Missing whole disk device in OpenSolaris
Posted
by Jeff Mc
on Server Fault
See other posts from Server Fault
or by Jeff Mc
Published on 2010-04-19T15:02:44Z
Indexed on
2010/04/19
15:13 UTC
Read the original article
Hit count: 287
I have begun experimenting with Solaris and ZFS as a NAS. All was going very smoothly until I had a drive failure. When I replaced the drive, I no longer have a device file mapped to the whole disk. /dev/dsk/c7t3d0
does not exist but c7t2d0
and c7t4d0
both do. Also the sd@3,0:wd
file under the /devices/
tree is non-existent. Do I have to prepare/partition the disk somehow to cause the whole disk device to exist?
Here are a few outputs that might be useful.
jeffmc@ats-ds2:/dev/dsk$ zpool status pool: datapool state: DEGRADED status: One or more devices could not be opened. Sufficient replicas exist for the pool to continue functioning in a degraded state. action: Attach the missing device and online it using 'zpool online'. see: http://www.sun.com/msg/ZFS-8000-2Q scrub: none requested config: NAME STATE READ WRITE CKSUM datapool DEGRADED 0 0 0 mirror-0 DEGRADED 0 0 0 c7t2d0 ONLINE 0 0 0 c7t3d0 UNAVAIL 0 0 0 cannot open mirror-1 ONLINE 0 0 0 c7t4d0 ONLINE 0 0 0 c7t5d0 ONLINE 0 0 0
jeffmc@ats-ds2:/dev/dsk$ zpool replace datapool c7t3d0 cannot open 'c7t3d0': no such device in /dev/dsk must be a full path or shorthand device name
jeffmc@ats-ds2:/dev/dsk$ sudo format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c7t0d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@0,0 1. c7t1d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@1,0 2. c7t2d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@2,0 3. c7t3d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@3,0 4. c7t4d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@4,0 5. c7t5d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@5,0