Search Results

Search found 37415 results on 1497 pages for 'attribute id'.

Page 6/1497 | < Previous Page | 2 3 4 5 6 7 8 9 10 11 12 13  | Next Page >

  • Problem on getting the vendor id and product id of a usb device

    - by new
    Hi... my application comes and prints this "\?\usb#vid_04f2&pid_0111#5&1ba5a77f&0&2#{a5dcbf1 0-6530-11d2-901f-00c04fb951ed}" again it goes to while loop .... here it gets breaked in the else statement... Qt Code: if (GetLastError() == ERROR_INSUFFICIENT_BUFFER) { // Change the buffer size. if (buffer) LocalFree(buffer); buffer = (LPTSTR)LocalAlloc(LPTR,buffersize); } else { qDebug ()<<"Here it quits the application"; // Insert error handling here. break; } Any ideas in this.... full source code comes here static GUID GUID_DEVINTERFACE_USB_DEVICE = { 0xA5DCBF10L, 0x6530, 0x11D2, { 0x90, 0x1F, 0x00, 0xC0, 0x4F, 0xB9, 0x51, 0xED } }; HANDLE hInfo = SetupDiGetClassDevs(&GUID_DEVINTERFACE_USB_DEVICE,NULL,NULL, DIGCF_PRESENT | DIGCF_INTERFACEDEVICE); if ( hInfo == INVALID_HANDLE_VALUE ) { qDebug ()<<"invalid"; } else { qDebug ()<<"valid handle"; SP_DEVINFO_DATA DeviceInfoData; DeviceInfoData.cbSize = sizeof(SP_DEVINFO_DATA); SP_INTERFACE_DEVICE_DATA Interface_Info; Interface_Info.cbSize = sizeof(Interface_Info); BYTE Buf[1024]; DWORD i; DWORD InterfaceNumber= 0; PSP_DEVICE_INTERFACE_DETAIL_DATA pspdidd = (PSP_DEVICE_INTERFACE_DETAIL_DATA) Buf; for (i=0;SetupDiEnumDeviceInfo(hInfo,i,&DeviceInfoData);i++) { DWORD DataT; LPTSTR buffer = NULL; DWORD buffersize = 0; while (!SetupDiGetDeviceRegistryProperty( hInfo, &DeviceInfoData,SPDRP_DEVICEDESC, &DataT,(PBYTE)buffer,buffersize, &buffersize)) { if (GetLastError() == ERROR_INSUFFICIENT_BUFFER) { // Change the buffer size. if (buffer) LocalFree(buffer); buffer = (LPTSTR)LocalAlloc(LPTR,buffersize); } else { // Insert error handling here. break; } qDebug ()<<(TEXT("Device Number %i is: %s\n"),i, buffer); if (buffer) LocalFree(buffer); if ( GetLastError() != NO_ERROR && GetLastError() != ERROR_NO_MORE_ITEMS ) { // Insert error handling here. qDebug ()<<"return false"; } InterfaceNumber = 0; // this just returns the first one, you can iterate on this if (SetupDiEnumDeviceInterfaces(hInfo, NULL, &GUID_DEVINTERFACE_USB_DEVICE, InterfaceNumber, &Interface_Info)) { printf("Got interface"); DWORD needed; pspdidd->cbSize = sizeof(*pspdidd); SP_DEVICE_INTERFACE_DETAIL_DATA *pDetData = NULL; DWORD dwDetDataSize = sizeof (SP_DEVICE_INTERFACE_DETAIL_DATA) + 256; pDetData = (SP_DEVICE_INTERFACE_DETAIL_DATA*) malloc (dwDetDataSize); pDetData->cbSize = sizeof (SP_DEVICE_INTERFACE_DETAIL_DATA); SetupDiGetDeviceInterfaceDetail(hInfo,&Interface_Info, pDetData,dwDetDataSize, NULL,&DeviceInfoData); qDebug ()<<pDetData->DevicePath; qDebug ()<<QString::fromWCharArray(pDetData->DevicePath); free(pDetData); } else { printf("\nNo interface"); //ErrorExit((LPTSTR) "SetupDiEnumDeviceInterfaces"); if ( GetLastError() == ERROR_NO_MORE_ITEMS) printf(", since there are no more items found."); else printf(", unknown reason."); } // Cleanup SetupDiDestroyDeviceInfoList(hInfo); } } }

    Read the article

  • Attribute Address getting displayed instead of Attribute Value

    - by Manish
    I am try to create the following. I want to have one drop down menu. Depending on the option selected in the first drop down menu, options in second drop down menu will be displayed. The options in 2nd drop down menu is supposed by dynamic, i.e., options change with the change of values in first menu. Here, instead of getting the drop down menus, I am getting the following Choose your Option1: Choose your Option2: Note: I strictly don't want to use javascript. home_form.py class HomeForm(forms.Form): def __init__(self, *args, **kwargs): var_filter_con = kwargs.pop('filter_con', None) super(HomeForm, self).__init__(*args, **kwargs) if var_filter_con == '***': var_empty_label = None else: var_empty_label = ' ' self.option2 = forms.ModelChoiceField(queryset = db_option2.objects.filter(option1_id = var_filter_con).order_by("name"), empty_label = var_empty_label, widget = forms.Select(attrs={"onChange":'this.form.submit();'}) ) self.option1 = forms.ModelChoiceField(queryset = db_option1.objects.all().order_by("name"), empty_label=None, widget=forms.Select(attrs={"onChange":'this.form.submit();'}) ) view.py def option_view(request): if request.method == 'POST': form = HomeForm(request.POST) if form.is_valid(): cd = form.cleaned_data if cd.has_key('option1'): f = HomeForm(filter_con = cd.get('option1')) return render_to_response('homepage.html', {'home_form':f,}, context_instance=RequestContext(request)) return render_to_response('invalid_data.html', {'form':form,}, context_instance=RequestContext(request)) else: f = HomeForm(filter_con = '***') return render_to_response('homepage.html', {'home_form':f,}, context_instance=RequestContext(request)) homepage.html <!DOCTYPE HTML> <head> <title>Nivaaran</title> </head> <body> <form method="post" name = 'choose_opt' action=""> {% csrf_token %} Choose your Option1: {{ home_form.option1 }} <br/> Choose your Option2: {{ home_form.option2 }} </form> </body>

    Read the article

  • SELECT set of most recent id, amount FROM table, where id occurs many times

    - by Jon Cram
    I have a table recording the amount of data transferred by a given service on a given date. One record is entered daily for a given service. I'd like to be able to retrieve the most recent amount for a set of services. Example data set: serviceId | amount | date ------------------------------- 1 | 8 | 2010-04-12 2 | 11 | 2010-04-12 2 | 14 | 2010-04-11 3 | 9 | 2010-04-11 1 | 6 | 2010-04-10 2 | 5 | 2010-04-10 3 | 22 | 2010-04-10 4 | 17 | 2010-04-19 Desired response (service ids 1,2,3): serviceId | amount | date ------------------------------- 1 | 8 | 2010-04-12 2 | 11 | 2010-04-12 3 | 9 | 2010-04-11 Desired response (service ids 2, 4): serviceId | amount | date ------------------------------- 2 | 11 | 2010-04-12 4 | 17 | 2010-04-19 This retrieves the equivalent as running the following once per serviceId: SELECT serviceId, amount, date FROM table WHERE serviceId = <given serviceId> ORDER BY date DESC LIMIT 0,1 I understand how I can retrieve the data I want in X queries. I'm interested to see how I can retrieve the same data using either a single query or at the very least less than X queries. I'm very interested to see what might be the most efficient approach. The table currently contains 28809 records. I appreciate that there are other questions that cover selecting the most recent set of records. I have examined three such questions but have been unable to apply the solutions to my problem.

    Read the article

  • Magento- custom attribute causes blank order number.

    - by frank
    Hi- I created a simple custom attribute on the sales/order entity. Now, for new orders, order number is null. I looked at the sales_order table, and sure enough, increment_id is null... can anyone help me out, I am stumped? This is my setup.php: `public function getDefaultEntities() { return array( 'order' => array( 'entity_model' => 'sales/order', //'attribute_model' => 'catalog/resource_eav_attribute', 'table' => 'sales/order', 'attributes' => array( 'pr_email_sent' => array( 'label' => 'prEmailSent', 'type' => 'varchar', 'default' => 'false' ), ) ) ); }` This is my config.xml <fieldsets> <sales_order> <pr_email_sent><create>1</create><update>1</update></pr_email_sent> </sales_order> </fieldsets> Thanks.

    Read the article

  • JSF2: Re-render all components on page that have a given ID, without absolute paths

    - by tlind
    Is there any way in JSF 2.0/PrimeFaces of re-rendering all components (using the PrimeFaces update="id1 id2..." attribute or the <f:ajax render="..."/> tag) that have got a given ID, regardless of whether they are in the same form that contains the button triggering the AJAX re-render or not? For example, I want my button to re-render all sections on a page that visualize the user's current shopping basket. Right now, I always have to specify the absolute path to the components that I want to get updated, e.g. update=":header:basket :left-sidebar:menu:basket" which is rather impractical if the structure of the page changes (besides, I have not been able to figure out the correct path for one of these components). I already tried to implement a custom EL function like this, which traverses the component tree: update="{utilBean.findAllComponentsMatchingId('basket')}" but at the time that function is evaluated, apparently not the entire component tree has been set up as it doesn't contain the components I am looking for. How can I deal with this? There certainly must be an easy way of doing AJAX-based updates of sections of the page that are not part of the current <h:form>? Thanks!

    Read the article

  • Are GUIDs the ultimate ID?

    - by mafutrct
    I noticed some people don't bother having the usual incremented number as ID but instead simply generate a GUID. The advantages include: Quick and easy No need to keep track of previous IDs Guaranteed to be unique even across machines without knowledge of each other Some disadvantages are: Possibly performance bottleneck Uses a large number of bytes My understanding is that using a GUID is beneficial in most cases, except if optimization for time or space is an issue. Did I miss something? Or do you agree with this idea?

    Read the article

  • Creating a MySQL view with an auto-incrementing id column

    - by hmemcpy
    I have a MySQL database from which a view is created. Is is possible to add an auto-incrementing id for each row in the view? I tried CREATE ALGORITHM=UNDEFINED DEFINER=`database_name`@`%` SQL SECURITY DEFINER VIEW `MyView` AS set @i = 0; select @i:=@i+1 as `id` ... but that doesn't work in a View. Sorry, my SQL is weak, any help is appreciated.

    Read the article

  • SQL MDS - Updating the Name attribute of member using Staging Table

    - by Randy Aldrich Paulo
    Creating member is usually done by populating the Member Staging Table (tblStgMember), during this process you assign a value for member code and member name. Now if you want to update the member name attribute you can do this by adding record in Attribute staging table (tblStgMemberAttribute) with Attribute Name = "Name". If you try populating the tblStgMember table it will say that the member code already exists.   INSERT INTO mdm.tblStgMemberAttribute (ModelName, EntityName, MemberType_ID, MemberCode, AttributeName, AttributeValue) VALUES (N'Product', N'Product', 1, N'BK-M101', N'Name',N'Updated Member Name Description')

    Read the article

  • NHibernate Pitfalls: Private Setter on Id Property

    - by Ricardo Peres
    Having a private setter on an entity’s id property may seem tempting: in most cases, unless you are using id generators assigned or foreign, you never have to set its value directly. However, keep this in mind: If your entity is lazy and you want to prevent people from setting its value, make the setter protected instead of private, because it will need to be accessed from subclasses of your entity (generated by NHibernate); If you use stateless sessions, you can perform some operations which, on regular sessions, require you to load an entity, without doing so, for example: 1: using (IStatelessSession session = factory.OpenStatelessSession()) 2: { 3: //delete without first loading 4: session.Delete(new Customer { Id = 1 }); 5:  6: //insert without first loading 7: session.Insert(new Order { Customer = new Customer { Id = 1 }, Product = new Product { Id = 1 } }); 8:  9: //update without first loading 10: session.Update(new Order{ Id = 1, Product = new Product{ Id = 2 }}) 11: }

    Read the article

  • Retrieve .Net Control ID in Javascript

    - by Vipin
    Originally posted on: http://geekswithblogs.net/Vipin/archive/2013/07/24/retrieve-.net-control-id-in-javascript.aspxIf you need to retrieve a client ID of an asp:net control in a javascript function, then you can use the below function - function $$(id, context) { var el = $("#" + id, context); if (el.length < 1) el = $("[id$=_" + id + "]", context); return el; }   var tempDotNetControl = 'aspTextTemporary';   var ClientSideID = $$(aspTextTemporary); Please bear in mind, this function is useful if you want to retrieve client ID of a different DotNet control based on some condition, otherwise if it’s always static then you can just use <%= aspTextTemporary.ClientID %>"

    Read the article

  • h1 title attribute [closed]

    - by codemonkey
    Possible Duplicate: Why don't TITLE tags get indexed in google? Hello there, I have a h1 element on my page which is working great. I have also been using the title attribute on this element which I don't think has been causing much harm at all. My h1 title is "The Great Ocean Road" and the title attribute on that is "Great Ocean Road" - so it's a variation of the h1 text. These are both keywords for the site so i'm hoping it's a good thing for seo. Is that a bad idea do you think? I'm not sure what Search Engines think about using a title attribute or even if they would 'mark me down' for doing it in such a way. Do you think if the h1 text is "The Great Ocean Road", the title attribute should be "The Great Ocean Road" aswell? Thank you in advance

    Read the article

  • Identifying methods with a specified Id in D [migrated]

    - by Ekyo777
    I want to have specific methods with a specific pattern recognized at compile time and registered along with a specified id trough mixins in a parent class. ex.: take a method 'X' from a class with a predetermined id:5, what I want is that, in a mixin in a parent class, method X will be registered as a delegate with its id to be called later on by its id. What would be the best way to specify the Id considering I want the id to be of type int and only the specified methods to be registered? should I (if it is even possible) do it with a custom annotation pretty much like the @property but with an argument, like: @autoregister(id) void method(...) if it is possible to do it this way, an example or a link to the documentation on how to do it would be nice since I didn't find it in the documentation.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Hashes vs Numeric id's

    - by Karan Bhangui
    When creating a web application that some how displays the display of a unique identifier for a recurring entity (videos on YouTube, or book section on a site like mine), would it be better to use a uniform length identifier like a hash or the unique key of the item in the database (1, 2, 3, etc). Besides revealing a little, what I think is immaterial, information about the internals of your app, why would using a hash be better than just using the unique id? In short: Which is better to use as a publicly displayed unique identifier - a hash value, or a unique key from the database? Edit: I'm opening up this question again because Dmitriy brought up the good point of not tying down the naming to db specific property. Will this sort of tie down prevent me from optimizing/normalizing the database in the future? The platform uses php/python with ISAM /w MySQL.

    Read the article

  • django getting current user id

    - by dana
    hello, i have a mini app where users can login, view their profile, and follow each other. 'Follow' is a relation like a regular 'friend' relationship in virtual communities, but it is not necessarily reciprocal, meaning that one can follow a user, without the need that the user to be following back that person who follows him. my problem is: if i am a logged in user, and i navigate to a profile X, and push the button follow, how can i take the current profile id ?(current profile meaning the profile that I, the logged in user, am viewing right now.) the view: def follow(request): if request.method == 'POST': form = FollowForm(request.POST) if form.is_valid(): new_obj = form.save(commit=False) new_obj.initiated_by = request.user u = User.objects. what here? new_obj.follow = u new_obj.save() return HttpResponseRedirect('.') else: form = FollowForm() return render_to_response('followme/follow.html', { 'form': form, }, context_instance=RequestContext(request)) thanks in advance!

    Read the article

  • CryptGenRandom to generate asp.net session id

    - by DoDo
    Hi! does anyone have working example of CryptGenrRandom class to generate session id (need to use in my iis module). HCRYPTPROV hCryptProv; BYTE pbData[16]; if(CryptAcquireContext( &hCryptProv, NULL, NULL, PROV_RSA_FULL, CRYPT_VERIFYCONTEXT)) { if(CryptGenRandom(hCryptProv, 8, pbData)) { std::string s(( const char *) pbData); printf(s.c_str()); } else { MyHandleError("Error during CryptGenRandom."); } } else { MyHandleError("Error during CryptAcquireContext!\n"); } i tried this code but, its not working quite well (i get it from msdn) and this example don't work for me ( http://www.codeproject.com/KB/security/plaintextsessionkey.aspx ) so if anyone know how to generate sessionid using this class plz let me know tnx anyway!

    Read the article

  • jQuery create new div with ID?

    - by John
    Hello, I have form in my ASP.NET masterPage.master and if i click on submit it call some method from masterPage.master.cs file by ajax (i have it in update panel). But i want improve it with jQuery. So i have this: $('#submit').click(function () { $.ajax({ type: "POST", url: '<% Response.Write("~"+Request.Path); %>', beforeSend: function () { $(document.createElement('div')).width($('#formBox').width()) .height($('#formBox').height()) .css({ backgroundImage: 'url(/Static/Img/bc_overlay.png)', position: 'absolute', left: 0, top: 0, margin: "5px", textAlign: "center", color: "#000", display: "none" }) .append("<strong>Nacítám</strong><br /><img src='Static/Img/ajax-loader.gif' width='33px' height='33px' alt='loading' />") .fadeIn("slow") .prependTo($('#formBox')); $('#formBox').css('position', 'relative'); }, success: function () { } }); }); So if i click on submit, new div is creating (there is loading text and image, and cool opacity overlay), but how i give to this div some ID? Because i need use it in success: function () { } i need clear this box and write here some text (error or success).

    Read the article

  • C++ boost thread id and Singleton

    - by aaa
    hi. Sorry to flood so many questions this week. I assume thread index returned by thread.get_id is implementation specific. In case of the pthreads, is index reused? IE, if thread 0 runs and joins, is thread launched afterwords going to have a different ID? the reason I ask this is a need to implement Singleton pattern with a twist: each thread gets its own instance. I know it sounds very crazy, but threads control hardware (cuda) which does not permit device memory sharing. What is a good way to implement such pattern?

    Read the article

  • Need to find number of new unique ID numbers in a MySQL table

    - by Nicholas
    I have an iPhone app out there that "calls home" to my server every time a user uses it. On my server, I create a row in a MySQL table each time with the unique ID (similar to a serial number) aka UDID for the device, IP address, and other data. Table ClientLog columns: Time, UDID, etc, etc. What I'd like to know is the number of new devices (new unique UDIDs) on a given date. I.e. how many UDIDs were added to the table on a given date that don't appear before that date? Put plainly, this is the number of new users I gained that day. This is close, I think, but I'm not 100% there and not sure it's what I want... SELECT distinct UDID FROM ClientLog a WHERE NOT EXISTS ( SELECT * FROM ClientLog b WHERE a.UDID = b.UDID AND b.Time <= '2010-04-05 00:00:00' ) I think the number of rows returned is the new unique users after the given date, but I'm not sure. And I want to add to the statement to limit it to a date range (specify an upper bound as well).

    Read the article

  • In ADUC MMC, Advanced View, how to get Attribute Editor tab on the result of a Find?

    - by geoffc
    In Win2008 MS added a new Tab on objects in ADUC. Called Attribute Editor it is like Novell Console One's Other tab, or an arbitrary LDAP editor view, or an ADSI Edit style view. Basically it shows all allowed attributes for the object class, and allows you to edit according to your permissions. You need to enable Advanced Options in the View menu before it shows up. This is great, however it only shows up when you browse the directory tree and select an object. If you use the Find tool and open an object Attribute Editor is not shown. How annoying! Especially if your domain has more than 2000 users in a single container, then you almost must use Find to get to an object. Is there any way to make the Attribute Editor tab show up after using Find to open an object?

    Read the article

  • returning correct multiTouch id

    - by Max
    I've spent countless hours on reading tutorials and looking at every question related to multiTouch from here and Stackoverflow. But I just cannot figure out how to do this correctly. I use a loop to get my pointerId, I dont see alot of people doing this but its the only way I've managed to get it somewhat working. I have two joysticks on my screen, one for moving and one for controlling my sprites rotation and the angle he shoots, like in Monster Shooter. Both these work fine. My problem is that when I Move my sprite at the same time as Im shooting, my touchingPoint for my movement is set to the touchingPoint of my shooting, since the x and y is higher on the touchingPoint of my shooting (moving-stick on left side of screen, shooting-stick on right side), my sprite speeds up, this creates an unwanted change in speed for my sprite. I will post my entire onTouch method here with some variable-changes to make it more understandable. Since I do not know where Im going wrong. public void update(MotionEvent event) { if (event == null && lastEvent == null) { return; } else if (event == null && lastEvent != null) { event = lastEvent; } else { lastEvent = event; } int pointerCount = event.getPointerCount(); for (int i = 0; i < pointerCount; i++) { int x = (int) event.getX(i); int y = (int) event.getY(i); int id = event.getPointerId(i); int action = event.getActionMasked(); int actionIndex = event.getActionIndex(); String actionString; switch (action) { case MotionEvent.ACTION_DOWN: actionString = "DOWN"; break; case MotionEvent.ACTION_UP: shooting=false; // when shooting is true, it shoots dragging=false; // when dragging is true, it moves actionString = "UP"; break; case MotionEvent.ACTION_POINTER_DOWN: actionString = "PNTR DOWN"; break; case MotionEvent.ACTION_POINTER_UP: shooting=false; dragging=false; actionString = "PNTR UP"; break; case MotionEvent.ACTION_CANCEL: shooting=false; dragging=false; actionString = "CANCEL"; break; case MotionEvent.ACTION_MOVE: try{ if((int) event.getX(id) > 0 && (int) event.getX(id) < touchingBox && (int) event.getY(id) > touchingBox && (int) event.getY(id) < view.getHeight()){ movingPoint.x = (int) event.getX(id); movingPoint.y = (int) event.getY(id); dragging = true; } else if((int) event.getX(id) > touchingBox && (int) event.getX(id) < view.getWidth() && (int) event.getY(id) > touchingBox && (int) event.getY(id) < view.getHeight()){ shootingPoint.x = (int) event.getX(id); shootingPoint.y = (int) event.getY(id); shooting=true; }else{ shooting=false; dragging=false; } }catch(Exception e){ } actionString = "MOVE"; break; default: actionString = ""; } Wouldnt post this much code if I wasnt at an absolute loss of what I'm doing wrong. I simply can not get a good understanding of how multiTouching works. basicly movingPoint changes for both my first and second finger. I bind it to a box, but aslong as I hold one finger within this box, it changes its value based on where my second finger touches. It moves in the right direction and nothing gives an error, the problem is the speed-change, its almost like it adds up the two touchingPoints.

    Read the article

  • AD Custom Attribute with unique value

    - by Zilog
    I have custom AD attribute added to my AD schema. Attribute's syntax is Unicode String. It is added to user class and the purpose of it is to store user ID of corporate ERP system. Problem is, that I can have two or more user objects with the same value stored in that attribute, which is something that I would like to avoid. Is there a way to configure AD attribute so it is unique within the domain boundary? (The same behavior as SAMAccountName attribute.) i.e : If there already exists user object in AD with this attribute set to "JSmith" and I try to set that attribute with the same value for another user, Direcory Services will refuse to update that object and give me "already exists" error. Domain functional level is windows 2003.

    Read the article

< Previous Page | 2 3 4 5 6 7 8 9 10 11 12 13  | Next Page >