Search Results

Search found 14873 results on 595 pages for 'hard drives'.

Page 101/595 | < Previous Page | 97 98 99 100 101 102 103 104 105 106 107 108  | Next Page >

  • how to mount partitions from USB drives in Windows using Delphi?

    - by user569556
    Hi. I'm a Delphi programmer. I want to mount all partitions from USB drives in Windows (XP). The OS is doing this automatically but there are situations when such a program is useful. I know how to find if a drive is on USB or not. My code so far is: type STORAGE_QUERY_TYPE = (PropertyStandardQuery = 0, PropertyExistsQuery, PropertyMaskQuery, PropertyQueryMaxDefined); TStorageQueryType = STORAGE_QUERY_TYPE; STORAGE_PROPERTY_ID = (StorageDeviceProperty = 0, StorageAdapterProperty); TStoragePropertyID = STORAGE_PROPERTY_ID; STORAGE_PROPERTY_QUERY = packed record PropertyId: STORAGE_PROPERTY_ID; QueryType: STORAGE_QUERY_TYPE; AdditionalParameters: array[0..9] of AnsiChar; end; TStoragePropertyQuery = STORAGE_PROPERTY_QUERY; STORAGE_BUS_TYPE = (BusTypeUnknown = 0, BusTypeScsi, BusTypeAtapi, BusTypeAta, BusType1394, BusTypeSsa, BusTypeFibre, BusTypeUsb, BusTypeRAID, BusTypeiScsi, BusTypeSas, BusTypeSata, BusTypeMaxReserved = $7F); TStorageBusType = STORAGE_BUS_TYPE; STORAGE_DEVICE_DESCRIPTOR = packed record Version: DWORD; Size: DWORD; DeviceType: Byte; DeviceTypeModifier: Byte; RemovableMedia: Boolean; CommandQueueing: Boolean; VendorIdOffset: DWORD; ProductIdOffset: DWORD; ProductRevisionOffset: DWORD; SerialNumberOffset: DWORD; BusType: STORAGE_BUS_TYPE; RawPropertiesLength: DWORD; RawDeviceProperties: array[0..0] of AnsiChar; end; TStorageDeviceDescriptor = STORAGE_DEVICE_DESCRIPTOR; const IOCTL_STORAGE_QUERY_PROPERTY = $002D1400; var i: Integer; H: THandle; USBDrives: array of Byte; Query: TStoragePropertyQuery; dwBytesReturned: DWORD; Buffer: array[0..1023] of Byte; sdd: TStorageDeviceDescriptor absolute Buffer; begin SetLength(UsbDrives, 0); SetErrorMode(SEM_FAILCRITICALERRORS); for i := 0 to 99 do begin H := CreateFile(PChar('\\.\PhysicalDrive' + IntToStr(i)), 0, FILE_SHARE_READ or FILE_SHARE_WRITE, nil, OPEN_EXISTING, 0, 0); if H <> INVALID_HANDLE_VALUE then begin try dwBytesReturned := 0; FillChar(Query, SizeOf(Query), 0); FillChar(Buffer, SizeOf(Buffer), 0); sdd.Size := SizeOf(Buffer); Query.PropertyId := StorageDeviceProperty; Query.QueryType := PropertyStandardQuery; if DeviceIoControl(H, IOCTL_STORAGE_QUERY_PROPERTY, @Query, SizeOf(Query), @Buffer, SizeOf(Buffer), dwBytesReturned, nil) then if sdd.BusType = BusTypeUsb then begin SetLength(USBDrives, Length(USBDrives) + 1); UsbDrives[High(USBDrives)] := Byte(i); end; finally CloseHandle(H); end; end; end; for i := 0 to High(USBDrives) do begin // end; end. But I don't know how to access partitions on each drive and mounts them. Can you please help me? I searched before I asked and I couldn't find a working code. But if I did not properly then I'm sorry and please show me that topic. Best regards, John

    Read the article

  • Dedicated hard disk for SE dbname.dbs files & dedicated ramdisk for /tmp files.

    - by Frank Computer
    INFORMIX-SE 7.2: I would like to dedicate a hard disk, exclusively for my dbname.dbs directory which holds all the .dat and .idx files, and create a ramdisk for my /tmp temporary files in order to improve performance. I would also like to strip down the OS from any unecessary files and processes to minimize overhead for my dedicated application. Is this a good idea and are there any roadmaps for accomplishing this?

    Read the article

  • What is the best private cloud storage setup

    - by vdrmrt
    I need to create a private cloud and I'm searching for the best setup. These are my 2 most important requirements 1. Disk and system redundant 2. Price / GB as low as possible The system is going to be used as backup setup which will receive data 24/7 over SFTP and rsync. High throughput is not that important. I'm planning to use glusterfs and consumer grade 4TB hard-drives. I have worked out 3 possible setups 3 servers with 11 4TB HDD Setup up a replica 3 glusterfs and setup each hard drive as a separate ext4 brick. Total capacity: 44TB HDD / TB ratio of 0.75 (33HDD / 44TB) 2 servers with 11 4TB HDD The 11 hard-drives are combined in a RAIDZ3 ZFS storage pool. With a replica 2 gluster setup. Total capacity: 32TB (+ zfs compression) HDD / TB ratio of 0.68 (22HDD / 32TB) 3 servers with 11 4TB consumer hard-drives Setup up a replica 3 glusterfs and setup each hard-drive as a separate zfs storage pool and export each pool as a brick. Total capacity: 32TB (+ zfs compression) HDD / TB ratio of 0.68 (22HDD / 32TB) (Cheapest) My remarks and concerns: If a hard drive fails which setup will recover the quickest? In my opinion setup 1 and 3 because there only the contents of 1 hard-drive needs to be copied over the network. Instead of setup 2 were the hard-drive needs te be reconstructed by reading the parity of all the other harddrives in the system. Will a zfs pool on 1 harddrive give me extra protection against for example bit rot? With setup 1 and 3 I can loose 2 systems and still be up and running with setup 2 I can only loose 1 system. When I use ZFS I can enable compression which will give me some extra storage.

    Read the article

  • Why is my machine unable to mount my SMB drives ("CIFS VFS: Error connecting to socket. Aborting operation", return code -115)?

    - by downbeat
    I have a machine running Precise (12.04 x64), and I cannot mount my SMB drives (I have 3, we'll call them public, private and download). It used to work (a week or two ago) and I didn't touch fstab! The machine hosting the shares is a commercial NAS, and I'm not seeing anything that would indicate it's an issue with the NAS. I have an older machine which I updated to Precise at the same time (both fresh installed, not dist-upgrade), so should have a very similar configuration. It is not having any problems. I am not having problems on windows machines/partitions either, only one of my Precise machines. The two machines are using identical entries in fstab and identical /etc/samba/smb.conf files. I don't think I've ever changed smb.conf (has never mattered before). My fstab entries all basically look like this: //10.1.1.111/public /media/public cifs credentials=/home/downbeat/.credentials,iocharset=utf8,uid=downbeat,gid=downbeat,file_mode=0644,dir_mode=0755 0 0 Here's the dmesg output on boot: [ 51.162198] CIFS VFS: Error connecting to socket. Aborting operation [ 51.162369] CIFS VFS: cifs_mount failed w/return code = -115 [ 51.194106] CIFS VFS: Error connecting to socket. Aborting operation [ 51.194250] CIFS VFS: cifs_mount failed w/return code = -115 [ 51.198120] CIFS VFS: Error connecting to socket. Aborting operation [ 51.198243] CIFS VFS: cifs_mount failed w/return code = -115 There are no other errors I see in the dmesg output. Originally when I ran 'testparm -s', the output contained these lines ERROR: lock directory /var/run/samba does not exist ERROR: pid directory /var/run/samba does not exist Here's the samba related programs I have installed: $ dpkg --list|grep -i samba ii libpam-winbind 2:3.6.3-2ubuntu2.3 Samba nameservice and authentication integration plugins ii libwbclient0 2:3.6.3-2ubuntu2.3 Samba winbind client library ii nautilus-share 0.7.3-1ubuntu2 Nautilus extension to share folder using Samba ii python-smbc 1.0.13-0ubuntu1 Python bindings for Samba clients (libsmbclient) ii samba-common 2:3.6.3-2ubuntu2.3 common files used by both the Samba server and client ii samba-common-bin 2:3.6.3-2ubuntu2.3 common files used by both the Samba server and client ii winbind 2:3.6.3-2ubuntu2.3 Samba nameservice integration server $ dpkg --list|grep -i smb ii dmidecode 2.11-4 SMBIOS/DMI table decoder ii libsmbclient 2:3.6.3-2ubuntu2.3 shared library for communication with SMB/CIFS servers ii python-smbc 1.0.13-0ubuntu1 Python bindings for Samba clients (libsmbclient) ii smbclient 2:3.6.3-2ubuntu2.3 command-line SMB/CIFS clients for Unix ii smbfs 2:5.1-1ubuntu1 Common Internet File System utilities - compatibility package $ dpkg --list|grep -i cifs ii cifs-utils 2:5.1-1ubuntu1 Common Internet File System utilities ii libsmbclient 2:3.6.3-2ubuntu2.3 shared library for communication with SMB/CIFS servers ii smbclient 2:3.6.3-2ubuntu2.3 command-line SMB/CIFS clients for Unix I originally noticed that my other machine had "libpam-winbind" and "nautilus-share" installed and the machine with the issue did not. Installing those two packages solved my errors with 'testparm -s', but did not fix my issue. Finally, I tried to purge and reinstall these packages smbclient smbfs cifs-utils samba-common samba-common-bin Still no luck. Again, it used to work; now it doesn't. Very similarly configured machine works (but some packages are out of date on the working machine). The NAS has only one interface/IP address, nmblookup works to find it's IP from it's hostname (from the machine with the issue) and it responds to a ping. Please any help would be great. I've been searching on AskUbuntu, SuperUser, ubuntuforums and plain old search engines for a week now and it's driving me crazy!

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • SEI Turns Software Architecture into a Game

    - by Bob Rhubart-Oracle
    "Architecture is the decisions that you wish you could get right early in a project." -- Ralph E. Johnson Unless you can see into the future, getting those decisions right comes down to a collection of hard choices. But the Software Engineering Institute (SEI) of Carnegie Mellon University has turned those hard choices into a game. Literally. According to the SEI website: The Hard Choices game is a simulation of the software development cycle meant to communicate the concepts of uncertainty, risk, options, and technical debt. In the quest to become market leader, players race to release a quality product to the marketplace. By the end of the game, everyone has experienced the implications of investing effort to gain an advantage or of paying a price to take shortcuts, as they employ design strategies in the face of uncertainty.   Check it out for yourself: Download the Hard Choices Board Game Download the companion white paper: The Hard Choices Game Explained

    Read the article

  • How do you deal with the details when reading code?

    - by upton
    After reading some projects, I find that it is not the architecture of the software that is really hard to know. It is not hard to figure out the architecture immediately if the project is clearly designed and implemented, if it's hard and never seen before, some day later I can find out some pattern similar to the one I read in the same domain. The difficulty is that the concepts and mechanism defined by the author are really hard to guess, and these concepts may spread in the whole project which makes it hard to grasp. The situation is normal and universal and you can ask questions to your colleague when in a company. However, it gets worse if nobody around you knows these details. How do you handle these details which block your reading?

    Read the article

  • Can I create two databases, each for different directories?

    - by Tim
    I have run Recoll which created a database for my data partition on my internal hard drive. The database is stored under my home partition in the same internal hard drive. I now want to run Recoll to create a database for a dicrectory on my external hard drive, and store this new database on that external hard drive, because my internal hard drive doesn't have enough space to hold the new database. I was wondering how to do that in Recoll? Note: my current Recoll was installed from software center of Ubuntu 12.04. Thanks!

    Read the article

  • Is there a reason to use library backups if I'm backup up full disks?

    - by Ben Brocka
    In Windows Backup I can backup libraries or whole drives (or specific folders). I want a complete backup of all relevant drives. After selecting the drives, there's still the option to backup libraries: Is the backup going to do anything different if I include libraries as well as drives? Should I just backup the whole drive instead? Space used by the backup shouldn't be an issue, since I know the incremental backup is pretty smart..

    Read the article

  • USB Ports on the NETGEAR ReadyNAS NV+ 4-Bay 4TB

    - by Kyle Brandt
    I have several external USB drives currently (1x500GB and 2x1TB). If I were to purchase the ReadNAS NV+ 4TB NAS, would I be able to: Possibly add even more USB drives to it with a HUB? Export NFS shares of the data on the USB drives keeping the current ext3 fs and data on the USB drives intact? Does anyone have any caveats with this system they feel I should know?

    Read the article

  • How to remove RAID flag on unstriped drive without losing data?

    - by Alex Folland
    I have a Gigabyte Z68X-UD4-B3 motherboard. It advertises this new thing called "XHD", which is like RAID but makes a SSD and traditional-style drive work together to enable high speed with high capacity. I don't want to use this feature, and I already have Windows 7 64 installed without using this feature. When I first installed my 2 hard drives (1 SSD and 1 traditional-style drive) in my machine and booted it up for the first time, it ran a program from the mobo that asked me if I wanted to set up XHD. Thinking it would go to some config screen, I said yes. It immediately started doing something with my drives and finished. I considered that strange, but figured it wouldn't matter when I simply install Windows onto my SSD only. I now have my BIOS and Windows running in AHCI mode with no RAID arrays and separate drives. My SSD is one of those new Corsair Force GT drives which loses power every so often, causing Windows to BSOD. I've figured everything out about this problem, including installing the latest firmware from Corsair, and the only way to fix it at this point is by installing Intel Rapid Storage Technology to control AHCI instead of Windows, since the Windows AHCI driver disables the drive's power every once in a while and can't be configured not to do so. I've tried installing Intel Rapid Storage Technology. When I reboot my machine after doing so, it BSODs just after the Windows logo. I've figured out this is because my SSD and my traditional drive are flagged as RAID, as seen in the "Intel Matrix Storage Manager" program found by switching the BIOS hard drive handling to "RAID" mode. This is due to the XHD auto-config program I mentioned earlier. Normally, the BIOS is set to AHCI, and when the drives boot in AHCI mode, they work perfectly. So, I've concluded the data is stored in AHCI mode but the drives' flags are set to RAID. I've figured out that I can accomplish my objective by using the "Intel Matrix Storage Manager" program on the mobo (with "Reset disks to non-RAID"), but doing so would cause it to completely wipe the drives I select. I want to simply toggle these flags from RAID to AHCI so Intel Rapid Storage Technology doesn't fail and cause a BSOD upon booting, but without wiping the drives.

    Read the article

  • How hard is it to modify the Django Models?

    - by alex
    I am doing geolocation, and Django does not have a PointField. So, I am forced to writing in RAW SQL. GeoDjango, the Django library, does not support the following query for MYSQL databases (can someone verify that for me?) cursor.execute("SELECT id FROM l_tag WHERE\ (GLength(LineStringFromWKB(LineString(asbinary(utm),asbinary(PointFromWKB(point(%s, %s)))))) < %s + accuracy + %s)\ I don't nkow why GeoDjango library cannot do this in MYSQL database. I hate writing RAW SQL for calculating distances between two points. Is there a way I can create my own library for Django that can handle this? If so, how hard is it?

    Read the article

  • How do I load the Oracle schema into memory instead of the hard drive?

    - by Andrew
    I have a certain web application that makes upwards of ~100 updates to an Oracle database in succession. This can take anywhere from 3-5 minutes, which sometimes causes the webpage to time out. A re-design of the application is scheduled soon but someone told me that there is a way to configure a "loader file" which loads the schema into memory and runs the transactions there instead of on the hard drive, supposedly improving speed by several orders of magnitude. I have tried to research this "loader file" but all I can find is information about the SQL* bulk data loader. Does anyone know what he's talking about? Is this really possible and is it a feasible quick fix or should I just wait until the application is re-designed?

    Read the article

  • How do I git reset --hard HEAD on Mercurial?

    - by obvio171
    I'm a Git user trying to use Mercurial. Here's what happened: I did a hg backout on a changeset I wanted to revert. That created a new head, so hg instructed me to merge (back to "default", I assume). After the merge, it told me I still had to commit. Then I noticed something I did wrong when resolving a conflict in the merge, and decided I wanted to have everything as before the hg backout, that is, I want this uncommited merge to go away. On Git this uncommited stuff would be in the index and I'd just do a git reset --hard HEAD to wipe it out but, from what I've read, the index doesn't exist on Mercurial. So how do I back out from this?

    Read the article

  • Is a class that is hard to unit test badly designed?

    - by Extrakun
    I am now doing unit testing on an application which was written over the year, before I started to do unit-testing diligently. I realized that the classes I wrote are hard to unit test, for the following reasons: Relies on loading data from database. Which means I have to setup a row in the table just to run the unit test (and I am not testing database capabilities). Requires a lot of other external classes just to get the class I am testing to its initial state. On the whole, there don't seem to be anything wrong with the design except that it is too tightly coupled (which by itself is a bad thing). I figure that if I have written automated test cases with each of the class, hence ensuring that I don't heap extra dependencies or coupling for the class to work, the class might be better designed. Does this reason holds water? What are your experiences?

    Read the article

  • Algorithm to classify a list of products?

    - by Martin
    I have a list representing products which are more or less the same. For instance, in the list below, they are all Seagate hard drives. Seagate Hard Drive 500Go Seagate Hard Drive 120Go for laptop Seagate Barracuda 7200.12 ST3500418AS 500GB 7200 RPM SATA 3.0Gb/s Hard Drive New and shinny 500Go hard drive from Seagate Seagate Barracuda 7200.12 Seagate FreeAgent Desk 500GB External Hard Drive Silver 7200RPM USB2.0 Retail For a human being, the hard drives 3 and 5 are the same. We could go a little bit further and suppose that the products 1, 3, 4 and 5 are the same and put in other categories the product 2 and 6. We have a huge list of products that I would like to classify. Does anybody have an idea of what would be the best algorithm to do such thing. Any suggestions? I though of a Bayesian classifier but I am not sure if it is the best choice. Any help would be appreciated! Thanks.

    Read the article

  • I'm having a hard time wrapping my head around handling the Activity Lifecycle...

    - by kefs
    So it seems i've created a fatal flaw and coded an app before understanding/handling rotation/lifecycle events.. Currently, all of my code is in onCreate of each activity. I've read a lot of lifecycle tutorials online, including the official dev guide info, but i'm still having an almost unbelievably hard time trying to wrap my head around the rotation/lifecycle events/methods and when to use them correctly. For example, my app currently has an activity that opens the db, inserts a record, then closes the db.. if i rotate my screen on this activity, the data is re-entered into the db. Using the available lifecycle events (onPause(), onResume(), etc..), how would I prevent this db call from happening again? Would I have to pass a variable through the state saying that the db call has been done, and not to do it again? Thanks in advance..

    Read the article

  • Using the windows api and C++, how could I load an exe from the hard drive and run it in its own thread?

    - by returneax
    For the sake of learning I'm trying to do what the OS does when launching a program ie. parsing a PE file and giving it a thread of execution. If I have two exe's one called foo.exe and the other bar.exe, how could I have foo.exe load the contents of bar.exe into memory then have it execute from there in its own thread? I know how to get it into memory using MapViewOfFile or by simple loading the contents on the hard drive into a buffer. I'm assuming simply copying the contents of bar.exe on disk into its own suspended thread and running it wouldn't work. I am semi-familiar with PE file internals. All help is very much appreciated, of course :)

    Read the article

  • Can Eclipse not hard-code ECLIPSE_HOME when exporting build.xml?

    - by stevex
    I have an Eclipse project that I'm attempting to set up to build both with Eclipse and externally with Ant. It seems like a good way to do this is to have Eclipse generate a build.xml file that I can then use with ant. I'd like to set it up so the build.xml can be regenerated from Eclipse whenever the need arises, which means no hand-editing the build.xml file. But Eclipse writes one entry in there that has a hard-coded path to a directory on my computer, which makes it unsuitable for checking in to a source repository. Specifically it's this entry that's the trouble: <property name="ECLIPSE_HOME" value="D:/Eclipse/Eclipse Galileo (3.5) SR1"/> Is there some way to have Eclipse not output this line, or to make it a relative reference or something that makes sense to check in?

    Read the article

  • How do I restore an Apache configuration after a hard restart?

    - by iPhoneARguy
    I installed Apache on my Ubuntu server, and when it installed, it created a directory ~/Apache/ with directories such as htdocs, logs, cgi-bin, etc. I was then able to create several pages and scripts which I placed into the corresponding directories (~/Apache/htdocs, ~/Apache/cgi-bin), and I was able to serve these files on the web. Unfortunately, my server had an unexpected hard restart, and since then, it seems like the files aren't being served. The server is still up, but when I navigate to the URL, I get a page that says "It works!" instead of what was expected. Does anyone know how I can get Apache to serve from ~/Apache/htdocs again? I tried to RTFM and Google for an answer already but it wasn't very helpful.

    Read the article

  • Vista install works on one computer, but bluescreens another (on which Vista is known to work)

    - by Ken
    I hope my explanations make some sense -- please ask for clarification if they don't. I had a computer running Windows Vista (Ultimate, 64-bit). All was well! Then one day there was a nasty power surge at the office, and it died. (We didn't have surge protectors at the office, unfortunately. I assumed our lines were conditioned elsewhere, or was not an issue here. Oops.) After some testing, it was determined that the PSU, motherboard, and RAM were bad. While waiting for new hardware to arrive, I put my hard disk in a spare PC which had identical parts (mobo/CPU/RAM/PSU/video). Everything worked perfectly. The only way I could even tell it wasn't my computer is because Vista asked to re-activate itself with the new hardware, which worked fine, too. So the hard disk seems OK. Then the new parts arrived. The old motherboard model is no longer manufactured, so it's a new one with the same CPU/RAM/videocard/etc. slots. The PSU is also new, while the RAM I'm using is from the spare PC mentioned above. When I put it together and tried booting with my old hard disk, it starts to boot Windows, and then (fairly early in the process) gives a bluescreen and immediately reboots (so I can't see whatever the bluescreen is trying to tell me). I tried "safe mode", which also bluescreened. I tried booting the Vista DVD and running the repair utility, which found a Vista install, confirmed that it would not boot, and, eventually, declared that it was unable to repair it. I installed Vista fresh on a new hard disk, with the new mobo/etc., and it works perfectly. (That's what I'm running now.) I've also booted a Linux CD here, which ran great, and I've run Memtest86+ for a while, which found no errors. So all the hardware apart from the old hard disk seems OK, too. I don't think the problem is with my old Vista hard disk, since I used that with another mobo/CPU just fine. I don't think it's any other part of the new hardware, since I'm able to use it (and test it) with no trouble. It's just the combination of my old Vista install plus the new PC hardware that's not happy. I can get my data off my old hard disk and onto my new hard disk, and reinstall my apps, but it would be nice if I could fix things so I could continue to use my old hard disk as before. The latest hypothesis I've heard is that Vista had trouble with the new hardware (i.e., motherboard), but we have no idea what to do about that (except Safe Mode, which didn't work). Suggestions? Hypotheses for what's not right about this combination of Vista install and motherboard? Thanks!

    Read the article

  • What is causing random hard freezes on my system? Kaspersky?

    - by Christian Ivicevic
    The last few weeks I experienced a new strange behavior of my computer. Sometimes Windows 7 just freezes with no real reason at all. While listening to music for example the playback hangs and you can hear a very nasty sound. Neither mouse nor keyboard input is handled and everything is just stuck. Using Ubuntu this does not happen, so I think it is just a matter of driver issues or a Windows 7 bug. Furthermore I am really suspicious about Kaspersky (Internet Security 11) and so I let it perform a complete virus scan while no other app is running. At about 50% it happened again and I needed to restart the computer by holding the power button the bad way... A really weird thing is that playing Skyrim this happened once, however music playback did not stop. Only the framerate dropped to 0 and sometimes for a few seconds I am able to move. Therefore I am really confused as furthermore no bluescreen pops up. Memtest told me that everything seems to be alright... Can anyone explain me which data you need about my hardware and software (and which tools tools to use to gather the informatik) to be able to provide any help on my problem?

    Read the article

  • Random Hard Freeze of Windows 7 (is Kaspersky to be blamed for this?)

    - by Christian Ivicevic
    The last few weeks I experienced a new strange behavior of my computer. Sometimes Windows 7 just freezes with no real reason at all. While listening to music for example the playback hangs and you can hear a very nasty sound. Neither mouse nor keyboard input is handled and everything is just stuck. Using Ubuntu this does not happen, so I think it is just a matter of driver issues or a Windows 7 bug. Furthermore I am really suspicious about Kaspersky (Internet Security 11) and so I let it perform a complete virus scan while no other app is running. At about 50% it happened again and I needed to restart the computer by holding the power button the bad way... A really weird thing is that playing Skyrim this happened once, however music playback did not stop. Only the framerate dropped to 0 and sometimes for a few seconds I am able to move. Therefore I am really confused as furthermore no bluescreen pops up. Memtest told me that everything seems to be alright... Can anyone explain me which data you need about my hardware and software (and which tools tools to use to gather the informatik) to be able to provide any help on my problem?

    Read the article

< Previous Page | 97 98 99 100 101 102 103 104 105 106 107 108  | Next Page >