  • Enterprise Process Maps: A Process Picture worth a Million Words

    - by raul.goycoolea
    p { margin-bottom: 0.08in; }h1 { margin-top: 0.33in; margin-bottom: 0in; color: rgb(54, 95, 145); page-break-inside: avoid; }h1.western { font-family: "Cambria",serif; font-size: 14pt; }h1.cjk { font-family: "DejaVu Sans"; font-size: 14pt; }h1.ctl { font-size: 14pt; } Getting Started with Business Transformations A well-known proverb states that "A picture is worth a thousand words." In relation to Business Process Management (BPM), a credible analyst might have a few questions. What if the picture was taken from some particular angle, like directly overhead? What if it was taken from only an inch away or a mile away? What if the photographer did not focus the camera correctly? Does the value of the picture depend on who is looking at it? Enterprise Process Maps are analogous in this sense of relative value. Every BPM project (holistic BPM kick-off, enterprise system implementation, Service-oriented Architecture, business process transformation, corporate performance management, etc.) should be begin with a clear understanding of the business environment, from the biggest picture representations down to the lowest level required or desired for the particular project type, scope and objectives. The Enterprise Process Map serves as an entry point for the process architecture and is defined: the single highest level of process mapping for an organization. It is constructed and evaluated during the Strategy Phase of the Business Process Management Lifecycle. (see Figure 1) Fig. 1: Business Process Management Lifecycle Many organizations view such maps as visual abstractions, constructed for the single purpose of process categorization. This, in turn, results in a lesser focus on the inherent intricacies of the Enterprise Process view, which are explored in the course of this paper. With the main focus of a large scale process documentation effort usually underlying an ERP or other system implementation, it is common for the work to be driven by the desire to "get to the details," and to the type of modeling that will derive near-term tangible results. For instance, a project in American Pharmaceutical Company X is driven by the Director of IT. With 120+ systems in place, and a lack of standardized processes across the United States, he and the VP of IT have decided to embark on a long-term ERP implementation. At the forethought of both are questions, such as: How does my application architecture map to the business? What are each application's functionalities, and where do the business processes utilize them? Where can we retire legacy systems? Well-developed BPM methodologies prescribe numerous model types to capture such information and allow for thorough analysis in these areas. Process to application maps, Event Driven Process Chains, etc. provide this level of detail and facilitate the completion of such project-specific questions. These models and such analysis are appropriately carried out at a relatively low level of process detail. (see figure 2) Fig. 2: The Level Concept, Generic Process HierarchySome of the questions remaining are ones of documentation longevity, the continuation of BPM practice in the organization, process governance and ownership, process transparency and clarity in business process objectives and strategy. The Level Concept in Brief Figure 2 shows a generic, four-level process hierarchy depicting the breakdown of a "Process Area" into progressively more detailed process classifications. The number of levels and the names of these levels are flexible, and can be fit to the standards of the organization's chosen terminology or any other chosen reference model that makes logical sense for both short and long term process description. It is at Level 1 (in this case the Process Area level), that the Enterprise Process Map is created. This map and its contained objects become the foundation for a top-down approach to subsequent mapping, object relationship development, and analysis of the organization's processes and its supporting infrastructure. Additionally, this picture serves as a communication device, at an executive level, describing the design of the business in its service to a customer. It seems, then, imperative that the process development effort, and this map, start off on the right foot. Figuring out just what that right foot is, however, is critical and trend-setting in an evolving organization. Key Considerations Enterprise Process Maps are usually not as living and breathing as other process maps. Just as it would be an extremely difficult task to change the foundation of the Sears Tower or a city plan for the entire city of Chicago, the Enterprise Process view of an organization usually remains unchanged once developed (unless, of course, an organization is at a stage where it is capable of true, high-level process innovation). Regardless, the Enterprise Process map is a key first step, and one that must be taken in a precise way. What makes this groundwork solid depends on not only the materials used to construct it (process areas), but also the layout plan and knowledge base of what will be built (the entire process architecture). It seems reasonable that care and consideration are required to create this critical high level map... but what are the important factors? Does the process modeler need to worry about how many process areas there are? About who is looking at it? Should he only use the color pink because it's his boss' favorite color? Interestingly, and perhaps surprisingly, these are all valid considerations that may just require a bit of structure. Below are Three Key Factors to consider when building an Enterprise Process Map: Company Strategic Focus Process Categorization: Customer is Core End-to-end versus Functional Processes Company Strategic Focus As mentioned above, the Enterprise Process Map is created during the Strategy Phase of the Business Process Management Lifecycle. From Oracle Business Process Management methodology for business transformation, it is apparent that business processes exist for the purpose of achieving the strategic objectives of an organization. In a prescribed, top-down approach to process development, it must be ensured that each process fulfills its objectives, and in an aggregated manner, drives fulfillment of the strategic objectives of the company, whether for particular business segments or in a broader sense. This is a crucial point, as the strategic messages of the company must therefore resound in its process maps, in particular one that spans the processes of the complete business: the Enterprise Process Map. One simple example from Company X is shown below (see figure 3). Fig. 3: Company X Enterprise Process Map In reviewing Company X's Enterprise Process Map, one can immediately begin to understand the general strategic mindset of the organization. It shows that Company X is focused on its customers, defining 10 of its process areas belonging to customer-focused categories. Additionally, the organization views these end-customer-oriented process areas as part of customer-fulfilling value chains, while support process areas do not provide as much contiguous value. However, by including both support and strategic process categorizations, it becomes apparent that all processes are considered vital to the success of the customer-oriented focus processes. Below is an example from Company Y (see figure 4). Fig. 4: Company Y Enterprise Process Map Company Y, although also a customer-oriented company, sends a differently focused message with its depiction of the Enterprise Process Map. Along the top of the map is the company's product tree, overarching the process areas, which when executed deliver the products themselves. This indicates one strategic objective of excellence in product quality. Additionally, the view represents a less linear value chain, with strong overlaps of the various process areas. Marketing and quality management are seen as a key support processes, as they span the process lifecycle. Often, companies may incorporate graphics, logos and symbols representing customers and suppliers, and other objects to truly send the strategic message to the business. Other times, Enterprise Process Maps may show high level of responsibility to organizational units, or the application types that support the process areas. It is possible that hundreds of formats and focuses can be applied to an Enterprise Process Map. What is of vital importance, however, is which formats and focuses are chosen to truly represent the direction of the company, and serve as a driver for focusing the business on the strategic objectives set forth in that right. Process Categorization: Customer is Core In the previous two examples, processes were grouped using differing categories and techniques. Company X showed one support and three customer process categorizations using encompassing chevron objects; Customer Y achieved a less distinct categorization using a gradual color scheme. Either way, and in general, modeling of the process areas becomes even more valuable and easily understood within the context of business categorization, be it strategic or otherwise. But how one categorizes their processes is typically more complex than simply choosing object shapes and colors. Previously, it was stated that the ideal is a prescribed top-down approach to developing processes, to make certain linkages all the way back up to corporate strategy. But what about external influences? What forces push and pull corporate strategy? Industry maturity, product lifecycle, market profitability, competition, etc. can all drive the critical success factors of a particular business segment, or the company as a whole, in addition to previous corporate strategy. This may seem to be turning into a discussion of theory, but that is far from the case. In fact, in years of recent study and evolution of the way businesses operate, cross-industry and across the globe, one invariable has surfaced with such strength to make it undeniable in the game plan of any strategy fit for survival. That constant is the customer. Many of a company's critical success factors, in any business segment, relate to the customer: customer retention, satisfaction, loyalty, etc. Businesses serve customers, and so do a business's processes, mapped or unmapped. The most effective way to categorize processes is in a manner that visualizes convergence to what is core for a company. It is the value chain, beginning with the customer in mind, and ending with the fulfillment of that customer, that becomes the core or the centerpiece of the Enterprise Process Map. (See figure 5) Fig. 5: Company Z Enterprise Process Map Company Z has what may be viewed as several different perspectives or "cuts" baked into their Enterprise Process Map. It has divided its processes into three main categories (top, middle, and bottom) of Management Processes, the Core Value Chain and Supporting Processes. The Core category begins with Corporate Marketing (which contains the activities of beginning to engage customers) and ends with Customer Service Management. Within the value chain, this company has divided into the focus areas of their two primary business lines, Foods and Beverages. Does this mean that areas, such as Strategy, Information Management or Project Management are not as important as those in the Core category? No! In some cases, though, depending on the organization's understanding of high-level BPM concepts, use of category names, such as "Core," "Management" or "Support," can be a touchy subject. What is important to understand, is that no matter the nomenclature chosen, the Core processes are those that drive directly to customer value, Support processes are those which make the Core processes possible to execute, and Management Processes are those which steer and influence the Core. Some common terms for these three basic categorizations are Core, Customer Fulfillment, Customer Relationship Management, Governing, Controlling, Enabling, Support, etc. End-to-end versus Functional Processes Every high and low level of process: function, task, activity, process/work step (whatever an organization calls it), should add value to the flow of business in an organization. Suppose that within the process "Deliver package," there is a documented task titled "Stop for ice cream." It doesn't take a process expert to deduce the room for improvement. Though stopping for ice cream may create gain for the one person performing it, it likely benefits neither the organization nor, more importantly, the customer. In most cases, "Stop for ice cream" wouldn't make it past the first pass of To-Be process development. What would make the cut, however, would be a flow of tasks that, each having their own value add, build up to greater and greater levels of process objective. In this case, those tasks would combine to achieve a status of "package delivered." Figure 3 shows a simple example: Just as the package can only be delivered (outcome of the process) without first being retrieved, loaded, and the travel destination reached (outcomes of the process steps), some higher level of process "Play Practical Joke" (e.g., main process or process area) cannot be completed until a package is delivered. It seems that isolated or functionally separated processes, such as "Deliver Package" (shown in Figure 6), are necessary, but are always part of a bigger value chain. Each of these individual processes must be analyzed within the context of that value chain in order to ensure successful end-to-end process performance. For example, this company's "Create Joke Package" process could be operating flawlessly and efficiently, but if a joke is never developed, it cannot be created, so the end-to-end process breaks. Fig. 6: End to End Process Construction That being recognized, it is clear that processes must be viewed as end-to-end, customer-to-customer, and in the context of company strategy. But as can also be seen from the previous example, these vital end-to-end processes cannot be built without the functionally oriented building blocks. Without one, the other cannot be had, or at least not in a complete and organized fashion. As it turns out, but not discussed in depth here, the process modeling effort, BPM organizational development, and comprehensive coverage cannot be fully realized without a semi-functional, process-oriented approach. Then, an Enterprise Process Map should be concerned with both views, the building blocks, and access points to the business-critical end-to-end processes, which they construct. Without the functional building blocks, all streams of work needed for any business transformation would be lost mess of process disorganization. End-to-end views are essential for utilization in optimization in context, understanding customer impacts, base-lining all project phases and aligning objectives. Including both views on an Enterprise Process Map allows management to understand the functional orientation of the company's processes, while still providing access to end-to-end processes, which are most valuable to them. (See figures 7 and 8). Fig. 7: Simplified Enterprise Process Map with end-to-end Access Point The above examples show two unique ways to achieve a successful Enterprise Process Map. The first example is a simple map that shows a high level set of process areas and a separate section with the end-to-end processes of concern for the organization. This particular map is filtered to show just one vital end-to-end process for a project-specific focus. Fig. 8: Detailed Enterprise Process Map showing connected Functional Processes The second example shows a more complex arrangement and categorization of functional processes (the names of each process area has been removed). The end-to-end perspective is achieved at this level through the connections (interfaces at lower levels) between these functional process areas. An important point to note is that the organization of these two views of the Enterprise Process Map is dependent, in large part, on the orientation of its audience, and the complexity of the landscape at the highest level. If both are not apparent, the Enterprise Process Map is missing an opportunity to serve as a holistic, high-level view. Conclusion In the world of BPM, and specifically regarding Enterprise Process Maps, a picture can be worth as many words as the thought and effort that is put into it. Enterprise Process Maps alone cannot change an organization, but they serve more purposes than initially meet the eye, and therefore must be designed in a way that enables a BPM mindset, business process understanding and business transformation efforts. Every Enterprise Process Map will and should be different when looking across organizations. Its design will be driven by company strategy, a level of customer focus, and functional versus end-to-end orientations. This high-level description of the considerations of the Enterprise Process Maps is not a prescriptive "how to" guide. However, a company attempting to create one may not have the practical BPM experience to truly explore its options or impacts to the coming work of business process transformation. The biggest takeaway is that process modeling, at all levels, is a science and an art, and art is open to interpretation. It is critical that the modeler of the highest level of process mapping be a cognoscente of the message he is delivering and the factors at hand. Without sufficient focus on the design of the Enterprise Process Map, an entire BPM effort may suffer. For additional information please check: Oracle Business Process Management.

    Read the article

  • How does process priority influence a process

    - by Luis Alvarado - The Wolverine
    Assuming we have read the following question: Change niceness (priority) of a running process and we know about root, non-root permissions: What actually happens when a running process (Through renice) or a new process (Through nice) gets its priority changed to a positive/negative value it previously had. Does it mean more memory is assign to it? Does more CPU power go to that particular process? Does it reduce any timing for resources for that process? What happens when the process priority change?

    Read the article

  • JSF inter-portlet communication with Oracle WebCenter

    - by Alexander Rudat
    Normal 0 21 false false false DE X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Calibri","sans-serif";}

    Read the article

  • Have local admin privileges on Windows XP, but getting "Error terminating process: Access is denied"

    - by Chris W. Rea
    On one of the Windows XP machines I use regularly, there is a process that starts up periodically. I'd like to be able to kill the process – sometimes – because it occasionally runs when I'm busy doing something machine-intensive. I've already tried dropping the process priority to "Idle" to mitigate the effects, but it isn't the CPU that's the problem. Rather, the process is very disk-intensive and no matter the process priority, it still causes significant disk thrashing when running, impacting everything else I'm doing at the time. Using Process Explorer, I can find the process, right-click, and choose Kill Process, but I always get the message "Error terminating process: Access is denied." This is not an operating system process, but third-party software. What might that process be doing to prevent itself from being terminated? How can I kill such a process? Is there a way for me to modify the process's security or access control list (ACL) somewhere, using Process Explorer or another tool, so that I can effectively kill it?

    Read the article

  • Why do we need fork to create new process

    - by user3671483
    In Unix whenever we want to create a new process, we fork the current process i.e. we create a new child process which is exactly the same as the parent process and then we do exec system call to replace the child process with a new process i.e. we replace all the data for the parent process eith that for the new process. Why do we create a copy of the parent process in the first place and why don't we create a new process directly? I am new to Unix please explain in lay-man terms.

    Read the article

  • Node.js MMO - process and/or map division

    - by Gipsy King
    I am in the phase of designing a mmo browser based game (certainly not massive, but all connected players are in the same universe), and I am struggling with finding a good solution to the problem of distributing players across processes. I'm using node.js with socket.io. I have read this helpful article, but I would like some advice since I am also concerned with different processes. Solution 1: Tie a process to a map location (like a map-cell), connect players to the process corresponding to their location. When a player performs an action, transmit it to all other players in this process. When a player moves away, he will eventually have to connect to another process (automatically). Pros: Easier to implement Cons: Must divide map into zones Player reconnection when moving into a different zone is probably annoying If one zone/process is always busy (has players in it), it doesn't really load-balance, unless I split the zone which may not be always viable There shouldn't be any visible borders Solution 1b: Same as 1, but connect processes of bordering cells, so that players on the other side of the border are visible and such. Maybe even let them interact. Solution 2: Spawn processes on demand, unrelated to a location. Have one special process to keep track of all connected player handles, their location, and the process they're connected to. Then when a player performs an action, the process finds all other nearby players (from the special player-process-location tracking node), and instructs their matching processes to relay the action. Pros: Easy load balancing: spawn more processes Avoids player reconnecting / borders between zones Cons: Harder to implement and test Additional steps of finding players, and relaying event/action to another process If the player-location-process tracking process fails, all other fail too I would like to hear if I'm missing something, or completely off track.

    Read the article

  • SOA 10g Developing a Simple Hello World Process

    - by [email protected]
    Softwares & Hardware Needed Intel Pentium D CPU 3 GHz, 2 GB RAM, Windows XP System ( Thats what i am using ) You could as well use Linux , but please choose High End RAM 10G SOA Suite from Oracle(TM) , Read Installation documents at www.Oracle.com J Developer 10.1.3.3 Official Documents at http://www.oracle.com/technology/products/ias/bpel/index.html java -version Java HotSpot(TM) Client VM (build 1.5.0_06-b05, mixed mode)BPEL Introduction - Developing a Simple Hello World Process  Synchronous BPEL Process      This Exercise focuses on developing a Synchronous Process, which mean you give input to the BPEL Process you get output immediately no waiting at all. The Objective of this exercise is to give input as name and it greets with Hello Appended by that name example, if I give input as "James" the BPEL process returns "Hello James". 1. Open the Oracle JDeveloper click on File -> New Application give the name "JamesApp" you can give your own name if it pleases you. Select the folder where you want to place the application. Click "OK" 2. Right Click on the "JamesApp" in the Application Navigator, Select New Menu. 3. Select "Projects" under "General" and "BPEL Process Project", click "OK" these steps remain same for all BPEL Projects 4. Project Setting Wizard Appears, Give the "Process Name" as "MyBPELProc" and Namespace as http://xmlns.james.com/ MyBPELProc, Select Template as "Synchronous BPEL Process click "Next" 5. Accept the input and output schema names as it is, click "Finish" 6. You would see the BPEL Process Designer, some of the folders such as Integration content and Resources are created and few more files 7. Assign Activity : Allows Assigning values to variables or copying values of one variable to another and also do some string manipulation or mathematical operations In the component palette at extreme right, select Process Activities from the drop down, and drag and drop "Assign" between "receive Input" and "replyOutput" 8. You can right click and edit the Assign activity and give any suitable name "AssignHello", 9. Select "Copy Operation" Tab create "Copy Operation" 10. In the From variables click on expression builder, select input under "input variable", Click on insert into expression bar, complete the concat syntax, Note to use "Ctrl+space bar" inside expression window to Auto Populate the expression as shown in the figure below. What we are actually doing here is concatenating the String "Hello ", with the variable value received through the variable named "input" 11. Observe that once an expression is completed the "To Variable" is assigned to a variable by name "result" 12. Finally the copy variable looks as below 13. It's the time to deploy, start the SOA Suite 14. Establish connection to the Server from JDeveloper, this can be done adding a New Application Server under Connection, give the server name, username and password and test connection. 15. Deploy the "MyBPELProc" to the "default domain" 16. http://localhost:8080/ allows connecting to SOA Suite web portal, click on "BPEL Control" , login with the username "oc4jadmin" password what ever you gave during installation 17. "MyBPELProc" is visisble under "Deployed BPEL Processes" in the "Dashboard" Tab, click on the it 18. Initiate tab open to accept input, enter data such as input is "James" click on "Post XML Button" 19. Click on Visual Flow 20. Click on receive Input , it shows "James" as input received 21. Click on reply Output, it shows "Hello James" so the BPEL process is successfully executed. 22. It may be worth seeing all the instance created everytime a BPEL process is executed by giving some inputs. Purge All button allows to delete all the unwanted previous instances of BPEL process, dont worry it wont delete the BPEL process itself :-) 23. It may also be some importance to understand the XSD File which holds input & output variable names & data types. 24. You could drag n drop variables as elements over sequence at the designer or directly edit the XML Source file. 

    Read the article

  • Start a Mapping or Process Flow from OWB Browser

    - by Dong Ruirong
    Basically, we start a Mapping or Process Flow from Oracle Warehouse Builder (OWB) Design Client. But actually we can also start a Mapping or Process Flow from OWB Browser. This paper will introduce the Start Report first and then introduce how to start/rerun a Mapping or Process Flow from OWB Browser. Start Report Start Report is used to start an execution of a Mapping or Process Flow. So there are two kinds of Start Report: Mapping Start Report (See Figure 1) and Process Flow Start Report (See Figure 2). Start Report shows the Mapping or Process Flow identification properties, including latest deployment and latest execution, lists all execution parameters for the Mapping or Process Flow, which were specified by the latest deployment, and assigns parameter default values from the latest deployment specification. You can do a couple of things from Start Report: Sort execution parameters on name, category. Table 1 lists all parameters of a Mapping. Table 2 lists all parameters of a Process Flow. Change values of any input parameter where permitted. For some parameters, selection lists are provided. For example, Mapping’s parameter Audit Level has a selection list. Reset all parameter settings to their default values. Apply basic validation to parameter values before starting an execution. Start the Mapping or Process Flow, which means it is executed immediately. Navigate to Deployment Report for latest deployment details of the Mapping or Process Flow. Navigate to Execution Job Report for latest execution of current Mapping or Process Flow Link to on-link help Warehouse Report Page, Deployment Report, Execution Report, Execution Schedule Report and Execution Summary Report. Figure 1 Mapping Start Report Table 1 Execution Parameters and default values for a Mapping Category Name Mode Input Value System Audit Level In Error Details System Bulk Size In 1000 System Commit Frequency In 1000 System EXECUTE_RESUME_TASK In FALSE System FORCE_RESUME_OPTION In FALSE System Max No of Errors In 50 System NUMBER_OF_TIMES_TO_RETRY In 2 System Operating Mode In Set Based Fail Over to Row Based System PARALLEL_LEVEL In 0 System Procedure Name In main System Purge Group In WB Figure 2 Process Flow Start Report Table 2 Execution Parameters and default values for a Process Flow Category Name Mode Input Value System EVAL_LOCATION In   System Item Key In-Out   System Item Type In PFPKG_1 Start a Mapping or Process Flow To navigate to Start Report, it’s better to login OWB Browser with Control Center option; if not, after logging in OWB Browser, go to Control Center first. Then you can follow the ways introduced in this section to navigate to Start Report. One more thing you need to pay attention to is that you are not allowed to deploy any Mappings and Process Flows from OWB Browser as it’s not supported. So it’s necessary to deploy the Mappings and Process Flows first before starting them from OWB Browser. If you have deployed a Mapping or Process Flow but have not started it, please navigate from Object Summary Report or Deployment Schedule Report to Start Report. 1. Navigating from Object Summary Report to Start Report Open the Object Summary Report to see all deployed Mappings and Process Flows. Click the Mapping Name or Process Flow Name link to see its Deployment Report. Select the Start link in the Available Reports tab for the given Mapping or Process Flow to display a Start Report for the Mapping or Process Flow. The execution parameters have the default deployment-time settings. Change any of the input parameter values as required. Click Start Execution button to execute the Mapping or Process Flow. 2. Navigating from Deployment Schedule Report to Start Report Open the Deployment Schedule Report to see deployment details of Mapping and Process Flow. Expand the project trees to find the deployed Mappings and Process Flows. Click the Mapping Name or Process Flow Name link to see its Deployment Report. Select the Start link in the Available Reports tab for the given Mapping or Process Flow to display a Start Report for the Mapping or Process Flow. The execution parameters have the default deployment-time settings. Change any of the input parameter values as required. Click Start Execution button to execute the Mapping or Process Flow. Re-run a Mapping or Process Flow If you have executed a Mapping or Process Flow, you can navigate from Object Summary Report, Deployment Schedule Report, Execution Summary Report or Execution Schedule Report to Start Report. 1. Navigating from the Execution Summary Report to Start Report Open the Execution Summary Report to see all execution jobs including Mapping jobs and Process Flow jobs. Click on the Mapping Name or Process Flow Name to see its Execution Report. Select the Start link in the Available Reports tab for the given Mapping or Process Flow to display a Start Report for the Mapping or Process Flow. The execution parameters have the default deployment-time settings. Change any of the input parameter values as required. Click Start Execution button to execute the Mapping or Process Flow. 2. Navigating from the Execution Schedule Report to Start Report Open the Execution Schedule Report to see list of all executions of Mapping and Process Flow. Click on the Mapping Name or Process Flow Name to see its Execution Report. Select the Start link in the Available Reports tab for the given Mapping or Process Flow to display a Start Report for the Mapping or Process Flow. The execution parameters have the default deployment-time settings. Change any of the input parameter values as required. Click Start Execution button to execute the Mapping or Process Flow. If the execution of a Mapping or Process Flow is successful, you will see this message from the Start Report: Start Execution request successful. (See Figure 3) Figure 3 Execution Result You can also confirm the execution of the Mapping or Process Flow by referring to Execution Report of the current Mapping or Process Flow by clicking the link in the Available Reports tab for the given Mapping or Process Flow. One new record of execution job details is added to Execution Report of the Mapping or Process Flow which shows the details of the execution such as Start Time, Elapsed Time, Status, the number of records selected, inserted, updated, deleted etc.

    Read the article

  • java Process stop entire process tree

    - by ages04
    I am using Java Runtime to run commands, including certain CVS commands. I use: process = runtime.exec ("cmd /C cvs..."); format for running the Process in Java I need to have the option of stopping it. For this I use the Java Process destroy method process.destroy(); However only the cmd is stopped not the cvs process. It continues to run as a separate process without the cmd process as the parent. There are many references to this on the internet, but I haven't found any satisfactory solution. Thanks

    Read the article

  • Is calling Process.Refresh() required for Process.HasFinished

    - by Rekreativc
    Hello I am interested if calling Process.Refresh() is mandatory when waiting for the process to terminate by checking Process.HasFinished property? I have a piece of code that works fine without the Process.Refresh() call, however I am curious weather this is a coincidence? I can see that a msdn example has the Process.Refresh() call... If its not necessary, and Process.HasExited is the only property I need, are there any advantages to making the call to Process.Refresh() ? If not, is there a reason it is in the msdn example? Thank you for your answers.

    Read the article

  • Exit code of a process terminated with Process.Kill() , in C#

    - by Emil D
    If in my C# application, I am creating a child process that can either terminate normally, or start misbehaving, in which case I terminate it with a call to Process.Kill().However, I would like to know if the process has exited normally.I know I can get the error code of a terminated process, but what would be a normal exit code and what would signify that the process was killed?

    Read the article

  • Is there a way to make sure a background process spawned by my program is killed when my process ter

    - by Davy8
    Basically the child process runs indefinitely until killed in the background, and I want to clean it up when my program terminates for any reason, i.e. via the Taskmanager. Currently I have a while (Process.GetProcessesByName("ParentProcess").Count() 0) loop and exit if the parent process isn't running, but it seems pretty brittle, and if I wanted it to work under debugger in Visual Studio I'd have to add "ParentProcess.vshost" or something. Is there any way to make sure that the child process end without requiring the child process to know about the parent process? I'd prefer a solution in managed code, but if there isn't one I can PInvoke. Edit: Passing the PID seems like a more robust solution, but for curiosity's sake, what if the child process was not my code but some exe that I have no control over? Is there a way to safeguard against possibly creating orphaned child processes?

    Read the article

  • Issues with signal handling [closed]

    - by user34790
    I am trying to actually study the signal handling behavior in multiprocess system. I have a system where there are three signal generating processes generating signals of type SIGUSR1 and SIGUSR1. I have two handler processes that handle a particular type of signal. I have another monitoring process that also receives the signals and then does its work. I have a certain issue. Whenever my signal handling processes generate a signal of a particular type, it is sent to the process group so it is received by the signal handling processes as well as the monitoring processes. Whenever the signal handlers of monitoring and signal handling processes are called, I have printed to indicate the signal handling. I was expecting a uniform series of calls for the signal handlers of the monitoring and handling processes. However, looking at the output I could see like at the beginning the monitoring and signal handling processes's signal handlers are called uniformly. However, after I could see like signal handler processes handlers being called in a burst followed by the signal handler of monitoring process being called in a burst. Here is my code and output #include <iostream> #include <sys/types.h> #include <sys/wait.h> #include <sys/time.h> #include <signal.h> #include <cstdio> #include <stdlib.h> #include <sys/ipc.h> #include <sys/shm.h> #define NUM_SENDER_PROCESSES 3 #define NUM_HANDLER_PROCESSES 4 #define NUM_SIGNAL_REPORT 10 #define MAX_SIGNAL_COUNT 100000 using namespace std; volatile int *usrsig1_handler_count; volatile int *usrsig2_handler_count; volatile int *usrsig1_sender_count; volatile int *usrsig2_sender_count; volatile int *lock_1; volatile int *lock_2; volatile int *lock_3; volatile int *lock_4; volatile int *lock_5; volatile int *lock_6; //Used only by the monitoring process volatile int monitor_count; volatile int usrsig1_monitor_count; volatile int usrsig2_monitor_count; double time_1[NUM_SIGNAL_REPORT]; double time_2[NUM_SIGNAL_REPORT]; //Used only by the main process int total_signal_count; //For shared memory int shmid; const int shareSize = sizeof(int) * (10); double timestamp() { struct timeval tp; gettimeofday(&tp, NULL); return (double)tp.tv_sec + tp.tv_usec / 1000000.; } pid_t senders[NUM_SENDER_PROCESSES]; pid_t handlers[NUM_HANDLER_PROCESSES]; pid_t reporter; void signal_catcher_1(int); void signal_catcher_2(int); void signal_catcher_int(int); void signal_catcher_monitor(int); void signal_catcher_main(int); void terminate_processes() { //Kill the child processes int status; cout << "Time up terminating the child processes" << endl; for(int i=0; i<NUM_SENDER_PROCESSES; i++) { kill(senders[i],SIGKILL); } for(int i=0; i<NUM_HANDLER_PROCESSES; i++) { kill(handlers[i],SIGKILL); } kill(reporter,SIGKILL); //Wait for the child processes to finish for(int i=0; i<NUM_SENDER_PROCESSES; i++) { waitpid(senders[i], &status, 0); } for(int i=0; i<NUM_HANDLER_PROCESSES; i++) { waitpid(handlers[i], &status, 0); } waitpid(reporter, &status, 0); } int main(int argc, char *argv[]) { if(argc != 2) { cout << "Required parameters missing. " << endl; cout << "Option 1 = 1 which means run for 30 seconds" << endl; cout << "Option 2 = 2 which means run until 100000 signals" << endl; exit(0); } int option = atoi(argv[1]); pid_t pid; if(option == 2) { if(signal(SIGUSR1, signal_catcher_main) == SIG_ERR) { perror("1"); exit(1); } if(signal(SIGUSR2, signal_catcher_main) == SIG_ERR) { perror("2"); exit(1); } } else { if(signal(SIGUSR1, SIG_IGN) == SIG_ERR) { perror("1"); exit(1); } if(signal(SIGUSR2, SIG_IGN) == SIG_ERR) { perror("2"); exit(1); } } if(signal(SIGINT, signal_catcher_int) == SIG_ERR) { perror("3"); exit(1); } /////////////////////////////////////////////////////////////////////////////////////// ////////////////////// Initializing the shared memory ///////////////////////////////// /////////////////////////////////////////////////////////////////////////////////////// cout << "Initializing the shared memory" << endl; if ((shmid=shmget(IPC_PRIVATE,shareSize,IPC_CREAT|0660))< 0) { perror("shmget fail"); exit(1); } usrsig1_handler_count = (int *) shmat(shmid, NULL, 0); usrsig2_handler_count = usrsig1_handler_count + 1; usrsig1_sender_count = usrsig2_handler_count + 1; usrsig2_sender_count = usrsig1_sender_count + 1; lock_1 = usrsig2_sender_count + 1; lock_2 = lock_1 + 1; lock_3 = lock_2 + 1; lock_4 = lock_3 + 1; lock_5 = lock_4 + 1; lock_6 = lock_5 + 1; //Initialize them to be zero *usrsig1_handler_count = 0; *usrsig2_handler_count = 0; *usrsig1_sender_count = 0; *usrsig2_sender_count = 0; *lock_1 = 0; *lock_2 = 0; *lock_3 = 0; *lock_4 = 0; *lock_5 = 0; *lock_6 = 0; cout << "End of initializing the shared memory" << endl; ///////////////////////////////////////////////////////////////////////////////////////////// /////////////////// End of initializing the shared memory /////////////////////////////////// ///////////////////////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////////////////////// /////////////////////////////Registering the signal handlers/////////////////////////////// /////////////////////////////////////////////////////////////////////////////////////////// cout << "Registering the signal handlers" << endl; for(int i=0; i<NUM_HANDLER_PROCESSES; i++) { if((pid = fork()) == 0) { if(i%2 == 0) { struct sigaction action; action.sa_handler = signal_catcher_1; sigset_t block_mask; action.sa_flags = 0; sigaction(SIGUSR1,&action,NULL); if(signal(SIGUSR2, SIG_IGN) == SIG_ERR) { perror("2"); exit(1); } } else { if(signal(SIGUSR1 ,SIG_IGN) == SIG_ERR) { perror("1"); exit(1); } struct sigaction action; action.sa_handler = signal_catcher_2; action.sa_flags = 0; sigaction(SIGUSR2,&action,NULL); } if(signal(SIGINT, SIG_DFL) == SIG_ERR) { perror("2"); exit(1); } while(true) { pause(); } exit(0); } else { //cout << "Registerd the handler " << pid << endl; handlers[i] = pid; } } cout << "End of registering the signal handlers" << endl; ///////////////////////////////////////////////////////////////////////////////////////////////////// ////////////////////////////End of registering the signal handlers ////////////////////////////////// ///////////////////////////////////////////////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////////////////////////////////////////////// ///////////////////////////Registering the monitoring process ////////////////////////////////////// //////////////////////////////////////////////////////////////////////////////////////////////////// cout << "Registering the monitoring process" << endl; if((pid = fork()) == 0) { struct sigaction action; action.sa_handler = signal_catcher_monitor; sigemptyset(&action.sa_mask); sigset_t block_mask; sigemptyset(&block_mask); sigaddset(&block_mask,SIGUSR1); sigaddset(&block_mask,SIGUSR2); action.sa_flags = 0; action.sa_mask = block_mask; sigaction(SIGUSR1,&action,NULL); sigaction(SIGUSR2,&action,NULL); if(signal(SIGINT, SIG_DFL) == SIG_ERR) { perror("2"); exit(1); } while(true) { pause(); } exit(0); } else { cout << "Monitor's pid is " << pid << endl; reporter = pid; } cout << "End of registering the monitoring process" << endl; ///////////////////////////////////////////////////////////////////////////////////////////////////// ////////////////////////End of registering the monitoring process//////////////////////////////////// ///////////////////////////////////////////////////////////////////////////////////////////////////// //Sleep to make sure that the monitor and handler processes are well initialized and ready to handle signals sleep(5); ////////////////////////////////////////////////////////////////////////////////////////////////////// //////////////////////////Registering the signal generators/////////////////////////////////////////// ///////////////////////////////////////////////////////////////////////////////////////////////////// cout << "Registering the signal generators" << endl; for(int i=0; i<NUM_SENDER_PROCESSES; i++) { if((pid = fork()) == 0) { if(signal(SIGUSR1, SIG_IGN) == SIG_ERR) { perror("1"); exit(1); } if(signal(SIGUSR2, SIG_IGN) == SIG_ERR) { perror("2"); exit(1); } if(signal(SIGINT, SIG_DFL) == SIG_ERR) { perror("2"); exit(1); } srand(i); while(true) { int signal_id = rand()%2 + 1; if(signal_id == 1) { killpg(getpgid(getpid()), SIGUSR1); while(__sync_lock_test_and_set(lock_4,1) != 0) { } (*usrsig1_sender_count)++; *lock_4 = 0; } else { killpg(getpgid(getpid()), SIGUSR2); while(__sync_lock_test_and_set(lock_5,1) != 0) { } (*usrsig2_sender_count)++; *lock_5=0; } int r = rand()%10 + 1; double s = (double)r/100; sleep(s); } exit(0); } else { //cout << "Registered the sender " << pid << endl; senders[i] = pid; } } //cout << "End of registering the signal generators" << endl; ///////////////////////////////////////////////////////////////////////////////////////////////////// //////////////////////////End of registering the signal generators/////////////////////////////////// ///////////////////////////////////////////////////////////////////////////////////////////////////// //Either sleep for 30 seconds and terminate the program or if the number of signals generated reaches 10000, terminate the program if(option = 1) { sleep(90); terminate_processes(); } else { while(true) { if(total_signal_count >= MAX_SIGNAL_COUNT) { terminate_processes(); } else { sleep(0.001); } } } } void signal_catcher_1(int the_sig) { while(__sync_lock_test_and_set(lock_1,1) != 0) { } (*usrsig1_handler_count) = (*usrsig1_handler_count) + 1; cout << "Signal Handler 1 " << *usrsig1_handler_count << endl; __sync_lock_release(lock_1); } void signal_catcher_2(int the_sig) { while(__sync_lock_test_and_set(lock_2,1) != 0) { } (*usrsig2_handler_count) = (*usrsig2_handler_count) + 1; __sync_lock_release(lock_2); } void signal_catcher_main(int the_sig) { while(__sync_lock_test_and_set(lock_6,1) != 0) { } total_signal_count++; *lock_6 = 0; } void signal_catcher_int(int the_sig) { for(int i=0; i<NUM_SENDER_PROCESSES; i++) { kill(senders[i],SIGKILL); } for(int i=0; i<NUM_HANDLER_PROCESSES; i++) { kill(handlers[i],SIGKILL); } kill(reporter,SIGKILL); exit(3); } void signal_catcher_monitor(int the_sig) { cout << "Monitoring process " << *usrsig1_handler_count << endl; } Here is the initial segment of output Monitoring process 0 Monitoring process 0 Monitoring process 0 Monitoring process 0 Signal Handler 1 1 Monitoring process 2 Signal Handler 1 2 Signal Handler 1 3 Signal Handler 1 4 Monitoring process 4 Monitoring process Signal Handler 1 6 Signal Handler 1 7 Monitoring process 7 Monitoring process 8 Monitoring process 8 Signal Handler 1 9 Monitoring process 9 Monitoring process 9 Monitoring process 10 Signal Handler 1 11 Monitoring process 11 Monitoring process 12 Signal Handler 1 13 Signal Handler 1 14 Signal Handler 1 15 Signal Handler 1 16 Signal Handler 1 17 Signal Handler 1 18 Monitoring process 19 Signal Handler 1 20 Monitoring process 20 Signal Handler 1 21 Monitoring process 21 Monitoring process 21 Monitoring process 22 Monitoring process 22 Monitoring process 23 Signal Handler 1 24 Signal Handler 1 25 Monitoring process 25 Signal Handler 1 27 Signal Handler 1 28 Signal Handler 1 29 Here is the segment when the signal handler processes signal handlers are called in a burst Signal Handler 1 456 Signal Handler 1 457 Signal Handler 1 458 Signal Handler 1 459 Signal Handler 1 460 Signal Handler 1 461 Signal Handler 1 462 Signal Handler 1 463 Signal Handler 1 464 Signal Handler 1 465 Signal Handler 1 466 Signal Handler 1 467 Signal Handler 1 468 Signal Handler 1 469 Signal Handler 1 470 Signal Handler 1 471 Signal Handler 1 472 Signal Handler 1 473 Signal Handler 1 474 Signal Handler 1 475 Signal Handler 1 476 Signal Handler 1 477 Signal Handler 1 478 Signal Handler 1 479 Signal Handler 1 480 Signal Handler 1 481 Signal Handler 1 482 Signal Handler 1 483 Signal Handler 1 484 Signal Handler 1 485 Signal Handler 1 486 Signal Handler 1 487 Signal Handler 1 488 Signal Handler 1 489 Signal Handler 1 490 Signal Handler 1 491 Signal Handler 1 492 Signal Handler 1 493 Signal Handler 1 494 Signal Handler 1 495 Signal Handler 1 496 Signal Handler 1 497 Signal Handler 1 498 Signal Handler 1 499 Signal Handler 1 500 Signal Handler 1 501 Signal Handler 1 502 Signal Handler 1 503 Signal Handler 1 504 Signal Handler 1 505 Signal Handler 1 506 Here is the segment when the monitoring processes signal handlers are called in a burst Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Monitoring process 140 Why isn't it uniform afterwards. Why are they called in a burst?

    Read the article

  • Tips/tricks/gotchas for using System.Diagnostics.Process and Process.Start

    - by puffpio
    I've used Process.Start to shell out and call 7zip to archive stuff I've also used it to call ffmpeg to compress video files. That was a while ago..but I rememeber there was some issue about the pcocess stalling if you don't read off the standardoutput/error. I don't remember everything about it. Does anyone have experience using System.Diagnostics.Process for the purposes of initiating a long running process and waiting for it to finish? Thanks

    Read the article

  • OS-independent Inter-program communication between Python and C

    - by Gyppo
    I have very little idea what I'm doing here, I've never done anything like this before, but a friend and I are writing competing chess programs and they need to be able to communicate to each other. He'll be writing mainly in C, the bulk of mine will be in Python, and I can see a few options: Alternately write to a temp file, or successive temp files. As the communication won't be in any way bulky this could work, but seems like an ugly work-around to me, the programs will have to keep checking for change/new files, it just seems ugly. Find some way of manipulating pipes i.e. mine.py| ./his . This seems like a bit of a dead end. Use sockets. But I don't know what I'd be doing, so could someone give me a pointer to some reading material? I'm not sure if there are OS-independent, language independent methods. Would there have to be some kind of supervisor server program to administrate? Use some kind of HTML protocol, which seems like overkill. I don't mind the programs having to run on the same machine. What do people recommend, and where can I start reading?

    Read the article

  • SSH main process ended

    - by Khaled
    I have a running ubuntu server 10.04.1. When I tried to login to the server via ssh, I could not. Instead, I got connection refused error. I tried to ping the machine and I got reply! So, the clear reason is that SSH daemon is stopped. After reboot, I was able to login to my server via ssh. After some time, I looked at my logs /var/log/syslog and found the following records: Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2465) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2469) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2473) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2477) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2481) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2485) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2489) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2493) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2497) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2501) terminated with status 255 Jan 16 10:57:09 myserver init: ssh respawning too fast, stopped I searched for a similar problem/solution. Some people said that this is caused by the SSH daemon trying to start before networking and they suggest to change ListenAddress in /etc/ssh/sshd_config to be 0.0.0.0. I think this is not the cause in my case, because my problem occurs after system is up and running. Any idea what is causing this? This is ubuntu server and it should be running and accessed remotely using ssh.

    Read the article

  • Book Review: Inside Windows Communicat?ion Foundation by Justin Smith

    - by Sam Abraham
    In gearing up for a new major project, I have taken it upon myself to research and review various aspects of our Microsoft stack of choice seeking new creative ways for us to leverage in our upcoming state-of-the-art solution projected to position us ahead of the competition. While I am a big supporter of search engines and online articles as a quick and usually reliable source of information, I have opted in my investigative quest to actually “hit the books”.  I have also made it a habit to provide quick reviews for material I go over hoping this can be of help to someone who may be looking for items others may have had success using for reference. I have started a few months ago by investigating better ways to implementing, profiling and troubleshooting SQL Server 2008. My reference of choice was Itzik Ben-Gan et al’s “Inside Microsoft SQL Server 2008” series. While it has been a month since my last book review, this by no means meant that I have been sitting idle. It has been pretty challenging to balance research with the continuous flow of projects and deadlines all while balancing that with my family duties which, of course, always comes first. In this post, I will be providing a quick review of my latest reading: Inside Windows Communication Foundation by Justin Smith. This book has been on my reading list for a very long time and I am proud to have finally tackled it. Justin’s book presents a great coverage of WCF internals. His simple, concise and well-worded style has simplified the relatively complex internals of WCF and made it comprehensible. Justin opted to organize the book into three parts: an introduction to WCF, coverage of the Channel Layer and a look at WCF internals at the ServiceModel layer. Part I introduced the concepts and made the case behind WCF while covering a simplified version of WCF’s message patterns, endpoints and contracts. In Part II, Justin provided a thorough coverage of the internals of Messages, Channels and Channel Managers. Part III concluded this nice reading with coverage of Bindings, Contracts, Dispatchers and Clients. While one would not likely need to extend WCF at that low level of the API, an understanding of the inner-workings of WCF is a must to avoid pitfalls mainly caused by misinformation or erroneous assumptions. Problems can quickly arise in high-traffic hosted solutions, but most can be easily avoided with some minimal time investment and education. My next goal is to pay a closer look at WCF from the programmer’s API perspective now that I have acquired a better understanding of its inner working.   Many thanks to the O’Reilly User Group Program and its support of our West Palm Beach Developers’ Group.   Stay tuned for more… All the best, --Sam

    Read the article

  • Leadership does not see value in standard process for machine configuration and new developer orientation

    - by opensourcechris
    About 3 months ago our lead web developer and designer(same person) left the company, greener pastures was the reason for leaving. Good for them I say. My problem is that his department was completely undocumented. Things have been tough since the lead left, there is a lot of knowledge both theoretical knowledge we use to quote new projects and technical/implementation knowledge of our existing products that we have lost as a result of his departure. My normal role is as a product manager (for our products themselves) and as a business analyst for some of our project based consulting work. I've taught myself to code over the past year and in an effort to continue moving forward I've taken on the task of setting my laptop up as a development machine with hopes of implementing some of the easier feature requests and fixing some of the no brainer bugs that get submitted into our ticketing system. But, no one knows how to take a fresh Windows machine and configure it to work seamlessly with our production apps. I have requested my boss, who is still in contact with the developer who left, ask them to document and create a process to onboard a new developer, software installation, required packages, process to deploy to the productions application servers, etc. None of this exists, and I'm spinning my wheels trying to get my computer working as a functional development machine. But she does not seem to understand the need for such a process to exist. Apparently the new developer who replaced the one who left has been using a machine that was pre-configured for our environment, so even the new developer could not set up a new machine if we added another developer. My question is two part: Am I wrong in assuming a process to on-board and configure a new computer to be part of our development eco-system should exist? Am I being a whinny baby and should I figure the process out and create a document on my own?

    Read the article

  • C#: Process.HasExited returns false even though the process has terminated

    - by Jeremy
    Possibly the inverse of this question: http://stackoverflow.com/questions/2519673/ I called Kill() on a process and it seems to have exited. But when I test HasExited, I get false: myProcess.Kill(); while ( !myProcess.HasExited ) { Thread.Sleep(1000); } And this continues indefinitely. Granted, I have to change this code to stop waiting eventually, but I'm curious as to why HasExited still returns false when the process seems to have dropped off the map so to speak.

    Read the article

  • WMI Remote Process Starting

    - by Goober
    Scenario I've written a WMI Wrapper that seems to be quite sufficient, however whenever I run the code to start a remote process on a server, I see the process name appear in the task manager but the process itself does not start like it should (as in, I don't see the command line log window of the process that prints out what it's doing etc.) The process I am trying to start is just a C# application executable that I have written. Below is my WMI Wrapper Code and the code I am using to start running the process. Question Is the process actually running? - Even if it is only displaying the process name in the task manager and not actually launching the application to the users window? Code To Start The Process IPHostEntry hostEntry = Dns.GetHostEntry("InsertServerName"); WMIWrapper wrapper = new WMIWrapper("Insert User Name", "Insert Password", hostEntry.HostName); List<Process> processes = wrapper.GetProcesses(); foreach (Process process in processes) { if (process.Caption.Equals("MyAppName.exe")) { Console.WriteLine(process.Caption); Console.WriteLine(process.CommandLine); int processId; wrapper.StartProcess("E:\\MyData\\Data\\MyAppName.exe", out processId); Console.WriteLine(processId.ToString()); } } Console.ReadLine(); WMI Wrapper Code using System; using System.Collections.Generic; using System.Management; using System.Runtime.InteropServices; using Common.WMI.Objects; using System.Net; namespace Common.WMIWrapper { public class WMIWrapper : IDisposable { #region Constructor /// <summary> /// Creates a new instance of the wrapper /// </summary> /// <param jobName="username"></param> /// <param jobName="password"></param> /// <param jobName="server"></param> public WMIWrapper(string server) { Initialise(server); } /// <summary> /// Creates a new instance of the wrapper /// </summary> /// <param jobName="username"></param> /// <param jobName="password"></param> /// <param jobName="server"></param> public WMIWrapper(string username, string password, string server) { Initialise(username, password, server); } #endregion #region Destructor /// <summary> /// Clean up unmanaged references /// </summary> ~WMIWrapper() { Dispose(false); } #endregion #region Initialise /// <summary> /// Initialise the WMI Connection (local machine) /// </summary> /// <param name="server"></param> private void Initialise(string server) { m_server = server; // set connection options m_connectOptions = new ConnectionOptions(); IPHostEntry host = Dns.GetHostEntry(Environment.MachineName); } /// <summary> /// Initialise the WMI connection /// </summary> /// <param jobName="username">Username to connect to server with</param> /// <param jobName="password">Password to connect to server with</param> /// <param jobName="server">Server to connect to</param> private void Initialise(string username, string password, string server) { m_server = server; // set connection options m_connectOptions = new ConnectionOptions(); IPHostEntry host = Dns.GetHostEntry(Environment.MachineName); if (host.HostName.Equals(server, StringComparison.OrdinalIgnoreCase)) return; m_connectOptions.Username = username; m_connectOptions.Password = password; m_connectOptions.Impersonation = ImpersonationLevel.Impersonate; m_connectOptions.EnablePrivileges = true; } #endregion /// <summary> /// Return a list of available wmi namespaces /// </summary> /// <returns></returns> public List<String> GetWMINamespaces() { ManagementScope wmiScope = new ManagementScope(String.Format("\\\\{0}\\root", this.Server), this.ConnectionOptions); List<String> wmiNamespaceList = new List<String>(); ManagementClass wmiNamespaces = new ManagementClass(wmiScope, new ManagementPath("__namespace"), null); ; foreach (ManagementObject ns in wmiNamespaces.GetInstances()) wmiNamespaceList.Add(ns["Name"].ToString()); return wmiNamespaceList; } /// <summary> /// Return a list of available classes in a namespace /// </summary> /// <param jobName="wmiNameSpace">Namespace to get wmi classes for</param> /// <returns>List of classes in the requested namespace</returns> public List<String> GetWMIClassList(string wmiNameSpace) { ManagementScope wmiScope = new ManagementScope(String.Format("\\\\{0}\\root\\{1}", this.Server, wmiNameSpace), this.ConnectionOptions); List<String> wmiClasses = new List<String>(); ManagementObjectSearcher wmiSearcher = new ManagementObjectSearcher(wmiScope, new WqlObjectQuery("SELECT * FROM meta_Class"), null); foreach (ManagementClass wmiClass in wmiSearcher.Get()) wmiClasses.Add(wmiClass["__CLASS"].ToString()); return wmiClasses; } /// <summary> /// Get a list of wmi properties for the specified class /// </summary> /// <param jobName="wmiNameSpace">WMI Namespace</param> /// <param jobName="wmiClass">WMI Class</param> /// <returns>List of properties for the class</returns> public List<String> GetWMIClassPropertyList(string wmiNameSpace, string wmiClass) { List<String> wmiClassProperties = new List<string>(); ManagementClass managementClass = GetWMIClass(wmiNameSpace, wmiClass); foreach (PropertyData property in managementClass.Properties) wmiClassProperties.Add(property.Name); return wmiClassProperties; } /// <summary> /// Returns a list of methods for the class /// </summary> /// <param jobName="wmiNameSpace"></param> /// <param jobName="wmiClass"></param> /// <returns></returns> public List<String> GetWMIClassMethodList(string wmiNameSpace, string wmiClass) { List<String> wmiClassMethods = new List<string>(); ManagementClass managementClass = GetWMIClass(wmiNameSpace, wmiClass); foreach (MethodData method in managementClass.Methods) wmiClassMethods.Add(method.Name); return wmiClassMethods; } /// <summary> /// Retrieve the specified management class /// </summary> /// <param jobName="wmiNameSpace">Namespace of the class</param> /// <param jobName="wmiClass">Type of the class</param> /// <returns></returns> public ManagementClass GetWMIClass(string wmiNameSpace, string wmiClass) { ManagementScope wmiScope = new ManagementScope(String.Format("\\\\{0}\\root\\{1}", this.Server, wmiNameSpace), this.ConnectionOptions); ManagementClass managementClass = null; ManagementObjectSearcher wmiSearcher = new ManagementObjectSearcher(wmiScope, new WqlObjectQuery(String.Format("SELECT * FROM meta_Class WHERE __CLASS = '{0}'", wmiClass)), null); foreach (ManagementClass wmiObject in wmiSearcher.Get()) managementClass = wmiObject; return managementClass; } /// <summary> /// Get an instance of the specficied class /// </summary> /// <param jobName="wmiNameSpace">Namespace of the classes</param> /// <param jobName="wmiClass">Type of the classes</param> /// <returns>Array of management classes</returns> public ManagementObject[] GetWMIClassObjects(string wmiNameSpace, string wmiClass) { ManagementScope wmiScope = new ManagementScope(String.Format("\\\\{0}\\root\\{1}", this.Server, wmiNameSpace), this.ConnectionOptions); List<ManagementObject> wmiClasses = new List<ManagementObject>(); ManagementObjectSearcher wmiSearcher = new ManagementObjectSearcher(wmiScope, new WqlObjectQuery(String.Format("SELECT * FROM {0}", wmiClass)), null); foreach (ManagementObject wmiObject in wmiSearcher.Get()) wmiClasses.Add(wmiObject); return wmiClasses.ToArray(); } /// <summary> /// Get a full list of services /// </summary> /// <returns></returns> public List<Service> GetServices() { return GetService(null); } /// <summary> /// Get a list of services /// </summary> /// <returns></returns> public List<Service> GetService(string name) { ManagementObject[] services = GetWMIClassObjects("CIMV2", "WIN32_Service"); List<Service> serviceList = new List<Service>(); for (int i = 0; i < services.Length; i++) { ManagementObject managementObject = services[i]; Service service = new Service(managementObject); service.Status = (string)managementObject["Status"]; service.Name = (string)managementObject["Name"]; service.DisplayName = (string)managementObject["DisplayName"]; service.PathName = (string)managementObject["PathName"]; service.ProcessId = (uint)managementObject["ProcessId"]; service.Started = (bool)managementObject["Started"]; service.StartMode = (string)managementObject["StartMode"]; service.ServiceType = (string)managementObject["ServiceType"]; service.InstallDate = (string)managementObject["InstallDate"]; service.Description = (string)managementObject["Description"]; service.Caption = (string)managementObject["Caption"]; if (String.IsNullOrEmpty(name) || name.Equals(service.Name, StringComparison.OrdinalIgnoreCase)) serviceList.Add(service); } return serviceList; } /// <summary> /// Get a list of processes /// </summary> /// <returns></returns> public List<Process> GetProcesses() { return GetProcess(null); } /// <summary> /// Get a list of processes /// </summary> /// <returns></returns> public List<Process> GetProcess(uint? processId) { ManagementObject[] processes = GetWMIClassObjects("CIMV2", "WIN32_Process"); List<Process> processList = new List<Process>(); for (int i = 0; i < processes.Length; i++) { ManagementObject managementObject = processes[i]; Process process = new Process(managementObject); process.Priority = (uint)managementObject["Priority"]; process.ProcessId = (uint)managementObject["ProcessId"]; process.Status = (string)managementObject["Status"]; DateTime createDate; if (ConvertFromWmiDate((string)managementObject["CreationDate"], out createDate)) process.CreationDate = createDate.ToString("dd-MMM-yyyy HH:mm:ss"); process.Caption = (string)managementObject["Caption"]; process.CommandLine = (string)managementObject["CommandLine"]; process.Description = (string)managementObject["Description"]; process.ExecutablePath = (string)managementObject["ExecutablePath"]; process.ExecutionState = (string)managementObject["ExecutionState"]; process.MaximumWorkingSetSize = (UInt32?)managementObject ["MaximumWorkingSetSize"]; process.MinimumWorkingSetSize = (UInt32?)managementObject["MinimumWorkingSetSize"]; process.KernelModeTime = (UInt64)managementObject["KernelModeTime"]; process.ThreadCount = (UInt32)managementObject["ThreadCount"]; process.UserModeTime = (UInt64)managementObject["UserModeTime"]; process.VirtualSize = (UInt64)managementObject["VirtualSize"]; process.WorkingSetSize = (UInt64)managementObject["WorkingSetSize"]; if (processId == null || process.ProcessId == processId.Value) processList.Add(process); } return processList; } /// <summary> /// Start the specified process /// </summary> /// <param jobName="commandLine"></param> /// <returns></returns> public bool StartProcess(string command, out int processId) { processId = int.MaxValue; ManagementClass processClass = GetWMIClass("CIMV2", "WIN32_Process"); object[] objectsIn = new object[4]; objectsIn[0] = command; processClass.InvokeMethod("Create", objectsIn); if (objectsIn[3] == null) return false; processId = int.Parse(objectsIn[3].ToString()); return true; } /// <summary> /// Schedule a process on the remote machine /// </summary> /// <param name="command"></param> /// <param name="scheduleTime"></param> /// <param name="jobName"></param> /// <returns></returns> public bool ScheduleProcess(string command, DateTime scheduleTime, out string jobName) { jobName = String.Empty; ManagementClass scheduleClass = GetWMIClass("CIMV2", "Win32_ScheduledJob"); object[] objectsIn = new object[7]; objectsIn[0] = command; objectsIn[1] = String.Format("********{0:00}{1:00}{2:00}.000000+060", scheduleTime.Hour, scheduleTime.Minute, scheduleTime.Second); objectsIn[5] = true; scheduleClass.InvokeMethod("Create", objectsIn); if (objectsIn[6] == null) return false; UInt32 scheduleid = (uint)objectsIn[6]; jobName = scheduleid.ToString(); return true; } /// <summary> /// Returns the current time on the remote server /// </summary> /// <returns></returns> public DateTime Now() { ManagementScope wmiScope = new ManagementScope(String.Format("\\\\{0}\\root\\{1}", this.Server, "CIMV2"), this.ConnectionOptions); ManagementClass managementClass = null; ManagementObjectSearcher wmiSearcher = new ManagementObjectSearcher(wmiScope, new WqlObjectQuery(String.Format("SELECT * FROM Win32_LocalTime")), null); DateTime localTime = DateTime.MinValue; foreach (ManagementObject time in wmiSearcher.Get()) { UInt32 day = (UInt32)time["Day"]; UInt32 month = (UInt32)time["Month"]; UInt32 year = (UInt32)time["Year"]; UInt32 hour = (UInt32)time["Hour"]; UInt32 minute = (UInt32)time["Minute"]; UInt32 second = (UInt32)time["Second"]; localTime = new DateTime((int)year, (int)month, (int)day, (int)hour, (int)minute, (int)second); }; return localTime; } /// <summary> /// Converts a wmi date into a proper date /// </summary> /// <param jobName="wmiDate">Wmi formatted date</param> /// <returns>Date time object</returns> private static bool ConvertFromWmiDate(string wmiDate, out DateTime properDate) { properDate = DateTime.MinValue; string properDateString; // check if string is populated if (String.IsNullOrEmpty(wmiDate)) return false; wmiDate = wmiDate.Trim().ToLower().Replace("*", "0"); string[] months = new string[] { "Jan", "Feb", "Mar", "Apr", "May", "Jun", "Jul", "Aug", "Sep", "Oct", "Nov", "Dec" }; try { properDateString = String.Format("{0}-{1}-{2} {3}:{4}:{5}.{6}", wmiDate.Substring(6, 2), months[int.Parse(wmiDate.Substring(4, 2)) - 1], wmiDate.Substring(0, 4), wmiDate.Substring(8, 2), wmiDate.Substring(10, 2), wmiDate.Substring(12, 2), wmiDate.Substring(15, 6)); } catch (InvalidCastException) { return false; } catch (ArgumentOutOfRangeException) { return false; } // try and parse the new date if (!DateTime.TryParse(properDateString, out properDate)) return false; // true if conversion successful return true; } private bool m_disposed; #region IDisposable Members /// <summary> /// Managed dispose /// </summary> public void Dispose() { Dispose(true); GC.SuppressFinalize(this); } /// <summary> /// Dispose of managed and unmanaged objects /// </summary> /// <param jobName="disposing"></param> public void Dispose(bool disposing) { if (disposing) { m_connectOptions = null; } } #endregion #region Properties private ConnectionOptions m_connectOptions; /// <summary> /// Gets or sets the management scope /// </summary> private ConnectionOptions ConnectionOptions { get { return m_connectOptions; } set { m_connectOptions = value; } } private String m_server; /// <summary> /// Gets or sets the server to connect to /// </summary> public String Server { get { return m_server; } set { m_server = value; } } #endregion } }

    Read the article

  • Java process is not terminating after starting an external process

    - by tangens
    On Windows I've started a program "async.cmd" with a ProcessBuilder like this: ProcessBuilder processBuilder = new ProcessBuilder( "async.cmd" ); processBuilder.redirectErrorStream( true ); processBuilder.start(); Then I read the output of the process in a separate thread like this: byte[] buffer = new byte[ 8192 ]; while( !interrupted() ) { int available = m_inputStream.available(); if( available == 0 ) { Thread.sleep( 100 ); continue; } int len = Math.min( buffer.length, available ); len = m_inputStream.read( buffer, 0, len ); if( len == -1 ) { throw new CX_InternalError(); } String outString = new String( buffer, 0, len ); m_output.append( outString ); } Now it happened that the content of the file "async.cmd" was this: REM start a command window start cmd /k The process that started this extenal program terminated (process.waitFor() returned the exit value). Then I sent an readerThread.interrupt() to the reader thread and the thread terminated, too. But there was still a thread running that wasn't terminating. This thread kept my java application running even if it exited its main method. With the debugger (eclipse) I wasn't able to suspend this thread. After I quit the opened command window, my java program exited, too. Question How can I quit my java program while the command window stays open?

    Read the article

  • Is there a process-oriented IDE ?

    - by Raveline
    My problem is simple : when I'm programming in an OO paradigm, I'm often having part of a main business process divided in many classes. Which means, if I want to examine the whole functional chain that leads to the output, for debugging or for optimization research, it can be a bit painful. So I was wondering : is there an IDE that let you put a "process tag" on functions coming from different objects, and give you a view of all those functions having the same tag ? edit : To give an example (that I'm making up completely, sorry if it doesn't sound very realistic). Let's say we have the following business process for a HR application : receive a holiday-request by an employee, check the validity of the request, then give an alert to his boss ("one of those lazy programmer wants another day off"); at the same time, let's say the boss will want to have a table of all employee's timetable during the time the employee wants his vacations; then handle the answer of the boss, send a nice little mail to the employee ("No way, lazy bones"). Even if we get rid of everything not purely business-related (mail sending process, db handling to get the useful info, GUI functionalities, and so on), we still have something that doesn't really fit in "one class". I'd like to have an IDE that would give me the opportunity to embrace quickly, at the very least : The function handling the validation of the request by the employee; The function preparing the "timetable" for the boss; The function handling the validation of the request by the boss; I wouldn't put all those functions in the same class (but perhaps that's my mistake ?). This is where my dreamed IDE could be helpful.

    Read the article

  • Personal Software Process (PSP1)

    - by gentoo_drummer
    I'm trying to figure out an exercise but it doesn't really makes to much sense.. I'm not asking someone to provide the solution. just to try and analyse what needs to be done in order to solve this. I'm trying to understand which PSP 1.0 1.1 process I should use. PROBE? Or something else? I would greatly appreciate some help on this one from someone that has experience with the Personal Software Process Methodology.. Here is the question. For the reference case (“code1.c”), the following s/w metrics are provided: man-hours spent in implementation phase (per-module): 2,7 mh/file man-hours spent in testing phase (per-module): 4,3 mh/file estimated number of bugs remaining (per-module): 0,3 errors/function, 4 errors/module (remaining) Based on the corresponding values provided for the reference case, each of the following tasks focus on some s/w metrics to be estimated for the test case (“code2.c”): [25 marks] (estimated) man-hours required in implementation phase (per-module) [8 marks] (estimated) man-hours required in testing phase (per-module) [8 marks] (estimated) number of bugs remaining at the end of testing phase (per-module) [9 marks] Tasks 4 through 6 should use the data provided for the reference case within the context of Personal Software Process level-1 (PSP-1), using them as a single-point historic data log. Specifically, the same s/w metrics are to be estimated for the test case (“code2.c”), using PSP as the basic estimation model. In order to perform the above listed tasks, students are advised to consider all phases of the PSP software development process, especially at levels PSP0 and PSP1. Both cases are to be treated as separate case-studies in the context of classic s/w development.

    Read the article