Search Results

Search found 3463 results on 139 pages for 'physical'.

Page 101/139 | < Previous Page | 97 98 99 100 101 102 103 104 105 106 107 108  | Next Page >

  • I am getting a SQUID Error

    - by Dave
    Hello, What exactly is wrong here Entry in SQUID File--- httpd_accel_host virtual httpd_accel_port 80 httpd_accel_with_proxy on httpd_accel_uses_host_header on acl lan src 192.168.1.1 192.168.2.0/24 http_access allow localhost Error after: service squid restart 2010/02/01 14:24:29| Processing Configuration File: /etc/squid/squid.conf (depth 0) 2010/02/01 14:24:29| cache_cf.cc(361) parseOneConfigFile: squid.conf:10 unrecognized: 'broken_vary_encoding' 2010/02/01 14:24:29| WARNING: Netmasks are deprecated. Please use CIDR masks instead. 2010/02/01 14:24:29| WARNING: IPv4 netmasks are particularly nasty when used to compare IPv6 to IPv4 ranges. 2010/02/01 14:24:29| WARNING: For now we assume you meant to write /0 2010/02/01 14:24:29| WARNING: (B) '::/4294967200' is a subnetwork of (A) '::' 2010/02/01 14:24:29| WARNING: because of this '::' is ignored to keep splay tree searching predictable 2010/02/01 14:24:29| WARNING: You should probably remove '::/4294967200' from the ACL named 'all' 2010/02/01 14:24:29| WARNING: Netmasks are deprecated. Please use CIDR masks instead. 2010/02/01 14:24:29| WARNING: IPv4 netmasks are particularly nasty when used to compare IPv6 to IPv4 ranges. 2010/02/01 14:24:29| WARNING: For now we assume you meant to write /128 2010/02/01 14:24:29| aclParseIpData: unknown netmask '255.255.255.255' in '127.0.0.1/255.255.255.255' FATAL: Bungled squid.conf line 25: acl localhost src 127.0.0.1/255.255.255.255 Squid Cache (Version 3.1.0.14): Terminated abnormally. CPU Usage: 0.013 seconds = 0.006 user + 0.007 sys Maximum Resident Size: 0 KB Page faults with physical i/o: 0 Also please provide me with the simplest squid script for the proxy to run. Restrictions can be entered. Thanks Dave

    Read the article

  • Group policy waited for the network subsystem

    - by the-wabbit
    In an AD domain with Windows Server 2008 R2 DCs users are complaining about delays in the bootup process of the clients. The group policy log reveals that the client is waiting ~ 20-50 seconds for "the network subsystem": Event 5322, GroupPolicy Group policy waited for 29687 milliseconds for the network subsystem at computer boot. This appears to be domain-specific as machines joining a different domain from the same network do not experience any delays and Event 5322 reports <1000 ms wait times at startup. It happens on virtual and physical machines alike, so it does not look like a hardware- or driver-related issue. Further investigation has shown that the client is taking its time before issuing DHCP requests. In the network traces, I can see IPv6 router solicitations and multicast DNS name registrations as soon as the network driver is loaded and the network connection is reported "up" in the event log (e1cexpress/36). Yet, the DHCPv4 client service seems to take another 15-50 seconds to start (Dhcp-Client/50036), so the IPv4 address remains unconfigured for a while. The DHCP client's messages in the event log are succeeding the service start of the "Sophos Anti-Virus" service (Sophos AV 10.3 package), which I suspect to be the culprit - the DHCP client service dependencies include the TDI Support driver which might be what Sophos is using to intercept network traffic: Network Location Awareness seems to break at startup as a side-effect, I see that off-site DCs are contacted due to what seems like a race condition between the GP client and the DHCP client / NLA service startup. I could set the Group Policy Client service to depend on NLA, yet this still would not eliminate the delay. Also, I am not all that sure that this is a good idea. Is there a known resolution which would eliminate the startup delay?

    Read the article

  • iSCSI errors continue after removing inaccessible target portal

    - by Ansgar Wiechers
    By mistake I entered an iSCSI target portal address in the iSCSI Initiator on one of our virtual servers that does not have an address in the network range used for iSCSI. This caused the following errors/warnings to appear in the eventlog: Log Name: System Source: MSiSCSI Event ID: 113 Level: Warning Description: iSCSI discovery via SendTargets failed with error code 0xefff0003 to target portal *192.168.23.42 0003260 Root\ISCSIPRT\0000_0 . Log Name: System Source: iScsiPrt Event ID: 1 Level: Error Description: Initiator failed to connect to the target. Target IP address and TCP Port number are given in dump data. Log Name: System Source: iScsiPrt Event ID: 70 Level: Error Description: Error occurred when processing iSCSI logon request. The request was not retried. Error status is given in the dump data. So far that's expected beahvior, so I removed the portal from the iSCSI Initiator as described in MSKB 976072. However, the errors/warnings keep appearing every hour, even though neither iSCSI Initiator GUI nor iscscli show any portals: C:\>iscsicli ListTargetPortals Microsoft iSCSI Initiator Version 6.1 Build 7601 The operation completed successfully. The problem persists after rebooting the server. Uninstalling the Microsoft iSCSI Initiator device via devmgmt.msc as well as changing the Initiator parameters like this: [HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}] "MaxPendingRequests"=dword:00000001 "MaxConnectionRetries"=dword:00000001 "MaxRequestHoldTime"=dword:00000005 didn't help either. Each change was followed by a reboot. Disabling the device does prevent the errors/warnings from re-appearing, of course, but I'd rather not have to resort to this. How can I prevent those errors and warnings from appearing (short of disabling the initiator device or re-installing the server)? What am I missing? Environment: The virtual machine runs on a Hyper-V cluster managed by SCVMM 2012. Hosts and guests run Windows Server 2008 R2 SP1. The physical machines are Dell PowerEdge M710HD blades.

    Read the article

  • KVM recommendations

    - by alex
    I recently tried out a cheaper KVM solution, a dual monitor one with a USB hub and audio/mic support. It seemed the perfect KVM. However, these are my experiences. When using my keyboard via the PS/2 connection, none of my multimedia keys work (useful, because it has a volume control and my speakers do not, only on a wireless remote control.) I plugged the keyboard in via the USB port - and it seemed to work. However, I believe to switch the hub from PC to Mac, you need to use a keyboard combo, which is only supported when the keyboard is plugged in via PS/2 Sometimes the middle mouse button doesn't work when connected via PS/2. The multi monitor is VGA - I just found out by the looks of things my Mac Mini outputs DVI Digital only (though this is my fault!). Mac works with 2 screens, but switching and switching back can cause it not to display on the 2nd screen unless I go detect displays again. My question is - is there a KVM out there that supports these features? USB keyboard and mouse inputs will full multimedia keys support Dual monitor DVI connections Hotkey to change PCs and physical button USB hub Emulate screens attached when switching to a different computer Works with PC and Mac Audio / Microphone support Does one exist, that won't cost the world? So far the only one that seems to support all this (that I can tell) is this one. UPDATE I ended up buying the Aten CS1642. It's expensive, but it seems to work great!

    Read the article

  • Access All VLANS over XenServer Interface

    - by Garrett
    For my current setup, I have a physical NIC on a XenServer machine that receives traffic tagged with various VLAN IDs. I have a virtual machine that is running Vyatta that needs to be able to access both tagged and untagged traffic in order to route traffic. Here's the problem: 1) If I bind the NIC in XenCenter to the VM (which has no VLAN ID associated with it), the VM cannot see any tagged traffic. I have verified this using tcpdump. However, the tagged traffic is flowing into the XenServer machine perfectly fine. 2) I have more than 7 VLANs, so adding each VLAN as an interface within XenCenter isn't an option. 3) Even though tcpdump shows no tagged traffic coming in the VMs NIC, I have tried adding VLAN interfaces within Vyatta. This also doesn't work. I have tried using both Linux bridge and openvswitch setups and neither seem to work. I am running XenServer 6.0.3 free and Vyatta VC6.3. Please help! I've run out of ideas. I've googled for hours and can't seem to find anything.

    Read the article

  • Simple P2V help from Linux to Windows

    - by Ke.
    I have two OS's installed on different drives in my PC. One linux (Centos 5.4) and one windows 7. Its getting tiresome to constantly have to stop and restart the PC when I want to use either OS. I would very much like to use Windows 7 as my host OS and access my linux OS from within Windows. However, im having trouble deciphering exactly how to do this (many of the articles seem confusing and a bit overkill) From what i have seen its possible to use VMWare converter to convert the physical linux image to a virtual image so that I can use it in windows. As im having problems understanding how this is done, I would really appreciate a step by step guide (for a newbie), or any simple tutorials that you can point me at. Some questions beforehand: 1) My linux image is around 80gb, do i need to take this into consideration? The linux drive is around 180gb in total. All my other drives are NTFS non writeable in linux (as I use them in windows and ntfs is dodgy in linux), so probably not possible to move the image over to my ntfs drives 2) Can I just zip the linux files up somehow and transfer it to windows to create the p2v? 3) Is it possible to do the P2V conversion while I am logged into windows. I can see the actual linux drive loaded in disk manager, but windows doesnt read linux file systems so im confused as to how to access the linux drive if this is possible. 4) Or will i need to do the whole p2v conversion inside linux? Cheers, any help is much appreciated Ke (a confused p2v newbie)

    Read the article

  • How to update-grub on a system running overlayroot?

    - by mikepurvis
    We ship boxes configured with overlayroot, using the following overlayroot.conf: overlayroot=device:dev=/dev/sda6,timeout=20,recurse=0 Which produces the following mount configuration: $ mount overlayroot on / type overlayfs (rw,errors=remount-ro) /dev/sda5 on /media/root-ro type ext3 (ro,relatime,errors=continue,user_xattr,acl,barrier=1,data=ordered) /dev/sda6 on /media/root-rw type ext3 (rw,relatime,errors=continue,user_xattr,acl,barrier=1,data=ordered) /dev/sda1 on /boot type ext3 (rw) As you can see, three key physical partitions: sda1 is /boot, sda5 is a read-only "factory" root, and sda6 is a "user" root which can be wiped at any point to restore the machine to its original factory state. Now, the problem arises when update-grub is run for any reason: $ sudo update-grub [sudo] password for administrator: /usr/sbin/grub-probe: error: cannot find a device for / (is /dev mounted?). Understandable, since / is an overlayfs. The contents of /usr/sbin/update-grub are: #!/bin/sh set -e exec grub-mkconfig -o /boot/grub/grub.cfg "$@" With /usr/sbin/grub-mkconfig being the business part of things. But the actual problem is in /usr/sbin/grub-probe, called by grub-mkconfig, and grub-probe is a binary. So my question is, is there a parameter or whatever which can make grub-probe do the right thing in the face of / being an overlayfs? And secondly, is there a way to hack/patch that in so that the update-grub script just does the right thing? Thanks.

    Read the article

  • Outgrew MongoDB … now what?

    - by samsmith
    We dump debug and transaction logs into mongodb. We really like mongodb because: Blazing insert perf document oriented Ability to let the engine drop inserts when needed for performance But there is this big problem with mongodb: The index must fit in physical RAM. In practice, this limits us to 80-150gb of raw data (we currently run on a system with 16gb RAM). Sooooo, for us to have 500gb or a tb of data, we would need 50gb or 80gb of RAM. Yes, I know this is possible. We can add servers and use mongo sharding. We can buy a special server box that can take 100 or 200 gb of RAM, but this is the tail wagging the dog! We could spend boucoup $$$ on hardware to run FOSS, when SQL Server Express can handle WAY more data on WAY less hardware than Mongo (SQL Server does not meet our architectural desires, or we would use it!) We are not going to spend huge $ on hardware here, because it is necessary only because of the Mongo architecture, not because of the inherent processing/storage needs. (And sharding? Please! Cost aside, who needs the ongoing complexity of three, five, or more servers to manage a relatively small load?) Bottom line: MongoDB is FOSS, but we gotta spend $$$$$$$ on hardware to run it? We sould rather buy commercial SW! I am sure we are not the first to hit this issue, so we ask the community: Where do we go next? (We already run Mongo v2) Thanks!!

    Read the article

  • RAID 5 - DELL 2850 and others

    - by Kiara
    I have installed Ubuntu on a DELL 2850 and I have configured an array of 5 disks (SCSI 73GB 10K) in RAID5. I wanted to simulate a drive error so in the middle of something I just took one of the drives out and put it back again after a bit. Then the drive shows an orange light and seems to be rebuilding but actually is taking hours and hours with no results. So I went to the PERC utility (Ctrl+M) and the disk shows "REBLD". But it never gets to an online state. So I went to Objects - Physical drives - Rebuilding - View rebuild process. And in here I can see a bar moving from 0%... but if I reboot before finishing and get into the PERC Utility again, it seems to start again rebuilding from 0% - so it is not rebuilding automatically. My concern is: what would happen in a real situation? Do I have to just switch the server off and go to the Perc utility to start the rebuilding manually? I thought the whole point was to have this done automatically and without the need of stopping the server. Or does it perhaps rebuild automatically indeed but needs to have enough time without rebooting because otherwise the rebuilding process will start from scratch? It seems to take more than 3h for a 73gb disk! My second question is: can I mix then hard drives? So if I have a RAID of 5x73GB 10K can I use different size (146GB) or speeds (15K)? Apparently someone said it is OK in here Poweredge 2850: replace disk with larger in RAID?

    Read the article

  • USB Hardware vs. Software Write Lock

    - by TreyK
    I'm in the market for a USB flash drive, and remember this cool feature a tiny 32MB flash drive of mine had: a write lock switch. This seemed like it would be an amazing feature to have as a shield against any nastiness happening to the drive on an unfamiliar computer. However, very few drives on the market offer this feature. Instead, it seems that forms of software protection are the more prominent method. This software protection causes me a bit of uneasiness, as it seems like this software wouldn't be nearly as bulletproof as a physical switch. Also, levels of protection seem to vary from product to product. Being able to protect certain folders from reading and/or writing would be nice, but is the security trade-off worth it? Just how effective can this software protection be? Wouldn't a simple format be able to clean any drive with software protection? My drive must also be compatible with Windows XP, Vista, and 7, as well as Linux and Mac. What would be the best way forward for getting a well-sized (~8GB) flash drive with a strong write protection implementation, for little or no more than a regular drive? Thanks.

    Read the article

  • How can I fix my corrupted RAID1 ext4 partition on a Synology DS212 NAS?

    - by Neil
    I have two identical 3 TB disks that were in a RAID1 array, where one disk crashed. I replaced the failed disk, but not after the RAID partitions got messed up. I need to figure out how to restore the RAID array and get at my ext4 partition. Here are the properties of the surviving disk: # fdisk -l /dev/sda fdisk: device has more than 2^32 sectors, can't use all of them Disk /dev/sda: 2199.0 GB, 2199023255040 bytes 255 heads, 63 sectors/track, 267349 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/sda1 1 267350 2147483647+ ee EFI GPT # parted /dev/sda print Model: ATA ST3000DM001-9YN1 (scsi) Disk /dev/sda: 3001GB Sector size (logical/physical): 512B/512B Partition Table: gpt Disk Flags: Number Start End Size File system Name Flags 1 131kB 2550MB 2550MB ext4 raid 2 2550MB 4698MB 2147MB linux-swap(v1) raid 5 4840MB 3001GB 2996GB raid I replaced the failed drive, and cloned the surviving drive to it so I have something to work with. I cloned the drives with dd if=/dev/sdb of=/dev/sda conv=noerror bs=64M, and now /dev/sda and /dev/sdb are identical. Here is the RAID information: # cat /proc/mdstat Personalities : [linear] [raid0] [raid1] [raid10] [raid6] [raid5] [raid4] md1 : active raid1 sdb2[1] 2097088 blocks [2/1] [_U] md0 : active raid1 sdb1[1] 2490176 blocks [2/1] [_U] unused devices: <none> It seems that md2 is missing. Here is what testdisk 6.14-WIP finds: Disk /dev/sda - 3000 GB / 2794 GiB - CHS 364801 255 63 Current partition structure: Partition Start End Size in sectors 1 P Linux Raid 256 4980735 4980480 [md0] 2 P Linux Raid 4980736 9175039 4194304 [md1] Invalid RAID superblock 5 P Linux Raid 9453280 5860519007 5851065728 5 P Linux Raid 9453280 5860519007 5851065728 # After a quick search Disk /dev/sda - 3000 GB / 2794 GiB - CHS 364801 255 63 Partition Start End Size in sectors D MS Data 256 4980607 4980352 [1.41.12-2197] D Linux Raid 256 4980735 4980480 [md0] D Linux Swap 4980736 9174895 4194160 D Linux Raid 4980736 9175039 4194304 [md1] >P MS Data 9481056 5858437983 5848956928 [1.41.12-2228] And listing the files on the last partition in the list shows all of my files intact. What should I do?

    Read the article

  • How to get decent WiFi despite a virtual Faraday cage

    - by MT_Head
    One of my clients is the local branch of an international airline. They have a small office in the secured area behind the ticket counters, and timeshare space at the ticket counter. I need to add a ticket printer out front, which I cannot (for contract/liability reasons) attach to the shared computer at the counter; the only workable solution seems to be to put the printer and its attached computer on a cart and connect to the office's network via WiFi. So far, no problem - right? Well, the terminal has been getting a facelift, which - among other things - includes decorative stainless-steel panels along the wall behind the ticket counters. This paneling acts as a seriously effective barrier to WiFi! The office's WiFi router - a brand-new D-Link DIR-815, dual-band 802.11n - is just on the other side of the pictured wall, and twenty feet or so to the right. And yet the only way I can connect AT ALL on this side of the wall is to stick the USB adapter (on the end of an extension cable) right into the crack between panels... and even then I can only see the 5GHz network, and that very weakly. Has anyone else had experience with this sort of misguided interior decoration? Any ideas on how I can improve reception on the other side of the barrier? (Needless to say, physical modifications of the environment - tempting though they might be - are strictly no-go.)

    Read the article

  • External Hard Drive Won't Mount - MAC OSX

    - by dtj
    I have a Western Digital hard drive that's about 4 or 5 years old. It's 500 GB, USB. I use it to backup my Mac every so often. I had it partitioned: 1 side for full backups, and the other side for general storage of music, installers, etc. I decided to get rid of the partition today and dump all the data. So I opened disk utility, and hit 'erase'. It started thinking and then disk utility crashed. After the crash, the hard drive won't mount, however disk utility still sees the drive, but not the individual volume within. I tried booting up Disk Warrior and no luck there either. It has the drive as an "unknown drive". When I hit rebuild, it goes through all it steps and then stops cause of this error: The drive "unknown" is severely damaged and DiskWarrior is unable to determine its case sensitivity What can I do at this point? There isn't any physical damage to the drive. Never been dropped or anything.

    Read the article

  • Powershell Win32_NetworkAdapterConfiguration Not "seeing" PPP Adapter

    - by Ben
    I am trying to get the IP of a PPP VPN network connection, but Win32_NetworkAdapterConfiguration does not seem to "see" it. If I interrogate all adapters using my script, it will see everything but the PPP VPN adapter. Is there a specific filter or something I need to enable, or do I need a different class? My Script: $colItems = Get-wmiobject Win32_NetworkAdapterConfiguration foreach ($objItem in $colItems) { Write-Host Description: $objItem.Description Write-Host IP Address: $objItem.IPAddress Write-Host "" } Script Output: Description: WAN Miniport (SSTP) IP Address: Description: WAN Miniport (IKEv2) IP Address: Description: WAN Miniport (L2TP) IP Address: Description: WAN Miniport (PPTP) IP Address: Description: WAN Miniport (PPPOE) IP Address: Description: WAN Miniport (IPv6) IP Address: Description: WAN Miniport (Network Monitor) IP Address: Description: Intel(R) PRO/Wireless 3945ABG Network Connection IP Address: 192.168.2.5 Description: WAN Miniport (IP) IP Address: ipconfig /all output: PPP adapter My VPN: Connection-specific DNS Suffix . : Description . . . . . . . . . . . : My VPN Physical Address. . . . . . . . . : DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes IPv4 Address. . . . . . . . . . . : 10.1.8.12(Preferred) Subnet Mask . . . . . . . . . . . : 255.255.255.255 Default Gateway . . . . . . . . . : 0.0.0.0 DNS Servers . . . . . . . . . . . : 10.1.1.3 10.1.1.2 Primary WINS Server . . . . . . . : 10.1.1.2 Secondary WINS Server . . . . . . : 10.1.1.3 NetBIOS over Tcpip. . . . . . . . : Enabled Wireless LAN adapter Wireless Network Connection: Connection-specific DNS Suffix . : Belkin Description . . . . . . . . . . . : Intel(R) PRO/Wireless 3945ABG Network Connection Physical Address. . . . . . . . . : 00-3F-3C-22-22-22 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes IPv4 Address. . . . . . . . . . . : 192.168.2.5(Preferred) Subnet Mask . . . . . . . . . . . : 255.255.255.0 Lease Obtained. . . . . . . . . . : 25 May 2010 20:33:19 Lease Expires . . . . . . . . . . : 22 May 2020 20:33:17 Default Gateway . . . . . . . . . : 192.168.2.1 DHCP Server . . . . . . . . . . . : 192.168.2.1 DNS Servers . . . . . . . . . . . : 192.168.2.1 NetBIOS over Tcpip. . . . . . . . : Enabled Thanks in advance, Ben

    Read the article

  • mdadm superblock hiding/shadowing partition

    - by Kjell Andreassen
    Short version: Is it safe to do mdadm --zero-superblock /dev/sdd on a disk with a partition (dev/sdd1), filesystem and data? Will the partition be mountable and the data still there? Longer version: I used to have a raid6 array but decided to dismantle it. The disks from the array are now used as non-raid disks. The superblocks were cleared: sudo mdadm --zero-superblock /dev/sdd The disks were repartitioned with fdisk and filesystems created with mfks.ext4. All disks where mounted and everything worked fine. Today, a couple of weeks later, one of the disks is failing to be recognized when trying to mount it, or rather the single partition on it. sudo mount /dev/sdd1 /mnt/tmp mount: special device /dev/sdd1 does not exist fdisk claims there to be a partition on it: sudo fdisk -l /dev/sdd Disk /dev/sdd: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0xb06f6341 Device Boot Start End Blocks Id System /dev/sdd1 1 243201 1953512001 83 Linux Of course mount is right, the device /dev/sdd1 is not there, I'm guessing udev did not create it because of the mdadm data still on it: sudo mdadm --examine /dev/sdd /dev/sdd: Magic : a92b4efc Version : 1.2 Feature Map : 0x0 Array UUID : b164e513:c0584be1:3cc53326:48691084 Name : pringle:0 (local to host pringle) Creation Time : Sat Jun 16 21:37:14 2012 Raid Level : raid6 Raid Devices : 6 Avail Dev Size : 3907027120 (1863.02 GiB 2000.40 GB) Array Size : 15628107776 (7452.06 GiB 8001.59 GB) Used Dev Size : 3907026944 (1863.02 GiB 2000.40 GB) Data Offset : 2048 sectors Super Offset : 8 sectors State : clean Device UUID : 3ccaeb5b:843531e4:87bf1224:382c16e2 Update Time : Sun Aug 12 22:20:39 2012 Checksum : 4c329db0 - correct Events : 1238535 Layout : left-symmetric Chunk Size : 512K Device Role : Active device 3 Array State : AA.AAA ('A' == active, '.' == missing) My mdadm --zero-superblock apparently didn't work. Can I safely try it again without losing data? If not, are there any suggestion on what do to? Not starting mdadm at all on boot might be a (somewhat unsatisfactory) solution.

    Read the article

  • SQL Server slow in production environment

    - by Lieven Cardoen
    I have a weird problem in a customer's production environment. I can't give any details on the infrastructure, except that SQL server runs on a virtual server. The data, log and filestream file are on another storage server (data and filestream together and log on a separate server). In our local Test environment, there's one particular query that executes with these durations: first we clear the cache 300ms (First time it takes longer, but from then on it's cached.) 20ms 15ms 17ms In the customer's production environment, the SQL Server is more powerful, these are the durations (I didn't have the rights to clear the cache. Will try this tomorrow). 2500ms 2600ms 2400ms The servers in the customer's production environment are more powerful but they do have virtual servers (we don't). What could be the cause... Not enough memory? Fragmentation? Physical storage? How would you tackle this performance problem? EDIT: Some people have asked me if the data set is equal and it is. I restored their database on our environment. It's true that this was the first thing I looked at. (@Everyone: I added the edit because it will be the first thing that many will think off).

    Read the article

  • How to configure Hyper-V failover cluster to live migrate when dynamic memory runs out?

    - by Matt Johnson
    Appologies in advance that this is not a direct programming question, but I have a feeling that the solution involves custom powershell scripts (maybe), so this is as good a place to ask as any. I maintain a website that has a large Hyper-V cluster for SQL Servers. We are using Windows 2008 R2 SP1, and the new "dynamic memory" feature. I've already ready reviewed the Best Practices Guide, and implemented it's suggested configuration. Everything works well, except that when SQL demand increases memory pressure to expand to more memory than is available on the physical machine, the memory status goes into the "Warning" state and stays there. I assume the hypervisor is using a swapfile on the host to fulfill the memory requirement, thus slowing the virtual machine down. When this happens, there are plenty of other nodes in the cluster that have available resources. I can live-migrate the virtual server over there and everything works, and the warnings go away. Now how can I automate this? I see no menu options in either Hyper-V or the Failover Cluster Manager for performing a migration or shutdown when dynamic memory goes into the warning state. Any ideas about how to script this, or monitor it and invoke the action directly, would be helpful. If the solution involves coding, powershell would be ideal, but I could envison this as a .Net Service that monitors for this state and kicks off the migration request. I just don't know what objects are involved in doing the monitoring or kicking off the live migration. Thanks in advance.

    Read the article

  • Cisco SG200 vlan issue in ESXi VSA cluster

    - by George
    I have three Cisco SG200-26 switches, and I also have two ESXi hosts that I have connected like shown in the below "best practice" map by VMware: http://communities.vmware.com/servlet/JiveServlet/previewBody/17393-102-1-22458/VSA_networking_map.pdf Even though I created the VLANs in the SG200 and I set the two VLANs (508 and 608) as allowed for these untagged ports (where my ESX NIC's are connected), I can not ping from host 1 to host 2 when configuring the NIC's to use 608 VLAN. Am I missing something? my IP's are all in the 192.168. range, and the only reason I need the VLANs is to isolate the traffic of VSA back-end internally, only the two hosts will be using the VLANs. So I think I do not have to create virtual interfaces on my router since that's the case, is my understanding correct? Also sending my switch config screenshot below.. all 3 switches have the latest firmware (it seems these were originally linksys and got rebranded as cisco after the acquisition) http://img31.imageshack.us/img31/2503/switch.gif Any ideas what to change on the Cisco SG200 to make this work , would be appreciated! The second VLAN (608) only needs two IP's: 192.168.0.1 and 192.168.0.2 The first VLAN (508) will have about 15 IP's for ESXi Management and VSA cluster service, I could use either 192.168.1.xx or 10.0.1.xx The rest of my network (about 50 clients) is in 192.168.1.xx range VMware also states that the VLAN protocol on the physical switch must be 802.1Q, not ISL, anyone knows which of the two my SG200-26 uses? In addition to that, the only requirement from VSA is that my two hosts: -Are in the same subnet. -Have static IP addresses set. -Have the same Default Gateway configured. If I need inter-vlan routing for this, I suppose I have to create virtual interfaces on my sonicwall, and assign an IP for each VLAN, and then set routes between them? Thank you for your time!

    Read the article

  • Low CPU performance with low usage and clock - Windows 8.1

    - by Daniele
    I recently deleted everything from my PC and reinstalled Windows 8.1 from scratch. When I first booted into Windows everything was extremely slow though the CPU usage was very low (about 1%). After installing some drivers the problem seemed to be solved, I was able to use my PC normally. Today I installed a game and I noticed a strange behavior: the game was playable but the performance worsened more and more in the time. This is the situation BEFORE opening the game (normal): This is AFTER some minutes inside the game (low CPU usage and clock): Some information about my system: PC: Sony Vaio S13 (SVS13A1C5E) OS: Windows 8.1 CPU: Intel Core i7-3520M 2.90GHz GPU(1): Intel HD Graphics 4000 GPU(2): NVIDIA GeForce GT 640M LE I tried searching for new drivers and other solutions but noting worked and I don't know what is the cause. I did not checked the temperatures but the fans are not running fast and the PC does not look overheated. Update: Max CPU Temp: 66°C, Max GPU Temp: 61°C The strange thing is that the GPU load is 99% (GPU-Z) and the fan is almost silent. Update 2: I had troubles with Sony Vaio software, I can't get the FN keys and the STAMINA/SPEED switch to work (it is a physical switch to enable/disable the Nvidia card and change the Power Profile). I'm saying this because I remember that before reinstalling Windows there was an option in the Vaio Control Center (now it is not there anymore) that allowed me to choose from something like "priority to performance (ventilation)" or "priority to silence". The current behavior looks like a "priority to silence", but I can't get the stamina-speed switch to work and so I don't see similar oprions in the Vaio Control Center. I don't know if the problem is related to this.

    Read the article

  • I cannot format my PC

    - by Jesus Buelna
    I have a Toshiba Satellite(1) l505 6gb RAM, 6.00GB hard disk.Initially I have problem with another satellite(2) I had (mother board problem). I took my Laptop to a technician and cost a lot of money (almost as much as buying new one). So, since I have HDD problems with the first one(1) I decided to use the hard disk of the other one(2). I formatted the HDD and erased the partitions it had into 1 partition (or no partition). The problem is that when I try to format with the SO CD, in the screen, where I have to decide in which partition I want to install the SO, the only one option I have says "unallocated partition and I receive this message "Windows cannot install the SO in this partition, run files do not existed or maybe corrupted" When I erased the disk with Parted Magic, Did I erased any files needed for running the installing disk? I don't know. Is it possible to fixed or reinstate the disk to install the OS? By the way, I checked the disk physical health with Parted Magic, and it is OK. One more thing when I erased the disc to 0, I used the safety option offered by the Parted Magic.Need help please.

    Read the article

  • Will this increase my Virtual private Server failing rate ?

    - by Spencer Lim
    Will this increase my Virtual private Server failing rate if i :- install Microsoft Window Server 2008 Enterprise install SQL server enterprise 2008 install IIS 7.5 install ASP.Net Mvc 2 install Microsoft Exchange << should live inside MWS2008 ? or standalone without OS? install Team foundation server << should live inside MWS2008 ? or standalone without OS? on one mini VPS with specification of DELL Poweredge R710 shared plan DDR3 ECC RAMs 16GB and -- 1GB for this VPS using DELL PERC 6i raid controller (this thing alone about 1.5k-2k) and the SAS HDD (15K RPM) (146GB) -- 33GB to this VPS each hdd is freaking fast over 300MB read / write possible with proper tuning the motherboard is a DELL and it has twin redundant PSU (870watt 85%eff) its running on Intel Xeon 5502 (Quad Core) x2 so about 8 physical proc (fairly share) is there any ruler to measure for this about one VPS can only install what what what service ? because of my resource is limited =.@ may i know if it is install in this way,maybe it seem like defeat the way of "VPS"... what will happen ? or any guideline on this issue (fully configuring the window server 2008 R2) ? Thx for reply

    Read the article

  • Limit Apache 2 Memory Usage

    - by UltraNurd
    I am running a hobby webserver off of an ancient Blue & White G3/300 running Debian PPC Squeeze 2.6.30. The performance is okay for a while after a restart, but it eventually gets more and more bogged down. Right now it's at 76 days uptime, and the main culprit seems to be the memory usage of 10+ apache2 processes. I think I need to lower the values for StartServers, MinSpareServers, and/or MaxSpareServers, but I'm not sure which one to adjust, and there are three sections for each depending on which mpm module is in use. How do I tell which of the following sections I need to change, and what are some reasonable values given that the box has 448 MB physical memory (weird upgrade history of one each 64, 128, and 256 sticks)? <IfModule mpm_prefork_module> StartServers 5 MinSpareServers 5 MaxSpareServers 10 MaxClients 150 MaxRequestsPerChild 0 </IfModule> <IfModule mpm_worker_module> StartServers 2 MinSpareThreads 25 MaxSpareThreads 75 ThreadLimit 64 ThreadsPerChild 25 MaxClients 150 MaxRequestsPerChild 0 </IfModule> <IfModule mpm_event_module> StartServers 2 MaxClients 150 MinSpareThreads 25 MaxSpareThreads 75 ThreadLimit 64 ThreadsPerChild 25 MaxRequestsPerChild 0 </IfModule> There aren't any other instances of StartServers in my apache2.conf, but none of those mpm modules appear in mods-available or mods-enabled. Ideas? Thanks!

    Read the article

  • Windows Terminal Server: occasional memory violation for applications

    - by syneticon-dj
    On a virtualized (ESXi 4.1) Windows Server 2008 SP2 32-bit machine which is used as a terminal server, I occasionally (approximately 1-3 event log entries a day) see applications fail with an 0xc0000005 error - apparently a memory access violation. The problem seems quite random and only badly reproducable - applications may run for hours, fail with 0xc0000005 and restart quite fine or just throw the access violation at startup and start flawlessly at the second attempt. The names of executables, modules and offset addresses vary, although a single executable tends to fail with same modules and the same memory offset addresses (like "OUTLOOK.EXE" repeatedly failing on module "olmapi32.dll" with the offset "0x00044b7a") - even across multiple user's logons and with several days passing without a single failure inbetween. The offset addresses seem to change across reboots, however. Only selective executables seem affected by the problem, although I may simply not be seeing a sufficient number of application runs from the other ones. I first suspected a possible problem with the physical machine's RAM, but ruled this out as a rather unlikely cause - the memory comes with ECC and I've already moved the virtual machine across several times, without any perceptable change. I've seen that DEP was enabled in "OptOut" mode on this machine: C:\Users\administrator>wmic OS Get DataExecutionPrevention_SupportPolicy DataExecutionPrevention_SupportPolicy 3 and tried changing the policy to OptIn via startup options: bcdedit.exe /set {current} nx OptIn but have yet to see any effect - I also would expect Outlook 12 or Adobe Reader 9 (both affected applications) to play well with DEP. Any other ideas why the apps may be failing?

    Read the article

  • Memory leak in Google Chrome

    - by jasondavis
    As a developer it is very common for me to have 2-3 different IDE's open, 10-15 google chrome windows which can hold up to 200 open tabs (I know I get out of hand some times), Photoshop, couple twitter bots for promo, and a few other programs but my system still runs fast and smooth. I have an i7 processor with 12gb ram. Now with all my usual stuff running my Physical memory is usually running around 50-60% however over the course of the day or much less even, I will gradually grow to 98% The highest Memory usage processes will be from Google Chrome, if I sort in the task manager by highest memory usage and end the 1 highest process which will be a google chrome one, my memory usage will jump back down to about 60%. Also by ending that 1 process, all my Chrome windows will remain open and in use, so it doesn't affect me at all by ending that process. Based on this research I am assuming that that 1 runaway process is likely the Adobe Flash as I also can say that it gets up to the 98% much faster when I am using flash items like video or music player. But even without using any of them it will still climb up to that high number eventually. Has anyone else experienced similar results?

    Read the article

  • 0x0000007b WinXP in VirtualBox with no Admin access on source drive

    - by Ozzah
    I have a physical drive with an installation of WinXP-32 which I have made a clone of using SysInternals disk2vhd. I have no admin rights on this installation. I have tried to boot this VHD in VirtualBox, however it blue screens on 0x0000007b. I have researched this and apparently the cause is that Windows doesn't like the IDE controller changing. I have tried all the available controllers in VirtualBox, but they all produce the same result. There is a Microsoft KB article which describes a method involving loading a .reg file and extracting some sys files from a CAB. This method apparently works well for many people with this problem, however it will not work for me as I don't have admin rights on the WinXP installation. Is there anything I can do in this case? Is there any way of loading the .reg file outside the OS? or perhaps doing a repair using the WinXP CD? Even though I have no admin rights on the source drive installation of Windows, I do obviously have full access to the file system directly on the drive and also in the VHD itself.

    Read the article

< Previous Page | 97 98 99 100 101 102 103 104 105 106 107 108  | Next Page >