  • Triple-head on a Lenovo T520

    - by codeape
    Lenovo T520 with integrated Intel HD graphics + a NVidia card (Optimus) Ubuntu 11.10 on the computer. I would like to use the built-in screen plus two external screens. This PDF indicates that it is possible to connect up to four external monitors to the laptop. The information is Windows only. I was planning to disable the NVidia card, since I have read that Linux support for Optimus is not good. Questions: Has anyone set up three monitors on NVidia hardware? Has anyone set up three monitors using Intel HD 3000? Can I expect it to work out of the box, or are there tricks I need to be aware of?

    Read the article

  • DNS "recursion not available" using a Cisco AnyConnect VPN connection

    - by codeape
    Does anyone have experience with configuring Cisco AnyConnect VPN? We have a problem with client DNS name resolution when connected over VPN. To me, it looks as if the Cisco AnyConnect VPN client intercepts DNS queries from the clients. Can someone confirm that the AnyConnect VPN client in fact does this (intercepts DNS traffic)? Where is this configured on the VPN server? EDIT: Here's how the routing table changes when I connect to the VPN: [~] $ diff -u /tmp/route_normal /tmp/route_vpn --- /tmp/route_normal 2010-01-20 19:23:47.000000000 +0100 +++ /tmp/route_vpn 2010-01-20 19:24:46.000000000 +0100 @@ -1,6 +1,10 @@ Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface +xxx.xxx.xx.xx.i 10.0.0.1 255.255.255.255 UGH 0 0 0 ath0 172.16.53.0 * 255.255.255.0 U 0 0 0 vmnet1 10.0.0.0 * 255.255.255.0 U 0 0 0 ath0 +172.17.20.0 * 255.255.255.0 U 0 0 0 cscotun 0 +192.168.111.0 172.17.20.212 255.255.255.0 UG 0 0 0 cscotun 0 172.16.140.0 * 255.255.255.0 U 0 0 0 vmnet8 +172.16.0.0 172.17.20.212 255.255.0.0 UG 0 0 0 cscotun 0 default 10.0.0.1 0.0.0.0 UG 0 0 0 ath0 EDIT 2: The IT guy has done "something" on the VPN endpoint. Now I get "recursion not available" when doing nslookup. The DNS servers have recursion enabled. So it must be the Cisco VPN DNS interception messing this up. ubuntu@domU-12-31-39-00-ED-14:~$ /opt/cisco/vpn/bin/vpn connect xxx.xxxxxx.xx ... >> Please enter your username and password ... >> notice: Establishing VPN... >> state: Connected >> notice: VPN session established to ... ubuntu@domU-12-31-39-00-ED-14:~$ nslookup www.vg.no ;; Got recursion not available from ..., trying next server ;; Got recursion not available from ..., trying next server ;; Got recursion not available from ..., trying next server ;; Got recursion not available from ..., trying next server Server: 172.16.0.23 Address: 172.16.0.23#53 ** server can't find www.vg.no.compute-1.internal: REFUSED ubuntu@domU-12-31-39-00-ED-14:~$ ping 195.88.55.16 PING 195.88.55.16 (195.88.55.16) 56(84) bytes of data. 64 bytes from 195.88.55.16: icmp_seq=1 ttl=240 time=110 ms 64 bytes from 195.88.55.16: icmp_seq=2 ttl=240 time=111 ms 64 bytes from 195.88.55.16: icmp_seq=3 ttl=240 time=109 ms ^C --- 195.88.55.16 ping statistics --- 3 packets transmitted, 3 received, 0% packet loss, time 2017ms rtt min/avg/max/mdev = 109.953/110.379/111.075/0.496 ms

    Read the article

  • How to interrupt stuck bash tab completion?

    - by codeape
    Case: A Windows share mounted using samba over a flaky VPN connection (sometimes very slow, sometimes it drops) When doing tab-completion on filenames, my bash shell can freeze up if the VPN is slow or dropped when I am attempting the tab completion. Example: $ cp myfile.zip /mnt/winbox-c/Progr<tab> key pressed here Is there a bash key I can press to get bash out of its hung state when something like this happens?

    Read the article

  • How many hours of use before I need to clean a tape drive?

    - by codeape
    I do backups to a HP Ultrium 2 tape drive (HP StorageWorks Ultrium 448). The drive has a 'Clean' LED that supposedly will light up or blink when the drive needs to be cleaned. The drive has been in use since october 2005, and still the 'Clean' light has never been lit. The drive statistics are: Total hours in use: 1603 Total bytes written: 19.7 TB Total bytes read: 19.3 TB My question is: How many hours of use can I expect before I need to clean the drive? Edit: I have not encountered any errors using the drive. I do restore tests every two months, and every backup is verified. Edit 2: The user manual says: "HP StorageWorks Ultrium tape drives do not require regular cleaning. An Ultrium universal cleaning cartridge should only be used when the orange Clean LED is flashing." Update: It is now May 2010 (4.5 years of use), and the LED is still off, I have not cleaned, backups verify and regular restore tests are done.

    Read the article

  • Is it safe to have NVidia graphics always on on a Linux laptop, or do I risk overheating?

    - by codeape
    I'm getting a Lenovo T520 with two graphics cards: Integrated Intel HD 3000 Discrete NVidia NVS 4200M In BIOS, I can adjust which card(s) to use: Integrated only Discrete only Both (NVidia optimus) Since optimus is not well supported under Linux, I wonder if it is OK to set up the system to use the NVidia card all the time. I have read somewhere that a laptop risks overheating if using a discrete graphics card all the time. Is this true? Does someone have any experience to share?

    Read the article

  • How many hours of use before I need to clean a tape drive?

    - by codeape
    I do backups to a HP Ultrium 2 tape drive (HP StorageWorks Ultrium 448). The drive has a 'Clean' LED that supposedly will light up or blink when the drive needs to be cleaned. The drive has been in use since october 2005, and still the 'Clean' light has never been lit. The drive statistics are: Total hours in use: 1603 Total bytes written: 19.7 TB Total bytes read: 19.3 TB My question is: How many hours of use can I expect before I need to clean the drive? Edit: I have not encountered any errors using the drive. I do restore tests every two months, and every backup is verified. Edit 2: The user manual says: "HP StorageWorks Ultrium tape drives do not require regular cleaning. An Ultrium universal cleaning cartridge should only be used when the orange Clean LED is flashing." Update: It is now May 2010 (4.5 years of use), and the LED is still off, I have not cleaned, backups verify and regular restore tests are done.

    Read the article

  • SQLAlchemy session management in long-running process

    - by codeape
    Scenario: A .NET-based application server (Wonderware IAS/System Platform) hosts automation objects that communicate with various equipment on the factory floor. CPython is hosted inside this application server (using Python for .NET). The automation objects have scripting functionality built-in (using a custom, .NET-based language). These scripts call Python functions. The Python functions are part of a system to track Work-In-Progress on the factory floor. The purpose of the system is to track the produced widgets along the process, ensure that the widgets go through the process in the correct order, and check that certain conditions are met along the process. The widget production history and widget state is stored in a relational database, this is where SQLAlchemy plays its part. For example, when a widget passes a scanner, the automation software triggers the following script (written in the application server's custom scripting language): ' wiget_id and scanner_id provided by automation object ' ExecFunction() takes care of calling a CPython function retval = ExecFunction("WidgetScanned", widget_id, scanner_id); ' if the python function raises an Exception, ErrorOccured will be true ' in this case, any errors should cause the production line to stop. if (retval.ErrorOccured) then ProductionLine.Running = False; InformationBoard.DisplayText = "ERROR: " + retval.Exception.Message; InformationBoard.SoundAlarm = True end if; The script calls the WidgetScanned python function: # pywip/functions.py from pywip.database import session from pywip.model import Widget, WidgetHistoryItem from pywip import validation, StatusMessage from datetime import datetime def WidgetScanned(widget_id, scanner_id): widget = session.query(Widget).get(widget_id) validation.validate_widget_passed_scanner(widget, scanner) # raises exception on error widget.history.append(WidgetHistoryItem(timestamp=datetime.now(), action=u"SCANNED", scanner_id=scanner_id)) widget.last_scanner = scanner_id widget.last_update = datetime.now() return StatusMessage("OK") # ... there are a dozen similar functions My question is: How do I best manage SQLAlchemy sessions in this scenario? The application server is a long-running process, typically running months between restarts. The application server is single-threaded. Currently, I do it the following way: I apply a decorator to the functions I make avaliable to the application server: # pywip/iasfunctions.py from pywip import functions def ias_session_handling(func): def _ias_session_handling(*args, **kwargs): try: retval = func(*args, **kwargs) session.commit() return retval except: session.rollback() raise return _ias_session_handling # ... actually I populate this module with decorated versions of all the functions in pywip.functions dynamically WidgetScanned = ias_session_handling(functions.WidgetScanned) Question: Is the decorator above suitable for handling sessions in a long-running process? Should I call session.remove()? The SQLAlchemy session object is a scoped session: # pywip/database.py from sqlalchemy.orm import scoped_session, sessionmaker session = scoped_session(sessionmaker()) I want to keep the session management out of the basic functions. For two reasons: There is another family of functions, sequence functions. The sequence functions call several of the basic functions. One sequence function should equal one database transaction. I need to be able to use the library from other environments. a) From a TurboGears web application. In that case, session management is done by TurboGears. b) From an IPython shell. In that case, commit/rollback will be explicit. (I am truly sorry for the long question. But I felt I needed to explain the scenario. Perhaps not necessary?)

    Read the article

  • Connect to a running instance of Visual Studio 2003 using COM, build and read output

    - by codeape
    For Visual Studio 6.0, I can connect to a running instance like: o = GetActiveObject("MSDev.Application") What prog ID do I use for Visual Studio 2003? How do I execute a 'Build Solution' once I have the COM object that references the VS2003 instance? How do I get the string contents of the build output window after executing the build solution command? Yes, I am aware that I can build a solution from the command line. But in this case, I need to connect to a running instance of Visual Studio. EDIT: found and submitted an answer, see below.

    Read the article

  • Create a custom worksheet function in Excel VBA

    - by Tomalak
    I have a faint memory of being able to use VBA functions to calculate values in Excel, like this (as the cell formula): =MyCustomFunction(A3) Can this be done? EDIT: This is my VBA function signature: Public Function MyCustomFunction(str As String) As String The function sits in the ThisWorkbook module. If I try to use it in the worksheet as shown above, I get the #NAME? error. Solution (Thanks, codeape): The function is not accessible when it is defined ThisWorkbook module. It must be in a "proper" module, one that has been added manually to the workbook.