Search Results

Search found 968 results on 39 pages for 'notify'.

Page 1/39 | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Expiry time in notify-send notifications

    - by gsingh2011
    On my HP computer running Ubuntu 12.04, the brightness and volume increments were much higher than I wanted. On top of that, the notification for the volume was just plain wrong (0% sound did not correspond to 0 on the progress bar). So I decided to override these options with my own commands. I used CompizConfig Settings Manager to add custom commands to the brightness and volume keys (this couldn't be done in the regular settings because these keys were handled by the BIOS, unlike normal function keys). I used xbacklight to control the brightness and amixer to control the volume. The problem is that the nice notify-send notifications don't show up when I manually set the brightness/volume, so now I have to do that myself too. However, there are two problems with notify-send: The expire time option doesn't work You have to wait until a notification is finished before the next one comes up Before I overrided the brightness/volume keys, the system was able to send notifications without these two restrictions. Notifications disappeared within 3 seconds (instead of the default 10), and if I double tapped the volume or brightness button, the progress bar would immediately change to the new brightness (instead of showing the old progress bar for 10 seconds and then showing the new one). Since the system was able to do it, I was wondering how I can achieve the same type of notifications?

    Read the article

  • How to force a new Notification in notify-osd to show up without waiting for the earlier one to exit?

    - by Nirmik
    I have made a script(and a .desktop shortcut leading to this script) for starting and stoping xampp... It checks the status of xampp and accordingly either starts or stops xampp. Now i have assigned a notification as soon as the script is started to display "Starting xampp..." or "Stopping xampp..." and then when xampp is started or stopped,it displays "Xampp started..." or "Xampp stopped..." I've used notify-send to show notification as seen in the script below Now the thing is that here,the second notification waits for the 1st one to disappear and then pops up even if xampp has started/stopped. I want the new notification to appear immediately by forcing the earlier one to exit before the completion of its life-cycle. This can be seen to take plce when you activate/deactivate wireless/networking immediately... For example the "Wireless enabled" comes up on selecting enable wireless and if you immediately select disable wireless,the "Wireless disabled" notification comes up without waiting for "Wireless enabled" notification to complete its life-cycle. So how do i achieve this? #!/bin/sh SERVICE='proftpd' if ps ax | grep -v grep | grep $SERVICE /dev/null then notify-send -i /opt/lampp/htdocs/xampp/img/logo-small.gif "Stopping XAMPP..." && gksudo /opt/lampp/lampp stop && notify-send -i /opt/lampp/htdocs/xampp/img/logo- small.gif "XAMPP Stoped." else notify-send -i /opt/lampp/htdocs/xampp/img/logo-small.gif "Starting XAMPP..." && gksudo /opt/lampp/lampp start && notify-send -i /opt/lampp/htdocs/xampp/img/logo-small.gif "XAMPP Started." fi On the man page for notify-send I found --urgency=LEVEL or -u where levels are low, normal, critical. Is this of any use? making it critical? Also I tried it with the command- notify-send -u=critical"Testing" but that dint work...it gives the error- Unknown urgency criticalTesting specified. Known urgency levels: low, normal, critical. or if I give the command notify-send -u=LOW"Testing" it gives me error missing argument to -u Any relation??

    Read the article

  • Notify-osd notifications appear unthemed in top-left corner (ubuntu 13.10)

    - by Wehlutyk
    Problem I recently upgraded from 13.04 to 13.10, and suddenly notification bubbles don't appear themed as usual in the upper right corner, but they appear as white text on blue background in the upper-left corner. It looks like this: Unsuccesful attempts to fix it I tried reinstalling unity, notify-osd, ubuntu-desktop removed notification-daemon which was installed, none of that fixes it. In fact running ps aux | grep notify-osd shows that notify-osd isn't even running. But when I try to start it manually by running /usr/lib/x86_64-linux-gnu/notify-osd I get: ** (notify-osd:4618): WARNING **: Another instance has already registered org.freedesktop.Notifications ** (notify-osd:4618): WARNING **: Could not register instance If I understand well, the instance is registered by the /usr/share/dbus-1/services/org.freedesktop.Notifications.service file, which right now contains: [D-BUS Service] Name=org.freedesktop.Notifications Exec=/usr/lib/x86_64-linux-gnu/notify-osd Renaming or deleting that file (and rebooting) has no effect whatsoever (and it is not recreated automatically). This is not a duplicate of No notifications from notify-osd on 13.10 (and by the way I purged gnome-flashback-session along with notification-daemon) Question(s) How can I debug this? How can I get notifications to come back to normal? If additional debug information is needed, I'll be happy to add it (just that I can't find any more).

    Read the article

  • notify-send ignores timeout?

    - by Hooked
    Maybe I'm doing something wrong, but shouldn't the commands (run separately) notify-send -t 1 "test" notify-send -t 1000 "test" notify-send -t 10000 "test" Have different timeouts? The first being nearly instantaneous, the second one taking 1 sec and the third 100 seconds. In all cases it seems to take about six seconds. I'm using the development branch of Precise, if this isn't an issue in the released version I'll close this as being too localized, but I'm unable to test it now.

    Read the article

  • lubuntu notify-send remove limit of 21?

    - by giuspen
    sending notifications with notify-send in lubuntu notify-send -i error -t 1000 "Error" "error notification" I can send only 21 of them, after that no more notifications sent, the only way to receive more notifications is to click on the panel where there's a letter with the number 21 and then click on the button "clear all notifications". Is there a way to avoid the need to go clicking the button, also is there a way to remove at all that letter with number of notifications received? UPDATE: I realize that notification-daemon (0.7.3) is used. I downloaded the sources and edited the source code (nd-queue.c - on_bubble_destroyed) to do not buffer but always destroy the bubbles but I would prefer another way...

    Read the article

  • WPF Notify changes on object

    - by Erik Z
    I have a gridview were I define some columns, like this... <GridViewColumn.CellTemplate> <DataTemplate> <TextBlock Text="{Binding MyProp}" /> </DataTemplate> </GridViewColumn.CellTemplate> I bind my gridview to a collection and implemts INotifyPropertyChanged in the property MyProp. This works well and any changes of MyProp are reflected to the gridview. If I add another column that is bound to the object itself I dont get any notifications/updates. My code... <GridViewColumn.CellTemplate> <DataTemplate> <TextBlock Text="{Binding Converter={StaticResource myConverter}}"/> </DataTemplate> </GridViewColumn.CellTemplate> I think I need something like INotifyPropertyChanged for the object but I have no idea how to do this. Any suggestions?

    Read the article

  • WPF custom DependencyProperty notify changes

    - by morsanu
    Hey guys I have a class called MyComponent and it has a DependencyProperty caled BackgroundProperty. public class MyComponent { public MyBackground Background { get { return (MyBackground)GetValue(BackgroundProperty); } set { SetValue(BackgroundProperty, value); } } public static readonly DependencyProperty BackgroundProperty = DependencyProperty.Register("Background", typeof(MyBackground), typeof(MyComponent), new FrameworkPropertyMetadata(default(MyBackground), new PropertyChangedCallback(OnPropertyChanged))); } MyBackground is a class that derives from DependencyObject and it has some DependencyProperties. public class MyBackground : DependencyObject { public Color BaseColor { set { SetValue(BaseColorProperty, value); } get { return (Color)GetValue(BaseColorProperty); } } public static readonly DependencyProperty BaseColorProperty = DependencyProperty.Register("BaseColor", typeof(Color), typeof(MyBackground ), new UIPropertyMetadata(Colors.White)); [...] } Now, what I want is when a property from MyBackground is changed, MyComponent to be notified that MyBackground has changed and the PropertyChangedCallback named OnPropertyChanged to be called.

    Read the article

  • notify url is not called

    - by Jahangeer Ahmed
    Dim redirecturl As String = "" redirecturl = ConfigurationManager.AppSettings("papalUrl").ToString() & "us/cgi-bin/webscr?cmd=_cart&upload=1&business=" & ConfigurationManager.AppSettings("paypalemail").ToString() Dim j As Integer = 0 Dim dr1 As DataRow If ds.Tables("ReviewOrder").Rows.Count 0 Then Dim requestsFile As String = Server.MapPath("~/App_Data/PaymentRequests.xml") ' ds.Tables("ReviewOrder").WriteXml(requestsFile) For j = 0 To ds.Tables("ReviewOrder").Rows.Count - 1 dr1 = ds.Tables("ReviewOrder").Rows(j) redirecturl += "&item_name_" & j + 1 & "=" & dr1("varTitle") redirecturl += "&amount_" & j + 1 & "=" & dr1("flRate") redirecturl += "&image_url_" & j + 1 & "=" & ConfigurationManager.AppSettings("RSSurl").ToString() & dr1("imgImage") redirecturl += "&quantity_" & j + 1 & "=" & Convert.ToInt64(dr1("flQuantity")) ''redirecturl += "&item_name_2=Sample_testing2&amount_2=9.50" ''redirecturl += "&quantity_2=2" ''redirecturl += "&item_name_3=Sample_testing3" ''redirecturl += "&amount_3=8.50" ''redirecturl += "&quantity_3=3" redirecturl += "&custom_" & j + 1 & "=" & dr1("BasketID") Next End If redirecturl += "&currency=" & ConfigurationManager.AppSettings("CurrencyCode").ToString() redirecturl += "&first_name=" & firstName redirecturl += "&last_name=" & lastName redirecturl += "&city=" & city redirecturl += "&state=" & state redirecturl += "&zip=" & zip redirecturl += "&address1=" & address1 redirecturl += "&address2=" & address2 redirecturl += "&notify_url=" & Server.UrlEncode(ConfigurationManager.AppSettings("NotifyUrl").ToString() & "&rm=2") redirecturl += "&return=" & ConfigurationManager.AppSettings("SuccessURL").ToString() 'Failed return page url redirecturl += "&cancel_return=" & ConfigurationManager.AppSettings("FailedURL").ToString() Page.ClientScript.RegisterClientScriptBlock(Me.GetType(), "Redirect", "window.parent.location='" & redirecturl & "';", True)

    Read the article

  • In which object should I implement wait()/notify()?

    - by Christopher Francisco
    I'm working in an Android project with multithreading. Basically I have to wait to the server to respond before sending more data. The data sending task is delimited by the flag boolean hasServerResponded so the Thread will loop infinitely without doing anything until the flag becomes true. Since this boolean isn't declared as volatile (yet), and also looping without doing anything wastes resources, I thought maybe I should use AtomicBoolean and also implement wait() / notify() mechanism. Should I use the AtomicBoolean object notify() and wait() methods or should I create a lock Object?

    Read the article

  • Notify-osd -- Now with 70% Less Annoy :-)

    <b>SilverWav's Journal:</b> "Reduce the notify-osd time-out to 3 seconds, rather than the default 10. Its amazing how much this changed my appreciation of the notifications... I have found the annoyance is mainly based on them being on screen too long"

    Read the article

  • How to display reboot required user notification after installing a custom package in linux?

    - by user284588
    After installing a custom package I should force a reboot of the system. I looked at couple of solutions to this use notify-send to display user notification followed by a reboot command, which did work as planned. But the user notification is only shown when I install the package from command line and not when I installed through Software Center. I came across some posts where they suggested adding the following to the postinst script [ -x /usr/share/update-notifier/notify-reboot-required ] && \ /usr/share/update-notifier/notify-reboot-required || true Tried including the above in the postinst script but all it does is updating the two files /var/run/reboot-required.pkgs and /var/run/reboot-required with restart information. It neither displayed user-notification nor rebooted the system after package is installed. Is there a way to display reboot required user notification in Ubuntu/Fedora/Open SUSE ?

    Read the article

  • Why are notifications appearing in the invisible black zone above my monitor ?

    - by Capt.Nemo
    I've got two monitors, with the right side one being slightly lower in the display settings. However any notifications I receive from notify-osd (including pidgin, notify-send etc) are sent to the top-most part of the right monitor screen, which results it in being invisible. And here's a pic of my monitor preferences : I'd earlier used the Wallpaper plugin in compiz to stitch my desktops, and then uninstalled compiz-extras. I'm using Ubuntu 11.04 in classic mode.

    Read the article

  • Hidden DNS master only sending notify to one slave

    - by Rob
    My hidden DNS master is only sending notifies to one of the name servers for a zone I have 3 named servers ns0,ns1 & ns2 all running bind 9.7.3.dfsg-1ubuntu4.1. When an update is processed the master (ns0) seems to behave normally. ns0 (192.168.2.50) zone domain.org/IN: sending notifies (serial 2012060703) client 192.168.2.52#42892: transfer of 'domain.org/IN': AXFR-style IXFR started: TSIG rndc-key client 192.168.2.52#42892: transfer of 'domain.org/IN': AXFR-style IXFR ended ns2 (192.168.2.52) client 192.168.2.50#3762: received notify for zone 'domain.org': TSIG 'rndc-key' zone domain.org/IN: Transfer started. transfer of 'domain.org/IN' from 192.168.2.50#53: connected using 192.168.2.52#55747 zone domain.org/IN: transferred serial 2012060704: TSIG 'rndc-key' transfer of 'domain.org/IN' from 192.168.2.50#53: Transfer completed: 1 messages, 34 records, 1028 bytes, 0.001 secs (1028000 bytes/sec) Nothing happens on ns1. I've turned up the logging level but there's no information in syslog about the actual name servers bind has sent notifications to so I guess this is something it doesn't log. I've also tried watching tcpdump, it never makes any attempt to notify ns1 only ns2 192.168.2.50.56278 > 192.168.2.52.53: [udp sum ok] 56418 notify [b2&3=0x2400] [1a] [1au] ? SOA? domain.org. domain.org. [0s] SOA ns1.domain.net. dnsmaster.domain.net. ? 2012060801 10800 3600 604800 3600 ar: rndc-key. ANY [0s] TSIG hmac-md5.sig-alg.reg.int. fudge=300 maclen=16 origid=56418 error=0 otherlen=0 (174) the authoritive zone has both ns1 and ns2 records $ORIGIN domain.org. $TTL 3h @ IN SOA ns1.domain.net. dnsmaster.domain.net. ( 2012060801 ; Serial yyyymmddnn 3h ; Refresh After 3 hours 1h ; Retry Retry after 1 hour 1w ; Expire after 1 week 1h ) ; Minimum negative caching of 1 hour @ 3600 IN NS ns1.domain.net. @ 3600 IN NS ns2.domain.net. // Edit I have added also-notify {192.168.2.51;192.168.2.52;}; explicitly to the zone file and it all works fine, both ns1 and ns2 get notify messages and transfers succeed. I was under the impression bind would automatically send notifies to all NS records on a zone, maybe it's bugged?

    Read the article

  • Java - when to use notify or notifyAll?

    - by mdma
    Why does java.lang.Object have two notify methods - notify and notifyAll? It seems that notifyAll does at least everything notify does, so why not just use notifyAll all the time? If notifyAll is used instead of notify, is the program still correct, and vice versa? What influences the choice between these two methods?

    Read the article

  • problem in jquery notify bar on submit form using php or zf

    - by user1400
    hi guys in my application on zend framework i use of 'jQuery Notify Bar' plugin for display messages, i'd like to show message when my form submit ,the other page is opened and notify bar be open until the other page is completely load and even some second more but the problem is that notify bar show for short Moment and when the other page begin to load , notify bar is closed, and the delay property is not effect to that $('#myForm').submit(function(){ $.notifyBar({ html: "Thank you, your settings were updated!", **delay: 20000,** animationSpeed: "normal" }); how to show notify bar in the other page too? thanks

    Read the article

  • how to show jquery notify bar on submit form using php or zf

    - by user1400
    hi guys in my application on zend framework i use of 'jQuery Notify Bar' plugin for display messages, i'd like to show message when my form submit ,the other page is opened and notify bar be open until the other page is completely load and even some second more but the problem is that notify bar show for short Moment and when the other page begin to load , notify bar is closed, and the delay property is not effect to that $('#myForm').submit(function(){ $.notifyBar({ html: "Thank you, your settings were updated!", **delay: 20000,** animationSpeed: "normal" }); how to show notify bar in the other page too? thanks

    Read the article

  • Using a back-end mechanism to copy files to DB and notify the application

    - by BDotA
    This Scenario: User copies large files to a local folder. I want to watch that folder and when a new file is dropped then go and copy it to Database, so later when coping is done I can actually use it in my application. ( A C# WinForms App). It would be awesome to also find a way to somehow get notified in the Application that hey copying the file to DB is finished and ready for use... I am using C#.net, Windows... What solutions/architecture do you suggest for this? For example having a windows service running all the time watching that folder, when something copied goes and write it to DB ... then how about getting notified? MSMQ is something I can use? don't know much about it yet. Thanks.

    Read the article

  • Tips on how to notify a user of new features in your game

    - by brent777
    I have noticed a problem when releasing new features for a game that I wrote for Android and published on Google Play Store. Because my game is "stage-based" - and not a game like Hay Day, for example, where users will just go into the game every day since it can't really be finished - my users are not aware of new features that I release for the game. For example, if I publish a new version of my game and it contains a couple new stages, most of their devices will just auto-update the game and they don't even notice this and think to check out what's new. So this is why an approach like popping open a dialog that showcases the new feature(s) when they open the game for the first time after the update was done is not really sufficient. I am looking for some tips on an approach that will draw my users back into the game and then they could read more detail about new features on such a dialog. I was thinking of something like a notification that tells them to check out the new features after an update is done but I am not sure if this is a good idea. Any suggestions to help me solve this problem would be awesome.

    Read the article

  • Fixing USB drive auto-notify

    - by steevc
    Yesterday I was copying files from SD cards, but at some point they stopped auto-mounting. Didn't notice any errors. I can still mount by right-clicking the appropriate file in /dev in Konqueror. UPDATE: Slight correction. The drives never automounted, but I've stopped getting the notification that a drive is plugged in. What processes should I be checking? Something in Device Actions? I'm using Kubuntu 10.04

    Read the article

  • Tips on how to notify a user of new features in your game (Android)

    - by brent777
    I have noticed a problem when releasing new features for a game that I wrote for Android and published on Google Play Store. Because my game is "stage-based" - and not a game like Hay Day, for example, where users will just go into the game every day since it can't really be finished - my users are not aware of new features that I release for the game. For example, if I publish a new version of my game and it contains a couple new stages, most of their devices will just auto-update the game and they don't even notice this and think to check out what's new. So this is why an approach like popping open a dialog that showcases the new feature(s) when they open the game for the first time after the update was done is not really sufficient. I am looking for some tips on an approach that will draw my users back into the game and then they could read more detail about new features on such a dialog. I was thinking of something like a notification that tells them to check out the new features after an update is done but I am not sure if this is a good idea. Any suggestions to help me solve this problem would be awesome.

    Read the article

  • mercurial .hgrc notify hook

    - by Eeyore
    Could someone tell me what is incorrect in my .hgrc configuration? I am trying to use gmail to send a e-mail after each push and/or commit. .hgrc [paths] default = ssh://www.domain.com/repo/hg [ui] username = intern <[email protected]> ssh="C:\Program Files (x86)\Mercurial\plink.exe" -ssh -i "C:\Program Files (x86)\Mercurial\key.pub" [extensions] hgext.notify = [hooks] changegroup.notify = python:hgext.notify.hook incoming.notify = python:hgext.notify.hook [email] from = [email protected] [smtp] host = smtp.gmail.com username = [email protected] password = sure port = 587 tls = true [web] baseurl = http://dev/... [notify] sources = serve push pull bundle test = False config = /path/to/subscription/file template = \ndetails: {baseurl}{webroot}/rev/{node|short}\nchangeset: {rev}:{node|short}\nuser: {author}\ndate: {date|date}\ndescription:\n{desc}\n maxdiff = 300 Error Incoming comand failed for P/project. running ""C:\Program Files (x86)\Mercurial\plink.exe" -ssh -i "C:\Program Files (x86)\Mercurial\key.pub" [email protected] "hg -R repo/hg serve --stdio"" sending hello command sending between command remote: FATAL ERROR: Server unexpectedly closed network connection abort: no suitable response from remote hg! , error code: -1 running ""C:\Program Files (x86)\Mercurial\plink.exe" -ssh -i "C:\Program Files (x86)\Mercurial\key.pub" [email protected] "hg -R repo/hg serve --stdio"" sending hello command sending between command remote: FATAL ERROR: Server unexpectedly closed network connection abort: no suitable response from remote hg!

    Read the article

1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >