Search Results

Search found 10859 results on 435 pages for 'raid controller'.

Page 64/435 | < Previous Page | 60 61 62 63 64 65 66 67 68 69 70 71  | Next Page >

  • session variable not available in global before(:each, :type => :controller)

    - by Rob
    Hi, I'm refactoring some specs, in controller specs I have a before(:each) which sets up things required in the session my before filter is... config.before(:each, :type => :controller) do ... session[:current_user] = @user session[:instance] = @instance ... end @user and @instance are also set in the before(:each) i've just hidden them for readability here I get the following error when running the controller tests undefined method `session' for nil:NilClass I would expect the global before callbacks to have the same things as the ones in the individual tests but I guess maybe they are loaded before the rails environment has been initialised? Thanks

    Read the article

  • Route Values for Area (MVC3)

    - by Jim
    Hi, I am using areas in MVC version 3. My logoff and logon action methods are routing to the area, and I need them to route to the normal controller that is not in an area. I have tried the following host://AREA/CONTROLLER/METHOD instead of host://CONTROLLER/METHOD. @if(Request.IsAuthenticated) { <text>Welcome <b>@Context.User.Identity.Name</b> [ @Html.ActionLink("Log Off", "LogOff", "Account", new { area = "" }) ]</text> } else { @:[ @Html.ActionLink("Log On", "LogOn", "Account", new { area = "" }) ] }

    Read the article

  • CI controller function is ignored

    - by den-javamaniac
    Hi. I'm trying to pass through a CI tutorial (writing a simple forum) and I can't make a controller function called. To be more specific I have this in a controller: function __construct() { parent::Controller(); $this->load->helper('url'); } function index() { $data['title'] = "Wlcome to Gossip"; $data['heading'] = "Welcome to Gossip"; $data['query'] = $this->db->get('topic')->result(); $this->load->view('welcome', $data); } function topic() { echo 'testing...'; } and when I'm trying to access the /index.php/forum/topic/ uri it just prints out my index() function. Can any one point out what may cause the problem?

    Read the article

  • render json data returned from mvc controller

    - by user1765862
    I'm having js function which calls mvc controller action method which return list of data as json. function FillCountryCities(countryId) { $.ajax({ type: 'GET', url: '/User/FillCityCombo', data: { countryId: countryId }, contentType: 'application/json', success: function (data) { alert(data[0].Name); } error: function () { alert('something bad happened'); } .... format of data which sent back from controller is Name (string) and Id (Guid) Now I just want to alert Name on success first item from collection. Double checked controller sends 20 records, so it should alert first from collection but I'm getting error something bad happened update: public JsonResult FillCityCombo(Guid countryId) { var cities = repository.GetData() .Where(x = x.Country.Id == countryId).ToList(); if (Request.IsAjaxRequest()) { return new JsonResult { Data = cities, JsonRequestBehavior = JsonRequestBehavior.AllowGet }; } else { return new JsonResult { Data = "Not Valid Request", JsonRequestBehavior = JsonRequestBehavior.AllowGet }; } }

    Read the article

  • new controller in oo php

    - by pradeep
    Hi , I have a practical doubt , I am using OO php , and i am new to it. I am using zend framework to be clear. I am writing controllers(class) and actions(methods) with in it say PatientMapper.php which has all single mysql table related actions and Patient.php which has all setter and getter functions. I get a doubt that when should i write a new controller. Should i write a controller for all the actions on a single mysql table . or a single controller for all actions related to a module.

    Read the article

  • HP P212 hangs on Initializing

    - by user927586
    I'm in trouble... Server: HP Microserver N36L Storage: HP P212/256 with BBWC Drives: 4 WD 2 Tb While expanding the RAID 5 array from 3 to 4 drives, the server rebooted itself. Expansion was at 76%. Now at boot the P212 seems to hang on initializing. After some time screen resets and the server boots, but in the os (Windows Server 2008R2) the P212 has errors (error code 10) and it's not seen by the HP ACU. Whats' going on? It's trying to complete the expansion? It's trying to make all over the expansion? It's simply stuck? What should I do? I NEED the data on the array! PS In the server BIOS, on the hd boot priority, the server still reports the array logical drive... maybe it's a good sign... PPS I'm not at the server physical location, so I cannot tell if the drives in the array are being accessed (that would be the case if the controller it's redoing/completing the expansion process) or not right now. Bye Dario

    Read the article

  • Megacli is killing me, any help appreciated

    - by Stefan
    I run a server with 2 drives in raid0 configured through BIOS. I just added 2 more drives using hotplug (the server is dell r610 with RHEL 5.4 64bit) and I would like to configure a separate raid0 partition on these drives. I am getting the following error: /opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd r0[32:2, 32:3] -a0 The specified physical disk does not have the appropriate attributes to complete the requested command. Exit Code: 0x26 All the parameters are correct and there is just no reason why this command could not work, see this (fujitsu is current raid, seagate is the new one I want to create): /opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL | egrep 'Adapter|Enclosure|Slot|Inquiry' Adapter #0 Enclosure Device ID: 32 Slot Number: 0 Enclosure position: 0 Inquiry Data: FUJITSU MBD2147RC D807D0A4PA101174 Enclosure Device ID: 32 Slot Number: 1 Enclosure position: 0 Inquiry Data: FUJITSU MBD2147RC D807D0A4PA10115T Enclosure Device ID: 32 Slot Number: 2 Enclosure position: 0 Inquiry Data: SEAGATE ST9300603SS FS033SE0TF5K Enclosure Device ID: 32 Slot Number: 3 Enclosure position: 0 Inquiry Data: SEAGATE ST9300603SS FS023SE070FK I also tried to set up the drive as hotspare, also some strange error: /opt/MegaRAID/MegaCli/MegaCli64 -PDHSP -Set -physdrv[32:3] -a0 Adapter: 0: Set Physical Drive at EnclId-32 SlotId-3 as Hot Spare Failed. FW error description: The specified device is in a state that doesn't support the requested command. Exit Code: 0x32 As you can see the disk is in Unconfigured, Good state: Enclosure Device ID: 32 Slot Number: 3 Enclosure position: 0 Device Id: 3 Sequence Number: 1 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.875 GB [0x22dc0000 Sectors] Firmware state: Unconfigured(good), Spun Up SAS Address(0): 0x5000c50005cd20b1 SAS Address(1): 0x0 Connected Port Number: 3(path0) Inquiry Data: SEAGATE ST9300603SS FS023SE070FK FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: Foreign Foreign Secure: Drive is not secured by a foreign lock key Device Speed: Unknown Link Speed: Unknown Media Type: Hard Disk Device Drive Temperature :30C (86.00 F)

    Read the article

  • mdadm+zfs vs mdadm+lvm

    - by Alex
    This may be a naive question since I'm new to this and I cannot find any results about mdadm+zfs, but after some testing it seems it might work: The use case is a server with RAID6 for some data that is backed-up somewhat infrequently. I think I'm well served by any of ZFS or RAID6. Platform is Linux. Performance is secondary. So the two setups I am considering are: A RAID6 array plus regular LVM and ext4 A RAID6 array plus ZFS (without redundancy). Is this second option that I don't see discussed at all. Why ZFS+RAID6? It's mainly because the inability of ZFS to grow a raidz2 with new disks. You can replace disks with larger ones, I know, but not add another disk. You can accomplish 2-disk redundancy and ZFS disk growth using mdadm as the redundancy layer. Besides that main point (otherwise I could go directly to raidz2 without RAID under it), these are the pros-cons that I see for each option: ZFS has snapshots without preallocated space. LVM requires preallocation (might be no longer true). ZFS has checksumming (very interested in this) and compression (nice bonus). LVM has online filesystem growth (ZFS can do it offline with export/mdadm --grow/import). LVM has encryption (ZFS-on-Linux has not). This is the only major con of this combo I see. I guess I could go RAID6+LVM+ZFS... seems too heavy, or not? So, to close with a proper question: 1) Is there anything that inherently discourages or precludes RAID6+ZFS? Anyone has experience with a setup like this? 2) Are there possibilities for checksumming and compression that would make ZFS unnecessary (maintaining the possibility of filesystem growth)? Because the RAID6+LVM combo seems the sanctioned, tested way.

    Read the article

  • Setting up multiple servers for one domain

    - by Joseph Torraca
    So I am starting up a new website and I was wondering how to set up 5 servers to host the site. I have already purchased 5 Apple XServes, one will be used as a test server and the other 4 will be for the live site. So I have read some website on the internet and they all reference using one server and installing software onto it and have that server do the load balancing. I have also read that you could use a hardware, rack-mounted system and plug the servers into that. The load balancer would then distribute the load. So I have a few questions about each: 1) How do you set up the software version and have the other servers as "slaves" and have one "master" to direct traffic? 2) Which of the two options above are more reliable, and better suited for a startup that doesn't have many users per month, yet(hopefully)? 3) Is there a theoretical max limit of servers that can be connected to a software load balancing system? Note: Obviously this will change from software to software, but in terms of the server being able to handle it? 4) In your own opinion, what are you using for your sites? Have you had any problems setting up that system or operating it once its running? Are there any things you would stay away from if you had to start over? 5) I also purchased a Apple RAID system, so if you are familiar with it, is there any way to connect it to multiple Xserves so they all serve the same data? I'm a little confused on this, so thanks for all your help and being patient with me. Note: Take it easy on me, I am learning this as I go along, so I may have used terms incorrectly or explained things that don't really make sense. Sorry. P.S. If you need me to supply the specs on the servers to determine which system makes the most sense, I can post them for you.

    Read the article

  • How do I diagnose a bottleneck in an Intel Atom based Ubuntu server?

    - by Jon Cage
    I have a small media server at home which has software raid and a gigabit link to the rest of my network. For some reason though, I only get ~10MB/s transfers when copying to/from the server. I use software RAID5 (mdadm) over 4 1TB disks. On top of that I then use LVM to give me a huge pool of disk space which is then split up into multiple partitions which can be resized as and when they need it. I'm guessing this it most likely the cause, but I'd like to know for sure where the root cause is. So, how can I benchmark network throughput (Windows 7 desktop <- Ubuntu server) and hard disk performance to try and identify where my bottleneck might be? [Edit] If anyone's interested, the motherboard is an Intel Desktop Board D945GCLF2. So that's a 300 series Atom processor with the Intel® 945GC Express Chipset [Edit2] I feel like such a fool! I just checked my desktop and I had the slower of the two onboard NICs plugged in so the server is probably not at fault here. Transferring a copy of ubuntu off the server I get ~35-40MB/s according to Windows 7. I'll do those HD tests when I get a chance though (just for completeness).

    Read the article

  • Server nearly unusable when doing disk writes

    - by Wikser
    My question closely relates to my last question here on serverfault. I was copying about 5GB from a 10 year old desktop computer to the server. The copy was done in Windows Explorer. In this situation I would assume the server to be bored by the dataflow. But as usual with this server, it really slowed down. At least I could work with the remote session, even there was some serious latency. The copy took its time (20min?). In this time I went to a colleague and he tried to log in in the same server via remote desktop (for some other reason). It took about a minute to get to the login screen, a minute to open the control panel, a minute to open the performance monitor, ... Icons were loading maybe one per second. We saw the following (from memory): CPU: 2% Avg. Queue Length: 50 Pages/sec: 115 (?) There was no other considerable activity on the server. The server seldom serves some ASP.NET pages, which became also very slow in this time. The relevant configuration is as follows: Windows 2003 SEAGATE ST3500631NS (7200 rpm, 500 GB) LSI MegaRAID based RAID 5 4 disks, 1 hot spare Write Through No read-ahead Direct Cache Mode Harddisk-Cache-Mode: off Is this normal behaviour for such a configuration? What measurements could give further clues? Is it reasonable to reduce the priority of such copy I/O and favour other processes like the remote desktop? How would you do that? Many thanks!

    Read the article

  • Create a partition table on a hardware RAID1 drive with [c]fdisk

    - by Lev Levitsky
    My question is, is there a reason for this not to work? Details: I have two 500 Gb drives, and my motherboard RAID support, so I created a RAID1 array and booted from a Linux live medium. I then listed the disks and, apart from the obvious /dev/sda, /dev/sdb, etc. there was /dev/md126 which, I figured, was the mirrored "virtual" drive. Its size was 475 Gb; I had seen that the size of the array would be smaller than 500 Gb when I was creating it, so no surprise there. I did cfdisk /dev/md126, created the necessary partitions and chose write. It's been about half an hour now, I think. It doesn't seem like it's ever going to finish. The only thing about cfdisk in dmesg is that it's "blocked for more than 120 seconds". Doing fdisk -l /dev/md126 in another terminal I see all three partitions I created and a note that "Partition 1 does not start on a physical sector boundary". The table is lost after reboot, though. I tried to partition /dev/sda individually, and it worked, the table was written in about a second. The "not on a physical sector boundary" message is there, too. EDIT: I tried fdisk on /dev/sda, then there were no messages about sector boundaries. After a reboot, I am able to use mkfs on /dev/dm126p1, etc. fdisk shows that /dev/md126 has the same partitions as /dev/sda (but /dev/sdb doesn't have any). But at some point ("writing superblock and filesystem accounting information") mkfs is also blocked. Using it on sda1 results in a "partition is used by the system" error. What can be the problem? EDIT 2: I booted a freshly updated system from a pendrive and was able to create partition table and filesystems on /dev/md126 without any apparent problems. Was it an issue with the support of the hardware? My MB is Asus P9X79.

    Read the article

  • Sparing level on HP EVA 4000

    - by Samuel
    One of the disks of our EVA4000 died today. This diskgroup (all volumes vraid5 with sparing level 1 and almost no space left for more volumes, 1TiB drives) is being rebuilt with "spare space" right now, and it will take at least 15 hours to do the leveling/rebuilding. We can't get a new disk until Friday. So, the question is, what would happen if another disk dies before the leveling completes? Would we lose data? And after that, how many aditional disks could die before losing data? 1 or 2? In "usual" RAID, we would be vulnerable to data loss while the rebuild takes place, but in this case the space reserved for sparing is two times the size of the bigger disk, so at the very least the effect should be the same of having two spares. Thanks in advance. Update: I have found some interesting threads about this question but still can't answer to this question, so I'm starting a bounty. http://blog.thestoragearchitect.com/2008/10/27/understanding-eva/ http://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&url=http%3A%2F%2Fwww.experts-exchange.com%2FStorage%2FStorage_Technology%2FQ_25548177.html (Expert Exchange question from google).

    Read the article

  • Solid State Drive Occasionally Freezes For A Minute While OS Is "Beach Balling"

    - by Boris_yo
    Almost a month ago I bought Intel 330 128GB solid state drive, migrated my data with Intel branded limited-feature Acronis from old HDD to new SSD, optimized with Intel Toolbox and started using it. Occassionally I get close to 1 minute freezes while seeing operating system "beach balls" and animations still work, I can interact and click on something but nothing responds, nothing loads. Recently a couple of such freezes occurred in shorter amount of time in a row. I have noticed that if I stop interacting with laptop, the freeze lasts less time than if I was interacting with laptop. But the bigger problem is when freeze just does not end and computer keeps being stuck unlil it is more than half hour and I run out of patience to keep waiting and feeling I need to restart the system because I am not getting anywhere. Such freeze happened while laptop was cold booting into Windows 7. This is when freeze hang occurred and I had to restart, only later to be greeted with Windows recovery screen stating something about faiure of boot sector and asking to insert Windows repair CD. But after I restarted, Windows booted successfully and all was well. I have filmed video of freeze hang occurring in cold boot which you can see here (on video page look below for description): http://www.youtube.com/watch?v=8b7MQlcDTUs As I have mentioned in the beginning, the SSD is less than a month old but here is S.M.A.R.T statistics just in case (TRIM is enabled btw according to CrystalDiskInfo): I want to emphasize that this SSD is the only drive I have, yet it is working in RAID mode (it was enabled initially in BIOS by previous laptop's owner) on Intel Rapid Storage drivers. I am contemplating about switching to AHCI mode but want to be sure this won't cause data loss. Additionally, the stock firmware is the only firmware available currently, yet Intel does not respond to my posts in their community board. If anyone here has this SSD model or generally has experience with SSD drives, I would love to know your thoughts.

    Read the article

  • Recover data from a Thecus N4100 NAS jbod partition

    - by TimothyP
    I have a Thecus N4100 NAS wich had a 2TB drive in it configured as jbod partition. Later I tried adding a second drive to expand the available space. I added it to the jbod configuration but I did not get any extra space. Then I tried removing the second drive but then the NAS system indicated the jbod configuration was damaged. After a reboot it told me there is no configuration and I need to create a new RAID/jbod configuration and that I would lose all data on the drive. Of course I did not do this, I took the 2TB drive and checked with Linux if the partition was still there and it is... completely intact. I found that linux recognizes it as a /dev/mdX device and that I should be able to mount it but I don't know the file system type. Anyway.... is there a way to recover the data? Since everything has always been on a single drive it should all be there right? I can connect the drive to Windows , Linux or MacOS so whatever gets the job done.

    Read the article

  • Scaling databases with cheap SSD hard drives

    - by Dennis Kashkin
    Hey guys! I hope that many of you are working with high traffic database-driven websites, and chances are that your main scalability issues are in the database. I noticed a couple of things lately: Most large databases require a team of DBAs in order to scale. They constantly struggle with limitations of hard drives and end up with very expensive solutions (SANs or large RAIDs, frequent maintenance windows for defragging and repartitioning, etc.) The actual annual cost of maintaining such databases is in $100K-$1M range which is too steep for me :) Finally, we got several companies like Intel, Samsung, FusionIO, etc. that just started selling extremely fast yet affordable SSD hard drives based on SLC Flash technology. These drives are 100 times faster in random read/writes than the best spinning hard drives on the market (up to 50,000 random writes per second). Their seek time is pretty much zero, so the cost of random I/O is the same as sequential I/O, which is awesome for databases. These SSD drives cost around $10-$20 per gigabyte, and they are relatively small (64GB). So, there seems to be an opportunity to avoid the HUGE costs of scaling databases the traditional way by simply building a big enough RAID 5 array of SSD drives (which would cost only a few thousand dollars). Then we don't care if the database file is fragmented, and we can afford 100 times more disk writes per second without having to spread the database across 100 spindles. . Is anybody else interested in this? I've been testing a few SSD drives and can share my results. If anybody on this site has already solved their I/O bottleneck with SSDs, I would love to hear your war stories! PS. I know that there are plenty of expensive solutions out there that help with scalability, for example the time proven RAM-based SANs. I want to be clear that even $50K is too expensive for my project. I have to find a solution that costs no more than $10K and does not take much time to implement.

    Read the article

  • Using udev to create a character device based on a driver being loaded

    - by SteveCB
    I'm in the process of setting up RAID monitoring for a number of Dell servers that use the PERC 6i integrated card. We're using Nagios at present and the check_megasasctl plugin seems to fit the bill. However, the plugin relies upon the existence of: /dev/megaraid_sas_ioctl_node This device node doesn't exist by default, you have to create it by hand using something like: mknod /dev/megaraid_sas_ioctl_node c 253 0 Now, to make the existence of this device node persistent across reboots, I thought I could write a udev rule, but as usual, I'm missing something. I thought I could create a file such as /etc/udev/rules.d/10-local/rules that contained: DRIVER=="megasas" NAME="megaraid_sas_ioctl_node" MODE="0600" But this doesn't work - no device node after a reboot. Dmesg output indicates the megasas driver is loaded and functional: megasas: 00.00.04.01-RH1 Thu July 10 09:41:51 PST 2008 megasas: 0x1000:0x0060:0x1028:0x1f0c: bus 1:slot 0:func 0 megasas: FW now in Ready state Further, I don't see any means to instruct udev on which type of device node to create: character or block. I suspect I'm failing to understand exactly how udev is meant to work. I realise I could just cheat and run MegaCLI in /etc/rc.local, redirecting output to /dev/null; it creates the megaraid_sas_ioctl_node device node as part of its execution. I just thought using udev rules would be a) cleaner and b) a useful learning exercise. Perhaps I should just dump the above mknod command in /etc/rc.local... So how do I get udev to create the /dev/megaraid_sas_ioctl_node device node based on the presence of the megasas driver? Cheers Steve

    Read the article

  • Flash Backed Write Cache (FBWC) without capacitor pack

    - by Martyn
    I brought a HP Smart Array P410 controller and it is installed and working fine in a HP Prolient Microserver with 4 drives in two RAID 1 arrays. I didn’t realise however that it came without any cache so would only work by directly writing straight to the disk, and the performance was horrible. So I then brought the 512MB Flash Backed Write Cache (FBWC) memory module as I was under the impression that with FBWC I would not need a battery. I got this idea from a forum post. "What do you guys think of the choice between 'BBWC' (battery backed write cache) and 'FBWC' (flash backed write cache)? The flashed based ones use non-volitile memory so need no battery." After installing the cache module however the server pretty much won’t boot. The P410 has a flashing amber light on it, and from the manual that doesn’t sound good. I’ve managed to get to the on board BIOS once and even managed to get to boot to the HP Array Configuration Utility (ACU) CD once, but every other time the Server continuingly reboots once it get to the POST screen and reads ARRAY INITILIZING %%%. The one time I reached the ACU, it reported a problem with the Cache Module. To me, it seems like the cache module is faulty, however the supplier tells me “Do you have an FBWC battery pack, p/n 587324-001, because that is required for the cache to work. If you have it, please complete an RMA form and we'll send a replacement / credit.” Does this sound right to you? I’ve been ordering the parts from the US and I don’t want to spend $77 + $40 p&p on a battery, wait a week for the shipping to find the card is faulty, and I don’t want to send back a working card?

    Read the article

  • Why database partitioning didn't work? Extract from thedailywtf.com

    - by questzen
    Original link. http://thedailywtf.com/Articles/The-Certified-DBA.aspx. Article summary: The DBA suggests an approach involving rigorous partitioning, 10 partitions per disk (3 actual disks and 3 raid). The stats show that the performance is non-optimal. Then the DBA suggests an alternative of 1 partition per disk (with more added disks). This also fails. The sys-admin then sets up a single disk, single partition and saves the day. The size of disks was not mentioned but given today,s typical disk sizes (of the order of 100 GB), the partitions ; would be huge, it surprises me that a single disk with all partitions outperformed. Initially I suspect that the data was segregated and hence faster reads. But how come the performance didn't degrade as time went by with all the inserts and updates happening? Saw this on reddit, but the explanation was by far spindle/platter centered. There was no mention in the article about this. Is there any other reason? I can only guess that the tables were using a incorrect hash distribution causing non-uniform allocation across disks (wrong partitioning); this would increase fetch times. Any thoughts?

    Read the article

  • Would an array of SSD drives be able to succesfully substitute the system memory?

    - by Florin Mircea
    I watched a few videos trying to answer this. This video (youtube.com/watch?v=eULFf6F5Ri8) shows a bunch of guys stacking 24 SSD's reaching a peak of around 2GBps r/w. That's under the limit of the worst DDR3 in this list (memorybenchmark.net/write_ddr3_amd.html) - that shows DDR3 memory performance varying from 2.78 to 6.55 Gb per second, but that video is over 3 years old. This video (youtube.com/watch?v=27GmBzQWwP0) shows a more optimistic situation, but for PCI-E SSD drives: 5 drives peaking at around 4Gb. And this other video shows that stacking up more than 3 SSD's doesn't realistically offer a substantial added performance. This and the fact that in all benchmarks the drives act quite poorly when dealing with small files (5k file read/write averaging from 10MB to around 30-40MBps) as opposed to how native memory handles such files, seems to indicate a definite NO to this question. Also, the write life cycle is indeed limited and the drives might wear out quickly, as kindly pointed out by paddy. However, I wanted to get more opinions on this. Would it be possible to at least obtain current memory performance with SSD's in RAID 0? And if so, in what circumstances? I am assuming using this configuration with a Windows OS that has a memory pagefile resident to that stack of SSD's, thus making it very fast to work with.

    Read the article

  • Can a non-redundant RAID5 cause any serious problems (compared to RAID0)?

    - by leemes
    I used to have a three-disc RAID5 (mdadm) in my computer for personal media storage (music, videos, photos, programs, games, ...). It had three discs with 750 GB each, resulting in an array capacity of 1.5 TB. One day (one year ago), I needed one of those discs to install another operating system. I thought, I don't need the redundancy anymore since I backup the most important stuff (personal photos e.g.) on an external disc anyway. So I decided to remove one of the three discs without converting the RAID to RAID0 or even two separate discs, because I had no temporary storage (since one cannot simply convert the RAID5 to RAID0 AFAIK). So now, for about one year, I have a non-redundant RAID5 with 2 of 3 discs running. Sometimes, one of the discs has a defective contact at the power cable or something similar causing the drive to stop working temporarily (I don't know exactly what it is). Since it still works when rebooting the computer and in most cases by calling some mdadm commands, it wasn't that problematic. Note that the data is not very critical, since I still have a backup of the most important stuff. But in the last few weeks, one of the drives fails very frequently (every few hours), so it gets really annoying to manage this. My questions are: Is there any disadvantage (apart from the annoying management) of a non-redundant RAID5 (with one drive less than typical) over a RAID0? If I understand it correctly, both have no redundancy and the same capacity. On a temporary drive failure, I can restart the array in both cases, assuming that the drive itself still works after the failure. Can it happen that the drive contents alter on a drive failure, making the array inconsistent? If so, can I tell mdadm to check the array for failures (without a file system level checking tool)? Since the drive most probably only has a defective contact causing it to fail for a second only, can I tell mdadm to automatically restart the array, so I will not even notice the failure if no application wanted to access the file system during the failure?

    Read the article

  • file read performance degrades as number of files increases

    - by bfallik-bamboom
    We're observing poor file read IO results that we'd like to better understand. We can use fio to write 100 files with a sustained aggregate throughput of ~700MB/s. When we switch the test to read instead of write, the aggregate throughput is only ~55MB/s. The drop seems related to the number of files since the throughput for read and write are comparable for a single file then diverge proportionally as we increase the number of files. The test server has 24 CPU cores, 48GB of memory, and is running CentOS 6.0. The disk hardware is a RAID 6 array with 12 disks and a Dell H800 controller. This device is partitioned with ext4 using the default settings. Increasing the readahead (using blockdev) improves the read throughput significantly but it still doesn't match write speed. For instance, increasing the readahead from 128KB to 1M improved the read throughput to ~145MB/s. Is this a known performance issue in our OS/disk/filesystem configuration? If so, how can we tell? If not, what tools or tests can we use to further isolate the issue? Thanks.

    Read the article

  • Sonicwall VPN, Domain Controller Issues

    - by durilai
    I am trying to get the domain logon script to execute when I connect to VPN. I have a SonicWall 4060PRO, with the SonicOS Enhanced 4.2.0.0-10e. The VPN connects successfully, but the script does not execute. I am posting the log below, but I see two issues. The first is the inability to connect to domain. 2009/12/18 19:49:53:457 Information XXX.XXX.XXX.XXX NetGetDCName failed: Could not find domain controller for this domain. The second is the failure of the script. 2009/12/18 19:49:53:466 Warning XXX.XXX.XXX.XXX Failed to execute script file \DT-WIN7netlogondomain.bat, Last Error: The network name cannot be found.. I assume the second issue is caused because of the first, also on the second issue it seems to be trying to get the logon script from my local PC, not the server. Finally, the DC can be pinged and reached by its computer name once the VPN is connected. The shares that the script is tring to map can be mapped manually. Any help is appreciated. 2009/12/18 19:49:31:063 Information The connection "GroupVPN_0006B1030980" has been enabled. 2009/12/18 19:49:32:223 Information XXX.XXX.XXX.XXX Starting ISAKMP phase 1 negotiation. 2009/12/18 19:49:32:289 Information XXX.XXX.XXX.XXX Starting aggressive mode phase 1 exchange. 2009/12/18 19:49:32:289 Information XXX.XXX.XXX.XXX NAT Detected: Local host is behind a NAT device. 2009/12/18 19:49:32:289 Information XXX.XXX.XXX.XXX The SA lifetime for phase 1 is 28800 seconds. 2009/12/18 19:49:32:289 Information XXX.XXX.XXX.XXX Phase 1 has completed. 2009/12/18 19:49:32:336 Information XXX.XXX.XXX.XXX Received XAuth request. 2009/12/18 19:49:32:336 Information XXX.XXX.XXX.XXX XAuth has requested a username but one has not yet been specified. 2009/12/18 19:49:32:336 Information XXX.XXX.XXX.XXX Sending phase 1 delete. 2009/12/18 19:49:32:336 Information XXX.XXX.XXX.XXX User authentication information is needed to complete the connection. 2009/12/18 19:49:32:393 Information An incoming ISAKMP packet from XXX.XXX.XXX.XXX was ignored. 2009/12/18 19:49:36:962 Information XXX.XXX.XXX.XXX Starting ISAKMP phase 1 negotiation. 2009/12/18 19:49:37:036 Information XXX.XXX.XXX.XXX Starting aggressive mode phase 1 exchange. 2009/12/18 19:49:37:036 Information XXX.XXX.XXX.XXX NAT Detected: Local host is behind a NAT device. 2009/12/18 19:49:37:036 Information XXX.XXX.XXX.XXX The SA lifetime for phase 1 is 28800 seconds. 2009/12/18 19:49:37:036 Information XXX.XXX.XXX.XXX Phase 1 has completed. 2009/12/18 19:49:37:094 Information XXX.XXX.XXX.XXX Received XAuth request. 2009/12/18 19:49:37:100 Information XXX.XXX.XXX.XXX Sending XAuth reply. 2009/12/18 19:49:37:110 Information XXX.XXX.XXX.XXX Received initial contact notify. 2009/12/18 19:49:37:153 Information XXX.XXX.XXX.XXX Received XAuth status. 2009/12/18 19:49:37:154 Information XXX.XXX.XXX.XXX Sending XAuth acknowledgement. 2009/12/18 19:49:37:154 Information XXX.XXX.XXX.XXX User authentication has succeeded. 2009/12/18 19:49:37:247 Information XXX.XXX.XXX.XXX Received request for policy version. 2009/12/18 19:49:37:253 Information XXX.XXX.XXX.XXX Sending policy version reply. 2009/12/18 19:49:37:303 Information XXX.XXX.XXX.XXX Received policy change is not required. 2009/12/18 19:49:37:303 Information XXX.XXX.XXX.XXX Sending policy acknowledgement. 2009/12/18 19:49:37:303 Information XXX.XXX.XXX.XXX The configuration for the connection is up to date. 2009/12/18 19:49:37:377 Information XXX.XXX.XXX.XXX Starting ISAKMP phase 2 negotiation with 10.10.10.0/255.255.255.0:BOOTPC:BOOTPS:UDP. 2009/12/18 19:49:37:377 Information XXX.XXX.XXX.XXX Starting quick mode phase 2 exchange. 2009/12/18 19:49:37:472 Information XXX.XXX.XXX.XXX The SA lifetime for phase 2 is 28800 seconds. 2009/12/18 19:49:37:472 Information XXX.XXX.XXX.XXX Phase 2 with 10.10.10.0/255.255.255.0:BOOTPC:BOOTPS:UDP has completed. 2009/12/18 19:49:37:896 Information Renewing IP address for the virtual interface (00-60-73-4C-3F-45). 2009/12/18 19:49:40:189 Information The virtual interface has been added to the system with IP address 10.10.10.112. 2009/12/18 19:49:40:319 Information The system ARP cache has been flushed. 2009/12/18 19:49:40:576 Information XXX.XXX.XXX.XXX NetWkstaUserGetInfo returned: user: Dustin, logon domain: DT-WIN7, logon server: DT-WIN7 2009/12/18 19:49:53:457 Information XXX.XXX.XXX.XXX NetGetDCName failed: Could not find domain controller for this domain. 2009/12/18 19:49:53:457 Information XXX.XXX.XXX.XXX calling NetUserGetInfo: Server: , User: Dustin, level: 3 2009/12/18 19:49:53:460 Information XXX.XXX.XXX.XXX NetUserGetInfo returned: home dir: , remote dir: , logon script: 2009/12/18 19:49:53:466 Warning XXX.XXX.XXX.XXX Failed to execute script file \DT-WIN7netlogondomain.bat, Last Error: The network name cannot be found..

    Read the article

  • hp ProLiant DL380 G6 server error code: 347 of array controller

    - by alhaythum
    I have got a bran new hp ProLiant DL380 G6 server with embedded smart array P410i controller, I got 164 GB SATA drives and wanted to change them with 300 GB SATA drives before installation. Now, we replace the drives and begin the configuration with the hp DVD and begin; when we reach the point that we want to save the configurations, an error message appears: "The operation has failed with an unknown error, please restart the application and attempt the operation again" When using Rescan System, this error message appears: "Status Alerts - Smart Array P410i in Embedded Slot Warning Status Message Code Description 347 The cache for Smart Array P410i Embedded Slot is not configured" We return back to the 164 GB SATA drives and the message just keeps appearing again. Any help please.

    Read the article

  • Server 2012 AD-DS Setup Fails (Microsoft.Directory.Services.Deployment.DeepTasks.DeepTasks not found)

    - by Daniel Steiner
    Good Morning everyone, I am currently trying to promote my 2012 Server to a Domain Controller but when I am at the first step in the setup I get the Error Message (German, Original Message): [Bereitstellungskonfiguration] Fehler bei der Bestimmung, ob der Zielserver bereits ein Domänencontroller ist: Der Typ [Microsoft.Directory.Services.Deployment.DeepTasks.DeepTasks] wurde nicht gefunden: Vergewissern Sie sich, dass die Assembly, die diesen Typ enthält, geladen ist. (Translated to English): Error while determining, if the Targetserver already is a Domain Controller: The Type [Microsoft.Directory.Services.Deployment.DeepTasks.DeepTasks] was not found: Make sure, that the assembly, that contains this type, is loaded. Thus I can neither Configure the AD-DS nor deinstall them via Server Manager. Any Help how to fix that problem would be greatly appricieated.

    Read the article

< Previous Page | 60 61 62 63 64 65 66 67 68 69 70 71  | Next Page >