Search Results

Search found 4298 results on 172 pages for 'david thomas garcia'.

Page 10/172 | < Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >

  • How can I use GPRename's regex feature to reinsert the matched-group into the 'replace'?

    - by David Thomas
    I've been using GPRename to batch-rename files; this is rather more efficient than individually correcting each file, but still seems to be less efficient than it might be, primarily because either I don't understand the regex syntax used, or because the regex implementation is incomplete1 Given a list of files of the following syntax: (01) - title of file1.avi (02) - title of file2.avi (03) - title of file3.avi I attempted to use the 'replace' (with the regex option selected, the case-sensitive option deselected): (\(\d{2}\)) The preview then shows (given that I've specified no 'replace with' option as yet): title of file1.avi title of file2.avi title of file3.avi Which is great, clearly the regex is identifying the correct group (the (01)). Now, what I was hoping to do (using the JavaScript syntax) in the 'replace with' option is use: $1 (I also tried using '$1', \1 and '\1') This was just to check that I could access the matched group, and it seems I can't, the matched group is, as I suppose might be expected, replaced with the literal replacement string. So, my question: is it possible to match a particular group of characters, in this case the numbers within the brackets, and then insert those into the replacement string? Therefore: (01) title of file1.avi (02) title of file2.avi (03) title of file3.avi Becomes: 01 title of file1.avi 02 title of file2.avi 03 title of file3.avi I absolutely suspect the former, personally.

    Read the article

  • How can I secure an installation of MediaWiki?

    - by Thomas Owens
    I want to run an installation of MediaWiki as a Internet-accessible personal wiki, running on wiki.mysite.com. However, I want to ensure that I am the only one who can read and write to this wiki. In the future, I may explicitly give other people read and/or read/write access, so the method of securing the wiki should account for that as well. I see two options: I can use some MediaWiki plugin or I can secure the subdomain with HTTP authentication. However, I'm not sure what the advantages and disadvantages of either are in the long run. Suggestions or advice as to what plugins or authentication methods might be most reliable?

    Read the article

  • Hosting a website on Heroku.... I know how to, but im running into problems!

    - by Thomas Miller
    I'm starting to learn more on the back-end scale of programing. Recently I started up Heroku for the second or third time. This time I actually installed the Git update to my Mac and installed Heroku in the terminal. I wanted to upload a static html site with the sinatra gem. Everything worked out fine inside the terminal, though I added sinatra after I got everything working and the file with the site hooked up to Heroku. In my logs I did see that I was missing the sinatra gem, so I installed it. My site contains both the proper app.rb and config.ru files. I have nothing showing up online. Just a blank screen! Contacting Heroku on this problem has been very difficult. I get a responce every day, and on every day I respond with a question to the answer that didn't help me at all. 2011-05-18T00:25:20+00:00 app[web.1]: 71.198.0.51 - - [17/May/2011 17:25:20] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T00:25:20+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=2ms bytes=313 2011-05-18T00:25:26+00:00 app[web.1]: 71.198.0.51 - - [17/May/2011 17:25:26] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T00:25:26+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=5ms bytes=313 2011-05-17T18:25:51-07:00 heroku[web.1]: Idling 2011-05-17T18:26:01-07:00 heroku[web.1]: State changed from up to down 2011-05-18T01:26:01+00:00 heroku[web.1]: Stopping process with SIGTERM 2011-05-18T01:26:01+00:00 app[web.1]: Stopping ... 2011-05-18T01:26:02+00:00 heroku[web.1]: Process exited 2011-05-17T20:12:46-07:00 heroku[web.1]: Unidling 2011-05-17T20:12:47-07:00 heroku[web.1]: State changed from created to starting 2011-05-18T03:12:48+00:00 heroku[web.1]: Starting process with command: thin -p 40055 -e production -R /home/heroku_rack/heroku.ru start 2011-05-18T03:12:49+00:00 app[web.1]: Thin web server (v1.2.6 codename Crazy Delicious) 2011-05-18T03:12:49+00:00 app[web.1]: Maximum connections set to 1024 2011-05-18T03:12:49+00:00 app[web.1]: Listening on 0.0.0.0:40055, CTRL+C to stop 2011-05-18T03:12:50+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=9954ms service=6ms bytes=565 2011-05-18T03:12:50+00:00 app[web.1]: 70.91.206.114 - - [17/May/2011 20:12:50] "GET /style.css HTTP/1.1" 200 - 0.0012 2011-05-18T03:12:50+00:00 heroku[router]: GET pxlc.heroku.com/style.css dyno=web.1 queue=0 wait=0ms service=2ms bytes=269 2011-05-17T20:12:50-07:00 heroku[web.1]: State changed from starting to up 2011-05-18T03:12:51+00:00 app[web.1]: 70.91.206.114 - - [17/May/2011 20:12:51] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T03:12:51+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=4ms bytes=313 2011-05-18T03:13:05+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=0ms service=5ms bytes=565 2011-05-18T03:13:05+00:00 app[web.1]: 70.91.206.114 - - [17/May/2011 20:13:05] "GET / HTTP/1.1" 200 293 0.0011 2011-05-18T03:13:05+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=2ms bytes=313 2011-05-18T03:13:05+00:00 app[web.1]: 70.91.206.114 - - [17/May/2011 20:13:05] "GET /favicon.ico HTTP/1.1" 404 18 0.0007 2011-05-18T03:57:05+00:00 app[web.1]: 172.18.33.56, 58.96.134.66 - - [17/May/2011 20:57:05] "GET / HTTP/1.1" 200 293 0.0007 2011-05-18T03:57:05+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=0ms service=4ms bytes=565 2011-05-18T03:57:05+00:00 app[web.1]: 172.18.33.56, 58.96.134.66 - - [17/May/2011 20:57:05] "GET /style.css HTTP/1.1" 200 - 0.0007 2011-05-18T03:57:05+00:00 heroku[router]: GET pxlc.heroku.com/style.css dyno=web.1 queue=0 wait=0ms service=2ms bytes=269 2011-05-18T03:57:08+00:00 app[web.1]: 172.18.33.56, 58.96.134.66 - - [17/May/2011 20:57:08] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-17T21:58:27-07:00 heroku[web.1]: Idling 2011-05-18T04:58:30+00:00 heroku[web.1]: Stopping process with SIGTERM 2011-05-18T04:58:30+00:00 app[web.1]: Stopping ... 2011-05-18T04:58:30+00:00 heroku[web.1]: Process exited 2011-05-17T21:58:33-07:00 heroku[web.1]: State changed from up to down 2011-05-17T23:11:58-07:00 heroku[web.1]: Unidling 2011-05-17T23:11:58-07:00 heroku[web.1]: State changed from created to starting 2011-05-18T06:12:00+00:00 heroku[web.1]: Starting process with command: thin -p 40091 -e production -R /home/heroku_rack/heroku.ru start 2011-05-18T06:12:01+00:00 app[web.1]: Thin web server (v1.2.6 codename Crazy Delicious) 2011-05-18T06:12:01+00:00 app[web.1]: Maximum connections set to 1024 2011-05-18T06:12:01+00:00 app[web.1]: Listening on 0.0.0.0:40091, CTRL+C to stop 2011-05-18T06:12:01+00:00 app[web.1]: 183.97.156.226 - - [17/May/2011 23:12:01] "GET / HTTP/1.1" 200 293 0.0017 2011-05-18T06:12:02+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=3209ms service=5ms bytes=565 2011-05-18T06:12:03+00:00 app[web.1]: 183.97.156.226 - - [17/May/2011 23:12:03] "GET /style.css HTTP/1.1" 200 - 0.0019 2011-05-17T23:12:08-07:00 heroku[web.1]: State changed from starting to up 2011-05-18T00:13:13-07:00 heroku[web.1]: Idling 2011-05-18T00:13:16-07:00 heroku[web.1]: State changed from up to down 2011-05-18T07:13:16+00:00 heroku[web.1]: Stopping process with SIGTERM 2011-05-18T07:13:16+00:00 app[web.1]: Stopping ... 2011-05-18T07:13:17+00:00 heroku[web.1]: Process exited 2011-05-18T01:54:21-07:00 heroku[web.1]: Unidling 2011-05-18T01:54:21-07:00 heroku[web.1]: State changed from created to starting 2011-05-18T08:54:23+00:00 heroku[web.1]: Starting process with command: thin -p 59491 -e production -R /home/heroku_rack/heroku.ru start 2011-05-18T08:54:24+00:00 app[web.1]: Thin web server (v1.2.6 codename Crazy Delicious) 2011-05-18T08:54:24+00:00 app[web.1]: Maximum connections set to 1024 2011-05-18T08:54:24+00:00 app[web.1]: Listening on 0.0.0.0:59491, CTRL+C to stop 2011-05-18T01:54:28-07:00 heroku[web.1]: State changed from starting to up 2011-05-18T08:54:28+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=6943ms service=6ms bytes=565 2011-05-18T08:54:28+00:00 app[web.1]: 62.244.82.72 - - [18/May/2011 01:54:28] "GET / HTTP/1.1" 200 293 0.0018 2011-05-18T08:54:28+00:00 heroku[router]: GET pxlc.heroku.com/style.css dyno=web.1 queue=0 wait=0ms service=2ms bytes=269 2011-05-18T08:54:28+00:00 app[web.1]: 62.244.82.72 - - [18/May/2011 01:54:28] "GET /style.css HTTP/1.1" 200 - 0.0014 2011-05-18T08:54:28+00:00 app[web.1]: 62.244.82.72 - - [18/May/2011 01:54:28] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T08:54:28+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=1ms bytes=313 2011-05-18T08:54:28+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=4ms bytes=313 2011-05-18T08:54:28+00:00 app[web.1]: 62.244.82.72 - - [18/May/2011 01:54:28] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T08:54:28+00:00 app[web.1]: 62.244.82.72 - - [18/May/2011 01:54:28] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T08:54:28+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=1ms bytes=313 2011-05-18T02:55:23-07:00 heroku[web.1]: Idling 2011-05-18T02:55:33-07:00 heroku[web.1]: State changed from up to down 2011-05-18T09:55:34+00:00 heroku[web.1]: Stopping process with SIGTERM 2011-05-18T09:55:34+00:00 app[web.1]: Stopping ... 2011-05-18T09:55:34+00:00 heroku[web.1]: Process exited 2011-05-18T07:23:10-07:00 heroku[web.1]: State changed from created to starting 2011-05-18T14:23:12+00:00 heroku[web.1]: Starting process with command: thin -p 20560 -e production -R /home/heroku_rack/heroku.ru start 2011-05-18T14:23:13+00:00 app[web.1]: Thin web server (v1.2.6 codename Crazy Delicious) 2011-05-18T14:23:13+00:00 app[web.1]: Maximum connections set to 1024 2011-05-18T14:23:13+00:00 app[web.1]: Listening on 0.0.0.0:20560, CTRL+C to stop 2011-05-18T07:23:13-07:00 heroku[web.1]: State changed from starting to up 2011-05-18T14:23:14+00:00 app[web.1]: 12.183.19.10 - - [18/May/2011 07:23:14] "GET / HTTP/1.1" 200 293 0.0018 2011-05-18T14:23:14+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=0ms service=7ms bytes=565 2011-05-18T14:23:14+00:00 app[web.1]: 12.183.19.10 - - [18/May/2011 07:23:14] "GET /style.css HTTP/1.1" 200 - 0.0015 2011-05-18T14:23:14+00:00 heroku[router]: GET pxlc.heroku.com/style.css dyno=web.1 queue=0 wait=0ms service=2ms bytes=269 2011-05-18T14:23:14+00:00 app[web.1]: 12.183.19.10 - - [18/May/2011 07:23:14] "GET /favicon.ico HTTP/1.1" 404 18 0.0009 2011-05-18T14:23:14+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=2ms bytes=313 2011-05-18T08:24:03-07:00 heroku[web.1]: Idling 2011-05-18T08:24:07-07:00 heroku[web.1]: State changed from up to down 2011-05-18T15:24:07+00:00 heroku[web.1]: Stopping process with SIGTERM 2011-05-18T15:24:07+00:00 app[web.1]: Stopping ... 2011-05-18T17:34:27-07:00 heroku[web.1]: Unidling 2011-05-18T17:34:28-07:00 heroku[web.1]: State changed from created to starting 2011-05-19T00:34:29+00:00 heroku[web.1]: Starting process with command: thin -p 57621 -e production -R /home/heroku_rack/heroku.ru start 2011-05-18T17:34:31-07:00 heroku[web.1]: State changed from starting to up 2011-05-19T00:34:32+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=0ms service=5ms bytes=565 2011-05-19T00:34:32+00:00 app[web.1]: 97.83.58.74 - - [18/May/2011 17:34:32] "GET / HTTP/1.1" 200 293 0.0016 2011-05-19T00:34:32+00:00 app[web.1]: 97.83.58.74 - - [18/May/2011 17:34:32] "GET /style.css HTTP/1.1" 200 - 0.0011 2011-05-19T00:34:32+00:00 heroku[router]: GET pxlc.heroku.com/style.css dyno=web.1 queue=0 wait=0ms service=2ms bytes=269 2011-05-19T00:34:34+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=4ms bytes=313 2011-05-19T00:34:34+00:00 app[web.1]: 97.83.58.74 - - [18/May/2011 17:34:34] "GET /favicon.ico HTTP/1.1" 404 18 0.0007 2011-05-18T18:35:48-07:00 heroku[web.1]: Idling 2011-05-18T18:35:51-07:00 heroku[web.1]: State changed from up to down

    Read the article

  • Mocking the Unmockable: Using Microsoft Moles with Gallio

    - by Thomas Weller
    Usual opensource mocking frameworks (like e.g. Moq or Rhino.Mocks) can mock only interfaces and virtual methods. In contrary to that, Microsoft’s Moles framework can ‘mock’ virtually anything, in that it uses runtime instrumentation to inject callbacks in the method MSIL bodies of the moled methods. Therefore, it is possible to detour any .NET method, including non-virtual/static methods in sealed types. This can be extremely helpful when dealing e.g. with code that calls into the .NET framework, some third-party or legacy stuff etc… Some useful collected resources (links to website, documentation material and some videos) can be found in my toolbox on Delicious under this link: http://delicious.com/thomasweller/toolbox+moles A Gallio extension for Moles Originally, Moles is a part of Microsoft’s Pex framework and thus integrates best with Visual Studio Unit Tests (MSTest). However, the Moles sample download contains some additional assemblies to also support other unit test frameworks. They provide a Moled attribute to ease the usage of mole types with the respective framework (there are extensions for NUnit, xUnit.net and MbUnit v2 included with the samples). As there is no such extension for the Gallio platform, I did the few required lines myself – the resulting Gallio.Moles.dll is included with the sample download. With this little assembly in place, it is possible to use Moles with Gallio like that: [Test, Moled] public void SomeTest() {     ... What you can do with it Moles can be very helpful, if you need to ‘mock’ something other than a virtual or interface-implementing method. This might be the case when dealing with some third-party component, legacy code, or if you want to ‘mock’ the .NET framework itself. Generally, you need to announce each moled type that you want to use in a test with the MoledType attribute on assembly level. For example: [assembly: MoledType(typeof(System.IO.File))] Below are some typical use cases for Moles. For a more detailed overview (incl. naming conventions and an instruction on how to create the required moles assemblies), please refer to the reference material above.  Detouring the .NET framework Imagine that you want to test a method similar to the one below, which internally calls some framework method:   public void ReadFileContent(string fileName) {     this.FileContent = System.IO.File.ReadAllText(fileName); } Using a mole, you would replace the call to the File.ReadAllText(string) method with a runtime delegate like so: [Test, Moled] [Description("This 'mocks' the System.IO.File class with a custom delegate.")] public void ReadFileContentWithMoles() {     // arrange ('mock' the FileSystem with a delegate)     System.IO.Moles.MFile.ReadAllTextString = (fname => fname == FileName ? FileContent : "WrongFileName");       // act     var testTarget = new TestTarget.TestTarget();     testTarget.ReadFileContent(FileName);       // assert     Assert.AreEqual(FileContent, testTarget.FileContent); } Detouring static methods and/or classes A static method like the below… public static string StaticMethod(int x, int y) {     return string.Format("{0}{1}", x, y); } … can be ‘mocked’ with the following: [Test, Moled] public void StaticMethodWithMoles() {     MStaticClass.StaticMethodInt32Int32 = ((x, y) => "uups");       var result = StaticClass.StaticMethod(1, 2);       Assert.AreEqual("uups", result); } Detouring constructors You can do this delegate thing even with a class’ constructor. The syntax for this is not all  too intuitive, because you have to setup the internal state of the mole, but generally it works like a charm. For example, to replace this c’tor… public class ClassWithCtor {     public int Value { get; private set; }       public ClassWithCtor(int someValue)     {         this.Value = someValue;     } } … you would do the following: [Test, Moled] public void ConstructorTestWithMoles() {     MClassWithCtor.ConstructorInt32 =            ((@class, @value) => new MClassWithCtor(@class) {ValueGet = () => 99});       var classWithCtor = new ClassWithCtor(3);       Assert.AreEqual(99, classWithCtor.Value); } Detouring abstract base classes You can also use this approach to ‘mock’ abstract base classes of a class that you call in your test. Assumed that you have something like that: public abstract class AbstractBaseClass {     public virtual string SaySomething()     {         return "Hello from base.";     } }      public class ChildClass : AbstractBaseClass {     public override string SaySomething()     {         return string.Format(             "Hello from child. Base says: '{0}'",             base.SaySomething());     } } Then you would set up the child’s underlying base class like this: [Test, Moled] public void AbstractBaseClassTestWithMoles() {     ChildClass child = new ChildClass();     new MAbstractBaseClass(child)         {                 SaySomething = () => "Leave me alone!"         }         .InstanceBehavior = MoleBehaviors.Fallthrough;       var hello = child.SaySomething();       Assert.AreEqual("Hello from child. Base says: 'Leave me alone!'", hello); } Setting the moles behavior to a value of  MoleBehaviors.Fallthrough causes the ‘original’ method to be called if a respective delegate is not provided explicitly – here it causes the ChildClass’ override of the SaySomething() method to be called. There are some more possible scenarios, where the Moles framework could be of much help (e.g. it’s also possible to detour interface implementations like IEnumerable<T> and such…). One other possibility that comes to my mind (because I’m currently dealing with that), is to replace calls from repository classes to the ADO.NET Entity Framework O/R mapper with delegates to isolate the repository classes from the underlying database, which otherwise would not be possible… Usage Since Moles relies on runtime instrumentation, mole types must be run under the Pex profiler. This only works from inside Visual Studio if you write your tests with MSTest (Visual Studio Unit Test). While other unit test frameworks generally can be used with Moles, they require the respective tests to be run via command line, executed through the moles.runner.exe tool. A typical test execution would be similar to this: moles.runner.exe <mytests.dll> /runner:<myframework.console.exe> /args:/<myargs> So, the moled test can be run through tools like NCover or a scripting tool like MSBuild (which makes them easy to run in a Continuous Integration environment), but they are somewhat unhandy to run in the usual TDD workflow (which I described in some detail here). To make this a bit more fluent, I wrote a ReSharper live template to generate the respective command line for the test (it is also included in the sample download – moled_cmd.xml). - This is just a quick-and-dirty ‘solution’. Maybe it makes sense to write an extra Gallio adapter plugin (similar to the many others that are already provided) and include it with the Gallio download package, if  there’s sufficient demand for it. As of now, the only way to run tests with the Moles framework from within Visual Studio is by using them with MSTest. From the command line, anything with a managed console runner can be used (provided that the appropriate extension is in place)… A typical Gallio/Moles command line (as generated by the mentioned R#-template) looks like that: "%ProgramFiles%\Microsoft Moles\bin\moles.runner.exe" /runner:"%ProgramFiles%\Gallio\bin\Gallio.Echo.exe" "Gallio.Moles.Demo.dll" /args:/r:IsolatedAppDomain /args:/filter:"ExactType:TestFixture and Member:ReadFileContentWithMoles" -- Note: When using the command line with Echo (Gallio’s console runner), be sure to always include the IsolatedAppDomain option, otherwise the tests won’t use the instrumentation callbacks! -- License issues As I already said, the free mocking frameworks can mock only interfaces and virtual methods. if you want to mock other things, you need the Typemock Isolator tool for that, which comes with license costs (Although these ‘costs’ are ridiculously low compared to the value that such a tool can bring to a software project, spending money often is a considerable gateway hurdle in real life...).  The Moles framework also is not totally free, but comes with the same license conditions as the (closely related) Pex framework: It is free for academic/non-commercial use only, to use it in a ‘real’ software project requires an MSDN Subscription (from VS2010pro on). The demo solution The sample solution (VS 2008) can be downloaded from here. It contains the Gallio.Moles.dll which provides the here described Moled attribute, the above mentioned R#-template (moled_cmd.xml) and a test fixture containing the above described use case scenarios. To run it, you need the Gallio framework (download) and Microsoft Moles (download) being installed in the default locations. Happy testing…

    Read the article

  • Oracle Forms Migration to ADF - Webinar vom ORACLE Partner PITSS

    - by Thomas Leopold
      Tuesday, February 22, 2011 5:00 PM - 6:00 PM CET Free Webinar Re-Engineering Legacy Oracle Forms Migration from Forms to ADF - A Case Study Join Oracle's Grant Ronald and PITSS to see a software architecture comparison of Oracle Forms and ADF and a live step-by-step presentation on how to achieve a successful migration. Learn about various migration options, challenges and best practices to protect your current investment in Oracle Forms. PL/SQL is without match for what it does: manipulating data in the database. If you blindly migrate all your PL/SQL to Java you will, in all probability, end up with less maintainable and less efficient code. Instead you should consider which code it best left as PL/SQL..." Grant Ronald - "Migrating Oracle Forms to Fusion: Myth or Magic Bullet?" Re-Engineering existing business logic is mandatory for your legacy Forms application to take advantage of the new Software architectures like ADF. The PITSS.CON solution combines the deep understanding of Oracle Forms and Reports applications architecture with powerful re-engineering capabilities that allows the developer community to protect the investment in the existing Forms applications and to concentrate on fine-tuning and customization of the modernized functionality rather than manually recreating every module and business logic from bottom up. Registration: https://www2.gotomeeting.com/register/971702250   PITSS GmbHKönigsdorferstrasse 25D-82515 WolfratshausenDo not forget to check out these Free Webinars in March! Thursday, March 3, 2011 Upgrade and Modernize Your Application to Forms 11g Registration/Information Tuesday, March 15, 2011 Shaping the Future for your Oracle Forms Application:Forms 11g, ADF, APEX Registration/Information Tuesday, March 29, 2011 Oracle Forms Modernization to APEX Registration/Information Registration is limited, so sign up  today!Presented By:        Grant Ronald, Senior Group Product Manager,Oracle       Magdalena Serban, Product Manager,PITSS   Contact Us:            PITSS in Americas +1 248.740.0935 [email protected] www.pitssamerica.com       PITSS in Europe +49 (0) 717287 5200 [email protected] www.pitss.com   White Paper:      From Oracle Forms to Oracle ADF and JEE     © Copyright 2010 PITSS GmbH, Wolfratshausen, Stuttgart, München; Managing Directors: Dipl.-Ing. Andreas Gaede, Michael Kilimann, Dipl.-Ing. Dirk Fleischmann Commercial Register: HRB 125471 at District Court Munich. All rights reserved. Any duplication or further treatment in any medium, in parts or as a whole, requires a written agreement. If you do not want to receive invitations for events, meetings and seminars from us, then please click here.

    Read the article

  • How can I find the approximate daily traffic of a site which I don't own?

    - by John Thomas
    I want to find the approximate daily traffic of a site which isn't ours, and the site is located in other country than US (in Greece - hence no Quantcast or Compete.com afaik) and it doesn't use Google Ads (hence no Google Ad Planner). I know about Alexa but the site(s) has/have relatively low traffic and the Alexa's rank isn't very useful (same stands to Google Trends). Or perhaps I should look more at Alexa's data? Any other ideas? PS: I looked before posting here and here. No luck.

    Read the article

  • Another sound not working post

    - by Thomas Smart
    Tried all the other "sound not working" posts i think, lost count. purge/reinstall alsa and pulse, reboot, add user to audio group, various lines in the alsa config file such as "options snd-hda-intel model=" then tried different options like generic, auto, basic, default, etc. tried pulseaudio -k && sudo alsa force-reload a few times, with and without rebooting. Hardware: 16gb ram, core I7-4790, Intel Haswell mboard with onboard sound and graphics Multimedia: Audio Adapter: HDA-Intel-HDA Intel HDMI OS: Ubuntu server 14.04 with ubuntu-desktop installed. GUI sound settings lists only the dummy sound card alsamixer -c 0 ¦ Card: HDA Intel HDMI F1: Help ¦ ¦ Chip: Intel Haswell HDMI F2: System information ¦ ¦ View: F3:[Playback] F4: Capture F5: All F6: Select sound card ¦ ¦ Item: S/PDIF ¦ ¦ +--+ ¦ ¦ ¦OO¦ ¦ ¦ +--+ ¦ ¦ < S/PDIF > ¦ aplay -l **** List of PLAYBACK Hardware Devices **** card 0: HDMI [HDA Intel HDMI], device 3: HDMI 0 [HDMI 0] Subdevices: 1/1 Subdevice #0: subdevice #0 aplay -L default Playback/recording through the PulseAudio sound server null Discard all samples (playback) or generate zero samples (capture) pulse PulseAudio Sound Server hdmi:CARD=HDMI,DEV=0 HDA Intel HDMI, HDMI 0 HDMI Audio Output dmix:CARD=HDMI,DEV=3 HDA Intel HDMI, HDMI 0 Direct sample mixing device dsnoop:CARD=HDMI,DEV=3 HDA Intel HDMI, HDMI 0 Direct sample snooping device hw:CARD=HDMI,DEV=3 HDA Intel HDMI, HDMI 0 Direct hardware device without any conversions plughw:CARD=HDMI,DEV=3 HDA Intel HDMI, HDMI 0 Hardware device with all software conversions cat /proc/asound/cards 0 [HDMI ]: HDA-Intel - HDA Intel HDMI HDA Intel HDMI at 0xf7d14000 irq 46 cat /proc/asound/devices 1: : sequencer 2: [ 0- 3]: digital audio playback 3: [ 0- 0]: hardware dependent 4: [ 0] : control 33: : timer mplayer -ao alsa:device=hdmi /usr/share/sounds/ubuntu/stereo/system-ready.ogg MPlayer 1.1-4.8 (C) 2000-2012 MPlayer Team mplayer: could not connect to socket mplayer: No such file or directory Failed to open LIRC support. You will not be able to use your remote control. Playing /usr/share/sounds/ubuntu/stereo/system-ready.ogg. libavformat version 54.20.4 (external) Mismatching header version 54.20.3 libavformat file format detected. [lavf] stream 0: audio (vorbis), -aid 0 Load subtitles in /usr/share/sounds/ubuntu/stereo/ ========================================================================== Opening audio decoder: [ffmpeg] FFmpeg/libavcodec audio decoders libavcodec version 54.35.0 (external) AUDIO: 44100 Hz, 1 ch, floatle, 80.0 kbit/5.67% (ratio: 10000->176400) Selected audio codec: [ffvorbis] afm: ffmpeg (FFmpeg Vorbis) ========================================================================== [AO_ALSA] alsa-lib: confmisc.c:768:(parse_card) cannot find card '1' [AO_ALSA] alsa-lib: conf.c:4248:(_snd_config_evaluate) function snd_func_card_driver returned error: No such file or directory [AO_ALSA] alsa-lib: confmisc.c:392:(snd_func_concat) error evaluating strings [AO_ALSA] alsa-lib: conf.c:4248:(_snd_config_evaluate) function snd_func_concat returned error: No such file or directory [AO_ALSA] alsa-lib: confmisc.c:1251:(snd_func_refer) error evaluating name [AO_ALSA] alsa-lib: conf.c:4248:(_snd_config_evaluate) function snd_func_refer returned error: No such file or directory [AO_ALSA] alsa-lib: conf.c:4727:(snd_config_expand) Evaluate error: No such file or directory [AO_ALSA] alsa-lib: pcm.c:2239:(snd_pcm_open_noupdate) Unknown PCM hdmi [AO_ALSA] Playback open error: No such file or directory Failed to initialize audio driver 'alsa:device=hdmi' Could not open/initialize audio device -> no sound. Audio: no sound Video: no video Exiting... (End of file) mplayer -ao alsa:device=hw=0.3 /usr/share/sounds/ubuntu/stereo/system-ready.ogg MPlayer 1.1-4.8 (C) 2000-2012 MPlayer Team mplayer: could not connect to socket mplayer: No such file or directory Failed to open LIRC support. You will not be able to use your remote control. Playing /usr/share/sounds/ubuntu/stereo/system-ready.ogg. libavformat version 54.20.4 (external) Mismatching header version 54.20.3 libavformat file format detected. [lavf] stream 0: audio (vorbis), -aid 0 Load subtitles in /usr/share/sounds/ubuntu/stereo/ ========================================================================== Opening audio decoder: [ffmpeg] FFmpeg/libavcodec audio decoders libavcodec version 54.35.0 (external) AUDIO: 44100 Hz, 1 ch, floatle, 80.0 kbit/5.67% (ratio: 10000->176400) Selected audio codec: [ffvorbis] afm: ffmpeg (FFmpeg Vorbis) ========================================================================== [AO_ALSA] Format floatle is not supported by hardware, trying default. AO: [alsa] 44100Hz 2ch s16le (2 bytes per sample) Video: no video Starting playback... A: 0.4 (00.4) of 0.8 (00.7) 0.1% Exiting... (End of file) Thank you for your time and help :)

    Read the article

  • Handling Trailing Delimiters in HL7 Messages

    - by Thomas Canter
    Applies to: BizTalk Server 2006 with the HL7 1.3 Accelerator Outline of the problem Trailing Delimiters are empty values at the end of an object in a HL7 ER7 formatted message. Examples: Empty Field NTE|P| NTE|P|| Empty component ORC|1|725^ Empty Subcomponent ORC|1|||||27& Empty repeat OBR|1||||||||027~ Trailing delimiters indicate the following object exists and is empty, which is quite different from null, null is an explicit value indicated by a pair of double quotes -> "". The BizTalk HL7 Accelerator by default does not allow trailing delimiters. There are three methods to allow trailing delimiters. NOTE: All Schemas always allow trailing delimiters in the MSH Segment Using party identifiers MSH3.1 – Receive/inbound processing, using this value as a party allows you to configure the system to allow inbound trailing delimiters. MSH5.1 – Send/outbound processing, using this value as a party allows you to configure the system to allow outbound trailing delimiters. Generally, if you allow inbound trailing delimiters, unless you are willing to programmatically remove all trailing delimiters, then you need to configure the send to allow trailing delimiters. Add the appropriate parties to the BizTalk Parties list from these two fields in your message stream. Open the BizTalk HL7 Configuration tool and for each party check the "Allow trailing delimiters (separators)" check box on the Validation tab. Disadvantage – Each MSH3.1 and MSH5.1 value must be represented in the parties list and configured. Advantage – granular control over system behavior for each inbound/outbound system. Using instance properties of a pipeline used in a send port or receive location. Open the BizTalk Server Administration console locate the send port or receive location that contains the BTAHL72XReceivePipeline or BTAHL72XSendPipeline pipeline. Open the properties To the right of the pipeline selected locate the […] ellipses button In the property list, locate the "TrailingDelimiterAllowed" property and set it to True. Advantage – All messages through a particular Send Port or Receive Location will allow trailing delimiters. Disadvantage – Must configure each Send Port or Receive Location. No granular control over which remote parties will send or receive messages with trailing delimiters. Using a custom pipeline that uses a pre-configured BTA HL7 Pipeline component. Use Visual Studio to construct a custom receive and send pipeline using the appropriate assembler or dissasembler. Set the component property to "TrailingDelimitersAllowed" to True Compile and deploy the custom pipeline Use the custom pipeline instead of the standard pipeline for all HL7 message processing Advantage – All messages using the custom pipeline will automatically allow trailing delimiters. Disadvantage – Requires custom coding and development to create and deploy the custom pipeline. No granular control over which remote parties will send or receive messages with trailing delimiters. What does a Trailing Delimiter do to the XML Schema? Allowing trailing delimiters does not have the impact often expected in the actual XML Schema.The Schema reproduces the message with no data loss.Thus, the message when represented in XML must contain the extra fields, in order to reproduce the outbound message.Thus, a trialing delimiter results in an empty XML field.Trailing Delmiters are not stripped from the inbound message. Example:<PID_21>44172</PID_21><PID_21>9257</PID_21> -> the original maximum number of repeats<PID_21></PID_21> -> The empty repeated field Allowing trailing delimiters not remove the trailing delimiters from the message, it simply suppresses the check that will cause the message to fail parse with trailing delimiters. When can you not fix the problem by enabling trailing delimiters Each object in a message must have a location in the target BTAHL7 schema for its content to reside.If you have more objects in the message than are contained at that location, then enabling trailing delimiters will not resolve the problem. The schema must be extended to accommodate the empty message content.Examples: Extra Field NTE|P||||Only 4 fields in NTE Segment, the 4th field exists, but is empty. Extra component PID|1|1523|47^^^^^^^Only 5 components in a CX data type, the 5th component exists, but is empty Extra subcomponent ORC|1|||||27&&Only 2 subcomponents in a CQ data type, the 3rd subcomponent is empty, but exists. Extra Repeat PID|1||||||||||||||||||||4419~5217~Only 2 repeats allowed for the field "Mother's identifier", the repeat is empty, but exists. In each of these cases, you must locate the failing object and extend the type to allow an additional object of that type. FieldAdd a field of ST to the end of the segment with a suitable name in the segments_nnn.xsd Component Create a new Custom CX data type (i.e. CX_XtraComp) in the datatypes_nnn.xsd and add a new component to the custom CX data type. Update the field in the segments_nnn.xsd file to use the custom data type instead of the standard datatype. Subcomponent Create a new Custom CQ data type that accepts an additional TS value at the end of the data type. Create a custom TQ data type that uses the new custom CQ data type as the first subcomponent. Modify the ORC segment to use the new CQ data type at ORC.7 instead of the standard CQ data type. RepeatModify the Field definition for PID.21 in the segments_nnn.xsd to allow more repeats in the field.

    Read the article

  • Database continuous integration step by step

    - by David Atkinson
    This post will describe how to set up basic database continuous integration using TeamCity to initiate the build process, SQL Source Control to put your database under source control, and the SQL Compare command line to keep a test database up to date. In my example I will be using Subversion as my source control repository. If you wish to follow my steps verbatim, please make sure you have TortoiseSVN, SQL Compare and SQL Source Control installed. Downloading and Installing TeamCity TeamCity (http://www.jetbrains.com/teamcity/index.html) is free for up to three agents, so it a great no-risk tool you can use to experiment with. 1. Download the latest version from the JetBrains website. For some reason the TeamCity executable didn't download properly for me, stalling frustratingly at 99%, so I tried again with the zip file download option (see screenshot below), which worked flawlessly. 2. Run the installer using the defaults. This results in a set-up with the server component and agent installed on the same machine, which is ideal for getting started with ease. 3. Check that the build agent is pointing to the server correctly. This has caught me out a few times before. This setting is in C:\TeamCity\buildAgent\conf\buildAgent.properties and for my installation is serverUrl=http\://localhost\:80 . If you need to change this value, if for example you've had to install the Server console to a different port number, the TeamCity Build Agent Service will need to be restarted for the change to take effect. 4. Open the TeamCity admin console on http://localhost , and specify your own designated username and password at first startup. Putting your database in source control using SQL Source Control 5. Assuming you've got SQL Source Control installed, select a development database in the SQL Server Management Studio Object Explorer and select Link Database to Source Control. 6. For the Link step you can either create your own empty folder in source control, or you can select Just Evaluating, which just creates a local subversion repository for you behind the scenes. 7. Once linked, note that your database turns green in the Object Explorer. Visit the Commit tab to do an initial commit of your database objects by typing in an appropriate comment and clicking Commit. 8. There is a hidden feature in SQL Source Control that opens up TortoiseSVN (provided it is installed) pointing to the linked repository. Keep Shift depressed and right click on the text to the right of 'Linked to', in the example below, it's the red Evaluation Repository text. Select Open TortoiseSVN Repo Browser. This screen should give you an idea of how SQL Source Control manages the object files behind the scenes. Back in the TeamCity admin console, we'll now create a new project to monitor the above repository location and to trigger a 'build' each time the repository changes. 9. In TeamCity Adminstration, select Create Project and give it a name, such as "My first database CI", and click Create. 10. Click on Create Build Configuration, and name it something like "Integration build". 11. Click VCS settings and then Create And Attach new VCS root. This is where you will tell TeamCity about the repository it should monitor. 12. In my case since I'm using the Just Evaluating option in SQL Source Control, I should select Subversion. 13. In the URL field paste your repository location. In my case this is file:///C:/Users/David.Atkinson/AppData/Local/Red Gate/SQL Source Control 3/EvaluationRepositories/WidgetDevelopment/WidgetDevelopment 14. Click on Test Connection to ensure that you can communicate with your source control system. Click Save. 15. Click Add Build Step, and Runner Type: Command Line. Should you be familiar with the other runner types, such as NAnt, MSBuild or Powershell, you can opt for these, but for the same of keeping it simple I will pick the simplest option. 16. If you have installed SQL Compare in the default location, set the Command Executable field to: C:\Program Files (x86)\Red Gate\SQL Compare 10\sqlcompare.exe 17. Flip back to SSMS briefly and add a new database to your server. This will be the database used for continuous integration testing. 18. Set the command parameters according to your server and the name of the database you have created. In my case I created database RedGateCI on server .\sql2008r2 /scripts1:. /server2:.\sql2008r2 /db2:RedGateCI /sync /verbose Note that if you pick a server instance that isn't on your local machine, you'll need the TCP/IP protocol enabled in SQL Server Configuration Manager otherwise the SQL Compare command line will not be able to connect. 19. Save and select Build Triggering / Add New Trigger / VCS Trigger. This is where you tell TeamCity when it should initiate a build. Click Save. 20. Now return to SQL Server Management Studio and make a schema change (eg add a new object) to your linked development database. A blue indicator will appear in the Object Explorer. Commit this change, typing in an appropriate check-in comment. All being good, within 60 seconds (a TeamCity default that can be changed) a build will be triggered. 21. Click on Projects in TeamCity to get back to the overview screen: The build log will show you the console output, which is useful for troubleshooting any issues: That's it! You now have continuous integration on your database. In future posts I'll cover how you can generate and test the database creation script, the database upgrade script, and run database unit tests as part of your continuous integration script. If you have any trouble getting this up and running please let me know, either by commenting on this post, or email me directly using the email address below. Technorati Tags: SQL Server

    Read the article

  • Hosting a website on Heroku.... I know how to, but im running into problems!

    - by Thomas Miller
    I'm starting to learn more on the back-end scale of programing. Recently I started up Heroku for the second or third time. This time I actually installed the Git update to my Mac and installed Heroku in the terminal. I wanted to upload a static html site with the Sinatra gem. Everything worked out fine inside the terminal, though I added Sinatra after I got everything working and the file with the site hooked up to Heroku. In my logs I did see that I was missing the Sinatra gem, so I installed it. My site contains both the proper app.rb and config.ru files. I have nothing showing up online. Just a blank screen! Contacting Heroku on this problem has been very difficult. I get a response every day, and on every day I respond with a question to the answer that didn't help me at all. 2011-05-18T00:25:20+00:00 app[web.1]: 71.198.0.51 - - [17/May/2011 17:25:20] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T00:25:20+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=2ms bytes=313 2011-05-18T00:25:26+00:00 app[web.1]: 71.198.0.51 - - [17/May/2011 17:25:26] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T00:25:26+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=5ms bytes=313 2011-05-17T18:25:51-07:00 heroku[web.1]: Idling 2011-05-17T18:26:01-07:00 heroku[web.1]: State changed from up to down 2011-05-18T01:26:01+00:00 heroku[web.1]: Stopping process with SIGTERM 2011-05-18T01:26:01+00:00 app[web.1]: >> Stopping ... 2011-05-18T01:26:02+00:00 heroku[web.1]: Process exited 2011-05-17T20:12:46-07:00 heroku[web.1]: Unidling 2011-05-17T20:12:47-07:00 heroku[web.1]: State changed from created to starting 2011-05-18T03:12:48+00:00 heroku[web.1]: Starting process with command: `thin -p 40055 -e production -R /home/heroku_rack/heroku.ru start` 2011-05-18T03:12:49+00:00 app[web.1]: >> Thin web server (v1.2.6 codename Crazy Delicious) 2011-05-18T03:12:49+00:00 app[web.1]: >> Maximum connections set to 1024 2011-05-18T03:12:49+00:00 app[web.1]: >> Listening on 0.0.0.0:40055, CTRL+C to stop 2011-05-18T03:12:50+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=9954ms service=6ms bytes=565 2011-05-18T03:12:50+00:00 app[web.1]: 70.91.206.114 - - [17/May/2011 20:12:50] "GET /style.css HTTP/1.1" 200 - 0.0012 2011-05-18T03:12:50+00:00 heroku[router]: GET pxlc.heroku.com/style.css dyno=web.1 queue=0 wait=0ms service=2ms bytes=269 2011-05-17T20:12:50-07:00 heroku[web.1]: State changed from starting to up 2011-05-18T03:12:51+00:00 app[web.1]: 70.91.206.114 - - [17/May/2011 20:12:51] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T03:12:51+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=4ms bytes=313 2011-05-18T03:13:05+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=0ms service=5ms bytes=565 2011-05-18T03:13:05+00:00 app[web.1]: 70.91.206.114 - - [17/May/2011 20:13:05] "GET / HTTP/1.1" 200 293 0.0011 2011-05-18T03:13:05+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=2ms bytes=313 2011-05-18T03:13:05+00:00 app[web.1]: 70.91.206.114 - - [17/May/2011 20:13:05] "GET /favicon.ico HTTP/1.1" 404 18 0.0007 2011-05-18T03:57:05+00:00 app[web.1]: 172.18.33.56, 58.96.134.66 - - [17/May/2011 20:57:05] "GET / HTTP/1.1" 200 293 0.0007 2011-05-18T03:57:05+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=0ms service=4ms bytes=565 2011-05-18T03:57:05+00:00 app[web.1]: 172.18.33.56, 58.96.134.66 - - [17/May/2011 20:57:05] "GET /style.css HTTP/1.1" 200 - 0.0007 2011-05-18T03:57:05+00:00 heroku[router]: GET pxlc.heroku.com/style.css dyno=web.1 queue=0 wait=0ms service=2ms bytes=269 2011-05-18T03:57:08+00:00 app[web.1]: 172.18.33.56, 58.96.134.66 - - [17/May/2011 20:57:08] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-17T21:58:27-07:00 heroku[web.1]: Idling 2011-05-18T04:58:30+00:00 heroku[web.1]: Stopping process with SIGTERM 2011-05-18T04:58:30+00:00 app[web.1]: >> Stopping ... 2011-05-18T04:58:30+00:00 heroku[web.1]: Process exited 2011-05-17T21:58:33-07:00 heroku[web.1]: State changed from up to down 2011-05-17T23:11:58-07:00 heroku[web.1]: Unidling 2011-05-17T23:11:58-07:00 heroku[web.1]: State changed from created to starting 2011-05-18T06:12:00+00:00 heroku[web.1]: Starting process with command: `thin -p 40091 -e production -R /home/heroku_rack/heroku.ru start` 2011-05-18T06:12:01+00:00 app[web.1]: >> Thin web server (v1.2.6 codename Crazy Delicious) 2011-05-18T06:12:01+00:00 app[web.1]: >> Maximum connections set to 1024 2011-05-18T06:12:01+00:00 app[web.1]: >> Listening on 0.0.0.0:40091, CTRL+C to stop 2011-05-18T06:12:01+00:00 app[web.1]: 183.97.156.226 - - [17/May/2011 23:12:01] "GET / HTTP/1.1" 200 293 0.0017 2011-05-18T06:12:02+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=3209ms service=5ms bytes=565 2011-05-18T06:12:03+00:00 app[web.1]: 183.97.156.226 - - [17/May/2011 23:12:03] "GET /style.css HTTP/1.1" 200 - 0.0019 2011-05-17T23:12:08-07:00 heroku[web.1]: State changed from starting to up 2011-05-18T00:13:13-07:00 heroku[web.1]: Idling 2011-05-18T00:13:16-07:00 heroku[web.1]: State changed from up to down 2011-05-18T07:13:16+00:00 heroku[web.1]: Stopping process with SIGTERM 2011-05-18T07:13:16+00:00 app[web.1]: >> Stopping ... 2011-05-18T07:13:17+00:00 heroku[web.1]: Process exited 2011-05-18T01:54:21-07:00 heroku[web.1]: Unidling 2011-05-18T01:54:21-07:00 heroku[web.1]: State changed from created to starting 2011-05-18T08:54:23+00:00 heroku[web.1]: Starting process with command: `thin -p 59491 -e production -R /home/heroku_rack/heroku.ru start` 2011-05-18T08:54:24+00:00 app[web.1]: >> Thin web server (v1.2.6 codename Crazy Delicious) 2011-05-18T08:54:24+00:00 app[web.1]: >> Maximum connections set to 1024 2011-05-18T08:54:24+00:00 app[web.1]: >> Listening on 0.0.0.0:59491, CTRL+C to stop 2011-05-18T01:54:28-07:00 heroku[web.1]: State changed from starting to up 2011-05-18T08:54:28+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=6943ms service=6ms bytes=565 2011-05-18T08:54:28+00:00 app[web.1]: 62.244.82.72 - - [18/May/2011 01:54:28] "GET / HTTP/1.1" 200 293 0.0018 2011-05-18T08:54:28+00:00 heroku[router]: GET pxlc.heroku.com/style.css dyno=web.1 queue=0 wait=0ms service=2ms bytes=269 2011-05-18T08:54:28+00:00 app[web.1]: 62.244.82.72 - - [18/May/2011 01:54:28] "GET /style.css HTTP/1.1" 200 - 0.0014 2011-05-18T08:54:28+00:00 app[web.1]: 62.244.82.72 - - [18/May/2011 01:54:28] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T08:54:28+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=1ms bytes=313 2011-05-18T08:54:28+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=4ms bytes=313 2011-05-18T08:54:28+00:00 app[web.1]: 62.244.82.72 - - [18/May/2011 01:54:28] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T08:54:28+00:00 app[web.1]: 62.244.82.72 - - [18/May/2011 01:54:28] "GET /favicon.ico HTTP/1.1" 404 18 0.0008 2011-05-18T08:54:28+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=1ms bytes=313 2011-05-18T02:55:23-07:00 heroku[web.1]: Idling 2011-05-18T02:55:33-07:00 heroku[web.1]: State changed from up to down 2011-05-18T09:55:34+00:00 heroku[web.1]: Stopping process with SIGTERM 2011-05-18T09:55:34+00:00 app[web.1]: >> Stopping ... 2011-05-18T09:55:34+00:00 heroku[web.1]: Process exited 2011-05-18T07:23:10-07:00 heroku[web.1]: State changed from created to starting 2011-05-18T14:23:12+00:00 heroku[web.1]: Starting process with command: `thin -p 20560 -e production -R /home/heroku_rack/heroku.ru start` 2011-05-18T14:23:13+00:00 app[web.1]: >> Thin web server (v1.2.6 codename Crazy Delicious) 2011-05-18T14:23:13+00:00 app[web.1]: >> Maximum connections set to 1024 2011-05-18T14:23:13+00:00 app[web.1]: >> Listening on 0.0.0.0:20560, CTRL+C to stop 2011-05-18T07:23:13-07:00 heroku[web.1]: State changed from starting to up 2011-05-18T14:23:14+00:00 app[web.1]: 12.183.19.10 - - [18/May/2011 07:23:14] "GET / HTTP/1.1" 200 293 0.0018 2011-05-18T14:23:14+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=0ms service=7ms bytes=565 2011-05-18T14:23:14+00:00 app[web.1]: 12.183.19.10 - - [18/May/2011 07:23:14] "GET /style.css HTTP/1.1" 200 - 0.0015 2011-05-18T14:23:14+00:00 heroku[router]: GET pxlc.heroku.com/style.css dyno=web.1 queue=0 wait=0ms service=2ms bytes=269 2011-05-18T14:23:14+00:00 app[web.1]: 12.183.19.10 - - [18/May/2011 07:23:14] "GET /favicon.ico HTTP/1.1" 404 18 0.0009 2011-05-18T14:23:14+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=2ms bytes=313 2011-05-18T08:24:03-07:00 heroku[web.1]: Idling 2011-05-18T08:24:07-07:00 heroku[web.1]: State changed from up to down 2011-05-18T15:24:07+00:00 heroku[web.1]: Stopping process with SIGTERM 2011-05-18T15:24:07+00:00 app[web.1]: >> Stopping ... 2011-05-18T17:34:27-07:00 heroku[web.1]: Unidling 2011-05-18T17:34:28-07:00 heroku[web.1]: State changed from created to starting 2011-05-19T00:34:29+00:00 heroku[web.1]: Starting process with command: `thin -p 57621 -e production -R /home/heroku_rack/heroku.ru start` 2011-05-18T17:34:31-07:00 heroku[web.1]: State changed from starting to up 2011-05-19T00:34:32+00:00 heroku[router]: GET pxlc.heroku.com/ dyno=web.1 queue=0 wait=0ms service=5ms bytes=565 2011-05-19T00:34:32+00:00 app[web.1]: 97.83.58.74 - - [18/May/2011 17:34:32] "GET / HTTP/1.1" 200 293 0.0016 2011-05-19T00:34:32+00:00 app[web.1]: 97.83.58.74 - - [18/May/2011 17:34:32] "GET /style.css HTTP/1.1" 200 - 0.0011 2011-05-19T00:34:32+00:00 heroku[router]: GET pxlc.heroku.com/style.css dyno=web.1 queue=0 wait=0ms service=2ms bytes=269 2011-05-19T00:34:34+00:00 heroku[router]: GET pxlc.heroku.com/favicon.ico dyno=web.1 queue=0 wait=0ms service=4ms bytes=313 2011-05-19T00:34:34+00:00 app[web.1]: 97.83.58.74 - - [18/May/2011 17:34:34] "GET /favicon.ico HTTP/1.1" 404 18 0.0007 2011-05-18T18:35:48-07:00 heroku[web.1]: Idling 2011-05-18T18:35:51-07:00 heroku[web.1]: State changed from up to down

    Read the article

  • Stage3D Camera problem

    - by Thomas Versteeg
    I am trying to create a 2D Stage3D game where you can move the camera around the level in an RTS style. I thought about using Orthographic Matrix3D functions for this but when I try to scroll the whole "stage" also scrolls. This is the Camera code: public function Camera2D(width:int, height:int, zoom:Number = 1) { resize(width, height); _zoom = zoom; } public function resize(width:Number, height:Number):void { _width = width; _height = height; _projectionMatrix = makeMatrix(0, width, 0, height); _recalculate = true; } protected function makeMatrix(left:Number, right:Number, top:Number, bottom:Number, zNear:Number = 0, zFar:Number = 1):Matrix3D { return new Matrix3D(Vector.<Number>([ 2 / (right - left), 0, 0, 0, 0, 2 / (top - bottom), 0, 0, 0, 0, 1 / (zFar - zNear), 0, 0, 0, zNear / (zNear - zFar), 1 ])); } public function get viewMatrix():Matrix3D { if (_recalculate) { _recalculate = false; _viewMatrix.identity(); _viewMatrix.appendTranslation( -_width / 2 - _x, -_height / 2 - y, 0); _viewMatrix.appendScale(_zoom, _zoom, 1); _renderMatrix.identity(); _renderMatrix.append(_viewMatrix); _renderMatrix.append(_projectionMatrix); } return _renderMatrix; } Here are two screenshots to show what I mean: How do I only let the inside of the stage3D scroll and not the whole stage?

    Read the article

  • Lenovo DVD Drive Disabled After Windows 7 Install

    - by David Lacher
    Upgraded hard drive in Lenovo T61P; decided to start fresh with Windows 7 Pro. Windows installed, so DVD drive was working. All of a sudden, driver is not recognized. Device is "HL-DT-ST DVDRAM GSA-U10N ATA Device". It appears on device manager but with the yellow tag; have tried uninstalling, searching for drivers, everything I can think of. Cannot even start over with Windows 7 installation disk because disk spins but then stops and My Computer does not recognize the drive. Help please. thank you. David Lacher

    Read the article

  • Should I be wary of signing a non-disclosure agreement with someone I just met?

    - by Thomas Levine
    tl;dr: Some guy I just met says he wants me to join his company. Before he shows me what they do, he wants me to sign a non-disclosure agreement. Is this weird? I'm traveling right now. Someone who saw me coding seemed to think I was smart or something and started talking with me. He explained that he owns a software company, told me a bit about what it does and told me that he was looking for a programmer who would work for a stake in the company. He explained that the company's product is being developed rather secretly, so he couldn't tell me much. But he did tell enough about the product to convince me that he's not completely making this up, which is a decent baseline. He suggested that he show me more of what he's been working on and, after seeing that, I decide whether I want to join. Because of the secrecy behind the product, he wants me to sign a non-disclosure agreement before we talk. I'm obviously somewhat skeptical because of the random nature by which we met. In the short term, I'm wondering if I should be wary of signing such an agreement. He said it would be easier to show me the product in person rather than over the internet, and I'm leaving town tomorrow, so I'd have to figure this out by tomorrow. If I decide to talk with him, I could decide later whether I trust that it's worth spending any time on this company. The concept of being able to avoid telling a secret seems strange to me for the same reason that things like certain aspects of copyright seem strange. Should I be wary of signing a non-disclosure agreement? Is this common practice? I don't know the details of the agreement of which he was thinking, (If I end up meeting with him, I'll of course read over the agreement before I decide whether to sign it.) so I could consider alternatives according to the aspects of the agreement. Or I could just consider the case of an especially harsh agreement. This question seems vaguely related. Do we need a non-disclosure agreement (NDA)? Thanks

    Read the article

  • Lenovo DVD Drive Disabled After Windows 7 Install

    - by David Lacher
    Upgraded hard drive in Lenovo T61P; decided to start fresh with Windows 7 Pro. Windows installed, so DVD drive was working. All of a sudden, driver is not recognized. Device is "HL-DT-ST DVDRAM GSA-U10N ATA Device". It appears on device manager but with the yellow tag; have tried uninstalling, searching for drivers, everything I can think of. Cannot even start over with Windows 7 installation disk because disk spins but then stops and My Computer does not recognize the drive. Help please. thank you. David Lacher

    Read the article

  • ORACLE Forms Upgrade Workshops

    - by Thomas Leopold
       09. Februar 2011 Workshop: Forms Upgrade von 10g (iAS) nach 11g (WLS) Oracle Deutschland lädt Sie zu einem Workshop zum Thema Forms Upgrade von 10g (iAS) nach 11g (WLS) ein. Der Workshop ist für Entwickler und Administratoren gedacht, die sich einen Überblick über die Änderungen verschaffen möchten, die sich aus der Migration von 10g auf 11g ergeben. Der Wokshop gibt einen Überblick über die architekturellen Unterschiede zwischen dem Internet Application Server und dem WebLogic Server. Er erläutert die für den Betrieb von Forms-Anwendungen relevanten Unterschiede und Gemeinsamkeiten beider Ansätze. Im HandsOn-Teil migrieren die Teilnehmer selbst einige (exemplarische) Forms-Anwendungen von 10g nach 11g und konfigurieren den WLS zum Betrieb der Forms-Module.   Agenda Beginn: 10:00 Uhr Architektur des WebLogicServers, Unterschiede 10g (iAS) und 11g (WLS) Forms unter WebLogicServer 11g Forms 11g - New Features Administration von Formsanwendungen unter 11g HandsOn: Migration von Forms-Beispielanwendungen Ende: 16:00 Uhr Termine 30. März 2011 - Potsdam | Registrieren 31. März 2011 - Hamburg | Registrieren Technische Voraussetzungen Zur Nutzung des Migrationsassistenten unter 11g müssen die Installationen 10g (iAS) und 11g (WLS) auf einem Server parallel betrieben werden. Dazu ist ein Rechner mit mindestens 4 GB RAM erforderlich; die entsprechenden Installationen werden als virtuelle Maschine zur Verfügung gestellt. Sofern Sie über keinen ausreichend dimensionierten Laptop verfügen, können wir Ihnen für den Workshop ein entsprechendes Gerät ausleihen. Bitte geben Sie dies bei der Anmeldung an, da wir nur über eine begrenzte Anzahl von Leihlaptops verfügen. Wenn Sie den Workshop auf Ihrem Laptop durchführen möchten, beachten Sie bitte die folgenden Systemvoraussetzungen 4 GB RAM Oracle VirtualBox (4.0.2) (incl. GuestAdditions) Anmeldung Zur Anmeldung nutzen Sie bitte die o.a. Links. Der Workshop ist für die Teilnehmer kostenlos. Bei Fragen oder Anmerkungen wenden Sie sich bitte an Christian Kühne (0511-95787-143)ORACLE Deutschland B.V. & Co. KGThurnithistrasse 2-630519 Hannover oder Wolfgang Kriebel (0331 2007 295) ORACLE Deutschland B.V. & Co. KGSchiffbauergasse 1414467 Potsdam ORACLE Deutschland B.V. & Co. KG, Hauptverwaltung: Riesstraße 25, D-80992 München Registergericht: Amtsgericht München, HRA 95603 Komplementärin ORACLE Deutschland Verwaltung B.V. Rijnzathe 6, 3454PV De Meern, Niederlande Handelsregister der Handelskammer Midden-Niederlande, Nr. 30143697 Geschäftsführer: Jürgen Kunz, Marcel van de Molen, Alexander van der Ven  

    Read the article

  • Master Data Management and Cloud Computing

    - by david.butler(at)oracle.com
    Cloud Computing is all the rage these days. There are many reasons why this is so. But like its predecessor, Service Oriented Architecture, it can fall on hard times if the underlying data is left unmanaged. Master Data Management is the perfect Cloud companion. It can materially increase the chances for successful Cloud initiatives. In this blog, I'll review the nature of the Cloud and show how MDM fits in.   Here's the National Institute of Standards and Technology Cloud definition: •          Cloud computing is a model for enabling convenient, on-demand network access to a shared pool of configurable computing resources that can be rapidly provisioned and released with minimal management effort or service provider interaction.   Cloud architectures have three main layers: applications or Software as a Service (SaaS), Platforms as a Service (PaaS), and Infrastructure as a Service (IaaS). SaaS generally refers to applications that are delivered to end-users over the Internet. Oracle CRM On Demand is an example of a SaaS application. Today there are hundreds of SaaS providers covering a wide variety of applications including Salesforce.com, Workday, and Netsuite. Oracle MDM applications are located in this layer of Oracle's On Demand enterprise Cloud platform. We call it Master Data as a Service (MDaaS). PaaS generally refers to an application deployment platform delivered as a service. They are often built on a grid computing architecture and include database and middleware. Oracle Fusion Middleware is in this category and includes the SOA and Data Integration products used to connect SaaS applications including MDM. Finally, IaaS generally refers to computing hardware (servers, storage and network) delivered as a service.  This typically includes the associated software as well: operating systems, virtualization, clustering, etc.    Cloud Computing benefits are compelling for a large number of organizations. These include significant cost savings, increased flexibility, and fast deployments. Cost advantages include paying for just what you use. This is especially critical for organizations with variable or seasonal usage. Companies don't have to invest to support peak computing periods. Costs are also more predictable and controllable. Increased agility includes access to the latest technology and experts without making significant up front investments.   While Cloud Computing is certainly very alluring with a clear value proposition, it is not without its challenges. An IDC survey of 244 IT executives/CIOs and their line-of-business (LOB) colleagues identified a number of issues:   Security - 74% identified security as an issue involving data privacy and resource access control. Integration - 61% found that it is hard to integrate Cloud Apps with in-house applications. Operational Costs - 50% are worried that On Demand will actually cost more given the impact of poor data quality on the rest of the enterprise. Compliance - 49% felt that compliance with required regulatory, legal and general industry requirements (such as PCI, HIPAA and Sarbanes-Oxley) would be a major issue. When control is lost, the ability of a provider to directly manage how and where data is deployed, used and destroyed is negatively impacted.  There are others, but I singled out these four top issues because Master Data Management, properly incorporated into a Cloud Computing infrastructure, can significantly ameliorate all of these problems. Cloud Computing can literally rain raw data across the enterprise.   According to fellow blogger, Mike Ferguson, "the fracturing of data caused by the adoption of cloud computing raises the importance of MDM in keeping disparate data synchronized."   David Linthicum, CTO Blue Mountain Labs blogs that "the lack of MDM will become more of an issue as cloud computing rises. We're moving from complex federated on-premise systems, to complex federated on-premise and cloud-delivered systems."    Left unmanaged, non-standard, inconsistent, ungoverned data with questionable quality can pollute analytical systems, increase operational costs, and reduce the ROI in Cloud and On-Premise applications. As cloud computing becomes more relevant, and more data, applications, services, and processes are moved out to cloud computing platforms, the need for MDM becomes ever more important. Oracle's MDM suite is designed to deal with all four of the above Cloud issues listed in the IDC survey.   Security - MDM manages all master data attribute privacy and resource access control issues. Integration - MDM pre-integrates Cloud Apps with each other and with On Premise applications at the data level. Operational Costs - MDM significantly reduces operational costs by increasing data quality, thereby improving enterprise business processes efficiency. Compliance - MDM, with its built in Data Governance capabilities, insures that the data is governed according to organizational standards. This facilitates rapid and accurate reporting for compliance purposes. Oracle MDM creates governed high quality master data. A unified cleansed and standardized data view is produced. The Oracle Customer Hub creates a single view of the customer. The Oracle Product Hub creates high quality product data designed to support all go-to-market processes. Oracle Supplier Hub dramatically reduces the chances of 'supplier exceptions'. Oracle Site Hub masters locations. And Oracle Hyperion Data Relationship Management masters financial reference data and manages enterprise hierarchies across operational areas from ERP to EPM and CRM to SCM. Oracle Fusion Middleware connects Cloud and On Premise applications to MDM Hubs and brings high quality master data to your enterprise business processes.   An independent analyst once said "Poor data quality is like dirt on the windshield. You may be able to drive for a long time with slowly degrading vision, but at some point, you either have to stop and clear the windshield or risk everything."  Cloud Computing has the potential to significantly degrade data quality across the enterprise over time. Deploying a Master Data Management solution prior to or in conjunction with a move to the Cloud can insure that the data flowing into the enterprise from the Cloud is clean and governed. This will in turn insure that expected returns on the investment in Cloud Computing will be realized.       Oracle MDM has proven its metal in this area and has the customers to back that up. In fact, I will be hosting a webcast on Tuesday, April 10th at 10 am PT with one of our top Cloud customers, the Church Pension Group. They have moved all mainline applications to a hosted model and use Oracle MDM to insure the master data is managed and cleansed before it is propagated to other cloud and internal systems. I invite you join Martin Hossfeld, VP, IT Operations, and Danette Patterson, Enterprise Data Manager as they review business drivers for MDM and hosted applications, how they did it, the benefits achieved, and lessons learned. You can register for this free webcast here.  Hope to see you there.

    Read the article

  • Which comes first DNS or name servers?

    - by Thomas Clayson
    Which comes first? DNS or nameservers? Its just I'm editing a domain and want to point it to different hosting servers. Now, normally I'd just set the nameservers to the new hosting nameservers, but this doesn't seem to be working (the control panels not brilliant - doesn't say "accepted" or "success" - and whois searches are turning up nothing - although I should leave it a while longer). Anyway - the point is, in the DNS records there are two A records (one for " " and one for "www") which have an ip address associated with them. So this is what I don't understand. If I change the nameservers, do I have to remove the DNS records? Will name servers "overwrite" a DNS record? Or vice versa? Thank you.

    Read the article

  • What is the difference between DLNA and UPNP ?

    - by David Michel
    Hi All, Can someone tell me the what is the difference between DLNA and UPNP ? I can see that some devices such as NAS have their specifications mentioning both (e.g. Iomega StorCenter) or only DLNA (e.g. Netgear Stora). Is this a synomym for the same thing or is is actually 2 different protocals ? Are they compatible, i.e. if a media server uses DLNA and the streaming device uses UPNP, will it work ? I looked around but could not find any clear answer... Many thanks David

    Read the article

  • Windows 8: Everything from design, build, and how to sell a Metro style app

    - by Thomas Mason
    For me, there are a lot of similarities between an application developed for Windows Phone and a Metro style app developed for Windows 8. A Windows Phone 7 application (rather than an XNA game) is built in .NET and XAML against a subset of the .NET framework and the application has a lifecycle which needs to be conscious of battery life and so is split out into foreground/background pieces. The application is sandboxed in terms of its interactions with the local device and is packaged with a manifest which describes those interactions. The app needs to be aware of network connectivity status and its work on the network is done asynchronously to preserve the user experience.The app is packaged and deployed to a Marketplace which the user browses to find the app, read reviews, perhaps purchase it and then install it and receive updates over time. Quite a lot of those statements are as true of a Windows 8 Metro style app as they are for a Windows Phone app and so a Windows Phone app developer already has a good head start when it comes to building Metro style apps for Windows 8. With that in mind, there is an event to help developers with a Windows Phone app in Marketplace to begin the process of looking at Windows 8 and whether you can get a quick win by bringing your Phone application onto Windows. The idea of the event was to provide a space where developers can get together over 2 days and take the time out to look at what it means to take their app from Windows Phone to Windows 8. Kicking off on Saturday 16th June at 10am, we are told they have plenty of power sockets, WiFi, whiteboards, drinks, pizza, games, prizes and some quiet space that you can work in. Including people on hand with Windows Phone and Windows 8 experience to help everything along the way. There will be an attendee-voted schedule of talks but we’ll keep these out of your way if you just want to get on and code. We’ll also provide information around submitting your app to the Windows Store If you have a Windows Phone app in Marketplace, now’s a great time to look at getting it onto Windows 8. Sign up. Bring your laptop. Bring your app. Bring Windows 8 and Visual Studio 11. And everyone will their best to help you get your app onto Windows 8. Location & Venue TBA but it will be in central London, accessible by major railway and underground transportation. Day 1 Saturday 16th June 10am – 9pm Day 2 Sunday 17th June 10am – 4pm

    Read the article

  • Why are invariants important in Computer Science

    - by Antony Thomas
    I understand 'invariant' in its literal sense. I also recognize them when I type code. But I don't think I understand the importance of this term in the context of computer science. Whenever I read conversations\white papers about language design from famous programmers\computer scientists, the term 'invariant' keeps popping up as a jargon; and that is the part I don't understand. What is so special about it?

    Read the article

  • Obtaining Embedded Linux Experience

    - by Thomas Matthews
    As an embedded firmware developer, I have used operating systems such as WinCE, Nucleus, ThreadX, VRTX and some background loops. There are more opportunities for me if I had Linux OS experience, or perhaps some certification. In my research, the only way to get Linux experience is to have your company move to a Linux OS. All the recruiters and HR folks won't let you in the door unless you have Linux experience. I haven't found any Universities that teach Linux. Recruiters and HR want some tangible proof (starting up your own Ubuntu box or playing with it doesn't count). So, how does one get into the area of Embedded Linux without Linux experience (I have Unix and Cygwin experience, but not Linux)?

    Read the article

  • Can defect containment metrics be readily applied at an organizational level when there is only a consistant organizational process framework?

    - by Thomas Owens
    Defect containment metrics, such as total defect containment effectiveness (TDCE) and phase containment effectiveness (PCE), can be used to give a good indicator of the quality of the process. TDCE captures the defects that are captured at some point between requirements and the release of a product into the field, indicating the overall effectiveness of the entire process to find and remove defects. PCE provides more detail at each phase of the software development life cycle and how the defect detection and removal techniques are working. Applying these metrics makes sense at a level where you have a well-defined process and methodology for product development, often a project. However, some organizations provide a process framework that is tailored at the project level. This process framework would include the necessary guidance for meeting certifications (ISO9001, CMMI), practices for incorporating known good techniques (agile methods, Lean, Six Sigma), and requirements for legal or regulatory reasons. However, the specific details of how to gather requirements, design the system, produce the software, conduct test, and release are left to the product development teams. Is there any effective way to apply defect containment metrics at an organizational level when only a process framework exists at the organizational level? If not, what might be some ideas for metrics that can be distilled from each project (each using a tailored process that fits into the organizational process framework) that captures defect containment metrics to discuss the ability of the process to find and remove defects? The end goal of such a metric would be to consolidate the defect containment practices of a large number of ongoing projects and report to management. The target audience would be people in roles such as the chief software engineer and the chief engineer (of all engineering disciplines) for the organization. Although project specific data would be available, the idea is to produce something that quantifies the general effectiveness of all tailored processes across all ongoing projects. I would suspect that this data would also be presented as part of CMMI, ISO, or similar audits to demonstrate process quality.

    Read the article

  • Firefox 3.6.3 on Snow Leopard 10.6.3 - symbolic link to command line binary doesn't work?

    - by David Watson
    I have Firefox 10.6.3 installed on Mac OS X Snow Leopard from the DMG. I can run firefox from the terminal using /Applications/Firefox.app/Contents/MacOS/firefox-bin. However, if I create a symbolic link: sudo ln -s /Applications/Firefox.app/Contents/MacOS/firefox-bin /bin/firefox then it refuses to run, or at least display. When I issue "firefox" from the terminal, I can see the process in top, but never get the GUI to appear. :/ = ls -lr /bin/firefox lrwxr-xr-x 1 root wheel 52 May 5 15:19 /bin/firefox - /Applications/Firefox.app/Contents/MacOS/firefox-bin Any ideas? Thanks, David

    Read the article

  • Oral Tradition Check: Two Hundred Meanings for "NULL" in SQL

    - by Thomas L Holaday
    Two decades ago, the topic of "NULL" came up in conversation with a scholarly colleague. As I remember it, he said that C.J.Date, in an essay critical of commercial implementations of SQL, had listed over two hundred meanings for NULL. To my regret, I did not persist the details; but finding that list has since been on my Bucket List. Has anyone else heard this legend? Was it perhaps not Date, but another critic of commercial implementations of SQL?

    Read the article

  • DNS and WIldcards

    - by Thomas Chapman
    Whenever I attempt to make a record for *.schneiderdonnelly.com.au and CNAME it, I get two errors: You can't mix CNAME/MX records together using the same hostname. Domain root's cannot be CNAME's, however you can web-forward this record to www.schneiderdonnelly.com.au instead for the same effect. I've read it's possible so why can't I make it work? I donated $5 to be a premium member and I've been trying to make it work for yonks. http://i.stack.imgur.com/D9Ui5.jpg This is how I want it to appear. The last record. I am prepared to swap DNS providers as long as they're free.

    Read the article

< Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >