Search Results

Search found 29317 results on 1173 pages for 'device control'.

Page 357/1173 | < Previous Page | 353 354 355 356 357 358 359 360 361 362 363 364  | Next Page >

  • Any way to simulate MouseOver in WPF

    - by jpierson
    I'm working on a link control in WPF which fits the text with icon links case in the Windows UX Guide. What I want is to have some text within a hyperlink that appears to the right of some image. In my case I started off by using a TextBlock that contained a Hyperlink which then contained my image and some text. <TextBlock> <Hyperlink> <Rectangle Height="16" Width="16" Fill="{StaticResource MyIconBrush}" Stretch="UniformToFill" VerticalAlignment="Center" HorizontalAlignment="Left" /> <Run>My link text</Run> </Hyperlink> </TextBlock> The problem with this however was that the image being taller than my text produced an effect where the text was aligned to the bottom. Unfortunately I haven't found any way to control the vertical alignment within the TextBlock or within the Hyperlink so I've resorted to attempting an alternative layout where the Hyperlink and the Rectangle that represent my vector icon are separated in order to get them to align properly like shown below. <TextBlock> <Hyperlink> <StackPanel Orientation="Horizontal"> <Rectangle Height="16" Width="16" Fill="{StaticResource MyIconBrush}" Stretch="UniformToFill" VerticalAlignment="Center" HorizontalAlignment="Left" /> <TextBlock VerticalAlignment="Center"><Hyperlink>My link text<Hyperlink></TextBlock> </StackPanel> </Hyperlink> </TextBlock> The problem with this however is that now that my Icon and my Hyperlink are separated I don't get my MouseOver appearance of my link when I the mouse is over my icon and vise-versa. So this got me to thinking, how do I simulate MouseOver for a given control such with a checkbox where you get the MouseOver effect on the box when you actually mouse over it's associated text. I know in the HTML world the label element has a for attribute that can be used to specify which control it is labeling which will basically do what I'm looking for. Also I can imagine that in other scenarios it may be nice to have a label that when you mouse over shows a corresponding text box as if the mouse is over it and possibly when clicked focus is given to the corresponding text box as well. For now though I'm interested mainly in how to to get a label or label like element in WPF to act as a proxy for a given control in terms of it's MouseOver state. Also I would like to do this purely in XAML if possible.

    Read the article

  • When is it worth using a BindingSource?

    - by Justin
    I think I understand well enough what the BindingSource class does - i.e. provide a layer of indirection between a data source and a UI control. It implements the IBindingList interface and therefore also provides support for sorting. And I've used it frequently enough, without too many problems. But I'm wondering if I use it more often than I should. Perhaps an example would help. Let's say I have just a simple textbox on a form (using WinForms), and I'd like to bind that textbox to a simple property inside a class that returns a string. Is it worth using a BindingSource in this situation? Now let's say I have a grid on my form, and I'd like to bind it to a DataTable. Should I use a BindingSource now? In the latter case, I probably would not use a BindingSource, as a DataTable, from what I can gather, provides the same functionality that the BindingSource itself would. The DataTable will fire the the right events when a row is added, deleted, etc so that the grid will automatically update. But in the first case with the textbox being bound to a string, I would probably have the class that contains the string property implement INotifyPropertyChanged, so that it could fire the PropertyChanged event when the string changes. I would use a BindingSource so that it could listen to these PropertyChanged events so that it could update the textbox automatically when the string changes. How does this sound so far? I still feel like there's a gap in my understanding that's preventing me from seeing the whole picture. This has been a pretty vague question so far, so I'll try to ask some more specific questions - ideally the answers will reference the above examples or something similar... (1) Is it worth using a BindingSource in either of the above examples? (2) It seems that developers just "assume" that the DataTable class will do the right thing, in firing PropertyChanged events at the right time. How does one know if a data source is capable of doing this? Is there a particular interface that a data source should implement in order for developers to be able to assume this behaviour? (3) Does it matter what Control is being bound to, when considering whether or not to use a BindingSource? Or is it only the data source that should affect the decision? Perhaps the answer is (and this would seem logical enough): the Control needs to be intelligent enough to listen to the PropertyChanged events, otherwise a BindingSource is required. So how does one tell if the Control is capable of doing this? Again, is there a particular interface that developers can look for that the Control must implement? It is this confusion that has, in the past, led to me always using a BindingSource. But I'd like to understand better exactly when to use one, so that I do so only when necessary.

    Read the article

  • Clone a DataBound Checked List Box

    - by Buddhi Dananjaya
    Hi I have a DataBound CheckedListBox, I "check" few items on list box(source), then I need to clone it to new Checked List Box(target). It need to have all the data, with checked state. I have tried with following function. It is properly flowing through this function. But finally I can see items on target CheckedListBox but none of the items in target is checked. private void CloneCheckedListBox(CheckedListBox source, CheckedListBox target) { foreach (int checkedItemIndex in source.CheckedIndices) { target.SetItemChecked(checkedItemIndex, true); } } Edit: I have a User control which I have placed on a TabPage, on that User Control there is a "CheckedListBox", I do need to create a new TabPage with the user entered value on selected(current) TabPage(on User Control) So, what I have done is, create a new Tab Page, get a Copy of the User Control calling it's "Clone()" method. In "Clone()" method need to have CheckedListBox cloning feature. Here is my Cloning Code, which is on User Control... public SearchMain Clone() { SearchMain smClone = new SearchMain(); smClone.txtManufacturers.Text = this.txtManufacturers.Text; smClone.udPriceFrom.Value = this.udPriceFrom.Value; smClone.udPriceTo.Value = this.udPriceTo.Value; smClone.chkOld.Checked = this.chkOld.Checked; smClone.chkPrx.Checked = this.chkPrx.Checked; smClone.chkDisc.Checked = this.chkDisc.Checked; smClone.chkStock.Checked = this.chkStock.Checked; smClone.chkFirstDes.Checked = this.chkFirstDes.Checked; smClone.chkFirstPN.Checked = this.chkFirstPN.Checked; smClone.txtSuppPN.Text = this.txtSuppPN.Text; smClone.txtManuPN.Text = this.txtManuPN.Text; smClone.txtManufacturers.Text = this.txtManufacturers.Text; smClone.meDesAND.Text = this.meDesAND.Text; smClone.meDesOR.Text = this.meDesOR.Text; smClone.meDesNOT.Text = this.meDesNOT.Text; smClone.lbManufacSelected.Items.AddRange(this.lbManufacSelected.Items); smClone.lbSearchWithIn.Items.AddRange(this.lbSearchWithIn.Items); **CloneCheckedListBox(this.clbLang, smClone.clbLang);** // CloneCheckedListBox(this.clbTypes, smClone.clbTypes); return smClone; }

    Read the article

  • Google Chrome audit on caching

    - by Álvaro G. Vicario
    If I run an audit on my sites with Google Chrome, I get this message in the Leverage browser caching section: The following resources are missing a cache expiration. Resources that do not specify an expiration may not be cached by browsers: A list of all the pictures follows. I get a similar notice in Leverage proxy caching: Consider adding a "Cache-Control: public" header to the following resources: Apart from pictures, I also get a notice about HTML, CSS and JavaScript files: The following resources are explicitly non-cacheable. Consider making them cacheable if possible: Its funny because I've worked hard to cache all static contents (except for pictures, where I just left Apache's default settings). Firefox does indeed store all these items in cache. Is there anything I should improve in my HTTP headers? Here's the complete header set of some items as loaded after removing the browser caché. Pictures use default settings I didn't really check before, the rest should be cachéd for three hours. I can set headers with both .htaccess and PHP. PNG HTTP/1.1 200 OK Date: Sat, 31 Jul 2010 12:46:14 GMT Server: Apache Last-Modified: Thu, 18 Mar 2010 21:40:54 GMT Etag: "c48024-230-4821a15d6c580" Accept-Ranges: bytes Content-Length: 560 Keep-Alive: timeout=4 Connection: Keep-Alive Content-Type: image/png HTML HTTP/1.1 200 OK Date: Sat, 31 Jul 2010 12:46:13 GMT Server: Apache X-Powered-By: PHP/5.2.11 Expires: Sat, 31 Jul 2010 15:46:13 GMT Cache-Control: max-age=10800, s-maxage=10800, must-revalidate, proxy-revalidate Content-Encoding: gzip Vary: Accept-Encoding Last-Modified: Wed, 24 Mar 2010 20:30:36 GMT Keep-Alive: timeout=4 Connection: Keep-Alive Transfer-Encoding: chunked Content-Type: text/html; charset=ISO-8859-15 CSS HTTP/1.1 200 OK Date: Sat, 31 Jul 2010 12:48:21 GMT Server: Apache X-Powered-By: PHP/5.2.11 Expires: Sat, 31 Jul 2010 15:48:21 GMT Cache-Control: max-age=10800, s-maxage=10800, must-revalidate, proxy-revalidate Content-Encoding: gzip Vary: Accept-Encoding Last-Modified: Thu, 18 Mar 2010 21:40:12 GMT Keep-Alive: timeout=4 Connection: Keep-Alive Transfer-Encoding: chunked Content-Type: text/css JavaScript HTTP/1.1 200 OK Date: Sat, 31 Jul 2010 12:48:21 GMT Server: Apache X-Powered-By: PHP/5.2.11 Expires: Sat, 31 Jul 2010 15:48:21 GMT Cache-Control: max-age=10800, s-maxage=10800, must-revalidate, proxy-revalidate Content-Encoding: gzip Vary: Accept-Encoding Last-Modified: Thu, 18 Mar 2010 21:40:12 GMT Keep-Alive: timeout=4 Connection: Keep-Alive Transfer-Encoding: chunked Content-Type: application/x-javascript Update I've tested Jumby's suggestion and set my CSS's expire to 1 year: Cache-Control:max-age=31536000, s-maxage=31536000, must-revalidate, proxy-revalidate Connection:Keep-Alive Content-Encoding:gzip Content-Length:4198 Content-Type:text/css Date:Mon, 02 Aug 2010 20:48:56 GMT Expires:Tue, 02 Aug 2011 20:48:56 GMT Keep-Alive:timeout=5, max=99 Last-Modified:Thu, 18 Mar 2010 20:40:12 GMT Server:Apache/2.2.14 (Win32) PHP/5.3.1 Vary:Accept-Encoding X-Powered-By:PHP/5.3.1 However, Chrome still claims "explicitly non-cacheable".

    Read the article

  • SELECT SQL statement problem when getting info from an accdb in VB.Net

    - by Shane Fagan
    Hi again all, im getting the error below for this SQL statement in VB.Net SQLString = "SELECT AllPropertyDetails.PropertyID, Street, Town, County, Acres, Quotas, ResidenceDetails, Status, HighestBid, AskingPrice FROM AllPropertyDetails " SQLString += "INNER JOIN Land ON AllPropertyDetails.PropertyID = Land.PropertyID " SQLString += "WHERE Deleted = False " If PriceRadioButton.Checked = True Then SQLString += "ORDER BY AskingPrice ASC" ElseIf AcresRadioButton.Checked = True Then SQLString += "ORDER BY Acres ASC" End If Any ideas why its not working? The fields in the DB and the table names seem ok but its not working :/ System.InvalidOperationException was unhandled Message="An error occurred creating the form. See Exception.InnerException for details. The error is: No value given for one or more required parameters." Source="AuctioneerProject" StackTrace: at AuctioneerProject.My.MyProject.MyForms.Create__Instance__[T](T Instance) in 17d14f5c-a337-4978-8281-53493378c1071.vb:line 190 at AuctioneerProject.My.MyProject.MyForms.get_LandReport() at AuctioneerProject.ReportsMenu.LandButton_Click(Object sender, EventArgs e) in C:\Users\admin\Desktop\Auctioneers\AuctioneerProject\AuctioneerProject\ReportsMenu.vb:line 4 at System.Windows.Forms.Control.OnClick(EventArgs e) at System.Windows.Forms.Button.OnClick(EventArgs e) at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent) at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.ButtonBase.WndProc(Message& m) at System.Windows.Forms.Button.WndProc(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) at System.Windows.Forms.NativeWindow.DebuggableCallback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg) at System.Windows.Forms.Application.ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(Int32 dwComponentID, Int32 reason, Int32 pvLoopData) at System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.Run(ApplicationContext context) at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.OnRun() at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.DoApplicationModel() at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.Run(String[] commandLine) at AuctioneerProject.My.MyApplication.Main(String[] Args) in 17d14f5c-a337-4978-8281-53493378c1071.vb:line 81 at System.AppDomain._nExecuteAssembly(Assembly assembly, String[] args) at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart() InnerException: System.Data.OleDb.OleDbException ErrorCode=-2147217904 Message="No value given for one or more required parameters." Source="Microsoft Office Access Database Engine" StackTrace: at System.Data.OleDb.OleDbCommand.ExecuteCommandTextErrorHandling(OleDbHResult hr) at System.Data.OleDb.OleDbCommand.ExecuteCommandTextForSingleResult(tagDBPARAMS dbParams, Object& executeResult) at System.Data.OleDb.OleDbCommand.ExecuteCommandText(Object& executeResult) at System.Data.OleDb.OleDbCommand.ExecuteCommand(CommandBehavior behavior, Object& executeResult) at System.Data.OleDb.OleDbCommand.ExecuteReaderInternal(CommandBehavior behavior, String method) at System.Data.OleDb.OleDbCommand.ExecuteReader(CommandBehavior behavior) at System.Data.OleDb.OleDbCommand.ExecuteReader() at AuctioneerProject.LandReport.load_Land() in C:\Users\admin\Desktop\Auctioneers\AuctioneerProject\AuctioneerProject\LandReport.vb:line 37 at AuctioneerProject.LandReport.PriceRadioButton_CheckedChanged(Object sender, EventArgs e) in C:\Users\admin\Desktop\Auctioneers\AuctioneerProject\AuctioneerProject\LandReport.vb:line 79 at System.Windows.Forms.RadioButton.OnCheckedChanged(EventArgs e) at System.Windows.Forms.RadioButton.set_Checked(Boolean value) at AuctioneerProject.LandReport.InitializeComponent() in C:\Users\admin\Desktop\Auctioneers\AuctioneerProject\AuctioneerProject\LandReport.designer.vb:line 40 at AuctioneerProject.LandReport..ctor() in C:\Users\admin\Desktop\Auctioneers\AuctioneerProject\AuctioneerProject\LandReport.vb:line 5 InnerException:

    Read the article

  • ASP.NET Client to Server communication

    - by Nelson
    Can you help me make sense of all the different ways to communicate from browser to client in ASP.NET? I have made this a community wiki so feel free to edit my post to improve it. Specifically, I'm trying to understand in which scenario to use each one by listing how each works. I'm a little fuzzy on UpdatePanel vs CallBack (with ViewState): I know UpdatePanel always returns HTML while CallBack can return JSON. Any other major differences? ...and CallBack (without ViewState) vs WebMethod. CallBack goes through most of the Page lifecycle, WebMethod doesn't. Any other major differences? IHttpHandler Custom handler for anything (page, image, etc.) Only does what you tell it to do (light server processing) Page is an implementation of IHttpHandler If you don't need what Page provides, create a custom IHttpHandler If you are using Page but overriding Render() and not generating HTML, you probably can do it with a custom IHttpHandler (e.g. writing binary data such as images) By default can use the .axd or .ashx file extensions -- both are functionally similar .ashx doesn't have any built-in endpoints, so it's preferred by convention Regular PostBack (System.Web.UI.Page : IHttpHandler) Inherits Page Full PostBack, including ViewState and HTML control values (heavy traffic) Full Page lifecycle (heavy server processing) No JavaScript required Webpage flickers/scrolls since everything is reloaded in browser Returns full page HTML (heavy traffic) UpdatePanel (Control) Control inside Page Full PostBack, including ViewState and HTML control values (heavy traffic) Full Page lifecycle (heavy server processing) Controls outside the UpdatePanel do Render(NullTextWriter) Must use ScriptManager If no client-side JavaScript, it can fall back to regular PostBack with no JavaScript (?) No flicker/scroll since it's an async call, unless it falls back to regular postback. Can be used with master pages and user controls Has built-in support for progress bar Returns HTML for controls inside UpdatePanel (medium traffic) Client CallBack (Page, System.Web.UI.ICallbackEventHandler) Inherits Page Most of Page lifecycle (heavy server processing) Takes only data you specify (light traffic) and optionally ViewState (?) (medium traffic) Client must support JavaScript and use ScriptManager No flicker/scroll since it's an async call Can be used with master pages and user controls Returns only data you specify in format you specify (e.g. JSON, XML...) (?) (light traffic) WebMethod Class implements System.Web.Service.WebService HttpContext available through this.Context Takes only data you specify (light traffic) Server only runs the called method (light server processing) Client must support JavaScript No flicker/scroll since it's an async call Can be used with master pages and user controls Returns only data you specify, typically JSON (light traffic) Can create instance of server control to render HTML and sent back as string, but events, paging in GridView, etc. won't work PageMethods Essentially a WebMethod contained in the Page class, so most of WebMethod's bullet's apply Method must be public static, therefore no Page instance accessible HttpContext available through HttpContext.Current Accessed directly by URL Page.aspx/MethodName (e.g. with XMLHttpRequest directly or with library such as jQuery) Setting ScriptManager property EnablePageMethods="True" generates a JavaScript proxy for each WebMethod Cannot be used directly in user controls with master pages and user controls Any others?

    Read the article

  • NHibernate Tutorial Run-Time Error: HibernateException

    - by Kashif
    I'm a newbie at NHibernate so please go easy on me if I have asked a stupid question... I am following the tutorial for NHibernate posted here and am getting a run-time error of type "HibernateException" The code in question looks like this: using System; using System.Collections.Generic; using System.Linq; using System.Text; using FirstSolution; using NHibernate.Cfg; using NHibernate.Tool.hbm2ddl; using NUnit.Framework; namespace FirstSolution.Tests { [TestFixture] public class GenerateSchema_Fixture { [Test] public void Can_generate_schema() { var cfg = new Configuration(); cfg.Configure(); cfg.AddAssembly(typeof(Product).Assembly); new SchemaExport(cfg).Execute(false, true, false); } } } The line I am getting the error at is: cfg.AddAssembly(typeof(Product).Assembly); The inner-most exception is: The IDbCommand and IDbConnection implementation in the assembly System.Data.SqlServerCe could not be found And here's my stack trace: at NHibernate.Connection.ConnectionProvider.ConfigureDriver(IDictionary`2 settings) at NHibernate.Connection.ConnectionProvider.Configure(IDictionary`2 settings) at NHibernate.Connection.ConnectionProviderFactory.NewConnectionProvider(IDictionary`2 settings) at NHibernate.Tool.hbm2ddl.SchemaExport.Execute(Action`1 scriptAction, Boolean export, Boolean justDrop) at NHibernate.Tool.hbm2ddl.SchemaExport.Execute(Boolean script, Boolean export, Boolean justDrop) at FirstSolution.Tests.GenerateSchema_Fixture.Can_generate_schema() in C:\Users\Kash\Documents\Visual Studio 2010\Projects\FirstSolution\FirstSolution\GenerateSchema_Fixture.cs:line 23 at HibernateUnitTest.Form1.button1_Click(Object sender, EventArgs e) in C:\Users\Kash\Documents\Visual Studio 2010\Projects\FirstSolution\HibernateUnitTest\Form1.cs:line 23 at System.Windows.Forms.Control.OnClick(EventArgs e) at System.Windows.Forms.Button.OnClick(EventArgs e) at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent) at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.ButtonBase.WndProc(Message& m) at System.Windows.Forms.Button.WndProc(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) at System.Windows.Forms.NativeWindow.DebuggableCallback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg) at System.Windows.Forms.Application.ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(IntPtr dwComponentID, Int32 reason, Int32 pvLoopData) at System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.Run(Form mainForm) at HibernateUnitTest.Program.Main() in C:\Users\Kash\Documents\Visual Studio 2010\Projects\FirstSolution\HibernateUnitTest\Program.cs:line 18 at System.AppDomain._nExecuteAssembly(RuntimeAssembly assembly, String[] args) at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean ignoreSyncCtx) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart() I've made sure that System.Data.SqlServerCe has been referenced and that its Copy Local property is set to True. The error persists, however. Your help would be appreciated. Thanks.

    Read the article

  • UTF-8 GET using Indy 10.5.8.0 and Delphi XE2

    - by Bogdan Botezatu
    I'm writing my first Unicode application with Delphi XE2 and I've stumbled upon an issue with GET requests to an Unicode URL. Shortly put, it's a routine in a MP3 tagging application that takes a track title and an artist and queries Last.FM for the corresponding album, track no and genre. I have the following code: function GetMP3Info(artist, track: string) : TMP3Data //<---(This is a record) var TrackTitle, ArtistTitle : WideString; webquery : WideString; [....] WebQuery := UTF8Encode('http://ws.audioscrobbler.com/2.0/?method=track.getcorrection&api_key=' + apikey + '&artist=' + artist + '&track=' + track); //[processing the result in the web query, getting the correction for the artist and title] // eg: for artist := Bucovina and track := Mestecanis, the corrected values are //ArtistTitle := Bucovina; // TrackTitle := Mestecani?; //Now here is the tricky part: webquery := UTF8Encode('http://ws.audioscrobbler.com/2.0/?method=track.getInfo&api_key=' + apikey + '&artist=' + unescape(ArtistTitle) + '&track=' + unescape(TrackTitle)); //the unescape function replaces spaces (' ') with '+' to comply with the last.fm requests [some more processing] end; The webquery looks in a TMemo just right (http://ws.audioscrobbler.com/2.0/?method=track.getInfo&api_key=e5565002840xxxxxxxxxxxxxx23b98ad&artist=Bucovina&track=Mestecani?) Yet, when I try to send a GET() to the webquery using IdHTTP (with the ContentEncoding property set to 'UTF-8'), I see in Wireshark that the component is GET-ing the data to the ANSI value '/2.0/?method=track.getInfo&api_key=e5565002840xxxxxxxxxxxxxx23b98ad&artist=Bucovina&track=Mestec?ni?' Here is the full headers for the GET requests and responses: GET /2.0/?method=track.getInfo&api_key=e5565002840xxxxxxxxxxxxxx23b98ad&artist=Bucovina&track=Mestec?ni? HTTP/1.1 Content-Encoding: UTF-8 Host: ws.audioscrobbler.com Accept: text/html, */* Accept-Encoding: identity User-Agent: Mozilla/5.0 (Windows; U; Windows NT 6.1; en-US; rv:1.9.2.23) Gecko/20110920 Firefox/3.6.23 SearchToolbar/1.22011-10-16 20:20:07 HTTP/1.0 400 Bad Request Date: Tue, 09 Oct 2012 20:46:31 GMT Server: Apache/2.2.22 (Unix) X-Web-Node: www204 Access-Control-Allow-Origin: * Access-Control-Allow-Methods: POST, GET, OPTIONS Access-Control-Max-Age: 86400 Cache-Control: max-age=10 Expires: Tue, 09 Oct 2012 20:46:42 GMT Content-Length: 114 Connection: close Content-Type: text/xml; charset=utf-8; <?xml version="1.0" encoding="utf-8"?> <lfm status="failed"> <error code="6"> Track not found </error> </lfm> The question that puzzles me is am I overseeing anything related to setting the property of the tidhttp control? How can I stop the well-formated URL i'm composing in the application from getting wrongfully sent to the server? Thanks.

    Read the article

  • Hierarchy inheritance

    - by reito
    I had faced the problem. In my C++ hierarchy tree I have two branches for entities of difference nature, but same behavior - same interface. I created such hierarchy trees (first in image below). And now I want to work with Item or Base classes independetly of their nature (first or second). Then I create one abstract branch for this use. My mind build (second in image below). But it not working. Working scheme seems (third in image below). It's bad logic, I think... Do anybody have some ideas about such hierarchy inheritance? How make it more logical? More simple for understanding? Image Sorry for my english - russian internet didn't help:) Update: You ask me to be more explicit, and I will be. In my project (plugins for Adobe Framemaker) I need to work with dialogs and GUI controls. In some places I working with WinAPI controls, and some other places with FDK (internal Framemaker) controls, but I want to work throw same interface. I can't use one base class and inherite others from it, because all needed controls - is a hierarchy tree (not one class). So I have one hierarchy tree for WinAPI controls, one for FDK and one abstract tree to use anyone control. For example, there is an Edit control (WinEdit and FdkEdit realization), a Button control (WinButton and FdkButton realization) and base entity - Control (WinControl and FdkControl realization). For now I can link my classes in realization trees (Win and Fdk) with inheritence between each of them (WinControl is base class for WinButton and WinEdit; FdkControl is base class for FdkButton and FdkEdit). And I can link to abstract classes (Control is base class for WinControl and FdkControl; Edit is base class for WinEdit and FdkEdit; Button is base class for WinButton and FdkButton). But I can't link my abstract tree - compiler swears. In fact I have two hierarchy trees, that I want to inherite from another one. Update: I have done this quest! :) I used the virtual inheritence and get such scheme (http://img12.imageshack.us/img12/7782/99614779.png). Abstract tree has only absolute abstract methods. All inheritence in abstract tree are virtual. Link from realization tree to abstract are virtual. On image shown only one realization tree for simplicity. Thanks for help!

    Read the article

  • Best practices for displaying large number of images as thumbnails in c#

    - by andySF
    I got to a point where it's very difficult to get answers by debugging and tracing object, so i need some help. What I'm trying to do: A history form for my screen capture pet project. The history must list all images as thumbnails (ex: picasa). What I've done: I created a HistoryItem:UserControl. This history item has a few buttons, a check box, a label and a picture box. The buttons are for delete/edit/copy image. The check box is used for selecting one or more images and the label is for some info text. The picture box is getting the image from a public property that is a path and a method creates a proportional thumbnail to display it when the control has been loaded. This user control has two public events. One for deleting the image and one for bubbling the events for mouse enter and mouse leave trough all controls. For this I use EventBroadcastProvider. The bubbling is useful because wherever I move the mouse over the control, the buttons appear. The dispose method has been extended and I manually remove the events. All images are loaded by looping a xml file that contains the path of all images. For each image in this XML I create a new HitoryItem that is added (after a little coding to sort and limit the amount of images loaded) to a flow layout panel. The problem: When I lunch the history form, and the flow layout panel is populated with my HistoryItem custom control, my memory usage increases drastically.From 14Mb to around 100MB with 100 images loaded. By closing the history form and disposing whatever I could dispose and even trying to call GC.Collect() the memory increase remain. I search for any object that could not be disposed properly like an image or event but wherever I used them they are disposed. The problem seams to be from multiple sources. One is that the events for bubbling are not disposing properly, and the other is from the picture box itself. All of this i could see by commenting all the code to a limited version when only the custom control without any image processing and even events is loaded. Without the events the memory consumption is reduced by axiomatically 20%. So my real question is if this logic, flow layout panels and custom controls with picture boxes, is the best solution for displaying large amounts of images as thumbnails. Thank you!

    Read the article

  • Is it thread safe to read a form controls value (but not change it) without using Invoke/BeginInvoke from another thread

    - by goku_da_master
    I know you can read a gui control from a worker thread without using Invoke/BeginInvoke because my app is doing it now. The cross thread exception error is not being thrown and my System.Timers.Timer thread is able to read gui control values just fine (unlike this guy: can a worker thread read a control in the GUI?) Question 1: Given the cardinal rule of threads, should I be using Invoke/BeginInvoke to read form control values? And does this make it more thread-safe? The background to this question stems from a problem my app is having. It seems to randomly corrupt form controls another thread is referencing. (see question 2) Question 2: I have a second thread that needs to update form control values so I Invoke/BeginInvoke to update those values. Well this same thread needs a reference to those controls so it can update them. It holds a list of these controls (say DataGridViewRow objects). Sometimes (not always), the DataGridViewRow reference gets "corrupt". What I mean by corrupt, is the reference is still valid, but some of the DataGridViewRow properties are null (ex: row.Cells). Is this caused by question 1 or can you give me any tips on why this might be happening? Here's some code (the last line has the problem): public partial class MyForm : Form { void Timer_Elapsed(object sender) { // we're on a new thread (this function gets called every few seconds) UpdateUiHelper updateUiHelper = new UpdateUiHelper(this); foreach (DataGridViewRow row in dataGridView1.Rows) { object[] values = GetValuesFromDb(); updateUiHelper.UpdateRowValues(row, values[0]); } // .. do other work here updateUiHelper.UpdateUi(); } } public class UpdateUiHelper { private readonly Form _form; private Dictionary<DataGridViewRow, object> _rows; private delegate void RowDelegate(DataGridViewRow row); private readonly object _lockObject = new object(); public UpdateUiHelper(Form form) { _form = form; _rows = new Dictionary<DataGridViewRow, object>(); } public void UpdateRowValues(DataGridViewRow row, object value) { if (_rows.ContainsKey(row)) _rows[row] = value; else { lock (_lockObject) { _rows.Add(row, value); } } } public void UpdateUi() { foreach (DataGridViewRow row in _rows.Keys) { SetRowValueThreadSafe(row); } } private void SetRowValueThreadSafe(DataGridViewRow row) { if (_form.InvokeRequired) { _form.Invoke(new RowDelegate(SetRowValueThreadSafe), new object[] { row }); return; } // now we're on the UI thread object newValue = _rows[row]; row.Cells[0].Value = newValue; // randomly errors here with NullReferenceException, but row is never null! }

    Read the article

  • Tips on Migrating from AquaLogic .NET Accelerator to WebCenter WSRP Producer for .NET

    - by user647124
    This year I embarked on a journey to migrate a group of ASP.NET web applications developed to integrate with WebLogic Portal 9.2 via the AquaLogic® Interaction .NET Application Accelerator 1.0 to instead use the Oracle WebCenter WSRP Producer for .NET and integrated with WebLogic Portal 10.3.4. It has been a very winding path and this blog entry is intended to share both the lessons learned and relevant approaches that led to those learnings. Like most journeys of discovery, it was not a direct path, and there are notes to let you know when it is practical to skip a section if you are in a hurry to get from here to there. For the Curious From the perspective of necessity, this section would be better at the end. If it were there, though, it would probably be read by far fewer people, including those that are actually interested in these types of sections. Those in a hurry may skip past and be none the worst for it in dealing with the hands-on bits of performing a migration from .NET Accelerator to WSRP Producer. For others who want to talk about why they did what they did after they did it, or just want to know for themselves, enjoy. A Brief (and edited) History of the WSRP for .NET Technologies (as Relevant to the this Post) Note: This section is for those who are curious about why the migration path is not as simple as many other Oracle technologies. You can skip this section in its entirety and still be just as competent in performing a migration as if you had read it. The currently deployed architecture that was to be migrated and upgraded achieved initial integration between .NET and J2EE over the WSRP protocol through the use of The AquaLogic Interaction .NET Application Accelerator. The .NET Accelerator allowed the applications that were written in ASP.NET and deployed on a Microsoft Internet Information Server (IIS) to interact with a WebLogic Portal application deployed on a WebLogic (J2EE application) Server (both version 9.2, the state of the art at the time of its creation). At the time this architectural decision for the application was made, both the AquaLogic and WebLogic brands were owned by BEA Systems. The AquaLogic brand included products acquired by BEA through the acquisition of Plumtree, whose flagship product was a portal platform available in both J2EE and .NET versions. As part of this dual technology support an adaptor was created to facilitate the use of WSRP as a communication protocol where customers wished to integrate components from both versions of the Plumtree portal. The adapter evolved over several product generations to include a broad array of both standard and proprietary WSRP integration capabilities. Later, BEA Systems was acquired by Oracle. Over the course of several years Oracle has acquired a large number of portal applications and has taken the strategic direction to migrate users of these myriad (and formerly competitive) products to the Oracle WebCenter technology stack. As part of Oracle’s strategic technology roadmap, older portal products are being schedule for end of life, including the portal products that were part of the BEA acquisition. The .NET Accelerator has been modified over a very long period of time with features driven by users of that product and developed under three different vendors (each a direct competitor in the same solution space prior to merger). The Oracle WebCenter WSRP Producer for .NET was introduced much more recently with the key objective to specifically address the needs of the WebCenter customers developing solutions accessible through both J2EE and .NET platforms utilizing the WSRP specifications. The Oracle Product Development Team also provides these insights on the drivers for developing the WSRP Producer: ***************************************** Support for ASP.NET AJAX. Controls using the ASP.NET AJAX script manager do not function properly in the Application Accelerator for .NET. Support 2 way SSL in WLP. This was not possible with the proxy/bridge set up in the existing Application Accelerator for .NET. Allow developers to code portlets (Web Parts) using the .NET framework rather than a proprietary framework. Developers had to use the Application Accelerator for .NET plug-ins to Visual Studio to manage preferences and profile data. This is now replaced with the .NET Framework Personalization (for preferences) and Profile providers. The WSRP Producer for .NET was created as a new way of developing .NET portlets. It was never designed to be an upgrade path for the Application Accelerator for .NET. .NET developers would create new .NET portlets with the WSRP Producer for .NET and leave any existing .NET portlets running in the Application Accelerator for .NET. ***************************************** The advantage to creating a new solution for WSRP is a product that is far easier for Oracle to maintain and support which in turn improves quality, reliability and maintainability for their customers. No changes to J2EE applications consuming the WSRP portlets previously rendered by the.NET Accelerator is required to migrate from the Aqualogic WSRP solution. For some customers using the .NET Accelerator the challenge is adapting their current .NET applications to work with the WSRP Producer (or any other WSRP adapter as they are proprietary by nature). Part of this adaptation is the need to deploy the .NET applications as a child to the WSRP producer web application as root. Differences between .NET Accelerator and WSRP Producer Note: This section is for those who are curious about why the migration is not as pluggable as something such as changing security providers in WebLogic Server. You can skip this section in its entirety and still be just as competent in performing a migration as if you had read it. The basic terminology used to describe the participating applications in a WSRP environment are the same when applied to either the .NET Accelerator or the WSRP Producer: Producer and Consumer. In both cases the .NET application serves as what is referred to as a WSRP environment as the Producer. The difference lies in how the two adapters create the WSRP translation of the .NET application. The .NET Accelerator, as the name implies, is meant to serve as a quick way of adding WSRP capability to a .NET application. As such, at a high level, the .NET Accelerator behaves as a proxy for requests between the .NET application and the WSRP Consumer. A WSRP request is sent from the consumer to the .NET Accelerator, the.NET Accelerator transforms this request into an ASP.NET request, receives the response, then transforms the response into a WSRP response. The .NET Accelerator is deployed as a stand-alone application on IIS. The WSRP Producer is deployed as a parent application on IIS and all ASP.NET modules that will be made available over WSRP are deployed as children of the WSRP Producer application. In this manner, the WSRP Producer acts more as a Request Filter than a proxy in the WSRP transactions between Producer and Consumer. Highly Recommended Enabling Logging Note: You can skip this section now, but you will most likely want to come back to it later, so why not just read it now? Logging is very helpful in tracking down the causes of any anomalies during testing of migrated portlets. To enable the WSRP Producer logging, update the Application_Start method in the Global.asax.cs for your .NET application by adding log4net.Config.XmlConfigurator.Configure(); IIS logs will usually (in a standard configuration) be in a sub folder under C:\WINDOWS\system32\LogFiles\W3SVC. WSRP Producer logs will be found at C:\Oracle\Middleware\WSRPProducerForDotNet\wsrpdefault\Logs\WSRPProducer.log InputTrace.webinfo and OutputTrace.webinfo are located under C:\Oracle\Middleware\WSRPProducerForDotNet\wsrpdefault and can be useful in debugging issues related to markup transformations. Things You Must Do Merge Web.Config Note: If you have been skipping all the sections that you can, now is the time to stop and pay attention J Because the existing .NET application will become a sub-application to the WSRP Producer, you will want to merge required settings from the existing Web.Config to the one in the WSRP Producer. Use the WSRP Producer Master Page The Master Page installed for the WSRP Producer provides common, hiddenform fields and JavaScripts to facilitate portlet instance management and display configuration when the child page is being rendered over WSRP. You add the Master Page by including it in the <@ Page declaration with MasterPageFile="~/portlets/Resources/MasterPages/WSRP.Master" . You then replace: <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" > <HTML> <HEAD> With <asp:Content ID="ContentHead1" ContentPlaceHolderID="wsrphead" Runat="Server"> And </HEAD> <body> <form id="theForm" method="post" runat="server"> With </asp:Content> <asp:Content ID="ContentBody1" ContentPlaceHolderID="Main" Runat="Server"> And finally </form> </body> </HTML> With </asp:Content> In the event you already use Master Pages, adapt your existing Master Pages to be sub masters. See Nested ASP.NET Master Pages for a detailed reference of how to do this. It Happened to Me, It Might Happen to You…Or Not Watch for Use of Session or Request in OnInit In the event the .NET application being modified has pages developed to assume the user has been authenticated in an earlier page request there may be direct or indirect references in the OnInit method to request or session objects that may not have been created yet. This will vary from application to application, so the recommended approach is to test first. If there is an issue with a page running as a WSRP portlet then check for potential references in the OnInit method (including references by methods called within OnInit) to session or request objects. If there are, the simplest solution is to create a new method and then call that method once the necessary object(s) is fully available. I find doing this at the start of the Page_Load method to be the simplest solution. Case Sensitivity .NET languages are not case sensitive, but Java is. This means it is possible to have many variations of SRC= and src= or .JPG and .jpg. The preferred solution is to make these mark up instances all lower case in your .NET application. This will allow the default Rewriter rules in wsrp-producer.xml to work as is. If this is not practical, then make duplicates of any rules where an issue is occurring due to upper or mixed case usage in the .NET application markup and match the case in use with the duplicate rule. For example: <RewriterRule> <LookFor>(href=\"([^\"]+)</LookFor> <ChangeToAbsolute>true</ChangeToAbsolute> <ApplyTo>.axd,.css</ApplyTo> <MakeResource>true</MakeResource> </RewriterRule> May need to be duplicated as: <RewriterRule> <LookFor>(HREF=\"([^\"]+)</LookFor> <ChangeToAbsolute>true</ChangeToAbsolute> <ApplyTo>.axd,.css</ApplyTo> <MakeResource>true</MakeResource> </RewriterRule> While it is possible to write a regular expression that will handle mixed case usage, it would be long and strenous to test and maintain, so the recommendation is to use duplicate rules. Is it Still Relative? Some .NET applications base relative paths with a fixed root location. With the introduction of the WSRP Producer, the root has moved up one level. References to ~/ will need to be updated to ~/portlets and many ../ paths will need another ../ in front. I Can See You But I Can’t Find You This issue was first discovered while debugging modules with code that referenced the form on a page from the code-behind by name and/or id. The initial error presented itself as run-time error that was difficult to interpret over WSRP but seemed clear when run as straight ASP.NET as it indicated that the object with the form name did not exist. Since the form name was no longer valid after implementing the WSRP Master Page, the likely fix seemed to simply update the references in the code. However, as the WSRP Master Page is external to the code, a compile time error resulted: Error      155         The name 'form1' does not exist in the current context                C:\Oracle\Middleware\WSRPProducerForDotNet\wsrpdefault\portlets\legacywebsite\module\Screens \Reporting.aspx.cs                51           52           legacywebsite.module Much hair-pulling research later it was discovered that it was the use of the FindControl method causing the issue. FindControl doesn’t work quite as expected once a Master Page has been introduced as the controls become embedded in controls, require a recursion to find them that is not part of the FindControl method. In code where the page form is referenced by name, there are two steps to the solution. First, the form needs to be referenced in code generically with Page.Form. For example, this: ToggleControl ctrl = new ToggleControl(frmManualEntry, FunctionLibrary.ParseArrayLst(userObj.Roles)); Becomes this: ToggleControl ctrl = new ToggleControl(Page.Form, FunctionLibrary.ParseArrayLst(userObj.Roles)); Generally the form id is referenced in most ASP.NET applications as a path to a control on the form. To reach the control once a MasterPage has been added requires an additional method to recurse through the controls collections within the form and find the control ID. The following method (found at Rick Strahl's Web Log) corrects this very nicely: public static Control FindControlRecursive(Control Root, string Id) { if (Root.ID == Id) return Root; foreach (Control Ctl in Root.Controls) { Control FoundCtl = FindControlRecursive(Ctl, Id); if (FoundCtl != null) return FoundCtl; } return null; } Where the form name is not referenced, simply using the FindControlRecursive method in place of FindControl will be all that is necessary. Following the second part of the example referenced earlier, the method called with Page.Form changes its value extraction code block from this: Label lblErrMsg = (Label)frmRef.FindControl("lblBRMsg" To this: Label lblErrMsg = (Label) FunctionLibrary.FindControlRecursive(frmRef, "lblBRMsg" The Master That Won’t Step Aside In most migrations it is preferable to make as few changes as possible. In one case I ran across an existing Master Page that would not function as a sub-Master Page. While it would probably have been educational to trace down why, the expedient process of updating it to take the place of the WSRP Master Page is the route I took. The changes are highlighted below: … <asp:ContentPlaceHolder ID="wsrphead" runat="server"></asp:ContentPlaceHolder> </head> <body leftMargin="0" topMargin="0"> <form id="TheForm" runat="server"> <input type="hidden" name="key" id="key" value="" /> <input type="hidden" name="formactionurl" id="formactionurl" value="" /> <input type="hidden" name="handle" id="handle" value="" /> <asp:ScriptManager ID="ScriptManager1" runat="server" EnablePartialRendering="true" > </asp:ScriptManager> This approach did not work for all existing Master Pages, but fortunately all of the other existing Master Pages I have run across worked fine as a sub-Master to the WSRP Master Page. Moving On In Enterprise Portals, even after you get everything working, the work is not finished. Next you need to get it where everyone will work with it. Migration Planning Providing that the server where IIS is running is adequately sized, it is possible to run both the .NET Accelerator and the WSRP Producer on the same server during the upgrade process. The upgrade can be performed incrementally, i.e., one portlet at a time, if server administration processes support it. Those processes would include the ability to manage a second producer in the consuming portal and to change over individual portlet instances from one provider to the other. If processes or requirements demand that all portlets be cut over at the same time, it needs to be determined if this cut over should include a new producer, updating all of the portlets in the consumer, or if the WSRP Producer portlet configuration must maintain the naming conventions used by the .NET Accelerator and simply change the WSRP end point configured in the consumer. In some enterprises it may even be necessary to maintain the same WSDL end point, at which point the IIS configuration will be where the updates occur. The downside to such a requirement is that it makes rolling back very difficult, should the need arise. Location, Location, Location Not everyone wants the web application to have the descriptively obvious wsrpdefault location, or needs to create a second WSRP site on the same server. The instructions below are from the product team and, while targeted towards making a second site, will work for creating a site with a different name and then remove the old site. You can also change just the name in IIS. Manually Creating a WSRP Producer Site Instructions (NOTE: all executables used are the same ones used by the installer and “wsrpdev” will be the name of the new instance): 1. Copy C:\Oracle\Middleware\WSRPProducerForDotNet\wsrpdefault to C:\Oracle\Middleware\WSRPProducerForDotNet\wsrpdev. 2. Bring up a command window as an administrator 3. Run C:\Oracle\Middleware\WSRPProducerForDotNet\uninstall_resources\IISAppAccelSiteCreator.exe install WSRPProducers wsrpdev "C:\Oracle\Middleware\WSRPProducerForDotNet\wsrpdev" 8678 2.0.50727 4. Run C:\Oracle\Middleware\WSRPProducerForDotNet\uninstall_resources\PermManage.exe add FileSystem C:\Oracle\Middleware\WSRPProducerForDotNet\wsrpdev "NETWORK SERVICE" 3 1 5. Run C:\Oracle\Middleware\WSRPProducerForDotNet\uninstall_resources\PermManage.exe add FileSystem C:\Oracle\Middleware\WSRPProducerForDotNet\wsrpdev EVERYONE 1 1 6. Open up C:\Oracle\Middleware\WSRPProducerForDotNet\wsdl\1.0\WSRPService.wsdl and replace wsrpdefault with wsrpdev 7. Open up C:\Oracle\Middleware\WSRPProducerForDotNet\wsdl\2.0\WSRPService.wsdl and replace wsrpdefault with wsrpdev Tests: 1. Bring up a browser on the host itself and go to http://localhost:8678/wsrpdev/wsdl/1.0/WSRPService.wsdl and make sure that the URLs in the XML returned include the wsrpdev changes you made in step 6. 2. Bring up a browser on the host itself and see if the default sample comes up: http://localhost:8678/wsrpdev/portlets/ASPNET_AJAX_sample/default.aspx 3. Register the producer in WLP and test the portlet. Changing the Port used by WSRP Producer The pre-configured port for the WSRP Producer is 8678. You can change this port by updating both the IIS configuration and C:\Oracle\Middleware\WSRPProducerForDotNet\[WSRP_APP_NAME]\wsdl\1.0\WSRPService.wsdl. Do You Need to Migrate? Oracle Premier Support ended in November of 2010 for AquaLogic Interaction .NET Application Accelerator 1.x and Extended Support ends in November 2012 (see http://www.oracle.com/us/support/lifetime-support/lifetime-support-software-342730.html for other related dates). This means that integration with products released after November of 2010 is not supported. If having such support is the policy within your enterprise, you do indeed need to migrate. If changes in your enterprise cause your current solution with the .NET Accelerator to no longer function properly, you may need to migrate. Migration is a choice, and if the goals of your enterprise are to take full advantage of newer technologies then migration is certainly one activity you should be planning for.

    Read the article

  • Sending microphone input over Remote Desktop 7.0

    - by Taylor Price
    I am using Remote Desktop 7 (the new version that came out with Windows 7) to control a Windows XP Pro machine. I have selected "Record from this computer" in the Remote Audio settings. When I connect to the machine, go to the control panel, open the sound panel, and go to the audio tab, I find that the default sound playback device is "Microsoft RDP Audio Driver". However, there is no default sound recording device. As expected, my IP phone thinks there is no recording device. If I am sitting in front of the computer with a mic plugged in, it works just fine. Has anybody else been able to get this work appropriately? Is there anything that I have to setup on the XP machine to get this working? Thanks in advance. Edit: As John T pointed out below, you have to be connecting to a Windows 7 Enterprise or Ultimate machine for this to work. I've also found out that Multi-monitor support has the same requirement.

    Read the article

  • ActiveSync devices causing accounts to lockout

    - by Abdullah
    When a user changes his account password for whatever reason (read: expired), and the old password is stored in his mobile device connected through EAS. This will cause his account almost immediately - as it should according to the lockout policy defined in the AD. It was easy to figure out that part. The hard part is keeping it from happening. I looked everywhere. Nothing. Basically there are four parts to the puzzle: the EAS device, the TMG (ISA) server, the EAS protocol and finally the AD. None of them have a way to stop the EAS device from failing to authenticate. So I figured I'll have to come up with a clever workaround. And the only thing I could come up with is to create a group for all EAS users and exclude them from the lockout policy, which obviously defeats the whole purpose of the policy, or to educate the users to update their devices with the new passwords, which is impossible. The question: Can you think of any other way to prevent EAS from locking out the accounts? Environment: Mostly iOS devices all through EAS. TMG 2010. Exchange 2007. AD 2008 R2.

    Read the article

  • iSCSI errors continue after removing inaccessible target portal

    - by Ansgar Wiechers
    By mistake I entered an iSCSI target portal address in the iSCSI Initiator on one of our virtual servers that does not have an address in the network range used for iSCSI. This caused the following errors/warnings to appear in the eventlog: Log Name: System Source: MSiSCSI Event ID: 113 Level: Warning Description: iSCSI discovery via SendTargets failed with error code 0xefff0003 to target portal *192.168.23.42 0003260 Root\ISCSIPRT\0000_0 . Log Name: System Source: iScsiPrt Event ID: 1 Level: Error Description: Initiator failed to connect to the target. Target IP address and TCP Port number are given in dump data. Log Name: System Source: iScsiPrt Event ID: 70 Level: Error Description: Error occurred when processing iSCSI logon request. The request was not retried. Error status is given in the dump data. So far that's expected beahvior, so I removed the portal from the iSCSI Initiator as described in MSKB 976072. However, the errors/warnings keep appearing every hour, even though neither iSCSI Initiator GUI nor iscscli show any portals: C:\>iscsicli ListTargetPortals Microsoft iSCSI Initiator Version 6.1 Build 7601 The operation completed successfully. The problem persists after rebooting the server. Uninstalling the Microsoft iSCSI Initiator device via devmgmt.msc as well as changing the Initiator parameters like this: [HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}] "MaxPendingRequests"=dword:00000001 "MaxConnectionRetries"=dword:00000001 "MaxRequestHoldTime"=dword:00000005 didn't help either. Each change was followed by a reboot. Disabling the device does prevent the errors/warnings from re-appearing, of course, but I'd rather not have to resort to this. How can I prevent those errors and warnings from appearing (short of disabling the initiator device or re-installing the server)? What am I missing? Environment: The virtual machine runs on a Hyper-V cluster managed by SCVMM 2012. Hosts and guests run Windows Server 2008 R2 SP1. The physical machines are Dell PowerEdge M710HD blades.

    Read the article

  • Iomega eGo Encrypt Plus Encrypted Partition not mounting properly says "local disk"

    - by mosiac
    I'm working with an Iomega eGo 500gb Encrypt Plus portable drive. When I first set it up and installed the software and set a user password everything worked fine. The partition labeled "IomegaHDD" mounted properly and I could access the free space. Then I changed the ADMIN password which required me to lockout the device, wait 60 seconds, and then login to the Admin section and change the password, lockout the device again, wait 60 seconds, and then log back in with my user password. When I did that it of course unmounted the IomegaHDD partition to secure it, when it remounts it, it only shows up as "local disk" now and will not remount properly. I had not removed the cable while doing any of this. I have since tried unplugging and plugging back in to login to the drove but that has not worked. I'm wondering if I should remove every instance of "generic usb hub" from device manager and wait for it to re-add itself, or move it to a new set of USB ports temporarily to seee if that helps. Any ideas?

    Read the article

  • Looking for USB Network Attached Storage (NAS) Adapter that supports multiple drives, NTFS/FAT32 fil

    - by braveterry
    I'm looking for a NAS Adapter that supports attaching multiple USB devices to the network. Here's what I'd like to see in a NAS adapter: Under $100.00. Support for multiple devices. This can be through a USB hub or through multiple USB connectors on the device itself. Bittorrent support would be nice, but this isn't a deal-breaker. Filesystem support for at least NTFS or FAT32. I'd prefer to not have to reformat to use the device, but this is also not a deal-breaker. Here is what I am NOT looking for: I'm NOT looking for a NAS enclosure. I already have a couple of spare external USB drives that I'd like to use. I'm NOT looking for a networked USB hub like the one mentioned here. Network USB hubs only allow access to a drive from one PC at a time. I'm NOT looking for a wireless router with a NAS built in. I already have a wireless router, and I'd rather not go through the hassle of replacing it if possible. What I've looked at so far PogoPlug: This supports multiple devices via a USB hub, but there's not Bittorrent support. It's $99.00, so I may end up going with this and hope that they patch in Bittorrent support later. Addonics NAS Adapter: This supports only one device per adapter, so it's a non-starter. SimpleNET NAS Head USB 2.0 Portable Dongle: I'm not 100% sure this supports multiple devices. Plus there doesn't seem to be any Bittorrent support. I'll try to update this post as I explore other devices.

    Read the article

  • Cisco ASA Act as a Hardware Security Module?

    - by Derek
    Hello, We have a partner that is requiring us to get a HSM for a web application that we host for them. This is something new for us, we've always installed our SSL certificates on our web servers and never needed a hardware device. We currently have 2 Cisco ASA 5510 firewalls in an active/standby configuration. Both ASAs have a ASA-SSM-10 security module installed in them. The web application is a standard HTTPS webpage with no authentication required. I was wondering if we could use our Cisco ASAs to meet this requirement or if we'll have to buy another device. I was doing some searching and read about Cisco's clientless webvpn feature. It sounds like it might work, but I'm not sure. We basically want the ASA to handle the SSL and proxy the connection to our web servers. We do not want to prompt for a username or password to connect or show any portals, just display the web page. If the ASA cannot do this, does any one have any recommendations for network attached hardware security modules? We are using VMware vCenter, so we'd rather have an external device attached to the network, rather than buying HSM cards for every ESXi host. Thanks, Derek

    Read the article

  • Why can't I reconnect to my Philips SHB9000 bluetooth headset?

    - by Thomas Eyde
    This is so annoying. When I connected my Philips SHB9000 bluetooth to my Windows 7 (64 bit) for the very first time, it worked well. I had to manually change the default playback device, but otherwise it worked. Then, when I start up my computer from standby, it's nearly random when I can reconnect or not. My last option is to remove the bluetooth device and reconnect it. But now, even that doesn't work. The sad thing is, this used to work better on Windows 7 beta. Windows Update has a new driver which fails to install. Searching for this driver yields nothing. I thought all vendors had an official site for their drivers? Well, Philips seems to have none. If there is no answer to this problem, my advice is to NOT buy this headset. It's good looking, the sound is nice, but what need do we have from that if we can't use the bloody device?

    Read the article

  • Cisco Spam Blocker, Iron Port, Lotus Domino, Integration Help

    - by NickToyota
    Hi serverfault universe, I work for a medium sized (roughly 200 user) company. We are attempting to intagrate our new Cisco Spam Video Blocker (ironport) device into our network so that it acts as an incoming filter then passes it off to our Lotus domino mail server. And also vise versa. The way our network is setup currently has an mx record pointing to our Domino mail SMTP incoming server which is currently setup to be an inbound gateway and filter (using symantec domino mail software). We want to replace the inbound gateway with the ironport. Our company has also invested in a pool of external IP addresses which I believe has been currently assigned to our web, email, servers. What would the proper course of action be to successfully integrate the device be? Mx record change? Replace the domino gateway completely with the ironport? We attempted to set the ironport device to the external IP of what our mx record is pointing to without much success. Any help on proper setup would be greatly appreciated.

    Read the article

  • Static routing on a TP-Link TL-WR1043ND

    - by igor
    My home network setup looks like this: Both routers are TP-Link TL-WR1043ND routers. The basement router handles all devices in the house that are connected via cable, handing out addresses for the 10.89.49.0/24 network via DHCP. Wireless doesn’t really work from the basement, as the signal is too weak, so I have disabled it. To do WiFi, I have added a second (identical) router downstairs. On the WAN side it is assigned the 10.89.49.101 IP address from the basement router, and on its LAN it provides the 10.89.7.0/24 network. Basic internet access works flawlessly from any device this way. I am now facing the problem that I am not able to communicate (e.g. SSH) between all devices, wired or wireless. I am able to connect from a wireless device to a wired device, for example SSH-ing from 10.89.7.X to 10.89.49.Y, but it doesn’t work the other way round—despite the fact that I have added a static route to the basement router: Does anybody have any idea on how to solve it? Both routers have already been upgraded to use the most recent firmware from TP-Link.com (Build 110429), to no avail. Errata: I would like to stick with the official firmware, switching to something like DD-WRT or OpenWrt only as a last resort.

    Read the article

  • Windows Audio Issue

    - by Nikki
    This one is driving me nuts. Hoping someone can shed some light. I'm running windows 7 using onboard audio. It's been fine for over 2 years but lately there's a problem every time I play audio. I hear a small soft burst of static and the volume turns itself down from 50% to 23%. Once at 23%, it plays fine. No related events logged in viewer. No reported problems with the device. Different headphones, same problem. I played around with audio settings for hours but the problem persists. EDIT: ok more info: Motherboard: ECS G31T-M LGA775 System info displays this: Name High Definition Audio Device Manufacturer Microsoft Status OK PNP Device ID HDAUDIO\FUNC_01&VEN_1106&DEV_E721&SUBSYS_10192683&REV_1001\4&3D4E739&0&0001 Driver c:\windows\system32\drivers\hdaudio.sys (6.1.7600.16385, 297.00 KB (304,128 bytes), 14/07/2009 9:51 AM) I'll keep adding info as I find it. The question I want resolved is; Is it faulty hardware? If so, I can buy a sound card. I can't imagine software is responsible since I haven't installed anything new for weeks. Virus scans are clear as well. The static burst is irritating to say the least. Tried 2 different headphones and separate speakers. Same problem. I know it's not an easy problem but I was hoping someone had encountered the same thing.

    Read the article

  • IPMI not fucntioning with Network Bonding

    - by muhammed sameer
    Hey, I am having problems with running IPMI on my servers that have network bonding enabled. Platform: CentOS release 5.3 (Final) Kernel: 2.6.18-92.el5 64bit Dell PowerEdge 1950 Ethernet controller: Broadcom Corporation NetXtreme II BCM5708 Gigabit Ethernet I have bonded the interface eth0 and eth1 as active passive, with eth0 as the active interface, below is conf description from /proc Bonding Mode: fault-tolerance (active-backup) Primary Slave: eth0 Currently Active Slave: eth0 MII Status: up MII Polling Interval (ms): 30 Up Delay (ms): 0 Down Delay (ms): 0 Slave Interface: eth0 MII Status: up Link Failure Count: 0 Permanent HW addr: 00:22:19:56:b9:cd Slave Interface: eth1 MII Status: up Link Failure Count: 0 Permanent HW addr: 00:22:19:56:b9:cf My IPMI device is as follows IPMI Device Information Interface Type: KCS (Keyboard Control Style) Specification Version: 2.0 I2C Slave Address: 0x10 NV Storage Device: Not Present Base Address: 0x0000000000000CA8 (I/O) Register Spacing: 32-bit Boundaries I Have used openIPMI as well as freeipmi both to control the chassis via the IPMI card, but on servers which have bonding enabled, the command times out, below is the full run of the command with debug info. ipmi_lan_send_cmd:opened=[0], open=[4482848] IPMI LAN host 70.87.28.115 port 623 Sending IPMI/RMCP presence ping packet ipmi_lan_send_cmd:opened=[1], open=[4482848] No response from remote controller Get Auth Capabilities command failed ipmi_lan_send_cmd:opened=[1], open=[4482848] No response from remote controller Get Auth Capabilities command failed Error: Unable to establish LAN session Failed to open LAN interface Unable to get Chassis Power Status On the other hand I configured IPMI on a box with the same specs as mentioned above without bonding and IPMI works perfectly. Has anyone faced this problem with IPMI + Bonding ? I would be thankful is someone helps circumvent this issue. Muhammed Sameer

    Read the article

  • frequent "SNMP error" with Cacti

    - by nn4l
    When adding new devices to my Cacti instance, I get frequent "SNMP error" messages in the device screen. But the error is not consistent, not even for the same device. Here's what I already have checked: Sometimes a device shows that "SNMP error" message even when it did not had that error an hour before, and vice versa. I tried this with several different Cacti releases, installed on different OS (Debian squeeze: 0.8.7g-1+squeeze1, Debian Sid: 0.8.7i-3, CentOS 6.0: 0.8.7i-2.el6) tried both from a local (192.168.1.xy) network and from a different data center so I don't think it is a network problem reinstalled the Cacti database, rerun the scripts to install my devices. Now different devices have that error when executing a snmpwalk or snmpgetnext command from the command line, it is always successful increasing the timeout to 20000 (20 seconds) and the retry count to 10 does not make a difference The cacti.log says: 04/14/2012 02:10:19 PM - CMDPHP: Poller[0] WARNING: SNMP GetNext Timeout for Host:'s0026.mydomain.de', and OID:'.1.3.6.1.2.1.1.3.0' 04/14/2012 02:10:20 PM - CMDPHP: Poller[0] WARNING: SNMP GetNext Timeout for Host:'s0026.mydomain.de', and OID:'.1.3' However, when executing snmpget or snmpget with that from the command line a proper response is returned immediately.

    Read the article

  • What's up with stat on MacOSX/Darwin? Or filesystems without names...

    - by Charles Stewart
    In response to a question I asked on SO, Give the mount point of a path, one respondant suggested using stat to get the device name associated with the volume of a given path. This works nicely on Linux, but gives crazy results on MacOSX 10.4. For my system, df and mount give: cas cas$ df Filesystem 512-blocks Used Avail Capacity Mounted on /dev/disk0s3 58342896 49924456 7906440 86% / devfs 194 194 0 100% /dev fdesc 2 2 0 100% /dev <volfs> 1024 1024 0 100% /.vol automount -nsl [166] 0 0 0 100% /Network automount -fstab [170] 0 0 0 100% /automount/Servers automount -static [170] 0 0 0 100% /automount/static /dev/disk2s1 163577856 23225520 140352336 14% /Volumes/Snapshot /dev/disk2s2 409404102 5745938 383187960 1% /Volumes/Sparse cas cas$ mount /dev/disk0s3 on / (local, journaled) devfs on /dev (local) fdesc on /dev (union) <volfs> on /.vol automount -nsl [166] on /Network (automounted) automount -fstab [170] on /automount/Servers (automounted) automount -static [170] on /automount/static (automounted) /dev/disk2s1 on /Volumes/Snapshot (local, nodev, nosuid, journaled) /dev/disk2s2 on /Volumes/Sparse (asynchronous, local, nodev, nosuid) Trying to get the devices from the mount points, though: cas cas$ df | grep -e/ | awk '{print $NF}' | while read line; do echo $line $(stat -f"%Sdr" $line); done / disk0s3r /dev ???r /dev ???r /.vol ???r /Network ???r /automount/Servers ???r /automount/static ???r /Volumes/Snapshot disk2s1r /Volumes/Sparse disk2s2r Here, I'm feeding each of the mount points scraped from df to stat, outputting the results of the "%Sdr" format string, which is supposed to be the device name: Cf. stat(1) man page: The special output specifier S may be used to indicate that the output, if applicable, should be in string format. May be used in combination with: ... dr Display actual device name. What's going on? Is it a bug in stat, or some Darwin VFS weirdness? Postscript Per Andrew McGregor, try passing "%Sd" to stat for more weirdness. It lists some apparently arbitrary subset of files from CWD...

    Read the article

< Previous Page | 353 354 355 356 357 358 359 360 361 362 363 364  | Next Page >