Search Results

Search found 10936 results on 438 pages for 'monitor refresh rate'.

Page 101/438 | < Previous Page | 97 98 99 100 101 102 103 104 105 106 107 108  | Next Page >

  • What is an Acer Converter Port?

    - by ShadowHero
    What is this port "Acer Converter Port"? Very little information can be found on the internet. It's basically the same as miniDP? Can I connect a monitor like Dell U2713H on this one? EDIT From this page: http://acer.custhelp.com/app/answers/detail/a_id/30837/~/frequently-asked-questions-on-the-aspire-r7-series 9. Can I connect a DisplayPort monitor to the Acer Converter Port? The Acer Converter Port uses the same physical port as a Mini DisplayPort, but is designed to connect to an Acer proprietary cable. If you connect a DisplayPort monitor, Acer cannot guarantee the functionality of the monitor. No damage should occur to either monitor or notebook by connecting a Mini DisplayPort cable. So, the question is, can someone confirm this will work for sure?

    Read the article

  • jQuery - Show field based on value of a type-hidden on refresh.

    - by Sebhael
    Hello, I'm trying to create something in jQuery and having a bit of problems with it. I'm not too adept on the framework, so I'm sure this is all wrong. Anyways, the ultimate goal is a full form that contains 3 radio buttons - depending on the value of the button, a LI is shown. I have all of that done, but my problem is coming with validation. If something fails then the page is reloaded and the div that was selected doesn't show without clicking another radio first, then back to the original. This process is basically the same as someone came up with here. Here's what I got so far. HTML <li> <label> License (radio) </label> <label for="commercial" class="checkBox"> Commercial </label> <input type="radio" name="license" value="commercial" id="commercial" class="checkBox" <?php echo set_radio('license', 'commercial'); ?> /> <label for="abandonware" class="checkBox"> Abandonware </label> <input type="radio" name="license" value="abandonware" id="abandonware" class="checkBox" <?php echo set_radio('license', 'abandonware'); ?> /> <label for="freeware" class="checkBox"> Freeware </label> <input type="radio" name="license" value="freeware" id="freeware" class="checkBox" <?php echo set_radio('license', 'freeware'); ?> /> </li> This is followed by three LI's that contain id="commercial, abandonware, and freeware" and class="licenseli" My jQuery is, as said, something from here. $('li.licenseli').hide(); $('input[name=license]:radio').change(function(){ var Type = $(this).val(); // Get value of radio $('li.licenseli').slideUp(); // Hide non-selected $('li#'+Type).slideDown(); // Show Selected }); So what I need help with is I have a hidden input that retrieves the value of the radio box from validation - I want to take this value (or the radio's if possible?) and have the original selected option's LI already visible.

    Read the article

  • How do you automatically refresh part of a page automatically using Javascript or AJAX?

    - by Ryan
    $messages = $db->query("SELECT * FROM chatmessages ORDER BY datetime DESC, displayorderid DESC LIMIT 0,10"); while($message = $db->fetch_array($messages)) { $oldmessages[] = $message['message']; } $oldmessages = array_reverse($oldmessages); ?> <div id="chat"> <?php for ($count = 0; $count < 9; $count++) { echo $oldmessages[$count]; } ?> <script language="javascript" type="text/javascript"> <!-- setInterval( "document.getElementById('chat').innerHTML='<NEW CONTENT OF #CHAT>'", 1000 ); --> </script> </div> I'm trying to create a PHP chatroom script but I'm having a lot of trouble getting it to AutoRefresh The content should automatically update to , how do you make it do that? I've been searching for almost an hour

    Read the article

  • Mac Safari randomly recreating cookie when I refresh my login screen. Very bizarre

    - by mcintyre321
    We have found an issue in our app where Safari on the Mac randomly recreates a login cookie from a logged off session. I have a fiddler archive with this behaviour here. Note that some stuff has been removed from this to make it easier to get, but nothing which sets a cookie or anything has been taken out - only repetitions of requests 3-8. I'll talk you through the running order Request 1: user logs out via call to /logout.aspx - Set-Cookie returned setting cookie expiry date to 1999 Requests 2-8: user refreshes login page sending calls to root or /res/en-US/s.js - no cookie is sent to server or received back, and access is denied. I have cut out a lot of requests of this nature from the log as they are boring Request 9: request for /res/en-US/s.js - Hv3 authentication cookie has mysteriously reappeared! Wat. There was NO set-cookie! WTFF! Request 10+ : now the cookie has reappeared, the site logs the user in AGAIN The cookie, when examined in Safari looks like <dict> <key>Created</key> <real>259603523.26834899</real> <key>Domain</key> <string>.mysite.dev</string> <key>Expires</key> <date>2010-03-24T16:05:22Z</date> <key>HttpOnly</key> <string>TRUE</string> <key>Name</key> <string>.Hv3</string> <key>Path</key> <string>/</string> </dict> One thing to note is that in Safari, the cookie domain is .mysite.dev not mysite.dev (which is the cookie domain specified in web.config) - however, given that access is denied in requests 2-8, it looks like the cookie has expired OK. If you look in the list of cookies in the browser during 2-8, the .Hv3 cookie is not there. Is this our bug or Safari's? What can I do to stop it happening?

    Read the article

  • How can I increase resolution when impossible to set up nvidia driver?

    - by Asimov4
    I was stuck at 1024x758 before creating an /etc/X11/xorg.conf file as follows which works well to allow me to have a resolution of 1920x1200 with the vesa driver. Section "Device" Identifier "Configured Video Device" Driver "vesa" EndSection Section "Monitor" Identifier "Configured Monitor" HorizSync 24.0 - 83.0 VertRefresh 50.0 - 75.0 EndSection Section "Screen" Identifier "Default Screen" Monitor "Configured Monitor" Device "Configured Video Device" SubSection "Display" Viewport 0 0 Depth 24 Modes "1920x1200" EndSubSection EndSection But now my display is kind of slow. I have an NVIDIA GeForce 8600GT but really cannot find how to set up the driver to work. Are there any alternatives to VESA that would work faster?

    Read the article

  • Practical PowerShell for SQL Server Developers and DBAs – Part 2

    Having shown just how useful PowerShell can be for DBAs in executing queries, Michael Sorens now takes us through navigating SQL Server space and finding meta-information - valuable information for anyone looking to be more productive in SQL Server. What can SQL Monitor 3.2 monitor?Whatever you think is most important. Use custom metrics to monitor and alert on data that's most important for your environment. Find out more.

    Read the article

  • SQLServerCentral Best Practices Clinic: Part 1

    We exposed the SQLServerCentral cluster for monitoring with SQL Monitor. Just like other companies, we have constraints on resources, and we have more work that needs to be done. Help us configure SQLServerCentral’s database servers with your suggestions on what is the highest priority for a website database back end. NEW! SQL Monitor 2.0Monitor SQL Server Central's servers withRed Gate's new SQL Monitor.No installation required. Find out more.

    Read the article

  • How do you automatically refresh part of a page automatically using AJAX?

    - by Ryan
    $messages = $db->query("SELECT * FROM chatmessages ORDER BY datetime DESC, displayorderid DESC LIMIT 0,10"); while($message = $db->fetch_array($messages)) { $oldmessages[] = $message['message']; } $oldmessages = array_reverse($oldmessages); ?> <div id="chat"> <?php for ($count = 0; $count < 9; $count++) { echo $oldmessages[$count]; } ?> <script language="javascript" type="text/javascript"> <!-- setInterval( "document.getElementById('chat').innerHTML='<NEW CONTENT OF #CHAT>'", 1000 ); --> </script> </div> I'm trying to create a PHP chatroom script but I'm having a lot of trouble getting it to AutoRefresh The content should automatically update to , how do you make it do that? I've been searching for almost an hour

    Read the article

  • Multiple Monitors on One Screen

    - by Hulihan Applications
    Does anyone know of any software/hardware configuration that will allow you to preview/view the contents multiple monitors on one monitor? Let's pretend: I have two monitors hooked up to one pc, Monitor A and Monitor B. The monitors are not near each other. I'd like to be able to preview/see what's displaying on Monitor B on Monitor A I haven't been able to find much about this, but I imagine it may not currently be possible to access/emulate video output going out of a video port in software. However, wouldn't it be possible to capture display data generated by the OS kernel or data getting passed down to the display adapter driver?

    Read the article

  • Upgrading SSIS Custom Components for SQL Server 2012

    Having finally got around to upgrading my custom components to SQL Server 2012, I thought I’d share some notes on the process. One of the goals was minimal duplication, so the same code files are used to build the 2008 and 2012 components, I just have a separate project file. What can SQL Monitor 3.2 monitor?Whatever you think is most important. Use custom metrics to monitor and alert on data that's most important for your environment. Find out more.

    Read the article

  • Defcon totally screwed up my system!

    - by Draeton
    I'm using Ubuntu 12.04. Downloaded and ran a game called Defcon, by Introversion Software, and then my display problems began! At first, my smallest monitor stopped receiving input. Then, when I exit the game, still no input & I look at the 'Display' System Settings menu and it is off. I try switching it back on, and my system totally crashes. I restart my system, and try two more times at switching it back on, before I go back to basics and switch mirroring on before switching that monitor on. Now I've switched mirroring off, but if I set the resolution for my largest monitor above that of my other monitor, my system crashes! What the heck! Does anyone have a solution to my problems?

    Read the article

  • Bumblebee screwd up my grafics-settings

    - by user104762
    I had my system working pretty good with the external monitor working with the displayport. Unfortunately I felt that I should try to install Bumblebee. It didn't work. The monitor wasn't recognised. So I uninstalled it with the instructions on ubuntus wiki. But it didn't get back to the way it was. And when I copied the Purge-command it started deleting other stuff to, like Cheese and whatnot. I can't get the external monitor to be recognised. If I activate Optimus I get the right settings on my laptopscreen, but no Nvidia-drivers. If I deactivate optimus I get poor resolution on my laptopscreen, and still don't recognise the external monitor. But the Nvidia-drivers show up and can be activated. Why oh why did I have to try to install Bumblebee.

    Read the article

  • How to maximise a Single Window across Multiple Monitors?

    - by LePressentiment
    Say I've 3 monitors. I'll instantiate with http://www.texpaste.com/. What would I need for: The leftmost toolbox to be on the leftmost monitor? The center input blank field on the center monitor? The rightmost output display box on the rightmost monitor? Another example with 2 monitors: http://mathb.in/ Analogously, in this case, I'd want: The input blank field for the code on the left monitor? The rightoutput display box on the right monitor?

    Read the article

  • when i refresh the page, the popup window is visible for a second. How to clear this issue

    - by mano
    script $(document).ready(function(){ $(".aboutBtn").click(function () { $(".aboutContent").slideToggle("slow"); }); $(".contact").click(function () { $(".aboutContent").slideToggle("slow"); }); }); *Html * <article class="aboutBtn">ABOUT</article> Css .aboutBtn{ width:85px; padding:5px 0px 5px 10px; background-color:#d8531e; cursor:pointer; color:#ffffff; font-size:20px; text-transform:uppercase; position:relative;top:-48px; font-family:"Segoe UI Light"; }

    Read the article

  • how to detect an F5 refresh keypress event in jquery?

    - by chaonextdoor
    I noticed that jquery has a keypress function. But it seems that it can only detect keypress event of numbers and characters. It cannot detect the F5 keypress event. And What surprises me the most is everyone online says that the keyCode of F5 is 116, But when I use the jquery keypress function, it just shows that the character t has the keyCode of 116(it seems that 116 is the ascii code of lowercase t)! Can somebody give me any idea about this and how to detect the F5 event in javascript or jquery? Thanks so much in advance.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Ubuntu/Nvidia lists DVI dual cable as single

    - by Joseph Mastey
    I have an NVidia Quadro FX 880M graphics card, from which I am trying to drive 2 monitors: my internal laptop montior (15.6", 1920x1080, Nvidia driver says it's running via DisplayPort) and an external 27" monitor (Dell U2711, 2560x1440 native resolution, via DVI). I've hooked the dual DVI cable to the dual DVI port on my dock (Dell PR03X) and installed the proprietary NVidia driver, but I cannot seem to get the full 2560x1440 out of the larger 27" external monitor. Looking at the NVidia driver settings, the monitor's connection is reported as a single DVI cable, rather than a dual one, which would explain the reduced resolution. Does anyone have any experience with an issue like this? What can I do to make full use of my new monitor? (Possibly) Relevant Information: There is no DVI port on the laptop itself, but one is provided via the dock. The laptop and dock both provide a DisplayPort jack, but I have been unable to get this working on either w/ the monitor. I did have the nouveau driver installed when I installed the nvidia proprietary driver, but have since removed it (no change in the monitor situation when I removed it). The 27" reports a max resolution of 1680x1050. Thanks, Joe

    Read the article

  • GNOME 2 + Compiz equivalent?

    - by virtualeyes
    Running Fedora 14 and realize I need to either change distros or find an alternative to GNOME 3 in Fedora 17. Based on what I have read to-date, XFCE and KDE are the go-to WMs if I want to avoid GNOME 3. I tried KDE 4 and I wasn't impressed; I like the simplicity of GNOME 2 with Compiz and Emerald. Can't stay on Fedora 14 forever, however, so...where to turn? Basically looking for these features in my desktop environment: GNOME Do or equivalent Snap to grid/Window tiling A must-have, the ability to hot key focused window to a monitor grid region is a huge productivity win. Zoom window to cursor In a multi-monitor setup sometimes it's nice to, say, GNOME Do terminal in one monitor and then hot key the opened window to the other monitor just by zipping the mouse cursor anywhere on target monitor (followed by, of course, snap-to-grid hotkey, all without a single mouse click) Polarization At night white background hurts the eyes, so I prefer to hot key polarize to black. Multi-monitor support I'm partial to Fedora given that I've worked with CentOS for years and have little experience with any other Linux distro; however, if the difference between Fedora and Arch, Mint, etc. is fairly subtle, I'll make the leap, just need a distro & desktop environment that allows me to be productive with keyboard hot keys and provides the above basic features. Any suggestions?

    Read the article

  • Lenovo S110 netbook screen resolution Ubuntu

    - by Neigyl R. Noval
    I am still stuck with 800x600 resolution. Here is the output of lspci: 00:00.0 Host bridge: Intel Corporation Device 0bf2 (rev 03) 00:02.0 VGA compatible controller: Intel Corporation Device 0be2 (rev 09) 00:1b.0 Audio device: Intel Corporation N10/ICH 7 Family High Definition Audio Controller (rev 02) 00:1c.0 PCI bridge: Intel Corporation N10/ICH 7 Family PCI Express Port 1 (rev 02) 00:1c.1 PCI bridge: Intel Corporation N10/ICH 7 Family PCI Express Port 2 (rev 02) 00:1c.2 PCI bridge: Intel Corporation N10/ICH 7 Family PCI Express Port 3 (rev 02) 00:1d.0 USB Controller: Intel Corporation N10/ICH7 Family USB UHCI Controller #1 (rev 02) 00:1d.1 USB Controller: Intel Corporation N10/ICH 7 Family USB UHCI Controller #2 (rev 02) 00:1d.2 USB Controller: Intel Corporation N10/ICH 7 Family USB UHCI Controller #3 (rev 02) 00:1d.3 USB Controller: Intel Corporation N10/ICH 7 Family USB UHCI Controller #4 (rev 02) 00:1d.7 USB Controller: Intel Corporation N10/ICH 7 Family USB2 EHCI Controller (rev 02) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev e2) 00:1f.0 ISA bridge: Intel Corporation NM10 Family LPC Controller (rev 02) 00:1f.2 SATA controller: Intel Corporation N10/ICH7 Family SATA AHCI Controller (rev 02) 00:1f.3 SMBus: Intel Corporation N10/ICH 7 Family SMBus Controller (rev 02) 01:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8101E/RTL8102E PCI Express Fast Ethernet controller (rev 05) 02:00.0 Network controller: Realtek Semiconductor Co., Ltd. Device 8176 (rev 01) Also, I tried modifying /usr/lib/X11/xorg.conf.d/10-monitor.conf to fix this problem, but still does not work: Section "Monitor" Identifier "Monitor0" VendorName "Monitor Vendor" ModelName "Monitor Model" EndSection Section "Screen" Identifier "Screen0" Monitor "Monitor0" Device "Card0" SubSection "Display" Viewport 0 0 Depth 1 Modes "1024x768" EndSubSection SubSection "Display" Viewport 0 0 Depth 4 Modes "1024x768" EndSubSection SubSection "Display" Viewport 0 0 Depth 8 Modes "1024x768" EndSubSection SubSection "Display" Viewport 0 0 Depth 15 Modes "1024x768" EndSubSection SubSection "Display" Viewport 0 0 Depth 16 Modes "1024x768" EndSubSection SubSection "Display" Viewport 0 0 Depth 24 Modes "1024x768" EndSubSection EndSection Section "Device" Identifier "Card0" Driver "vesa" VendorName "Intel Corporation Device" EndSection I'm using Gnome. System Preference Monitor screen resolution sticks to 800x600. What am I going to do?

    Read the article

  • Running python script in incrontab in Debian

    - by WilliamMayor
    I have a user, dropbox, that runs the Dropbox daemon, I want to monitor the directories in the Dropbox directory for new files and run a python script when they appear. I have the python script that I know works: $ /home/dropbox/monitor.py Trying to get lock Got lock, waiting for Dropbox to be idle Dropbox idle Finding instructions Done, releasing lock I have an incrontab entry: $ incrontab -l /home/dropbox/Dropbox IN_CREATE /home/dropbox/monitor.py | logger /home/dropbox/test IN_CREATE logger "$$ $@ $# $% $&" When I add a file to the test directory I see the output in /var/log/syslog: $ touch /home/dropbox/test/a $ tail /var/log/syslog ... Nov 9 10:18:27 vps incrond[1354]: (dropbox) CMD (logger "$ /home/dropbox/test a IN_CREATE 256") Nov 9 10:18:27 vps logger: "$ /home/dropbox/test a IN_CREATE 256" ... However, when I add a file to the Dropbox directory the command doesn't seem to run: $ touch /home/dropbox/Dropbox/a $ tail /var/log/syslog ... Nov 9 10:24:16 vps incrond[1354]: (dropbox) CMD (/home/dropbox/monitor.py | logger) ... So the incron daemon notices the new file and the correct command is found to be executed but it never actually gets executed. Nor are there any error messages. It kind of seems like incrontab can only be used to run the most simple of commands. This might be a similar question to: Incrond running but not executing commands CentOS 6.4 but I think that I don't have env problems, every path is absolute. I tried changing .../monitor.py to /usr/bin/python2.7 .../monitor.py just in case but it didn't make any difference.

    Read the article

  • Prevent Windows from resizing all the apps on the desktop when switching monitors

    - by Greg Hewgill
    Short version: When moving my laptop and sleeping between using different monitors, all my open windows are crammed into the upper left corner as if they tried to fit on the laptop internal screen resolution. I plug in and switch to the external monitor before unlocking my session. Is there a way to prevent this automatic resizing? Longer version: I have a laptop that I move between two locations. I have one docking station, and the same kind of monitor configured for 1600x1200, in both locations. The internal laptop screen is awful so I don't use it. Location A: Docking station, monitor connected via DVI. Location B: No docking station, external monitor connected via VGA cable. In this location I have the laptop lid open for keyboard access but I don't use the laptop screen. When moving from Location A to Location B, the laptop wakes up from sleep, displaying the screen on the internal monitor. I switch to the external monitor display (using Fn+F8 on this laptop), and only after that do I unlock my session with my password. However, Windows has crammed all my nicely arranged windows into the upper left corner as if it were trying to fit them all on the laptop internal screen resolution. When moving from Location B to Location A, I have the laptop lid closed when using the docking station so Windows apparently concludes the screen resolution is 1600x1200 and doesn't resize any windows. The laptop is a Dell Latitude running Windows 7 Professional.

    Read the article

< Previous Page | 97 98 99 100 101 102 103 104 105 106 107 108  | Next Page >