Search Results

Search found 46 results on 2 pages for 'enclosures'.

Page 1/2 | 1 2  | Next Page >

  • Vantec NexStar NAS Enclosures - Writing large files

    - by peter
    I have one of these 'Vantec NexStar LX - NST-475LX-BK' drive enclosures. It is a NAS device. When I write a file to the device using eSata, or a SMB share I cannot write files over 4GB. I think this is because the drive is formatted with FAT32. But when I access the device using FTP it doesn't matter. I can write files of any size. E.g. I wrote one on there last night which was 30GB. Does this make any sense? Why? I guess the most important thing for me is data integrity.

    Read the article

  • TrueCrypt Failing to Decrypt External Hard Drive after changing Enclosures

    - by Anx Ara
    I have a 4TB external hard drive that was previously encrypted using TrueCrypt. The power source on the hard drive enclosure failed, so I had to switch the hard drive itself into a new enclosure. I can no longer decrypt the hard drive using TrueCrypt, as it says my password is wrong. I am certain that I entering the correct password. Additionally, in TrueCrypt, when I try to mount the volume under "Select Device", it shows the following: Harddisk 5: 3.6TB Device\Harddisk5\Partition 1 H: 465GB Whereas before I changed the enclosure it would show: Harddisk 5: 3.6TB Device\Harddisk5\Partition 1 H: 3.6TB I am on a Windows 8 PC and using TrueCrypt 7.1a. How can I get it to decrypt properly?

    Read the article

  • Regex - Modifying strings except in specified enclosures - PHP

    - by Kovo
    I have found similar answers to my current needs on SO, however I am still trying to grasp modifying strings based on a rule, except in certain enclosures within those strings. Example of what Im trying to accomplish now: preg_replace("/\s*,\s*/", ",", $text) I found the above in many places. It will remove spaces before and after all commas in a string. That works great. However, if I want to exclude modifying commas found within " ", I am not sure how that rule has to be modified. Any help? Thanks! EDIT: I want to clarify my question: I would like all whitespace before and after the commas in the following sentence removed, except commas found in double or single quotes: a, b , c "d, e f g , " , h i j ,k lm,nop Expected result: a,b,c "d, e f g , ",h i j,k lm,nop

    Read the article

  • How to get external 2.5 inch HD enclosure get recognised

    - by fireBand
    I am completely out of ideas. I have 2.5inch HDD from my old laptop, I have tried with 2 different HDD enclosures but my desktop does not recognize it. Not even showing in the disk management or BIOS. The HDD works fine if I use in a 3.5 inch enclosure with external power. I have tried 3 different Y USB cables. I have also got a 7 port self powered 2A USB hub. I have updated my chipset drivers as well. The problem is with my desktop , the enclosures work fine with my new laptop. Anything else that I should try? Thanks in advance.

    Read the article

  • About HDD enclosure

    - by kmitnick
    hey guys, how r u doin? I have this 3.5" IDE enclosure, and it works great, I mean I love the idea of enclosures ( not the power feeding thing :), btw can't I just insert a chargable battery to feed the power when I am unable to find an electricity block), anyway my question is, when I finish the usage of the enclosure I safely remove it when using Windows or umount when working with Linux, and after that I got confused whether to turn it off or no? when I turn it off, the HDD suddenly stop spinning as if power failure not as when it was an internal and normally shuted down the pc. So is it ok to turn it off the way I've just said??? regards, ~Abed

    Read the article

  • Graciously shutdown external HDD enclosure?

    - by Jakobud
    I recently purchased a large HDD along with the following HDD enclosure: http://www.newegg.com/Product/Product.aspx?Item=N82E16817173043 It has a simple on-off switch on the back. When I want to turn this thing off, do I simply just flip the switch? I assume the switch simply kills the power to the HDD, but isn't that potentially a bad thing in the case that the HDD is still reading/writing? I used to have a Seagate external HDD and it had a button on the front that I had to hold down for a second or two before it would turn off, but it at least appeared to sort of go through a shutdown procedure where it probably would stop the HDD activity before cutting power. So with this external HDD, I'm a little bit leery about that power switch and understanding exactly what it does. Is this how all HDD enclosures are? EDIT: I'm running the drive in Ubuntu Server. So there is no 'ejecting' the drive lol

    Read the article

  • Diagnose Issues with USB External Hard Drive

    - by Chris Lieb
    I have a 1TB SATA hard drive in a third-party USB enclosure hooked up to my computer via USB. The drive has become increasingly unreliable, randomly unmounting and remounting in Windows, making strange noises on occasion, and every once in a while making lots of noise and then unmounting, only fixable by powering down the enclosure, waiting a while, then powering it back up again. I am unsure if the hard drive or the enclosure is to blame. The random unmount/remount could be the enclosure, but the strange sounds are likely related to the hard drive. Given this uncertainty, I want to figure out which of the two items needs to be replaced. However, I do not know of a way to test each item separately since I do not have an extra SATA-to-USB enclosure to test the hard drive with or an extra SATA hard drive to test the enclosure with. Does anyone know how to figure out what's to blame so that I don't have to replace both unless it is absolutely necessary.

    Read the article

  • Using an old PC case and power supply as a HDD Enclosure?

    - by mexiq
    I have 5 HDD and my computer is not handling the situation very well. hehe There are some towers that I can buy to put 4 of my drives out, but I'm thinking that I could use the power source of a failed computer I have and use it to power the 4 (or at least 3) of the drives. The data cables (SATA) will remain connected to the working computer (so no USB solution). The problem is that the power source will not work unless it is connected to the failing computer motherboard. Is there any way I could use the power source without plunging it to the old motherboard? Any "HOW-TO" links may be useful as well.

    Read the article

  • Network Server Cabinets - How does the ventilation work?

    - by Nicholas
    Recently I've been looking at a range of network server cabinets with a mesh door at the rear. At the top of the cabinet are ceiling mounted fans with dust filters attached. These fans suck air out of the cabinet - presumably to remove the hot air that has risen to the top. My question is why do these fans have dust filters? What point do they serve? If the air flow is pulled in by these fans through the mesh door, then surely they are not there to protect the hardware inside from dust? Also, there are other minor grilled gaps around the enclosure, how does this kind of ventilation design work?

    Read the article

  • Do hard drive enclosures fail/is it the HDD or enclosure?

    - by x0a
    I'm having a whole host of problems with an external hard drive that was working just fine a couple of hours ago. I've had this problem before once, and that was about 3 months ago, here's what I documented: So a couple of hours ago I turned off all my computers and shut off the power to all my devices in my room, then went and turned the power off at the main switch so I could change an outlet. A couple hours later, after I've already slowly turned everything back on, I go to my xbox to try and watch a movie and it can't seem to list any of the movies I've got. So I go to my desktop to find that my external hard drive isn't there.. even though it's on and connected. It's also stationary and hidden behind something so there's not a whole lot of tampering/physical wear to that external. I plug it into my laptop to try and see what's going on. It starts making this endless loud screeching noise. None of that clicking that's usually associated with hd damage. It's not listed in my computers, and it shows up in Disk Management as "uninitialized" asking me to choose between two different partition types. After carefully disconnecting it and connecting it back, it asks me to format it, which I cancel. I start googling about my issue, starting to accept the situation, torn as hell and helpless and just about ready to toss the thing. Suddenly the screeching stops, after almost 45 minutes of it going, and Disk Management lists the drive as "Online" and "Healthy". Explorer pops up with all my files! I'm still being really careful with it and weary and treating it as though it's in fragile shape. I've downloaded some S.M.A.R.T. software to read the values and everything is listed as "OK" . No reallocated sectors, no read errors, no seek errors. I also ran a quick self-test, which completed without error. Everything seems fine. It looks to be a perfectly healthy external hard drive. So what the hell was that about? Was it doing some sort of maintenance or self-test? How am I supposed to tell the difference? I would've undoubtedly killed the drive for sure if had it gone on a bit longer. I've got the same problem now, with one exception: it doesn't magically reappear after the screeching stops. Occasionally I manage to get some S.M.A.R.T. diagnostics information, which basically reads everything as fine. The only problem is that my HD isn't initializing (so I can't access anything in it). I'm able to successfully run a quick smart test but not an extended one (I've only tried it once but got conflicting indications as to whether it was actually making any progress or not (was stuck on Random read test). So, final question (if all else fails): Could the hard drive enclosure be failing rather than the HDD? Is this a likely possibility at all? How would I know?

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • How to find minimum cut-sets for several subgraphs of a graph of degrees 2 to 4

    - by Tore
    I have a problem, Im trying to make A* searches through a grid based game like pacman or sokoban, but i need to find "enclosures". What do i mean by enclosures? subgraphs with as few cut edges as possible given a maximum size and minimum size for number of vertices that act as soft constraints. Alternatively you could say i am looking to find bridges between subgraphs, but its generally the same problem. Given a game that looks like this, what i want to do is find enclosures so that i can properly find entrances to them and thus get a good heuristic for reaching vertices inside these enclosures. So what i want is to find these colored regions on any given map. The reason for me bothering to do this and not just staying content with the performance of a simple manhattan distance heuristic is that an enclosure heuristic can give more optimal results and i would not have to actually do the A* to get some proper distance calculations and also for later adding competitive blocking of opponents within these enclosures when playing sokoban type games. Also the enclosure heuristic can be used for a minimax approach to finding goal vertices more properly. Do you know of a good algorithm for solving this problem or have any suggestions in things i should explore?

    Read the article

  • Finding minimum cut-sets between bounded subgraphs

    - by Tore
    If a game map is partitioned into subgraphs, how to minimize edges between subgraphs? I have a problem, Im trying to make A* searches through a grid based game like pacman or sokoban, but i need to find "enclosures". What do i mean by enclosures? subgraphs with as few cut edges as possible given a maximum size and minimum size for number of vertices for each subgraph that act as a soft constraints. Alternatively you could say i am looking to find bridges between subgraphs, but its generally the same problem. Given a game that looks like this, what i want to do is find enclosures so that i can properly find entrances to them and thus get a good heuristic for reaching vertices inside these enclosures. So what i want is to find these colored regions on any given map. My Motivation The reason for me bothering to do this and not just staying content with the performance of a simple manhattan distance heuristic is that an enclosure heuristic can give more optimal results and i would not have to actually do the A* to get some proper distance calculations and also for later adding competitive blocking of opponents within these enclosures when playing sokoban type games. Also the enclosure heuristic can be used for a minimax approach to finding goal vertices more properly. A possible solution to the problem is the Kernighan-Lin algorithm: function Kernighan-Lin(G(V,E)): determine a balanced initial partition of the nodes into sets A and B do A1 := A; B1 := B compute D values for all a in A1 and b in B1 for (i := 1 to |V|/2) find a[i] from A1 and b[i] from B1, such that g[i] = D[a[i]] + D[b[i]] - 2*c[a][b] is maximal move a[i] to B1 and b[i] to A1 remove a[i] and b[i] from further consideration in this pass update D values for the elements of A1 = A1 / a[i] and B1 = B1 / b[i] end for find k which maximizes g_max, the sum of g[1],...,g[k] if (g_max > 0) then Exchange a[1],a[2],...,a[k] with b[1],b[2],...,b[k] until (g_max <= 0) return G(V,E) My problem with this algorithm is its runtime at O(n^2 * lg(n)), i am thinking of limiting the nodes in A1 and B1 to the border of each subgraph to reduce the amount of work done. I also dont understand the c[a][b] cost in the algorithm, if a and b do not have an edge between them is the cost assumed to be 0 or infinity, or should i create an edge based on some heuristic. Do you know what c[a][b] is supposed to be when there is no edge between a and b? Do you think my problem is suitable to use a multi level problem? Why or why not? Do you have a good idea for how to reduce the work done with the kernighan-lin algorithm for my problem?

    Read the article

  • 2-Bay External HDD Enclosure in JBOD mode fails to detect both drives (Linux & Windows)

    - by mgc8888
    I recently purchased a couple of USB 3.0 External HDD Enclosures to use for storage and backup; the idea was to have one act as backup to the other, with 4 x 3TB drives in total. However, the second drive in each is not accessible in either Linux nor Windows, and I could not determine the reason. 1. Situation The two enclosures are slightly different (couldn't find them in stock at the same time) yet from many little details appear to be the same Chinese base design with a tweaked outer shell. The models are: Sharkoon 2-Bay RAID Box Fantec MR-35DU3 The drives are Seagate 3TB Barracuda ST33000651AS, firmware CC44, all identical. From reading manuals and online sources, I determined that JBOD would be the optimal setup for my needs -- addressing the two drives separately in each enclosure would be important, making it easy to swap drives and mix&match them if needed; all the other modes implied the controller doing a combination of the drives. The software used was Debian GNU/Linux - testing/wheezy - kernel 2.6.39-2 and Windows 7 Ultimate. 2. Description of the problem Now, here comes the problem: every time I connect either of the enclosures to a PC using the supplied cable (tried a different one as well), only the HDD in the top bay is readable, the one below is detected yet errors out in various ways. According to the manuals, it should not happen: in JBOD, the system should be able to "see" two separate drives upon connection. This happens with both enclosures and any combination of HDDs (i.e. if I swap them, the same thing happens), so the HDDs are good and I think so are the enclosures (two different companies making similar products that failed in an identical fashion would be very unlikely). The top HDD can be used fine every time, I actually tried a speed test from Linux and got about 150MiB/s reads, so all is working as it should; the one below refuses to work every time. So the failure is consistent. To make sure this was not some obscure Linux bug, I tried the same under Windows 7, and the system also only created one drive letter for a drive of 3TB size (so it was only seeing one instead of both). Placing an older, known good, 2TB drive in the top bay made that the one recognised, so we have the same issue under Windows as well. Log entries under Linux (tested here with a 3TB and a 2TB drive so I could differentiate them; either one works in the top enclosure, in the test setup the 3TB one is on top). You can see them being detected, the top one is ok, but for the bottom one only errors: Jul 19 23:28:15 media kernel: [260150.582436] usb 6-1: New USB device found, idVendor=1ca1, idProduct=18ae Jul 19 23:28:15 media kernel: [260150.582440] usb 6-1: New USB device strings: Mfr=1, Product=2, SerialNumber=3 Jul 19 23:28:15 media kernel: [260150.582442] usb 6-1: Product: Usb Sata Bridge Jul 19 23:28:15 media kernel: [260150.582444] usb 6-1: Manufacturer: SYMWAVE Jul 19 23:28:15 media kernel: [260150.582446] usb 6-1: SerialNumber: 39584B304C4E3441 Jul 19 23:28:15 media kernel: [260150.870412] scsi11 : usb-storage 6-1:1.0 Jul 19 23:28:16 media kernel: [260151.882087] scsi 11:0:0:0: Direct-Access SYMWAVE ST33000651AS CC44 PQ: 0 ANSI: 4 Jul 19 23:28:16 media kernel: [260151.882242] scsi 11:0:0:1: Direct-Access SYMWAVE ST32000641AS CC12 PQ: 0 ANSI: 4 Jul 19 23:28:16 media kernel: [260151.882677] sd 11:0:0:0: Attached scsi generic sg2 type 0 Jul 19 23:28:16 media kernel: [260151.882774] sd 11:0:0:0: [sdb] Very big device. Trying to use READ CAPACITY(16). Jul 19 23:28:16 media kernel: [260151.882857] sd 11:0:0:1: Attached scsi generic sg3 type 0 Jul 19 23:28:16 media kernel: [260151.882893] sd 11:0:0:0: [sdb] 5860533168 512-byte logical blocks: (3.00 TB/2.72 TiB) Jul 19 23:28:16 media kernel: [260151.883085] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.883582] sd 11:0:0:0: [sdb] Write Protect is off Jul 19 23:28:16 media kernel: [260151.883961] sd 11:0:0:1: [sdc] 3907029168 512-byte logical blocks: (2.00 TB/1.81 TiB) Jul 19 23:28:16 media kernel: [260151.884145] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.884570] sd 11:0:0:1: [sdc] Write Protect is off Jul 19 23:28:16 media kernel: [260151.884855] sd 11:0:0:0: [sdb] Very big device. Trying to use READ CAPACITY(16). Jul 19 23:28:16 media kernel: [260151.885286] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.885807] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.909595] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.910159] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.910163] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.910167] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.910169] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.910172] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.910182] quiet_error: 2 callbacks suppressed Jul 19 23:28:16 media kernel: [260151.910570] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.911153] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.911156] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.911159] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.911161] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.911164] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.911385] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.911902] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.911905] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.911908] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.911910] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.911913] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.912128] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.912650] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.912653] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.912656] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.912657] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.912660] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.912876] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.913439] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.913442] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.913445] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.913446] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.913449] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 Jul 19 23:28:16 media kernel: [260151.945227] xhci_hcd 0000:03:00.0: WARN: Stalled endpoint Jul 19 23:28:16 media kernel: [260151.945863] sd 11:0:0:1: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jul 19 23:28:16 media kernel: [260151.945866] sd 11:0:0:1: [sdc] Sense Key : Illegal Request [current] Jul 19 23:28:16 media kernel: [260151.945870] Info fld=0x0 Jul 19 23:28:16 media kernel: [260151.945871] sd 11:0:0:1: [sdc] Add. Sense: Invalid field in cdb Jul 19 23:28:16 media kernel: [260151.945875] sd 11:0:0:1: [sdc] CDB: Read(10): 28 20 00 00 00 00 00 00 08 00 (...) and so on for like 10 seconds until it gives up (...) 3. Question So, my question would be: what is causing this? Am I missing something, should I configure things differently, is this a known limitation? Searching online for more information did not yield any useful results... Thank you in advance for any help!

    Read the article

  • Changing classes on multiple divs when selecting specific radio buttons

    - by Rob
    Hey everyone I got a javascript problem I can't seem to find a specific solution for on the web. What I want to be able to do is select one of the radio buttons and have that change the class of #home-right to either .rackmount or .shipping and add the class of .displaynone to the type of dimensions I don't want shown. <div id="home-right" class="rackmount"> <h4 class="helvneuebcn">Case Finder</h4> <div class="cta-options"> <input type="radio" value="Shipping and Storage" name="" checked> Shipping and Storage<br/> <input type="radio" value="Rackmount Enclosures" name=""> Rackmount Enclosures<br/> </div> <div class="shipping-dimensions displaynone"> <div class="dimensions"><input type="text" class="size"><span class="helvneuemd">H x </span></div> <div class="dimensions"><input type="text" class="size"><span class="helvneuemd">W x </span></div> <div class="dimensions"><input type="text" class="size"><span class="helvneuemd">L</span></div> </div> <div class="rackmount-dimensions"> <div class="dimensions"><input type="text" class="size"><span class="helvneuemd">U Height x </span></div> <div class="dimensions"><input type="text" class="size"><span class="helvneuemd">Rack Depth</span></div> </div> <div class="clear"></div> <input type="button" value="Submit" class="findcase"> </div>

    Read the article

  • Storage subsystem borking after server restart (all on a Parallel SCSI bus)

    - by Dat Chu
    I have a server (with a SCSI HBA) connected to two Promise VTrak M310p RAID enclosure on the same bus. Everything is working fine until I have to restart my server. Once restarted, the server can no longer communicate with the enclosures: lots of read errors and bus resets. I have to turn off both enclosure, then turn off the server, then turn on the enclosure, then turn on the server for things to work. I don't believe this is the normal behavior, what could I be missing?

    Read the article

  • Blade servers for vm?

    - by jason clark
    We're using VMware on a normal rack mounted server and considering getting another. I see these days I can pick blade enclosures and servers up for relatively low cost and see the term blade and vm mentioned quite a lot. So my question - how would a blade setup work with wmware - is the whole enclosure seen as one big machine and yhr more blades you add the more computing power/resources you get in VMware - or are the just x number of seperate servers? J

    Read the article

  • Grounded outlet on external hard drive.

    - by goathens
    Is there any value in getting an external hard drive with a grounded power supply? Would grounding the drive protect it from a static jolt from my hand when I pick it up? I've only really ever used the huge 5.25" external housings (they usually have an integrated power supply and use the standard heavy PSU cable with ground), and I need some more but noticed while shopping that the current trend is towards smaller enclosures with the external brick (and hardly ever grounded).

    Read the article

  • Forcing fputcsv to Use Enclosure For *all* Fields

    - by Alan Storm
    When I use fputcsv to write out a line to an open file handle, PHP will add an enclosing character to any column that it believes needs it, but will leave other columns without the enclosures. For example, you might end up with a line like this 11,"Bob ",Jenkins,"200 main st. USA ",etc Short of appending a bogus space to the end of every field, is there any way to force fputcsv to always enclose columns with the enclosure (defaults to a ") character?

    Read the article

  • HDD Carrier, like a soda carrier available at McDonalds?

    - by Jason Taylor
    We use external USB drives for backups, and they have to be stored offsite at the end of the week. Right now we have your standard external USB drive inside an enclosure. We were thinking about moving to a USB dock, and dock a bare HDD for backups, rather than having various sized and types of enclosures. If we were to do this, the drives need protection while being transported to/from the safety deposit box. Is there any kind of hard drive carrier that would let us slide two drives into it, and it would provide protection while the drives are carried around by non-technical people? I'm afraid such a product doesn't exist, but perhaps someone knows of something?

    Read the article

  • Change location of RSS Dynamic Desktops

    - by Andy
    I'm currently using CCleaner to take care of my computer, but I also have a dynamic desktop background provided by Bing (I'm running Windows 7 HP) - and unfortunately the two conflict. Whenever I 'clean' my computer using CCleaner it messes up my destop backgrounds as they are stored in the temporary internet files directory, and for some reason I don't appear to be able to get as far as the 'Enclosures' sub directory in order to tell CCleaner to exclude the directory (I can see it in Windows Explorer but not in CCleaner's directory browser). Therefore, I am looking for an alternative solution to this problem and wondered if I could change the directory to which the images were downloaded on the RSS feed. If anybody knows how to do this, I would be grateful if you could share or indeed, I would be equally as greatful if anyone knows any other ways of getting around CCleaner. Please note that I don't want to stop cleaning the whole of my temporary internet files though - I just don't want the wallpapers that have been downloaded to be deleted... Thanks in advance!

    Read the article

1 2  | Next Page >