Search Results

Search found 7 results on 1 pages for 'odr'.

Page 1/1 | 1 

  • If I don't odr-use a variable, can I have multiple definitions of it across translation units?

    - by sftrabbit
    The standard seems to imply that there is no restriction on the number of definitions of a variable if it is not odr-used (§3.2/3): Every program shall contain exactly one definition of every non-inline function or variable that is odr-used in that program; no diagnostic required. It does say that any variable can't be defined multiple times within a translation unit (§3.2/1): No translation unit shall contain more than one definition of any variable, function, class type, enumeration type, or template. But I can't find a restriction for non-odr-used variables across the entire program. So why can't I compile something like the following: // other.cpp int x; // main.cpp int x; int main() {} Compiling and linking these files with g++ 4.6.3, I get a linker error for multiple definition of 'x'. To be honest, I expect this, but since x is not odr-used anywhere (as far as I can tell), I can't see how the standard restricts this. Or is it undefined behaviour?

    Read the article

  • Getting Error System.Runtime.InteropServices.COMException

    - by Savan Parmar
    Hey All, I am using Vb.Net to Create Labels in Microsoft. For that i am using below mantioend Code. Public Sub CreateLabel(ByVal StrFilter As String, ByVal Path As String) WordApp = CreateObject("Word.Application") ''Add a new document. WordDoc = WordApp.Documents.Add() Dim oConn As SqlConnection = New SqlConnection(connSTR) oConn.Open() Dim oCmd As SqlCommand Dim oDR As SqlDataReader oCmd = New SqlCommand(StrFilter, oConn) oDR = oCmd.ExecuteReader Dim intI As Integer Dim FilePath As String = "" With WordDoc.MailMerge With .Fields Do While oDR.Read For intI = 0 To oDR.FieldCount - 1 .Add(WordApp.Selection.Range, oDR.Item(intI)) Next Loop End With Dim objAutoText As Word.AutoTextEntry = WordApp.NormalTemplate.AutoTextEntries.Add("MyLabelLayout", WordDoc.Content) WordDoc.Content.Delete() .MainDocumentType = Word.WdMailMergeMainDocType.wdMailingLabels FilePath = CreateSource(StrFilter) .OpenDataSource(FilePath) Dim NewLabel As Word.CustomLabel = WordApp.MailingLabel.CustomLabels.Add("MyLabel", False) WordApp.MailingLabel.CreateNewDocument(Name:="MyLabel", Address:="", AutoText:="MyLabelLayout") objAutoText.Delete() .Destination = Word.WdMailMergeDestination.wdSendToNewDocument WordApp.Visible = True .Execute() End With oConn.Close() WordDoc.Close() End Sub Private Function CreateSource(ByVal StrFilter As String) As String Dim CnnUser As SqlConnection = New SqlConnection(connSTR) Dim sw As StreamWriter = File.CreateText("C:\Mail.Txt") Dim Path As String = "C:\Mail.Txt" Dim StrHeader As String = "" Try Dim SelectCMD As SqlCommand = New SqlCommand(StrFilter, CnnUser) Dim oDR As SqlDataReader Dim IntI As Integer SelectCMD.CommandType = CommandType.Text CnnUser.Open() oDR = SelectCMD.ExecuteReader For IntI = 0 To oDR.FieldCount - 1 StrHeader &= oDR.GetName(IntI) & " ," Next StrHeader = Mid(StrHeader, 1, Len(StrHeader) - 2) sw.WriteLine(StrHeader) sw.Flush() sw.Close() StrHeader = "" Do While oDR.Read For IntJ As Integer = 0 To oDR.FieldCount - 1 StrHeader &= oDR.GetString(IntJ) & " ," Next Loop StrHeader = Mid(StrHeader, 1, Len(StrHeader) - 2) sw = File.AppendText(Path) sw.WriteLine(StrHeader) CnnUser.Close() sw.Flush() sw.Close() Catch ex As Exception MessageBox.Show(ex.Message, "TempID", MessageBoxButtons.OK, MessageBoxIcon.Error) End Try Return Path End Function Now when i am running the programm i am getting this error.I tried hard but not able to locate what could be the problem the error is:- System.Runtime.InteropServices.COMException --Horizontal and vertical pitch must be greater than or equal to the label width and height, respectively. Even though i tried to set the Horizontal and vertical pitch programatically but it gives same err. Plz if any one can help

    Read the article

  • Type casting in TPC inheritance

    - by Mohsen Esmailpour
    I have several products like HotelProduct, FlightProduct ... which derived from BaseProduct class. The table of these products will be generated in TPC manner in database. There is OrderLine class which has a BaseProduct. My problem is when i select an OrderLine with related product i don't know how cast BaseProduct to derived product. for example i have this query: var order = (from odr in _context.Orders join orderLine in _context.OrderLines on odr.Id equals orderLine.OrderId join hotel in _context.Products.OfType<HotelProduct>() on orderLine.ProductId equals hotel.Id where odr.UserId == userId && odr.Id == orderId orderby odr.OrderDate descending select odr).SingleOrDefault(); In OrderLine i have BaseProduct properties not properties of HotelProduct. Is there any way to cast BaseProduct to derived class in OrderLine or any other solutions ?

    Read the article

  • Data adapter not filling my dataset

    - by Doug Ancil
    I have the following code: Imports System.Data.SqlClient Public Class Main Protected WithEvents DataGridView1 As DataGridView Dim instForm2 As New Exceptions Private Sub Button1_Click_1(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles startpayrollButton.Click Dim ssql As String = "select MAX(payrolldate) AS [payrolldate], " & _ "dateadd(dd, ((datediff(dd, '17530107', MAX(payrolldate))/7)*7)+7, '17530107') AS [Sunday]" & _ "from dbo.payroll" & _ " where payrollran = 'no'" Dim oCmd As System.Data.SqlClient.SqlCommand Dim oDr As System.Data.SqlClient.SqlDataReader oCmd = New System.Data.SqlClient.SqlCommand Try With oCmd .Connection = New System.Data.SqlClient.SqlConnection("Initial Catalog=mdr;Data Source=xxxxx;uid=xxxxx;password=xxxxx") .Connection.Open() .CommandType = CommandType.Text .CommandText = ssql oDr = .ExecuteReader() End With If oDr.Read Then payperiodstartdate = oDr.GetDateTime(1) payperiodenddate = payperiodstartdate.AddSeconds(604799) Dim ButtonDialogResult As DialogResult ButtonDialogResult = MessageBox.Show(" The Next Payroll Start Date is: " & payperiodstartdate.ToString() & System.Environment.NewLine & " Through End Date: " & payperiodenddate.ToString()) If ButtonDialogResult = Windows.Forms.DialogResult.OK Then exceptionsButton.Enabled = True startpayrollButton.Enabled = False End If End If oDr.Close() oCmd.Connection.Close() Catch ex As Exception MessageBox.Show(ex.Message) oCmd.Connection.Close() End Try End Sub Private Sub Button2_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles exceptionsButton.Click Dim connection As System.Data.SqlClient.SqlConnection Dim adapter As System.Data.SqlClient.SqlDataAdapter = New System.Data.SqlClient.SqlDataAdapter Dim connectionString As String = "Initial Catalog=mdr;Data Source=xxxxx;uid=xxxxx;password=xxxxx" Dim ds As New DataSet Dim _sql As String = "SELECT [Exceptions].Employeenumber,[Exceptions].exceptiondate, [Exceptions].starttime, [exceptions].endtime, [Exceptions].code, datediff(minute, starttime, endtime) as duration INTO scratchpad3" & _ " FROM Employees INNER JOIN Exceptions ON [Exceptions].EmployeeNumber = [Exceptions].Employeenumber" & _ " where [Exceptions].exceptiondate between @payperiodstartdate and @payperiodenddate" & _ " GROUP BY [Exceptions].Employeenumber, [Exceptions].Exceptiondate, [Exceptions].starttime, [exceptions].endtime," & _ " [Exceptions].code, [Exceptions].exceptiondate" connection = New SqlConnection(connectionString) connection.Open() Dim _CMD As SqlCommand = New SqlCommand(_sql, connection) _CMD.Parameters.AddWithValue("@payperiodstartdate", payperiodstartdate) _CMD.Parameters.AddWithValue("@payperiodenddate", payperiodenddate) adapter.SelectCommand = _CMD Try adapter.Fill(ds) If ds Is Nothing OrElse ds.Tables.Count = 0 OrElse ds.Tables(0).Rows.Count = 0 Then 'it's empty MessageBox.Show("There was no data for this time period. Press Ok to continue", "No Data") connection.Close() Exceptions.saveButton.Enabled = False Exceptions.Hide() Else connection.Close() End If Catch ex As Exception MessageBox.Show(ex.ToString) connection.Close() End Try Exceptions.Show() End Sub Private Sub payrollButton_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles payrollButton.Click Payrollfinal.Show() End Sub End Class and when I run my program and press this button Private Sub Button2_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles exceptionsButton.Click I have my date range within a time that I know that my dataset should produce a result, but when I put a line break in my code here: adapter.Fill(ds) and look at it in debug, I show a table value of 0. If I run the same query that I have to produce these results in sql analyser, I see 1 result. Can someone see why my query on my form produces a different result than the sql analyser does? Also here is my schema for my two tables: Exceptions employeenumber varchar no 50 yes no no SQL_Latin1_General_CP1_CI_AS exceptiondate datetime no 8 yes (n/a) (n/a) NULL starttime datetime no 8 yes (n/a) (n/a) NULL endtime datetime no 8 yes (n/a) (n/a) NULL duration varchar no 50 yes no no SQL_Latin1_General_CP1_CI_AS code varchar no 50 yes no no SQL_Latin1_General_CP1_CI_AS approvedby varchar no 50 yes no no SQL_Latin1_General_CP1_CI_AS approved varchar no 50 yes no no SQL_Latin1_General_CP1_CI_AS time timestamp no 8 yes (n/a) (n/a) NULL employees employeenumber varchar no 50 no no no SQL_Latin1_General_CP1_CI_AS name varchar no 50 no no no SQL_Latin1_General_CP1_CI_AS initials varchar no 50 no no no SQL_Latin1_General_CP1_CI_AS loginname1 varchar no 50 yes no no SQL_Latin1_General_CP1_CI_AS

    Read the article

  • Combine config-paramters with parameters passed from commanline

    - by Frederik
    I have created a SSIS-package that imports a file into a table (simple enough). I have some variables, a few set in a config-file such as server, database, importfolder. at runtime I want to pass the filename. This is done through a stored procedure using dtexec. When setting the paramters throught the configfile it works fine also when setting all parameters in the procedure and passing them with the \Set statement (se below). when I try to combine the config-version with settings parameters on the fly I get an error refering to the config-files path that was set at design time. Has anybody come across this and found a solution for it? Regards Frederik DECLARE @SSISSTR VARCHAR(8000), @DataBaseServer VARCHAR(100), @DataBaseName VARCHAR(100), @PackageFilePath VARCHAR(200), @ImportFolder VARCHAR(200), @HandledFolder VARCHAR(200), @ConfigFilePath VARCHAR(200), @SSISreturncode INT; /* DEBUGGING DECLARE @FileName VARCHAR(100), @SelectionId INT SET @FileName = 'Test.csv'; SET @SelectionId = 366; */ SET @PackageFilePath = '/FILE "Y:\SSIS\Packages\PostalCodeSelectionImport\ImportPackage.dtsx" '; SET @DataBaseServer = 'STOSWVUTVDB01\DEV_BSE'; SET @DataBaseName = 'BSE_ODR'; SET @ImportFolder = '\\Stoswvutvbse01\Application\FileLoadArea\ODR\\'; SET @HandledFolder = '\\Stoswvutvbse01\Application\FileLoadArea\ODR\Handled\\'; --SET @ConfigFilePath = '/CONFIGFILE "Y:\SSIS\Packages\PostalCodeSelectionImport\Configuration\DEV_BSE.dtsConfig" '; ----now making "dtexec" SQL from dynamic values SET @SSISSTR = 'DTEXEC ' + @PackageFilePath; -- + @ConfigFilePath; SET @SSISSTR = @SSISSTR + ' /SET \Package.Variables[User::SelectionId].Properties[Value];' + CAST( @SelectionId AS VARCHAR(12)); SET @SSISSTR = @SSISSTR + ' /SET \Package.Variables[User::DataBaseServer].Properties[Value];"' + @DataBaseServer + '"'; SET @SSISSTR = @SSISSTR + ' /SET \Package.Variables[User::ImportFolder].Properties[Value];"' + @ImportFolder + '" '; SET @SSISSTR = @SSISSTR + ' /SET \Package.Variables[User::DataBaseName].Properties[Value];"' + @DataBaseName + '" '; SET @SSISSTR = @SSISSTR + ' /SET \Package.Variables[User::ImportFileName].Properties[Value];"' + @FileName + '" '; SET @SSISSTR = @SSISSTR + ' /SET \Package.Variables[User::HandledFolder].Properties[Value];"' + @HandledFolder + '" '; -- Now execute dynamic SQL by using EXEC. EXEC @SSISreturncode = xp_cmdshell @SSISSTR;

    Read the article

  • extern(al) problem

    - by Knowing me knowing you
    Why can't I compile this code? //main #include "stdafx.h" #include "X.h" #include "Y.h" //#include "def.h" extern X operator*(X, Y);//HERE ARE DECLARED EXTERNAL *(X,Y) AND f(X) extern int f(X); /*GLOBALS*/ X x = 1; Y y = x; int i = 2; int _tmain(int argc, _TCHAR* argv[]) { i + 10; y + 10; y + 10 * y; //x + (y + i); x * x + i; f(7); //f(y); //y + y; //106 + y; return 0; } //X struct X { int i; X(int value):i(value) { } X operator+(int value) { return X(i + value); } operator int() { return i; } }; //Y struct Y { int i; Y(X x):i(x.i) { } Y operator+(X x) { return Y(i + x.i); } }; //def.h int f(X x); X operator*(X x, Y y); //def.cpp #include "stdafx.h" #include "def.h" #include "X.h" #include "Y.h" int f(X x) { return x; } X operator*(X x, Y y) { return x * y; } I'm getting err msg: Error 2 error LNK2019: unresolved external symbol "int __cdecl f(struct X)" Error 3 error LNK2019: unresolved external symbol "struct X __cdecl operator*(struct X,struct Y)" Another interesting thing is that if I place the implementation in def.h file it does compiles without errs. But then what about def.cpp? Why I'm not getting err msg that function f(X) is already defined? Here shouldn't apply ODR rule. Second concern I'm having is that if in def.cpp I change the return type of f from int to double intelliSense underlines this as an error but program still compiles? Why?

    Read the article

  • Tunnel is up but cannot ping directly connected network

    - by drmanalo
    We configured a site-to-site VPN and here is the topology. I control the network on the left but not the one on the right. All devices in our network has public IPs. Server---ASA5505---Cisco887======Internet=====ASA5510---devices I can see the tunnel is up and can do extended ping using a loopback interface. From the 10.175 and 10.165 networks, they can also ping my loopback address. I can also dial in using a Cisco VPN client, and can connect to the devices on the right. #show crypto session Crypto session current status Interface: Vlan3 Profile: xxx-profile Session status: UP-ACTIVE Peer: 213.121.x.x port 500 IKEv1 SA: local 77.245.x.x/500 remote 213.121.x.x/500 Active IPSEC FLOW: permit ip 10.0.20.0/255.255.255.240 10.175.0.0/255.255.128.0 Active SAs: 0, origin: crypto map IPSEC FLOW: permit ip 10.0.20.0/255.255.255.240 10.165.0.0/255.255.192.0 Active SAs: 2, origin: crypto map #ping 10.165.29.39 source loopback 2 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 10.165.29.39, timeout is 2 seconds: Packet sent with a source address of 10.0.20.1 !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 16/17/20 ms My problem is the devices on the right cannot reach my server. They could only ping the loopback address and nothing else. I'm pasting some diagnostics related to routing thinking perhaps routing is my issue. I can paste all the running-config on my side of network if needed. #show ip int brief Interface IP-Address OK? Method Status Protocol ATM0 unassigned YES NVRAM administratively down down Ethernet0 unassigned YES NVRAM administratively down down FastEthernet0 unassigned YES unset up up connected to ASA FastEthernet1 unassigned YES unset administratively down down FastEthernet2 unassigned YES unset administratively down down FastEthernet3 unassigned YES unset up up Loopback1 10.0.20.65 YES NVRAM up up Loopback2 10.0.20.1 YES NVRAM up up Virtual-Template1 77.245.x.x YES unset up down Virtual-Template2 77.245.x.x YES unset up down Vlan1 unassigned YES unset down down Vlan3 77.245.x.x YES NVRAM up up connected to the Internet #show run | section ip route ip route 0.0.0.0 0.0.0.0 77.245.x.x ip route 213.121.240.36 255.255.255.255 Vlan3 #show access-list Extended IP access list 102 10 permit ip 10.0.20.0 0.0.0.15 10.175.0.0 0.0.127.255 (3332 matches) 20 permit ip 10.0.20.0 0.0.0.15 10.165.0.0 0.0.63.255 (3498 matches) #show vlan-switch VLAN Name Status Ports ---- -------------------------------- --------- ------------------------------- 1 default active 3 VLAN0003 active Fa0, Fa1, Fa2, Fa3 1002 fddi-default act/unsup 1003 token-ring-default act/unsup 1004 fddinet-default act/unsup 1005 trnet-default act/unsup #show ip route Codes: L - local, C - connected, S - static, R - RIP, M - mobile, B - BGP D - EIGRP, EX - EIGRP external, O - OSPF, IA - OSPF inter area N1 - OSPF NSSA external type 1, N2 - OSPF NSSA external type 2 E1 - OSPF external type 1, E2 - OSPF external type 2 i - IS-IS, su - IS-IS summary, L1 - IS-IS level-1, L2 - IS-IS level-2 ia - IS-IS inter area, * - candidate default, U - per-user static route o - ODR, P - periodic downloaded static route, H - NHRP, l - LISP + - replicated route, % - next hop override Gateway of last resort is 77.245.x.x to network 0.0.0.0 S* 0.0.0.0/0 [1/0] via 77.245.x.x 10.0.0.0/8 is variably subnetted, 5 subnets, 3 masks C 10.0.20.0/28 is directly connected, Loopback2 L 10.0.20.1/32 is directly connected, Loopback2 C 10.0.20.64/28 is directly connected, Loopback1 L 10.0.20.65/32 is directly connected, Loopback1 S 10.165.0.0/18 [1/0] via 213.121.x.x 77.0.0.0/8 is variably subnetted, 3 subnets, 3 masks S 77.0.0.0/8 [1/0] via 77.245.x.x C 77.245.x.x/29 is directly connected, Vlan3 L 77.245.x.x/32 is directly connected, Vlan3 213.121.x.0/32 is subnetted, 1 subnets S 213.121.x.x is directly connected, Vlan3 I read some of the posts here which lead to NATing issue but I'not sure of my next step. Should I translate my public address to private and route it to the loopback address? (only guessing) CISCO VPN site to site Site-to-Site VPN between two ASA 5505s only working in one direction Hope someone could help. Thanks in advance!

    Read the article

1