Assembly Load and loading the "sub-modules" dependencies - "cannot fild the file specified"
Posted
by Ted
on Stack Overflow
See other posts from Stack Overflow
or by Ted
Published on 2010-05-25T15:26:42Z
Indexed on
2010/05/25
15:51 UTC
Read the original article
Hit count: 255
There are several questions out there that ask the same question. However the answers they received I cannot understand, so here goes:
Similar questions:
http://stackoverflow.com/questions/1874277/dynamically-load-assembly-and-manually-force-path-to-get-referenced-assemblies ;
http://stackoverflow.com/questions/22012/loading-assemblies-and-its-dependencies-closed
The question in short: I need to figure out how dependencies, ie References in my modules can be loaded dynamically. Right now I am getting "The system cannot find the file specified" on Assemblies referenced in my so called modules.
I cannot really get how to use the AssemblyResolve event...
The longer version
I have one application, MODULECONTROLLER, that loads separate modules.
These "separate modules" are located in well-known subdirectories, like
appBinDir\Modules\Module1
appBinDir\Modules\Module2
Each directory contains all the DLLs that exists in the bin-directory of those projects after a build.
So the MODULECONTROLLER loads all the DLLs contained in those folders using this code:
byte[] bytes = File.ReadAllBytes(dllFileFullPath);
Assembly assembly = null;
assembly = Assembly.Load(bytes);
I am, as you can see, loading the byte[]-array (so I dont lock the DLL-files).
Now, in for example MODULE1, I have a static reference called MyGreatXmlProtocol. The MyGreatXmlProtocol.dll then also exists in the directory appBinDir\Modules\Module1
and is loaded using the above code
When code in the MODULE1 tries to use this MyGreatXmlProtocol, I get:
Could not load file or assembly 'MyGreatXmlProtocol, Version=1.0.3797.26527, Culture=neutral, PublicKeyToken=null' or one of its dependencies. The system cannot find the file specified.
So, in a post (like this one) they say that
To my understanding reflection will load the main assembly and then search the GAC for the referenced assemblies, if it cannot find it there, you can then incorparate an assemblyResolve event:
First; is it really needed to use the AssemblyResolve-event to make this work? Shouldnt my different MODULEs themself load their DLLs, as they are statically referenced?
Second; if AssemblyResolve is the way to go - how do I use it? I have attached a handler to the Event but I never get anything on MyGreatXmlProctol...
=== EDIT === CODE regarding the AssemblyResolve-event handler:
public GUI()
{
InitializeComponent();
AppDomain.CurrentDomain.AssemblyResolve += new ResolveEventHandler(CurrentDomain_AssemblyResolve);
...
}
//
Assembly CurrentDomain_AssemblyResolve(object sender, ResolveEventArgs args)
{
Console.WriteLine(args.Name);
return null;
}
Hope I wasnt too fuzzy =)
Thx
© Stack Overflow or respective owner