  • Mounting NAS share: Bad Address

    - by Korben
    I've faced to the problem that can't solve. Hope you can help me with it. I have a storage QNAP TS-459U, with it's own Linux, and 'massive1' folder shared, which I need to mount to my Debian server. They are connected by regular patch cord. Debian server has two network interfaces - eth0 and eth1. eth0 is for Internet, eth1 is for QNAP. So, I'm saying this: mount -t cifs //169.254.100.100/massive1/ /mnt/storage -o user=admin , where 169.254.100.100 is an IP of QNAP's interface. The result I get (after entering password): mount error(14): Bad address Refer to the mount.cifs(8) manual page (e.g. man mount.cifs) Tried: mount.cifs, smbmount, with '/' at the end of the network share and without it, and many other variations of that command. And always its: mount error(14): Bad address Funny thing is when I was in Data Center, I had connected my netbook to QNAP by the same scheme (with Fedora 16 on it), and it connected without any problems, I could read/write files on the QNAP's NAS share! So I'm really stuck with the Debian. I can't undrestand where's the difference with Fedora, making this error. Yeah, I've used Google. Couldn't find any useful info. Ping to the QNAP's IP is working, I can log into QNAP's Linux by ssh, telnet on 139's port is working. This is network interface configuration I use in Debian: IP: 169.254.100.1 Netmask: 255.255.0.0 The only diffence in connecting to Fedora and Debian is that in Fedora I've added gateway - 169.254.100.129, but ping to this IP is not working, so I think it's not necessary at all. P.S. ~# cat /etc/debian_version wheezy/sid ~# uname -a Linux host 2.6.32-5-openvz-amd64 #1 SMP Mon Mar 7 22:25:57 UTC 2011 x86_64 GNU/Linux ~# smbtree WORKGROUP \\HOST host server \\HOST\IPC$ IPC Service (host server) \\HOST\print$ Printer Drivers NAS \\MASSIVE1 NAS Server \\MASSIVE1\IPC$ IPC Service (NAS Server) \\MASSIVE1\massive1 \\MASSIVE1\Network Recycle Bin 1 [RAID5 Disk Volume: Drive 1 2 3 4] \\MASSIVE1\Public System default share \\MASSIVE1\Usb System default share \\MASSIVE1\Web System default share \\MASSIVE1\Recordings System default share \\MASSIVE1\Download System default share \\MASSIVE1\Multimedia System default share Please, help me with solving this strange issue. Thanks before.

    Read the article

  • Buffalo TeraStation Firmware Upgrade

    - by jason
    Hi All, I was given a TeraStation HS-DH0.0TGL/R5 It came to me working with 4x250gb. I added 4 x 1TB, TFTP booted and data was copied. How do I load firmware and software now to get it running? I was going based upon this article: http://forums.buffalotech.com/t5/Storage/FAQ-3-of-3-TFTP-boot-procedure-please-read-this/m-p/11015 I downloaded TFTP Boot Recovery HS-DHTGL-R5 2.13.exe and Terastation_112-104.zip Advice is appreciated.

    Read the article

  • How to install ceph on EC2 Amazon Linux AMI

    - by takaomag
    I want to test Ceph (a distributed network storage and file system) on some EC2 hosts which is derived from Amazon Linux AMI (amzn-ami-2011.09.2.x86_64-ebs). The kernel version is 3.2 and btrfs is enabled. But kernel config options related to Ceph (CONFIG_CEPH_FS and CONFIG_BLK_DEV_RBD) seems to be disabled. I have to make a new kernel and register it to amazon ? Or, does someone know more easy way ?

    Read the article

  • Powering-down USB Powered Devices on laptop sleep

    - by Carl
    I recently purchased a Targus Lap Chill Mat, which is a USB powered device, but doesn't have any interface/storage/etc function. I'd like it to power-down when my (macbook) laptop sleeps (since the fan obviously doesn't need to be running when the laptop is idle) without having to unplug it. Any suggestions?

    Read the article

  • mysql server upgrade problem from 5.0 to 5.1

    - by Avinash
    Hi I have upgraded my mysql server from 5.0 to 5.1. But i am having a problem related to tables for InnoDB storage Engine. My default engine is InnoDB, So it is enabled in my server. But tables with InneDB engine are not displaying in phpmyadmin. Tables with MyISAM are displaying properly. and also i can't fire a query on the table with InnoDB Engine. Thanks Avinash

    Read the article

  • Heartbeat (Linux HA) and NetApp?

    - by Drew
    Does anyone have any experience setting up a high availability two node Linux cluster using heartbeat (linux-ha.org) and NetApp storage (preferably using SnapDrive for Linux)? Basically I would like to mount the same NetApp LUN over Fibre Channel to two servers in an Active/Passive mode (only one server can access the LUN at a time) Thanks!

    Read the article

  • New Computer Build Questions

    - by MJ
    I'm in the process of gathering parts and specs for a new machine. I wear many hats, so the machine needs to do a lot. I need at least 2 monitor support, if not three. I also play many online MMOs (wow, aion, war hammer, etc), along with some freelance programming projects. I already have a case which is very large, so it will fit anything. I have 2 other SATA HDs. They are more for storage and basic programs. I feel that the best improvement could be done with a solid state HD, true or not? I'm more of a software/programming guy, so ANY input at all on improving this system build would be appreciated. I have a few questions with this list. AMD or Intel? I don't know enough about either to choose what would best fit me. Thanks! **EDIT: Thanks for the input everyone! Here are some answers: I do a lot of programming and gaming, so I do need things for both. The newer video card covers the gaming aspect, as well as allowing me to have many monitors. (hopefully upgrade to dual 30' or more) I don't need any additional HDs at this time. I have a SATA 160g and 120g from my previous computer, and a NAS system with over 2TB of storage on the homenetwork. I just wanted a fast HD for OS/programs/games. With the memory. I have used G.SKILL before in 2 system builds. It's done excellent for me in them. Very stable. **EDIT2: Made some additional changes. Lowered the power supply down to 750, which saves me more $$. Also changed the SSD to 2 WD 650G HDs. Thinking of doing a CPU upgrade to the 3.4GHZ AMD Phenom II X4 965 Black Edition Deneb 3.4GHz System Specs - Budget:$1500 CPU: AMD Phenom II X4 955 Black Edition Deneb 3.2GHz MB: GIGABYTE GA-MA790GPT-UD3H AM3 AMD 790GX HDMI ATX Memory: G.SKILL 4GB (2 x 2GB) 240-Pin DDR3 SDRAM DDR3 1333 (PC3 1066 Video: DIAMOND 5870PE51G Radeon HD 5870 (Cypress XT) 1GB 256-bit GD Power Supply: XCLIO GREATPOWER 1000W ATX12V SLI Ready CrossFire Ready HD:Intel X25-M Mainstream SSDSA2MH080G2C1 2.5" 80GB SATA II MLC Changes: Power Supply: CORSAIR CMPSU-750TX 750W ATX12V / EPS12V HD: 2x Western Digital Caviar Blue WD6400AAKS 640GB CPU: AMD Phenom II X4 965 Black Edition Deneb 3.4GHz

    Read the article

  • Will this RAID5 setup work (3TB Seagate Barracudas + Adaptec RAID 6405)?

    - by Slayer537
    As the title states, will this RAID combo work, and if not what needs to be changed? Overall opinions would be most helpful. I currently run a small file server of about 5TB or so. I keep outgrowing my needs and need to build a RAID setup that will allow me to expand as needed. I am new to RAID setups, especially one of the scale I have currently planned out, but I have being doing some research for the past couple of weeks and have come up with a build. Ideally, I'd have the setup completely built, but I'd like to keep the total cost around $1k and can't afford to go above $1.5k, so unfortunately that's not an option. 2 of my current drives are WD Caviar Blacks 2TB; however, I have recently learned that due to the lack of TLER those drives are awful for any RAID setup other than 0 or 1. That being said, my third drive is a Seagate Barracuda 3TB (ST300DM001) and I have found a RAID controller that states it supports it, so I'd like to use this same type of drive, if possible. Have any of you had any experience using this drive or a similar one in a RAID5 configuration? The manufacturer states that it supports it, but knowing that it is not an enterprise drive, I am slightly concerned that it could drop out of the array. I would just go with enterprise drives, but those are about double in cost... Parts list: Storage rack: http://www.ebay.com/itm/SGI-3U-Media-Storage-Server-16-Hard-Drive-Bay-SATA-SAS-Expander-Omnistor-SE3016-/140735776937?pt=LH_DefaultDomain_0&hash=item20c48188a9 3 more HDs (for now..): http://www.amazon.com/Seagate-Barracuda-3-5-Inch-Internal-ST3000DM001/dp/B005T3GRLY/ref=dp_return_2?ie=UTF8&n=172282&s=electronics Adaptec RAID 6405: http://www.newegg.com/Product/Product.aspx?Item=N82E16816103224 here's a link to the compatibility sheet if that helps: http://download.adaptec.com/pdfs/compatibility_report/arc-sas_cr_03-27-12_series6.pdf SAS expander cable: http://www.pc-pitstop.com/sas_cables_adapters/8887-2M.asp My plan is to install the RAID card in my computer and then route the SAS cable to the rack. Setup a RAID5 on 3 drives, transfer my data over from my other drive, and then add that drive to the array. Eventually, I'd like to get a 2U unit and run the file server on that and move the RAID card over to there, but that will have to happen later on. Side note: The computer the card would be going into will be running Windows 7 Pro with 24GB of DDR3-1600 and an i7-930.

    Read the article

  • How to connect SAN from CentOS through two iSCSI Targets

    - by garconcn
    I had asked the similar question before. This time I want to use subnet for two iSCSI Targets, hence I start a new question. I have an old Promise VTrak M500i SAN Server. It comes with 2 iSCSI ports. I want to connect to two LUNs on the SAN server through two separate Targets from CentOS 5.7 64bits server. My network setup is as follows: CentOS server: Management network - 192.168.1.1 Storage network 1 - 192.168.5.2 Storage network 2 - 192.168.6.2 Promise SAN server: Management network - 192.168.1.2 iSCSI Port 1 - 192.168.5.1 iSCSI Port 2 - 192.168.6.1 I have two Logical Drives on this SAN and they are mapped as follows: Index Initiator Name LUN Mapping 0 iqn.2011-11:backup (LD0,0) 1 iqn.2011-11:template (LD1,1) Basically, I want the traffic to iqn.2011-11:backup LUN 0 through 192.168.5.1 network the traffic to iqn.2011-11:template LUN 1 through 192.168.6.1 network I don't use MPIO, just want to separate the traffic to avoid traffic jam. How do I achieve this? I am new to SAN stuff, please explain as much detail as you can. Thank you. The following are what I am doing now. After mapping the LUN to my pre-defined Initiators, the CentOS server can discover both Targets. [root@centos ~]# iscsiadm -m discovery -t sendtargets -p 192.168.5.1 192.168.5.1:3260,1 iscsi-1 192.168.6.1:3260,2 iscsi-1 [root@centos ~]# iscsiadm -m discovery -t sendtargets -p 192.168.6.1 192.168.6.1:3260,2 iscsi-1 192.168.5.1:3260,1 iscsi-1 [root@centos ~]# /etc/init.d/iscsi start iscsid is stopped Starting iSCSI daemon: [ OK ] [ OK ] Setting up iSCSI targets: Logging in to [iface: default, target: iscsi-1, portal: 192.168.6.1,3260] Logging in to [iface: default, target: iscsi-1, portal: 192.168.5.1,3260] Login to [iface: default, target: iscsi-1, portal: 192.168.6.1,3260] successful. Login to [iface: default, target: iscsi-1, portal: 192.168.5.1,3260] successful. [ OK ] [root@centos ~]# iscsiadm -m session tcp: [1] 192.168.6.1:3260,2 iscsi-1 tcp: [2] 192.168.5.1:3260,1 iscsi-1 When I check the LUN mapping on the SAN server for the two Logical Drives, both LUNs are connected through Port0-192.168.5.2 with the Initiator defined in CentOS. Assigned Initiator List: Initiator Name Alias IP Address LUN iqn.2011-11.centos centos.mydomain.com Port0-192.168.5.2 0 Initiator Name Alias IP Address LUN iqn.2011-11.centos centos.mydomain.com Port1-192.168.5.2 1 I assume the following is what I want: Initiator Name Alias IP Address LUN iqn.2011-11.backup centos.mydomain.com Port0-192.168.5.2 0 Initiator Name Alias IP Address LUN iqn.2011-11.template centos.mydomain.com Port0-192.168.6.2 1

    Read the article

  • MySQL and PostgreSQL on the same hardware

    - by Kamil Kisiel
    We recently bought some new hardware for a database server which we were intending to dedicate to the operation of PostgreSQL. However now we have the requirement to also run MySQL as some software we want to use only supports that database. Since the storage on this machine is the most suitable for hosting a DB, and we don't currently have the budget for more hardware,we're thinking of running both of them on the same server. Are there any caveats or best practices we should be aware of?

    Read the article

  • HomeMade/DIY NAS solution

    - by MicTech
    Has anyone experience with building NAS (Network-attached storage) for home/small office using? What component would you recommend? Hardware CPU motherboard HDDs RAID controller etc. Software OS FTP HTTP etc.

    Read the article

  • MD3200 - 3 to 4x less throughput than MD1220. Am I missing something here?

    - by Igor Polishchuk
    I have two R710 servers with similar configuration. One in my office has MD1220 attached. Another one in the datacenter of my hosting services vendor has MD3200. I'm getting significantly worse throughput from MD3200 at my vendors setup. I'm mostly interested in sequential writes, and I'm getting these results in bonnie++ and dd tests: Seq. writes on MD1220 in my office: 1.1 GB/s - bonnie++, 1.3GB/s - dd Seq. writes on MD3200 at my vendor's: 240MB/s - bonnie++, 310MB/s - dd Unfortunately, I could not test the exactly the same configurations, but the two I have should be comparable. If anything, my good performing environment is cheaper than the bad performing. I expect at least similar throughput from these two setups. My vendor cannot really help me. Hopefully, somebody more familiar with the DAS performance can look at it and tell if I'm missing something here and my expectations are too high. To summarize, the question here is it reasonable to expect about 100MB/s of sequential write throughput per each couple of drives in RAID10 on MD3200? Is there any trick to enable such performance in MD3200 with dual controller as opposed to simple MD1220 with a single H800 adapter? More details about the configurations: A good one in my office: Dell R710 2CPU X5650 @ 2.67GHz 12 cores 96GB DDR3, OS: RHEL 5.5, kernel 2.6.18-194.26.1.el5 x86_64 20x300GB 2.5" SAS 10K in a single RAID10 1MB chunk size on MD1220 + Dell H800 I/O controller with 1GB cache in the host Not so good one at my vendor's: Dell R710 2CPU L5520 @ 2.27GHz 8 cores 144GB DDR3, OS: RHEL 5.5, kernel 2.6.18-194.11.4.el5 x86_64 20x146GB 2.5" SAS 15K in a single RAID10 512KB chunk size, Dell MD3200, 2 I/O controllers in array with 1GB cache each Additional information. I've also ran the same tests on the same vendor's host, but the storage was: two raids of 14x146GB 15K RPM drives RAID 10, striped together on the OS level on MD3000+MD1000. The performance was about 25% worse than on MD3200 despite having more drives. When I ran similar tests on the internal storage of my vendor's host (2x146GB 15K RPM drives RAID1, Perc 6i) I've got about 128MB/s seq. writes. Just two internal drives gave me about a half of 20 drives' throughput on MD3200. The random I/O performance of the MD3200 setup is ok, it gives me at least 1300 IOPS. I'm mostly have problems with sequentioal I/O throughput. Thank you for looking into it. Regards Igor

    Read the article

  • SMTP account without POP3/IMAP account in Thunderbird

    - by KP
    I'd like to set up Thunderbird to be able to send messages via an SMTP server, but I don't want to actually download any messages from a POP3 or IMAP account to Thunderbird's local storage. Is there any way to get Thunderbird to send messages without creating an incoming account? Currently, I'm unable to use the Write/Send features if I just have an outgoing server set up, but no incoming account.

    Read the article

  • IIS6 Virtual Directory 500 Error on Remote Share

    - by David
    We have our servers at the server farm in a domain. Let's call it LIVE. Our developer computers live in a completely separate corporate domain, miles and miles away. Let's call it CORP. We have a large central storage unit (unix) that houses images and other media needed by many webservers in the server farm. The IIS application pools run as (let's say) LIVE\MediaUser and use those credentials to connect to a central storage share as a virtual directory, retrieve the images, and serve them as if they were local on each server. The problem is in development. On my development machine. I log in as CORP\MyName. My IIS 6 application pool runs as Network Service. I can't run it as a user from the LIVE domain because my machine isn't (and can not be) joined to that domain. I try to create a virtual directory, point it to the same network directory, click Connect As, uncheck the "Always use the authenticated user's credentials when validating access to the network directory" checkbox so that I can enter the login info, enter the credentails for LIVE\MediaUser, click OK, verify the password, etc. This doesn't work. I get "HTTP Error 500 - Internal server error" from IIS. The IIS log file reports sc-status = 500, sc-substatus = 16, and sc-win32-status = 1326. The documentation says this means "UNC authorization credentials are incorrect" and the Win32 status means "Logon failure: unknown user name or bad password." This would be all and good if it were anywhere close to accurate. I double- and trouble-checked it. Tried multiple known good logins. The IIS manager allows me to view the file tree in its window, it's only the browser that kicks me out. I even tried going to the virtual directory's Directory Security tab, and under Authentication and Access Control, I tried using the same LIVE domain username for the anonymous access credential. No luck. I'm not trying to run any ASP, ASP.NET, or other dynamic anything out of the virtual directory. I just want IIS to be able to load static images, css, and js files. If anyone has some bright ideas I would be most appreciative!

    Read the article

  • MySQL daemon keeps terminating unexpectedly

    - by Yehia A.Salam
    The MySQL daemon on my CentOS server keeps crashing, i got the logs from /var/logs/mysqld but still i am not sure how to fix this: 121114 16:22:56 mysqld_safe mysqld from pid file /var/run/mysqld/mysqld.pid ended 121114 21:55:11 mysqld_safe Starting mysqld daemon with databases from /var/lib/mysql 121114 21:55:11 [Note] Plugin 'FEDERATED' is disabled. 121114 21:55:11 InnoDB: The InnoDB memory heap is disabled 121114 21:55:11 InnoDB: Mutexes and rw_locks use GCC atomic builtins 121114 21:55:11 InnoDB: Compressed tables use zlib 1.2.3 121114 21:55:11 InnoDB: Using Linux native AIO 121114 21:55:11 InnoDB: Initializing buffer pool, size = 128.0M 121114 21:55:11 InnoDB: Completed initialization of buffer pool 121114 21:55:11 InnoDB: highest supported file format is Barracuda. InnoDB: The log sequence number in ibdata files does not match InnoDB: the log sequence number in the ib_logfiles! 121114 21:55:11 InnoDB: Database was not shut down normally! InnoDB: Starting crash recovery. InnoDB: Reading tablespace information from the .ibd files... InnoDB: Restoring possible half-written data pages from the doublewrite InnoDB: buffer... 121114 21:55:12 InnoDB: Waiting for the background threads to start 121114 21:55:13 InnoDB: 1.1.6 started; log sequence number 77177262 121114 21:55:13 [Note] Event Scheduler: Loaded 0 events 121114 21:55:13 [Note] /usr/libexec/mysqld: ready for connections. Version: '5.5.12' socket: '/var/lib/mysql/mysql.sock' port: 3306 MySQL Community Server (GPL) by Remi 121115 00:19:44 mysqld_safe Number of processes running now: 0 121115 00:19:44 mysqld_safe mysqld restarted 121115 0:19:47 [Note] Plugin 'FEDERATED' is disabled. 121115 0:19:47 InnoDB: The InnoDB memory heap is disabled 121115 0:19:47 InnoDB: Mutexes and rw_locks use GCC atomic builtins 121115 0:19:47 InnoDB: Compressed tables use zlib 1.2.3 121115 0:19:47 InnoDB: Using Linux native AIO 121115 0:19:47 InnoDB: Initializing buffer pool, size = 128.0M InnoDB: mmap(137363456 bytes) failed; errno 12 121115 0:19:47 InnoDB: Completed initialization of buffer pool 121115 0:19:47 InnoDB: Fatal error: cannot allocate memory for the buffer pool 121115 0:19:47 [ERROR] Plugin 'InnoDB' init function returned error. 121115 0:19:47 [ERROR] Plugin 'InnoDB' registration as a STORAGE ENGINE failed. 121115 0:19:47 [ERROR] Unknown/unsupported storage engine: InnoDB 121115 0:19:47 [ERROR] Aborting Edit #1 total used free shared buffers cached Mem: 496 370 126 0 24 110 -/+ buffers/cache: 234 261 Swap: 1023 9 1014 Edit #2 Also, largest table in my mysql is 20MB, so my the memory used should be pretty moderate. SELECT CONCAT(table_schema, '.', table_name), CONCAT(ROUND(table_rows / 1000000, 2), 'M') rows, CONCAT(ROUND(data_length / ( 1024 * 1024 * 1024 ), 2), 'G') DATA, CONCAT(ROUND(index_length / ( 1024 * 1024 * 1024 ), 2), 'G') idx, CONCAT(ROUND(( data_length + index_length ) / ( 1024 * 1024 * 1024 ), 2), 'G') total_size, ROUND(index_length / data_length, 2) idxfrac FROM information_schema.TABLES ORDER BY data_length + index_length DESC LIMIT 10;

    Read the article

  • How to restore a VirtualBox image given the .vdi file

    - by Ramon Tayag
    Background I have VirtualBox on Linux and recently the drive with the system files failed on me. I'm able to use the Live CD to view the files of the storage drive, and through this, I can copy my data files to another computer while I work on this one. How do I load the .vdi in another computer (or in this case, the fresh install of Ubuntu)? I see many samples online of how to export it, but it assumes the host is currently working. Thanks!

    Read the article

  • Garbled text in Screen [closed]

    - by Prabin Dahal
    The graphical Interface in my system is garbled with some text. At the beginning I thought it was due to java and tomcat that I installed. But after removing java and tomcat, it is still the same. I am using ubuntu server and i have installed xfce desktop environment with oboard softkey I have added my dmesg output to this message. What is the problem here. I am not able to figure it out. Thank you for your help. Prabin [ 0.390936] usbcore: registered new interface driver usbfs [ 0.391006] usbcore: registered new interface driver hub [ 0.391147] usbcore: registered new device driver usb [ 0.391580] PCI: Using ACPI for IRQ routing [ 0.400509] PCI: pci_cache_line_size set to 64 bytes [ 0.400669] reserve RAM buffer: 000000000009ec00 - 000000000009ffff [ 0.400681] reserve RAM buffer: 000000007f597000 - 000000007fffffff [ 0.400699] reserve RAM buffer: 000000007f6f0000 - 000000007fffffff [ 0.401135] NetLabel: Initializing [ 0.401155] NetLabel: domain hash size = 128 [ 0.401168] NetLabel: protocols = UNLABELED CIPSOv4 [ 0.401212] NetLabel: unlabeled traffic allowed by default [ 0.401466] HPET: 3 timers in total, 0 timers will be used for per-cpu timer [ 0.401494] hpet0: at MMIO 0xfed00000, IRQs 2, 8, 0 [ 0.401520] hpet0: 3 comparators, 64-bit 14.318180 MHz counter [ 0.408228] Switching to clocksource hpet [ 0.434341] AppArmor: AppArmor Filesystem Enabled [ 0.434447] pnp: PnP ACPI init [ 0.434531] ACPI: bus type pnp registered [ 0.434784] pnp 00:00: [bus 00-ff] [ 0.434794] pnp 00:00: [io 0x0cf8-0x0cff] [ 0.434804] pnp 00:00: [io 0x0000-0x0cf7 window] [ 0.434813] pnp 00:00: [io 0x0d00-0xffff window] [ 0.434822] pnp 00:00: [mem 0x000a0000-0x000bffff window] [ 0.434831] pnp 00:00: [mem 0x00000000 window] [ 0.434840] pnp 00:00: [mem 0x80000000-0xffffffff window] [ 0.435018] pnp 00:00: Plug and Play ACPI device, IDs PNP0a08 PNP0a03 (active) [ 0.435526] pnp 00:01: [mem 0xe0000000-0xefffffff] [ 0.435537] pnp 00:01: [mem 0x7f700000-0x7f7fffff] [ 0.435545] pnp 00:01: [mem 0x7f800000-0x7fffffff] [ 0.435554] pnp 00:01: [mem 0xfee00000-0xfeefffff] [ 0.435727] system 00:01: [mem 0xe0000000-0xefffffff] has been reserved [ 0.435754] system 00:01: [mem 0x7f700000-0x7f7fffff] has been reserved [ 0.435775] system 00:01: [mem 0x7f800000-0x7fffffff] has been reserved [ 0.435796] system 00:01: [mem 0xfee00000-0xfeefffff] has been reserved [ 0.435818] system 00:01: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.436233] pnp 00:02: [io 0x0000-0xffffffffffffffff disabled] [ 0.436245] pnp 00:02: [io 0x0000-0xffffffffffffffff disabled] [ 0.436414] system 00:02: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.436512] pnp 00:03: [io 0x0060] [ 0.436521] pnp 00:03: [io 0x0064] [ 0.436548] pnp 00:03: [irq 1] [ 0.436682] pnp 00:03: Plug and Play ACPI device, IDs PNP0303 PNP030b (active) [ 0.436825] pnp 00:04: [irq 12] [ 0.436958] pnp 00:04: Plug and Play ACPI device, IDs PNP0f03 PNP0f13 (active) [ 0.437835] pnp 00:05: [io 0x03f8-0x03ff] [ 0.437861] pnp 00:05: [irq 4] [ 0.437870] pnp 00:05: [dma 0 disabled] [ 0.438142] pnp 00:05: Plug and Play ACPI device, IDs PNP0501 (active) [ 0.439014] pnp 00:06: [io 0x02f8-0x02ff] [ 0.439036] pnp 00:06: [irq 3] [ 0.439045] pnp 00:06: [dma 0 disabled] [ 0.439297] pnp 00:06: Plug and Play ACPI device, IDs PNP0501 (active) [ 0.439346] pnp 00:07: [io 0x0000-0x000f] [ 0.439355] pnp 00:07: [io 0x0081-0x0083] [ 0.439363] pnp 00:07: [io 0x0087] [ 0.439371] pnp 00:07: [io 0x0089-0x008b] [ 0.439380] pnp 00:07: [io 0x008f] [ 0.439388] pnp 00:07: [io 0x00c0-0x00df] [ 0.439563] system 00:07: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.439617] pnp 00:08: [io 0x0070-0x0077] [ 0.439639] pnp 00:08: [irq 8] [ 0.439751] pnp 00:08: Plug and Play ACPI device, IDs PNP0b00 (active) [ 0.439788] pnp 00:09: [io 0x0061] [ 0.439893] pnp 00:09: Plug and Play ACPI device, IDs PNP0800 (active) [ 0.439977] pnp 00:0a: [io 0x0010-0x001f] [ 0.439986] pnp 00:0a: [io 0x0022-0x003f] [ 0.439994] pnp 00:0a: [io 0x0044-0x005f] [ 0.440055] pnp 00:0a: [io 0x0063] [ 0.440063] pnp 00:0a: [io 0x0065] [ 0.440071] pnp 00:0a: [io 0x0067-0x006f] [ 0.440079] pnp 00:0a: [io 0x0072-0x007f] [ 0.440086] pnp 00:0a: [io 0x0080] [ 0.440094] pnp 00:0a: [io 0x0084-0x0086] [ 0.440102] pnp 00:0a: [io 0x0088] [ 0.440109] pnp 00:0a: [io 0x008c-0x008e] [ 0.440117] pnp 00:0a: [io 0x0090-0x009f] [ 0.440125] pnp 00:0a: [io 0x00a2-0x00bf] [ 0.440133] pnp 00:0a: [io 0x00e0-0x00ef] [ 0.440141] pnp 00:0a: [io 0x04d0-0x04d1] [ 0.440150] pnp 00:0a: [io 0x0000-0xffffffffffffffff disabled] [ 0.440160] pnp 00:0a: [io 0x0000-0xffffffffffffffff disabled] [ 0.440168] pnp 00:0a: [io 0x03f4] [ 0.440175] pnp 00:0a: [io 0x03f5] [ 0.440183] pnp 00:0a: [io 0x0374] [ 0.440190] pnp 00:0a: [io 0x0375] [ 0.440405] system 00:0a: [io 0x04d0-0x04d1] has been reserved [ 0.440432] system 00:0a: [io 0x03f4] has been reserved [ 0.440451] system 00:0a: [io 0x03f5] has been reserved [ 0.440469] system 00:0a: [io 0x0374] has been reserved [ 0.440488] system 00:0a: [io 0x0375] has been reserved [ 0.440508] system 00:0a: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.440550] pnp 00:0b: [io 0x00f0-0x00ff] [ 0.440572] pnp 00:0b: [irq 13] [ 0.440691] pnp 00:0b: Plug and Play ACPI device, IDs PNP0c04 (active) [ 0.440770] pnp 00:0c: [io 0x0810] [ 0.440779] pnp 00:0c: [io 0x0800-0x080f] [ 0.440787] pnp 00:0c: [io 0xffff] [ 0.440947] system 00:0c: [io 0x0810] has been reserved [ 0.440970] system 00:0c: [io 0x0800-0x080f] has been reserved [ 0.440989] system 00:0c: [io 0xffff] has been reserved [ 0.441010] system 00:0c: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.441620] pnp 00:0d: [io 0x0900-0x097f] [ 0.441630] pnp 00:0d: [io 0x09c0-0x09ff] [ 0.441639] pnp 00:0d: [io 0x0400-0x043f] [ 0.441647] pnp 00:0d: [io 0x0480-0x04bf] [ 0.441656] pnp 00:0d: [mem 0xfec00000-0xfec85fff] [ 0.441664] pnp 00:0d: [mem 0xfed1c000-0xfed1ffff] [ 0.441673] pnp 00:0d: [mem 0x000c0000-0x000dffff] [ 0.441689] pnp 00:0d: [mem 0x000e0000-0x000effff] [ 0.441697] pnp 00:0d: [mem 0x000f0000-0x000fffff] [ 0.441706] pnp 00:0d: [mem 0xff800000-0xffffffff] [ 0.441911] system 00:0d: [io 0x0900-0x097f] has been reserved [ 0.441935] system 00:0d: [io 0x09c0-0x09ff] has been reserved [ 0.441955] system 00:0d: [io 0x0400-0x043f] has been reserved [ 0.441975] system 00:0d: [io 0x0480-0x04bf] has been reserved [ 0.441997] system 00:0d: [mem 0xfec00000-0xfec85fff] could not be reserved [ 0.442019] system 00:0d: [mem 0xfed1c000-0xfed1ffff] has been reserved [ 0.442040] system 00:0d: [mem 0x000c0000-0x000dffff] could not be reserved [ 0.442061] system 00:0d: [mem 0x000e0000-0x000effff] could not be reserved [ 0.442082] system 00:0d: [mem 0x000f0000-0x000fffff] could not be reserved [ 0.442103] system 00:0d: [mem 0xff800000-0xffffffff] has been reserved [ 0.442126] system 00:0d: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.442308] pnp 00:0e: [mem 0xfed00000-0xfed003ff] [ 0.442454] pnp 00:0e: Plug and Play ACPI device, IDs PNP0103 (active) [ 0.442569] pnp 00:0f: [mem 0x7f6f0000-0x7f6fffff] [ 0.442762] system 00:0f: [mem 0x7f6f0000-0x7f6fffff] has been reserved [ 0.442788] system 00:0f: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.443360] pnp: PnP ACPI: found 16 devices [ 0.443378] ACPI: ACPI bus type pnp unregistered [ 0.443395] PnPBIOS: Disabled by ACPI PNP [ 0.486106] PCI: max bus depth: 3 pci_try_num: 4 [ 0.486189] pci 0000:00:1c.0: PCI bridge to [bus 01-01] [ 0.486217] pci 0000:00:1c.0: bridge window [io 0xe000-0xefff] [ 0.486241] pci 0000:00:1c.0: bridge window [mem 0xd0100000-0xd01fffff] [ 0.486266] pci 0000:00:1c.0: bridge window [mem 0xff700000-0xff7fffff pref] [ 0.486298] pci 0000:03:01.0: PCI bridge to [bus 04-04] [ 0.486319] pci 0000:03:01.0: bridge window [io 0xd000-0xdfff] [ 0.486348] pci 0000:03:01.0: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486374] pci 0000:03:01.0: bridge window [mem 0xff600000-0xff6fffff 64bit pref] [ 0.486406] pci 0000:03:02.0: PCI bridge to [bus 05-05] [ 0.486444] pci 0000:03:03.0: PCI bridge to [bus 06-06] [ 0.486479] pci 0000:02:00.0: PCI bridge to [bus 03-06] [ 0.486499] pci 0000:02:00.0: bridge window [io 0xd000-0xdfff] [ 0.486522] pci 0000:02:00.0: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486545] pci 0000:02:00.0: bridge window [mem 0xff600000-0xff6fffff 64bit pref] [ 0.486575] pci 0000:00:1c.1: PCI bridge to [bus 02-06] [ 0.486593] pci 0000:00:1c.1: bridge window [io 0xd000-0xdfff] [ 0.486615] pci 0000:00:1c.1: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486637] pci 0000:00:1c.1: bridge window [mem 0xff600000-0xff6fffff pref] [ 0.486710] pci 0000:00:1c.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 0.486735] pci 0000:00:1c.0: setting latency timer to 64 [ 0.486774] pci 0000:00:1c.1: PCI INT B -> GSI 17 (level, low) -> IRQ 17 [ 0.486796] pci 0000:00:1c.1: setting latency timer to 64 [ 0.486817] pci 0000:02:00.0: setting latency timer to 64 [ 0.486836] pci 0000:03:01.0: setting latency timer to 64 [ 0.486858] pci 0000:03:02.0: setting latency timer to 64 [ 0.486880] pci 0000:03:03.0: setting latency timer to 64 [ 0.486893] pci_bus 0000:00: resource 4 [io 0x0000-0x0cf7] [ 0.486902] pci_bus 0000:00: resource 5 [io 0x0d00-0xffff] [ 0.486912] pci_bus 0000:00: resource 6 [mem 0x000a0000-0x000bffff] [ 0.486922] pci_bus 0000:00: resource 7 [mem 0x80000000-0xffffffff] [ 0.486932] pci_bus 0000:01: resource 0 [io 0xe000-0xefff] [ 0.486941] pci_bus 0000:01: resource 1 [mem 0xd0100000-0xd01fffff] [ 0.486951] pci_bus 0000:01: resource 2 [mem 0xff700000-0xff7fffff pref] [ 0.486961] pci_bus 0000:02: resource 0 [io 0xd000-0xdfff] [ 0.486970] pci_bus 0000:02: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.486980] pci_bus 0000:02: resource 2 [mem 0xff600000-0xff6fffff pref] [ 0.486989] pci_bus 0000:03: resource 0 [io 0xd000-0xdfff] [ 0.486998] pci_bus 0000:03: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.487008] pci_bus 0000:03: resource 2 [mem 0xff600000-0xff6fffff 64bit pref] [ 0.487018] pci_bus 0000:04: resource 0 [io 0xd000-0xdfff] [ 0.487028] pci_bus 0000:04: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.487038] pci_bus 0000:04: resource 2 [mem 0xff600000-0xff6fffff 64bit pref] [ 0.487177] NET: Registered protocol family 2 [ 0.487405] IP route cache hash table entries: 32768 (order: 5, 131072 bytes) [ 0.488397] TCP established hash table entries: 131072 (order: 8, 1048576 bytes) [ 0.489792] TCP bind hash table entries: 65536 (order: 7, 524288 bytes) [ 0.490493] TCP: Hash tables configured (established 131072 bind 65536) [ 0.490525] TCP reno registered [ 0.490551] UDP hash table entries: 512 (order: 2, 16384 bytes) [ 0.490590] UDP-Lite hash table entries: 512 (order: 2, 16384 bytes) [ 0.490898] NET: Registered protocol family 1 [ 0.490970] pci 0000:00:02.0: Boot video device [ 0.491052] pci 0000:00:1d.0: PCI INT A -> GSI 20 (level, low) -> IRQ 20 [ 0.491092] pci 0000:00:1d.0: PCI INT A disabled [ 0.491134] pci 0000:00:1d.1: PCI INT B -> GSI 21 (level, low) -> IRQ 21 [ 0.491174] pci 0000:00:1d.1: PCI INT B disabled [ 0.491220] pci 0000:00:1d.2: PCI INT C -> GSI 22 (level, low) -> IRQ 22 [ 0.491259] pci 0000:00:1d.2: PCI INT C disabled [ 0.491307] pci 0000:00:1d.7: PCI INT D -> GSI 23 (level, low) -> IRQ 23 [ 0.864431] Freeing initrd memory: 13820k freed [ 2.088042] pci 0000:00:1d.7: EHCI: BIOS handoff failed (BIOS bug?) 01010001 [ 2.088207] pci 0000:00:1d.7: PCI INT D disabled [ 2.088267] PCI: CLS 64 bytes, default 64 [ 2.089248] audit: initializing netlink socket (disabled) [ 2.089287] type=2000 audit(1349363630.084:1): initialized [ 2.144783] highmem bounce pool size: 64 pages [ 2.144808] HugeTLB registered 2 MB page size, pre-allocated 0 pages [ 2.160057] VFS: Disk quotas dquot_6.5.2 [ 2.160232] Dquot-cache hash table entries: 1024 (order 0, 4096 bytes) [ 2.161716] fuse init (API version 7.17) [ 2.161995] msgmni has been set to 1713 [ 2.162925] Block layer SCSI generic (bsg) driver version 0.4 loaded (major 253) [ 2.163008] io scheduler noop registered [ 2.163023] io scheduler deadline registered [ 2.163048] io scheduler cfq registered (default) [ 2.163339] pcieport 0000:00:1c.0: setting latency timer to 64 [ 2.163530] pcieport 0000:00:1c.1: setting latency timer to 64 [ 2.163706] pcieport 0000:02:00.0: setting latency timer to 64 [ 2.163873] pcieport 0000:03:01.0: setting latency timer to 64 [ 2.163964] pcieport 0000:03:01.0: irq 40 for MSI/MSI-X [ 2.164193] pcieport 0000:03:02.0: setting latency timer to 64 [ 2.164272] pcieport 0000:03:02.0: irq 41 for MSI/MSI-X [ 2.164453] pcieport 0000:03:03.0: setting latency timer to 64 [ 2.164531] pcieport 0000:03:03.0: irq 42 for MSI/MSI-X [ 2.164783] pcieport 0000:00:1c.0: Signaling PME through PCIe PME interrupt [ 2.164801] pci 0000:01:00.0: Signaling PME through PCIe PME interrupt [ 2.164816] pcie_pme 0000:00:1c.0:pcie01: service driver pcie_pme loaded [ 2.164853] pcieport 0000:00:1c.1: Signaling PME through PCIe PME interrupt [ 2.164867] pcieport 0000:02:00.0: Signaling PME through PCIe PME interrupt [ 2.164880] pcieport 0000:03:01.0: Signaling PME through PCIe PME interrupt [ 2.164892] pci 0000:04:00.0: Signaling PME through PCIe PME interrupt [ 2.164904] pcieport 0000:03:02.0: Signaling PME through PCIe PME interrupt [ 2.164917] pcieport 0000:03:03.0: Signaling PME through PCIe PME interrupt [ 2.164932] pcie_pme 0000:00:1c.1:pcie01: service driver pcie_pme loaded [ 2.164988] pci_hotplug: PCI Hot Plug PCI Core version: 0.5 [ 2.165115] pciehp 0000:00:1c.0:pcie04: HPC vendor_id 8086 device_id 8110 ss_vid 8086 ss_did 8119 [ 2.165177] pciehp 0000:00:1c.0:pcie04: service driver pciehp loaded [ 2.165199] pciehp 0000:00:1c.1:pcie04: HPC vendor_id 8086 device_id 8112 ss_vid 8086 ss_did 8119 [ 2.165260] pciehp 0000:00:1c.1:pcie04: service driver pciehp loaded [ 2.165290] pciehp: PCI Express Hot Plug Controller Driver version: 0.4 [ 2.165488] intel_idle: MWAIT substates: 0x3020220 [ 2.165508] intel_idle: v0.4 model 0x1C [ 2.165513] intel_idle: lapic_timer_reliable_states 0x2 [ 2.165519] Marking TSC unstable due to TSC halts in idle states deeper than C2 [ 2.165779] input: Lid Switch as /devices/LNXSYSTM:00/device:00/PNP0C0D:00/input/input0 [ 2.165855] ACPI: Lid Switch [LID] [ 2.165983] input: Power Button as /devices/LNXSYSTM:00/device:00/PNP0C0C:00/input/input1 [ 2.166005] ACPI: Power Button [PWRB] [ 2.173811] thermal LNXTHERM:00: registered as thermal_zone0 [ 2.173829] ACPI: Thermal Zone [TZ00] (48 C) [ 2.174004] thermal LNXTHERM:01: registered as thermal_zone1 [ 2.174018] ACPI: Thermal Zone [TZ01] (34 C) [ 2.174194] thermal LNXTHERM:02: registered as thermal_zone2 [ 2.174207] ACPI: Thermal Zone [TZ02] (34 C) [ 2.174378] thermal LNXTHERM:03: registered as thermal_zone3 [ 2.174392] ACPI: Thermal Zone [TZ03] (34 C) [ 2.174503] ERST: Table is not found! [ 2.174513] GHES: HEST is not enabled! [ 2.174601] isapnp: Scanning for PnP cards... [ 2.176175] Serial: 8250/16550 driver, 32 ports, IRQ sharing enabled [ 2.196702] serial8250: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 2.292409] serial8250: ttyS1 at I/O 0x2f8 (irq = 3) is a 16550A [ 2.528909] isapnp: No Plug & Play device found [ 2.588733] 00:05: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 2.624523] 00:06: ttyS1 at I/O 0x2f8 (irq = 3) is a 16550A [ 2.640702] Linux agpgart interface v0.103 [ 2.645138] brd: module loaded [ 2.647452] loop: module loaded [ 2.648149] pata_acpi 0000:00:1f.1: setting latency timer to 64 [ 2.649238] Fixed MDIO Bus: probed [ 2.649315] tun: Universal TUN/TAP device driver, 1.6 [ 2.649327] tun: (C) 1999-2004 Max Krasnyansky <[email protected]> [ 2.649524] PPP generic driver version 2.4.2 [ 2.649824] ehci_hcd: USB 2.0 'Enhanced' Host Controller (EHCI) Driver [ 2.649884] ehci_hcd 0000:00:1d.7: PCI INT D -> GSI 23 (level, low) -> IRQ 23 [ 2.649937] ehci_hcd 0000:00:1d.7: setting latency timer to 64 [ 2.649946] ehci_hcd 0000:00:1d.7: EHCI Host Controller [ 2.650082] ehci_hcd 0000:00:1d.7: new USB bus registered, assigned bus number 1 [ 2.650148] ehci_hcd 0000:00:1d.7: debug port 1 [ 2.654045] ehci_hcd 0000:00:1d.7: cache line size of 64 is not supported [ 2.654093] ehci_hcd 0000:00:1d.7: irq 23, io mem 0xd02c4000 [ 2.668035] ehci_hcd 0000:00:1d.7: USB 2.0 started, EHCI 1.00 [ 2.668392] hub 1-0:1.0: USB hub found [ 2.668413] hub 1-0:1.0: 8 ports detected [ 2.668618] ohci_hcd: USB 1.1 'Open' Host Controller (OHCI) Driver [ 2.668666] uhci_hcd: USB Universal Host Controller Interface driver [ 2.668726] uhci_hcd 0000:00:1d.0: PCI INT A -> GSI 20 (level, low) -> IRQ 20 [ 2.668751] uhci_hcd 0000:00:1d.0: setting latency timer to 64 [ 2.668759] uhci_hcd 0000:00:1d.0: UHCI Host Controller [ 2.668910] uhci_hcd 0000:00:1d.0: new USB bus registered, assigned bus number 2 [ 2.668981] uhci_hcd 0000:00:1d.0: irq 20, io base 0x0000f040 [ 2.669335] hub 2-0:1.0: USB hub found [ 2.669355] hub 2-0:1.0: 2 ports detected [ 2.669508] uhci_hcd 0000:00:1d.1: PCI INT B -> GSI 21 (level, low) -> IRQ 21 [ 2.669531] uhci_hcd 0000:00:1d.1: setting latency timer to 64 [ 2.669538] uhci_hcd 0000:00:1d.1: UHCI Host Controller [ 2.669675] uhci_hcd 0000:00:1d.1: new USB bus registered, assigned bus number 3 [ 2.669739] uhci_hcd 0000:00:1d.1: irq 21, io base 0x0000f020 [ 2.670099] hub 3-0:1.0: USB hub found [ 2.670118] hub 3-0:1.0: 2 ports detected [ 2.670271] uhci_hcd 0000:00:1d.2: PCI INT C -> GSI 22 (level, low) -> IRQ 22 [ 2.670295] uhci_hcd 0000:00:1d.2: setting latency timer to 64 [ 2.670302] uhci_hcd 0000:00:1d.2: UHCI Host Controller [ 2.670435] uhci_hcd 0000:00:1d.2: new USB bus registered, assigned bus number 4 [ 2.670502] uhci_hcd 0000:00:1d.2: irq 22, io base 0x0000f000 [ 2.670869] hub 4-0:1.0: USB hub found [ 2.670888] hub 4-0:1.0: 2 ports detected [ 2.671186] usbcore: registered new interface driver libusual [ 2.671332] i8042: PNP: PS/2 Controller [PNP0303:PS2K,PNP0f03:PS2M] at 0x60,0x64 irq 1,12 [ 2.673408] serio: i8042 KBD port at 0x60,0x64 irq 1 [ 2.673437] serio: i8042 AUX port at 0x60,0x64 irq 12 [ 2.673844] mousedev: PS/2 mouse device common for all mice [ 2.674272] rtc_cmos 00:08: RTC can wake from S4 [ 2.674482] rtc_cmos 00:08: rtc core: registered rtc_cmos as rtc0 [ 2.674529] rtc0: alarms up to one year, y3k, 242 bytes nvram, hpet irqs [ 2.674691] device-mapper: uevent: version 1.0.3 [ 2.674903] device-mapper: ioctl: 4.22.0-ioctl (2011-10-19) initialised: [email protected] [ 2.675024] EISA: Probing bus 0 at eisa.0 [ 2.675037] EISA: Cannot allocate resource for mainboard [ 2.675050] Cannot allocate resource for EISA slot 1 [ 2.675061] Cannot allocate resource for EISA slot 2 [ 2.675072] Cannot allocate resource for EISA slot 3 [ 2.675083] Cannot allocate resource for EISA slot 4 [ 2.675094] Cannot allocate resource for EISA slot 5 [ 2.675105] Cannot allocate resource for EISA slot 6 [ 2.675116] Cannot allocate resource for EISA slot 7 [ 2.675127] Cannot allocate resource for EISA slot 8 [ 2.675137] EISA: Detected 0 cards. [ 2.675161] cpufreq-nforce2: No nForce2 chipset. [ 2.675401] cpuidle: using governor ladder [ 2.675786] cpuidle: using governor menu [ 2.675797] EFI Variables Facility v0.08 2004-May-17 [ 2.676429] TCP cubic registered [ 2.676751] NET: Registered protocol family 10 [ 2.678031] NET: Registered protocol family 17 [ 2.678052] Registering the dns_resolver key type [ 2.678107] Using IPI No-Shortcut mode [ 2.678515] PM: Hibernation image not present or could not be loaded. [ 2.678543] registered taskstats version 1 [ 2.701145] Magic number: 0:84:234 [ 2.701312] rtc_cmos 00:08: setting system clock to 2012-10-04 15:13:51 UTC (1349363631) [ 2.702280] BIOS EDD facility v0.16 2004-Jun-25, 0 devices found [ 2.702294] EDD information not available. [ 2.702858] Freeing unused kernel memory: 740k freed [ 2.703630] Write protecting the kernel text: 5816k [ 2.703692] Write protecting the kernel read-only data: 2376k [ 2.703706] NX-protecting the kernel data: 4424k [ 2.751226] udevd[84]: starting version 175 [ 2.980162] usb 1-1: new high-speed USB device number 2 using ehci_hcd [ 3.001394] r8169 Gigabit Ethernet driver 2.3LK-NAPI loaded [ 3.001474] r8169 0000:01:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 3.001554] r8169 0000:01:00.0: setting latency timer to 64 [ 3.001654] r8169 0000:01:00.0: irq 43 for MSI/MSI-X [ 3.004220] r8169 0000:01:00.0: eth0: RTL8168c/8111c at 0xf8416000, 00:18:92:03:10:46, XID 1c4000c0 IRQ 43 [ 3.004254] r8169 0000:01:00.0: eth0: jumbo features [frames: 6128 bytes, tx checksumming: ko] [ 3.004347] r8169 Gigabit Ethernet driver 2.3LK-NAPI loaded [ 3.005085] r8169 0000:04:00.0: PCI INT A -> GSI 18 (level, low) -> IRQ 18 [ 3.005182] r8169 0000:04:00.0: setting latency timer to 64 [ 3.005292] r8169 0000:04:00.0: irq 44 for MSI/MSI-X [ 3.007187] r8169 0000:04:00.0: eth1: RTL8168c/8111c at 0xf8418000, 00:18:92:03:10:47, XID 1c4000c0 IRQ 44 [ 3.007224] r8169 0000:04:00.0: eth1: jumbo features [frames: 6128 bytes, tx checksumming: ko] [ 3.034417] pata_sch 0000:00:1f.1: version 0.2 [ 3.034518] pata_sch 0000:00:1f.1: setting latency timer to 64 [ 3.036698] scsi0 : pata_sch [ 3.039842] scsi1 : pata_sch [ 3.040913] ata1: PATA max UDMA/100 cmd 0x1f0 ctl 0x3f6 bmdma 0xf060 irq 14 [ 3.040940] ata2: PATA max UDMA/100 cmd 0x170 ctl 0x376 bmdma 0xf068 irq 15 [ 3.131850] Initializing USB Mass Storage driver... [ 3.136405] scsi2 : usb-storage 1-1:1.0 [ 3.136642] usbcore: registered new interface driver usb-storage [ 3.136656] USB Mass Storage support registered. [ 3.524465] usb 3-1: new low-speed USB device number 2 using uhci_hcd [ 3.968144] usb 3-2: new full-speed USB device number 3 using uhci_hcd [ 4.137903] scsi 2:0:0:0: Direct-Access TS TS4GUFM-H 1100 PQ: 0 ANSI: 0 CCS [ 4.140067] sd 2:0:0:0: Attached scsi generic sg0 type 0 [ 4.140590] sd 2:0:0:0: [sda] 8028160 512-byte logical blocks: (4.11 GB/3.82 GiB) [ 4.141597] sd 2:0:0:0: [sda] Write Protect is off [ 4.141618] sd 2:0:0:0: [sda] Mode Sense: 43 00 00 00 [ 4.142974] sd 2:0:0:0: [sda] No Caching mode page present [ 4.143000] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.145837] sd 2:0:0:0: [sda] No Caching mode page present [ 4.145858] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.147931] sda: sda1 sda2 < sda5 > [ 4.150972] sd 2:0:0:0: [sda] No Caching mode page present [ 4.151001] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.151023] sd 2:0:0:0: [sda] Attached SCSI disk [ 4.249168] input: HID 046a:004b as /devices/pci0000:00/0000:00:1d.1/usb3/3-1/3-1:1.0/input/input2 [ 4.249579] generic-usb 0003:046A:004B.0001: input,hidraw0: USB HID v1.11 Keyboard [HID 046a:004b] on usb-0000:00:1d.1-1/input0 [ 4.287805] input: HID 046a:004b as /devices/pci0000:00/0000:00:1d.1/usb3/3-1/3-1:1.1/input/input3 [ 4.289235] generic-usb 0003:046A:004B.0002: input,hidraw1: USB HID v1.11 Mouse [HID 046a:004b] on usb-0000:00:1d.1-1/input1 [ 4.297604] input: EloTouchSystems,Inc Elo TouchSystems 2216 AccuTouch\xffffffc2\xffffffae\xffffffae USB Touchmonitor Interface as /devices/pci0000:00/0000:00:1d.1/usb3/3-2/3-2:1.0/input/input4 [ 4.298913] generic-usb 0003:04E7:0050.0003: input,hidraw2: USB HID v1.00 Pointer [EloTouchSystems,Inc Elo TouchSystems 2216 AccuTouch\xffffffc2\xffffffae\xffffffae USB Touchmonitor Interface] on usb-0000:00:1d.1-2/input0 [ 4.299878] usbcore: registered new interface driver usbhid [ 4.299925] usbhid: USB HID core driver [ 4.352639] EXT4-fs (sda1): INFO: recovery required on readonly filesystem [ 4.352661] EXT4-fs (sda1): write access will be enabled during recovery [ 8.519257] EXT4-fs (sda1): recovery complete [ 8.564389] EXT4-fs (sda1): mounted filesystem with ordered data mode. Opts: (null) [ 14.280922] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 14.280944] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 14.310368] udevd[308]: starting version 175 [ 14.353873] Adding 1045500k swap on /dev/sda5. Priority:-1 extents:1 across:1045500k [ 14.428718] lp: driver loaded but no devices found [ 14.521667] EXT4-fs (sda1): re-mounted. Opts: errors=remount-ro [ 15.073459] [drm] Initialized drm 1.1.0 20060810 [ 15.097073] psb_gfx: module is from the staging directory, the quality is unknown, you have been warned. [ 15.180630] gma500 0000:00:02.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 15.180648] gma500 0000:00:02.0: setting latency timer to 64 [ 15.182117] Stolen memory information [ 15.182127] base in RAM: 0x7f800000 [ 15.182134] size: 7932K, calculated by (GTT RAM base) - (Stolen base), seems wrong [ 15.182143] the correct size should be: 8M(dvmt mode=3) [ 15.234889] Set up 1983 stolen pages starting at 0x7f800000, GTT offset 0K [ 15.235126] [drm] SGX core id = 0x01130000 [ 15.235135] [drm] SGX core rev major = 0x01, minor = 0x02 [ 15.235143] [drm] SGX core rev maintenance = 0x01, designer = 0x00 [ 15.268796] [Firmware Bug]: ACPI: No _BQC method, cannot determine initial brightness [ 15.269888] acpi device:04: registered as cooling_device2 [ 15.270568] acpi device:05: registered as cooling_device3 [ 15.270947] input: Video Bus as /devices/LNXSYSTM:00/device:00/PNP0A08:00/LNXVIDEO:00/input/input5 [ 15.271238] ACPI: Video Device [GFX0] (multi-head: yes rom: no post: no) [ 15.271424] [drm] Supports vblank timestamp caching Rev 1 (10.10.2010). [ 15.271434] [drm] No driver support for vblank timestamp query. [ 15.374694] type=1400 audit(1349363644.167:2): apparmor="STATUS" operation="profile_load" name="/sbin/dhclient" pid=435 comm="apparmor_parser" [ 15.385518] type=1400 audit(1349363644.179:3): apparmor="STATUS" operation="profile_load" name="/usr/lib/NetworkManager/nm-dhcp-client.action" pid=435 comm="apparmor_parser" [ 15.386369] type=1400 audit(1349363644.179:4): apparmor="STATUS" operation="profile_load" name="/usr/lib/connman/scripts/dhclient-script" pid=435 comm="apparmor_parser" [ 15.677514] r8169 0000:01:00.0: eth0: link down [ 15.694828] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 16.537490] gma500 0000:00:02.0: allocated 800x480 fb [ 16.558066] fbcon: psbfb (fb0) is primary device [ 16.747122] gma500 0000:00:02.0: BL bug: Reg 00000000 save 00000000 [ 16.775550] Console: switching to colour frame buffer device 100x30 [ 16.781804] fb0: psbfb frame buffer device [ 16.781812] drm: registered panic notifier [ 16.870168] [drm] Initialized gma500 1.0.0 2011-06-06 for 0000:00:02.0 on minor 0 [ 16.871166] snd_hda_intel 0000:00:1b.0: power state changed by ACPI to D0 [ 16.871186] snd_hda_intel 0000:00:1b.0: power state changed by ACPI to D0 [ 16.871207] snd_hda_intel 0000:00:1b.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 16.871284] snd_hda_intel 0000:00:1b.0: setting latency timer to 64 [ 29.338953] r8169 0000:01:00.0: eth0: link up [ 29.339471] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 31.427223] init: failsafe main process (675) killed by TERM signal [ 31.522411] type=1400 audit(1349363660.316:5): apparmor="STATUS" operation="profile_replace" name="/sbin/dhclient" pid=889 comm="apparmor_parser" [ 31.523956] type=1400 audit(1349363660.316:6): apparmor="STATUS" operation="profile_replace" name="/usr/lib/NetworkManager/nm-dhcp-client.action" pid=889 comm="apparmor_parser" [ 31.524882] type=1400 audit(1349363660.320:7): apparmor="STATUS" operation="profile_replace" name="/usr/lib/connman/scripts/dhclient-script" pid=889 comm="apparmor_parser" [ 31.525940] type=1400 audit(1349363660.320:8): apparmor="STATUS" operation="profile_load" name="/usr/sbin/tcpdump" pid=891 comm="apparmor_parser" [ 34.526445] postgres (1003): /proc/1003/oom_adj is deprecated, please use /proc/1003/oom_score_adj instead. [ 40.144048] eth0: no IPv6 routers present

    Read the article

  • DPM 2010 "Disk failed or disk not found"

    - by SysAdmin
    I have an HP Proliant ML110 G5 server with Windows server 2008R2 only dedicated for DPM 2010. This server has a limit in HD of 8TB which has already been met. I'm now stuck in this situation where my disk keeps failing "Disk failed or Disk not found" in the disk management. Only after I reboot the system the disk comes back up. Today I was running my monthly tape backup on a certain protection group and the disk failed again while the tape job was running (so the job wasn't completed). This is the description of the error in the alerts: "The disk Disk 1 - Hitachi HDS722020ALA330 SCSI Disk Device cannot be detected or has stopped responding. All subsequent protection activities that use this disk will fail until the disk is brought back online. (ID 3120)". My backup system is becoming useless! I don't think that is a hardware issue (please correct me if I'm wrong) since the HD works fine for a certain period of time which is becoming shorter and shorter. I basically have no more option to fix this problem. I tried to fix any error that was coming up in the event viewer with no luck (included one regarding the SQL2008 compatibility issue). The disk keeps failing! Now I'm only trying to recover/migrate the data from the disk that is having problem but my issue now is that I cannot add any drives to my server since I already got installed the maximum storage capacity 8TB. I thought about 2 simple options. Please tell me what you guys think about it; Unplug one of the 2 storage pool disks (disk0, that one without problem) from the machine and install a new one in order to migrate the data with the Migration tool for DPM. Remove the defective disk (disk1), put back the disk0 and run the synchronization/consistency check on all the groups to recreate replicas and recovery points. Run diskpart.exe and clean up the disk (loosing all data) and hoping that he will work after I sync all the protection groups. Both solutions are not elegant but I have no better options at the moment. Please I need some help. Thanks for your time Angelo

    Read the article

  • EC2 Filesystem / Files stored on the wrong partiton after launching new instance from AMI

    - by Philip Isaacs
    Today I set up a new EC2 Instance from and AMI I created from an older EC2 instance. When I launched the new instance I took the AMI that was on a small instance and launched with a medium instance. From what I can tell this is pretty standard stuff. But here's the stang part. According to AWS these are the differences Small Instance (Default) 1.7 GB of memory, 1 EC2 Compute Unit (1 virtual core with 1 EC2 Compute Unit), 160 GB of local instance storage, 32-bit or 64-bit platform Medium Instance 3.75 GB of memory, 2 EC2 Compute Units (1 virtual core with 2 EC2 Compute Units each), 410 GB of local instance storage, 32-bit or 64-bit platform Okay now here's where I'm having an issue. I when I log into the new bigger instance it still reports only having 1.7 GB of ram. The other strange part is that all my old partitions are still their in the same configurations. I see a new larger partition /mnt which is essential empty. Filesystem Size Used Avail Use% Mounted on /dev/sda1 7.9G 5.9G 1.6G 79% / none 846M 120K 846M 1% /dev none 879M 0 879M 0% /dev/shm none 879M 76K 878M 1% /var/run none 879M 0 879M 0% /var/lock none 879M 0 879M 0% /lib/init/rw /dev/sda2 335G 195M 318G 1% /mnt /dev/sdf 16G 9.9G 5.1G 67% /var2 This EC2 is a web server and I was serving files off the /var2 directory but for some reason the instance is storing everything on / Okay here's what I'd like to do. Move all my website files to /mnt and have the web server point to that. Any suggestions? If it helps here is what my fstab looks like as well. root@myserver:/var# mount -l /dev/sda1 on / type ext3 (rw) [cloudimg-rootfs] proc on /proc type proc (rw,noexec,nosuid,nodev) none on /sys type sysfs (rw,noexec,nosuid,nodev) none on /sys/kernel/debug type debugfs (rw) none on /sys/kernel/security type securityfs (rw) none on /dev type devtmpfs (rw,mode=0755) none on /dev/pts type devpts (rw,noexec,nosuid,gid=5,mode=0620) none on /dev/shm type tmpfs (rw,nosuid,nodev) none on /var/run type tmpfs (rw,nosuid,mode=0755) none on /var/lock type tmpfs (rw,noexec,nosuid,nodev) none on /lib/init/rw type tmpfs (rw,nosuid,mode=0755) /dev/sda2 on /mnt type ext3 (rw) /dev/sdf on /var2 type ext4 (rw,noatime) I hope this question makes sense. Basically i want my old files on this new partition. Thanks in advance

    Read the article

  • Adaptec 5805 after reboot don't starting

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not included. It only works if the computer is shut down and turn off. Late i update firmware "Adaptec RAID 5805 Firmware Build 18948" How to fix the problem? add Log Configuration summary Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priorityHigh Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1 List item

    Read the article

  • SQL Server High Availability - Mirroring with MSCS?

    - by David
    I'm looking at options for high-availability for my SQL Server-powered application. The requirements are: HA protection from storage failure. Data accessibility when one of the DB servers is undergoing software updates (e.g. planned outage for Windows Update / SQL Server service-packs). Must not involve much in the way of hardware procurement. The application is an ASP.NET web application. The web application's users have their own database instances. I've seen two main options: SQL Server failover clustering, and SQL Server mirroring. I understand that SQL Server Failover Clustering requires the purchasing of a shared disk array and doesn't offer any protection if the shared storage goes down (so the documentation recommends to set up a Mirroring between two clusters). Database Mirroring seems the cheaper option (as it only requires two database servers and a simple witness box) - but I've heard it doesn't work well when you have a large number of databases. The application I'm developing involves giving each client their own database for their application - there could be hundreds of databases. Setting up the mirroring is no problem thanks to the automation systems we have in place. My final point concerns how failover works with respect to client connections - SQL Server Failover Clustering uses MSCS which means that the cluster is invisible to clients - a connection attempt might fail during the failover, but a simple reconnect will have it working again. However mirroring, as far as I know, requires that the client be aware of the mirrored partners: if the client cannot connect to the primary server then it tries the secondary server. I'm wondering how this work with respect to Connection Pooling in ASP.NET applications - does the client connection failovering mean that there's a potential 2-second (assuming 2000ms TCP timeout policy) pause when the connection pool tries the primary server on every connection attempt? I read somewhere that Mirroring can be used on top of MSCS which means that the client does not need to be aware of mirroring (so there wouldn't be any potential delays during connection, and also that no changes would need to be made to the client, not even the connection string) - however I'm finding it hard to get documentation or white papers on this approach. But if true, then it means the best method is then Mirroring (for HA) with MSCS (for client ignorance and connection performance). ...but how does this scale to a server instance that might contain hundreds of mirrored databases?

    Read the article

  • Bacula backup on Linux, restore on FreeBSD

    - by Martin Orda
    I'd like to migrate my storage server from Linux (Debian) to FreeBSD. Biggest part of this is restoring backups saved on Linux to tape volumes on the newly installed FreeBSD. Unfortunately I don't have anywhere to test this on at the moment but I'd like to ask you if you're aware of any incompatiblities or Bacula specific settings that should be used to make this as smooth of a process as possible.

    Read the article

  • Poor WAMP performance when using SMB/UNC Paths

    - by Brad
    I've configured a WAMP (Windows Apache MySQL and PHP) stack when when configured to use local storage takes 3-4 seconds to load. When I use an SMB/UNC share it takes 12-15 seconds to load. Here are the two lines in my httpd.conf: #DocumentRoot "//10.99.108.11/test_htdocs" #<Directory "//10.99.108.11/test_htdocs"> #DocumentRoot "C:/www" #<Directory "C:/www"> Is there performance tuning I can do on windows server 2008 R2 to improve performance or is there another way to improve performance using smb

    Read the article