Search Results

Search found 69 results on 3 pages for 'cscript'.

Page 1/3 | 1 2 3  | Next Page >

  • cscript - print output on same line on console?

    - by Guy
    If I have a cscript that outputs lines tothe screen, how do I avoid the "line feed" after each print? Example: for a = 1 to 10 print "." REM (do something) next The expected output should be: .......... Not: . . . . . . . . . . In the past I've used to print the "up arrow character" ASCII code. Can this be done in cscript?

    Read the article

  • cscript - Invalid procedure call or argument when running a vbs file

    - by quanta
    I've been trying to use check_time.vbs to check the Windows time. Here's the script: http://pastebin.com/NfUrCAqU The help message could be display: C:\Program Files\NSClient++\scripts>cscript //NoLogo check_time.vbs /? check_time.vbs V1.01 Usage: cscript /NoLogo check_time.vbs serverlist warn crit [biggest] Options: serverlist (required): one or more server names, coma-separated warn (required): warning offset in seconds, can be partial crit (required): critical offset in seconds, can be partial biggest (optional): if multiple servers, else use default least offset Example: cscript /NoLogo check_time.vbs myserver1,myserver2 0.4 5 biggest But I get the following error when running: C:\Program Files\NSClient++\scripts>cscript //NoLogo check_time.vbs 0.asia.pool.ntp.org 20 50 C:\Program Files\NSClient++\scripts\check_time.vbs(53, 1) Microsoft VBScript run time error: Invalid procedure call or argument The screenshot: Manually execute w32tm still works fine: What might be the cause of this?

    Read the article

  • Can I pass an argument to a VBScript (vbs file launched with cscript)?

    - by Peter
    I have this script saved in "test.vbs": Set FSO = CreateObject("Scripting.FileSystemObject") Set File = FSO.OpenTextFile(workFolder &"\test.txt", 2, True) File.Write "testing" File.Close Set File = Nothing Set FSO = Nothing Set workFolder = Nothing When I run the script I want to pass the value of the "workFolder" variable. How can I do this? Can I do it? Something like "cscript test.vbs workFolder:'C:\temp\'" perhaps? Bonus question: Is it neccessary to clean up the passed variable with "Set workFolder = Nothing" or does VBSCript do that automatically when it terminates? Maybe "Set File = Nothing" and "Set FSO = Nothing" is unneccessary also? Please let me know if you know the answer to both these questions.

    Read the article

  • How to solve "catastrophic failure" with 32-bit COM component in SysWOW64\cscript or wscript

    - by kcrumley
    I'm trying to run a VBScript script that uses a 7-year-old 3rd-party 32-bit COM component on Windows Server 2008 R2, with the command-line 32-bit script host, SysWOW64\cscript.exe. When I call CreateObject on the class, it appears to be successful, but the very first time I try to use a property or method (I've tried several different ones) on the object, it gives me the "catastrophic failure". I have identical results with SysWOW64\wscript.exe, except, of course, that my error message comes in a msgbox instead of the command-line window. I think this has to do specifically with the 64-bit scripting hosts because of the following: The equivalent Classic ASP script, calling the same component and using 95% of the same code, works correctly on the same server, with IIS configured to support 32-bit COM. The same VBScript works correctly on a 32-bit Windows XP machine and a 32-bit Windows Server 2003 machine. The component fails in exactly the same way on my 64-bit Windows 7 machine. My Google searches for solutions to this problem have mostly turned up a lot of different problems that were solved by putting the COM component into a toolbar in Visual Studio. Obviously, that solution doesn't apply here. My questions are: Is there a core problem that is always behind a "catastrophic failure" from a Windows scripting host calling a COM component? Is there a place in a configuration snap-in, or in the registry, where I need to make a change similar to the change I had to make to the IIS Application pool to "Enable 32-bit Applications"? Is there a general place in the Server 2008 R2 Event Viewer that I should be looking, to see if there are any more details on the failure, in case it turns out to be specific to this component? Thanks in advance.

    Read the article

  • Batch file conversion to vbscript

    - by blademasterson
    I need to convert a batch file to vbscript but am unfamiliar with both. If I can understand what is going on in the batch file I can work out the vbscript easy enough. Problem is the batch file runs a few cscript commands which is supposed to have a syntax of cscript [script name] [host options] [script arguments] However whomever wrote the batch file doesn't use it in a standard manner so if someone could explain the use of the command I can work out the rest. Sample line: Filename and actual url's removed for safety sake cscript file.vbs -a -r url -h url -o raw

    Read the article

  • Trying to run psexec to remote to server and recycle app pool

    - by James
    If I run this from my command prompt it works fine. psexec \ServerName cscript.exe iisapp.vbs /a AppName /r I'm trying to do the same thing with C# console app. I'm using the below code but most of the time the application hangs and doesn't complete, and the few times it does it throws an error code. Am I doing this wrong? Anyone know where I can look up the error or error code? static void RecycleAppPool(string sServer) { Console.Clear(); ProcessStartInfo p = new ProcessStartInfo("psexec.exe", "\\\\" + sServer + " cscript.exe iisapp.vbs /a <AppName> /r"); p.RedirectStandardInput = true; p.UseShellExecute = false; Process.Start(p); } When it completes with error, looks like this "cscript.exe exited with error code -2147024664"

    Read the article

  • Task Scheduler not able to execute .vbs scripts successfully

    - by Django Reinhardt
    Apologies if this has a really obvious answer! We have several daily tasks we run via a .vbs script on our server (through the Task Scheduler), and for months it has been fine, but recently we've hit a problem. The .vbs scripts stopped successfully executing (always timing out)... but could still be executed manually with no problems(!). Not knowing any good reason why the Task Scheduler should start having problems, we thought we'd try a little "creative thinking", and run the .vbs another way: Via a .bat file executed by the Task Scheduler. Again we hit weird issues, but with a little more debugging information, this time around. The .bat file run by Task Scheduler is nothing more than... CScript "C:\location\script.vbs" > Log.txt But after an attempt to run it, the Task Scheduler fails with the following error: 0x1: An incorrect function was called or an unknown function was called. The Log.txt (as output from the .bat file above) says: CScript Error: Initialization of the Windows Script Host failed. (Not enough storage is available to process this command. ) But get this: The .bat file executes perfectly (vbs script and all) if it's executed with a double click! There's only a problem when it's run by Task Scheduler. What the hell? We're running Windows Server 2008 R2 (x64) and yes, the Task Sheduler's results are the same whether the user is logged in or not. Also, the user that can run the scripts successfully manually, is also the same user that runs the scripts in Task Scheduler. Thanks for any help for this weird problem!

    Read the article

  • Task Scheduler not able to execute .vbs successfully

    - by Django Reinhardt
    Hi there, got this weird problem, which will hopefully have an obvious solution for some enlightened soul: We have several daily tasks we run via a .vbs script on our server (through the Task Scheduler), and for months it has been fine, but recently we've hit a problem. The .vbs script stopped successfully executing... but oddly it worked fine when ran manually! The error given in these circumstances was always "Timeout". We thought we try a little creative thinking, and run the .vbs another way: Via a .bat file. Again we hit weird issues, but with a little more debugging information, this time around. The .bat file is nothing more than... CScript "C:\location\script.vbs" > Log.txt But the Task Scheduler fails with the following error: 0x1: An incorrect function was called or an unknown function was called. The log.txt file says: CScript Error: Initialization of the Windows Script Host failed. (Not enough storage is available to process this command. ) But get this: The .bat file executes perfectly (vbs script and all) if it's executed with a double click! There's only a problem when it's run by Task Scheduler. What the hell? We're running Windows Server 2008 R2 (x64) and yes, the Task Sheduler's results are the same whether the user is logged in or not. Also, the user that can run the scripts successfully manually, is also the same user that runs the scripts in Task Scheduler. Thanks for any help for this weird problem!

    Read the article

  • svn dump fails with WScript.Shell

    - by chandrajeet
    var WshShell = new ActiveXObject("WScript.Shell"); var commandLine = "svnadmin dump " + repoFullPath + " > " + repoName + ".dumpfile"; WshShell.Exec(commandLine) I am trying to run above cscript in windows but it seems like, it's doing nothing. It doesn't create the dump file. Any mistake that I am doing? Thanks,

    Read the article

  • Script to download file and rename according to date on Windows Vista machine?

    - by Dave
    Hi, I need to daily run a script that will download a file from a fixed location and save it on my computer with an appropriate filename-YYYYMMDD-HHSS.ext timestamp. I need a historical record of what that file was at that particular time. I can manually check and see what the changes were, so compairson not needed. (I was looking for an online service that would do this for me, but I think a locally running script on my machine would be good enough). Although i do have php on my machine, i would prefer if its a pure windows builtin solution, just in case i have to (likely) adapt it to someone else's system (non-techies). If someone has something like this and can contribute the code - help would be most appreciated!! D

    Read the article

  • File permissions with FileSystemObject - CScript.exe says one thing, Classic ASP says another...

    - by Dylan Beattie
    I have a classic ASP page - written in JScript - that's using Scripting.FileSystemObject to save files to a network share - and it's not working. ("Permission denied") The ASP page is running under IIS using Windows authentication, with impersonation enabled. If I run the following block of code locally via CScript.exe: var objNet = new ActiveXObject("WScript.Network"); WScript.Echo(objNet.ComputerName); WScript.Echo(objNet.UserName); WScript.Echo(objNet.UserDomain); var fso = new ActiveXObject("Scripting.FileSystemObject"); var path = "\\\\myserver\\my_share\\some_path"; if (fso.FolderExists(path)) { WScript.Echo("Yes"); } else { WScript.Echo("No"); } I get the (expected) output: MY_COMPUTER dylan.beattie MYDOMAIN Yes If I run the same code as part of a .ASP page, substituting Response.Write for WScript.Echo I get this output: MY_COMPUTER dylan.beattie MYDOMAIN No Now - my understanding is that the WScript.Network object will retrieve the current security credentials of the thread that's actually running the code. If this is correct - then why is the same user, on the same domain, getting different results from CScript.exe vs ASP? If my ASP code is running as dylan.beattie, then why can't I see the network share? And if it's not running as dylan.beattie, why does WScript.Network think it is?

    Read the article

  • Permanent remove of logo in Windows Scripting Host (WSH() scripts.

    - by antonio
    I know two ways to remove the logo permanently. The "official" one: cscript //Nologo //S Will save current command line options for current user. A ftype approach with admin privileges: ftype wsffile="%SystemRoot%\System32\CScript.exe" //nologo "%%1" %%* ftype jsfile="%SystemRoot%\System32\CScript.exe" //nologo "%%1" %%* ftype vbsfile="%SystemRoot%\System32\CScript.exe" //nologo "%%1" %%* Double-%'s are needed only if you use the lines in a batch file. The latter will all users via affect the reg key HKEY_CLASSES_ROOT\<file>\Shell\Open\Command, where <file> can be wsffile, jsfile or vbsfile. Do you know where are stored the cscript //Nologo //S settings?

    Read the article

  • BizTalk 2009 - BizTalk Benchmark Wizard: Installation

    - by StuartBrierley
    As previously detailed, I have completed a single server installation of BizTalk Server 2009 standard on my development laptop; a MacBook Pro Core2Duo running at 2.16Ghz with 2Gb of RAM.  Following this I also posted on my use of the BizTalk Server Best Practices Anaylser and how to configure the BizTalk SQL Server Jobs.  All of which means that I should have some confidence that I have a decent working BizTalk Server 2009 environment, Next I thought that it would be a good idea to try and get some idea of how this setup performs by carrying out some baseline tests that can then be replicated on the test and live servers. The aim of this would be to allow confident predictions to be made of how any solutions developed on a single "server" installation may be expected to perform when deployed to these multi-server BizTalk Server 2009 standard installations. The BizTalk Benchmark Wizard would seem to be the perfect tool for the job. The BizTalk Benchmark Wizard is a ultility that can be used to gain some validation of a BizTalk installation, giving a level of guidance on whether it is performing as might be expected. This utility should be used after BizTalk Server has been installed and before any solutions are deployed to the environment.  This will ensure that you are getting consistent and clean results from the BizTalk Benchmark Wizard. The BizTalk Benchmark Wizard applies load to the BizTalk Server environment under a choice of specific scenarios. During these scenarios performance counter information is collected and assessed against statistics that are appropriate to the BizTalk Server environment: "The executed scenarios may or may not be relative to any realistic scenario, and is only intended for testing. The BizTalk Benchmark Wizard has been developed in relation to the BizTalk Server 2009 Scale Out Testing Study. More information about the study can be found here: http://msdn.microsoft.com/en-us/library/ee377068(BTS.10).aspx" After downloading and installing the wizard you will need set up the Hosts, Instances and Adapter handlers.  This is done by running a script file using the “cscript” detailed below.  To do this you will need to open a command prompt window and navigate to the script folder; assuming the default installation location this would be C:\Program Files\Blogical\BizTalk Benchmark Wizard\Artefacts\BizTalk. In this folder you should find an InstallHosts.vbs file which can be executed using the following parameters: NTGroupName - The name of the Windows NT group. UserName – The name of the user account running the service instances. Password – The password of the user account running the service instances. Receive Host – The name of the server where you want to run the receive host instance.  Send Host - The name of the server where you want to run the sen host instance. Processing Host - The name of the server where you want to run the process host instance. By default the script is set up for 64 bit hosts, so if you are running in 32 bit environment make sure that you change the following line in the script before continuing: from:   objHS.IsHost32BitOnly = False to:    objHS.IsHost32BitOnly = True If you have a single box installation, your script command might look like this: cscript InstallHosts.vbs "BizTalk Application Users" “\MyUser” “MyPassword” “BtsServer1” “BtsServer1” “BtsServer1” If you have a multi server installation, your script command might look like this: cscript InstallHosts.vbs "MyDomain\BizTalk Application Users" “MyDomain\MyUser” “MyPassword” “BtsServer1” “BtsServer2” “BtsServer2” Running this script will create: Three hosts (BBW_RxHost, BBW_TxHost and BBW_PxHost) Three host instances One send and one receive adapter handler for the WCF NetTcp adapter. You will then need to import the BizTalk MSI via the BizTalk Administration Console.  Open the BizTalk Administration Console, point to the “Applications” node and import the BizTalk Benchmark Wizard.msi found in the same folder as the script above. This will create a “BizTalk Benchmark Wizard” application along with all ports and orchestrations needed. To finish the installation you will need to run the BizTalk Benchmark Wizard.msi on all BizTalk servers to add the assemblies to the Global Assembly Cache (GAC). Next I will look at running the BizTalk Benchmark Wizard.

    Read the article

  • PostgreSQL service doesn't start on Windows 7

    - by Mehrdad
    (Not sure if this should be on Stack Overflow or Super User... please move if needed.) When I start the PostgreSQL service on Windows 7 x64, it immediately stops. When I check my log folder (C:\PostgreSQL\9.1\data\pg_log\), I see new but empty log files. The Event Viewer doesn't tell me anything other than the fact that the server did not respond. I've even tried turning off my firewall (I don't have any antivirus or anything else), but nothing helps. The setup works fine when I'm on Windows XP (32-bit) (same computer, different partition). I can't figure out what's wrong, even though I've tried tracing the system calls. Is PostgreSQL compatible with Windows 7 x64 at all? Any ideas what the issue might be? More info: This problem also happens at the end of installation -- the service starts, then stops immediately, before the installer can do anything. Installation log: Starting the database server... Executing cscript //NoLogo "C:\Program Files\PostgreSQL\9.1\installer\server\startserver.vbs" postgresql-x64-9.1 Script exit code: 0 Script output: Starting postgresql-x64-9.1 Service postgresql-x64-9.1 started successfully // <==== NOT REALLY!! It stops! startserver.vbs ran to completion Script stderr: Loading additional SQL modules... Executing cscript //NoLogo "C:\Program Files\PostgreSQL\9.1\installer\server\loadmodules.vbs" "postgres" "****" "C:\Program Files\PostgreSQL\9.1" "C:\Program Files\PostgreSQL\9.1\data" 5432 Script exit code: 2 Script output: Installing the adminpack module in the postgres database... Executing 'C:\Users\HOMEUS~1\AppData\Local\Temp\rad6C20D.bat'... psql: could not connect to server: Connection refused (0x0000274D/10061) Is the server running on host "localhost" (::1) and accepting TCP/IP connections on port 5432? could not connect to server: Connection refused (0x0000274D/10061) Is the server running on host "localhost" (127.0.0.1) and accepting TCP/IP connections on port 5432? Failed to install the 'adminpack' module in the 'postgres' database loadmodules.vbs ran to completion Script stderr: Program ended with an error exit code Error running cscript //NoLogo "C:\Program Files\PostgreSQL\9.1\installer\server\loadmodules.vbs" "postgres" "****" "C:\Program Files\PostgreSQL\9.1" "C:\Program Files\PostgreSQL\9.1\data" 5432 : Program ended with an error exit code

    Read the article

  • Cannot execute cut-n-paste VBScripts

    - by IcedDante
    I have been going mad trying to figure out why my scripts weren't working, until I started copying and pasting sample source code directly from a few websites only to have it fail there as well. I am getting the following error in my VBScripts: C:\temp\vbs\script.vbs(19, 53) Microsoft VBScript compilation error: Expected statement' For a line of code that looks like this: wdoc.Application.Selection.Find.Execute Replace:=wdReplaceAll This is interfacing with Microsft Word in Office 2007 to conduct a search and replace. Index 53 point directly to the := part of the assignment. Since this type of syntax doesn't work on my machine and I am using it from several websites, I was wondering if the cscript.exe I use is out of date. Am I not calling cscript properly?

    Read the article

  • Task Scheduler not running .bat or .vbs successfully

    - by Django Reinhardt
    Hi there, got this weird problem, which will hopefully have an obvious solution for some enlightened soul: We have several daily tasks we run via a .vbs script on our server (through the Task Scheduler), and for months it has been fine, but recently we've hit a problem. The .vbs script stopped successfully executing... but oddly it worked fine when ran manually! The error given in these circumstances was always "Timeout". We thought we try a little creative thinking, and run the .vbs another way: Via a .bat file. Again we hit weird issues, but with a little more debugging information, this time around. The .bat file is nothing more than... CScript "C:\location\script.vbs" > Log.txt But the Task Scheduler fails with the following error: 0x1: An incorrect function was called or an unknown function was called. The log.txt file says: CScript Error: Initialization of the Windows Script Host failed. (Not enough storage is available to process this command. ) But get this: The .bat file executes perfectly (vbs script and all) if it's executed with a double click! There's only a problem when it's run by Task Scheduler. What the hell? We're running Windows Server 2008 R2 (x64) and yes, the Task Sheduler's results are the same whether the user is logged in or not. Also, the user that can run the scripts successfully manually, is also the same user that runs the scripts in Task Scheduler. Thanks for any help for this weird problem!

    Read the article

  • Reconfiguring, then deleting obsolete pagefile.sys from C: in one go using a batch script

    - by DanielSmedegaardBuus
    I'm trying to set up an automated script for a Windows XP installer. It's a batch script that runs on first boot after installation, and among the things I'm trying to accomplish, is removing the pagefile from C: entirely, and putting a 16-768 MB pagefile on D: instead. Here're my batch file instructions: echo === Creating new page file on D: ... cscript %windir%\system32\pagefileconfig.vbs /create /i 16 /m 768 /vo d: >nul echo. echo === Removing old page file from C: ... cscript %windir%\system32\pagefileconfig.vbs /delete /vo C: attrib -s -h c:\pagefile.sys del c:\pagefile.sys My problem is that while these are sane commands, the removal of the pagefile on C: requires me to reboot before those commands succeed.b Or, in other words — I have to first create the D: pagefile, then reboot and delete the c:\pagefile.sys file, or I'm stuck with a c:\pagefile.sys file which isn't even recognized by Windows itself (it'll just say that there's a page file on D:, and that C: has no pagefile at all). Obviously because already some pages are written to the C:\pagefile.sys file. So how would I go about accomplishing this in one go? Or, in two gos, if this is "batch scriptable" :) TIA, Daniel :) EDIT: I should probably clarify: Running those commands above are all valid, but they'll only succeed fully if I re-run the "attrib" and "del" commands at next boot. The C: pagefile is in use at the time, so I cannot delete the file it uses, and Windows itself won't remove it when I configure it to not use C: as a page file drive. Instead, it'll leave an orphaned c:\pagefile.sys file behind (which is really large). I don't necessarily need this to work in one go, registering the last two commands to run after a reboot would also be great :)

    Read the article

  • Setting "Run WWW service in IIS 5.0 isolation mode" does not persist in IIS 6

    - by Saul Dolgin
    Our IIS server was recently patched with the latest Microsoft Security Updates and since then, I am unable to enable the "Run WWW service in IIS 5.0 isolation mode" setting. This setting was enabled prior to patching and somehow changed during the updates. I have tried both using the IIS Manager console and the adsutil.vbs approach to change it. Either way, after resetting IIS for the change to take effect, when I go to verify that the isolation mode setting is enabled (true) I find that is reverts back to being disabled (false). Now... The patches have already been rolled back, however the setting still does not persist when I enable it. While I am trying to research the patches that were applied to see if there is a known issue (or perhaps a change in this setting's behavior) I was hoping someone else might have come across the same problem. Any help towards a workaround would be greatly appreciated! >cscript adsutil.vbs set W3SVC/IIs5IsolationModeEnabled TRUE IIs5IsolationModeEnabled : (BOOLEAN) True >iisreset Attempting stop... Internet services successfully stopped Attempting start... Internet services successfully restarted >cscript adsutil.vbs get W3SVC/IIs5IsolationModeEnabled IIs5IsolationModeEnabled : (BOOLEAN) False

    Read the article

  • WMI Sensors monitoring

    - by DmitrySemenov
    Monitoring tool Paessler stopped to monitor WMI Windows Sensors Paessler is Updated to version 12.4.5.3165. (10/30/2012 1:44:11 PM) Paessler windows sensors (against windows server 2008 R2 web edition) stopped to work (no changes have been made on server that we monitor) with the message Connection could not be established (80070005: Access is denied - Host: 192.168.2.10, User: Administrator, Password: **, Domain: ntlmdomain:) (code: PE015) However if I go to Virtual machine used to run Paessler and the following cscript runs successfully: strComputer = "192.168.2.10" Set objSWbemLocator = CreateObject("WbemScripting.SWbemLocator") Set objSWbemServices = objSWbemLocator.ConnectServer _ (strComputer, "root\cimv2", _ "Administrator", "pass") Set colProcessList = objSWbemServices.ExecQuery( _ "Select * From Win32_Processor") For Each objProcess in colProcessList Wscript.Echo "Process Name: " & objProcess.Name Next I'm getting output C:\>cscript test.vbs Microsoft (R) Windows Script Host Version 5.8 Copyright (C) Microsoft Corporation. All rights reserved. Process Name: Intel(R) Xeon(R) CPU X5680 @ 3.33GHz Process Name: Intel(R) Xeon(R) CPU X5680 @ 3.33GHz So WMI works a. I gave Administrator credentials for Device to monitor in Paessler setting, the same I used in the script above b. I restarted windows server (broken sensors) - but this didn't help c. I restarted Paessler probe service - no effect any ideas?

    Read the article

  • Is there Powershell way to re-apply a restored password for the IIS IUSR account?

    - by Philippe Monnet
    On one of our IIS web servers the IUSR account suddenly expired or got corrupted, I recovered the password from the IIS metabase (using Cscript adsutil.vbs get w3svc\anonymoususerpass after switching IsSecureProperty = False). I then reset the password accordingly. Now I have to re-key that password on the Directory Security tab of all virtual directories (for the anonymous account) of all web sites on that server. Is there a way to automate this using Powershell? (I have searched so far in vain)

    Read the article

  • Chef Knife-Windows

    - by Nick Zagoreos
    I'm trying to bootstrap a windows 2008 R2 Server with chef and i'm receiving this error :"CScript Error: Execution of the Windows Script Host failed. (0x800A0007)". After some research i find out that i must install the "specific_install" gem and use Knife-windows gem from git but when i'm trying to install gem with this command "gem specific_install -l https://github.com/opscode/knife-windows.git" i'm receiving the following error : "ERROR: While executing gem ... (NoMethodError) undefined method `build' for Gem::Package:Module" What am i doing wrog? Thank you in advance

    Read the article

1 2 3  | Next Page >