Search Results

Search found 57569 results on 2303 pages for 'windows scheduler'.

Page 437/2303 | < Previous Page | 433 434 435 436 437 438 439 440 441 442 443 444  | Next Page >

  • Incorporating the Windows 7 onscreen keyboard into a WPF app

    - by mmr
    Windows 7 has a really nice onscreen keyboard program/control for touchscreens. I have a touchscreen app that was originally written for, and will be deployed on, XP. Is it possible to incorporate this keyboard directly into my app, rather than me using a custom control? I can find no programmatic information about it, so any links would be very helpful. Specifically, I'd need: To be able to use the keyboard on an XP machine that will have .NET 3.5 sp1 installed on it. To be able to hide the native keyboard on Windows 7, because I've already incorporated the touchscreen keyboard in my UI and so I don't need another one cluttering up the UI. This native keyboard has two attractive aspects to it. First off, it's automatically localized to the customer's language (though the rest of the app will need modification), and second off, it doesn't seem to suffer from 'touch lag' as the OS tries to figure out whether or not I'm doing a gesture, because I'm clearly typing on a keyboard. The app is WPF based, which should mean easy integration with Windows 7 based controls. EDIT: I'd really like the XP thing, but it's not a requirement. The ability to use the keyboard in Win7, though, seems like it should be possible and even the right way to do it.

    Read the article

  • VB6 Manifest not working on Windows 7

    - by Matt
    I have created a manifest file for a VB6 application that is running on Windows 7 (not for any visual style changes, just to make sure it accesses the common registry and not a virtualised one) The exe name is Capadm40.exe, the manifest is named Capadm40.exe.manifest and contains the following: <?xml version="1.0" encoding="UTF-8" standalone="yes"?> <assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0"> <assemblyIdentity version="1.0.0.0" processorArchitecture="X86" name="CompanyName.Capadm40" type="win32"/> <description>Administers the System</description> <!-- Identify the application security requirements. --> <trustInfo xmlns="urn:schemas-microsoft-com:asm.v3"> <security> <requestedPrivileges> <requestedExecutionLevel level="asInvoker" uiAccess="false"/> </requestedPrivileges> </security> </trustInfo> </assembly> However, this doesn't seem to make any difference. ie the application is still using the virtualised registry hive. What is also strange is the after I unticked the 'Run this program as an administrator' option in the properties of the application exe, windows still shows a shield on the application icon, leading my to think this is some issue with my windows installation rather than a fault with the manifest. Any ideas?

    Read the article

  • Windows-Mobile Directshow: Specifying bitrate/quality of a WMV video capture

    - by Landstander
    Hi- I'm stumped on this, and I'm really hoping someone could point me in the right direction. I'm currently capturing video in Windows Mobile and encoding it using the WMV 9 DMO (CLSID_CWMV9EncMediaObject). That all works well enough, but the output video's bitrate is too high, resulting in a video file that's much too large for my needs. Ultimately, my goal is to mimic the video settings that Microsoft's Camera Capture Dialog outputs in the "messaging" quality mode (64kbps) from my C++ code. Currently, my code's outputting a WMV file with a bitrate of 352kbps. The only example I could find of specifying the capture bitrate with a WMV9 DMO was this. The idea in that code was basically to use a propertybag to write a bitrate to a property of the DMO. Update: In windows mobile, the closest codec property I can find that seems to equate to the bitrate is "g_wszWMVCVBRQuality". Microsoft's documentation of this property is extremely confusing to me: It basically seems to say that a higher number equates to a higher quality, but it gives absolutely no explanation of the specifics for each number. When I attempt to set this property to value like "1" via a propertybag for the WMV9 DMO, I run into a -2147467259 (unknown) error. To summarize: What is the basic strategy to specify the bitrate/quality of a video being captured via directshow (wmv9) on a windows mobile platform? I've heard (or wondered about) the following methods: Use the propertybag to change the encoder DMO's property that corresponds to bitrate/quality (currently failing) Create your own custom transcoder/encoder to specify it. This seems unnecessary since the WMV encoder works well enough- it's just at too high a bitrate. The VIDEOINFOHEADER has a bitrate property, but I suspect that specifying new settings here will do nothing to alter the actual encoding process since I wouldn't think file attributes would come into play until after the encoding. Any suggestions? PS: I would post specific source code, but at this point it may confuse more than it helps since I'm floundering so much on how to do this. At this point, I'm just trying to validate the general strategy. THANKS!

    Read the article

  • Windows 7 64 Bit - ODBC32 - Legacy App Problem

    - by Arturo Caballero
    Good day StackOverFlowlers, I´m a little stuck (really stuck) with an issue with a legacy application on my organization. I have a Windows 7 Enterprise 64 Bit machine, Access 2000 Installed and the Legacy App (Is built with something like VB but older) The App uses System ODBC in order to connect to a SQL 2000 DataBase on a Remote Server. I created the ODCB using C:\Windows\SysWOW64\odbcad32.exe app in order to create a System DSN. I did not use the Windows 7 because it is not visible to the Legacy App. I tested the ODBC connection with Access and worked ok, I can access the remote database. Then I run the legacy App as Administrator and the App can see the ODBC, but I´m getting errors on credential validation and I´m getting this error: DIAG [08001] [Microsoft][ODBC SQL Server Driver][Multi-Protocol]SQL Server does not exist or access denied. (17) DIAG [01000] [Microsoft][ODBC SQL Server Driver][Multi-Protocol]ConnectionOpen (Connect()). (53) DIAG [IM006] [Microsoft][ODBC Driver Manager] Driver's SQLSetConnectAttr failed (0) I use Trusted Connection on the ODBC in order to validate the user by Domain Controller. I think that the credentials are not being sent by the Legacy App to the ODBC, or something like that. I don´t have the source code of the Legacy App in order to debug the connection. Also, I turned off the Firewall. Any ideas?? Thanks in advance!

    Read the article

  • C# Windows Service

    - by Goober
    Scenario I've created a windows service, but whenever I start it, it stops immediately. The service was concieved from a console application that used to subscribe to an event and watch processes on a server. If anything happened to process (i.e. It was killed), then the event would trigger the process to be restarted. The reason I'm telling you this is because the original code used to look like this: Original Console App Code: static void Main(string[] args) { StartProcess sp = new StartProcess(); //Note the readline that means the application sits here waiting for an event! Console.ReadLine(); } Now that this code has been turned into a Windows Service, it is essentially EXACTLY THE SAME. However, the service does not sit there waiting, even with the readline, it just ends..... New Windows Service Code: protected override void OnStart(string[] args) { ProcessMonitor pm = new ProcessMonitor(); Console.ReadLine(); } Thoughts Since the functionality is entirely encapsulated within this single class (It quite literally starts, sets up some events and waits) - How can I get the service to actually sit there and just wait? It seems to be ignoring the readline. However this works perfectly as a console application, it is just far more convenient to have it as a service.

    Read the article

  • Forking in PHP on Windows

    - by Doug Kavendek
    We are running PHP on a Windows server (a source of many problems indeed, but migrating is not an option currently). There are a few points where a user-initiated action will need to kick off a few things that take a while and about which the user doesn't need to know if they succeed or fail, such as sending off an email or making sure some third-party accounts are updated. If I could just fork with pcntl_fork(), this would be very simple, but the PCNTL functions are not available in Windows. It seems the closest I can get is to do something of this nature: exec( 'php-cgi.exe somescript.php' ); However, this would be far more complicated. The actions I need to kick off rely on a lot of context that already will exist in the running process; to use the above example, I'd need to figure out the essential data and supply it to the new script in some way. If I could fork, it'd just be a matter of letting the parent process return early, leaving the child to work on a few more things. I've found a few people talking about their own work in getting various PCNTL functions compiled on Windows, but none seemed to have anything available (broken links, etc). Despite this question having practically the same name as mine, it seems the problem was more execution timeout than needing to fork. So, is my best option to just refactor a bit to deal with calling php-cgi, or are there other options? Edit: It seems exec() won't work for this, at least not without me figuring some other aspect of it, as it waits until the call returns. I figured I could use START, sort of like exec( 'start php-cgi.exe somescript.php' );, but it still waits until the other script finishes.

    Read the article

  • WCF Security in a Windows Service

    - by Alphonso
    I have a WCF service which can run as Console App and a Windows Service. I have recently copied the console app up to a W2K3 server with the following security settings: <wsHttpBinding> <binding name="ServiceBinding_Security" transactionFlow="true" > <security mode="TransportWithMessageCredential" > <message clientCredentialType="UserName" /> </security> </binding> </wsHttpBinding> <serviceCredentials> <userNameAuthentication userNamePasswordValidationMode="Custom" customUserNamePasswordValidatorType="Common.CustomUserNameValidator, Common" /> </serviceCredentials> Security works fine with no problems. I have exactly the same code, but running in a windows service and I get the following error when I try to call any of the methods from a client: System.ServiceModel.Security.MessageSecurityException was unhandled Message="An unsecured or incorrectly secured fault was received from the other party. See the inner FaultException for the fault code and detail." Source="mscorlib" StackTrace: Server stack trace: at System.ServiceModel.Channels.SecurityChannelFactory`1.SecurityRequestChannel.ProcessReply(Message reply, SecurityProtocolCorrelationState correlationState, TimeSpan timeout) ...... (lots of stacktrace info - not very useful) InnerException: System.ServiceModel.FaultException Message="An error occurred when verifying security for the message." The exception tells me nothing. I'm assuming that it has something to do with acces to system resources from the Windows Service. I've tried running it under the same account as the console app, but no luck. Does anyone have any ideas?

    Read the article

  • Windows Media Encoder object not created in ASP.NET on MS Server 2003 64 bit

    - by Ron
    Hello, I created (and used) a Windows Media Encoder object in Microsoft Visual C# 2008 Express Edition on MS Server 2003 64 bit. This worked fine. However, when I attempted to create the equivalent Windows Media Encoder object using Microsoft Visual Web Developer 2008 on MS Server 2003 64 bit, the following exception was thrown: "Retrieving the COM class factory for component with CLSID {632B606A-BBC6-11D2-A329-006097C4E476} failed due to the following error: 80040154." It cannot be that the component isn’t registered, because both have a reference to the same WMEncEng.dll file. The Microsoft Visual Web Developer 2008 code also worked fine on XP 32 bit. Could it be a problem with permissions? Regardless, anyone have any ideas why this problem is occurring and, more importantly, how to resolve it? Thank you. Here are the two code snippets from MS Server 2003 64 bit: Microsoft Visual Web Developer 2008 (did not work): using System; using WMEncoderLib; namespace TestWMEnc { public partial class _Default : System.Web.UI.Page { protected void Page_Load(object sender, EventArgs e) { try { WMEncoder encoder = new WMEncoder(); //exception thrown // ... } catch (Exception err) { string exception = err.Message; } } } } Microsoft Visual C# 2008 Express Edition (worked fine): using System; using System.Windows.Forms; using WMEncoderLib; namespace testWMEncoder { public partial class Form1 : Form { public Form1() { InitializeComponent(); } private void button1_Click(object sender, EventArgs e) { try { WMEncoder encoder = new WMEncoder(); // ... } catch (Exception err) { string exception = err.Message; } } } }

    Read the article

  • Silently catch windows error popups when calling System.load() in java

    - by Marcelo Morales
    I have a Java Swing application, which needs to load some native libraries in windows. The problem is that the client could have different versions of those libraries. In one recent version, either the names changed or the order on which the libraries must be loaded changed. To keep up, we iterated over all possible library names but some fail to load (due to it's nonexistence or because another must be loaded previously). This idea works on older Windows but on latter ones it shows a error popup. I saw on question 4058303 (Silently catch windows error popups when calling LoadLibrary) that I need to call SetErrorMode but I am not sure how to call SetErrorMode from jna. I tried to follow the idea from question 11038595 but I am not sure how to proceed. public interface CKernel32 extends Kernel32 { CKernel32 INSTANCE = (CKernel32) Native.loadLibrary("kernel32", CKernel32.class); // TODO: HELP: HOW define the SetErrorMode function } How do I define (from the SetErrorMode documentation): UINT WINAPI SetErrorMode( _In_ UINT uMode ); in the line marked as TODO: HELP:? Thanks in advance

    Read the article

  • Windows 7 theme for WPF?

    - by DanM
    Is there any way to make a WPF app look like it's running on Windows 7 even if it's running on XP? I'm looking for some kind of theme I can just paste in. I'm aware of the themes project on Codeplex (http://www.codeplex.com/wpfthemes), but it lacks support for DataGrid, which is something I critically need. I was thinking maybe the Windows 7 theme would just be an easy port, or exists in some file somewhere already. Any information you have (even if it's bad news) would be much appreciated. Update Using @Lars Truijens idea, I was able to get the Windows 7 look for the major controls, but unfortunately it did not work for the WPF Toolkit DataGrid control, which I need. DataGrid looks like this with Aero theme DataGrid should look like this So, I'm still looking for a solution to this problem if anyone has any ideas. Maybe someone has built an extension to the Aero theme that covers the WPF toolkit controls? Again, any information you have is much appreciated. Update 2 - Problem solved! To get the Aero theme to work with WPF Toolkit controls, you just need to add a second Aero dictionary, so your App.xaml should now look like this. <Application.Resources> ... <ResourceDictionary> <ResourceDictionary.MergedDictionaries> <ResourceDictionary Source="/PresentationFramework.Aero;component/themes/Aero.NormalColor.xaml" /> <ResourceDictionary Source="pack://application:,,,/WPFToolkit;component/Themes/Aero.NormalColor.xaml" /> ... </ResourceDictionary.MergedDictionaries> </ResourceDictionary> </Application.Resources> Also, I would recommend turning the gridlines off in your DataGrid controls (because they look horrible): <DataGrid GridLinesVisibility="None" ...>

    Read the article

  • PHP gettext on Windows

    - by Axsuul
    There's some tutorials out there for gettext (w/ Poedit)... unfortunately, it's mostly for a UNIX environment. And even more unfortunate is that I am running my WAMP server on Windows XP (but I am developing for a UNIX environment) and none of the tutorials can get gettext working properly for me. From the man page (http://us3.php.net/manual/en/book.gettext.php), it appears that it's a different process on a Windows environment. I've tried out some of the solutions in the comments but I still can't get it to work! Please, I've spent many hours on this, hopefully someone can point me in the right direction to get this thing to work! (and I'm sure there are others out there who share my frustration). So far with my setup, I'm only getting output "Hello World!" whereas I should be getting the translated string. Here is my setup/code so far: <?php // test.php if (!defined('LC_MESSAGES')) { define('LC_MESSAGES', 6); } $locale = "deu_DEU"; // apparently the locales are different on a WINDOWS platform putenv("LC_ALL=$locale"); setlocale(LC_ALL, $locale); bindtextdomain("greetings", ".\locale"); textdomain("greetings"); echo _("Hello World"); ?> Folder structure root: C:\Program Files\WampServer 2\www test.php: C:\Program Files\WampServer 2\www\site .po: C:\Program Files\WampServer 2\www\site\locale\deu_DEU\LC_MESSAGES\greetings.po .mo: C:\Program Files\WampServer 2\www\site\locale\deu_DEU\LC_MESSAGES\greetings.mo Please advise! Thanks for your time :)

    Read the article

  • Reusing Windows Picture and Fax Viewer process to load a new image from FileSystemWatcher

    - by Cory Larson
    So for an idea for my birthday party I'm setting up a photo booth. I've got software to remotely control the camera and all that, but I need to write a little application to monitor the folder where the pictures get saved and display them. Here's what I've got so far. The issue is that I don't want to launch a new Windows Photo Viewer process every time the FileSystemWatcher sees a new file, I just want to load the latest image into the current instance of the Windows Photo Viewer (or start a new one if one isn't running). class Program { static void Main(string[] args) { new Program().StartWatching(); } public void StartWatching() { FileSystemWatcher incoming = new FileSystemWatcher(); incoming.Path = @"G:\TempPhotos\"; incoming.NotifyFilter = NotifyFilters.LastWrite | NotifyFilters.FileName; incoming.Filter = "*.jpg"; incoming.Created += new FileSystemEventHandler(ShowImage); incoming.EnableRaisingEvents = true; Console.WriteLine("Press \'q\' to quit."); while (Console.Read() != 'q') ; } private void ShowImage(object source, FileSystemEventArgs e) { string s1 = Environment.ExpandEnvironmentVariables("%windir%\\system32\\rundll32.exe "); string s2 = Environment.ExpandEnvironmentVariables("%windir%\\system32\\shimgvw.dll,ImageView_Fullscreen " + e.FullPath); Process.Start(s1, s2); Console.WriteLine("{0} : Image \"{0}\" at {1:t}.", e.ChangeType, e.FullPath, DateTime.Now); } } If you don't have a tried and true solution, a simple push in the right direction would be just as valuable. And FYI, this will be running on a 64-bit Windows 7 machine. Thanks!

    Read the article

  • Directly accessing the modem in Windows Mobile

    - by kigurai
    For some reasons I need to be able to access the internal modem of a Windows Mobile smartphone (a HTC s740 with WM version 6.1). What I want is to be able to access it like it was a serial port in order to give AT-commands. I have code that uses the TAPI Line interface and lineGetID() to get a "handle" on which I shuld be able to do ReadFile()/WriteFile(). Sadly I have not gotten it to work. What I do currently is: Initialize TAPI with lineInitializeEx() Open the Line with lineOpen() Iterate through each available device and get info. Currently I am selecting the "UNIMODEM"/"Hayes compatible on COM1" device. But maybe I should choose the "TAPI cellular service"/"Cellular Line" instead? I have tried the "Cellular Line" device with the same result. Use lineGetID() on the selected device to get a handle. Do WriteFile("AT\r") and then directly do a ReadFile(), which should give me a "OK" back if it really was the modem I accessed. Realize that it doesn't work and get annoyed... But this has so far been a no-go. Does anyone have any idea on how to do it? I am doing this in Native WIN32 C++ on Windows Mobile 6 SDK. UPDATE: I have so far managed to get a data connection between two phones using RIL, which gives me a serial port handle to write and read from. BUT, I still would like to be able to interact directly with the modem to send AT-commands. So, the bounty I am starting only concerns getting direct access to the modem in order to give AT-commands. My investigations so far indicates that this was possible in previous versions of Windows Mobile (by opening COM2 and/or COM9 and slaying RIL, or something like that) but I have not yet seen code which works on WM6.

    Read the article

  • PocketPC c++ windows message processing recursion problem

    - by user197350
    Hello, I am having a problem in a large scale application that seems related to windows messaging on the Pocket PC. What I have is a PocketPC application written in c++. It has only one standard message loop. while (GetMessage (&msg, NULL, 0, 0)) { { TranslateMessage (&msg); DispatchMessage (&msg); } } We also have standard dlgProc's. In the switch of the dlgProc, we will call a proprietary 3rd party API. This API uses a socket connection to communicate with another process. The problem I am seeing is this: whenever two of the same messages come in quickly (from the user clicking the screen twice too fast and shouldn't be) it seems as though recursion is created. Windows begins processing the first message, gets the api into a thread safe state, and then jumps to process the next (identical ui) message. Well since the second message also makes the API call, the call fails because it is locked. Because of the design of this legacy system, the API will be locked until the recursion comes back out (which also is triggered by the user; so it could be locked the entire working day). I am struggling to figure out exactly why this is happening and what I can do about it. Is this because windows recognizes the socket communication will take time and preempts it? Is there a way I can force this API call to complete before preemption? Is there a way I can slow down the message processing or re-queue the message to ensure the first will execute (capturing it and doing a PostMessage back to itself didnt work). We don't want to lock the ui down while the first call completes. Any insight is greatly appreciated! Thanks!!

    Read the article

  • Best terminal environment for Cygwin/Windows?

    - by Anders Sandvig
    Today I run Cygwin with rxvt using the following startup line: rxvt -bg black -sl 8192 -fg white -sr -g 150x56 -fn "Fixedsys" -e /usr/bin/bash --login -i This gives me a resizeable native Windows window which is much better than the standard "DOS box" the default cygwin.bat provides. However, the current configuration does have a couple of issues: I am not able to enter non-ASCII characters into the terminal window (i.e. æ, ø, å and Æ, Ø, Å, which I use semi-frequently. In fact, the terminal will not even accept them when I paste them into the window. If I paste a string like "bølle" (Norwegian for "bulley"), all I get is "blle". I am not able to render UTF-8 character, they only show as ?, even if they are supported by the font (i.e. when rendering the same characters in ISO-8859-1 they show just fine.). I am running English Windows Vista with locale and keyboard layout set to Norwegian (ISO-8859-1 character set?), but I've had the exact same issue on Windows 2000 and XP. Anyone knows how to fix this (i.e. a better way to configure rxvt)? Apart from the issues mentioned above, I'm very happy with rxvt, so if I find a way to resolve them I'd like to continue using it. However, if the issues are not (easily) solvable, are the any other good terminal solutions for Cygwin? Update The solution provided by Andy and Mattias (editing the .inputrc file) did solve the input problem, but output rendering is still an issue. Output is fine when I render in ISO-8859-1, but when using UTF-8 I only get ? for non-ASCII characters. This behavior is consistent between rxvt, urxvt (under Cygwin XFree X Server), mintty and PuttyCyg. Is there a similar configuration file where output encoding can be set (i.e. the equivalent of setting output locale on a Linux system)?

    Read the article

  • Capturing window image in windows server 2008

    - by Sergey Osypchuk
    I am capturing output of windows program using following function: public static Bitmap Get(IntPtr hWnd, int X1, int Y1, int width, int height) { WINDOWINFO winInfo = new WINDOWINFO(); bool ret = GetWindowInfo(hWnd, ref winInfo); if (!ret) { return null; } int curheight = height; if (curheight <= 0 || curheight > winInfo.rcWindow.Height) curheight = winInfo.rcWindow.Height; int curwidth = width; if (curwidth <= 0 || curwidth > winInfo.rcWindow.Width) curwidth = winInfo.rcWindow.Width; if (curheight == 0 || curwidth == 0) return null; Graphics frmGraphics = Graphics.FromHwnd(hWnd); IntPtr hDC = GetWindowDC(hWnd); //gets the entire window //IntPtr hDC = frmGraphics.GetHdc(); -- gets the client area, no menu bars, etc.. System.Drawing.Bitmap tmpBitmap = new System.Drawing.Bitmap(curwidth, curheight, frmGraphics); Graphics bmGraphics = Graphics.FromImage(tmpBitmap); IntPtr bmHdc = bmGraphics.GetHdc(); BitBlt(bmHdc, 0, 0, curwidth, curheight, hDC, X1, Y1, TernaryRasterOperations.SRCCOPY); bmGraphics.ReleaseHdc(bmHdc); ReleaseDC(hWnd, hDC); return tmpBitmap; } On Development environment everything is excellent, but on windows server 2008 I have following issues: 1) When there is other window in front my - it is getting captured as well 2) When there is no user connected to RDC - image is black On other hand, I am able to render webpage images using IE. How I can change behaviour of windows rendering process to get proper results?

    Read the article

  • Mac vs. Windows Browser Font Height Rendering Issue

    - by cdmckay
    I'm using a custom font and the @font-face tag. In Windows, everything looks great, regardless of whether it's Firefox, Chrome, or IE. On Mac, it's a different story. For some reason, the Mac font renderer thinks the font is a lot shorter than it is. For example, consider this test code (live example here): <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html> <head> <meta http-equiv="Content-Type" content="text/html; charset=UTF-8" /> <title>Webble</title> <style type="text/css"> @font-face { font-family: "Bubbleboy 2"; src: url("bubbleboy-2.ttf") format('truetype'); } body { font-family: "Bubbleboy 2"; font-size: 30px; } div { background-color: maroon; color: yellow; height: 100px; line-height: 100px; } </style> </head> <body> <div>The quick brown fox jumped over the lazy dog.</div> </body> </html> Open it on Windows Firefox and on Mac Firefox. Use your mouse to select it. On Windows, you'll notice it fully selects the font. On Mac, it only selects about half the font. If you look at what it is selecting, you'll see that that part has been centered, instead of the full height of the font. Is there anyway to fix this rather large discrepancy?

    Read the article

  • Windows 7 dsound.dll load from dll crash

    - by Jonas Byström
    I'm getting a crash when loading dsound.dll from another DLL in Windows 7. The following code crashes: #include <Windows.h> #include <mmreg.h> #include <dsound.h> #include <assert.h> HRESULT (WINAPI *pDirectSoundEnumerateA)(LPDSENUMCALLBACKA pDSEnumCallback, LPVOID pContext); HMODULE hDsound; BOOL CALLBACK DSEnum(LPGUID a, LPCSTR b, LPCSTR c, LPVOID d) { return TRUE; } void CrashTest() { HRESULT hr; hDsound = LoadLibraryA("dsound.dll"); assert(hDsound); *(void**)&pDirectSoundEnumerateA = (void*)GetProcAddress(hDsound, "DirectSoundEnumerateA"); assert(pDirectSoundEnumerateA); hr = pDirectSoundEnumerateA(DSEnum, NULL); assert(!FAILED(hr)); } BOOL APIENTRY DllMain(HANDLE hModule,DWORD ul_reason_for_call,LPVOID lpReserved) { if (ul_reason_for_call == DLL_PROCESS_ATTACH) { DisableThreadLibraryCalls(hModule); CrashTest(); } } with this error code: Unhandled exception at ... in ...: 0xC0000005: Access violation reading location 0x00000044. (it's always 0x44 for some reason). It works on Windows XP or when loading directly from the .exe (not from a separate DLL). Help!?! :)

    Read the article

  • Making pygtksourceview work in windows

    - by Dani
    So, I'm trying to get gtksourceview python bindings work under windows (I'm developing a cross platform gtk application that shows code, so gtksourceview seemed like a natural choice). I have pygtk installed and working (I followed the instructions in http://www.pygtk.org/downloads.html) I tried the instructions in http://projects.gnome.org/gtksourceview/ for gtksourceview. Here is what I did: Downloaded and extracted the latest gtksourceview window binaries from: http://ftp.gnome.org/pub/gnome/binaries/win32/gtksourceview/2.10/gtksourceview-2.10.0.zip The website said gtksourceview needs libxml, so I downloaded and extracted the latest libxml window binaries from: http://xmlsoft.org/sources/win32/libxml2-2.7.6.win32.zip Added the folders containing dll files to the PATH (in my computer they were c:\opt\gtksourceview\bin; C:\opt\libxml2-2.7.6.win32\bin) Installed pygtksourceview with the windows installer: http://ftp.gnome.org/pub/gnome/binaries/win32/pygtksourceview/2.10/pygtksourceview-2.10.0.win32-py2.6.exe Renamed the file libxml2.dll to libxml2-2.dll (after running depends on the gtksourceview dll) Now, the gtksouceview widget seems to work, until I'm trying to set the code's language. When I do that python crashes. Here is how I crash it in the console (the simplest way i could come up with): >>>import gtksourceview2 >>>lang = gtksourceview2.language_manager_get_default().get_language('cpp') >>>lang.get_style_ids() I'm hoping I'm not the first person to use gtksourceview in python on windows. Any ideas what I should try?

    Read the article

  • Shutting down a windows service that has threads

    - by Dave
    I have a windows service written in .NET 3.5 (c#) with a System.Threading.Timer that spawns several Threads in each callback. These are just normal threads (no Thread Pool) and I've set the IsBackground = true on each thread since I'm only going to be running managed code. When a user stops the service, what happens to all the threads? Do they die gracefully? I don't have any code that manages the threads via calling join or abort. Is it correct to assume the IsBackground = true is enough to assume the threads will be disposed and stopped when a user stops the service? What exactly happens when someone stops a windows service via the Service Manager GUI? Does it kill the process after it fires the OnStop event? This would actually be acceptable for me because I've built a separate mechanism that allows a user know for sure there are no threads before they stop the service. This is done via 2 WCF methods exposed from a ServiceHost that runs inside the Windows Service. There's one method to stop spawning new threads and another method to query how many running threads there are left. I'm just curious what happens if they skip those steps and just stop the service... It seems the IsBackground helps achieve this:

    Read the article

  • "NT AUTHORITY\ANONYMOUS LOGON" error in Windows 7 (ASP.NET & Web Service)

    - by Tony_Henrich
    I have an asp.net web app which works fine in Windows XP machine in a domain. I am porting it to a Windows 7 stand alone machine. The app uses a web service which makes a call to sql server. The web server (IIS 7.5) and SQL Server are on the same stand alone machine. I enabled Windows authentication for the website and web service. The web service uses a trusted connection connection string. The web service credentials uses System.Net.CredentialCache.DefaultCredentials. I noticed username, password and domainname are blank after the call! The webservice and web site use an application pool with identity "Network Service". I am getting an exception "NT AUTHORITY\ANONYMOUS LOGON" in the database call in the web service. I am assuming it's related to the blank credentials. I am expecting ASPNET user to be the security token to the database. Why is this not happening? (Usually this happens when sql server and web server are on two different machines in a domain, delegation & double hopping, but in my case everything is on a dev box)

    Read the article

  • Mixing c++ standard strings and windows API

    - by JB
    Many windows APIs take a pointer to a buffer and a size element but the result needs to go into a c++ string. (I'm using windows unicode here so they are wstrings) Here is an example :- #include <iostream> #include <string> #include <vector> #include <windows.h> using namespace std; // This is the method I'm interested in improving ... wstring getComputerName() { vector<wchar_t> buffer; buffer.resize(MAX_COMPUTERNAME_LENGTH+1); DWORD size = MAX_COMPUTERNAME_LENGTH; GetComputerNameW(&buffer[0], &size); return wstring(&buffer[0], size); } int main() { wcout << getComputerName() << "\n"; } My question really is, is this the best way to write the getComputerName function so that it fits into C++ better, or is there a better way? I don't see any way to use a string directly without going via a vector unless I missed something? It works fine, but somehow seems a little ugly. The question isn't about that particular API, it's just a convenient example.

    Read the article

  • Windows cmd encoding change causes Python crash.

    - by Alex
    First I chage Windows CMD encoding to utf-8 and run Python interpreter: chcp 65001 python Then I try to print a unicode sting inside it and when i do this Python crashes in a peculiar way (I just get a cmd prompt in the same window). >>> import sys >>> print u'ëèæîð'.encode(sys.stdin.encoding) Any ideas why it happens and how to make it work? UPD: sys.stdin.encoding returns 'cp65001' UPD2: It just came to me that the issue might be connected with the fact that utf-8 uses multi-byte character set (kcwu made a good point on that). I tried running the whole example with 'windows-1250' and got 'ëeaî?'. Windows-1250 uses single-character set so it worked for those characters it understands. However I still have no idea how to make 'utf-8' work here. UPD3: Oh, I found out it is a known Python bug. I guess what happens is that Python copies the cmd encoding as 'cp65001 to sys.stdin.encoding and tries to apply it to all the input. Since it fails to understand 'cp65001' it crushes on any input that contains non-ascii characters.

    Read the article

  • Hiding/blocking tabs using windows forms in c#

    - by Audel
    The thing is that i have a 'log in window' and a 'mainwindow' that is called after pressing the log in button or the "VISITANT" button If pressing the log in button, the whole system will come out, and if i press the VISITANT button, one tab should disappear or be blocked or something. private void visitant(object sender, EventArgs e) { mainwindow menu = new mainwindow(); menu.Show(); //mainwindow.tabPage1.Enabled = false; //attempt1 //mainwindow.tabPage1.Visible = false; //attempt1 //System.Windows.Forms.tabPage1.Enabled = false;//attempt2 //System.Windows.Forms.tabPage1.Visible = false;//attempt2 this.Hide(); } the errors i get for using the attempt1 are Error 1 'System.mainwindow.tabPage1' is inaccessible due to its protection level' Error 2 An object reference is required for the non-static field, method, or property 'System.mainwindow.tabPage1' and the one i get for using the attempt2 is Error 1 The type or namespace name 'tabPage1' does not exist in the namespace 'System.Windows.Forms' (are you missing an assembly reference?) as you probably have guessed "tabPage1" is the tab i need to hide when pressing the visitant button. I can't think of any more details, I will be around to provide any extra information Thanks in advance.

    Read the article

  • multi-core processing in R on windows XP - via doMC and foreach

    - by Jan
    Hi guys, I'm posting this question to ask for advice on how to optimize the use of multiple processors from R on a Windows XP machine. At the moment I'm creating 4 scripts (each script with e.g. for (i in 1:100) and (i in 101:200), etc) which I run in 4 different R sessions at the same time. This seems to use all the available cpu. I however would like to do this a bit more efficient. One solution could be to use the "doMC" and the "foreach" package but this is not possible in R on a Windows machine. e.g. library("foreach") library("strucchange") library("doMC") # would this be possible on a windows machine? registerDoMC(2) # for a computer with two cores (processors) ## Nile data with one breakpoint: the annual flows drop in 1898 ## because the first Ashwan dam was built data("Nile") plot(Nile) ## F statistics indicate one breakpoint fs.nile <- Fstats(Nile ~ 1) plot(fs.nile) breakpoints(fs.nile) # , hpc = "foreach" --> It would be great to test this. lines(breakpoints(fs.nile)) Any solutions or advice? Thanks, Jan

    Read the article