterminal reports the data sent through the port, but the console app doesn't seem to fire the DataReceived event. EDIT #2: I realized that I had two separate apps that should both send and receive from the serial port, so I decided to try running them simultaneously... If I type into the console app, the WPF app DataReceived event fires, with the expected threading error (which I know how to deal with). If I type into the WPF app, the console app DataReceived event fires, and it echoes the data. I'm guessing the issue is somewhere in my use of the VSPE software, which is set up to treat one serial port as both input and output. And through some weirdness of the SerialPort class, one instance of a serial port can't be both the sender and receiver. Anyway, I think it's solved.

    Read the article

  • Is the switch to Dvorak worth it?

    - by Kevin Weil
    To those who were experienced ( 70 WPM, say) typists before the switch to Dvorak -- were you faster after switching? There are a couple good SO threads on Dvorak, but they are more on how to learn or reduction in typing pain than speed before/after. I know it will take me 1-2 months to feel comfortable, but I want to know if I should expect to be faster afterward. I am a programmer and type maybe 90-110 WPM on QWERTY. EDIT: I agree that coding is not typically IO-bound, and that a minimum typing speed is sufficient. This is half from curiosity, but it will be an undertaking to achieve QWERTY parity, so I want to know if I should at least expect some asymptotic improvement.

    Read the article

  • dial windows serial modem from php

    - by bumperbox
    I am trying to dial a phone number from php (i have a client list in a database, and thought i could use it to ring them when i click on their name here is my code, it doesn't seem to work. I can hear the phone line click, but it doesn't seem to dial. maybe i am missing some command that needs to be sent prior to atdt? $device = "COM4"; exec("mode $device BAUD=9600 PARITY=n DATA=8 STOP=1 xon=off octs=off rts=on"); $comport = fopen($device, "r+b"); if ($comport === false) { die ("Failed opening com port"); } else { echo "Com Port Open"; } stream_set_blocking($comport, 0); $atcmd = "ATDT222222222222\r"; // dial fake number if (fwrite($comport, $atcmd ) === false) { die ("Failed writing to com port"); } else { echo "Wrote $atcmd to com port"; } fclose($comport);

    Read the article

  • C++ defines for a 'better' Release mode build in VS

    - by darid
    I currently use the following preprocessor defines, and various optimization settings: WIN32_LEAN_AND_MEAN VC_EXTRALEAN NOMINMAX _CRT_SECURE_NO_WARNINGS _SCL_SECURE_NO_WARNINGS _SECURE_SCL=0 _HAS_ITERATOR_DEBUGGING=0 My question is what other things do fellow SOers use, add, define, in order to get a Release Mode build from VS C++ (2008,2010) to be as performant as possible? btw, I've tried PGO etc, it does help a bit but nothing that comes to parity, also I'm not using streams, the C++ i'm talking about its more like C but making use of templates and STL algorithms. As it stands now very simple code segments flop when compared to what GCC produces on say an equivalent x86 machine running linux (2.6+ kernel) using 02. Side-Note: I believe a lot of the issues relate directly to the STL version (Dinkum) provided by MS. Could people please elaborate on experiences using STLPort etc with VS C++.

    Read the article

  • Need help with displaying the message correctly in the pole display

    - by SA
    Hi, I am using an HP RS232 pole display with the following setting: Char type: USA/Europe (default) Command mode: EPSON (default) Baud rate: 9600, n , 8, 1 (default?) Passthru None (Default) Here's the code using System.IO.Ports; private SerialPort port; port = new SerialPort("COM2", 9600, Parity.None, 8, StopBits.One); port.Handshake = Handshake.None; Port.WriteLine("Welocome to something something"); It has 2 lines consisting of 20 characters each with a total of 40 characters. I have no control how and where the characters get displayed. I have set it to accept ASCII char set and so I am able to type as is visble in the Writeline message

    Read the article

  • C++ serial port send command

    - by Ilyssis
    Hi there, I have a hardware here, wich communicates over serial port. I use MS Visual C++ 2010, and I want to send a command: <-S-> I am doing this: SerialPort^ serialPort = gcnew SerialPort(portName , 9600, Parity::None, 8, StopBits::One); serialPort->Open(); serialPort->WriteLine("<-S->"); serialPort->Close(); But the command that goes out is <-S->., and not <-S-> (please notice the point that is attached to the outgoing command). I use Free Serial Port Monitor to watch my ingoing/outcoming data. So how can I get rid of that point in <-S->. ? This is what is going out: 3C 2D 53 2D 3E 0A = <-S-. This is what I want: 3C 2D 53 2D 3E = <-S- Thanks for help.

    Read the article