Search Results

Search found 59864 results on 2395 pages for 'application security'.

Page 103/2395 | < Previous Page | 99 100 101 102 103 104 105 106 107 108 109 110  | Next Page >

  • Threads slowing down application and not working properly

    - by Belgin
    I'm making a software renderer which does per-polygon rasterization using a floating point digital differential analyzer algorithm. My idea was to create two threads for rasterization and have them work like so: one thread draws each even scanline in a polygon and the other thread draws each odd scanline, and they both start working at the same time, but the main application waits for both of them to finish and then pauses them before continuing with other computations. As this is the first time I'm making a threaded application, I'm not sure if the following method for thread synchronization is correct: First of all, I use two global variables to control the two threads, if a global variable is set to 1, that means the thread can start working, otherwise it must not work. This is checked by the thread running an infinite loop and if it detects that the global variable has changed its value, it does its job and then sets the variable back to 0 again. The main program also uses an empty while to check when both variables become 0 after setting them to 1. Second, each thread is assigned a global structure which contains information about the triangle that is about to be rasterized. The structures are filled in by the main program before setting the global variables to 1. My dilemma is that, while this process works under some conditions, it slows down the program considerably, and also it fails to run properly when compiled for Release in Visual Studio, or when compiled with any sort of -O optimization with gcc (i.e. nothing on screen, even SEGFAULTs). The program isn't much faster by default without threads, which you can see for yourself by commenting out the #define THREADS directive, but if I apply optimizations, it becomes much faster (especially with gcc -Ofast -march=native). N.B. It might not compile with gcc because of fscanf_s calls, but you can replace those with the usual fscanf, if you wish to use gcc. Because there is a lot of code, too much for here or pastebin, I created a git repository where you can view it. My questions are: Why does adding these two threads slow down my application? Why doesn't it work when compiling for Release or with optimizations? Can I speed up the application with threads? If so, how? Thanks in advance.

    Read the article

  • AJAX Web Application Development Explained

    This article talks about the revolutionary Ajax technology that is widely used for Web Application Development and its related advantages. The different applications of Ajax style Web Application Development are also described herein.

    Read the article

  • APress Deal of the Day 12/Oct/2013 - Beginning Windows 8 Application Development – XAML Edition

    - by TATWORTH
    Originally posted on: http://geekswithblogs.net/TATWORTH/archive/2013/10/12/apress-deal-of-the-day-12oct2013---beginning-windows-8.aspxToday's $10 deal of the day from APress at http://www.apress.com/9781430245667 is Beginning Windows 8 Application Development – XAML Edition "Beginning Windows 8 Application Development – XAML Edition shows you how to start building rich, immersive applications that connect people, applications, and devices with Windows 8."

    Read the article

  • Custom Business Application Development in PHP - Features & Benefits

    A revolution is taking place within the business application arena today. Just a few years back most custom business applications such as CRM, ERP, data mining and other business data information systems were inflexible and expensive applications. The database ran on a server within the company's compounds and each desktop machine was running a client application.

    Read the article

  • FIX: A dump file is not generated for a .NET Framework 2.0-based application after the application c

    981878 ... FIX: A dump file is not generated for a .NET Framework 2.0-based application after the application closesThis RSS feed provided by kbAlerz.com.Visit kbAlertz.com to subscribe. It's 100% free and you'll be able to recieve e-mail or RSS updates for the technologies you pick from the Microsoft Knowledge Base....Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • A walkthrough to Application State

    This artcile discuss about the Application Level events,Application state with a simple example...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Oracle Application Testing Suite 12.1 ??????????

    - by user773457
    Oracle Application Testing Suite 12.1 ??????????? http://japanmediacentre.oracle.com/content/detail.aspx?ReleaseID=1692???????????????? ?JD Edwards EnterpriseOne????????????????????????????????????? ?Oracle Application Testing Suite 12.1????????????????????????(IE9?Linux) ??????????????Oracle Enterprise Manager????????Oracle Cloud???????????????? ???????SQL?????????SELECT???????????????????????????? ??????????????????????????????????? ???? ATS-Tech ??????????

    Read the article

  • WMI permissions: Select CommandLine, ProcessId FROM Win32_Process returns no data for CommandLine

    - by user57935
    Hi all, I am gathering performance data via WMI and would like to avoid having to use an account in the Administrators group for this purpose. The target machine is running Windows Server 2003 with the latest SP/updates. I've done what I believe to be the appropriate configuration to allow our user access to WMI (similar to what is described here: http://msdn.microsoft.com/en-us/library/aa393266.aspx). Here are the specific steps that were followed: Open Administrative Tools - Computer Management: Under Computer Management (Local) Expand Services and Applications, right click WMI Control and select properties. In the Security tab, expand Root, highlight CIMV2, click Security (near bottom of window); add Performance Monitor Users and enable the options : Enable Account and Remote Enable. ­Open Administrative Tools - Component Services: Under Console Root go to Component Services- Computers - Right click My Computer and select properties, select the COM security tab, in “Access Permissions” click "Edit Default" select(or add then select) “Performance Monitor Users” group and allow local access and remote access and click ok. In “Launch and Activation Permissions” click “Edit Default” select(or add then select) “Performance Monitor Users” group and allow Local and Remote Launch and Activation Permissions. ­Open Administrative Tools - Component Services: Under Console Root go to Component Services- Computers - My Computer - DCOM Config - highlight “Windows Management and Instrumentation” right click and select properties, Select the Security tab, Under “Launch and Activation Permissions” select Customize, then click edit, add the “Performance Users Group” and allow local and remote Remote Launch and Remote Activation privileges. I am able to connect remotely via WMI Explorer but when I perform this query: Select CommandLine, ProcessId FROM Win32_Process I get a valid result but every row has an empty CommandLine. If I add the user to the Administrators group and re-run the query, the CommandLine column contains the expected data. It seems there is a permission I am missing somewhere but I am not having much luck tracking it down. Many thanks in advance.

    Read the article

  • WMI permissions: Select CommandLine, ProcessId FROM Win32_Process returns no data for CommandLine

    - by user57935
    I am gathering performance data via WMI and would like to avoid having to use an account in the Administrators group for this purpose. The target machine is running Windows Server 2003 with the latest SP/updates. I've done what I believe to be the appropriate configuration to allow our user access to WMI (similar to what is described here: http://msdn.microsoft.com/en-us/library/aa393266.aspx). Here are the specific steps that were followed: Open Administrative Tools - Computer Management: Under Computer Management (Local) Expand Services and Applications, right click WMI Control and select properties. In the Security tab, expand Root, highlight CIMV2, click Security (near bottom of window); add Performance Monitor Users and enable the options : Enable Account and Remote Enable. ­Open Administrative Tools - Component Services: Under Console Root go to Component Services- Computers - Right click My Computer and select properties, select the COM security tab, in “Access Permissions” click "Edit Default" select(or add then select) “Performance Monitor Users” group and allow local access and remote access and click ok. In “Launch and Activation Permissions” click “Edit Default” select(or add then select) “Performance Monitor Users” group and allow Local and Remote Launch and Activation Permissions. ­Open Administrative Tools - Component Services: Under Console Root go to Component Services- Computers - My Computer - DCOM Config - highlight “Windows Management and Instrumentation” right click and select properties, Select the Security tab, Under “Launch and Activation Permissions” select Customize, then click edit, add the “Performance Users Group” and allow local and remote Remote Launch and Remote Activation privileges. I am able to connect remotely via WMI Explorer but when I perform this query: Select CommandLine, ProcessId FROM Win32_Process I get a valid result but every row has an empty CommandLine. If I add the user to the Administrators group and re-run the query, the CommandLine column contains the expected data. It seems there is a permission I am missing somewhere but I am not having much luck tracking it down. Many thanks in advance.

    Read the article

  • signed applet automatically running as insecure

    - by Terje Dahl
    My application is deployed as a self-signed applet to several thousand users at more than 50 schools across the country (in Norway). The user is presented with the standard Java security warning asking if they will accept the signature. When they do, the applet runs perfectly. However, about half a year ago a group of 7 school, all under a common IT department, stopped getting the security warning. In stead the applet loads and starts running in untrusted mode, without first giving the user an option to accept or reject the signature. The problem is on Windows machines, and only when the machine is connected to the schools network. If they take the same machine home with them, the program functions as it should, with security warnings and everything. I know little about Window systems in general, but I would think it would be some sort of policy-file or something that is loaded when a machine hooks up to/through the schools network. Furthermore, the problem only started occurring in these 7 schools after changes made after a security breach they had a while back. The IT department is stumped. I am stumped. Any thoughts, comments, suggestions?

    Read the article

  • Resolving "JBoss Web Console is Accessible to Unauthenticated Remote Users" vulnerability

    - by IAmJeff
    Our security team has determined there is a vulnerability in one of our systems. We are using version JBoss 5.1.0GA on RHEL 5.10. Vulnerability description: JBoss Web Console is Accessible to Unauthenticated Remote Users Yes, this looks familiar. Refer to Question 501417. I do not find the answer there complete. Can someone (or multiple someones) answer Does a newer version of JBoss fix this vulnerability? Are there links describing, in more detail, manual modification of JBoss configuration files to resolve the issue? Are there others options to remediate this vulnerability? Why don't I find the other answer complete? I'm not at all familiar with JBoss, so this answer seems a bit too simple. The web-console.war contains commented-out templates for basic security in its WEB-INF/web.xml as well as commented-out setup for a security domain in WEB-INF/jboss-web.xml. Just uncomment those basic security blocks and restart? Is there anything else I need to include? This seems generic. Do I need to include anything about my environment, such as absolute paths, etc.? Am I making this too complicated?

    Read the article

  • How do I deny access to everybody but me in Windows 7?

    - by GregH
    I am trying to set up a file server on my my Windows 7 Pro system at home. I set up one common "Share" folder that I have shared/published. Within the share folder I want to have individual folders for me and my wife...that is only I can read/write my folder and only my wife can read/write to her folder and neither of us can read the contents of the other person's folder. Then I want to have a "public" folder where we can both read/write to contents of the folder as well as any sub-folders created, but my "kids" account can only read from this folder and sub folders. It seems really confusing to set up something like this and it really shouldn't. I am really confused between the "allow", "deny", and dimmed check boxes in the security tab. It seems that if I "Deny" access to "Everyone" on my private folder, then I don't even have access to it. Windows security seems backwards from the rest of the world's security models. If I am in two groups and I deny access to one of the groups but allow access to the other group then Windows security denies me access as I am in one of the groups that has access disallowed. Very confusing.

    Read the article

  • Can't add service account to domain group during SQL cluster install

    - by Sam
    I'm installing a 2008 instance on a Server 2003 machine which is already running SQL 2005. I need to set up domain groups for the security setup step: http://msdn.microsoft.com/en-us/library/ms179530.aspx On Windows Server 2003, specify domain groups for SQL Server services. All resource permissions are controlled by domain-level groups that include SQL Server service accounts as group members. Much more info on this here: http://support.microsoft.com/kb/910708 I've had problems with being able to add the windows service accounts to the groups at install time. The security admins had to make my account a domain admin - which they were hesitant to do. The account under which SQL Server Setup is running must have permissions to add accounts to the domain groups. Is there a specific security setting which would allow my account to add accounts to a group? UPDATE: I'm looking for specific instructions. I have a global group called domain\servicegroup - what do I tell the security folks to do. I'd love to figure it out myself, but I don't have access to this stuff.

    Read the article

  • Win2k8R2 / IIS 7.5 - users getting 503 response, no 503 error reported in logs

    - by merk
    I've got 2 web servers with mirrored content. There's a load balancer sitting in front of them. Starting yesterday we've been getting people complaining about 503 errors. i can't find any 503 errors in the IIS log file. However the server host is saying these errors are due to .Net errors in our website which are causing the app pool to recycle. They pointed out several errors in the windows application event log which look like this: Log Name: Application Source: ASP.NET 4.0.30319.0 Date: 3/31/2012 8:35:37 PM Event ID: 1309 Task Category: Web Event Level: Warning Keywords: Classic User: N/A Computer: 6251.local Description: Event code: 3005 Event message: An unhandled exception has occurred. Event time: 3/31/2012 8:35:37 PM Event time (UTC): 4/1/2012 1:35:37 AM Event ID: e7a580c7b38545cca3416a8595408f24 Event sequence: 97 Event occurrence: 1 Event detail code: 0 Application information: Application domain: /LM/W3SVC/2/ROOT-1-129777167518960645 Trust level: Full Application Virtual Path: / Application Path: C:\inetpub\wwwroot\mywebsite\ Machine name: 6252 Process information: Process ID: 20000 Process name: w3wp.exe Account name: IIS APPPOOL\MyAppPool In particular they are saying that the account name under Process Information indicates that the app pool is recycling. They said if the app pool were not recycle, the accountname would instead be the folder where the website files are located. I checked the app pool settings - it's set to recycle every 29 hours. And the rapid fail protection is set to the default of 5 failures in 5 minutes. But i have not seen 5 failures in the event log in that short of a time span. Can anyone help me confirm if the 503 responses are indeed being generated by the app pools recycling? Or are these errors coming from somewhere else? My guess at the time was their load balancer was the one actually returning the 503 error. But that was just a guess.

    Read the article

  • What are ways to prevent files with the Right-to-Left Override Unicode character in their name (a malware spoofing method) from being written or read?

    - by galacticninja
    What are ways to avoid or prevent files with the RLO (Right-to-Left Override) Unicode character in their name (a malware method to spoof filenames) from being written or read in a Windows PC? More info on the RLO unicode character here: http://www.fileformat.info/info/unicode/char/202e/index.htm http://en.wikipedia.org/wiki/Bi-directional_text Info on the RLO unicode character when used by malware: http://www.ipa.jp/security/english/virus/press/201110/E_PR201110.html Mirror link: http://webcache.googleusercontent.com/search?q=cache:KasmfOvbVJ8J:www.ipa.jp/security/english/virus/press/201110/E_PR201110.html+&cd=1&hl=en&ct=clnk You can try this RLO character test webpage: http://www.fileformat.info/info/unicode/char/202e/browsertest.htm The RLO character is also already pasted in the 'Input Test' field in that webpage. Try typing there and notice that the characters you're typing are coming out in their reverse orders (right-to-left, instead of left-to-right). In filenames, the RLO character can be specifically positioned in the filename to spoof or masquerade as having a filename or file extension that is different than what it actually has. (Will still be hidden even if 'Hide extensions for known filetypes' is unchecked.) The only info I can find that has info on how to prevent files with the RLO character from being run is from the Information Technology Promotion Agency, Japan website: http://www.ipa.jp/security/english/virus/press/201110/E_PR201110.html (Mirror link). They adviced to use the Local Security Policy settings manager to block files with the RLO character in its name from being run. Can anyone recommend any other good solutions to prevent files with the RLO character in their names from being written or being read in the computer, or a way to alert the user if a file with the RLO character is detected? My OS is Windows 7, but I'll be looking for solutions for Windows XP, Vista and 7, or a solution that will work for all those OSes, to help people using those OSes too.

    Read the article

  • How to (re)enable the "New" context menu items for an administrator when right-clicking in a folder and selecting New > X?

    - by Metro Smurf
    I just migrated from XP x86 to Win7 x64 (clean install). I had a couple of data drives in my XP x86 system that I physically moved to my Win7 x64 system. When browsing a directory in any of the transferred drives, the only option available in the 'new' context menu is "Folder", i.e., Right-Click inside a folder New Folder (this is similar behavior for Win7 when using the context menu in c:\Program Files): However, whenever creating a new folder within any of the directories, all the context menu new items are available within the new folder: Steps I've taken that have failed to add the new context menu items: Removing all security permissions from a directory and sub-directories. Replacing them with new permissions. As well as removing inheritable permissions from the parent. Taking explicit ownership of a directory and sub-directories. Combing the above two. Sample of Effective Permissions that do not work: Steps I've taken that have succeeded to add the new context menu items: Adding the "Everyone" group to the drive and giving the group explicit "Modify" privileges. Giving the "Everyone" group explicit privileges smells wrong. I'm an administrator on my system; why should I have to add the "Everyone" group as well? Adding my username to the drive and giving full permissions. Again, since I'm an administrator on my system and the administrators group already has full control of the drive/directories/folders, why should I have to explicitly add my user name to the security permissions? Finally, The Question: Is it possible to have the New Item context menu have all available options by default without having to explicitly add the everyone group or a specific user name to the security permissions? I'm suspecting that the option may not be available unless the username is explicitly added to the security permissions. Of note: I've seen the registry hacks for updating the new items context menu; my preference is to avoid such hacks and return the functionality to the expected behavior an administrator should have.

    Read the article

  • How to make route-commands execute in the global application scope rather than locally in a page or

    - by Shimmy
    Hello! I created a window that contains a frame, and above the frame it contains a button that its Command property is set to "Refresh". In the page shown in the frame, I set a CommandBinding for Refresh. I want that when the 'Refresh' command is executed it should be caught by the page Refresh_Executed event-handler set in the CommandBinding. In other words, Is there a way to set global Commands that are targeted for the entire application scope and execute everywhere they're bound?

    Read the article

< Previous Page | 99 100 101 102 103 104 105 106 107 108 109 110  | Next Page >