Search Results

Search found 2827 results on 114 pages for 'suggestion'.

Page 102/114 | < Previous Page | 98 99 100 101 102 103 104 105 106 107 108 109  | Next Page >

  • Exchange IMAP4 connector - Error Event ID 2006

    - by MikeB
    Hi, A couple of users in my organisation use IMAP4 to connect to Exchange 2007 (Update rollup 9 applied) because they prefer Thunderbird / Postbox clients. One of the users is generating errors in the Application Log as follows: An exception Microsoft.Exchange.Data.Storage.ConversionFailedException occurred while converting message Imap4Message 1523, user "*******", folder *********, subject: "******", date: "*******" into MIME format. Microsoft.Exchange.Data.Storage.ConversionFailedException: Message content has become corrupted. ---> System.ArgumentException: Value should be a valid content type in the form 'token/token' Parameter name: value at Microsoft.Exchange.Data.Mime.ContentTypeHeader.set_Value(String value) at Microsoft.Exchange.Data.Storage.MimeStreamWriter.WriteHeader(HeaderId type, String data) at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimeStreamAttachment(StreamAttachmentBase attachment, MimeFlags flags) --- End of inner exception stack trace --- at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimeStreamAttachment(StreamAttachmentBase attachment, MimeFlags flags) at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimeAttachment(MimePartInfo part, MimeFlags flags) at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimePart(MimePartInfo part, MimeFlags mimeFlags) at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimeParts(List`1 parts, MimeFlags mimeFlags) at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimePart(MimePartInfo part, MimeFlags mimeFlags) at Microsoft.Exchange.Data.Storage.ImapItemConverter.<>c__DisplayClass2.<WriteMimePart>b__0() at Microsoft.Exchange.Data.Storage.ConvertUtils.CallCts(Trace tracer, String methodName, String exceptionString, CtsCall ctsCall) at Microsoft.Exchange.Data.Storage.ImapItemConverter.WriteMimePart(ItemToMimeConverter converter, MimeStreamWriter writer, OutboundConversionOptions options, MimePartInfo partInfo, MimeFlags conversionFlags) at Microsoft.Exchange.Data.Storage.ImapItemConverter.GetBody(Stream outStream) at Microsoft.Exchange.Data.Storage.ImapItemConverter.GetBody(Stream outStream, UInt32[] indices) From my reading around it seems that the suggestion is to ask users to log in to Outlook / OWA and view the messages there. However, having logged in as the users myself, the messages cannot be found either through searching or by browsing the folder detailed in the log entry. The server returns the following error to the client: "The message could not be retrieved using the IMAP4 protocol. The message has not been deleted and may be accessible using either Microsoft Outlook or Microsoft Office Outlook Web Access. You can also try contacting the original sender of the message to find out about the contents of the message. Retrieval of this message will be retried when the server is updated with a fix that addresses the problem." Messages were transferred in to Exchange by copying them from the old Apple Xserve, accessed using IMAP. So my question, finally: 1. Is there any way to get the IMAP Exchange connector to rebuild its cache of messages since it doesn't seem to be pulling them directly from the MAPI store? 2. Alternatively, if there is no database, any ideas on why these messages don't appear in Outlook or OWA would be gratefully received. Many thanks, Mike

    Read the article

  • How can I change how OS X's 'say' command pronounces a word?

    - by jwhitlock
    OS X's say command is useful for some tasks (such as Skype's 'notify me when a contact comes online), but it is pronouncing some names incorrectly. Is there a way to teach say to pronounce a word differently? For example, try: say "Hi, Joel Spolsky" The 'ol' sounds like 'ball' rather than 'old'. I'd like to add an exception that say "Pronounce Spolsky like this", rather than try to teach new linguistic rules. I bet there is a way since it can pronounce "iphone" as Apple wants. Update - After some research, here's what I've learned: Text-to-speech is split between turning the text to phonemes, and then the phonemes are turned into audio using a voice. Changing the voice doesn't effect the phonemes. The Speech Synthesis Manager has some functions for turning text to phonemes, and a method for registering a speech dictionary that will add new text-phoneme maps. However, Apple's speech dictionary must be in a binary form - I didn't find any plist XML. Using dtrace while running say, I found some interesting files opened in /System/Library/PrivateFrameworks/SpeechDictionary.framework/Resources. This is probably the speech dictionary, but they are all binary, except for Homophones, which is XML. Adding entries to Homophones does nothing - it is probably used in speech-to-text. They are also code signed by Apple - changing them may prevent some programs from working. PrefixDictionary CartNames CartLite SymbolDictionary Homophones There are ways to add text versions of application interface elements so VoiceOver works, a lot of which a developer gets for free, but there are tricky bits. The standard here appears to be to use a phonetic spelling as needed. My guesses are: say is a light layer of code on top of the Speech Synthesis Manager. It would be easy for the Apple devs to add a command line option to take the path to a speech dictionary plist for alternate phoneme mapping, but they didn't. It may be a useful open-source project to write a better say. Skype probably uses Speech Synthesis Manager directly, leaving no hooks to change the way my friend's names are pronounced, other than spelling them phonetically, which is silly. The easiest way to make a command line version of say is how JRobert suggested. Here's my quick implementation, using Doug Harris's spelling suggestion: #!/bin/sh echo $@ | tr '[A-Z]' '[a-z]' | sed "s/spolsky/spowlsky/g" | /usr/bin/say Finally, some fun command line stuff: # Apple is weird sqlite3 /System/Library/PrivateFrameworks/SpeechDictionary.framework/Resources/Tuples .dump # Get too much information about what files are being opened sudo dtrace -n 'syscall::open*:entry { printf("%s %s",execname,copyinstr(arg0)); }' # Just fun say -v bad "Joel Spolsky Spolsky Spolsky Spolsky Spolsky, Joel Spolsky Spolsky Spolsky Spolsky Spolsky" echo "scale=1000; 4*a(1)" | bc -l | say

    Read the article

  • What issues ensue from having multiple versions of Office installed?

    - by Michael Sorens
    My ultimate question is embodied in the title but I thought it might be helpful to others if I detail what instigated my inquiry and my examination of the problem. To me, the first rule of software updates is Primum non nocere -- first, do no harm. So with my Windows 7 system containing both Office 2003 and Office 2010 I blithely proceeded to install this month's updates from Microsoft, containing updates for both versions of Office. While Microsoft officially does not recommend running multiple versions (see, for example, Running Multiple Versions of Microsoft Excel it is possible; I have had two versions installed for a year or more and have never run into an issue before. One thing that is always mentioned is installation order, i.e., the one you want to open files by default should be installed last. I wanted 2010 as my default so I had indeed installed 2003 first then, years later, 2010. So with this round of Windows updates, either it installed patches to 2010 before 2003, knocking out the file association, or the 2003 patch was more comprehensive, in the sense of touching the file association while the 2010 did not. In any case, after updates, double-clicking a .xls file opened 2003 rather than 2010. Web search indicated either: Use the file associations control panel to re-associate .xls files with the correct version of excel. I looked at this first, but it showed what seemed to be an unversioned "Excel" associated with .xls files so I did not check further. (This turned out to be an error on my part; more later.) Re-install versions in the desired order; I find this unreasonable. Run the repair option of the Office installer on the desired version; still seems more work than one should need. Run excel from the command line with "/regserver" on the one to be the default and "/unregserver" on the other. Good idea, but further search indicated that neither 2007 nor 2010 support "/regserver" contrary to some posts (e.g. Default Program With Multiple Versions Installed). Since this was a Windows Update issue and Microsoft provides free support for such, I inquired there as well, but succeeded only in getting the suggestion to uninstall all other versions, period; not acceptable to me. What worked for me was going back to the file associations control panel and manually selected the Office 2010 version of Excel. While it appeared no different in the control panel, it did fix the double-click issue. So if all it takes is this simple fix after an update, I can live with that. What I am wondering is: Has anyone seen any other problems related to having multiple versions of Office installed?

    Read the article

  • I want to virtualize my workstation (Tier 1), Looking for Bare Metal Hypervisor for consumer grade components

    - by Chase Florell
    I find myself in this similar bind at least once a year. The bind whereby I'm either upgrading a motherboard, or an OS hard drive. It drives me crazy to have to reinstall Windows, Visual Studio, all my addins, reconfigure my settings etc... every single time. I have a layout and I like and I want to stick with it. My question is... Is there a Bare Metal Hypervisor on the market that will enable me to virtualize my consumer grade workstation? I really want to avoid Host/Client virtualization. Bare Metal is definitely a better way to go for my needs. Is this a good approach, or am I going to suffer some other undesirable side effects by doing this? Clarification My machine has very limited purposes. My primary use is Visual Studio 2010 Professional where I develop ASP.NET MVC Web Applications. The second piece of software that I use (that's system intensive) is Photoshop CS3. Beyond that, my applications are limited to Outlook, Internet Explorer, Firefox, Opera, Chrome, LinqPad, and various other (small) apps. Beyond this, I'm considering working on a node.js project and might run ubuntu on the same hypervisor if possible. System Specs: Gigabyte Motherboard Intel i7 920 12 GB Ram basic 500GB 7200RPM HDD for OS 4 VelociRaptors in Raid 1/0 for build disk Dual GTS250 (512MB) Graphics cards (non SLI) for quad monitors On a side note I also wouldn't be opposed to an alternative suggestion if the limitations are too great. I could install the ESXi (or Zen Server) on my box, and build a separate "thin client" to RDP into the virtual machine. It appears as though RDP supports dual monitors. Edit (Dec 9, 2011) It's been nearly a year since I first asked this question. Since then, there have been a lot of great strides in Hypervisor technology... AND MokaFive is now released for corporate use. I'd love to dig into this question a little more and find out if there is a solid BareMetal Hypervisor for workstations running consumer grade components (IE: not Dell, HP, Lenovo, Etc).

    Read the article

  • Sycronizing/deploying scripts across several systems

    - by otto
    I have a few time consuming tasks that I like to spread across several computers. These tasks require running an identical ruby or python script (or series of scripts that call each other) on each machine. The machines will a separate config file telling the script what portion of the task to complete. I want to figure out the best way to syncronize the scripts on these machines prior to running them. Up until now, I have been making changes to a copy of the script on a network share and then copying a fresh copy to each machine when I want to run it. But this is cumbersome and leaves a chance for error ( e.g missing a file on the copy or not clicking "copy and replace"). Lets assume the systems are standard windows machines that are not dedicated to this task and I don't need to run these scripts all the time (so I don't want a solution that runs 24/7 and always keeps them up to date, I'd prefer something that pushes/pulls on command). My thoughts on various options: Simple adaptation of my current workflow: Keep the originals on the network drive, but write a batch file that copies over the latest version of the scripts so everything is a one-click operation. Requires action on each system, but that's not the end of the world (since each one usually needs their configuration file changed slightly too). Put everything in a Mercurial/Git reposotory and pull a fresh copy onto each node. Going straight to the repo from each machine would guarantee a current version (and would have the fringe benefit of allowing edits to the script to be made from any machine). Cons would be that it requires VCS to be installed on each machine and there might be some pains dealing with authentication since I wouldn't use a public repo. Open up write access on a shared folder and write a script to use rsync (or similar) to push the changes out to all of the machines at once. This gets a current version on every machine (though you would have to change the script if you want to omit a machine or add a new one). Possible issue would be that each computer has to allow write access. Dropbox is a reasonable suggestion (and could work well) but I dont want to use an external service and I'd prefer not to have to have dropbox running 24/7 on systems that would normally not need it. Is there something simple that I am missing? Some tool designed expressly for doing this kind of thing? Otherwise I am leaning toward just tying all of the systems into Mercurial since, while it requires extra software, it is a little more robust than writing a batch file (e.g. if I split part of a script into a separate module, Mercurial will know what to do whereas I would have to add a line to the batch file).

    Read the article

  • Exchange-Server Query

    - by Rudi Kershaw
    First, a little background. I've recently been taken on as a web and software developer for a small company, who has no other in-house IT support. They've been asking my opinion on lots of IT subjects that are quite far out of my comfort zone. I'm definitely not a network admin. Their IT consultancy contractor is pushing them to upgrade their dedicated exchange server, even though it seems like the one they currently have has a lot of life left in it and is running problem free. They say it's "coming to the natural end of it's life". They want to install a monster with a Xeon E5-2420, 32GB RAM, 2x 1TB HDDs, Windows Server 2012 and Microsoft Exchange 2010. They want to charge a small fortune for it. Basically, this system seems massively over the top seeing as it won't be doing anything else other than running as an exchange server for a company with less than 25 email accounts. My employers also have a file server system in-house that hosts three web apps, an SQL server, their local domain, print server and shared folders. That machine is using the same specs as the proposed new one, and it is barely using any of it's potential. I asked if Microsoft Exchange 2010 could be installed on their file server, but they said that MS Exchange can't run on the same system as an SQL server because for some reason they will eat up each others resources (even though the SQL server isn't touching 1% of the current system's CPU or RAM). My question is really, are they trying to rip my employers off? Could MS Exchange be installed on their other server (on a virtual instance or not), or does the old one even need replacing at all? Going with their current suggestion will cost the company in excess of £6k, and it seems entirely unnecessary. I apologies, because I know this is probably a little thin on details, but if I carry on I could end up writing a massive essay that no-one will want to read. I've been doing my research, but I'm not knowledgeable enough make any hard decisions. Let me know if you need any more details. Thank you for any help you can offer. Further Details: The new exchange would need to support Outlook Web App, 25 users, a few public mailboxes, and email exchange with Blackberries.

    Read the article

  • Exchange IMAP4 connector - Error Event ID 2006

    - by MikeB
    A couple of users in my organisation use IMAP4 to connect to Exchange 2007 (Update rollup 9 applied) because they prefer Thunderbird / Postbox clients. One of the users is generating errors in the Application Log as follows: An exception Microsoft.Exchange.Data.Storage.ConversionFailedException occurred while converting message Imap4Message 1523, user "*******", folder *********, subject: "******", date: "*******" into MIME format. Microsoft.Exchange.Data.Storage.ConversionFailedException: Message content has become corrupted. ---> System.ArgumentException: Value should be a valid content type in the form 'token/token' Parameter name: value at Microsoft.Exchange.Data.Mime.ContentTypeHeader.set_Value(String value) at Microsoft.Exchange.Data.Storage.MimeStreamWriter.WriteHeader(HeaderId type, String data) at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimeStreamAttachment(StreamAttachmentBase attachment, MimeFlags flags) --- End of inner exception stack trace --- at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimeStreamAttachment(StreamAttachmentBase attachment, MimeFlags flags) at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimeAttachment(MimePartInfo part, MimeFlags flags) at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimePart(MimePartInfo part, MimeFlags mimeFlags) at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimeParts(List`1 parts, MimeFlags mimeFlags) at Microsoft.Exchange.Data.Storage.ItemToMimeConverter.WriteMimePart(MimePartInfo part, MimeFlags mimeFlags) at Microsoft.Exchange.Data.Storage.ImapItemConverter.<>c__DisplayClass2.<WriteMimePart>b__0() at Microsoft.Exchange.Data.Storage.ConvertUtils.CallCts(Trace tracer, String methodName, String exceptionString, CtsCall ctsCall) at Microsoft.Exchange.Data.Storage.ImapItemConverter.WriteMimePart(ItemToMimeConverter converter, MimeStreamWriter writer, OutboundConversionOptions options, MimePartInfo partInfo, MimeFlags conversionFlags) at Microsoft.Exchange.Data.Storage.ImapItemConverter.GetBody(Stream outStream) at Microsoft.Exchange.Data.Storage.ImapItemConverter.GetBody(Stream outStream, UInt32[] indices) From my reading around it seems that the suggestion is to ask users to log in to Outlook / OWA and view the messages there. However, having logged in as the users myself, the messages cannot be found either through searching or by browsing the folder detailed in the log entry. The server returns the following error to the client: "The message could not be retrieved using the IMAP4 protocol. The message has not been deleted and may be accessible using either Microsoft Outlook or Microsoft Office Outlook Web Access. You can also try contacting the original sender of the message to find out about the contents of the message. Retrieval of this message will be retried when the server is updated with a fix that addresses the problem." Messages were transferred in to Exchange by copying them from the old Apple Xserve, accessed using IMAP. So my question, finally: 1. Is there any way to get the IMAP Exchange connector to rebuild its cache of messages since it doesn't seem to be pulling them directly from the MAPI store? 2. Alternatively, if there is no database, any ideas on why these messages don't appear in Outlook or OWA would be gratefully received. Many thanks, Mike

    Read the article

  • Issue using a "used" SSD as a Windows 8.1 Boot Drive

    - by EpiGrad
    So, I'm something of a Mac person, but decided to take a stab at this whole "build yourself a PC" thing - right now, the thing is assembled, posts just fine, and can get to the BIOS. The problem is the drive I want to use - I intended to use a 80 GB Corsair SSD I've had sitting around as the boot drive, and a new Samsung SSD for games and the like. So I boot using a Windows 8.1 install USB stick, and if the Samsung drive is plugged in, it happily offers to install Windows on it. The Corsair drive though, it's flipped out - I reformatted it as a blank NTFS drive (it was HFS for Mac purposes) and the BIOS can't see it, nor can the Windows installer. What's wrong, and how do I fix it? The tools at my disposal are: The current ASUS BIOS that came with my motherboard (a Z87I-Deluxe), a Mac running the latest OS X which can also boot to Windows 7 if needed via either Parallels or Bootcamp. Update 1: Update: Based on a friend's suggestion to switch SATA ports, Windows 8.1's installer can now see the drive as Drive 0, Partition 1, a 83.8 GB "Primary" partition. But when I click it and hit "Next", I get the following error: "We couldn't create a new partition or locate an existing one. For more information, see the Setup log files" - not that it gives any clue how to access those. Update 2: Following a trail of Google suggestions, I ended up going into advanced tools and just reformatting the drive as follows: Start DISKPART. Type LIST DISK and identify your SSD disk number (from 0 to n disks). Type SELECT DISK <n> where <n> is your SSD disk number. Type CLEAN Type CREATE PARTITION PRIMARY Type ACTIVE Type FORMAT FS=NTFS QUICK Type ASSIGN Type EXIT twice (one to get out of DiskPart, the other to exit the command line tool) Per these instructions. This goes well enough, but now I can select the disk for installation, and I get a new error: "Windows 8 cannot be installed to this disk. The selected disk has an MBR partition table. On EFI systems, Windows can only be installed to GP disks." So, Googling that, I do the following: select disk 0 clean convert gpt exit ...and we might have fixed it. Windows is at least trying to install now.

    Read the article

  • Nginx Rewrite Rule For File Within Folder Not Working

    - by user3620111
    Good evening everyone or possible early morning if you are in my neck of the woods. My problem seems trivial but after several hours of testing, researching and fiddling I can't seem to get this simple nginx rewrite function to work. There are several rewrites we need, some will have multiple parameters but I cant even get this simple 1 parameter current url to alter at all to the desired. Current: website.com/public/viewpost.php?id=post-title Desired: website.com/public/post/post-title Can someone kindly point me to as what I have done wrong, I am baffled / very tired... For testing purposes before we launch we were just using a simple port on the server. Here is that section. # Listen on port 7774 for dev test server { listen 7774; server_name localhost; root /usr/share/nginx/html/paa; index index.php home.php index.html index.htm /public/index.php; location ~* /uploads/.*\.php$ { if ($request_uri ~* (^\/|\.jpg|\.png|\.gif)$ ) { break; } return 444; } location ~ \.php$ { try_files $uri @rewrite =404; fastcgi_index index.php; include fastcgi_params; fastcgi_pass php5-fpm-sock; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_intercept_errors on; proxy_set_header Host $host; proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; } location @rewrite { rewrite ^/viewpost.php$ /post/$arg_id? permanent; } } I have tried countless attempts such as above @rewrite and simpler: location / { rewrite ^/post/(.*)$ /viewpost.php?id=$1 last; } location ~ \.php$ { try_files $uri =404; fastcgi_index index.php; include fastcgi_params; fastcgi_pass php5-fpm-sock; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_intercept_errors on; proxy_set_header Host $host; proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; } I can not seem to get anything to work at all, I have tried changing the location tried multiple rules... Please tell me what I have done wrong. Pause for facepalm [relocated from stack overflow as per mod suggestion]

    Read the article

  • Recovering damaged external hard disk by installing internally

    - by nfarshchi
    I had a 1TB Western Digital (My book series) 3.5" USB3. One day, the SATA to USB3 converter board was damaged and has not worked since. I decided to open the cover and use the HDD as an internal HDD. When I attached the HDD to my PC and booted up in Windows, it asked me which type of ????? I want to use "MBR or GBR" (I dont remember the exact question) I chose MBR and Windows gave me a 1TB empty Hard drive. I tried to recover with recover my files and some other recovery programs but no success. Some one told me that you should choosed GBR instead of MBR . How can I do that now? Another guy told me that the SATA to USB3 converter board is coded to save data on HDD and you can not use them internally without losing data, and I should find another SATA to USB3 board (exact same). It is impossible to find because they are not produced any more. Please help me to find a solution to bring back my data. UPDATE I have 1TB WD "Mybook" USB 3. the board that convert sata to usb3 was damaged. so when the HDD was in the box computer did not recognize it. I opened the box and remove HDD to use it internal. after connecting to my PC windows showed me one massage that I had two choice MBR or GPT I choosed MBR one and windows gave me 1TB empty new volume. I tried many recovery software to recover my data but no success. I brought it to one expert recovery company and they told me the converter board (SATA to USB3) make some encryption on data and with out that board you cannot recover any thing. so I bought another empty WD box and put the HDD inside but even after that also there is no file. I tried to recover again in this state but no success. so I have some unanswered question. does this converted boards make any password or encryption? if yes how can I solve it? does using many recovery programs affected my data? any suggestion or solution for bring back my data? I had use recovery programs such as : recover my files , EaseUS data recovery, easy recovery, test disk, Ontrack easy recovery . Note: when I was using test disk it asked me to choose which partition table I want to use. as it was I choose NTFS, does this made any change on data?

    Read the article

  • Nginx config - serving index.html not working

    - by Bill
    I can't figure out how to redirect / to index.html. I've gone through the threads on serverfault and I think I've tried every suggestion including: rewrite statements within location / index index.html at the server level, within location / and within static content moving node.js proxy statements to location ~ /i instead of within location / Obviously something is wrong somewhere else in my configuration. Here is my nginx.conf: worker_processes 1; pid /home/logs/nginx.pid; events { worker_connections 1024; } http { include mime.types; default_type application/octet-stream; sendfile on; keepalive_timeout 65; error_log /home/logs/error.log; access_log /home/logs/access.log combined; include sites-enabled/*; } and my server config located in sites-enabled server { root /home/www/public; listen 80; server_name localhost; # proxy request to node location / { index index.html index.htm; proxy_set_header Host $http_host; proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header X-NginX-Proxy true; proxy_pass http://127.0.0.1:3010; proxy_redirect off; break; } # static content location ~ \.(?:ico|jpe?g|jpeg|gif|css|png|js|swf|xml|woff|eot|svg|ttf|html)$ { access_log off; add_header Pragma public; add_header Cache-Control public; expires 30d; } gzip on; gzip_vary on; gzip_http_version 1.0; gzip_comp_level 2; gzip_proxied any; gzip_min_length 1000; gzip_disable "msie6"; gzip_types text/plain text/css application/json application/x-javascript text/xml application/xml application/xml+rss text/javascript; } Everything else is working just fine. Requests get proxied to node correctly and static content is served correctly. I just need to be able to forward requests made to / to /index.html.

    Read the article

  • Wifi network stopped being visible (and usable) (Linksys wag320n)

    - by s427
    Basically, my wifi network simply stopped working for no apparent reason. It doesn't appear in the list of the available networks anymore. I can see all my neighbors' networks, but not mine. It's as if it doesn't exist anymore. The internet connection (non-wifi), which goes through the same modem/router, is fine though. I already had a similar problem about one year ago (see here: Wifi network SSID not visible ), just after buying this very modem. I finally got it to work after performing two factory resets and getting rid of the Cisco "Magic" software; but this time it's not working. I use a linksys router-modem (WAG320N) which is directly connected (via network cable) to my desktop computer (Windows 7). I have (mainly) two devices that use the wifi network: my phone (Samsung Galaxy Nexus) and an Asus tablet (TF201, aka Transformer Prime). I also resurrected an old laptop computer (Dell, running Windows XP) to test that, and it doesn't see anything either (apart from the 20 other wifi networks, of course ^^). This wifi network was working just fine and has been for about a year. I haven't touched the modem settings so I have no idea what's causing the problem. I tried: making my phone "forget" about my network, hoping it would see it again after that: no luck. re-entering the network informations (SSID/password) manually on my phone: still no luck (says it's not in range) exporting the modem configuration, resetting the modem (factory reset, via modem admin), restarting it, importing the configuration: nope. factory reset, turning it off for 15 minutes, restarting, re-factory reset, and entering the configuration manually: still nothing. Has anybody experienced something similar before? Have you any suggestion to fix that? Thanks in advance. PS: to clear things up, here are the settings of my modem regarding wifi: Basic wireless settings: Configuration: manual Radio Band: 2.4GHz Wireless Network Mode: B/G/N-Mixed SSID: s427 Channel Bandwidth: Wide - 40 MHz Channel Wide Channel: 9 - 2.452GHz Standard Channel: 11 - 2.462GHz SSID Broadcast: Enable Advanced Wireless Settings AP Isolation: Disable Authentication Type: Auto Basic Rate: Default Transmission Rate: Auto N Transmission Rate: Auto CTS Protection Mode: Disable Beacon Interval: 100 DTIM Interval: 1 Fragmentation Threshold: 2346 RTS Threshold: 2346

    Read the article

  • How to Troubleshoot TFS Build Server Failure?

    - by Tarun Arora
    Ever found your self in this helpless situation where you think you have tried every possible suggestion on the internet to bring the build server back but it just won’t work. Well some times before hunting around for a solution it is important to understand what the problem is, if the error messages in the build logs don’t seem to help you can always enable tracing on the build server to get more information on what could possibly be the root cause of failure. In this blog post today I’ll be showing you how to enable tracing on, - TFS 2010/11 Server - Build Server - Client Enable Tracing on Team Foundation Server 2010/2011 On the Team Foundation Server navigate to C:\Program Files\Microsoft Team Foundation Server 2010\Application Tier\Web Services, right click web.config and from the context menu select edit.          Search for the <appSettings> node in the config file and set the value of the key ‘traceWriter’ to true.          In the <System.diagnostics> tag set the value of switches from 0 to 4 to set the trace level to maximum to write diagnostics level trace information.          Restart the TFS Application pool to force this change to take effect. The application pool restart will impact any one using the TFS server at present. Note - It is recommended that you do not make any changes to the TFS production application server, this can have serious consequences and can even jeopardize the installation of your server.          Download the Debug view tool from http://technet.microsoft.com/en-us/sysinternals/bb896647.aspx and set it to capture “Global Events”. Perform any actions in the Team Explorer on the client machine, you should be able to see a series of trace data in the debug view tool now.         Enable Tracing on Build Controller/Agents Log on to the Build Controller/Agent and Navigate to the directory C:\Program Files\Microsoft Team Foundation Server 2010\Tools         Look for the configuration file ‘TFSBuildServiceHost.exe.config’ if it is not already there create a new text file and rename it to ‘TFSBuildServiceHost.exe.config’         To Enable tracing uncomment the <system.diagnostics> and paste the snippet below if it is not already there. <configuration> <system.diagnostics> <switches> <add name="BuildServiceTraceLevel" value="4"/> </switches> <trace autoflush="true" indentsize="4"> <listeners> <add name="myListener" type="Microsoft.TeamFoundation.TeamFoundationTextWriterTraceListener, Microsoft.TeamFoundation.Common, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" initializeData="c:\logs\TFSBuildServiceHost.exe.log" /> <remove name="Default" /> </listeners> </trace> </system.diagnostics> </configuration> The highlighted path above is where the Log file will be created. If the folder is not already there then create the folder, also, make sure that the account running the build service has access to write to this folder.         Restart the build Controller/Agent service from the administration console (or net stop tfsbuildservicehost & net start tfsbuildservicehost) in order for the new setting to be picked up.         Enable TFS Tracing on the Client Machine On the client machine, shut down Visual Studio, navigate to C:\Program Files\Microsoft Visual Studio 10.0\Common 7\IDE          Search for devenv.exe.config, make a backup copy of the config file and right click the file and from the context menu select edit. If its not already there create this file.          Edit devenv.exe.config by adding the below code snippet before the last </configuration> tag <system.diagnostics> <switches> <add name="TeamFoundationSoapProxy" value="4" /> <add name="VersionControl" value="4" /> </switches> <trace autoflush="true" indentsize="3"> <listeners> <add name="myListener" type="Microsoft.TeamFoundation.TeamFoundationTextWriterTraceListener,Microsoft.TeamFoundation.Common, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" initializeData="c:\tf.log" /> <add name="perfListener" type="Microsoft.TeamFoundation.Client.PerfTraceListener, Microsoft.TeamFoundation.Client, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a"/> </listeners> </trace> </system.diagnostics> The highlighted path above is where the Log file will be created. If the folder is not already there then create the folder. Start Visual Studio and after a bit of activity you should be able to see the new log file being created on the folder specified in the config file. Other Resources Below are some Key resource you might like to review. I would highly recommend the documentation, walkthroughs and videos available on MSDN.   Thank you for taking the time out and reading this blog post. If you enjoyed the post, remember to subscribe to http://feeds.feedburner.com/TarunArora. Have you come across an interesting one to one with the build server, please share your experience here. Questions/Feedback/Suggestions, etc please leave a comment. Thank You! Share this post : CodeProject

    Read the article

  • System locking up with suspicious messages about hard disk

    - by Chris Conway
    My system has started behaving strangely, intermittently locking up. I see messages like the following in syslog: Nov 18 22:22:00 claypool kernel: [ 3428.078156] ata3.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x0 Nov 18 22:22:00 claypool kernel: [ 3428.078163] ata3.00: irq_stat 0x40000000 Nov 18 22:22:00 claypool kernel: [ 3428.078167] sr 2:0:0:0: CDB: Test Unit Ready: 00 00 00 00 00 00 Nov 18 22:22:00 claypool kernel: [ 3428.078182] ata3.00: cmd a0/00:00:00:00:00/00:00:00:00:00/a0 tag 0 Nov 18 22:22:00 claypool kernel: [ 3428.078184] res 50/00:03:00:00:00/00:00:00:00:00/a0 Emask 0x1 (device error) Nov 18 22:22:00 claypool kernel: [ 3428.078188] ata3.00: status: { DRDY } Nov 18 22:22:00 claypool kernel: [ 3428.080887] ata3.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x0 Nov 18 22:22:00 claypool kernel: [ 3428.080890] ata3.00: irq_stat 0x40000000 Nov 18 22:22:00 claypool kernel: [ 3428.080893] sr 2:0:0:0: CDB: Test Unit Ready: 00 00 00 00 00 00 Nov 18 22:22:00 claypool kernel: [ 3428.080905] ata3.00: cmd a0/00:00:00:00:00/00:00:00:00:00/a0 tag 0 Nov 18 22:22:00 claypool kernel: [ 3428.080906] res 50/00:03:00:00:00/00:00:00:00:00/a0 Emask 0x1 (device error) Nov 18 22:22:00 claypool kernel: [ 3428.080910] ata3.00: status: { DRDY } And then this: Nov 18 23:13:56 claypool kernel: [ 6544.000798] ata1.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen Nov 18 23:13:56 claypool kernel: [ 6544.000804] ata1.00: failed command: FLUSH CACHE EXT Nov 18 23:13:56 claypool kernel: [ 6544.000814] ata1.00: cmd ea/00:00:00:00:00/00:00:00:00:00/a0 tag 0 Nov 18 23:13:56 claypool kernel: [ 6544.000815] res 40/00:00:00:4f:c2/00:00:00:00:00/40 Emask 0x4 (timeout) Nov 18 23:13:56 claypool kernel: [ 6544.000819] ata1.00: status: { DRDY } Nov 18 23:13:56 claypool kernel: [ 6544.000825] ata1: hard resetting link Nov 18 23:14:01 claypool kernel: [ 6549.360324] ata1: link is slow to respond, please be patient (ready=0) Nov 18 23:14:06 claypool kernel: [ 6554.008091] ata1: COMRESET failed (errno=-16) Nov 18 23:14:06 claypool kernel: [ 6554.008103] ata1: hard resetting link Nov 18 23:14:11 claypool kernel: [ 6559.372246] ata1: link is slow to respond, please be patient (ready=0) Nov 18 23:14:16 claypool kernel: [ 6564.020228] ata1: COMRESET failed (errno=-16) Nov 18 23:14:16 claypool kernel: [ 6564.020235] ata1: hard resetting link Nov 18 23:14:21 claypool kernel: [ 6569.380109] ata1: link is slow to respond, please be patient (ready=0) Nov 18 23:14:31 claypool kernel: [ 6579.460243] ata1: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Nov 18 23:14:31 claypool kernel: [ 6579.486595] ata1.00: configured for UDMA/133 Nov 18 23:14:31 claypool kernel: [ 6579.486601] ata1.00: retrying FLUSH 0xea Emask 0x4 Nov 18 23:14:31 claypool kernel: [ 6579.486939] ata1.00: device reported invalid CHS sector 0 Nov 18 23:14:31 claypool kernel: [ 6579.486952] ata1: EH complete Nov 18 23:17:01 claypool CRON[3910]: (root) CMD ( cd / && run-parts --report /etc/cron.hourly) Nov 18 23:17:01 claypool CRON[3908]: (CRON) error (grandchild #3910 failed with exit status 1) Nov 18 23:17:01 claypool postfix/sendmail[3925]: fatal: open /etc/postfix/main.cf: No such file or directory Nov 18 23:17:01 claypool CRON[3908]: (root) MAIL (mailed 1 byte of output; but got status 0x004b, #012) Nov 18 23:39:01 claypool CRON[4200]: (root) CMD ( [ -x /usr/lib/php5/maxlifetime ] && [ -d /var/lib/php5 ] && find /var/lib/php5/ -type f -cmin +$(/usr/lib/php5/maxlifetime) -print0 | xargs -n 200 -r -0 rm) There are no messages marked after 23:39. When I next tried to use the machine, it would not return from the screensaver (blank screen), nor switch to another terminal, and I had to hard reboot it. [UPDATE] The output of smartctl is here. I had trouble getting this, because / is being mounted read-only (?!), which prevents most applications from running. Also, it may not be related, but I have the following worrying messages in dmesg: [ 10.084596] k8temp 0000:00:18.3: Temperature readouts might be wrong - check erratum #141 [ 10.098477] i2c i2c-0: nForce2 SMBus adapter at 0x600 [ 10.098483] ACPI: resource nForce2_smbus [io 0x0700-0x073f] conflicts with ACPI region SM00 [??? 0x00000700-0x0000073f flags 0x30] [ 10.098486] ACPI: This conflict may cause random problems and system instability [ 10.098487] ACPI: If an ACPI driver is available for this device, you should use it instead of the native driver [ 10.098509] i2c i2c-1: nForce2 SMBus adapter at 0x700 [ 10.112570] Linux agpgart interface v0.103 [ 10.155329] atk: Resources not safely usable due to acpi_enforce_resources kernel parameter [ 10.161506] it87: Found IT8712F chip at 0x290, revision 8 [ 10.161517] it87: VID is disabled (pins used for GPIO) [ 10.161527] it87: in3 is VCC (+5V) [ 10.161528] it87: in7 is VCCH (+5V Stand-By) [ 10.161560] ACPI: resource it87 [io 0x0295-0x0296] conflicts with ACPI region ECRE [??? 0x00000290-0x000002af flags 0x45] [ 10.161562] ACPI: This conflict may cause random problems and system instability [ 10.161564] ACPI: If an ACPI driver is available for this device, you should use it instead of the native driver [UPDATE 2] I swapped in a new SATA cable, per Phil's suggestion. The current output of smartctl is here, if it helps. [UPDATE 3] I don't think the cable fixed it. The system hasn't locked up yet, but my media player crashed a few minutes ago and I have the following in the syslog: Nov 20 16:07:17 claypool kernel: [ 2294.400033] ata1: link is slow to respond, please be patient (ready=0) Nov 20 16:07:47 claypool kernel: [ 2324.084581] ata1: COMRESET failed (errno=-16) Nov 20 16:07:47 claypool kernel: [ 2324.084588] ata1: limiting SATA link speed to 1.5 Gbps Nov 20 16:07:47 claypool kernel: [ 2324.084592] ata1: hard resetting link I get the following response from smartctl: $ sudo smartctl -a /dev/sda [sudo] password for chris: sudo: Can't open /var/lib/sudo/chris/0: Read-only file system smartctl 5.40 2010-03-16 r3077 [i686-pc-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Device: /0:0:0:0 Version: scsiModePageOffset: response length too short, resp_len=47 offset=50 bd_len=46 >> Terminate command early due to bad response to IEC mode page A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options.

    Read the article

  • SQL SERVER – Example of Performance Tuning for Advanced Users with DB Optimizer

    - by Pinal Dave
    Performance tuning is such a subject that everyone wants to master it. In beginning everybody is at a novice level and spend lots of time learning how to master the art of performance tuning. However, as we progress further the tuning of the system keeps on getting very difficult. I have understood in my early career there should be no need of ego in the technology field. There are always better solutions and better ideas out there and we should not resist them. Instead of resisting the change and new wave I personally adopt it. Here is a similar example, as I personally progress to the master level of performance tuning, I face that it is getting harder to come up with optimal solutions. In such scenarios I rely on various tools to teach me how I can do things better. Once I learn about tools, I am often able to come up with better solutions when I face the similar situation next time. A few days ago I had received a query where the user wanted to tune it further to get the maximum out of the performance. I have re-written the similar query with the help of AdventureWorks sample database. SELECT * FROM HumanResources.Employee e INNER JOIN HumanResources.EmployeeDepartmentHistory edh ON e.BusinessEntityID = edh.BusinessEntityID INNER JOIN HumanResources.Shift s ON edh.ShiftID = s.ShiftID; User had similar query to above query was used in very critical report and wanted to get best out of the query. When I looked at the query – here were my initial thoughts Use only column in the select statements as much as you want in the application Let us look at the query pattern and data workload and find out the optimal index for it Before I give further solutions I was told by the user that they need all the columns from all the tables and creating index was not allowed in their system. He can only re-write queries or use hints to further tune this query. Now I was in the constraint box – I believe * was not a great idea but if they wanted all the columns, I believe we can’t do much besides using *. Additionally, if I cannot create a further index, I must come up with some creative way to write this query. I personally do not like to use hints in my application but there are cases when hints work out magically and gives optimal solutions. Finally, I decided to use Embarcadero’s DB Optimizer. It is a fantastic tool and very helpful when it is about performance tuning. I have previously explained how it works over here. First open DBOptimizer and open Tuning Job from File >> New >> Tuning Job. Once you open DBOptimizer Tuning Job follow the various steps indicates in the following diagram. Essentially we will take our original script and will paste that into Step 1: New SQL Text and right after that we will enable Step 2 for Generating Various cases, Step 3 for Detailed Analysis and Step 4 for Executing each generated case. Finally we will click on Analysis in Step 5 which will generate the report detailed analysis in the result pan. The detailed pan looks like. It generates various cases of T-SQL based on the original query. It applies various hints and available hints to the query and generate various execution plans of the query and displays them in the resultant. You can clearly notice that original query had a cost of 0.0841 and logical reads about 607 pages. Whereas various options which are just following it has different execution cost as well logical read. There are few cases where we have higher logical read and there are few cases where as we have very low logical read. If we pay attention the very next row to original query have Merge_Join_Query in description and have lowest execution cost value of 0.044 and have lowest Logical Reads of 29. This row contains the query which is the most optimal re-write of the original query. Let us double click over it. Here is the query: SELECT * FROM HumanResources.Employee e INNER JOIN HumanResources.EmployeeDepartmentHistory edh ON e.BusinessEntityID = edh.BusinessEntityID INNER JOIN HumanResources.Shift s ON edh.ShiftID = s.ShiftID OPTION (MERGE JOIN) If you notice above query have additional hint of Merge Join. With the help of this Merge Join query hint this query is now performing much better than before. The entire process takes less than 60 seconds. Please note that it the join hint Merge Join was optimal for this query but it is not necessary that the same hint will be helpful in all the queries. Additionally, if the workload or data pattern changes the query hint of merge join may be no more optimal join. In that case, we will have to redo the entire exercise once again. This is the reason I do not like to use hints in my queries and I discourage all of my users to use the same. However, if you look at this example, this is a great case where hints are optimizing the performance of the query. It is humanly not possible to test out various query hints and index options with the query to figure out which is the most optimal solution. Sometimes, we need to depend on the efficiency tools like DB Optimizer to guide us the way and select the best option from the suggestion provided. Let me know what you think of this article as well your experience with DB Optimizer. Please leave a comment. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Joins, SQL Optimization, SQL Performance, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • What Did You Do? is a Bad Question

    - by Ajarn Mark Caldwell
    Brian Moran (blog | Twitter) did a great presentation today for the PASS Professional Development Virtual Chapter on The Art of Questions.  One of the points that Brian made was that there are good questions and bad (or at least not-as-good) questions.  Good questions tend to open-up the conversation and engender positive reactions (perhaps even trust and respect) between the participants; and bad questions tend to close-down a conversation either through the narrow list of possible responses (e.g. strictly Yes/No) or through the negative reactions they can produce.  And this explains why I so frequently had problems troubleshooting real-time problems with users in the past.  I’ll explain that in more detail below, but before we go on, let me recommend that you watch the recording of Brian’s presentation to learn why the question Why is often problematic in the U.S. and yet we so often resort to it. For a short portion (3 years) of my career, I taught basic computer skills and Office applications in an adult vocational school, and this gave me ample opportunity to do live troubleshooting of user challenges with computers.  And like many people who ended up in computer related jobs, I also have had numerous times where I was called upon by less computer-savvy individuals to help them with some challenge they were having, whether it was part of my job or not.  One of the things that I noticed, especially during my time as a teacher, was that when I was helping somebody, typically the first question I would ask them was, “What did you do?”  This seemed to me like a good way to start my detective work trying to figure out what happened, what went wrong, how to fix it, and how to help the person avoid it again in the future.  I always asked it in a polite tone of voice as I was just trying to gather the facts before diving in deeper.  However; 99.999% of the time, I always got the same answer, “Nothing!”  For a long time this frustrated me because (remember I’m in detective mode at that point) I knew it could not possibly be true.  They HAD to have done SOMETHING…just tell me what were the last actions you took before this problem presented itself.  But no, they always stuck with “Nothing”.  At which point, with frustration growing, and not a little bit of disdain for their lack of helpfulness, I would usually ask them to move aside while I took over their machine and got them out of whatever they had gotten themselves into.  After a while I just grew used to the fact that this was the answer I would usually receive, but I always kept asking because for the .001% of the people who would actually tell me, I could then help them understand what went wrong and how to avoid it in the future. Now, after hearing Brian’s talk, I understand what the problem was.  Even though I meant to just be in an information gathering mode, the words I was using, “What did YOU do?” have such a strong negative connotation that people would instinctively go into defense-mode and stop sharing information that might make them look bad.  Many of them probably were not even consciously aware that they had gone on the defensive, but the self-preservation instinct, especially self-preservation of the ego, is so strong that people would end up there without even realizing it. So, if “What did you do” is a bad question, what would have been better?  Well, one suggestion that Brian makes in his talk is something along the lines of, “Can you tell me what led up to this?” or “what was happening on the computer right before this came up?”  It’s subtle, but the point is to take the focus off of the person and their behavior; instead depersonalizing it and talk about events from more of a 3rd-party observer point of view.  With this approach, people will be more likely to talk about what the computer did and what they did in response to it without feeling the interrogation spotlight is on them.  They are also more likely to mention other events that occurred around the same time that may or may not be related, but which could certainly help you troubleshoot a larger problem if it is not just user actions.  And that is the ultimate goal of your asking the questions.  So yes, it does matter how you ask the question; and there are such things as good questions and bad questions.  Excellent topic Brian!  Thanks for getting the thinking gears churning! (Cross-posted to the Professional Development Virtual Chapter blog.)

    Read the article

  • International Radio Operators Alphabet in F# &amp; Silverlight &ndash; Part 2

    - by MarkPearl
    So the brunt of my my very complex F# code has been done. Now it’s just putting the Silverlight stuff in. The first thing I did was add a new project to my solution. I gave it a name and VS2010 did the rest of the magic in creating the .Web project etc. In this instance because I want to take the MVVM approach and make use of commanding I have decided to make the frontend a Silverlight4 project. I now need move my F# code into a proper Silverlight Library. Warning – when you create the Silverlight Library VS2010 will ask you whether you want it to be based on Silverlight3 or Silverlight4. I originally went for Silverlight4 only to discover when I tried to compile my solution that I was given an error… Error 12 F# runtime for Silverlight version v4.0 is not installed. Please go to http://go.microsoft.com/fwlink/?LinkId=177463 to download and install matching.. After asking around I discovered that the Silverlight4 F# runtime is not available yet. No problem, the suggestion was to change the F# Silverlight Library to a Silverlight3 project however when going to the properties of the project file – even though I changed it to Silverlight3, VS2010 did not like it and kept reverting it to a Silverlight4 project. After a few minutes of scratching my head I simply deleted Silverlight4 F# Library project and created a new F# Silverlight Library project in Silverlight3 and VS2010 was happy. Now that the project structure is set up, rest is fairly simple. You need to add the Silverlight Library as a reference to the C# Silverlight Front End. Then setup your views, since I was following the MVVM pattern I made a Views & ViewModel folder and set up the relevant View and ViewModels. The MainPageViewModel file looks as follows using System; using System.Net; using System.Windows; using System.Windows.Controls; using System.Windows.Documents; using System.Windows.Ink; using System.Windows.Input; using System.Windows.Media; using System.Windows.Media.Animation; using System.Windows.Shapes; using System.Collections.ObjectModel; namespace IROAFrontEnd.ViewModels { public class MainPageViewModel : ViewModelBase { private string _iroaString; private string _inputCharacters; public string InputCharacters { get { return _inputCharacters; } set { if (_inputCharacters != value) { _inputCharacters = value; OnPropertyChanged("InputCharacters"); } } } public string IROAString { get { return _iroaString; } set { if (_iroaString != value) { _iroaString = value; OnPropertyChanged("IROAString"); } } } public ICommand MySpecialCommand { get { return new MyCommand(this); } } public class MyCommand : ICommand { readonly MainPageViewModel _myViewModel; public MyCommand(MainPageViewModel myViewModel) { _myViewModel = myViewModel; } public event EventHandler CanExecuteChanged; public bool CanExecute(object parameter) { return true; } public void Execute(object parameter) { var result = ModuleMain.ConvertCharsToStrings(_myViewModel.InputCharacters); var newString = ""; foreach (var Item in result) { newString += Item + " "; } _myViewModel.IROAString = newString.Trim(); } } } } One of the features I like in Silverlight4 is the new commanding. You will notice in my I have put the code under the command execute to reference to my F# module. At the moment this could be cleaned up even more, but will suffice for now.. public void Execute(object parameter) { var result = ModuleMain.ConvertCharsToStrings(_myViewModel.InputCharacters); var newString = ""; foreach (var Item in result) { newString += Item + " "; } _myViewModel.IROAString = newString.Trim(); } I then needed to set the view up. If we have a look at the MainPageView.xaml the xaml code will look like the following…. Nothing to fancy, but battleship grey for now… take careful note of the binding of the command in the button to MySpecialCommand which was created in the ViewModel. <UserControl x:Class="IROAFrontEnd.Views.MainPageView" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:d="http://schemas.microsoft.com/expression/blend/2008" xmlns:mc="http://schemas.openxmlformats.org/markup-compatibility/2006" mc:Ignorable="d" d:DesignHeight="300" d:DesignWidth="400"> <Grid x:Name="LayoutRoot" Background="White"> <Grid.RowDefinitions> <RowDefinition/> <RowDefinition/> <RowDefinition/> </Grid.RowDefinitions> <TextBox Grid.Row="0" Text="{Binding InputCharacters, Mode=TwoWay}"/> <Button Grid.Row="1" Command="{Binding MySpecialCommand}"> <TextBlock Text="Generate"/> </Button> <TextBlock Grid.Row="2" Text="{Binding IROAString}"/> </Grid> </UserControl> Finally in the App.xaml.cs file we need to set the View and link it to the ViewModel. private void Application_Startup(object sender, StartupEventArgs e) { var myView = new MainPageView(); var myViewModel = new MainPageViewModel(); myView.DataContext = myViewModel; this.RootVisual = myView; }   Once this is done – hey presto – it worked. I typed in some “Test Input” and clicked the generate button and the correct Radio Operators Alphabet was generated. And that’s the end of my first very basic F# Silverlight application.

    Read the article

  • MySQL server stopped working after upgrade

    - by umpirsky
    I upgraded to 12.04 and my MySQL server just stopped working. It throws: ERROR 2002 (HY000): Can't connect to local MySQL server through socket '/var/run/mysqld/mysqld.sock' (2) I tried to reinstall it from software center, but it fails with: Package operation failed The installation or removal of a software package failed. installArchives() failed: Selecting previously unselected package mysql-server. (Reading database ... (Reading database ... 5% (Reading database ... 10% (Reading database ... 15% (Reading database ... 20% (Reading database ... 25% (Reading database ... 30% (Reading database ... 35% (Reading database ... 40% (Reading database ... 45% (Reading database ... 50% (Reading database ... 55% (Reading database ... 60% (Reading database ... 65% (Reading database ... 70% (Reading database ... 75% (Reading database ... 80% (Reading database ... 85% (Reading database ... 90% (Reading database ... 95% (Reading database ... 100% (Reading database ... 243412 files and directories currently installed.) Unpacking mysql-server (from .../mysql-server_5.5.22-0ubuntu1_all.deb) ... Setting up mysql-server-5.5 (5.5.22-0ubuntu1) ... start: Job failed to start invoke-rc.d: initscript mysql, action "start" failed. dpkg: error processing mysql-server-5.5 (--configure): subprocess installed post-installation script returned error exit status 1 No apport report written because MaxReports is reached already dpkg: dependency problems prevent configuration of mysql-server: mysql-server depends on mysql-server-5.5; however: Package mysql-server-5.5 is not configured yet. dpkg: error processing mysql-server (--configure): dependency problems - leaving unconfigured No apport report written because MaxReports is reached already Errors were encountered while processing: mysql-server-5.5 mysql-server Error in function: Setting up mysql-server-5.5 (5.5.22-0ubuntu1) ... start: Job failed to start invoke-rc.d: initscript mysql, action "start" failed. dpkg: error processing mysql-server-5.5 (--configure): subprocess installed post-installation script returned error exit status 1 dpkg: dependency problems prevent configuration of mysql-server: mysql-server depends on mysql-server-5.5; however: Package mysql-server-5.5 is not configured yet. dpkg: error processing mysql-server (--configure): dependency problems - leaving unconfigured I also tried: $ sudo apt-get install -f Reading package lists... Done Building dependency tree Reading state information... Done The following packages were automatically installed and are no longer required: mysql-server-5.5 mysql-server-core-5.5 Use 'apt-get autoremove' to remove them. 0 upgraded, 0 newly installed, 0 to remove and 0 not upgraded. 1 not fully installed or removed. After this operation, 0 B of additional disk space will be used. Setting up mysql-server-5.5 (5.5.22-0ubuntu1) ... start: Job failed to start invoke-rc.d: initscript mysql, action "start" failed. dpkg: error processing mysql-server-5.5 (--configure): subprocess installed post-installation script returned error exit status 1 Errors were encountered while processing: mysql-server-5.5 E: Sub-process /usr/bin/dpkg returned an error code (1) Any idea? EDIT: Crash report is being auto generated. EDIT: After trying and trying I got suggestion to do: #apt-get --purge remove mysql-server-5.1 mysql-server-5.5 Reading package lists... Done Building dependency tree Reading state information... Done Virtual packages like 'mysql-server-5.1' can't be removed The following packages will be REMOVED: mysql-server-5.5* 0 upgraded, 0 newly installed, 1 to remove and 0 not upgraded. 1 not fully installed or removed. After this operation, 31.3 MB disk space will be freed. Do you want to continue [Y/n]? Y (Reading database ... 243407 files and directories currently installed.) Removing mysql-server-5.5 ... Purging configuration files for mysql-server-5.5 ... Processing triggers for ureadahead ... Processing triggers for man-db ... The most important part is: Virtual packages like 'mysql-server-5.1' can't be removed Any idea?

    Read the article

  • SQL SERVER – SmallDateTime and Precision – A Continuous Confusion

    - by pinaldave
    Some kinds of confusion never go away. Here is one of the ancient confusing things in SQL. The precision of the SmallDateTime is one concept that confuses a lot of people, proven by the many messages I receive everyday relating to this subject. Let me start with the question: What is the precision of the SMALLDATETIME datatypes? What is your answer? Write it down on your notepad. Now if you do not want to continue reading the blog post, head to my previous blog post over here: SQL SERVER – Precision of SMALLDATETIME. A Social Media Question Since the increase of social media conversations, I noticed that the amount of the comments I receive on this blog is a bit staggering. I receive lots of questions on facebook, twitter or Google+. One of the very interesting questions yesterday was asked on Facebook by Raghavendra. I am re-organizing his script and asking all of the questions he has asked me. Let us see if we could help him with his question: CREATE TABLE #temp (name VARCHAR(100),registered smalldatetime) GO DECLARE @test smalldatetime SET @test=GETDATE() INSERT INTO #temp VALUES ('Value1',@test) INSERT INTO #temp VALUES ('Value2',@test) GO SELECT * FROM #temp ORDER BY registered DESC GO DROP TABLE #temp GO Now when the above script is ran, we will get the following result: Well, the expectation of the query was to have the following result. The row which was inserted last was expected to return as first row in result set as the ORDER BY descending. Side note: Because the requirement is to get the latest data, we can’t use any  column other than smalldatetime column in order by. If we use name column in the order by, we will get an incorrect result as it can be any name. My Initial Reaction My initial reaction was as follows: 1) DataType DateTime2: If file precision of the column is expected from the column which store date and time, it should not be smalldatetime. The precision of the column smalldatetime is One Minute (Read Here) for finer precision use DateTime or DateTime2 data type. Here is the code which includes above suggestion: CREATE TABLE #temp (name VARCHAR(100), registered datetime2) GO DECLARE @test datetime2 SET @test=GETDATE() INSERT INTO #temp VALUES ('Value1',@test) INSERT INTO #temp VALUES ('Value2',@test) GO SELECT * FROM #temp ORDER BY registered DESC GO DROP TABLE #temp GO 2) Tie Breaker Identity: There are always possibilities that two rows were inserted at the same time. In that case, you may need a tie breaker. If you have an increasing identity column, you can use that as a tie breaker as well. CREATE TABLE #temp (ID INT IDENTITY(1,1), name VARCHAR(100),registered datetime2) GO DECLARE @test datetime2 SET @test=GETDATE() INSERT INTO #temp VALUES ('Value1',@test) INSERT INTO #temp VALUES ('Value2',@test) GO SELECT * FROM #temp ORDER BY ID DESC GO DROP TABLE #temp GO Those two were the quick suggestions I provided. It is not necessary that you should use both advices. It is possible that one can use only DATETIME datatype or Identity column can have datatype of BIGINT or have another tie breaker. An Alternate NO Solution In the facebook thread this was also discussed as one of the solutions: CREATE TABLE #temp (name VARCHAR(100),registered smalldatetime) GO DECLARE @test smalldatetime SET @test=GETDATE() INSERT INTO #temp VALUES ('Value1',@test) INSERT INTO #temp VALUES ('Value2',@test) GO SELECT name, registered, ROW_NUMBER() OVER(ORDER BY registered DESC) AS "Row Number" FROM #temp ORDER BY 3 DESC GO DROP TABLE #temp GO However, I believe it is not the solution and can be further misleading if used in a production server. Here is the example of why it is not a good solution: CREATE TABLE #temp (name VARCHAR(100) NOT NULL,registered smalldatetime) GO DECLARE @test smalldatetime SET @test=GETDATE() INSERT INTO #temp VALUES ('Value1',@test) INSERT INTO #temp VALUES ('Value2',@test) GO -- Before Index SELECT name, registered, ROW_NUMBER() OVER(ORDER BY registered DESC) AS "Row Number" FROM #temp ORDER BY 3 DESC GO -- Create Index ALTER TABLE #temp ADD CONSTRAINT [PK_#temp] PRIMARY KEY CLUSTERED (name DESC) GO -- After Index SELECT name, registered, ROW_NUMBER() OVER(ORDER BY registered DESC) AS "Row Number" FROM #temp ORDER BY 3 DESC GO DROP TABLE #temp GO Now let us examine the resultset. You will notice that an index which is created on the base table which is (indeed) schema change the table but can affect the resultset. As you can see, an index can change the resultset, so this method is not yet perfect to get the latest inserted resultset. No Schema Change Requirement After giving these two suggestions, I was waiting for the feedback of the asker. However, the requirement of the asker was there can’t be any schema change because the application was used by many other applications. I validated again, and of course, the requirement is no schema change at all. No addition of the column of change of datatypes of any other columns. There is no further help as well. This is indeed an interesting question. I personally can’t think of any solution which I could provide him given the requirement of no schema change. Can you think of any other solution to this? Need of Database Designer This question once again brings up another ancient question:  “Do we need a database designer?” I often come across databases which are facing major performance problems or have redundant data. Normalization is often ignored when a database is built fast under a very tight deadline. Often I come across a database which has table with unnecessary columns and performance problems. While working as Developer Lead in my earlier jobs, I have seen developers adding columns to tables without anybody’s consent and retrieving them as SELECT *.  There is a lot to discuss on this subject in detail, but for now, let’s discuss the question first. Do you have any suggestions for the above question? Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: CodeProject, Developer Training, PostADay, SQL, SQL Authority, SQL DateTime, SQL Query, SQL Server, SQL Tips and Tricks, SQLServer, T SQL, Technology

    Read the article

  • How to Answer a Stupid Interview Question the Right Way

    - by AjarnMark
    Have you ever been asked a stupid question during an interview; one that seemed to have no relation to the job responsibilities at all?  Tech people are often caught off-guard by these apparently irrelevant questions, but there is a way you can turn these to your favor.  Here is one idea. While chatting with a couple of folks between sessions at SQLSaturday 43 last weekend, one of them expressed frustration over a seemingly ridiculous and trivial question that she was asked during an interview, and she believes it cost her the job opportunity.  The question, as I remember it being described was, “What is the largest byte measurement?”.  The candidate made up a guess (“zetabyte”) during the interview, which is actually closer than she may have realized.  According to Wikipedia, there is a measurement known as zettabyte which is 10^21, and the largest one listed there is yottabyte at 10^24. My first reaction to this question was, “That’s just a hiring manager that doesn’t really know what they’re looking for in a candidate.  Furthermore, this tells me that this manager really does not understand how to build a team.”  In most companies, team interaction is more important than uber-knowledge.  I didn’t ask, but this could also be another geek on the team trying to establish their Alpha-Geek stature.  I suppose that there are a few, very few, companies that can build their businesses on hiring only the extreme alpha-geeks, but that certainly does not represent the majority of businesses in America. My friend who was there suggested that the appropriate response to this silly question would be, “And how does this apply to the work I will be doing?” Of course this is an understandable response when you’re frustrated because you know you can handle the technical aspects of the job, and it seems like the interviewer is just being silly.  But it is also a direct challenge, which may not be the best approach in interviewing.  I do have to admit, though, that there are those folks who just won’t respect you until you do challenge them, but again, I don’t think that is the majority. So after some thought, here is my suggestion: “Well, I know that there are petabytes and exabytes and things even larger than that, but I haven’t been keeping up on my list of Greek prefixes that have not yet been used, so I would have to look up the exact answer if you need it.  However, I have worked with databases as large as 30 Terabytes.  How big are the largest databases here at X Corporation?”  Perhaps with a follow-up of, “Typically, what I have seen in companies that have databases of your size, is that the three biggest challenges they face are: A, B, and C.  What would you say are the top 3 concerns that you would like the person you hire to be able to address?…Here is how I have dealt with those concerns in the past (or ‘Here is how I would tackle those issues for you…’).” Wait! What just happened?!  We took a seemingly irrelevant and frustrating question and turned it around into an opportunity to highlight our relevant skills and guide the conversation back in a direction more to our liking and benefit.  In more generic terms, here is what we did: Admit that you don’t know the specific answer off the top of your head, but can get it if it’s truly important to the company. Maybe for some reason it really is important to them. Mention something similar or related that you do know, reassuring them that you do have some knowledge in that subject area. Draw a parallel to your past work experience. Ask follow-up questions about the company’s specific needs and discuss how you can fulfill those. This type of thing requires practice and some forethought.  I didn’t come up with this answer until a day later, which is too late when you’re interviewing.  I still think it is silly for an interviewer to ask something like that, but at least this is one way to spin it to your advantage while you consider whether you really want to work for someone who would ask a thing like that.  Remember, interviewing is a two-way process.  You’re deciding whether you want to work there just as much as they are deciding whether they want you. There is always the possibility that this was a calculated maneuver on the part of the hiring manager just to see how quickly you think on your feet and how you handle stupid questions.  Maybe he knows something about the work environment and he’s trying to gauge whether you’ll actually fit in okay.  And if that’s the case, then the above response still works quite well.

    Read the article

  • ASP.NET Web Forms Extensibility: Control Adapters

    - by Ricardo Peres
    All ASP.NET controls from version 2.0 can be associated with a control adapter. A control adapter is a class that inherits from ControlAdapter and it has the chance to interact with the control(s) it is targeting so as to change some of its properties or alter its output. I talked about control adapters before and they really a cool feature. The ControlAdapter class exposes virtual methods for some well known lifecycle events, OnInit, OnLoad, OnPreRender and OnUnload that closely match their Control counterparts, but are fired before them. Because the control adapter has a reference to its target Control, it can cast it to its concrete class and do something with it before its lifecycle events are actually fired. The adapter is also notified before the control is rendered (BeginRender), after their children are renderes (RenderChildren) and after itself is rendered (Render): this way the adapter can modify the control’s output. Control adapters may be specified for any class inheriting from Control, including abstract classes, web server controls and even pages. You can, for example, specify a control adapter for the WebControl and UserControl classes, but, curiously, not for Control itself. When specifying a control adapter for a page, it must inherit from PageAdapter instead of ControlAdapter. The adapter for a control, if specified, can be found on the protected Adapter property, and for a page, on the PageAdapter property. The first use of control adapters that came to my attention was for changing the output of standard ASP.NET web controls so that they were more based on CSS and less on HTML tables: it was the CSS Friendly Control Adapters project, now available at http://code.google.com/p/aspnetcontroladapters/. They are interesting because you specify them in one location and they apply anywhere a control of the target type is created. Mind you, it applies to controls declared on markup as well as controls created by code with the new operator. So, how do you use control adapters? The most usual way is through a browser definition file. In it, you specify a set of control adapters and their target controls, for a given browser. This browser definition file is a XML file with extension .Browser, and can either be global (%WINDIR%\Microsoft.NET\Framework64\vXXXX\Config\Browsers) or local to the web application, in which case, it must be placed inside the App_Browsers folder at the root of the web site. It looks like this: 1: <browsers> 2: <browser refID="Default"> 3: <controlAdapters> 4: <adapter controlType="System.Web.UI.WebControls.TextBox" adapterType="MyNamespace.TextBoxAdapter, MyAssembly" /> 5: </controlAdapters> 6: </browser> 7: </browsers> A browser definition file targets a specific browser, so you can have different definitions for Chrome, IE, Firefox, Opera, as well as for specific version of each of those (like IE8, Firefox3). Alternatively, if you set the target to Default, it will apply to all. The reason to pick a specific browser and version might be, for example, in order to circumvent some limitation present in that specific version, so that on markup you don’t need to be concerned with that. Another option is through the the current Browser object of the request: 1: this.Context.Request.Browser.Adapters.Add(typeof(TextBox).FullName, typeof(TextBoxAdapter).FullName); This must go very early on the page lifecycle, for example, on the OnPreInit event, or even on Application_Start. You have to specify the full class name for both the target control and the adapter. Of course, you have to do this for every request, because it won’t be persisted. As an example, you may know that the classic TextBox control renders an HTML input tag if its TextMode is set to SingleLine and a textarea if set to MultiLine. Because the textarea has no notion of maximum length, unlike the input, something must be done in order to enforce this. Here’s a simple suggestion: 1: public class TextBoxControlAdapter : ControlAdapter 2: { 3: protected TextBox Target 4: { 5: get 6: { 7: return (this.Control as TextBox); 8: } 9: } 10:  11: protected override void OnLoad(EventArgs e) 12: { 13: if ((this.Target.MaxLength > 0) && (this.Target.TextMode == TextBoxMode.MultiLine)) 14: { 15: if (this.Target.Page.ClientScript.IsClientScriptBlockRegistered("TextBox_KeyUp") == false) 16: { 17: if (this.Target.Page.ClientScript.IsClientScriptBlockRegistered(this.Target.Page.GetType(), "TextBox_KeyUp") == false) 18: { 19: String script = String.Concat("function TextBox_KeyUp(sender) { if (sender.value.length > ", this.Target.MaxLength, ") { sender.value = sender.value.substr(0, ", this.Target.MaxLength, "); } }\n"); 20:  21: this.Target.Page.ClientScript.RegisterClientScriptBlock(this.Target.Page.GetType(), "TextBox_KeyUp", script, true); 22: } 23:  24: this.Target.Attributes["onkeyup"] = "TextBox_KeyUp(this)"; 25: } 26: } 27: 28: base.OnLoad(e); 29: } 30: } What it does is, for every TextBox control, if it is set for multi line and has a defined maximum length, it injects some JavaScript that will filter out any content that exceeds this maximum length. This will occur for any TextBox that you may have on your site, or any class that inherits from it. You can use any of the previous options to register this adapter. Stay tuned for more ASP.NET Web Forms extensibility tips!

    Read the article

  • Better documentation for tasks waiting on resources

    - by SQLOS Team
    The sys.dm_os_waiting_tasks DMV contains a wealth of useful information about tasks waiting on a resource, but until now detailed information about the resource being consumed - sys.dm_os_waiting_tasks.resource_description - hasn't been documented, apart from a rather self-evident "Description of the resource that is being consumed."   Thanks to a recent Connect suggestion this column will get more information added. Here is a summary of the possible values that can appear in this column - Note this information is current for SQL Server 2008 R2 and Denali:   Thread-pool resource owner:•       threadpool id=scheduler<hex-address> Parallel query resource owner:•       exchangeEvent id={Port|Pipe}<hex-address> WaitType=<exchange-wait-type> nodeId=<exchange-node-id> Exchange-wait-type can be one of the following.•       e_waitNone•       e_waitPipeNewRow•       e_waitPipeGetRow•       e_waitSynchronizeConsumerOpen•       e_waitPortOpen•       e_waitPortClose•       e_waitRange Lock resource owner:<type-specific-description> id=lock<lock-hex-address> mode=<mode> associatedObjectId=<associated-obj-id>               <type-specific-description> can be:• For DATABASE: databaselock subresource=<databaselock-subresource> dbid=<db-id>• For FILE: filelock fileid=<file-id> subresource=<filelock-subresource> dbid=<db-id>• For OBJECT: objectlock lockPartition=<lock-partition-id> objid=<obj-id> subresource=<objectlock-subresource> dbid=<db-id>• For PAGE: pagelock fileid=<file-id> pageid=<page-id> dbid=<db-id> subresource=<pagelock-subresource>• For Key: keylock  hobtid=<hobt-id> dbid=<db-id>• For EXTENT: extentlock fileid=<file-id> pageid=<page-id> dbid=<db-id>• For RID: ridlock fileid=<file-id> pageid=<page-id> dbid=<db-id>• For APPLICATION: applicationlock hash=<hash> databasePrincipalId=<role-id> dbid=<db-id>• For METADATA: metadatalock subresource=<metadata-subresource> classid=<metadatalock-description> dbid=<db-id>• For HOBT: hobtlock hobtid=<hobt-id> subresource=<hobt-subresource> dbid=<db-id>• For ALLOCATION_UNIT: allocunitlock hobtid=<hobt-id> subresource=<alloc-unit-subresource> dbid=<db-id> <mode> can be:• Sch-S• Sch-M• S• U• X• IS• IU• IX• SIU• SIX• UIX• BU• RangeS-S• RangeS-U• RangeI-N• RangeI-S• RangeI-U• RangeI-X• RangeX-S• RangeX-U• RangeX-X External resource owner:•       External ExternalResource=<wait-type> Generic resource owner:•       TransactionMutex TransactionInfo Workspace=<workspace-id>•       Mutex•       CLRTaskJoin•       CLRMonitorEvent•       CLRRWLockEvent•       resourceWait Latch resource owner:•       <db-id>:<file-id>:<page-in-file>•       <GUID>•       <latch-class> (<latch-address>)   Further Information Slava Oks's weblog: sys.dm_os_waiting_tasks.Informit.com: Identifying Blocking Using sys.dm_os_waiting_tasks - Ken Henderson   - Guy

    Read the article

  • Using Hadooop (HDInsight) with Microsoft - Two (OK, Three) Options

    - by BuckWoody
    Microsoft has many tools for “Big Data”. In fact, you need many tools – there’s no product called “Big Data Solution” in a shrink-wrapped box – if you find one, you probably shouldn’t buy it. It’s tempting to want a single tool that handles everything in a problem domain, but with large, complex data, that isn’t a reality. You’ll mix and match several systems, open and closed source, to solve a given problem. But there are tools that help with handling data at large, complex scales. Normally the best way to do this is to break up the data into parts, and then put the calculation engines for that chunk of data right on the node where the data is stored. These systems are in a family called “Distributed File and Compute”. Microsoft has a couple of these, including the High Performance Computing edition of Windows Server. Recently we partnered with Hortonworks to bring the Apache Foundation’s release of Hadoop to Windows. And as it turns out, there are actually two (technically three) ways you can use it. (There’s a more detailed set of information here: http://www.microsoft.com/sqlserver/en/us/solutions-technologies/business-intelligence/big-data.aspx, I’ll cover the options at a general level below)  First Option: Windows Azure HDInsight Service  Your first option is that you can simply log on to a Hadoop control node and begin to run Pig or Hive statements against data that you have stored in Windows Azure. There’s nothing to set up (although you can configure things where needed), and you can send the commands, get the output of the job(s), and stop using the service when you are done – and repeat the process later if you wish. (There are also connectors to run jobs from Microsoft Excel, but that’s another post)   This option is useful when you have a periodic burst of work for a Hadoop workload, or the data collection has been happening into Windows Azure storage anyway. That might be from a web application, the logs from a web application, telemetrics (remote sensor input), and other modes of constant collection.   You can read more about this option here:  http://blogs.msdn.com/b/windowsazure/archive/2012/10/24/getting-started-with-windows-azure-hdinsight-service.aspx Second Option: Microsoft HDInsight Server Your second option is to use the Hadoop Distribution for on-premises Windows called Microsoft HDInsight Server. You set up the Name Node(s), Job Tracker(s), and Data Node(s), among other components, and you have control over the entire ecostructure.   This option is useful if you want to  have complete control over the system, leave it running all the time, or you have a huge quantity of data that you have to bulk-load constantly – something that isn’t going to be practical with a network transfer or disk-mailing scheme. You can read more about this option here: http://www.microsoft.com/sqlserver/en/us/solutions-technologies/business-intelligence/big-data.aspx Third Option (unsupported): Installation on Windows Azure Virtual Machines  Although unsupported, you could simply use a Windows Azure Virtual Machine (we support both Windows and Linux servers) and install Hadoop yourself – it’s open-source, so there’s nothing preventing you from doing that.   Aside from being unsupported, there are other issues you’ll run into with this approach – primarily involving performance and the amount of configuration you’ll need to do to access the data nodes properly. But for a single-node installation (where all components run on one system) such as learning, demos, training and the like, this isn’t a bad option. Did I mention that’s unsupported? :) You can learn more about Windows Azure Virtual Machines here: http://www.windowsazure.com/en-us/home/scenarios/virtual-machines/ And more about Hadoop and the installation/configuration (on Linux) here: http://en.wikipedia.org/wiki/Apache_Hadoop And more about the HDInsight installation here: http://www.microsoft.com/web/gallery/install.aspx?appid=HDINSIGHT-PREVIEW Choosing the right option Since you have two or three routes you can go, the best thing to do is evaluate the need you have, and place the workload where it makes the most sense.  My suggestion is to install the HDInsight Server locally on a test system, and play around with it. Read up on the best ways to use Hadoop for a given workload, understand the parts, write a little Pig and Hive, and get your feet wet. Then sign up for a test account on HDInsight Service, and see how that leverages what you know. If you're a true tinkerer, go ahead and try the VM route as well. Oh - there’s another great reference on the Windows Azure HDInsight that just came out, here: http://blogs.msdn.com/b/brunoterkaly/archive/2012/11/16/hadoop-on-azure-introduction.aspx  

    Read the article

  • ResponseStatusLine protocol violation

    - by Tom Hines
    I parse/scrape a few web page every now and then and recently ran across an error that stated: "The server committed a protocol violation. Section=ResponseStatusLine".   After a few web searches, I found a couple of suggestions – one of which said the problem could be fixed by changing the HttpWebRequest ProtocolVersion to 1.0 with the command: 1: HttpWebRequest req = (HttpWebRequest)HttpWebRequest.Create(strURI); 2: req.ProtocolVersion = HttpVersion.Version10;   …but that did not work in my particular case.   What DID work was the next suggestion I found that suggested the use of the setting: “useUnsafeHeaderParsing” either in the app.config file or programmatically. If added to the app.config, it would be: 1: <!-- after the applicationSettings --> 2: <system.net> 3: <settings> 4: <httpWebRequest useUnsafeHeaderParsing ="true"/> 5: </settings> 6: </system.net>   If done programmatically, it would look like this: C++: 1: // UUHP_CPP.h 2: #pragma once 3: using namespace System; 4: using namespace System::Reflection; 5:   6: namespace UUHP_CPP 7: { 8: public ref class CUUHP_CPP 9: { 10: public: 11: static bool UseUnsafeHeaderParsing(String^% strError) 12: { 13: Assembly^ assembly = Assembly::GetAssembly(System::Net::Configuration::SettingsSection::typeid); //__typeof 14: if (nullptr==assembly) 15: { 16: strError = "Could not access Assembly"; 17: return false; 18: } 19:   20: Type^ type = assembly->GetType("System.Net.Configuration.SettingsSectionInternal"); 21: if (nullptr==type) 22: { 23: strError = "Could not access internal settings"; 24: return false; 25: } 26:   27: Object^ obj = type->InvokeMember("Section", 28: BindingFlags::Static | BindingFlags::GetProperty | BindingFlags::NonPublic, 29: nullptr, nullptr, gcnew array<Object^,1>(0)); 30:   31: if(nullptr == obj) 32: { 33: strError = "Could not invoke Section member"; 34: return false; 35: } 36:   37: FieldInfo^ fi = type->GetField("useUnsafeHeaderParsing", BindingFlags::NonPublic | BindingFlags::Instance); 38: if(nullptr == fi) 39: { 40: strError = "Could not access useUnsafeHeaderParsing field"; 41: return false; 42: } 43:   44: if (!(bool)fi->GetValue(obj)) 45: { 46: fi->SetValue(obj, true); 47: } 48:   49: return true; 50: } 51: }; 52: } C# (CSharp): 1: using System; 2: using System.Reflection; 3:   4: namespace UUHP_CS 5: { 6: public class CUUHP_CS 7: { 8: public static bool UseUnsafeHeaderParsing(ref string strError) 9: { 10: Assembly assembly = Assembly.GetAssembly(typeof(System.Net.Configuration.SettingsSection)); 11: if (null == assembly) 12: { 13: strError = "Could not access Assembly"; 14: return false; 15: } 16:   17: Type type = assembly.GetType("System.Net.Configuration.SettingsSectionInternal"); 18: if (null == type) 19: { 20: strError = "Could not access internal settings"; 21: return false; 22: } 23:   24: object obj = type.InvokeMember("Section", 25: BindingFlags.Static | BindingFlags.GetProperty | BindingFlags.NonPublic, 26: null, null, new object[] { }); 27:   28: if (null == obj) 29: { 30: strError = "Could not invoke Section member"; 31: return false; 32: } 33:   34: // If it's not already set, set it. 35: FieldInfo fi = type.GetField("useUnsafeHeaderParsing", BindingFlags.NonPublic | BindingFlags.Instance); 36: if (null == fi) 37: { 38: strError = "Could not access useUnsafeHeaderParsing field"; 39: return false; 40: } 41:   42: if (!Convert.ToBoolean(fi.GetValue(obj))) 43: { 44: fi.SetValue(obj, true); 45: } 46:   47: return true; 48: } 49: } 50: }   F# (FSharp): 1: namespace UUHP_FS 2: open System 3: open System.Reflection 4: module CUUHP_FS = 5: let UseUnsafeHeaderParsing(strError : byref<string>) : bool = 6: // 7: let assembly : Assembly = Assembly.GetAssembly(typeof<System.Net.Configuration.SettingsSection>) 8: if (null = assembly) then 9: strError <- "Could not access Assembly" 10: false 11: else 12: 13: let myType : Type = assembly.GetType("System.Net.Configuration.SettingsSectionInternal") 14: if (null = myType) then 15: strError <- "Could not access internal settings" 16: false 17: else 18: 19: let obj : Object = myType.InvokeMember("Section", BindingFlags.Static ||| BindingFlags.GetProperty ||| BindingFlags.NonPublic, null, null, Array.zeroCreate 0) 20: if (null = obj) then 21: strError <- "Could not invoke Section member" 22: false 23: else 24: 25: // If it's not already set, set it. 26: let fi : FieldInfo = myType.GetField("useUnsafeHeaderParsing", BindingFlags.NonPublic ||| BindingFlags.Instance) 27: if(null = fi) then 28: strError <- "Could not access useUnsafeHeaderParsing field" 29: false 30: else 31: 32: if (not(Convert.ToBoolean(fi.GetValue(obj)))) then 33: fi.SetValue(obj, true) 34: 35: // Now return true 36: true VB (Visual Basic): 1: Option Explicit On 2: Option Strict On 3: Imports System 4: Imports System.Reflection 5:   6: Public Class CUUHP_VB 7: Public Shared Function UseUnsafeHeaderParsing(ByRef strError As String) As Boolean 8:   9: Dim assembly As [Assembly] 10: assembly = [assembly].GetAssembly(GetType(System.Net.Configuration.SettingsSection)) 11:   12: If (assembly Is Nothing) Then 13: strError = "Could not access Assembly" 14: Return False 15: End If 16:   17: Dim type As Type 18: type = [assembly].GetType("System.Net.Configuration.SettingsSectionInternal") 19: If (type Is Nothing) Then 20: strError = "Could not access internal settings" 21: Return False 22: End If 23:   24: Dim obj As Object 25: obj = [type].InvokeMember("Section", _ 26: BindingFlags.Static Or BindingFlags.GetProperty Or BindingFlags.NonPublic, _ 27: Nothing, Nothing, New [Object]() {}) 28:   29: If (obj Is Nothing) Then 30: strError = "Could not invoke Section member" 31: Return False 32: End If 33:   34: ' If it's not already set, set it. 35: Dim fi As FieldInfo 36: fi = [type].GetField("useUnsafeHeaderParsing", BindingFlags.NonPublic Or BindingFlags.Instance) 37: If (fi Is Nothing) Then 38: strError = "Could not access useUnsafeHeaderParsing field" 39: Return False 40: End If 41:   42: If (Not Convert.ToBoolean(fi.GetValue(obj))) Then 43: fi.SetValue(obj, True) 44: End If 45:   46: Return True 47: End Function 48: End Class   Technorati Tags: C++,CPP,VB,Visual Basic,F#,FSharp,C#,CSharp,ResponseStatusLine,protocol violation

    Read the article

  • SQL SERVER – Recover the Accidentally Renamed Table

    - by pinaldave
    I have no answer to following question. I saw a desperate email marked as urgent delivered in my mailbox. “I accidentally renamed table in my SSMS. I was scrolling very fast and I made mistakes. It was either because I double clicked or clicked on F2 (shortcut key for renaming). However, I have made the mistake and now I have no idea how to fix this. I am in big trouble. Help me get my original tablename.” I have seen many similar scenarios in my life and they give me a very good opportunity to preach wisdom but when the house is burning, we cannot talk about how we should have conserved the water earlier. The goal at that point is to put off the fire as fast as we can. I decided to answer this email with my best knowledge. If you have renamed the table, I think you pretty much is out of luck. Here are few things which you can do which can give you idea about what your tablename can be if you are lucky. Method 1: (Not Recommended but try your luck) Check your naming convention of your system. I have often seen that many organizations name their index as IX_TableName_Colms or name their keys as FK_TableName1_TableName2_Cols. If your organization is following the same you can get the name from your table, you may refer your keys. Again, note that this is quite possible that your tablename was already renamed and your keys were not updated. This can easily lead you to select incorrect name. I think follow this if you are confident or move to the next method. Method 2: (Not Recommended but try your luck) This method is also based on your orgs naming convention. If you use the name of the table in any columnname (some organizations use tablename in their incremental identity column name), you can get that name from there. Method 3: (Not Recommended but try your luck) If you know where your table was used in your stored procedures, you can script your stored procedure and find the name of the table back. Method 4: (Try your luck) All the best organizations first create a data model of the schema and there is good chance that this table is used there, you should take your chances and refer original document. If your organization is good at managing docs or source code, you will get the name of the table back for sure. Method 5: (It WORKS but try on a development server) There is no sure way to get you the name of the table which you accidentally renamed however, there is one way which will work for sure. You need to take your latest full backup and restore it on your development server (remember not on production or where you have renamed this column). Now restore latest differential file of the full backup. Now restore all the log files one by one making sure that you are restoring before the point of time of you renamed the tablename. Now go to explore and this will give you the name of the table which you have renamed. If you are confident that the same table existed with the same name when the last full backup was made, you do not have to go to all the steps. You can just get the name of the table directly from last backup’s restore. Read the article about Backup Timeline. Wisdom: How can I miss to preach wisdom when I get the opportunity to do so? Here are a few points to remember. Use a different account to explore production environment. Do not use the same account which have all the rights and permissions all the time. Use the account which has read only permissions if there are no modification required. Use policy based management to prevent changes which are accidental. If there was policy of valid names, the accidental change of the table was not possible unless it was intentional delibarate changes. Have a proper auditing of the system in place. You can use DDL triggers but be careful with its usage (get it reviewed properly first). (Add your suggestion here) I guess Method 5 will work all the time (using point in time restore). Everything else is chance of luck and if you are lucky are bad – you will get further incorrect name. Now go back and read the first line of this blog. Out of five method four methods are just lucky guesses. The method 5 will work but again it is a lengthy process if the size of the database is huge or if you do not have full backup. Did I miss anything obvious? Please leave a comment and I will publish your answer with due credit. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Puzzle, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

< Previous Page | 98 99 100 101 102 103 104 105 106 107 108 109  | Next Page >