Search Results

Search found 11732 results on 470 pages for 'action extending'.

Page 7/470 | < Previous Page | 3 4 5 6 7 8 9 10 11 12 13 14  | Next Page >

  • Creating vCard action result

    - by DigiMortal
    I added support for vCards to one of my ASP.NET MVC applications. I worked vCard support out as very simple and intelligent solution that fits perfectly to ASP.NET MVC applications. In this posting I will show you how to send vCards out as response to ASP.NET MVC request. We need three things: some vCard class, vCard action result, controller method to test vCard action result. Everything is very simple, let’s get hands on. vCard class As first thing we need vCard class. Last year I introduced vCard class that supports also images. Let’s take this class because it is easy to use and some dirty work is already done for us. NB! Take a look at ASP.NET example in the blog posting referred above. We need it later when we close the topic. Now think about how useful blogging and information sharing with others can be. With this class available at public I saved pretty much time now. :) vCardResult As we have vCard it is now time to write action result that we can use in our controllers. Here’s the code. public class vCardResult : ActionResult {     private vCard _card;       protected vCardResult() { }       public vCardResult(vCard card)     {         _card = card;     }       public override void ExecuteResult(ControllerContext context)     {         var response = context.HttpContext.Response;         response.ContentType = "text/vcard";         response.AddHeader("Content-Disposition", "attachment; fileName=" + _card.FirstName + " " + _card.LastName + ".vcf");           var cardString = _card.ToString();         var inputEncoding = Encoding.Default;         var outputEncoding = Encoding.GetEncoding("windows-1257");         var cardBytes = inputEncoding.GetBytes(cardString);           var outputBytes = Encoding.Convert(inputEncoding,                                 outputEncoding, cardBytes);           response.OutputStream.Write(outputBytes, 0, outputBytes.Length);     } } And we are done. Some notes: vCard is sent to browser as downloadable file (user can save or open it with Outlook or any other e-mail client that supports vCards), File name is made of first and last name of contact. Encoding is important because Outlook may not understand vCards otherwise (don’t know if this problem is solved in Outlook 2010). Using vCardResult in controller Now let’s tale a look at simple controller method that accepts person ID and returns vCardResult. public class ContactsController : Controller {       // ... other controller methods ...       public vCardResult vCard(int id)     {         var person = _partyRepository.GetPersonById(id);         var card = new vCard                 {                     FirstName=person.FirstName,                     LastName = person.LastName,                     StreetAddress = person.StreetAddress,                     City = person.City,                     CountryName = person.Country.Name,                       Mobile = person.Mobile,                     Phone = person.Phone,                     Email = person.Email,                 };           return new vCardResult(card);     } } Now you can run Visual Studio and check out how your vCard is moving from your web application to your e-mail client. Conclusion We took old code that worked well with ASP.NET Forms and we divided it into action result and controller method that uses vCard as bridge between our controller and action result. All functionality is located where it should be and we did nothing complex. We wrote only couple of lines of very easy code to achieve our goal. Do you understand now why I love ASP.NET MVC? :)

    Read the article

  • Make ‘Associate’ the default checkin action

    When you associate a work item to a checkin, the work item will be resolved by default. Some teams have work items that are bigger then one checkin (although this is not recommended) and don’t want to resolve the work items during a checkin. The only ways to modify the behaviour are: - Remove the default checkin action from the work item type. Downside is that it is not possible in the UI to choose resolve if you actually want to resolve the work item. - Change the Resolve action to associate.   In Visual Studio 2010 you can modify this behaviour by changing a registry setting. Change value the following key to “False”. HKEY_CURRENT_USER\Software\Microsoft\VisualStudio\10.0\TeamFoundation\SourceControl\Behavior @ResolveAsDefaultCheckinAction

    Read the article

  • Doing two Declarative Operations with One Button

    - by shay.shmeltzer
    You can file the below video under "things that get asked on OTN a lot". With ADF it is very easy to drag an operation to a page to create a button that activate it. But what if you want a single button to invoke two operations? For example have a button that does a "Delete" as well as a "Commit". The way to do it is to add an action binding, and then overwrite the button function in a backing bean to call the additional action. The nice thing is that JDeveloper will create all the binding code for you in the backing bean - all you need to do is duplicate it. Here is a quick demo:

    Read the article

  • ASP.NET MVC in Action podcast with Deep-Fried Bytes crew

    Thanks to Keith and Woody for having us on their podcast.  It was a lot of fun.  The podcast is now published.  Here are the details. Episode 48: Web Development with ASP.NET MVC In Action Authors About This Episode In this episode Keith and Woody caught up with the team that wrote the book ASP.NET MVC In Action: Jeffrey Palermo, Ben Scheirman and Jimmy Bogard. The guys discussed the book, what drives their passion around ASP.NET MVC and what is in store for this huge change in...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Conditionan Action in SSRS

    - by Jesse
    I want my textbox to have an action ONLY if the condition is true, otherwise no action. This is what I have as my current action expression for going to another report: =IIf(Fields!MyTextbox.Value = "0", "Report2","") This does not produce my desired result. It gives the textbox an action regardless of the condition result. Is there a 'No Action' or 'Cancel Action' value?

    Read the article

  • Why can't I use an Action to a ThreadStart?

    - by Rookian
    Both are delegates and have the same signature, but I can not use Action as ThreadStart. Why? Action doIt; doIt = () => MyMethod("test"); Thread t; t = new Thread(doIt); t.Start(); but this seams to work: Thread t; t = new Thread(() => MyMethod("test")); t.Start();

    Read the article

  • Custom action getting published multiple times on user's timeline for same object

    - by serpent403
    I just noticed that when I publish an action on the user's timeline for the same object multiple times, using facebook's 'built-in' action type (eg: 'read' an article), i get an error response, something like "action is already associated to the user on this object". But when i try to do the same for a custom action that i created(eg: 'agreed' with an article), I don't get any error message, instead the actions gets published multiple times. I want my custom action to behave just like facebook's default action-type.

    Read the article

  • Problem playing repeat animation/action?

    - by Beast
    I'm calling this function on multiple sprites after checking numberOfRunningActions()"to play same animation but it's not working only the first tagged sprite plays the animation. What am I doing wrong? void CGame::playAnimation(const char* filename, int tag, CCLayer* target) { CCAnimation* animation = CCAnimation::animation(); CCSprite* spriteSheet = CCSprite::spriteWithFile(filename); for(int i = 0; i < spriteSheet->getTexture()->getPixelsWide()/SIZE; i++) // SIZE is an int value { animation->addFrameWithTexture(spriteSheet->getTexture(), CCRect(SIZE * i, 0, SIZE, SIZE)); } CCActionInterval* action = CCAnimate::actionWithDuration(1, animation, true); CCRepeatForever* repeatAction = CCRepeatForever::actionWithAction(action); target->getChildByTag(tag)->runAction(repeatAction); }

    Read the article

  • Zend Partial + Zend Action Helper causes an additional request to bootstrap?

    - by AndreLiem
    I've been profiling some zend framework code with webgrind to see where some bottle necks are and I'm noticing some very odd behavior. Using the zend partial for example, if I pass a variable value that comes from a zend action helper, it results in two requests being made. in sample.phtml echo $this->partial('partial/embed.phtml', array('url' => $this->url)); in indexcontroller.php $this->view->url = $this->_helper->Embed()->url; But if I don't pass the value from the helper to the partial, but still run the helper, it only makes one request in webgrind. e.g. $this->view->url = 'test'; $this->_helper->Embed()->url; Does anybody know why this could be happening? Am I potentially interpreting web grind incorrectly, or is it really calling the bootstrap twice when the an action helper value is tied to a partial? I'm starting to realize how inefficient some components of Zend are. Thanks

    Read the article

  • Action button: only true once per press

    - by Sidar
    I'm using SFML2.0 and am trying to make a wrapper class for my controller/joystick. I read all the input data from my controller and send it off to my controllable object. I want to have two types of buttons per button press, one that is continues(true false state ) and one that is an action and is set to false after the next frame update. Here is an example of how I set my button A to true or false with the SFML api. Whereas data is my struct of buttons, and A holds my true/false state every update. data.A = sf::Joystick::isButtonPressed(i,st::input::A); But I've also added "data.actionA" which represents the one time action state. Basically what I want is for actionA to be set false after the update its been set to true. I'm trying to keep track of the previous state. But I seem to fall into this loop where it toggles between true and false every update. Anyone an idea? Edit: Since I can't answer my own question yet here is my solution: data.actionA = data.A = sf::Joystick::isButtonPressed(i,st::input::A); if(prev.A) data.actionA = false; First I always set the actionA to the value of the button state. Then I check if the previous state of A is true. If so we negate the value.

    Read the article

  • SATA errors reported during boot: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0

    - by digby280
    I have noticed some error during the Linux boot. They seem to continue to occur after the boot adding lines to the log every few seconds. Once booted this normally does not appear to be causing any problems. However, around 1 in 10 boots results in a kernel panic and the computer has on two or three occasions suddenly rebooted after being powered on for a number of hours. I presume the cause of the reboot is a kernel panic as well. I am running Ubuntu 11.10 and I have had Ubuntu installed on the computer for around a year. I have googled around and not found anything useful. I have provided the kernel log lines and the output of smartctl. Can anyone explain exactly what these errors mean, or better still how to resolve them? Apr 2 16:51:27 dell580 kernel: [ 19.831140] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:27 dell580 kernel: [ 19.934194] tg3 0000:03:00.0: eth0: Link is down Apr 2 16:51:28 dell580 kernel: [ 20.929468] tg3 0000:03:00.0: eth0: Link is up at 100 Mbps, full duplex Apr 2 16:51:28 dell580 kernel: [ 20.929471] tg3 0000:03:00.0: eth0: Flow control is on for TX and on for RX Apr 2 16:51:28 dell580 kernel: [ 20.929727] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready Apr 2 16:51:29 dell580 kernel: [ 21.609381] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:29 dell580 kernel: [ 21.616515] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:29 dell580 kernel: [ 21.616519] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:29 dell580 kernel: [ 21.616525] ata2.00: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 21.934036] ata2.01: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 22.408890] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.408907] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.440934] ata2.00: configured for UDMA/100 Apr 2 16:51:29 dell580 kernel: [ 22.449040] ata2.01: configured for UDMA/133 Apr 2 16:51:29 dell580 kernel: [ 22.449818] ata2: EH complete Apr 2 16:51:33 dell580 kernel: [ 26.122664] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:33 dell580 kernel: [ 26.122670] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:33 dell580 kernel: [ 26.122677] ata2.00: hard resetting link Apr 2 16:51:33 dell580 kernel: [ 26.442684] ata2.01: hard resetting link Apr 2 16:51:34 dell580 kernel: [ 26.925545] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.925561] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.961542] ata2.00: configured for UDMA/100 Apr 2 16:51:34 dell580 kernel: [ 26.969616] ata2.01: configured for UDMA/133 Apr 2 16:51:34 dell580 kernel: [ 26.970400] ata2: EH complete Apr 2 16:51:35 dell580 kernel: [ 28.111180] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:35 dell580 kernel: [ 28.111184] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:35 dell580 kernel: [ 28.111191] ata2.00: hard resetting link Apr 2 16:51:35 dell580 kernel: [ 28.429674] ata2.01: hard resetting link Apr 2 16:51:36 dell580 kernel: [ 28.904557] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.904572] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.936609] ata2.00: configured for UDMA/100 Apr 2 16:51:36 dell580 kernel: [ 28.944692] ata2.01: configured for UDMA/133 Apr 2 16:51:36 dell580 kernel: [ 28.945464] ata2: EH complete Apr 2 16:51:38 dell580 kernel: [ 31.581756] eth0: no IPv6 routers present Apr 2 16:51:38 dell580 kernel: [ 32.103066] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:38 dell580 kernel: [ 32.103074] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:38 dell580 kernel: [ 32.103085] ata2.00: hard resetting link Apr 2 16:51:38 dell580 kernel: [ 32.419669] ata2.01: hard resetting link Apr 2 16:51:39 dell580 kernel: [ 32.894518] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.894533] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.926536] ata2.00: configured for UDMA/100 Apr 2 16:51:39 dell580 kernel: [ 32.934715] ata2.01: configured for UDMA/133 Apr 2 16:51:39 dell580 kernel: [ 32.935578] ata2: EH complete Here's the output of smartctl for the drive. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.0.0-17-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT Device Model: SAMSUNG HD103UJ Serial Number: S13PJ90QC19706 LU WWN Device Id: 5 0000f0 00b1c7960 Firmware Version: 1AA01113 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3b Local Time is: Mon Apr 2 17:13:48 2012 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 41) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: (11772) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 197) minutes. Conveyance self-test routine recommended polling time: ( 21) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 076 076 011 Pre-fail Always - 7940 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 521 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 642 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 482 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 759 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 073 069 000 Old_age Always - 27 (Min/Max 16/27) 194 Temperature_Celsius 0x0022 073 067 000 Old_age Always - 27 (Min/Max 16/28) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 320028 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 099 099 000 Old_age Always - 1494 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 211 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 211 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 0f 31 63 8f e1 Error: ICRC, ABRT 15 sectors at LBA = 0x018f6331 = 26174257 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 40 62 8f e1 08 00:01:00.460 READ DMA c8 00 20 00 7c 30 e0 08 00:01:00.450 READ DMA c8 00 00 10 49 8f e1 08 00:01:00.440 READ DMA c8 00 e0 20 d0 30 e0 08 00:01:00.420 READ DMA c8 00 00 c0 59 90 e1 08 00:01:00.400 READ DMA Error 210 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 cf e9 cf 66 e0 Error: ICRC, ABRT 207 sectors at LBA = 0x0066cfe9 = 6737897 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 b8 cf 66 e0 08 00:08:29.780 READ DMA c8 00 60 60 c9 18 e0 08 00:08:29.770 READ DMA c8 00 40 20 c9 18 e0 08 00:08:29.770 READ DMA c8 00 20 00 c9 18 e0 08 00:08:29.760 READ DMA c8 00 20 98 cf 66 e0 08 00:08:29.750 READ DMA Error 209 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 2f d1 74 e0 e0 Error: ICRC, ABRT 47 sectors at LBA = 0x00e074d1 = 14709969 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 00 74 e0 e0 08 00:00:30.940 READ DMA c8 00 20 18 36 de e0 08 00:00:30.930 READ DMA c8 00 08 48 f1 dd e0 08 00:00:30.930 READ DMA c8 00 08 a8 f0 dd e0 08 00:00:30.930 READ DMA c8 00 08 90 f0 dd e0 08 00:00:30.930 READ DMA Error 208 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 7f 21 88 9d e0 Error: ICRC, ABRT 127 sectors at LBA = 0x009d8821 = 10324001 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 a0 00 88 9d e0 08 00:00:27.610 READ DMA c8 00 58 a8 e7 9c e0 08 00:00:27.610 READ DMA c8 00 00 28 e6 9c e0 08 00:00:27.610 READ DMA c8 00 00 e0 e4 9c e0 08 00:00:27.610 READ DMA c8 00 00 90 e0 9c e0 08 00:00:27.600 READ DMA Error 207 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 26 6a 6a c3 e0 Error: ABRT at LBA = 0x00c36a6a = 12806762 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- ca 00 00 90 69 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 68 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 50 65 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 d0 64 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 63 c3 e0 08 00:29:39.350 WRITE DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Interrupted (host reset) 90% 638 - # 2 Short offline Interrupted (host reset) 90% 638 - # 3 Extended offline Interrupted (host reset) 90% 638 - # 4 Short offline Interrupted (host reset) 90% 638 - # 5 Extended offline Interrupted (host reset) 90% 638 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • How to declare a Generics Action in struts2.xml file ?

    - by Rasatavohary
    Hi everyone, My problems is in a Struts2 action, where I have a class : public class MyAction<T> extends ActionSupport with a private member like this : private T myData; And I would like to declare this aciton in the struts.xml file, how can i manage to do so ? Thanks for the answer. Ps : I've tried without declaration of T, but it did not work

    Read the article

  • How can a wix custom action dll call be made to use the debug runtime via a merge module?

    - by Benj
    I'm trying to create a debug build with a corresponding debug installer for our product. I'm new to Wix so please forgive any naivety contained herein. The debug Dlls in my project are dependent on both the VS2008 and the VS2008SP1 debug runtimes. I've created a merge module feature in wix to bundle those runtimes with my installer. <Include xmlns="http://schemas.microsoft.com/wix/2006/wi"> <!-- Include our 'variables' file --> <!--<?include variables.wxi ?>--> <!--<Fragment>--> <DirectoryRef Id="TARGETDIR"> <!-- Always install the 32 bit ATL/CRT libraries, but only install the 64 bit ones on a 64 bit build --> <Merge Id="AtlFiles_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_ATL_x86.msm" DiskId="1" Language="1033"/> <Merge Id="AtlPolicy_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_ATL_x86.msm" DiskId="1" Language="1033"/> <Merge Id="CrtFiles_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugCRT_x86.msm" DiskId="1" Language="1033"/> <Merge Id="CrtPolicy_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugCRT_x86.msm" DiskId="1" Language="1033"/> <Merge Id="MfcFiles_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugMFC_x86.msm" DiskId="1" Language="1033"/> <Merge Id="MfcPolicy_x86" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugMFC_x86.msm" DiskId="1" Language="1033"/> <!-- If this is a 64 bit build, install the relevant modules --> <?if $(env.Platform) = "x64" ?> <Merge Id="AtlFiles_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_ATL_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="AtlPolicy_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_ATL_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="CrtFiles_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugCRT_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="CrtPolicy_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugCRT_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="MfcFiles_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\Microsoft_VC90_DebugMFC_x86_x64.msm" DiskId="1" Language="1033"/> <Merge Id="MfcPolicy_x64" SourceFile="$(env.CommonProgramFiles)\Merge Modules\policy_9_0_Microsoft_VC90_DebugMFC_x86_x64.msm" DiskId="1" Language="1033"/> <?endif?> </DirectoryRef> <Feature Id="MS2008_SP1_DbgRuntime" Title="VC2008 Debug Runtimes" AllowAdvertise="no" Display="hidden" Level="1"> <!-- 32 bit libraries --> <MergeRef Id="AtlFiles_x86"/> <MergeRef Id="AtlPolicy_x86"/> <MergeRef Id="CrtFiles_x86"/> <MergeRef Id="CrtPolicy_x86"/> <MergeRef Id="MfcFiles_x86"/> <MergeRef Id="MfcPolicy_x86"/> <!-- 64 bit libraries --> <?if $(env.Platform) = "x64" ?> <MergeRef Id="AtlFiles_x64"/> <MergeRef Id="AtlPolicy_x64"/> <MergeRef Id="CrtFiles_x64"/> <MergeRef Id="CrtPolicy_x64"/> <MergeRef Id="MfcFiles_x64"/> <MergeRef Id="MfcPolicy_x64"/> <?endif?> </Feature> <!--</Fragment>--> </Include> If I'm doing a debug build of the installer, I include that feature like so: <!-- The 'Feature' that contains the debug CRT/ATL libraries --> <?if $(var.Configuration) = "Debug"?> <?include ..\includes\MS2008_SP1_DbgRuntime.wxi?> <?endif?> The only problem is that my installer also includes a custom action which is also dependent on the debug runtime: <!-- Private key installer --> <Binary Id="InstallPrivateKey" SourceFile="..\InstallPrivateKey\win32\$(var.Configuration)\InstallPrivateKey.dll"></Binary> <CustomAction Id='InstallKey' BinaryKey='InstallPrivateKey' DllEntry='InstallPrivateKey'/> So how can I package the debug run time in such a way that the custom action also has access to it?

    Read the article

  • Oracle WebCenter in Action: Best Practices from Oracle Consulting

    - by Kellsey Ruppel
    Oracle WebCenter in Action: Best Practices from Oracle ConsultingSee concrete, real-world examples of deployments throughout the Oracle WebCenter stack. Oracle Consulting will lead you through a discussion about best practices and key customer use cases, as well as offer practical tips to support web experience management, enterprise content management, and portal deployments.Watch this webcast as our presenters discuss: Best practices for deployments of large complex architectures with Oracle WebCenter Sites Key deployments and helpful hints for Oracle WebCenter Content Performance tuning takeaways when using Oracle WebCenter Portal Watch the webcast by registering now. REGISTER NOW

    Read the article

  • I installed the Nautilus Actions Configuration utility but I don't have the action configuration menu option

    - by userman
    I am tyring to set up my trash to securely delete items and I am following the instructions on this page. http://techthrob.com/2010/07/07/adding-a-secure-delete-option-to-nautilus-file-manager-in-linux/ I installed the Nautilus Actions Configuration utility and according to the previously listed page a new action configuration menu option should have shown up in the Nautilus preferences menu. It didn't. Any help would be appreciated. Thanks!

    Read the article

  • Savable in Widget Lookup on Move Action

    - by Geertjan
    Possible from 7.3 onwards, since Widget now implements Lookup.Provider for the first time: import java.awt.Point; import java.io.IOException; import org.netbeans.api.visual.action.ActionFactory; import org.netbeans.api.visual.action.MoveProvider; import org.netbeans.api.visual.widget.LabelWidget; import org.netbeans.api.visual.widget.Scene; import org.netbeans.api.visual.widget.Widget; import org.netbeans.spi.actions.AbstractSavable; import org.openide.util.Lookup; import org.openide.util.lookup.AbstractLookup; import org.openide.util.lookup.InstanceContent; import org.openide.windows.TopComponent; public class MyWidget extends LabelWidget { private MySavable mySavable; private Lookup lookup; private TopComponent tc; private InstanceContent ic; public MyWidget(Scene scene, String label, TopComponent tc) { super(scene, label); this.tc = tc; ic = new InstanceContent(); getActions().addAction(ActionFactory.createMoveAction(null, new MoveStrategyProvider())); } @Override public Lookup getLookup() { if (lookup == null) { lookup = new AbstractLookup(ic); } return lookup; } private class MoveStrategyProvider implements MoveProvider { @Override public void movementStarted(Widget widget) { } @Override public void movementFinished(Widget widget) { modify(); } @Override public Point getOriginalLocation(Widget widget) { return ActionFactory.createDefaultMoveProvider().getOriginalLocation(widget); } @Override public void setNewLocation(Widget widget, Point point) { ActionFactory.createDefaultMoveProvider().setNewLocation(widget, point); } } private void modify() { if (getLookup().lookup(MySavable.class) == null) { ic.add(mySavable = new MySavable()); } } private class MySavable extends AbstractSavable { public MySavable() { register(); } TopComponent tc() { return tc; } @Override protected String findDisplayName() { return getLabel(); } @Override protected void handleSave() throws IOException { ic.remove(mySavable); unregister(); } @Override public boolean equals(Object obj) { if (obj instanceof MySavable) { MySavable m = (MySavable) obj; return tc() == m.tc(); } return false; } @Override public int hashCode() { return tc().hashCode(); } } }

    Read the article

  • Nautilus-Action conf. tool - crafting a "set as background" action

    - by EgyptBeast
    I wanted to create an option in the context menu to set the clicked picture to current desktop background (just like in Windows). I read the the nautilus action help but I couldn't figure it out. This is by far the command I could craft: gsettings set org.gnome.desktop.background picture-uri file://$PWD/ What I need: A command that correctly sets the current image to be the desktop background This command should only appear to the proper files (picture extenstions like .jpg)

    Read the article

  • Follow the action: OTN's YouTube Channel

    - by Bob Rhubart
    If you're not one of the 50,000 people participating in Oracle OpenWorld in San Francisco next week you can still be a part of the action. Members of the OTN crew will be interviewing various community luminaries and subject matter experts and capturing some of the color and exitement on video. These videos will be posted on the Oracle Technology Network YouTube Channel daily.  Of course, you can also keep tabs on what's happening through social media via OTN's Facebook and Twitter (@oracletechnet) channels. Stay tuned...

    Read the article

< Previous Page | 3 4 5 6 7 8 9 10 11 12 13 14  | Next Page >