  • How do I resolve an "Invalid Transaction" error saving a zone config in Brocade Web Tools?

    - by Frank Szczerba
    When trying to save zoning changes in the Zone Administration tool in Brocade Web Tools, I get the status "Failed to commit changes to fabric" and the messages window shows: --- start of commit (Enable Config) at: Fri Jul 23 2010 19:43:40 GMT+00:00 Invalid Transaction --- end of commit at: Fri Jul 23 2010 19:43:47 GMT+00:00 I've tried refreshing the config and just re-saving what is already on the switch, but can't get this message to go away.

    Read the article

  • Brocade 200E Switch - Fibre Channel

    - by Arthor
    What I have: Fujitsu-Siemens PRIMERGY BX600 Brocade 200E (16 port, 4gbit fibre). My question: Imagine a QNAP with a fiber 10GBIT card connected to the Brocade 200E (16 port, 4gbit fibre). Would this work; would the card drop down to 4GBIT? Are 10GBIT fiber cards backwards completable. Update. I have the specs of my server now.... Fujitsu-Siemens PRIMERGY BX600 S3 Blade Ecosystem Blade Chassis comprising; 2 x A3C40073243 Blade Management modules 2 x A3C40089238 GBE Switch Blade SB9F 30/12 2 x A3C40085736 4Gb 10 port pass through blades 1 x A3C40083767 Digital KVM Modules 2 x A3C40073245 Fan enclosures + cooling fans 4 x A3C40073262 Power Supplies My Goals and Objectives To have a blade system in place for 8 blades for video rendering, the other 2 for database and scripts etc The system will be built on VMWARE ESXi 5 Use ISCSI on the QNAP to support HA and vmotion if needed Users to access the qnap for video editing QANAP has 12 drive (2 x (6 HDD in RAID 10)

    Read the article

  • alias name in brocade

    - by wildchild
    how do i look for alias name using the WWN in brocade. Say i have created an alias "CentosNode2Port1" using switch show i get the WWN ,but how to look for the alias name. alishow (WWN) is not accepting. please help

    Read the article

  • How to set Brocade 200E SAN Fabric Switch Port Health Monitoring to "monitored"

    - by Kenny
    Hi, I have a Brocade SAN Fabric Switch, a 200E. When using the web based management interface "SwitchExplorer" I can click the port, and I see "Port Administration Services". In the first screen of data that appreas, there's a row called "Health" which has value "Unmonitored". Do you know how to set this port to be Monitored? And if also - what "Health" monitoring does? I'm hoping it'll email or log if there's a connection or disconnection.. Many thanks for looking... Kenny

    Read the article

  • How does Brocade (Foundry) FastIron CX compare to Cisco 3750 stackable switches?

    - by Paul
    We're considering Brocade's CX series vs. Cisco's 3750 at both core and distribution layers for a new site with gig to desktop, without POE. If you have any hands-on experience with FastIron CX switches, I would greatly value your impressions. I'll gladly add mine to the discussion when we get some quality time with our eval units (one just arrived yesterday, another's on the way). Thank you!

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

  • Kernel Error during upgrade or update commands

    - by Ashesh
    I am getting these errors during sudo apt-get update and upgrade... I tried all possible options no success. I recently upgraded to 13.04 and had problems with Broadcom WiFi. Fixed tat issues using the clean script... but looks like it did not install the Kernel properly.. Here is the o/p of the few scripts I ran: ashesh@ashesh-HPdv4:~$ sudo dpkg -r bcmwl-kernel-source (Reading database ... 175338 files and directories currently installed.) Removing bcmwl-kernel-source ... Removing all DKMS Modules Done. update-initramfs: deferring update (trigger activated) Processing triggers for initramfs-tools ... update-initramfs: Generating /boot/initrd.img-3.8.0-25-generic cp: reading ‘/lib/modules/3.8.0-25-generic/kernel/drivers/mtd/mtd.ko’: Input/output error cp: failed to extend ‘/tmp/mkinitramfs_8gjKwQ//lib/modules/3.8.0-25-generic/kernel/drivers/mtd/mtd.ko’: Input/output error cp: reading ‘/lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/sfc/sfc.ko’: Input/output error cp: failed to extend ‘/tmp/mkinitramfs_8gjKwQ//lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/sfc/sfc.ko’: Input/output error cp: reading ‘/lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko’: Input/output error cp: failed to extend ‘/tmp/mkinitramfs_8gjKwQ//lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko’: Input/output error cp: reading ‘/lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/broadcom/bnx2x/bnx2x.ko’: Input/output error cp: failed to extend ‘/tmp/mkinitramfs_8gjKwQ//lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/broadcom/bnx2x/bnx2x.ko’: Input/output error cp: reading ‘/lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/broadcom/cnic.ko’: Input/output error cp: failed to extend ‘/tmp/mkinitramfs_8gjKwQ//lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/broadcom/cnic.ko’: Input/output error cp: reading ‘/lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/qlogic/netxen/netxen_nic.ko’: Input/output error cp: failed to extend ‘/tmp/mkinitramfs_8gjKwQ//lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/qlogic/netxen/netxen_nic.ko’: Input/output error cp: reading ‘/lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/brocade/bna/bna.ko’: Input/output error cp: failed to extend ‘/tmp/mkinitramfs_8gjKwQ//lib/modules/3.8.0-25-generic/kernel/drivers/net/ethernet/brocade/bna/bna.ko’: Input/output error cp: reading ‘/lib/modules/3.8.0-25-generic/kernel/drivers/scsi/libfc/libfc.ko’: Input/output error cp: failed to extend ‘/tmp/mkinitramfs_8gjKwQ//lib/modules/3.8.0-25-generic/kernel/drivers/scsi/libfc/libfc.ko’: Input/output error cp: reading ‘/lib/modules/3.8.0-25-generic/kernel/drivers/scsi/advansys.ko’: Input/output error cp: failed to extend ‘/tmp/mkinitramfs_8gjKwQ//lib/modules/3.8.0-25-generic/kernel/drivers/scsi/advansys.ko’: Input/output error cp: reading ‘/lib/modules/3.8.0-25-generic/kernel/drivers/scsi/be2iscsi/be2iscsi.ko’: Input/output error cp: failed to extend ‘/tmp/mkinitramfs_8gjKwQ//lib/modules/3.8.0-25-generic/kernel/drivers/scsi/be2iscsi/be2iscsi.ko’: Input/output error cp: reading ‘/lib/modules/3.8.0-25-generic/kernel/drivers/scsi/bnx2i/bnx2i.ko’: Input/output error cp: failed to extend ‘/tmp/mkinitramfs_8gjKwQ//lib/modules/3.8.0-25-generic/kernel/drivers/scsi/bnx2i/bnx2i.ko’: Input/output error Bus error (core dumped) depmod: ../libkmod/libkmod-elf.c:207: elf_get_mem: Assertion `offset < elf->size' failed. Aborted (core dumped) I am not a techie but I need your support to resolve this without re-installation from scratch....

    Read the article

  • alias name in bracade

    - by wildchild
    how do i look for alias name using the WWN in brocade. Say i have created an alias "CentosNode2Port1" using switch show i get the WWN ,but how to look for the alias name. alishow (WWN) is not accepting. please help

    Read the article

  • Multiple VLANs on a single subnet

    - by mstaessen
    I would like to establish the setup shown below. The image is taken from (http://gcharriere.com/blog/?p=620) and explains how to set this up on a brocade device. I would like to use an ubuntu server to do the routing. Right now, the switch and the server/router are connected with a trunk and the server uses the vlan package, kernel module and (inner) subnets for routing. I would like that: no IP addresses get lost in the subnetting (outer subnet is /26, inner subnets are /28) I don't want the rigorous subdivision of my outer subnet. I want to assign a VLAN to any IP in the outer subnet. How do I need to configure my interfaces? What is the "ubuntu" translation of "ip follow ve"? Thanks!

    Read the article

  • The Oracle Enterprise Linux Software and Hardware Ecosystem

    - by sergio.leunissen
    It's been nearly four years since we launched the Unbreakable Linux support program and with it the free Oracle Enterprise Linux software. Since then, we've built up an extensive ecosystem of hardware and software partners. Oracle works directly with these vendors to ensure joint customers can run Oracle Enterprise Linux. As Oracle Enterprise Linux is fully--both source and binary--compatible with Red Hat Enterprise Linux (RHEL), there is minimal work involved for software and hardware vendors to test their products with it. We develop our software on Oracle Enterprise Linux and perform full certification testing on Oracle Enterprise Linux as well. Due to the compatibility between Oracle Enterprise Linux and RHEL, Oracle also certifies its software for use on RHEL, without any additional testing. Oracle Enterprise Linux tracks RHEL by publishing freely downloadable installation media on edelivery.oracle.com/linux and updates, bug fixes and security errata on Unbreakable Linux Network (ULN). At the same time, Oracle's Linux kernel team is shaping the future of enterprise Linux distributions by developing technologies and features that matter to customers who deploy Linux in the data center, including file systems, memory management, high performance computing, data integrity and virtualization. All this work is contributed to the Linux and Xen communities. The list below is a sample of the partners who have certified their products with Oracle Enterprise Linux. If you're interested in certifying your software or hardware with Oracle Enterprise Linux, please contact us via [email protected] Chip Manufacturers Intel, Intel Enabled Server Acceleration Alliance AMD Server vendors Cisco Unified Computing System Dawning Dell Egenera Fujitsu HP Huawei IBM NEC Sun/Oracle Storage Systems, Volume Management and File Systems 3Par Compellent EMC VPLEX FalconStor Fusion-io Hitachi Data Systems HP Storage Array Systems Lustre Network Appliance OCFS2 PillarData Symantec Veritas Storage Foundation Networking: Switches, Host Bus Adapters (HBAs), Converged Network Adapters (CNAs), InfiniBand Brocade Emulex Mellanox QLogic Voltaire SOA and Middleware ActiveState ActivePerl, ActivePython Tibco Zend Backup, Recovery & Replication Arkeia Network Backup Suite BakBone NetVault CommVault Simpana 8 EMC Networker, Replication Manager FalconStor Continuous Data Protector HP Data Protector NetApp Snapmanager Quest LiteSpeed Engine Steeleye Data Replication, Disaster Recovery Symantec NetBackup, Veritas Volume Replicator, Symantec Backup Exec Zmanda Amanda Enterprise Data Center Automation BMC CA Unicenter HP Server Automation (formerly Opsware), System Management Homepage Oracle Enterprise Manager Ops Center Quest Vizioncore vFoglight Pro TeamQuest Manager Clustering & High Availability FUJITSU x10sure NEC Express Cluster X Steeleye Lifekeeper Symantec Cluster Server Univa UniCluster Virtualization Platforms and Cloud Providers Amazon EC2 Citrix XenServer Rackspace Cloud VirtualBox VMWare ESX Security Management ArcSight: Enterprise Security Manager, Logger CA Access Control Centrify Suite Ecora Auditor FoxT Manager Likewise: Unix Account Management Lumension Endpoint Management and Security Suite QualysGuard Suite Quest Privilege Manager McAfee Application Control, Change ControlIntegrity Monitor, Integrity Control, PCI Pro Solidcore S3 Symantec Enterprise Security Manager (ESM) Tripwire Trusted Computer Solutions

    Read the article

  • It's All In The Cloud

    - by Natalia Rachelson
    People turned out in droves for Steve Miranda's Apps Cloud General Session. Steve, as engaging as ever, covered our Apps strategy in the cloud and reinforced that Oracle has a complete set of cloud services including: •    Human Capital Management•    Talent Management•    Sales and Marketing•    Customer Service and Support•    Financial Management•    Procurement, Sourcing, and Inventory•    Project Portfolio Management•    Governance, Risk, and Compliance... all delivered on top of the Social, Platform, and Common Infrastructure.Steve talked about Fusion being the centerpiece of our Cloud Services. The fact that Fusion is 100 percent standards based is a big, big deal! In addition, our ERP Cloud Service is the most complete cloud service on the market. And email marketing is dead -- social marketing is where the action is. It's also where Oracle is investing heavily from a Sales & Marketing Cloud perspective. Steve covered the strategic acquisitions Oracle has made to enhance our organic Cloud offering. Specifically, Oracle bought RightNow to make our Customer Service and Support Cloud service complete. We also bought Taleo to add Recruiting and Learning capabilities to our Talent Management Cloud. Steve talked about our customers and how they are benefiting from the use of a variety of our Cloud Services. Red Robin is driving lower labor and food costs with Oracle ERP Cloud Service. He used Elizabeth Arden as the profile customer for HCM and Talent Management Service, UBS for HCM and Talent Management Service, and Brocade for Talent Management. All these customers are benefiting from a comprehensive and fully integrated HR platform that aligns compensation with performance and enhances workforce motivation and retention. At the same time, Hitachi Data Systems is using Oracle Taleo Performance Management Cloud to recruit the right competencies, pinpoint areas of improvement, and develop and monitor employee goals to support the global account organization. KLM and Overstock.com are gaining the benefits of Oracle's Customer Service and Support Service from RightNow by better engaging and serving customer needs online and through call centers. And last but not least, Graco and Key Energy are leveraging mobility features and sales forecasting and territory management capabilities within the Oracle Sales and Marketing Service. They expect to gain better visibility to sales information and drive more efficient sales campaigns and empower their sales force with data they need to make sales. Overall, Oracle Apps Cloud Services are enjoying a significant momentum in the marketplace. Steve projected an air of confidence and enthusiasm highlighting Oracle's latest successes with Cloud services.

    Read the article

  • MultiPath configuration on RHEL5 and Clariion CX-300

    - by Kamil Z
    I have problem with discovering my FC-connected CX-300 storage. Frankly speaking I'm complete novice in FibreChannel, so step by step explanation would be appreciated. My configuration consist of two IBM HS20 blades with RHEL5.4 on board and 2x Qlogic ISP2422-based 4Gb Fibre Channel HBAs on each blade. As a FC switch there are two Brocades built in BladeCenter Chassis, and finally there is EMC Clariion CX-300. CX300, and Brocade switches should be configured properly, because they were working fine with previous configuration, which main defference was RHEL3 instead RHEL5.4 Below there is my output from several usefull commands: #lspci | grep Fibre 06:01.0 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) 06:01.1 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) #lsmod | grep qla qla2xxx 1084741 0 scsi_transport_fc 37577 1 qla2xxx scsi_mod 141717 10 scsi_dh,qla2xxx,sg,scsi_transport_fc,usb_storage,libata,mptspi,mptscsih,scsi_transport_spi,sd_mod #cat /proc/scsi/scsi Attached Devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: LSILOGIC Model: 1030 IM IM Rev: 1000 Type: Direct-Access ANSI SCSI revision: 02 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 I'd followed instructions from this site (editing /etc/multipath.conf), but i failed after multipath -ll - the output was empty. Do you have any suggestions about discovering FC Connected LUNs in such configuration?

    Read the article

  • NetBackup prefers "Scratch" tapes over dedicated tapes

    - by wfaulk
    I have a NetBackup 6.0MP7 installation running on Windows Server 2003. It functions as the only Master Server and Media Server. I swap a full set of tapes in and out every week, but leave a set of tapes with their Volume Pool set to "Scratch" in all the time. The weekly tape sets then get rotated back in after a period of time. Largely, this works fine. I seldom actually need the scratch tapes, but every once in a while, a backup will run over what I have dedicated to the task. However, one week's set of tapes consistently gets declined in favor of the scratch pool. The backup policies are the same for every week, they all have "Policy Volume Pool" set to "NetBackup", and all of the tapes for every week (beside the scratch tapes) have had their pools assigned as "NetBackup", definitely including the week that always gets ignored. That said, it doesn't ignore all of the NetBackup pool tapes for that week. It does usually write to two or three of them, but it writes to like 20 of the scratch tapes. (I haven't thought to look to see if it's always the same two or three tapes.) And this problem never seems to occur for any other week. It doesn't load the tapes and then reject them; it never seems to try to use them at all. They are not flagged as frozen. They are all active and unassigned when I swap them in. The tapes are in a Quantum PX510 tape library. The NetBackup server is attached to the library/robot via fibrechannel going through an HP-branded Brocade switch. I'm not an expert on NetBackup at all. I don't really even know where to look. Any advice on logs to look at or logging to enable or really anything at all would be appreciated. I'll keep an eye on the question and update it if anyone needs any more info to help.

    Read the article

  • SBD killing both cluster nodes when there are even small SAN network problems

    - by Wieslaw Herr
    I am having problems with stonith SBD in a openais-based cluster. Some background: The active/passive cluster has two nodes, node1 and node2. They are configured to provide an NFS service to users. To avoid problems with split-brain, they are both configured to use SBD. SBD is using two 1MB disks available to the hosts via an multipath fibre-channel network. The problems start if something happens with the SAN network. For example, today one of the brocade switches got rebooted and both nodes lost 2 out of 4 paths to each disks, which resulted in both nodes committing suicide and rebooting. This, of course, was highly undesirable because a) there were paths left b) even if the switch would be out for 10-20 seconds a reboot cycle of both nodes would take 5-10 minutes and all NFS-locks would be lost. I tried increasing the SBD timeout values (to 10sec+ values, dump attached at the end), however a "WARN: Latency: No liveness for 4 s exceeds threshold of 3 s" hints that something isn't working as I would it expect to. Here is what I would like to know: a) Is SBD working as it should killing nodes when 2 paths are available? b) If not, is the multipath.conf file attached correct? The storage controller we use is an IBM SVC (IBM 2145), should there be any specific configuration for it? (as in multipath.conf.defaults) c) How should I go about increasing the timeouts in SBD attachements: Multipath.conf and sbd dump (http://hpaste.org/69537)

    Read the article

  • vSphere - datastore falling off a host

    - by Chadddada
    Recently we have been running the vCheck powershell script daily in order to help in monitoring our vSphere ESX 4.0 environment. One of the oddities that we have been seeing is that some of the datastores on the SAN don't always show up on every host. Our hosts are connected redundantly, via FC, to some brocade FC switches, which then connect via fiber to our EMC Ax4 SAN. While all the datastores are presented to each host we have, and they see them initially, they sometimes seem to fall off and are no longer visible. It easy enough to rescan for datastores and add them back to the hosts the hosts but this seems to be an error. Has anyone else seen this or know why it may be happening? Responses to questions: 1. Is it always the same ESX servers that lose their connection? – Scott Warren No this happens randomly on random hosts. If a VM is running on a particular host, of which the VM's disks are on a SAN datastore, then that datastore won't disappear. It seems to happen if a host doesn't touch a datastore for a bit and it just forgets about it.

    Read the article

  • Ubuntu 10.04 & IBM DS3524 with FC multipath, inactive path is [failed][faulty] instead of [active][ghost]

    - by Graeme Donaldson
    OK, this is my setup: FC Switches IBM/Brocade, Switch1 and Switch2, independent fabrics. Server IBM x3650 M2, 2x QLogic QLE2460, 1 connected to each FC Switch. Storage IBM DS3524, 2x controllers with 4x FC ports each, but only 2x connected on each. +-----------------------------------------------------------------------+ | HBA1 Server HBA2 | +-----------------------------------------------------------------------+ | | | | | | +-----------------------------+ +------------------------------+ | Switch1 | | Switch2 | +-----------------------------+ +------------------------------+ | | | | | | | | | | | | | | | | | | | | +-----------------------------------+-----------------------------------+ | Contr A, port 3 | Contr A, port 4 | Contr B, port 3 | Contr B, port 4 | +-----------------------------------+-----------------------------------+ | Storage | +-----------------------------------------------------------------------+ My /etc/multipath.conf is from the IBM redbook for the DS3500, except I use a different setting for prio_callout, IBM uses /sbin/mpath_prio_tpc, but according to http://changelogs.ubuntu.com/changelogs/pool/main/m/multipath-tools/multipath-tools_0.4.8-7ubuntu2/changelog, this was renamed to /sbin/mpath_prio_rdac, which I'm using. devices { device { #ds3500 vendor "IBM" product "1746 FAStT" hardware_handler "1 rdac" path_checker rdac failback 0 path_grouping_policy multibus prio_callout "/sbin/mpath_prio_rdac /dev/%n" } } multipaths { multipath { wwid xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx alias array07 path_grouping_policy multibus path_checker readsector0 path_selector "round-robin 0" failback "5" rr_weight priorities no_path_retry "5" } } The output of multipath -ll with controller A as the preferred path: root@db06:~# multipath -ll sdg: checker msg is "directio checker reports path is down" sdh: checker msg is "directio checker reports path is down" array07 (xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx) dm-2 IBM ,1746 FASt [size=4.9T][features=1 queue_if_no_path][hwhandler=0] \_ round-robin 0 [prio=2][active] \_ 5:0:1:0 sdd 8:48 [active][ready] \_ 5:0:2:0 sde 8:64 [active][ready] \_ 6:0:1:0 sdg 8:96 [failed][faulty] \_ 6:0:2:0 sdh 8:112 [failed][faulty] If I change the preferred path using IBM DS Storage Manager to Controller B, the output swaps accordingly: root@db06:~# multipath -ll sdd: checker msg is "directio checker reports path is down" sde: checker msg is "directio checker reports path is down" array07 (xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx) dm-2 IBM ,1746 FASt [size=4.9T][features=1 queue_if_no_path][hwhandler=0] \_ round-robin 0 [prio=2][active] \_ 5:0:1:0 sdd 8:48 [failed][faulty] \_ 5:0:2:0 sde 8:64 [failed][faulty] \_ 6:0:1:0 sdg 8:96 [active][ready] \_ 6:0:2:0 sdh 8:112 [active][ready] According to IBM, the inactive path should be "[active][ghost]", not "[failed][faulty]". Despite this, I don't seem to have any I/O issues, but my syslog is being spammed with this every 5 seconds: Jun 1 15:30:09 db06 multipathd: sdg: directio checker reports path is down Jun 1 15:30:09 db06 kernel: [ 2350.282065] sd 6:0:2:0: [sdh] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jun 1 15:30:09 db06 kernel: [ 2350.282071] sd 6:0:2:0: [sdh] Sense Key : Illegal Request [current] Jun 1 15:30:09 db06 kernel: [ 2350.282076] sd 6:0:2:0: [sdh] <<vendor>> ASC=0x94 ASCQ=0x1ASC=0x94 ASCQ=0x1 Jun 1 15:30:09 db06 kernel: [ 2350.282083] sd 6:0:2:0: [sdh] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 Jun 1 15:30:09 db06 kernel: [ 2350.282092] end_request: I/O error, dev sdh, sector 0 Jun 1 15:30:10 db06 multipathd: sdh: directio checker reports path is down Jun 1 15:30:14 db06 kernel: [ 2355.312270] sd 6:0:1:0: [sdg] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jun 1 15:30:14 db06 kernel: [ 2355.312277] sd 6:0:1:0: [sdg] Sense Key : Illegal Request [current] Jun 1 15:30:14 db06 kernel: [ 2355.312282] sd 6:0:1:0: [sdg] <<vendor>> ASC=0x94 ASCQ=0x1ASC=0x94 ASCQ=0x1 Jun 1 15:30:14 db06 kernel: [ 2355.312290] sd 6:0:1:0: [sdg] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 Jun 1 15:30:14 db06 kernel: [ 2355.312299] end_request: I/O error, dev sdg, sector 0 Does anyone know how I can get the inactive path to show "[active][ghost]" instead of "[failed][faulty]"? I assume that once I can get that right then the spam in my syslog will end as well. One final thing worth mentioning is that the IBM redbook doc targets SLES 11 so I'm assuming there's something a little different under Ubuntu that I just haven't figured out yet. Update: As suggested by Mitch, I've tried removing /etc/multipath.conf, and now the output of multipath -ll looks like this: root@db06:~# multipath -ll sdg: checker msg is "directio checker reports path is down" sdh: checker msg is "directio checker reports path is down" xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxdm-1 IBM ,1746 FASt [size=4.9T][features=0][hwhandler=0] \_ round-robin 0 [prio=1][active] \_ 5:0:2:0 sde 8:64 [active][ready] \_ round-robin 0 [prio=1][enabled] \_ 5:0:1:0 sdd 8:48 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 6:0:1:0 sdg 8:96 [failed][faulty] \_ round-robin 0 [prio=0][enabled] \_ 6:0:2:0 sdh 8:112 [failed][faulty] So its more or less the same, with the same message in the syslog every 5 minutes as before, but the grouping has changed.

    Read the article

  • How to convert from hex-encoded string to a "human readable" string?

    - by John Jensen
    I'm using the Net-SNMP bindings for python and I'm attempting to grab an ARP cache from a Brocade switch. Here's what my code looks like: #!/usr/bin/env python import netsnmp def get_arp(): oid = netsnmp.VarList(netsnmp.Varbind('ipNetToMediaPhysAddress')) res = netsnmp.snmpwalk(oid, Version=2, DestHost='10.0.1.243', Community='public') return res arp_table = get_arp() print arp_table The SNMP code itself is working fine. Output from snmpwalk looks like this: <snip> IP-MIB::ipNetToMediaPhysAddress.128.10.200.6.158 = STRING: 0:1b:ed:a3:ec:c1 IP-MIB::ipNetToMediaPhysAddress.129.10.200.6.162 = STRING: 0:1b:ed:a4:ac:c1 IP-MIB::ipNetToMediaPhysAddress.130.10.200.6.166 = STRING: 0:1b:ed:38:24:1 IP-MIB::ipNetToMediaPhysAddress.131.10.200.6.170 = STRING: 74:8e:f8:62:84:1 </snip> But my output from the python script yields a tuple of hex-encoded strings that looks like this: ('\x00$8C\x98\xc1', '\x00\x1b\xed;_A', '\x00\x1b\xed\xb4\x8f\x81', '\x00$86\x15\x81', '\x00$8C\x98\x81', '\x00\x1b\xed\x9f\xadA', ...etc) I've spent some time googling and came across the struct module and the .decode("hex") string method, but the .decode("hex") method doesn't seem to work: Python 2.7.3 (default, Apr 10 2013, 06:20:15) [GCC 4.6.3] on linux2 Type "help", "copyright", "credits" or "license" for more information. >>> hexstring = '\x00$8C\x98\xc1' >>> newstring = hexstring.decode("hex") Traceback (most recent call last): File "<stdin>", line 1, in <module> File "/usr/lib/python2.7/encodings/hex_codec.py", line 42, in hex_decode output = binascii.a2b_hex(input) TypeError: Non-hexadecimal digit found >>> And the documentation for struct is a bit over my head.

    Read the article

  • Linux Fiber Channel Host Setup Basic

    - by Jim
    I've been googling for about 4 hours now with no luck. I am trying to setup a Linux server running Oracle Server 6.3 as a Fiber Channel host. And then connect it to a Dell Compellent Fibre Channel Host contain a 500GB Volume. The Oracle server itself contains two Brocade 815 FC HBAs. I've discovered their WWN(I think) via cat /sys/class/fc_host/host1/port_name 0x100000051efc3d85 cat /sys/class/fc_host/host2/port_name 0x100000051efc3d9f The next part is where I am at a loss. I've used iSCSI before...is FC the same deal where you have an initiator and a target? If so where do I specific that in linux? I'm also new to Fiber Channel as a protocol, so i am unsure what is needed to make a transaction? WWN and port ID? Similar to IP:Port combination in the Ethernet world. I've read alot regarding using systool, multipath, fc_transport commands, however none of these is recognized as a valid command from Oracle Server 6.3 Appreciate the guidance and assistance. I installed sccsi-target-utils and can now run rescan-scsi-bus and sg_map -x. rescan-scsi-bus.sh -l -w -r Host adapter 0 (megaraid_sas) found. Host adapter 1 ((null)) found. Host adapter 2 ((null)) found. Host adapter 3 (ata_piix) found. Host adapter 4 (ata_piix) found. Scanning SCSI subsystem for new devices and remove devices that have disappeared Scanning host 0 for SCSI target IDs 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15, LUNs 0 1 2 3 4 5 6 7 Scanning for device 0 2 0 0 .... OLD: Host: scsi0 Channel: 02 Id: 00 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning for device 0 2 1 0 ... OLD: Host: scsi0 Channel: 02 Id: 01 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 1 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 1 0 3 1 ... OLD: Host: scsi1 Channel: 00 Id: 03 Lun: 01 Vendor: COMPELNT Model: Compellent Vol Rev: 0505 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 2 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning host 3 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 3 0 0 0 ... REM: Host: scsi3 Channel: 00 Id: 00 Lun: 00 DEL: Vendor: TEAC Model: DVD-ROM DV-28SW Rev: R.2A Type: CD-ROM ANSI SCSI revision: 05 Scanning host 4 channels 0 for SCSI target IDs 0, LUNs 0 1 2 3 4 5 6 7 0 new device(s) found. 1 device(s) removed. and sg_map -x /dev/sg0 0 0 32 0 13 /dev/sg1 0 2 0 0 0 /dev/sda /dev/sg2 0 2 1 0 0 /dev/sdb /dev/sg4 1 0 3 1 0 /dev/sdc I'm not sure what this all means...

    Read the article

  • Sun Fire X4800 M2 Delivers World Record TPC-C for x86 Systems

    - by Brian
    Oracle's Sun Fire X4800 M2 server equipped with eight 2.4 GHz Intel Xeon Processor E7-8870 chips obtained a result of 5,055,888 tpmC on the TPC-C benchmark. This result is a world record for x86 servers. Oracle demonstrated this world record database performance running Oracle Database 11g Release 2 Enterprise Edition with Partitioning. The Sun Fire X4800 M2 server delivered a new x86 TPC-C world record of 5,055,888 tpmC with a price performance of $0.89/tpmC using Oracle Database 11g Release 2. This configuration is available 06/26/12. The Sun Fire X4800 M2 server delivers 3.0x times better performance than the next 8-processor result, an IBM System p 570 equipped with POWER6 processors. The Sun Fire X4800 M2 server has 3.1x times better price/performance than the 8-processor 4.7GHz POWER6 IBM System p 570. The Sun Fire X4800 M2 server has 1.6x times better performance than the 4-processor IBM x3850 X5 system equipped with Intel Xeon processors. This is the first TPC-C result on any system using eight Intel Xeon Processor E7-8800 Series chips. The Sun Fire X4800 M2 server is the first x86 system to get over 5 million tpmC. The Oracle solution utilized Oracle Linux operating system and Oracle Database 11g Enterprise Edition Release 2 with Partitioning to produce the x86 world record TPC-C benchmark performance. Performance Landscape Select TPC-C results (sorted by tpmC, bigger is better) System p/c/t tpmC Price/tpmC Avail Database MemorySize Sun Fire X4800 M2 8/80/160 5,055,888 0.89 USD 6/26/2012 Oracle 11g R2 4 TB IBM x3850 X5 4/40/80 3,014,684 0.59 USD 7/11/2011 DB2 ESE 9.7 3 TB IBM x3850 X5 4/32/64 2,308,099 0.60 USD 5/20/2011 DB2 ESE 9.7 1.5 TB IBM System p 570 8/16/32 1,616,162 3.54 USD 11/21/2007 DB2 9.0 2 TB p/c/t - processors, cores, threads Avail - availability date Oracle and IBM TPC-C Response times System tpmC Response Time (sec) New Order 90th% Response Time (sec) New Order Average Sun Fire X4800 M2 5,055,888 0.210 0.166 IBM x3850 X5 3,014,684 0.500 0.272 Ratios - Oracle Better 1.6x 1.4x 1.3x Oracle uses average new order response time for comparison between Oracle and IBM. Graphs of Oracle's and IBM's response times for New-Order can be found in the full disclosure reports on TPC's website TPC-C Official Result Page. Configuration Summary and Results Hardware Configuration: Server Sun Fire X4800 M2 server 8 x 2.4 GHz Intel Xeon Processor E7-8870 4 TB memory 8 x 300 GB 10K RPM SAS internal disks 8 x Dual port 8 Gbs FC HBA Data Storage 10 x Sun Fire X4270 M2 servers configured as COMSTAR heads, each with 1 x 3.06 GHz Intel Xeon X5675 processor 8 GB memory 10 x 2 TB 7.2K RPM 3.5" SAS disks 2 x Sun Storage F5100 Flash Array storage (1.92 TB each) 1 x Brocade 5300 switches Redo Storage 2 x Sun Fire X4270 M2 servers configured as COMSTAR heads, each with 1 x 3.06 GHz Intel Xeon X5675 processor 8 GB memory 11 x 2 TB 7.2K RPM 3.5" SAS disks Clients 8 x Sun Fire X4170 M2 servers, each with 2 x 3.06 GHz Intel Xeon X5675 processors 48 GB memory 2 x 300 GB 10K RPM SAS disks Software Configuration: Oracle Linux (Sun Fire 4800 M2) Oracle Solaris 11 Express (COMSTAR for Sun Fire X4270 M2) Oracle Solaris 10 9/10 (Sun Fire X4170 M2) Oracle Database 11g Release 2 Enterprise Edition with Partitioning Oracle iPlanet Web Server 7.0 U5 Tuxedo CFS-R Tier 1 Results: System: Sun Fire X4800 M2 tpmC: 5,055,888 Price/tpmC: 0.89 USD Available: 6/26/2012 Database: Oracle Database 11g Cluster: no New Order Average Response: 0.166 seconds Benchmark Description TPC-C is an OLTP system benchmark. It simulates a complete environment where a population of terminal operators executes transactions against a database. The benchmark is centered around the principal activities (transactions) of an order-entry environment. These transactions include entering and delivering orders, recording payments, checking the status of orders, and monitoring the level of stock at the warehouses. Key Points and Best Practices Oracle Database 11g Release 2 Enterprise Edition with Partitioning scales easily to this high level of performance. COMSTAR (Common Multiprotocol SCSI Target) is the software framework that enables an Oracle Solaris host to serve as a SCSI Target platform. COMSTAR uses a modular approach to break the huge task of handling all the different pieces in a SCSI target subsystem into independent functional modules which are glued together by the SCSI Target Mode Framework (STMF). The modules implementing functionality at SCSI level (disk, tape, medium changer etc.) are not required to know about the underlying transport. And the modules implementing the transport protocol (FC, iSCSI, etc.) are not aware of the SCSI-level functionality of the packets they are transporting. The framework hides the details of allocation providing execution context and cleanup of SCSI commands and associated resources and simplifies the task of writing the SCSI or transport modules. Oracle iPlanet Web Server middleware is used for the client tier of the benchmark. Each web server instance supports more than a quarter-million users while satisfying the response time requirement from the TPC-C benchmark. See Also Oracle Press Release -- Sun Fire X4800 M2 TPC-C Executive Summary tpc.org Complete Sun Fire X4800 M2 TPC-C Full Disclosure Report tpc.org Transaction Processing Performance Council (TPC) Home Page Ideas International Benchmark Page Sun Fire X4800 M2 Server oracle.com OTN Oracle Linux oracle.com OTN Oracle Solaris oracle.com OTN Oracle Database 11g Release 2 Enterprise Edition oracle.com OTN Sun Storage F5100 Flash Array oracle.com OTN Disclosure Statement TPC Benchmark C, tpmC, and TPC-C are trademarks of the Transaction Processing Performance Council (TPC). Sun Fire X4800 M2 (8/80/160) with Oracle Database 11g Release 2 Enterprise Edition with Partitioning, 5,055,888 tpmC, $0.89 USD/tpmC, available 6/26/2012. IBM x3850 X5 (4/40/80) with DB2 ESE 9.7, 3,014,684 tpmC, $0.59 USD/tpmC, available 7/11/2011. IBM x3850 X5 (4/32/64) with DB2 ESE 9.7, 2,308,099 tpmC, $0.60 USD/tpmC, available 5/20/2011. IBM System p 570 (8/16/32) with DB2 9.0, 1,616,162 tpmC, $3.54 USD/tpmC, available 11/21/2007. Source: http://www.tpc.org/tpcc, results as of 7/15/2011.

    Read the article

  • Das T5-4 TPC-H Ergebnis naeher betrachtet

    - by Stefan Hinker
    Inzwischen haben vermutlich viele das neue TPC-H Ergebnis der SPARC T5-4 gesehen, das am 7. Juni bei der TPC eingereicht wurde.  Die wesentlichen Punkte dieses Benchmarks wurden wie gewohnt bereits von unserer Benchmark-Truppe auf  "BestPerf" zusammengefasst.  Es gibt aber noch einiges mehr, das eine naehere Betrachtung lohnt. Skalierbarkeit Das TPC raet von einem Vergleich von TPC-H Ergebnissen in unterschiedlichen Groessenklassen ab.  Aber auch innerhalb der 3000GB-Klasse ist es interessant: SPARC T4-4 mit 4 CPUs (32 Cores mit 3.0 GHz) liefert 205,792 QphH. SPARC T5-4 mit 4 CPUs (64 Cores mit 3.6 GHz) liefert 409,721 QphH. Das heisst, es fehlen lediglich 1863 QphH oder 0.45% zu 100% Skalierbarkeit, wenn man davon ausgeht, dass die doppelte Anzahl Kerne das doppelte Ergebnis liefern sollte.  Etwas anspruchsvoller, koennte man natuerlich auch einen Faktor von 2.4 erwarten, wenn man die hoehere Taktrate mit beruecksichtigt.  Das wuerde die Latte auf 493901 QphH legen.  Dann waere die SPARC T5-4 bei 83%.  Damit stellt sich die Frage: Was hat hier nicht skaliert?  Vermutlich der Plattenspeicher!  Auch hier lohnt sich eine naehere Betrachtung: Plattenspeicher Im Bericht auf BestPerf und auch im Full Disclosure Report der TPC stehen einige interessante Details zum Plattenspeicher und der Konfiguration.   In der Konfiguration der SPARC T4-4 wurden 12 2540-M2 Arrays verwendet, die jeweils ca. 1.5 GB/s Durchsatz liefert, insgesamt also eta 18 GB/s.  Dabei waren die Arrays offensichtlich mit jeweils 2 Kabeln pro Array direkt an die 24 8GBit FC-Ports des Servers angeschlossen.  Mit den 2x 8GBit Ports pro Array koennte man so ein theoretisches Maximum von 2GB/s erreichen.  Tatsaechlich wurden 1.5GB/s geliefert, was so ziemlich dem realistischen Maximum entsprechen duerfte. Fuer den Lauf mit der SPARC T5-4 wurden doppelt so viele Platten verwendet.  Dafuer wurden die 2540-M2 Arrays mit je einem zusaetzlichen Plattentray erweitert.  Mit dieser Konfiguration wurde dann (laut BestPerf) ein Maximaldurchsatz von 33 GB/s erreicht - nicht ganz das doppelte des SPARC T4-4 Laufs.  Um tatsaechlich den doppelten Durchsatz (36 GB/s) zu liefern, haette jedes der 12 Arrays 3 GB/s ueber seine 4 8GBit Ports liefern muessen.  Im FDR stehen nur 12 dual-port FC HBAs, was die Verwendung der Brocade FC Switches erklaert: Es wurden alle 4 8GBit ports jedes Arrays an die Switches angeschlossen, die die Datenstroeme dann in die 24 16GBit HBA ports des Servers buendelten.  Das theoretische Maximum jedes Storage-Arrays waere nun 4 GB/s.  Wenn man jedoch den Protokoll- und "Realitaets"-Overhead mit einrechnet, sind die tatsaechlich gelieferten 2.75 GB/s gar nicht schlecht.  Mit diesen Zahlen im Hinterkopf ist die Verdopplung des SPARC T4-4 Ergebnisses eine gute Leistung - und gleichzeitig eine gute Erklaerung, warum nicht bis zum 2.4-fachen skaliert wurde. Nebenbei bemerkt: Weder die SPARC T4-4 noch die SPARC T5-4 hatten in der gemessenen Konfiguration irgendwelche Flash-Devices. Mitbewerb Seit die T4 Systeme auf dem Markt sind, bemuehen sich unsere Mitbewerber redlich darum, ueberall den Eindruck zu hinterlassen, die Leistung des SPARC CPU-Kerns waere weiterhin mangelhaft.  Auch scheinen sie ueberzeugt zu sein, dass (ueber)grosse Caches und hohe Taktraten die einzigen Schluessel zu echter Server Performance seien.  Wenn ich mir nun jedoch die oeffentlichen TPC-H Ergebnisse ansehe, sehe ich dies: TPC-H @3000GB, Non-Clustered Systems System QphH SPARC T5-4 3.6 GHz SPARC T5 4/64 – 2048 GB 409,721.8 SPARC T4-4 3.0 GHz SPARC T4 4/32 – 1024 GB 205,792.0 IBM Power 780 4.1 GHz POWER7 8/32 – 1024 GB 192,001.1 HP ProLiant DL980 G7 2.27 GHz Intel Xeon X7560 8/64 – 512 GB 162,601.7 Kurz zusammengefasst: Mit 32 Kernen (mit 3 GHz und 4MB L3 Cache), liefert die SPARC T4-4 mehr QphH@3000GB ab als IBM mit ihrer 32 Kern Power7 (bei 4.1 GHz und 32MB L3 Cache) und auch mehr als HP mit einem 64 Kern Intel Xeon System (2.27 GHz und 24MB L3 Cache).  Ich frage mich, wo genau SPARC hier mangelhaft ist? Nun koennte man natuerlich argumentieren, dass beide Ergebnisse nicht gerade neu sind.  Nun, in Ermangelung neuerer Ergebnisse kann man ja mal ein wenig spekulieren: IBMs aktueller Performance Report listet die o.g. IBM Power 780 mit einem rPerf Wert von 425.5.  Ein passendes Nachfolgesystem mit Power7+ CPUs waere die Power 780+ mit 64 Kernen, verfuegbar mit 3.72 GHz.  Sie wird mit einem rPerf Wert von  690.1 angegeben, also 1.62x mehr.  Wenn man also annimmt, dass Plattenspeicher nicht der limitierende Faktor ist (IBM hat mit 177 SSDs getestet, sie duerfen das gerne auf 400 erhoehen) und IBMs eigene Leistungsabschaetzung zugrunde legt, darf man ein theoretisches Ergebnis von 311398 QphH@3000GB erwarten.  Das waere dann allerdings immer noch weit von dem Ergebnis der SPARC T5-4 entfernt, und gerade in der von IBM so geschaetzen "per core" Metric noch weniger vorteilhaft. In der x86-Welt sieht es nicht besser aus.  Leider gibt es von Intel keine so praktischen rPerf-Tabellen.  Daher muss ich hier fuer eine Schaetzung auf SPECint_rate2006 zurueckgreifen.  (Ich bin kein grosser Fan von solchen Kreuz- und Querschaetzungen.  Insb. SPECcpu ist nicht besonders geeignet, um Datenbank-Leistung abzuschaetzen, da fast kein IO im Spiel ist.)  Das o.g. HP System wird bei SPEC mit 1580 CINT2006_rate gelistet.  Das bis einschl. 2013-06-14 beste Resultat fuer den neuen Intel Xeon E7-4870 mit 8 CPUs ist 2180 CINT2006_rate.  Das ist immerhin 1.38x besser.  (Wenn man nur die Taktrate beruecksichtigen wuerde, waere man bei 1.32x.)  Hier weiter zu rechnen, ist muessig, aber fuer die ungeduldigen Leser hier eine kleine tabellarische Zusammenfassung: TPC-H @3000GB Performance Spekulationen System QphH* Verbesserung gegenueber der frueheren Generation SPARC T4-4 32 cores SPARC T4 205,792 2x SPARC T5-464 cores SPARC T5 409,721 IBM Power 780 32 cores Power7 192,001 1.62x IBM Power 780+ 64 cores Power7+  311,398* HP ProLiant DL980 G764 cores Intel Xeon X7560 162,601 1.38x HP ProLiant DL980 G780 cores Intel Xeon E7-4870    224,348* * Keine echten Resultate  - spekulative Werte auf der Grundlage von rPerf (Power7+) oder SPECint_rate2006 (HP) Natuerlich sind IBM oder HP herzlich eingeladen, diese Werte zu widerlegen.  Aber stand heute warte ich noch auf aktuelle Benchmark Veroffentlichungen in diesem Datensegment. Was koennen wir also zusammenfassen? Es gibt einige Hinweise, dass der Plattenspeicher der begrenzende Faktor war, der die SPARC T5-4 daran hinderte, auf jenseits von 2x zu skalieren Der Mythos, dass SPARC Kerne keine Leistung bringen, ist genau das - ein Mythos.  Wie sieht es umgekehrt eigentlich mit einem TPC-H Ergebnis fuer die Power7+ aus? Cache ist nicht der magische Performance-Schalter, fuer den ihn manche Leute offenbar halten. Ein System, eine CPU-Architektur und ein Betriebsystem jenseits einer gewissen Grenze zu skalieren ist schwer.  In der x86-Welt scheint es noch ein wenig schwerer zu sein. Was fehlt?  Nun, das Thema Preis/Leistung ueberlasse ich gerne den Verkaeufern ;-) Und zu guter Letzt: Nein, ich habe mich nicht ins Marketing versetzen lassen.  Aber manchmal kann ich mich einfach nicht zurueckhalten... Disclosure Statements The views expressed on this blog are my own and do not necessarily reflect the views of Oracle. TPC-H, QphH, $/QphH are trademarks of Transaction Processing Performance Council (TPC). For more information, see www.tpc.org, results as of 6/7/13. Prices are in USD. SPARC T5-4 409,721.8 QphH@3000GB, $3.94/QphH@3000GB, available 9/24/13, 4 processors, 64 cores, 512 threads; SPARC T4-4 205,792.0 QphH@3000GB, $4.10/QphH@3000GB, available 5/31/12, 4 processors, 32 cores, 256 threads; IBM Power 780 QphH@3000GB, 192,001.1 QphH@3000GB, $6.37/QphH@3000GB, available 11/30/11, 8 processors, 32 cores, 128 threads; HP ProLiant DL980 G7 162,601.7 QphH@3000GB, $2.68/QphH@3000GB available 10/13/10, 8 processors, 64 cores, 128 threads. SPEC and the benchmark names SPECfp and SPECint are registered trademarks of the Standard Performance Evaluation Corporation. Results as of June 18, 2013 from www.spec.org. HP ProLiant DL980 G7 (2.27 GHz, Intel Xeon X7560): 1580 SPECint_rate2006; HP ProLiant DL980 G7 (2.4 GHz, Intel Xeon E7-4870): 2180 SPECint_rate2006,

    Read the article

1 2  | Next Page >