  • Generating CMakeLists.txt

    - by vanna
    I got a bunch of C++ sources files and headers. They may use external libraries such as Boost e.g. I am interested in the process of building binaries for Windows and *nix. Makefiles (*nix) and .vcproj (Windows) call compilers with some specifications such as the order of compilation, compilation options and stuff. CMakeLists.txt can be used by CMake to build either makefiles or .vcproj and use very helpful commands such as recursive search of files, automatic linkage with known libraries, installers, variables that can be used in source files... Is there any existing tool that would generate a CMakeLists.txt from specified options ? Options could be like : scan this folder and make a library out of it, then scan this other folder and make an executable and automatically link both with Boost as well along with a user friendly installer with generated INSTALL.txt and README.txt. Something very powerful like that.

    Read the article

  • Architecture for Qt SIGNAL with subclass-specific, templated argument type

    - by Barry Wark
    I am developing a scientific data acquisition application using Qt. Since I'm not a deep expert in Qt, I'd like some architecture advise from the community on the following problem: The application supports several hardware acquisition interfaces but I would like to provide an common API on top of those interfaces. Each interface has a sample data type and a units for its data. So I'm representing a vector of samples from each device as a std::vector of Boost.Units quantities (i.e. std::vector<boost::units::quantity<unit,sample_type> >). I'd like to use a multi-cast style architecture, where each data source broadcasts newly received data to 1 or more interested parties. Qt's Signal/Slot mechanism is an obvious fit for this style. So, I'd like each data source to emit a signal like typedef std::vector<boost::units::quantity<unit,sample_type> > SampleVector signals: void samplesAcquired(SampleVector sampleVector); for the unit and sample_type appropriate for that device. Since tempalted QObject subclasses aren't supported by the meta-object compiler, there doesn't seem to be a way to have a (tempalted) base class for all data sources which defines the samplesAcquired Signal. In other words, the following won't work: template<T,U> //sample type and units class DataSource : public QObject { Q_OBJECT ... public: typedef std::vector<boost::units::quantity<U,T> > SampleVector signals: void samplesAcquired(SampleVector sampleVector); }; The best option I've been able to come up with is a two-layered approach: template<T,U> //sample type and units class IAcquiredSamples { public: typedef std::vector<boost::units::quantity<U,T> > SampleVector virtual shared_ptr<SampleVector> acquiredData(TimeStamp ts, unsigned long nsamples); }; class DataSource : public QObject { ... signals: void samplesAcquired(TimeStamp ts, unsigned long nsamples); }; The samplesAcquired signal now gives a timestamp and number of samples for the acquisition and clients must use the IAcquiredSamples API to retrieve those samples. Obviously data sources must subclass both DataSource and IAcquiredSamples. The disadvantage of this approach appears to be a loss of simplicity in the API... it would be much nicer if clients could get the acquired samples in the Slot connected. Being able to use Qt's queued connections would also make threading issues easier instead of having to manage them in the acquiredData method within each subclass. One other possibility, is to use a QVariant argument. This necessarily puts the onus on subclass to register their particular sample vector type with Q_REGISTER_METATYPE/qRegisterMetaType. Not really a big deal. Clients of the base class however, will have no way of knowing what type the QVariant value type is, unless a tag struct is also passed with the signal. I consider this solution at least as convoluted as the one above, as it forces clients of the abstract base class API to deal with some of the gnarlier aspects of type system. So, is there a way to achieve the templated signal parameter? Is there a better architecture than the one I've proposed?

    Read the article

  • Why does my finite state machine take so long to execute?

    - by BillyONeal
    Hello all :) I'm working on a state machine which is supposed to extract function calls of the form /* I am a comment */ //I am a comment perf("this.is.a.string.which\"can have QUOTES\"", 123456); where the extracted data would be perf("this.is.a.string.which\"can have QUOTES\"", 123456); from a file. Currently, to process a 41kb file, this process is taking close to a minute and a half. Is there something I'm seriously misunderstanding here about this finite state machine? #include <boost/algorithm/string.hpp> std::vector<std::string> Foo() { std::string fileData; //Fill filedata with the contents of a file std::vector<std::string> results; std::string::iterator begin = fileData.begin(); std::string::iterator end = fileData.end(); std::string::iterator stateZeroFoundLocation = fileData.begin(); std::size_t state = 0; for(; begin < end; begin++) { switch (state) { case 0: if (boost::starts_with(boost::make_iterator_range(begin, end), "pref(")) { stateZeroFoundLocation = begin; begin += 4; state = 2; } else if (*begin == '/') state = 1; break; case 1: state = 0; switch (*begin) { case '*': begin = boost::find_first(boost::make_iterator_range(begin, end), "*/").end(); break; case '/': begin = std::find(begin, end, L'\n'); } break; case 2: if (*begin == '"') state = 3; break; case 3: switch(*begin) { case '\\': state = 4; break; case '"': state = 5; } break; case 4: state = 3; break; case 5: if (*begin == ',') state = 6; break; case 6: if (*begin != ' ') state = 7; break; case 7: switch(*begin) { case '"': state = 8; break; default: state = 10; break; } break; case 8: switch(*begin) { case '\\': state = 9; break; case '"': state = 10; } break; case 9: state = 8; break; case 10: if (*begin == ')') state = 11; break; case 11: if (*begin == ';') state = 12; break; case 12: state = 0; results.push_back(std::string(stateZeroFoundLocation, begin)); }; } return results; } Billy3

    Read the article

  • Modify registry for Internet Connection Sharing?

    - by Tim
    My OS is Windows XP. Quoted from How to Change the IP Range for the Internet Connection Sharing DHCP service Use Registry Editor to modify the data value of the IntranetInfo value in the following registry key: Hkey_Local_Machine\System\CurrentControlSet\Services\ICSharing\Settings\General The first number listed is the IP address of the internal IP address of the Connection Sharing host. The second number is the subnet IP address separated by a comma. Enter the first IP address of the new range followed by the subnet mask, separated by a comma. (For example, 169.254.0.1,255.255.0.0.). Modify the data value of the Start value in the following registry key: Hkey_Local_Machine\System\CurrentControlSet\Services\ICSharing\Addressing\Settings Change the value to the second address of the selected IP range. This address cannot be the same or a lower value than the IP address used for the IntranetInfo key. Modify the data value for the Stop value in the same registry key. Enter the last the IP address of the selected IP range. My registry table does not have Hkey_Local_Machine\System\CurrentControlSet\Services\ICSharing, and I don't know how to do with my registry table following the above three steps. Can someone guide me through it step by step?

    Read the article

  • missing network usage through iptables

    - by Purres
    I inserted a rule to iptables to track the input usage to a certain ip address. The vps server's IP is 192.168.1.5 and the guest os's IP is 192.168.1.115. I ran 'yum update' inside the guest OS to get some network traffic. Then I ran iptables -vnL from the hypervisor. However it only showed network usage to the host, but not to the guest. Chain INPUT (policy ACCEPT 0 packets, 0 bytes) pkts bytes target source destination 0 0 0.0.0.0/0 0.0.0.0/0 destination IP range 192.168.1.115-192.168.1.115 1853 114K 0.0.0.0/0 0.0.0.0/0 destination IP range 192.168.1.5-192.168.1.5 I ran tcpdump and the log showed that there're data packets to the guest os. 16:17:43.932514 IP mirrordenver.fdcservers.net.http > 192.168.1.115.34471: Flags [.], seq 17694667:17696115, ack 1345, win 113, options [nop,nop,TS val 1060308643 ecr 1958781], length 1448 16:17:43.932559 IP 192.168.1.115.34471 > mirrordenver.fdcservers.net.http: Flags [.], ack 17696115, win 15287, options [nop,nop,TS val 1958869 ecr 1060308643], length 0 Why the guest OS network usage couldn't be tracked? iptables -L will return the INPUT chain as following: Chain INPUT (policy ACCEPT) target prot opt source destination all -- anywhere anywhere destination IP range 192.168.1.115-192.168.1.115 all -- anywhere anywhere destination IP range 192.168.1.5-192.168.1.5 all -- anywhere anywhere

    Read the article

  • Windows 7 VPN Error 619

    - by TravisPUK
    So I am running Windows 7 Enterprise. This morning I was able to VPN using the built in VPN (Connect to Work Network etc). I had to change my network's IP address range and now the VPN will not work. It just stalls on the Verifying user name and password... message. But then it returns the 619 error. Anybody know why changing my machine's IP address would cause this problem? Where should I be looking to try and fix this issue? I have tried this on a Windows XP machine that also had the IP address range change and this still connects fine using exactly the same connection details. EDIT The internal network range changed from 192.x.x.x to 10.x.x.x. This was done on the entire Active Directory. All machines are running fine and the Windows XP machine, that works going to the same client VPN mentioned above is on the same network. Both the XP and the Win 7 machines are using DHCP served by the Domain Controller. The client domain is not performing any IP range checks/restrictions. The VPN is outside the internal network, connection is being made via the Internet and not passing through any other machine, other than the normal domain machines, ie DNS etc. This is passing through a router and the router has the relevant VPN passthrough options configured. All internal machines are working correctly with other forms of VPN, ie Cisco, Sonic etc (these were tested on other machines, they are not installed on the Vista or Win7 machines). After further testing, this is occurring on all Win7 and Vista machines where they can no longer connect to the client VPN, however all XP machines can still connect fine. This has been tested on three Vista, two Win7 and five XP machines. All machines are on DHCP and tests have been done with both the firewalls turned on and off, as well as with fixed IPs being used. Thanks Travis

    Read the article

  • CPU operating temperature ranges

    - by osij2is
    I have an AMD Phenom II 960T with 2 cores unlocked for a total of 6 cores. I don't overclock at all. I have a Arctic Cooling ACALP64 Heatsink/Fan installed. I'm currently running ESXi 5.0 so I have to go into the BIOS to read the CPU temperatures, which at idle seem to be in the 71-74C range. To me, this is pretty high, but I cannot find any official temperature ranges that AMD says the CPU can work well within. There seems to be a lot of questions on superuser and numerous forums around CPU temperatures but no one seems to have a clear consensus as to what the manufacturer temperature ranges are for specific CPUs. I've tried searching through AMDs site to no avail. At this point, I'd be willing to shut off the 2 extra cores if it keeps the heat down but until I get some sort of tolerance or range for temperature, I have no idea if the CPU is being damaged or not. Can anyone point to a direct source, article, FAQ from AMD that specifically states their CPUs temperature range? Or are CPU temperature ranges so varying that there's no possible baseline? Am I being too paranoid about this? To me, anything over 65C is a bit much and if I'm in the low-mid 70s range with NO VMs running, what can I expect if I have several VMs running?

    Read the article

  • How do you link a time stamp to a cell using a userform button control? [migrated]

    - by Chad Cochrane
    Hello fellow VB Developers/Users/Hobbyists/What-Have-You! I have a user form that has two buttons: 1. Start 2. Stop When I press start, I would like it to record the current time with this format: (dd/mm/yy hh:nn:ss:) in a specific column. Then when I press the Stop Button I would like it to record the time again in the cell next to it. Then if I press start Again I would like it to record below the first cells current record. Basically I am building a timer to record data to see how long certain tasks take. I will post the excel file and provide more information were necessary. Thanks for any help provided. CURRENT CODE Public runTimer As Double Public startTime As Date Dim counter As Date Sub setStart() counter = 0 startTime = Now runTimer = Now + TimeSerial(0, 0, 1) Application.OnTime runTimer, "setStart", , True Set myTime = Sheet4.Range("F1") Set timeRng = Sheet4.Range("C8:C100") i = WorksheetFunction.CountA(timeRng) i = i + 1 Cells(i, "C") = myTime Sheet4.Cells(i, "C").NumberFormat = "yyyy/mm/dd HH:mm:ss" If i >= 2 Then Cells(i, "D8") = Cells(i, "C8") - Cells(i - 1, "C8") Sheet4.Cells(i, "C").NumberFormat = "yyyy/mm/dd HH:mm:ss" End If Application.EnableEvents = False End Sub Sub setStop() Application.OnTime runTimer, "setStop", , True Set myTime = Sheet4.Range("F1") Set timeRng = Sheet4.Range("D8:D100") i = WorksheetFunction.CountA(timeRng) i = i + 1 Application.EnableEvents = False Cells(i, "D") = myTime Sheet4.Cells(i, "D").NumberFormat = "yyyy/mm/dd HH:mm:ss" End Sub

    Read the article

  • UIDs for service users in Mac OS X

    - by LaC
    Some third-party servers should be run under a special user for security reasons (eg, PostgreSQL is typically run by "postgres"). Of course, these service users should not show up in the Mac OS X login windows. I know how to create hidden users using dscl or dsimport, but I'm wondering what the best policy is for assigning UIDs (and matching GIDs). Apple's documentation states that UIDs from 0 to 100 are reserved (pg. 69), but OS X comes with several special users and groups outside that range. I used to use ids from 401 onwards for services, but I noticed that OS X 10.6 has started using that range for groups created by the Sharing pane in System Preferences. What is the recommended ID range to use for third-party services, then? Perhaps I should just use IDs in the 500 range, since all that is needed to hide a user in Snow Leopard is setting his password to "*"? Also, most of Apple's services have names starting with an underscore, with an alias sans underscore; eg, _sandbox and sandbox. Is there any special significance to this? Should I do the same for my services?

    Read the article

  • Prevent 'Run-time error '7' out of memory' error in Excel when using macro

    - by MasterJedi
    I keep getting this error whenever I run a macro in my excel file. Is there any way I can prevent this? My code is below. Debugging highlights the following line as the issue: ActiveSheet.Shapes.SelectAll My macro: Private Sub Save() Dim sh As Worksheet ActiveWorkbook.Sheets("Report").Copy 'Create new workbook with Sheets("Report"(2)) as only sheet. Set sh = ActiveWorkbook.Sheets(1) 'Set the new sheet to a variable. New workbook is now active workbook. sh.Name = sh.Range("B9") & "_" & Format(Date, "mmyyyy") 'Rename the new sheet to B9 value + date. With sh.UsedRange.Cells .Value = .Value 'eliminate all formulas .Validation.Delete 'remove all validation .FormatConditions.Delete 'remove all conditional formatting ActiveSheet.Buttons.Delete ActiveSheet.Shapes.SelectAll Selection.Delete lrow = Range("I" & Rows.Count).End(xlUp).Row 'select rows from bottom up to last containing data in column I Rows(lrow + 1 & ":" & Rows.Count).Delete 'delete rows with no data in column I Application.ScreenUpdating = False .Range("A410:XFD1048576").Delete Shift:=xlUp 'delete all cells outwith report range Application.ScreenUpdating = True Dim counter Dim nameCount nameCount = ActiveWorkbook.Names.Count counter = nameCount Do While counter > 0 ActiveWorkbook.Names(counter).Delete counter = counter - 1 Loop 'remove named ranges from workbook End With ActiveWorkbook.SaveAs "\\Marko\Report\" & sh.Name & ".xlsx" 'Save new workbook using same name as new sheet. ActiveWorkbook.Close False 'Close the new workbook. MsgBox ("Export complete. Choose the next ADP in cell B9 and click 'Calculate'.") 'Display message box to inform user that report has been saved. End Sub Not sure how to make this more efficient or to prevent this error.

    Read the article

  • Getting Run time 1004 error in code

    - by krishna123
    I tried the code provided by vba express for combining sheet, while execution it is displaying Run Time error 1004: Application Defined or Object Defined Error: My Scenario is: I have a Excel, in that I have first sheet "Connection" and after it I have Sheet1, Sheet2 and so on. I am combining all sheets except Sheet"Conection" by saying start with sheet2. I tried following line of code to exclude "Connection" sheet: If Not Sheet.Name = "Connection" then but it did not work. Whatever the sheets I have in some of them I have large data in some cells. Here is the code which I am using: I have highlighted the line Sub CopyFromWorksheets() Dim wrk As Workbook 'Workbook object - Always good to work with object variables Dim sht As Worksheet 'Object for handling worksheets in loop Dim trg As Worksheet 'Master Worksheet Dim rng As Range 'Range object Dim colCount As Integer 'Column count in tables in the worksheets Set wrk = ActiveWorkbook 'Working in active workbook For Each sht In wrk.Worksheets If sht.Name = "Master" Then sht.Delete Exit Sub End If Next sht 'We don't want screen updating Application.ScreenUpdating = False 'trg.SaveAs "C:\temp\CPReport1.xls" 'Add new worksheet as the last worksheet Set trg = wrk.Worksheets.Add(After:=wrk.Worksheets(wrk.Worksheets.Count)) 'Rename the new worksheet trg.Name = "Master" 'Get column headers from the first worksheet 'Column count first Set sht = wrk.Worksheets(2) colCount = sht.Cells(1, 255).End(xlToLeft).Column 'Now retrieve headers, no copy&paste needed With trg.Cells(1, 1).Resize(1, colCount) .Value = sht.Cells(1, 1).Resize(1, colCount).Value 'Set font as bold .Font.Bold = True End With trg.SaveAs "C:\temp\CPReport1.xls" 'We can start loop 'Skip Sheet - Connection If Not sht.Name = "Connection" Then For Each sht In wrk.Worksheets 'If worksheet in loop is the last one, stop execution (it is Master worksheet) If sht.Index = wrk.Worksheets.Count Then Exit For End If 'Data range in worksheet - starts from second row as first rows are the header rows in all worksheets Set rng = sht.Range(sht.Cells(2, 1), sht.Cells(65536, 1).End(xlUp).Resize(, colCount)) 'Put data into the Master worksheet '----------------- Error in below line -------------------------------------------------- trg.Cells(65536, 1).End(xlUp).Offset(1).Resize(rng.Rows.Count, rng.Columns.Count).Value = rng.Value '---------------------------------------------------------------------------------------- Next sht End If 'Fit the columns in Master worksheet trg.Columns.AutoFit 'Dim dest, destyfile 'dest = "E:\Test_Merge\" 'destyfile = dest & "_" & trg.Name 'trg.SaveAs (destyfile) 'Screen updating should be activated Application.ScreenUpdating = True End Sub

    Read the article

  • Private subnet for VM server host-only network

    - by Derek Pressnall
    At my current job, we distribute a product based on a Linux server with multiple VMs defined (using KVM / libvirt). We are planning to expose limited ports to the customer's network, and use iptables to direct inbound traffic to the appropriate internal VM. My question: is there a class of private subnets that I can use for the internal host-only network that is least likely to conflict with a client IP subnet? Specifically, if I choose a /24 out of any of the RFC-1918 defined private subnets (such as 192.168.x.x), there is a chance of conflicting with a customer-used range. I noticed that several current VM implementations default to 192.168.122.x -- is this due to an RFC that I'm not familiar with, and therefore this is a safe range to use (that most network admins would avoid)? Or did the various VM vendors just pick that range randomly? I guess I'm looking for an IP range that is more private than the existing private (RFC1918) addresses. The only other thought I had was to use one of the "Test Net" IP ranges reserved for documentation purposes (RFC 5737). Note, that I'm not worried about a customer's network blocking these IPs, as this is only internal to our server (packets get NATted before leaving the box). However this does seem more unorthodox than just sticking with the default 192.168.122.x/24 subnet.

    Read the article

  • "Randomly" occurring errors...

    - by ClarkeyBoy
    Hi, My website has a setup whereby when the application starts a module called SiteContent is "created". This runs a clearup function which basically deletes any irrelevant data from the database, in case any has been left in there from previously run functions. The module has instances of Manager classes - namely RangeManager, CollectionManager, DesignManager. There are others but I will just use these as an example. Each Manager class contains an array of items - items may be of type Range, Collection or Design, whichever one is relevant. Data for each range is then read into an instance of Range, Collection or Design. I know this is basically duplicating data - not very efficient but its my final year project at the moment so I can always change it to use Linq or something similar later, when I am not pressured by the one month deadline. I have a form which, on clicking the Save button, saves data by calling SiteContent.RangeManager.Create(vars) or SiteContent.RangeManager.Update(Range As Range, vars) (or the equivalent for other manager classes, whichever one happens to be relevant). These functions call a stored procedure to insert or update in the relevant table. Classes Range, Collection and Design all have attributes such as Name, Description, Display and several others. When the Create or Update function is called, the Manager loops through all the other items to check if an item with the same name already exists. The Update function ensures that it does not compare the item being updated to itself. A custom exception (ItemAlreadyExistsException) is thrown if another item with the same name is found. For some weird reason, if I go into a Range, Collection or Design in edit mode, change something and try to update it, it occasionally doesnt update the item. When I say occasionally I mean every 3 - 4 page loads, sometimes more. I see absolutely no pattern in when or why it occurs. I have a try-catch statement which catches ItemAlreadyExistsException, and outputs "An item with this name already exists" when caught. Occasionally it will output this; other times it will not. Does anyone have any idea why this could happen? Maybe a mistake which someone has made and solved before? I used to have regular expressions in place that the names were compared to - I believe it was [a-zA-Z]{1, 100} (between 1 and 100 lower- or upper-case characters). For some reason the customer who I am developing the site for used to get errors saying its not in the correct format. Yet he could try the same text 5 minutes later and it would work fine. I am thinking this could well be the same problem, since both problems occur at random. Many thanks in advance. Regards, Richard Clarke Edit: After much time spent narrowing down the code, I have decided to wait till my brother, who has been a programmer for at least 8 years more than I have, to come down over Easter and get him to have a look at it. If he cant solve it then I will zip the files up and put them somewhere for people to access and have a go at. I narrowed it down literally to the minimum number of files possible, and it still occurs. It seems to be about every 10th time. Having said that, I force the manager classes to refresh every 10 page loads or 5 minutes (whichever one is sooner). I may look into this - this could be causing a problem. Basically each Manager contains an array of an object. This array is populated using data from the database. The Update function takes an instance of the item and the new values to be set for the object. If it happens to be a page load where the array is reset (ie the data is loaded freshly from the database) then the object instance with the same ID wont be the same instance as the one being passed in. This explains the fact that it throws an ItemAlreadyExistsException now and then. It all makes sense now the more I think about it. If I were to pass in the ID of the object to be altered, rather than the object itself, then it should work perfectly. I will answer the question if I solve it..

    Read the article

  • Re-open Word document to previous cursor location with identical page vertical position

    - by Malcolm
    I would like to return to my previous point of edit with the page vertically positioned identical to its original vertical position. The Shift+F5 technique returns me to the previous point of edit, but the page I return to is vertically positioned on the screen in a somewhat random manner. In other words, if my cursor is 300 vertical pixels from the top of the document viewport, I would like to re-open my page so that the location of the cursor is still 300 vertical pixels from the top of my viewport. The following can be used to determine the vertical position (on the screen) of my text cursor: ActiveWindow.GetPoint pLeft, pTop, pWidth, pHeight, Selection.Range So the challenge becomes how to scroll my document in such a manner as to return my text cursor to its original vertical position (pHeight)? There is no corresponding ActiveWindow.SetPoint and ActiveWindow.ScrollIntoView scrolls a selection range into view, but offers no control over the vertical position of the selection range on the screen.

    Read the article

  • Complex error handling

    - by Caspin
    I've got a particularly ornery piece of network code. I'm using asio but that really doesn't matter for this question. I assume there is no way to unbind a socket other than closing it. The problem is that open(), bind(), and listen() can all throw a system_error. So I handled the code with a simple try/catch. The code as written in broken. using namespace boost::asio; class Thing { public: ip::tcp::endpoint m_address; ip::tcp::acceptor m_acceptor; /// connect should handle all of its exceptions internally. bool connect() { try { m_acceptor.open( m_address.protocol() ); m_acceptor.set_option( tcp::acceptor::reuse_address(true) ); m_acceptor.bind( m_address ); m_acceptor.listen(); m_acceptor.async_accept( /*stuff*/ ); } catch( const boost::system::system_error& error ) { assert(acceptor.is_open()); m_acceptor.close(); return false; } return true; } /// don't call disconnect unless connect previously succeeded. void disconnect() { // other stuff needed to disconnect is ommited m_acceptor.close(); } }; The error is if the socket fails to connect it will try to close it in the catch block and throw another system_error about closing an acceptor that has never been opened. One solution is to add an if( acceptor.is_open() ) in the catch block but that tastes wrong. Kinda like mixing C-style error checking with c++ exceptions. If I where to go that route, I may as well use the non-throwing version of open(). boost::system::error_code error; acceptor.open( address.protocol, error ); if( ! error ) { try { acceptor.set_option( tcp::acceptor::reuse_address(true) ); acceptor.bind( address ); acceptor.listen(); acceptor.async_accept( /*stuff*/ ); } catch( const boost::system::system_error& error ) { assert(acceptor.is_open()); acceptor.close(); return false; } } return !error; Is there an elegant way to handle these possible exceptions using RAII and try/catch blocks? Am I just wrong headed in trying to avoid if( error condition ) style error handling when using exceptions?

    Read the article

  • Can you reference an entire column in OpenOffice Calc (like A:A in Excel)?

    - by Andy
    I'd like to refer to an entire column, like you can in Excel by using A:A. I found a discussion on the openoffice.org forums which is a few years old, and suggests there is/was no neat way to do it. The options presented are Use A1:A65536. Use OFFSET($A$1;0;0;65536;1) as the previous range may get altered if you insert or remove rows. Use Data - Define Range... to name the column range (but which for me still just equates to $A$1:$A$1048576). These approaches seem over-complicated and still don't achieve my goal perfectly. Does anyone know of a way? Thanks, Andy

    Read the article

  • Portability of pthreads-win32 over various compilers.

    - by Artyom
    Hello, I'm using pthreads-win32 for portable threading support for windows. At least, according to the documentation pthreads-win32 should work with MSVC and even MSVC builds provided. But I don't know if the library is tested with latest MSVC compilers like MSVC-2008 and if it is supported under 64bit windows. Does anybody aware of any issues with this library? Note: Do not even try to recommend using Boost.Thread, I'm not interested in. And I'm familiar with Boost.Thread library

    Read the article

  • Cisco IOS ACL types

    - by cjavapro
    The built in command help list displays access list types based on which range. router1(config)#access-list ? <1-99> IP standard access list <100-199> IP extended access list <1100-1199> Extended 48-bit MAC address access list <1300-1999> IP standard access list (expanded range) <200-299> Protocol type-code access list <2000-2699> IP extended access list (expanded range) <700-799> 48-bit MAC address access list dynamic-extended Extend the dynamic ACL absolute timer rate-limit Simple rate-limit specific access list router1(config)# What are each of the types? Can multiple types of ACLs be applied to a given interface?

    Read the article

  • Need some help deciphering a line of assembler code, from .NET JITted code

    - by Lasse V. Karlsen
    In a C# constructor, that ends up with a call to this(...), the actual call gets translated to this: 0000003d call dword ptr ds:[199B88E8h] What is the DS register contents here? I know it's the data-segment, but is this call through a VMT-table or similar? I doubt it though, since this(...) wouldn't be a call to a virtual method, just another constructor. I ask because the value at that location seems to be bad in some way, if I hit F11, trace into (Visual Studio 2008), on that call-instruction, the program crashes with an access violation. The code is deep inside a 3rd party control library, where, though I have the source code, I don't have the assemblies compiled with enough debug information that I can trace it through C# code, only through the disassembler, and then I have to match that back to the actual code. The C# code in question is this: public AxisRangeData(AxisRange range) : this(range, range.Axis) { } Reflector shows me this IL code: .maxstack 8 L_0000: ldarg.0 L_0001: ldarg.1 L_0002: ldarg.1 L_0003: callvirt instance class DevExpress.XtraCharts.AxisBase DevExpress.XtraCharts.AxisRange::get_Axis() L_0008: call instance void DevExpress.XtraCharts.Native.AxisRangeData::.ctor(class DevExpress.XtraCharts.ChartElement, class DevExpress.XtraCharts.AxisBase) L_000d: ret It's that last call there, to the other constructor of the same class, that fails. The debugger never surfaces inside the other method, it just crashes. The disassembly for the method after JITting is this: 00000000 push ebp 00000001 mov ebp,esp 00000003 sub esp,14h 00000006 mov dword ptr [ebp-4],ecx 00000009 mov dword ptr [ebp-8],edx 0000000c cmp dword ptr ds:[18890E24h],0 00000013 je 0000001A 00000015 call 61843511 0000001a mov eax,dword ptr [ebp-4] 0000001d mov dword ptr [ebp-0Ch],eax 00000020 mov eax,dword ptr [ebp-8] 00000023 mov dword ptr [ebp-10h],eax 00000026 mov ecx,dword ptr [ebp-8] 00000029 cmp dword ptr [ecx],ecx 0000002b call dword ptr ds:[1889D0DCh] // range.Axis 00000031 mov dword ptr [ebp-14h],eax 00000034 push dword ptr [ebp-14h] 00000037 mov edx,dword ptr [ebp-10h] 0000003a mov ecx,dword ptr [ebp-0Ch] 0000003d call dword ptr ds:[199B88E8h] // this(range, range.Axis)? 00000043 nop 00000044 mov esp,ebp 00000046 pop ebp 00000047 ret Basically what I'm asking is this: What the purpose of the ds:[ADDR] indirection here? VMT-table is only for virtual isn't it? and this is constructor Could the constructor have yet to be JITted, which could mean that the call would actually call through a JIT shim? I'm afraid I'm in deep water here, so anything might and could help. Edit: Well, the problem just got worse, or better, or whatever. We are developing the .NET feature in a C# project in a Visual Studio 2008 solution, and debugging and developing through Visual Studio. However, in the end, this code will be loaded into a .NET runtime hosted by a Win32 Delphi application. In order to facilitate easy experimentation of such features, we can also configure the Visual Studio project/solution/debugger to copy the produced dll's to the Delphi app's directory, and then execute the Delphi app, through the Visual Studio debugger. Turns out, the problem goes away if I run the program outside of the debugger, but during debugging, it crops up, every time. Not sure that helps, but since the code isn't slated for production release for another 6 months or so, then it takes some of the pressure off of it for the test release that we have soon. I'll dive into the memory parts later, but probably not until over the weekend, and post a followup.

    Read the article

  • Using WDS to make a router act like a makeshift signal booster

    - by cornjuliox
    I've got a router that supports WDS, and I was wondering if I could use it to help extend the range of an existing wireless router? The PC I'm using right now is just barely within the signal range of a wireless router, and the signal is rather weak so I moved my wireless USB adapter away from the computer using a USB extension cord and used a pie tin + some packing tape + a stack of books and a tall wooden stand to make a sort of reflector dish. Sometime in the future I'd like other PCs to be able to connect wirelessly but with the way things are set up I can't move any farther from this spot or I lose the signal entirely. Can I use WDS to bridge the two networks together both to increase the range of the first network and allow computers connected to the 2nd router to share internet access?

    Read the article

  • Is there a way to determine which service does an outgoing connection?

    - by fluxtendu
    I'm redoing my firewall configuration with more restrictive policies and I would like to determine the provenance (and/or destination) of some outgoing connections. I have an issue because they come from svchost.exe and go to web content/application delivery providers - or similar: 5 IP in range: 82.96.58.0 - 82.96.58.255 --> Akamai Technologies akamaitechnologies.com 3 IP in range: 93.150.110.0 - 93.158.111.255 --> Akamai Technologies akamaitechnologies.com 2 IP in range: 87.248.194.0 - 87.248.223.255 --> LLNW Europe 2 llnw.net 205.234.175.175 --> CacheNetworks, Inc. cachefly.net 188.121.36.239 --> Go Daddy Netherlands B.V. secureserver.net So is it possible to know which service does a particular connection? Or what's your recommendation about the rules applied to these ones? (Comodo Firewall & Windows 7)