Search Results

Search found 9 results on 1 pages for 'chopper3'.

Page 1/1 | 1 

  • Cisco FC SAN switch decision

    - by Chopper3
    I've got to buy a bunch of FC SAN switches in the next week or so, I have to, and want to, buy Cisco MDSs. Servers are HP BL490c G6's in C7000 chassis with Virtual-Connect Flex-10 ethernet interconnects and VC FC interconnects (Emulex HBAs btw), all running ESX 3.5U4 (for now). I think I've only really got two choices; MDS 9509's with dual-supervisors with a single 48-port 4Gb FC card MDS 9222i's with single supervisor and the built-in 18-FC-port/4-GigE-FCIP-port option Both have the same functionality (I think, buying the enterprise licence btw), both have plenty enough performance and adequate ports for now and the next three years. The 9222i's are about 55% the price of the 9509's - logic says get the 'i's but will I really miss the dual-supervisors? I've got lots of 9509's with dual-supervisors that I'm very happy with but I'm not sure I've every benefitted from the dual-sups in the past and they are nearly twice the price - but if I don't buy them and miss them I can't retrofit them later. What are your thoughts?

    Read the article

  • Is vSphere's Data Recover appliance 'production-ready'?

    - by Chopper3
    I have a smallish lab environment (16 x ESX4iU1 hosts and VC4U1) that I periodically want to backup. Normally in production we snap to secondary SAN boxes then have disk-based VTL backups via NetBackup which eventually migrate to off-site removable disks but this seems like an overkill for my own kit. I've spent a bit of time with vSphere's 'Data Recovery' appliance, it was easy enough to setup and I've not really ran into any issues with it but that doesn't mean I trust it fully. Have you had any experiences with it, positive or negative that would help me decide whether to trust it or pay Symantec for more licences? Thank you in advance.

    Read the article

  • Methodologies for performance-testing a WAN link

    - by Chopper3
    We have a pair of new diversely-routed 1Gbps Ethernet links between locations about 200 miles apart. The 'client' is a new reasonably-powerful machine (HP DL380 G6, dual E56xx Xeons, 48GB DDR3, R1 pair of 300GB 10krpm SAS disks, W2K8R2-x64) and the 'server' is a decent enough machine too (HP BL460c G6, dual E55xx Xeons, 72GB, R1 pair of 146GB 10krpm SAS disks, dual-port Emulex 4Gbps FC HBA linked to dual Cisco MDS9509s then onto dedicated HP EVA 8400 with 128 x 450GB 15krpm FC disks, RHEL 5.3-x64). Using SFTP from the client we're only seeing about 40Kbps of throughput using large (2GB) files. We've performed server to 'other local server' tests and see around 500Mbps through the local switches (Cat 6509s), we're going to do the same on the client side but that's a day or so away. What other testing methods would you use to prove to the link providers that the problem is theirs?

    Read the article

  • Faster, secure, protocol/code required for long-distance transfer.

    - by Chopper3
    I've ran into a problem and I'm looking for a new secure protocol/client/server that's faster over a 1Gb/s fibre link - let me tell you the story... I have a pair of redundant, diversely-routed, 1Gb/s links over a distance of around 250 miles or so (not dark fibre but a dedicated point to point link, not a mesh). At the 'client' end I have a HP DL380 G5 (2 x dual-core 2.66Ghz Xeon's, 4GB, Windows 2003EE 32-bit), at the 'server' end I have a HP BL460c G6 (2 x quad-core 2.53Ghz Xeons, 48GB, Oracle Linux 5.3 64-bit). I need to transfer around 500 x 2GB files per week from the client to the server machines per week - but the transfer NEEDS to be secure. Using both iPerf or regular FTP I can get ~80MB/s of transfer pretty consistently, which is great. Using WinSCP or Windows SFTP I can't seem to get more that ~3-4MB/s, at this point the server's CPU is 3% busy while CPU0 of the client goes to ~30% utilised. We've tried editing various TCP window sizes with little success. Both ends are connected to quite low-usage Cisco Cat6509's with Sup720's. I can replace the client machine with a newer machine and/or move it to Linux - but this will take time. Clearly these single-threaded secure Windows clients are introducing too much latency doing their encryption. So a few questions/thoughts; Are there any higher performing secure protocols or client software for Windows that I could try? I'm pretty protocol-gnostic so long as it'll work between Windows and Linux. Should I be using hardware to do the encryption, either in the client or the network parts? If so what would you recommend? I'm not convinced that just swapping the server would be that much faster, the CPU was only at 30% but then again that's higher than I'd have expected given the load - moving to Linux at the client end may be a better idea but would be quite disruptive. Am I missing a trick? Thanks in advance.

    Read the article

  • Slower/cached Linux file system required

    - by Chopper3
    I know it sounds odd but I need a slower or cached filesystem. I have a lot of firewalls that are syslog'ing their data to a pair of Linux VMs which write these files to their 'local' (actually FC SAN attached) ext3-formatted disks and also forward the messages to our Splunk servers. The problem is that the syslog server is writing these syslog messages as hundreds, sometimes thousands, of tiny ~4k writes per second back to our FC SAN - which can handle this workload right now but our FW traffic's going to be growing by at least a factor of 5000% (really) in coming months and that'll be a pain for the SAN, I want to fix the root cause before it's a problem. So I need some help figuring out a way of getting these writes cached or held-off in some way from the 'physical' disks so that the VMs fire off larger, but less frequent, writes - there's no way of avoiding these writes but there's no need for it to do so many tiny ones. I've looked at the various ext3 options, setting noatime and nodiratime but that's not made much of a dent in the problem. Obviously I'm investigating other file systems but thought I'd throw this out in case others have the same problem in the future. Oh and I can't just forward these messages to Splunk, our firewall team insist they're in their original format for diag purposes.

    Read the article

  • What IT tasks have you found in your career to be just painful

    - by Chopper3
    We always try to be clever and script everything that we find repetitive but not everything can be automated - what have you found in your career to be just a massive pain? I'll give you mine - building Netware version 2.xx on 5.25" disks with multiple NICs - this often took HOURS of swapping disks, pacing around, swapping disks, more pacing etc. Then finally it would hopefully work - if you'd not set the IRQs/DMAs right you had to start again, wow I loved version 3 which didn't need all that. What about you?

    Read the article

  • Can I move a copy of Windows 7 from one machine to another?

    - by Chopper3
    This is a pretty basic question sorry but I've looked in the 'related questions' and couldn't find an answer. When Windows 7 came out I bought a copy of Home Premium, the retail box with both 32 and 64 bit versions, to install via Boot Camp on my macbook. I've just got a retail (32 and 64 bit) copy of Windows 7 Ultimate that I'd like to install instead-of/over the Home Premium version and it struck me that I should, at least in principal be able to install the Home Premium version on my son's machine - is this the case and if so is there anything I should do first or once they're installed to let MS know I'm being a good guy about this? Sorry it's such a dim question but I'm a serverfault guy really and know very little about Windows. Thanks.

    Read the article

  • (Mac Intel) HP PS driver prints in B&W from Adobe Reader after installing Cannon PS driver

    - by JohnB
    I have a unique problem that leaves me at a loss as to where to start troubleshooting. We have three Macs we use for graphics, two of which are PowerPC and one which is Intel. They are set up to print to an HP 5500dn, but occasionally this printer gets tied up with a massive print job, so I installed the PS driver (iR-PSv1.81MacOSX) for the Cannon C3200 Printer/copier on each of the machines. Both of the PowerPC Macs installed without issue, but the Intel Mac exhibits strange behavior: I've confirmed that while the Cannon driver is installed (whether or not the Cannon is set up for printing in print settings), the HP 5500dn will print in color from Safari, but only prints in black and white from Adobe Reader. The Cannon printer itself has not exhibited any strange behavior As soon as the Cannon driver is uninstalled, the HP 5500dn prints in color from Adobe Reader again. We run a network of Windows PCs, and the 'Mac room' mostly takes care of itself, so we don't have any experienced Mac administrators onsite. The Cannon is capable of Appletalk, but the PS driver seemed easier to work with (and Appletalk is currently disable on the Cannon. I'm not against using the Appletalk compatible drivers, but I would rather use the PS driver if at all possible - I don't want to open up the proverbial can of worms. If someone has any clues or suggestions that would help troubleshoot this problem, I would be grateful. I've already done some googling, but due to the obscure nature of this problem, I haven't been very successful. I don't like to create multiple threads on multiple sites, but I'm posting here due to Chopper3's suggestion on my post on ServerFault (http://serverfault.com/questions/135349/mac-intel-hp-ps-driver-prints-in-bw-from-adobe-reader-after-installing-cannon)

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

1