Search Results

Search found 5 results on 1 pages for 'bt643'.

Page 1/1 | 1 

  • Ubuntu 13.04 to 13.10 Upgrade Failed

    - by BT643
    I have a VMware virtual machine running Ubuntu 13.04, and yesterday tried to upgrade to 13.10. The install got about half way through and then everything seemed to just freeze completely. I left it going overnight to see if it was just taking a while, but this morning it was still stuck. Nothing would respond at all so I had to just murder it and force a restart with VMware. Now, when I try and boot the virtual machine back up, it just hangs forever at the Ubuntu splash screen. How can I see what's actually going on behind the scenes rather than just seeing the splash screen sit there?

    Read the article

  • Set iDRAC IP Address on Ubuntu 12.04 without Reboot?

    - by BT643
    We have a Dell PowerEdge R720XD server and want to setup iDRAC, but this is a production server so we need to do it without a reboot if possible. We just need to set the IP address on the iDRAC but the servers do not have a front LCD panel so we cannot use this. The iDRAC will currently have the default 192.168.0.120 IP address but we are not on this IP range so cannot use this. We need to change it to 192.168.5.x. I've seen racadm mentioned, but before I start messing around installing this on Ubuntu, is this what we need? and will we be able to set the IP address on the DRAC with this? Thanks

    Read the article

  • iDRAC on Dell R710 and R720

    - by BT643
    I've called Dell twice to try and clarify this basic (or so I thought) question, but I've had two different answers so far. We have a Dell R710, and a Dell R720. Does DRAC come installed by default on either? Dell said it comes build into the motherboard on the R720 but the second time I rang, they said we didn't have it. Can anyone tell me if DRAC comes as standard on the R720? I'm aware we'll need a license as well, I'm just interested in the physical capability on the server. I've never used DRAC before and know next to nothing about it, so apologies if this seems blindingly simple. Thanks

    Read the article

  • Dell PowerEdge R720 - Corrupted RAID

    - by BT643
    Apologies in advance for the lengthy question. We have a Dell PowerEdge R720 server with: 2 x 136GB SAS drives in RAID 1 for the OS (Ubuntu Server 12.04) 6 x 3TB SATA drives in RAID 5 for data A few days ago we were getting errors when trying to access files on the large RAID 5 partition. We rebooted the server and got a message about the raid controller has found a foriegn config. We've had this before, and just needed to use Dell's RAID configuration utility to import foreign config on the RAID. Last time this worked, but this time, it started doing a disk check then we got this: FSCK has returned the following: "/dev/sdb1 inode 364738 has a bad extended attribute block 7 /dev/sdb1 unexpected inconsistency run fsck manually (i.e without -a or -p options) MOUNTALL fsck /ourdatapartition [1019] terminated with status 4 MOUNTALL filesystem has errors /ourdatapartition errors where found while checking the disk drive for /ourdatapartition Press F to fix errors, I to Ignore or M for Manual Recovery" We pressed F to try and fix the errors, but it eventually errored with: Inode 275841084, i_blocks is 167080, should be 0. Fix? yes Inode 275841141 has an invalid extend node (blk 2206761006, lblk 0) Clear? yes Inode 275841141, i_blocks is 227872, should be 0. Fix? yes Inode 275842303 has an invalid extend node (blk 2206760975, lblk 0) Clear? yes .... Error storing directory block information (inode=275906766, block=0, num=2699516178): Memory allocation failed /dev/sdb1: ***** FILE SYSTEM WAS MODIFIED ***** e2fsck: aborted /dev/sdb1: ***** FILE SYSTEM WAS MODIFIED ***** mountall: fsck /ourdatapartition [1286] terminated with status 9 mountall: Unrecoverable fsck error: /ourdatapartition We noticed one of the drive lights was not lit at all, and thought this may have failed and be the problem. We replaced the drive with a spare, and tried "F" to repair it again, but we keep just getting the same error as above. In the RAID configuration utility, all drives show as "online" and "optimal". We do have this data on another replicated server, so we're not worried about "recovering" anything, we just want to get the system back online asap. The server has 64 or 32GB memory, can't remember off the top of my head, but either way, with a 14TB RAID, I think it may still not be enough. Thanks EDIT - I checked the memory usage while fsck was running as suggested and after 2 or 3 minutes, it looked like this, using up nearly all of our servers memory: When it failed after 5 minutes or so with the error in my post, the memory immediately freed up again:

    Read the article

  • New line (in the code) after <li> element breaking layout

    - by BT643
    Weirdly, I've never come across this issue before, but I've just started making a site and the top navigation isn't playing nicely. I want a small amount of white space between each menu item, but when I have new lines between my <li> elements and my <a> elements in my IDE (Netbeans), the white space disappears, yet it looks fine if I have <li><a></a></li> all on the same line. I was always under the impression html ignored white space in the code. I've checked for any weird characters causing problems in other text editors and can't find anything. Here's the code... Like this the menu looks correct but code looks ugly (I know it looks fine when it's this simple, but I'm going be adding more complexity in which makes it look awful all on one line): <ul id="menu"> <li><a href="#">About</a></li> <li class="active"><a href="<?php echo site_url("tracklist"); ?>">Track List</a></li> <li><a href="<?php echo site_url("stats"); ?>">Stats</a></li> <li><a href="#">Stats</a></li> </ul> Like this the menu looks wrong but code looks fine: <ul id="menu"> <li> <a href="#">About</a> </li> <li class="active"> <a href="<?php echo site_url("tracklist"); ?>">Track List</a> </li> <li> <a href="<?php echo site_url("stats"); ?>">Stats</a> </li> <li> <a href="#">Stats</a> </li> </ul> Here's the css: #menu { float: right; } #menu li { display: inline-block; padding: 5px; background-color: #932996; border-bottom: solid 1px #932996; } #menu li:hover { border-bottom: solid 3px #FF0000; } #menu li.active { background-color: #58065e; } I'm sure it's something simple I'm doing wrong... but can someone shed some light on this for me? Sorry for the lengthy post (my first on stackoverflow).

    Read the article