We really welcome every external review of our slides. And also recommendations from customers visiting our workshops. So it happened to me more than a week ago that Marco Patzwahl, the owner of MuniqSoft GmbH, had a very lengthy train ride in Germany (as the engine drivers go on strike this week it could have become even worse) and nothing better to do then reviewing our slide set. And he had plenty of recommendations.
Besides that he pointed us to something at least I was not aware of and added it to the slides:
In patch set 11.2.0.2 a new behaviour for datafile write errors has been implemented. With this release ANY write error to a datafile will cause the instance to abort. Before 11.2.0.2 those errors usually led to an offline datafile if the database operates in archivelog mode (your production database do, don’t they?!) and the datafile does not belong to the SYSTEM tablespace. Internal discussion found this behaviour not up-to-date and alligned with RAC systems and modern storages. Therefore it has been changed and a new underscore parameter got introduced.
_DATAFILE_WRITE_ERRORS_CRASH_INSTANCE=TRUE
This is the default setting´and the new behaviour beginning with Oracle 11.2.0.2
If you would like to revert to the pre-11.2.0.2 behaviour you’ll have to set in your init.ora/spfile this parameter to false. But keep in mind that there’s a reason why this has been changed.
You’ll find more info in MOS Note: 7691270.8 and this topic in the current version of the slides on slide 255.
Thanks to Marco for the review!!
And then I received an email from Kurt Van Meerbeeck today. Kurt is pretty well known in the Oracle community. And he’s the owner of jDUL/DUDE, a database unloading tool which bypasses the Oracle database engine and access data direclty from the blocks.
Kurt visited the upgrade workshop two weeks ago in Belgium and did highlight to me that since Oracle 11.2.0.1 even though you haven’t set neither SGA_TARGET nor MEMORY_TARGET the database might still do resize operations. Reason why this behaviour has been changed: Prevention of ORA-4031 errors. But on databases with extremly high loads this can cause trouble. Further information can be found in MOS Note:1269139.1 . And the parameter set to TRUE by default is called
_MEMORY_IMM_MODE_WITHOUT_AUTOSGA=TRUE
This can be found now in the slide set as well on slide number 240. And thanks to Kurt for this information!!