Search Results

Search found 5 results on 1 pages for 'apd'.

Page 1/1 | 1 

  • Issue with VMWare vSphere and NFS: re occurring apd state

    - by Bastian N.
    I am experiencing issues with VMWare vSphere 5.1 and NFS storage on 2 different setups, which result in an "All Path Down" state for the NFS shares. This first happened once or twice a day, but lately it occurs much more frequent, as specially when Acronis Backup jobs are running. Setup 1 (Production): 2 ESXi 5.1 hosts (Essentials Plus) + OpenFiler with NFS as storage Setup 2 (Lab): 1 ESXi 5.1 host + Ubuntu 12.04 LTS with NFS as storage Here is an example from the vmkernel.log: 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 248: APD Timer started for ident [987c2dd0-02658e1e] 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 395: Device or filesystem with identifier [987c2dd0-02658e1e] has entered the All Paths Down state. 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 846: APD Start for ident [987c2dd0-02658e1e]! 2013-05-28T08:07:37.485Z cpu0:2052)NFSLock: 610: Stop accessing fd 0x410007e4cf28 3 2013-05-28T08:07:37.485Z cpu0:2052)NFSLock: 610: Stop accessing fd 0x410007e4d0e8 3 2013-05-28T08:07:41.280Z cpu1:2049)StorageApdHandler: 277: APD Timer killed for ident [987c2dd0-02658e1e] 2013-05-28T08:07:41.280Z cpu1:2049)StorageApdHandler: 402: Device or filesystem with identifier [987c2dd0-02658e1e] has exited the All Paths Down state. 2013-05-28T08:07:41.281Z cpu1:2049)StorageApdHandler: 902: APD Exit for ident [987c2dd0-02658e1e]! 2013-05-28T08:07:52.300Z cpu1:3679)NFSLock: 570: Start accessing fd 0x410007e4d0e8 again 2013-05-28T08:07:52.300Z cpu1:3679)NFSLock: 570: Start accessing fd 0x410007e4cf28 again As long as the issue occurred once or twice a day it really wasn't a problem, but now this issue has impact on the VMs. The VMs get slow or even hang, resulting in a reset through vCenter in the production environment. I searched the web extensively and asked in forums, but till now nobody was able to help me. Based on blog posts and VMWare KB articles I tried the following NFS settings: Net.TcpipHeapSize = 32 Net.TcpipHeapMax = 128 NFS.HartbeatFrequency = 12 NFS.HartbeatMaxFailures = 10 NFS.HartbeatTimeout = 5 NFS.MaxQueueDepth = 64 Instead of NFS.MaxQueueDepth = 64 I already tried other settings like NFS.MaxQueueDepth = 32 or even NFS.MaxQueueDepth = 1. Unfortunately without any luck. It would be great if someone could help me on this issue. It is really annoying. Thanks in advance for all the help. [UPDATE] As I explained in the comment below, here is the network setup: On the production setup the NFS traffic is bound to a separate VLAN with ID 20. I am using a HP 1810 24 Port Switch. The OpenFiler system is connected to the VLAN with 4 Intel GbE NICs with dynamic LACP. The ESXis both have 4 Intel GbE NICs using 2 static LACP trunks containing 2 NICs each. One pair is connected to the regular LAN and the other one to the VLAN 20. And here is a screenshot of the vSwitch: Switch configuration: Port configuration: On the lab setup its a single Intel NIC on each side without VLAN, but with different IP subnet.

    Read the article

  • Renaming Functions during runtime in PHP.

    - by The Rook
    In PHP 5.3 is there a way to rename a function or "hook" a function. There is the rename_function() within "APD" which has been broken since ~2004. If you try and build it on PHP 5.3 you'll get this error: 'struct _zend_compiler_globals' has no member named 'extended_info' This is a really easy error to fix, just change this line: GC(extended_info) = 1; to CG(compiler_options) |= ZEND_COMPILE_EXTENDED_INFO; I modified my php.ini and the APD shows up in my phpinfo() as it should. However when i call rename_function() the PHP page doesn't load and I get a segmentation fault in my /var/log/apache2/error.log. Is there anyway to fix APD to work with a modern version of PHP? Or is there another method to rename functions? Why on earth is vital feature not in php!??!?! (Gotta love python :)

    Read the article

  • vSphere ESX 5.5 hosts cannot connect to NFS Server

    - by Gerald
    Summary: My problem is I cannot use the QNAP NFS Server as an NFS datastore from my ESX hosts despite the hosts being able to ping it. I'm utilising a vDS with LACP uplinks for all my network traffic (including NFS) and a subnet for each vmkernel adapter. Setup: I'm evaluating vSphere and I've got two vSphere ESX 5.5 hosts (node1 and node2) and each one has 4x NICs. I've teamed them all up using LACP/802.3ad with my switch and then created a distributed switch between the two hosts with each host's LAG as the uplink. All my networking is going through the distributed switch, ideally, I want to take advantage of DRS and the redundancy. I have a domain controller VM ("Central") and vCenter VM ("vCenter") running on node1 (using node1's local datastore) with both hosts attached to the vCenter instance. Both hosts are in a vCenter datacenter and a cluster with HA and DRS currently disabled. I have a QNAP TS-669 Pro (Version 4.0.3) (TS-x69 series is on VMware Storage HCL) which I want to use as the NFS server for my NFS datastore, it has 2x NICs teamed together using 802.3ad with my switch. vmkernel.log: The error from the host's vmkernel.log is not very useful: NFS: 157: Command: (mount) Server: (10.1.2.100) IP: (10.1.2.100) Path: (/VM) Label (datastoreNAS) Options: (None) cpu9:67402)StorageApdHandler: 698: APD Handle 509bc29f-13556457 Created with lock[StorageApd0x411121] cpu10:67402)StorageApdHandler: 745: Freeing APD Handle [509bc29f-13556457] cpu10:67402)StorageApdHandler: 808: APD Handle freed! cpu10:67402)NFS: 168: NFS mount 10.1.2.100:/VM failed: Unable to connect to NFS server. Network Setup: Here is my distributed switch setup (JPG). Here are my networks. 10.1.1.0/24 VM Management (VLAN 11) 10.1.2.0/24 Storage Network (NFS, VLAN 12) 10.1.3.0/24 VM vMotion (VLAN 13) 10.1.4.0/24 VM Fault Tolerance (VLAN 14) 10.2.0.0/24 VM's Network (VLAN 20) vSphere addresses 10.1.1.1 node1 Management 10.1.1.2 node2 Management 10.1.2.1 node1 vmkernel (For NFS) 10.1.2.2 node2 vmkernel (For NFS) etc. Other addresses 10.1.2.100 QNAP TS-669 (NFS Server) 10.2.0.1 Domain Controller (VM on node1) 10.2.0.2 vCenter (VM on node1) I'm using a Cisco SRW2024P Layer-2 switch (Jumboframes enabled) with the following setup: LACP LAG1 for node1 (Ports 1 through 4) setup as VLAN trunk for VLANs 11-14,20 LACP LAG2 for my router (Ports 5 through 8) setup as VLAN trunk for VLANs 11-14,20 LACP LAG3 for node2 (Ports 9 through 12) setup as VLAN trunk for VLANs 11-14,20 LACP LAG4 for the QNAP (Ports 23 and 24) setup to accept untagged traffic into VLAN 12 Each subnet is routable to another, although, connections to the NFS server from vmk1 shouldn't need it. All other traffic (vSphere Web Client, RDP etc.) goes through this setup fine. I tested the QNAP NFS server beforehand using ESX host VMs atop of a VMware Workstation setup with a dedicated physical NIC and it had no problems. The ACL on the NFS Server share is permissive and allows all subnet ranges full access to the share. I can ping the QNAP from node1 vmk1, the adapter that should be used to NFS: ~ # vmkping -I vmk1 10.1.2.100 PING 10.1.2.100 (10.1.2.100): 56 data bytes 64 bytes from 10.1.2.100: icmp_seq=0 ttl=64 time=0.371 ms 64 bytes from 10.1.2.100: icmp_seq=1 ttl=64 time=0.161 ms 64 bytes from 10.1.2.100: icmp_seq=2 ttl=64 time=0.241 ms Netcat does not throw an error: ~ # nc -z 10.1.2.100 2049 Connection to 10.1.2.100 2049 port [tcp/nfs] succeeded! The routing table of node1: ~ # esxcfg-route -l VMkernel Routes: Network Netmask Gateway Interface 10.1.1.0 255.255.255.0 Local Subnet vmk0 10.1.2.0 255.255.255.0 Local Subnet vmk1 10.1.3.0 255.255.255.0 Local Subnet vmk2 10.1.4.0 255.255.255.0 Local Subnet vmk3 default 0.0.0.0 10.1.1.254 vmk0 VM Kernel NIC info ~ # esxcfg-vmknic -l Interface Port Group/DVPort IP Family IP Address Netmask Broadcast MAC Address MTU TSO MSS Enabled Type vmk0 133 IPv4 10.1.1.1 255.255.255.0 10.1.1.255 00:50:56:66:8e:5f 1500 65535 true STATIC vmk0 133 IPv6 fe80::250:56ff:fe66:8e5f 64 00:50:56:66:8e:5f 1500 65535 true STATIC, PREFERRED vmk1 164 IPv4 10.1.2.1 255.255.255.0 10.1.2.255 00:50:56:68:f5:1f 1500 65535 true STATIC vmk1 164 IPv6 fe80::250:56ff:fe68:f51f 64 00:50:56:68:f5:1f 1500 65535 true STATIC, PREFERRED vmk2 196 IPv4 10.1.3.1 255.255.255.0 10.1.3.255 00:50:56:66:18:95 1500 65535 true STATIC vmk2 196 IPv6 fe80::250:56ff:fe66:1895 64 00:50:56:66:18:95 1500 65535 true STATIC, PREFERRED vmk3 228 IPv4 10.1.4.1 255.255.255.0 10.1.4.255 00:50:56:72:e6:ca 1500 65535 true STATIC vmk3 228 IPv6 fe80::250:56ff:fe72:e6ca 64 00:50:56:72:e6:ca 1500 65535 true STATIC, PREFERRED Things I've tried/checked: I'm not using DNS names to connect to the NFS server. Checked MTU. Set to 9000 for vmk1, dvSwitch and Cisco switch and QNAP. Moved QNAP onto VLAN 11 (VM Management, vmk0) and gave it an appropriate address, still had same issue. Changed back afterwards of course. Tried initiating the connection of NAS datastore from vSphere Client (Connected to vCenter or directly to host), vSphere Web Client and the host's ESX Shell. All resulted in the same problem. Tried a path name of "VM", "/VM" and "/share/VM" despite not even having a connection to server. I plugged in a linux system (10.1.2.123) into a switch port configured for VLAN 12 and tried mounting the NFS share 10.1.2.100:/VM, it worked successfully and I had read-write access to it I tried disabling the firewall on the ESX host esxcli network firewall set --enabled false I'm out of ideas on what to try next. The things I'm doing differently from my VMware Workstation setup is the use of LACP with a physical switch and a virtual distributed switch between the two hosts. I'm guessing the vDS is probably the source of my troubles but I don't know how to fix this problem without eliminating it.

    Read the article

  • Cientos de Directores Financieros se congregaron en el evento “Innovación y Excelencia en la Función Financiera”

    - by Noelia Gomez
    v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} w\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} El pasado 24 de Octubre tuvo lugar el evento “Innovación y Excelencia en la Función Financiera” en la Fundación Rafael de Pino, Madrid (que ya anunciamos aquí). APD, en colaboración con Oracle, organizaron esta jornada con el objetivo de analizar el proceso de transformación del Director Financiero en las compañías (aquí puedes ver un estudio sobre ello). Enrique Sanchez de Leon, Director de APD, fue el encargado de abrir la jornada con una calurosa bienvenida a los invitados. Tras él, Fernando Rumbero, Iberia Applications Cluster Leader de Oracle , comenzó dando unas pinceladas sobre los cambios a los que los Directores Financieros deben estar preparados para convertirse en parte de la estrategia de la compañía. Después de que todos los ponentes fueran presentados y se acomodaran en su lugar del escenario de aquella gran sala, Oriol Farré, Presales Director de Oracle, tomó la palabra para profundizar sobre el nuevo rol estratégico del Director Financiero y cómo éste se está convirtiendo cada vez más en el catalizador del cambio dentro de las empresas (¿tú lo eres? aquí hablamos de cómo puedes evaluarlo) Por su parte, Maria Jesús Carrato, Profesora de Dirección Financiera Internacional en el IE y Directora Financiera del Grupo SM mostró su visión sobre cómo serán los Departamentos Financieros del futuro. Después llego el turno de Ramón Arguelaguet, Financial Controller & Reporting Senior Manager de Vodafone, que profundizo en la innovación y la transformación lideradas por los Directores Financieros dentro de las organizaciones. Por último, pero no menos importante, Juan Jesús Donoso, Director Económico de Cruz Roja Española, nos mostro el punto de vista de la gestión de una organización sin ánimo de lucro. Finalmente, en la mesa redonda, cada uno de los integrantes dio su punto de vista sobre el nuevo rol de Director Financiero y los nuevos retos a los que se enfrentan. El broche final de la jornada la puso el coctel para abrir paso a un espacio de networking que sin duda los cientos de Directores Financieros aprovecharon para intercambiar puntos de vista, conocer a nuevos compañeros y reencontrarse con muchos otros. Si estuviste en el evento… ¿qué te pareció? Tal vez no encontraste el momento de plantear alguna cuestión. Ahora puedes hacerlo en los comentarios y se lo trasladaremos a los ponentes. Contact 12.00 Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Calibri","sans-serif";}

    Read the article

1