Search Results

Search found 59 results on 3 pages for 'mdt'.

Page 1/3 | 1 2 3  | Next Page >

  • Remove Applications page on MDT 2012 Deployment Summary

    - by Ben M.
    I am using SCCM 2012 and MDT 2012 for OSD and app deployment. Because of the nature of how some of the apps need to be detected (and which changes as apps get updated) they show up with a warning sign on the Applications tab of the Deployment Summary. There is pretty much no way to get them all green check marked (not realistically in our setup anyway) so I would like to get rid of that page so that I don't have to hear about it from my teams as they deploy. Any help would be appreciated. MDT Summary screen: Applications Installed (the tab I want to remove)

    Read the article

  • Can't connect to DeploymentShare$ from PC attempting to MDT, but can other PCs on the network

    - by Moman10
    I am in the process of setting up MDT and have run across a problem. MDT is installed on a Windows 2012 server, MDT version 6.2.5019.0. Using WDS as well. Active Directory domain, the server is up to date and on the network. I boot up the PC, it gets an address from DHCP, pulls down the LiteTouchPE_x64.wim image and goes into the MS Solution Accelerators screen, the Processing Bootstrap Settings box comes up and processes for a couple of seconds, then goes away, it sits there for another minute or so and then gives the error: A connection to the deployment share (\\Acme-MDT\DeploymentShare$) could not be made. Can not reach the DeployRoot. Possible Cause: Network Routing error or Network Configuration Error." I can then retry or cancel. I have seen this error online but so far nothing that helps fix it, but seems to be an issue with the FQDN. I verified that I am getting an IP address and that I can successfully ping the MDT server if I use the FQDN, but can not just by it's A record of Acme-MDT. I tried manually mapping the network share using net use and it works if I use the FQDN, but it fails with an error code 53, "Network path not found" if I just use the A record of Acme-MDT. Here is the net use command I'm using: net use * \\Acme-MDT\DeploymentShare$ /u:Domain\Administrator It gives the error System Error 53, Network path not found (and doesn't prompt for a password), but if I use the FQDN of \\Acme-MDT.domain.com\DeploymentShare$ it works fine to map the drive. I guess the problem is, when it tries to load the image, it is trying to start from \\Acme-MDT\DeploymentShare$ and I need it to start from \\Acme-MDT.domain.com\DeploymentShare$, but not sure how to get it to do that. I've put the fully qualified path in CustomSettings.ini and bootstrap, updated the deployment share, regenerated the boot image and replaced the boot wim in WDS. Or, if someone has an idea as to why it's acting this way and knows a way around it. The end result is what matters! :) I did verify in DNS that Acme-MDT is there, with the proper IP, and I can successfully use the net use command to map this drive from a couple other computers that are already on the network. I am assuming it has something to do with that computer not already being part of the domain, but I'm honestly at a loss as to how to fix it. Any ideas are appreciated, thanks in advance for your help!

    Read the article

  • Adding and using a Domain Admin during OSD, in MDT

    - by user195296
    So during my Windows 7 OSD. Going by Company Politics I'm suppose to A: Disabled the standardlized Administrator (Done, can do that in task sequence) B: Create a new Administrator called 'ITadmin' and set a fixed password C: Join a Domain (Done that aswell in the Task Sequence) D: Use a Domain Admin to install programs that would otherwise give problems if attempted to install through Local Admin, like Dynamics AX As written I join the computer to the Domain During the OSD, and as Result have the correct Domain Admins added as Administrators through GPO, but I don't know how to use them. I'm looking at CustomSettings.ini in the MDT pack and thinking its gotta be possible to do it from here? or from the unattend.xml in pseudo here is what I wanna Add: AddLocalAdmin: ITadmin Password: 1234 UseThisAccountToInstallOSD: Domain\Install_User Password: 1234 Any help appreciated, can't seem to google my way out of this one.

    Read the article

  • SCCM2012 R2 – How to integrate MDT with SCCM

    - by Waclaw Chrabaszcz
    Originally posted on: http://geekswithblogs.net/Wchrabaszcz/archive/2013/11/12/sccm2012-r2--how-to-integrate-mdt-with-sccm.aspxThere are two maybe not competitive but parallel products: Microsoft Deployment Toolkit and System Center Configuration manager. Few years ago I was wondering why they are separate, I why I cannot share Task Sequences between them. And how it usually happens in live, when I was focused on other technologies, MDT and SCCM became best friends. Let's integrate MDT with SCCM: If first step you need to download MDT http://www.microsoft.com/en-us/download/details.aspx?id=25175 Install MDT on your SCCM server boxaccept the EULA Join CEIP if you like  Once you completed the installation I would recommend you to complete MDT configuring before integration with the SCCM. Start the Deployment Workbenchinstall updatesyou will need to download and install WAIKcreate new deployment shareleave default values Create MDT databaseMake sure you will create separate database, DO NOT use existing SCCM DB Now we are ready to integrate MDT with SCCMthe Integration tool should discover your server automaticallyAfter reopening SCCM console in task sequences you should have new cool features: How to use them? That's another story …

    Read the article

  • WDS's MDT DeploymentShare and REMINST replicated with DFS-R does not read WIM from local WDS

    - by mbrownnyc
    I've read several guides on using DFS-R with WDS and MDT to replicate REMINST and DeploymentShare, and I have a particularly strange problem. On the receiving server, after configuring WDS and mounting the DeploymentShare into MDT's DeploymentWorkbench, I also performed the following: 1) in .\Control\Bootstrap.ini, changed DeployRoot to \%wdsserver%\DeploymentShare$ 2) Changed the UNC path at the root of the MDT Deployment Share in the DeploymentWorkbench to match that of the current server. 3) In Unattend.xml files located: .\Control**, modified the following value to match the current server: <cpi:offlineImage catelog://HOST/ I am able to boot and grab the LiteTouch PE image off the local WDS TFTP server, but the WIM files, the scripts, everything else is being pulled off the WDS server at the remote site (the original WDS server that was the source of the files within the DFS-R replicated folder). What do I do in order to solve this problem? I've grepped all the files below the DeploymentShare to look for instances of the hostname of the WDS server at the remote site (the source of the files), but I found none. Here are the guides I referred to: http://technet.microsoft.com/en-us/library/cc771324%28WS.10%29.aspx http://blogs.technet.com/b/askds/archive/2009/12/16/wds-and-dfsr-love-at-first-sync.aspx http://oasysadmin.com/2011/11/03/copying-moving-and-replicating-the-mdt-2010-deployment-share/

    Read the article

  • Moving from WDS to MDT + WDS - Prestaged Computer Name

    - by MSCF
    We previously used just WDS to deploy our images. WDS was setup to request approval for new machines. We used the "Name and Approve" option to name the machines as we added them. If it was pre-existing, it would just use the existing computer name from AD. Then in our unattend.xml file we had Computername=%MACHINENAME%. This picked up the name we gave it during approval and set the computer name accordingly. We are now implementing MDT to manage our images and drivers. But upon testing, we noticed it would assign random computer names. I went into the Unattend.xml for the deploy task sequence and added that value under Specialize amd64_Microsoft-Windows-Shell-Setup_neutral Computername=%MACHINENAME%. But when we try applying the image, it errors out at that point of the install. How can an MDT deployment be configured to leverage the pre-staged name? Some additional info: Error message during the imaging process: Windows could not parse or process the unattend answer file for pass [specialize]. The settings specified in the answer file cannot be applied. The error was detected while processing settings for component [Microsoft-Windows-Shell-Setup].? setuperr.log: 2014-07-22 14:02:13, Error [setup.exe] [Action Queue] : Unattend action failed with exit code 4 2014-07-22 14:02:13, Error [setup.exe] Execution of unattend GCs failed; hr = 0x0; pResults-hrResult = 0x8030000b

    Read the article

  • PC won't PXE boot to WDS/MDT with Dell Optiplex 755

    - by Moman10
    I am trying to set up a basic MDT solution. I have set one up in the past at a previous job and it worked flawlessly, however here I'm running into a problem and am having no luck getting around it. I've installed Windows Server 2012 and MDT 2013, along with adding on the WDS role. I haven't configured much outside of the defaults for WDS, basically just set PXE response to respond to all clients (and unchecked admin approval). This machine does not run a DHCP server. I looked on the DHCP scope of our DHCP server, it shows options 66/67 checked and the server name of the WDS server is in there as well. I didn't add this but I assume it was put on during the install process (I believe I had to manually make some adjustments at my old job for this). The PC I have is a Dell Optiplex 755. I have enabled the onbard NIC w/PXE boot option in BIOS and attempted to boot. I get a "TFTP...." error but nothing offering out a DHCP address like I'm used to. In my previous job it pretty much worked right out of the box. I've verified that PortFast is enabled on the port and I've tried a couple different PCs (but both are the same model, only model I have to work with). No matter what, I get the same error. The subnet the PC is in is a different subnet than where the WDS server is sitting, but there are IP helper statements on the switch and the PCs can get regular DHCP addresses just fine from the DHCP server, just doesn't seem to get offered out a PXE boot option. I don't know if the problem is a configuration with the server or the PC itself...but after a few days of Googling I'm running out of ideas. Does anyone have a good idea of something it may be?

    Read the article

  • MDT 2012 Image Capture

    - by floyd
    I am using MDT 2012 Update 1. Attempting to Deploy 2012 DC to a VM, run windows updates, and then sysprep/capture that image. This is the same task sequence process I have used for Windows 7 / 2008 R2 and it works fine. However, for 2012 DC it deploys the image, starts running/installing updates and then on reboot it goes to a "Choose an option" screen if I choose "Exit and continue to Windows Server 2012" it reboots and goes back to same screen. Any ideas?

    Read the article

  • Applications Deployment with MDT

    - by beakersoft
    I have added a install for Silver light to my MDT server, so it can get installed when the image gets deployed. When I boot them machines it is asking me to install the applications, how can i get it to auto install the apps without prompting. I have added this line to the rules - I thought that would but seems to make no difference. I'm sure i must have missed something somewhere? Cheers Luke

    Read the article

  • MDT Image Hierarchy

    - by Antix
    Just a quick question, I couldn't find this out by looking around and have not had the time to run a test myself: Is it possible to create image hierarchies in MDT? Take this example where we have three images. - Image 1: Base OS - Image 2: Company Wide Applications (built off Image 1) - Image 3: Specific Role Applications (built off Image 2) Now just say we change the version of an application in Image 2. The next time we build Image 3, will this take the new version of the application since it's basing its image off Image 2? Also, If we add a program to Image 1, leave Image 2 unchanged and re-build Image 3, would this include the new program? I'm trying to plan out a way of creating images such that if a change is required for an image that is on basically every machine (think, Image 1) then we only have to change it in one location. Has anyone actually done something like this and has any tips?

    Read the article

  • Modify MDT wizard to automate computer naming

    - by Jeramy
    I originally posted this question to StackOverflow, but upon further consideration it might be more appropriate here. Situation: I am imaging new systems using MDT Lite-Touch. I am trying to customize the wizard to automate the naming of new systems so that they include a prefix "AG-", a department code which is selected from a drop-down box in the wizard page (eg. "COMM"), and finally the serial number of the computer being imaged, so that my result in this case would be "AG-COMM-1234567890" Status: I have banged away at this for a while but my Google searches have not turned up answers, my trial-and-error is not producing useful error messages and I think I am missing some fundamentals of how to get variables from the wizard page into the variables used by the lite-touch wizard. Progress: I first created the HTML page which I will include below and added a script to the page to concatenate the pieces into a variable called OSDComputername which, for testing, I could output in a msgbox and get to display correctly. The problem with this is I don't know how to trigger the script then assign it to the OSDComputername variable that is used throughout the rest of the Light-Touch process. I changed the script to a function and added it to DeployWiz_Initization.vbs then used the Initialization field in WDS to call it. I'll include the function below. The problem with this is I would get "Undefined Variable" for OSDComputername and I am not sure it is pulling the data from the HTML correctly. I tried adding the scripting into the customsettings.ini file after the "OSDComputername=" This resulted in the wizard just outputting my code in text as the computer name. I am now trying adding variables to "Properties=" (eg.DepartmentName) in the customsettings.ini, pulling thier value from the HTML Form and setting that value to the variable in my function in DeployWiz_Initization.vbs and calling them after "OSDComputername=" in the fashion "OSDComputername="AG-" & %DepartmentName%" in customsettings.ini I am rebuilding right now and will see how this goes Any help would be appreciated. The HTML page: <HTML> <H1>Configure the computer name.</H1> <span style="width: 95%;"> <p>Please answer the following questions. Your answers will be used to formulate the computer's name and description.</p> <FORM NAME="TestForm"> <p>Departmental Prefix: <!-- <label class=ErrMsg id=DepartmentalPrefix_Err>* Required (MISSING)</label> --> <SELECT NAME="DepartmentalPrefix_Edit" class=WideEdit> <option value="AADC">AADC</option> <option value="AEM">AEM</option> <option value="AIP">AIP</option> <option value="COM">COM</option> <option value="DO">DO</option> <option value="DSOC">DSOC</option> <option value="EDU">EDU</option> <option value="EPE">EPE</option> <option value="ITN">ITN</option> <option value="LA">LA</option> <option value="OAP">OAP</option> <option value="SML">SML</option> </SELECT> </p> <p><span class="Larger">Client's Net<u class=larger>I</u>D:</span> <INPUT NAME="ClientNetID" TYPE="TEXT" ID="ClientNetID" SIZE="15"></p> <p>Building: <!-- <label class=ErrMsg id=Building_Err>* Required (MISSING)</label> --> <SELECT NAME="Building_Edit" class=WideEdit> <option value="Academic Surge Facility A">Academic Surge Facility A</option> <option value="Academic Surge Facility B">Academic Surge Facility B</option> <option value="Caldwell">Caldwell</option> <option value="Kennedy">Kennedy</option> <option value="Roberts">Roberts</option> <option value="Warren">Warren</option> </SELECT> </p> <p> <span class="Larger">Room <u class=larger>N</u>umber:</span> <input type=text id="RoomNumber" name=RoomNumber size=15 /> </p> </FORM> </span> </HTML> The Function: Function SetComputerName OSDComputerName = "AG-" & oEnvironment.Item("DepartmentalPrefix_Edit") ComputerDescription = oEnvironment.Item("DepartmentalPrefix_Edit") & ", " & oEnvironment.Item("ClientNetID") & ", " & oEnvironment.Item("RoomNumber") & " " & oEnvironment.Item("Building_Edit") End Function

    Read the article

  • Sysprep and Capture task sequence failing using MDT 2010

    - by Nic Young
    I have created a Windows Deployment Services server in Windows 2008 R2. When I originally set it up I was able to successfully use MDT 2010 to create my boot images as well as creating task sequences that would sysprep and capture, and deploy my custom .wim files. Everything was working perfectly. About a month later I boot up my Windows 7 x86 image and run Windows updates to keep my image up to date. I then go and run my sysprep and capture task sequence and I get the following errors: I searched online for the cause of this error message and it just seems to be a generic permission denied type of error message. I then decided to completely rebuild my VM image from scratch and try again. I am still getting the same error messages as before. The following is what I have tried troubleshooting this issue: Troubleshooting: I have ensured that that UAC and the firewall is turned completely off when trying to capture the image. I have tried recreating the task sequence and making sure that the deployment share is updated. I have ensured that the local Administrator account is enabled and has the same password as specified in the task sequence. I have tried joining the computer to the domain and running the task sequence and I get a different error: I have attempted to run the script from the command prompt with "Run as Administrator" and I still receive the same errors above. For testing purposes I have ensured that Everyone has read/write access to my deployment share. I have spent days on trying to resolve this to no avail. Any ideas? EDIT: Below is the log info from C:\Windows\Deploymentlogs\BDD.log as requested. <![LOG[LTI Windows PE applied successfully]LOG]!><time="11:48:34.000+000" date="07-25-2012" component="LTIApply" context="" type="1" thread="" file="LTIApply"> <![LOG[LTIApply processing completed successfully.]LOG]!><time="11:48:34.000+000" date="07-25-2012" component="LTIApply" context="" type="1" thread="" file="LTIApply"> <![LOG[Microsoft Deployment Toolkit version: 6.0.2223.0]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="ZTIDrivers" context="" type="1" thread="" file="ZTIDrivers"> <![LOG[The task sequencer log is located at C:\Users\nicy\AppData\Local\Temp\SMSTSLog\SMSTS.LOG. For task sequence failures, please consult this log.]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="ZTIDrivers" context="" type="1" thread="" file="ZTIDrivers"> <![LOG[Processing drivers for an X86 operating system.]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="ZTIDrivers" context="" type="1" thread="" file="ZTIDrivers"> <![LOG[TargetOS is the current SystemDrive]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="ZTIDrivers" context="" type="1" thread="" file="ZTIDrivers"> <![LOG[Property DriverCleanup is now = DONE]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="ZTIDrivers" context="" type="1" thread="" file="ZTIDrivers"> <![LOG[Compare Image processor Type with Original [X86] = [X86].]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="ZTIDrivers" context="" type="1" thread="" file="ZTIDrivers"> <![LOG[Prepare machine for Sysprep.]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="ZTIDrivers" context="" type="1" thread="" file="ZTIDrivers"> <![LOG[No driver actions can be taken for OS Images installed from *.wim files.]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="ZTIDrivers" context="" type="1" thread="" file="ZTIDrivers"> <![LOG[ZTIDrivers processing completed successfully.]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="ZTIDrivers" context="" type="1" thread="" file="ZTIDrivers"> <![LOG[Command completed, return code = -2147467259]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> <![LOG[Litetouch deployment failed, Return Code = -2147467259 0x80004005]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="LiteTouch" context="" type="3" thread="" file="LiteTouch"> <![LOG[For more information, consult the task sequencer log ...\SMSTS.LOG.]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> <![LOG[Property RetVal is now = -2147467259]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> <![LOG[Unable to copy log to the network as no SLShare value was specified.]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> <![LOG[CleanStartItems Complete]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> <![LOG[Unregistering TSCore.dll.]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> <![LOG[About to run command: wscript.exe "\\server\deploymentshare$\Scripts\LTICleanup.wsf"]LOG]!><time="11:48:35.000+000" date="07-25-2012" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> <![LOG[Microsoft Deployment Toolkit version: 6.0.2223.0]LOG]!><time="11:48:36.000+000" date="07-25-2012" component="LTICleanup" context="" type="1" thread="" file="LTICleanup"> <![LOG[Removing AutoAdminLogon registry entries]LOG]!><time="11:48:36.000+000" date="07-25-2012" component="LTICleanup" context="" type="1" thread="" file="LTICleanup"> <![LOG[VSSMaxSize not specified using 5% of volume.]LOG]!><time="11:48:36.000+000" date="07-25-2012" component="LTICleanup" context="" type="1" thread="" file="LTICleanup"> <![LOG[Logs contained 7 errors and 0 warnings.]LOG]!><time="11:48:36.000+000" date="07-25-2012" component="LTICleanup" context="" type="1" thread="" file="LTICleanup"> <![LOG[Stripping BDD commands from unattend.xml template.]LOG]!><time="11:48:36.000+000" date="07-25-2012" component="LTICleanup" context="" type="1" thread="" file="LTICleanup"> <![LOG[Modified unattend.xml saved to C:\windows\panther\unattend.xml]LOG]!><time="11:48:36.000+000" date="07-25-2012" component="LTICleanup" context="" type="1" thread="" file="LTICleanup"> <![LOG[Checking mapped network drive.]LOG]!><time="11:48:36.000+000" date="07-25-2012" component="LTICleanup" context="" type="1" thread="" file="LTICleanup"> <![LOG[testing drive Z: mapped to \\server\deploymentshare$]LOG]!><time="11:48:36.000+000" date="07-25-2012" component="LTICleanup" context="" type="1" thread="" file="LTICleanup"> <![LOG[Disconnecting drive Z: mapped to \\server\deploymentshare$]LOG]!><time="11:48:36.000+000" date="07-25-2012" component="LTICleanup" context="" type="1" thread="" file="LTICleanup"> <![LOG[Cleaning up C:\MININT directory.]LOG]!><time="11:48:36.000+000" date="07-25-2012" component="LTICleanup" context="" type="1" thread="" file="LTICleanup"> <![LOG[Cleaning up TOOLS, SCRIPTS, and PACKAGES directories.]LOG]!><time="11:48:36.000+000" date="07-25-2012" component="LTICleanup" context="" type="1" thread="" file="LTICleanup">

    Read the article

  • MDT 2010 Litetouch.vbs Fails to Launch

    - by Mitch
    I have the custom image captured. Import the image and files. Prepare the customsettings.ini and the boot.ini to minimize the questions the deployment team will need to answer. Everything works like a charm on virtual machines but when I map to the scripts folder on the deployment share and double-click litetouch.vbs it creates the c:\minint folder, subfolders, and a couple of log files then nothing. Here's what the log files look like: <![LOG[Property LogPath is now = C:\MININT\SMSOSD\OSDLOGS]LOG]!><time="15:54:28.000+000" date="03-08-2011" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> <![LOG[Property CleanStart is now = ]LOG]!><time="15:54:28.000+000" date="03-08-2011" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> <![LOG[Microsoft Deployment Toolkit version: 5.1.1642.01]LOG]!><time="15:54:28.000+000" date="03-08-2011" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> <![LOG[Property Debug is now = FALSE]LOG]!><time="15:54:28.000+000" date="03-08-2011" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> <![LOG[GetAllFixedDrives(False)]LOG]!><time="15:54:28.000+000" date="03-08-2011" component="LiteTouch" context="" type="1" thread="" file="LiteTouch"> Anyone encounter this before or know what might be happening/not happening and can direct me in the right way? I've only found a couple of other references to this anywhere and they had no solution/cause listed either. I'm stumped.

    Read the article

  • Deploying Office 2010 with MDT 2012 - Multiple Customisaton Files?

    - by Tony Blunt
    I'm in the process of setting up a deployment share for Windows 7 and Office 2010 Pro Plus, using MDT 2012. My question involves the customisation of the Office 2010 install. I've imported Office into MDT and I've successfully created a custom MSP file to tailor the settings to our business. However, I need to have a number of different customisations for different groups of users. For instance, our laptop users need Outlook Anywhere configured whereas desktop users do not. Basically - what's the best way of doing this? Do I have to import Office into MDT more than once, each instance using a different MSP, then have the task sequence select the appropriate instance? It's just that this method seems extremely wasteful so I'm thinking that there's a more intelligent way to do it? Or am I coming at this from the wrong direction? Should I be looking at Group Policy to tweak the Outlook settings in this instance? I'm just aware that there are certain things that OCT can do that group policy cannot, so I would have thought that there must be something I can do in MDT. I'm new to MDT so any pointers will be apprectiated. Thanks in advance.

    Read the article

  • How does MDT resolve settings specified in multiple machine roles?

    - by niteice
    I have a number of machines in MDT that belong to multiple roles. Nothing fancy there. However, in role A (which applies to most machines) the MachineObjectOU is specified, and in role B (which only applies to certain machines) a different MachineObjectOU is specified because those machines need to appear somewhere different in the directory. How do I guarantee that MDT will read settings from role B? Is it the order of roles in the list in the machine properties window?

    Read the article

  • How best to set up MDT developement and production?

    - by nray
    What's your MDT 2010 test and prod setup? What do you consider best practice? Is it best to use linked deployment shares, and replicate from development to production when testing is complete? What about backing out, if something breaks? Does anyone run MDT shares in DFS, or is there no support in the WinPE boot image for DFS shares? Or what about moving the production share name from one deployment share to another, as you add and test more OS versions, drivers, attributes, etc?

    Read the article

  • Will USMT 4.0 in MDT 2010 Move/Migrate the .NK2 File for Outlook?

    - by Mitch
    We're about to begin a refresh project for about 100 XP Pro laptops and have a concern with regards to the .NK2 file which holds cached email addresses(?). If possible we'd like to have USMT move/migrate this but I can't find anything that confirms that this happens automatically or has been done before. I see lots of manual processes but at this point I'm not sure that we can use that. Has anyone done this or seen this done? Perhaps you can point me to a resource that can give me an idea how its done? Any information would be appreciated. USMT seems to get a lot of the details but missing this part seems odd. Thanks in advance for any responses.

    Read the article

  • Error when trying to deploy Windows XP SP3 with WDS

    - by Nic Young
    I have created a WDS server running Windows Server 2008 R2. I have built my custom images of Windows 7 using WAIK and MDT 2010 that are installed on the server. I used this guide to help me through the process. The Windows 7 images that I have created capture and deploy properly. I am attempting to follow the same steps from the guide I linked to capture and deploy a Windows XP SP3 image. I am able to sysprep and capture the reference machine with no errors. I am then able to import the custom .wim that I just captured in to MDT 2010 with no issues either. However when I try to deploy this image to a test virtual machine I get the following error: Deployment Error: I have made sure that the .iso that I am importing the source files from originally to create the sysprep and capture sequence is indeed a Windows XP SP3 iso. When I first select a PE boot environment before I deploy I select the x86 PE boot image that I created originally when making this for my Windows 7 deployments. Could this be the issue? If so how do I make a boot image specific for Windows XP SP3 deployments? I have Googled around for this error and some places point to the deployment image not being able to find setup.exe and other important system files for installing the operating system. If so, how do I add these to the image? Any ideas?

    Read the article

  • Unattended Windows XP Install Stops at Deleting Previous Installation

    - by maik
    I'm not sure if I'm just not asking Google properly or what, but I can't come up with a good answer to this problem. We have MDT 2010 setup and have a Task Sequence for refreshing Windows XP machines. It doesn't seem to happen all the time, but a lot of the time when we start a refresh it goes through the normal motions and when it gets into the first part of Windows XP setup (the blue screen) it stops, telling me a Windows installation already exists at that location and I can press L to continue, erasing everything and using that folder. I've poured over the unattend file and can't find an option that will just delete the old files and keep going, so I'm at a loss. Any ideas?

    Read the article

  • Driver problems with rerunning WIM capture

    - by Tim Brigham
    How do I handle driver problems associated with creating a new WIM file using a previously created image as a base? I am using a custom MDT image which installs Windows 7, Office 2010, etc which was created from a previously deployed base image of Windows 7 + SP 1 + updates. When the driver injection is enabled I receive a group of messages (collected from different logs, screens, etc). If I turn the preinstall driver injection off things work as expected. If I leave it on I receive the following messages. windows cannot install required files 0x80004005 8004004 non zero return code ltiapply rc=31 Unhandled error returned by LTIApply: a device attached to the system is not functioning. (-2147024865 0x8007001F)

    Read the article

  • Windows 7 AIK help

    - by microchasm
    I've just got in a few Windows 7 (64, Windows 7 Professional) machines, and I'm trying to get the AIK 2010 working. I've set up one of the machines, and installed AIK and MDT on it. I've followed the directions at http://technet.microsoft.com/en-us/library/dd349348%28WS.10%29.aspx about 3 times now, and also tried the built-in .chm help files that came with AIK. In AIK I grab the install.wim image off the OEM cd, at which point it asks me which version (I select Professional). I follow the rest of the instructions creating a new Autounattend answer file, and fill in the various bits and pieces according the the step-by-step guides. I verify the Answer file (No warnings or errors), save it, and copy it onto a USB drive. I go to another machine, insert it's OEM Win7 Disk, and power on. I've set BIOS to boot from CD, so it goes directly into the installation. Once The files are loaded, and Setup starts, it immediately asks which version to install (Home basic, Home Premium, Professiona, Ultimate). Ugh, I thought it was supposed to be an automated install, and that selecting the Version when opening the .wim file would answer this question. I looked for an option to set which version to be installed on the net, in the help, and in AIK itself; to no avail. Anyway, just for laughs I select Professional,and hit continue. It copies files for about 10 seconds, then fails with the following error: "Setup was unable to create a new system partition or locate an existing system partition. See the setup log files for more information. [OK]". Clicking OK reboots the box, and obviously there are no log files because the OS isn't installed. It is a Dell Optiplex 380 , Intel Core Duo 2.93 GHzl 4 GB RAM, 64 Bit. Any help would be REALLY appreciated.

    Read the article

  • Microsoft deployment toolkit 2010 failure message

    - by elhombre
    Hi all I am having a problem with the deployment of Windows 7 from a server with Microsoft Toolkit 2010. When deployment has finished I get a Windows error report which shows following message. FAILURE (Er): 70: CreateObject(Microsoft.BDD.Utility) - Permission denied Litetouch deployment failed, Return Code = - 2147023589 0x8007051B I don't get it what Microsoft.BDD.Utility is exactly and when this utility is used (Tasksequence?) ? Can anyone help me on this problem?

    Read the article

  • What is in scala-android.jar?

    - by synic
    I've been trying to experiment with developing Android applications with Scala. I've gotten to the point where I can get the app to compile, but there are no helper functions for things like: button.setOnClickListener( () => { text.setText("test") }) (I'm talking about the closure there) I see lots of references to scala-android.jar, and have this file in my project, but I'm not sure what it does, or how to use it. I get the feeling it has these helper conversion functions, but I'm not sure. Running jar -tvf scala-android.jar on the file gives me this: 401 Sun Jun 06 10:06:02 MDT 2010 scala/Function0$class.class 431 Sun Jun 06 10:06:02 MDT 2010 scala/Function0.class 572 Sun Jun 06 10:06:02 MDT 2010 scala/Function1.class 282 Sun Jun 06 10:06:02 MDT 2010 scala/ScalaObject$class.class 271 Sun Jun 06 10:06:02 MDT 2010 scala/ScalaObject.class 458 Sun Jun 06 10:06:02 MDT 2010 scala/runtime/BoxedUnit.class If this isn't what I'm looking for, is there a simple library that'll do conversions for this kind of stuff?

    Read the article

  • Lustre - issues with simple setup

    - by ethrbunny
    Issue: I'm trying to assess the (possible) use of Lustre for our group. To this end I've been trying to create a simple system to explore the nuances. I can't seem to get past the 'llmount.sh' test with any degree of success. What I've done: Each system (throwaway PCs with 70Gb HD, 2Gb RAM) is formatted with CentOS 6.2. I then update everything and install the Lustre kernel from downloads.whamcloud.com and add on the various (appropriate) lustre and e2fs RPM files. Systems are rebooted and tested with 'llmount.sh' (and then cleared with 'llmountcleanup.sh'). All is well to this point. First I create an MDS/MDT system via: /usr/sbin/mkfs.lustre --mgs --mdt --fsname=lustre --device-size=200000 --param sys.timeout=20 --mountfsoptions=errors=remount-ro,user_xattr,acl --param lov.stripesize=1048576 --param lov.stripecount=0 --param mdt.identity_upcall=/usr/sbin/l_getidentity --backfstype ldiskfs --reformat /tmp/lustre-mdt1 and then mkdir -p /mnt/mds1 mount -t lustre -o loop,user_xattr,acl /tmp/lustre-mdt1 /mnt/mds1 Next I take 3 systems and create a 2Gb loop mount via: /usr/sbin/mkfs.lustre --ost --fsname=lustre --device-size=200000 --param sys.timeout=20 --mgsnode=lustre_MDS0@tcp --backfstype ldiskfs --reformat /tmp/lustre-ost1 mkdir -p /mnt/ost1 mount -t lustre -o loop /tmp/lustre-ost1 /mnt/ost1 The logs on the MDT box show the OSS boxes connecting up. All appears ok. Last I create a client and attach to the MDT box: mkdir -p /mnt/lustre mount -t lustre -o user_xattr,acl,flock luster_MDS0@tcp:/lustre /mnt/lustre Again, the log on the MDT box shows the client connection. Appears to be successful. Here's where the issues (appear to) start. If I do a 'df -h' on the client it hangs after showing the system drives. If I attempt to create files (via 'dd') on the lustre mount the session hangs and the job can't be killed. Rebooting the client is the only solution. If I do a 'lctl dl' from the client it shows that only 2/3 OST boxes are found and 'UP'. [root@lfsclient0 etc]# lctl dl 0 UP mgc MGC10.127.24.42@tcp 282d249f-fcb2-b90f-8c4e-2f1415485410 5 1 UP lov lustre-clilov-ffff880037e4d400 00fc176e-3156-0490-44e1-da911be9f9df 4 2 UP lmv lustre-clilmv-ffff880037e4d400 00fc176e-3156-0490-44e1-da911be9f9df 4 3 UP mdc lustre-MDT0000-mdc-ffff880037e4d400 00fc176e-3156-0490-44e1-da911be9f9df 5 4 UP osc lustre-OST0000-osc-ffff880037e4d400 00fc176e-3156-0490-44e1-da911be9f9df 5 5 UP osc lustre-OST0003-osc-ffff880037e4d400 00fc176e-3156-0490-44e1-da911be9f9df 5 Doing a 'lfs df' from the client shows: [root@lfsclient0 etc]# lfs df UUID 1K-blocks Used Available Use% Mounted on lustre-MDT0000_UUID 149944 16900 123044 12% /mnt/lustre[MDT:0] OST0000 : inactive device OST0001 : Resource temporarily unavailable OST0002 : Resource temporarily unavailable lustre-OST0003_UUID 187464 24764 152636 14% /mnt/lustre[OST:3] filesystem summary: 187464 24764 152636 14% /mnt/lustre Given that each OSS box has a 2Gb (loop) mount I would expect to see this reflected in available size. There are no errors on the MDS/MDT box to indicate that multiple OSS/OST boxes have been lost. EDIT: each system has all other systems defined in /etc/hosts and entries in iptables to provide access. SO: I'm clearly making several mistakes. Any pointers as to where to start correcting them?

    Read the article

  • Troubleshooting Mid 2007 iMac RAM upgrade

    - by MDT
    I am trying to install new RAM in my friends iMac, something I have done several times before. We unplugged the computer before performing the upgrade, used anti static wrist bands, and yes the memory is compatible and inserted correctly. The stock RAM was Hynix 1gb pc2-5300s-555-12 and the memory we are replacing it with is 2x2gb Centon CMP800SO2048.01. Now I know this model number suggests that the ram is 800MHz and the iMac is only 667MHz but it clearly states on the box that this RAM is PC2-5300 667MHz compatible. The problem is, that when I install the new RAM I get little response from the computer. I hear the hard drive and disk drive start to initialize, but then they just stop and the screen remains black. I have tried every variation of the new RAM and the old RAM in both slots and even tried the same RAM from my old iMac and I just can't get it to boot. Has anyone ever had a problem like this? Thank you in advance for any and all input on thus issue!

    Read the article

1 2 3  | Next Page >