Search Results

Search found 15646 results on 626 pages for 'port 80'.

Page 107/626 | < Previous Page | 103 104 105 106 107 108 109 110 111 112 113 114  | Next Page >

  • Switch Before Firewall / Router - Multiple public IPs

    - by rii
    I currently Have a 10Mbit Full duplex circuit connected to a small unmanaged switch which then connects to a Sonicwall Firewall / Router. I have several public IP addresses (/28) that are assigned to several devices in my setup. Now the problem is the small switch I have was lent to me and needs to be returned, I have replaced this switch with several other switches but for some reason any other switch I use causes the network to become extremely slow. I believe this is a problem with the autonegotiation of theses hubs, so I am thinking of purchasing a small managed switch (cisco 300 series) and making the receiving port on the swith Explicitly 10Mbit Full Duplex and see if this works. My question is, being that this is a managed switch and needs an IP, will I still be able to run my public ips through it? Say the circuit has 70.80.4.1 - 7 will I still be able to assign 70.80.4.2 to my firewall and 70.80.4.3 to my router connected to some other port in the switch? Will I have to assign the switch a public IP address in this range as well for it to "route" to those other devices or does the switch does not care what IPs goes through it while operating as a Layer 2 Switch? Any help would be greatly appreciated. Thanks in advanced!

    Read the article

  • use ssh tunnel with phpmyadmin

    - by JohnMerlino
    I been using ssh tunnel to bypass firewall of remote mysql server. On my Ubuntu 12.04 installation, it works via the terminal and it works when using a program called mysql workbench. However, that program freezes often and I want to try phpmyadmin as an alternative. However, I cannot connect to remote server using ssh tunnel on phpmyadmin, albeit I can connect locally. These are the steps I've tried: 1) Open a tunnel, listening on localhost:3307 and forwarding everything to xxx.xxx.xxx.xxx:3306 (used 3307 because MySQL on my local machine uses the default port 3306): ssh -L 3307:localhost:3306 [email protected] So now I have the port for tunnel open and I have my local mysql installation default port: $ netstat -tln Active Internet connections (only servers) Proto Recv-Q Send-Q Local Address Foreign Address State tcp 0 0 127.0.0.1:3306 0.0.0.0:* LISTEN tcp 0 0 127.0.0.1:3307 0.0.0.0:* LISTEN tcp 0 0 0.0.0.0:80 0.0.0.0:* LISTEN ... 2) Now I can easily connect to remote server via localhost using the terminal: $ mysql -u user.name -p -h 127.0.0.1 -P 3307 Notice that I expicitly identify 3307 as the port, so traffic forwards to the remote server, and hence it logs me in to the remote server. Unfortunately, the localhost/phpmyadmin local login interface doesn't allow you to specify a port option. So I modify the config-db.php file and change the $dbport variable to 3307, under the impression that the phpmyadmin interface will now work with port 3307: $ sudo vim /etc/phpmyadmin/config-db.php $dbport='3307'; Then I restart the mysql server. Unfortunately, it didn't work. When I use the remote credentials to login, it gives me error: #1045 Cannot log in to the MySQL server

    Read the article

  • Apache local verses external (domain)

    - by Jessy Houle
    I have an Apache server running on Ubuntu server 10, using Passenger for Ruby on Rails. I have configured my site under the sites-enabled directory of Apache and can hit the server with an internal IP address (192.168.X.X) and the site comes back as expected. However, whenever I try to hit the site externally, either through the domain name or the IP address tied to the domain name, the site will not come back. I have a router in the middle with a static IP address, with Port Forwarding turned on (forwarding 80/443) to the server and I'm quite confident the issue isn't there. In fact, I even DMZed to the Ubuntu Server just to make sure. Also, all router firewall options have been turned off. So here is the question... Is there something else I have to do with Ubuntu server to allow externally requested port 80 traffic? Otherwise, is there some settings that need to be set in Apache to allow domain or external IP address port 80 traffic through? I'm pretty new to Apache, so, please take it a bit easy on me :-) Thank you for your responses. -Jessy Houle

    Read the article

  • Share one ssl certificate between multiples vhost

    - by Cesar
    I have a setup like this: <VirtualHost 192.168.1.104:80> ServerName domain1 DocumentRoot /home/domain/public_html ... </VirtualHost> <VirtualHost 192.168.1.104:80> ServerName domain2 DocumentRoot /home/domain2/public_html ... </VirtualHost> <VirtualHost 192.168.1.104:80> DocumentRoot /home/domain3/public_html ServerName domain3 ... </VirtualHost> <VirtualHost 192.168.1.104:443> ServerName domain3 SSLCertificateFile /usr/share/ssl/certs/certificate.crt SSLCertificateKeyFile /usr/share/ssl/private/private.key SSLCACertificateFile /usr/share/ssl/certs/bundle.cabundle ... </VirtualHost> I want to use domain3 certificate in the other domains, preferably without having to repeat all the <VirtualHost 192.168.1.104:443> config. In other words I want something like this: If the vhost has no explicit ssl config use cert for domain3 (/usr/share/ssl/certs/certificate.crt) Notes: 1.- I for sure will be setting more vhosts in the future 2.- I know (and don't care) of the ssl warnings the browser will show (hostname mismatch) If this possible? how?

    Read the article

  • javascript doesn't seem to be able to post form data (nginx server w/ php-fpm)

    - by Jones
    So the situation is like so: I have a nginx server with php-fpm installed. All is well and the site scripts and all work perfectly. I am able to use html to POST form data and it works just fine. However, There seems to be be some correlation between javascript, the POST protocol and nothing happening. I cant seem to determine the issue. Example: I have a user login widget that uses javascript on submit the fields and POST the data to a backend auth script which returns a server message that then populates the login box saying something like "Login Successful" followed by reloading the page to properly enable content. Problem is, nothing happens when you hit submit. I do know the setup works because i had it working on apache before migrating. Also if it makes any difference, the server is a Amazon EC2 instance using the Amazon AMI. I really dont know where to start looking on this one, but below is my default.conf for the server: upstream backend_get { server 127.0.0.1:80 weight=1; } upstream backend_post { server 127.0.0.1:80 weight=1; } #Main website url server { listen 80; server_name server.com; #charset koi8-r; access_log logs/host.access.log main; error_log logs/host.error.log; location / { root /usr/share/nginx/html; index index.php index.html index.htm; if ($request_method = POST) { proxy_pass http://backend_post; break; } } location ~ \.php$ { #fastcgi_pass 127.0.0.1:9000; fastcgi_pass unix:/var/run/php-fpm/php-fpm.sock; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; include fastcgi_params; } }

    Read the article

  • How do I access my webserver on my stationary from my laptop?

    - by Steven
    I'm running Apache on my stationary and I would like to access a website through my laptop. This is some of the Apache config: NameVirtualHost 127.0.0.1:80 <VirtualHost 127.0.0.1:80> ServerName mysite.com DocumentRoot I:/wamp/www/mysite/ </VirtualHost> ServerName localhost:80 <Directory /> Options FollowSymLinks AllowOverride all Order deny,allow Deny from all </Directory> On my laptop I've added the following to the HOSTS file: 10.0.0.3 mysite.com But accessing the page through mysite.com is not very successfull. If I enter the IP address directly, I only get a Forbidden message. What do I need to do in order to get this to work? Update I'm runing WAMPSERVER 2.1 (Apache 2.2.17) Apache is up and running I can ping 10.0.0.3 from laptop I'm not able to ping http://mysite.com from laptop IE gives me a 403 Forbidden - The website declined to show this webpage The only log that get's entries when trying to access the website from my laptop, is access.log. access.log 10.0.0.4 - - [13/Jun/2011:10:14:04 +0200] "GET / HTTP/1.1" 403 202 apache_error.log [Mon Jun 13 10:08:16 2011] [error] VirtualHost localhost:0 -- mixing * ports and non-* ports with a NameVirtualHost address is not supported, proceeding with undefined results UPDATE 2 My apache config has the following entry: AllowOverride all Order Deny,Allow Deny from all Allow from 127.0.0.1 Could it be that this Allow from is stopping other computers accessing the page?

    Read the article

  • nginx doesn't find the directory but apache does

    - by Jack Spairow
    I use apache as the backend server and nginx on the frontend. Apache listens to port 8080 and nginx to port 80. What I do is have the root point to the public folder foreach virtualhost: <VirtualHost *:8080> ServerAdmin webmaster@localhost ServerName site.com ServerAlias site.com *.site.com DocumentRoot /var/www/site.com/public <Directory /> Options FollowSymLinks AllowOverride None </Directory> <Directory /var/www/site.com/public/> Options Indexes FollowSymLinks MultiViews AllowOverride All Order allow,deny allow from all </Directory> </VirtualHost> And here's the nginx config: server { listen 80; access_log /var/log/nginx.access.log; error_log /var/log/nginx.error.log; root /var/www/site.com/public; index index.php index.html; server_name site.com *.site.com; location / { location / { proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header Host $host; proxy_pass http://127.0.0.1:8080; proxy_cache one; proxy_cache_use_stale error timeout invalid_header updating; proxy_cache_key $scheme$host$request_uri; proxy_cache_valid 200 301 302 20m; proxy_cache_valid 404 1m; proxy_cache_valid any 15m; } } location ~ /\.(ht|git) { deny all; } } The problem is Apache resolves the domain just fine (site.com:8080), but nginx shows instead a 502 Bad Gateway (site.com:80). I tried looking at the error_log and access_log but I can't find any hint for why can't nginx work. EDIT: The problem was I wasn't able to include that isolated config for nginx.

    Read the article

  • Apache mod_proxy

    - by mhouston100
    Uggh, I'm spewing that I can't figure this out, I'm so frustrated: <VirtualHost *:80> servername domain1.com.au ServerAdmin webmaster@localhost DocumentRoot /var/www/html ErrorLog ${APACHE_LOG_DIR}/error.log CustomLog ${APACHE_LOG_DIR}/access.log combined <Proxy *> Order Allow,Deny Allow from all </Proxy> RewriteEngine on ReWriteCond %{SERVER_PORT} !^443$ RewriteRule ^/(.*) https://%{HTTP_HOST}/$1 [NC,R,L] </VirtualHost> <VirtualHost *:443> servername domain1.com.au SSLEngine on SSLCertificateFile /etc/apache2/ssl/owncloud.pem SSLCertificateKeyFile /etc/apache2/ssl/owncloud.key DocumentRoot /var/www/html </VirtualHost> <VirtualHost *:*> Servername domain2.com.au ProxyRequests Off <Proxy *> Order deny,allow Allow from all </Proxy> ProxyPass / https://192.168.1.12/ ProxyPassReverse / https://192.168.1.12/ </VirtualHost> Not sure if it's clear what I'm trying to do, but I've read and read and READ, I still can't figure it out. Basically I have a working Apache server with a rewrite to force HTTPS, as seen in the first two VirtualHost entries. I now have a webmail service I set up on another server, under another domain name, however I only have one incoming public IP address. So I'm trying to have any incoming requests for the second domain to be proxied to the other server to access the webmail, whether its port 80 or 443. IMAP and POP3 are no problems, I can just forward the ports directly to the correct server. The results of the above configuration is that requests to domain2.com.au (port 80 or 443) are forwarded to https://domain1.com.au. Am I headed in the right direction?

    Read the article

  • Separate Certificate by Subdomain (With multiple IPs)

    - by Brian
    Note: Yes, I realize this problem is easier to solve by just using 1 multi-domain or wildcard certificate. I wish to have an ASP.NET site running on IIS with 2 SSL domains sharing 1 web application but using separate certificates. Assuming I have 2 certificates, this can be solved on IIS7 as follows: Web Application1: Binding 1: http, 80, IP Address *, Host Name * Binding 2: https, 443, IPADDRESS1, using CERTDOMAIN1 (DOMAIN1 resolves to IPADDRESS1) Binding 3: https, 443, IPADDRESS2, using CERTDOMAIN2 (DOMAIN2 resolves to IPADDRESS2) That is to say, 2 certificates and 2 ip addresses, but both mapped to the same web application. In IIS6, the closest I have been able to come to this configuration is: Web Application1: Binding 1: http, 80, IPADDRESS1 Binding 2: https, 443, IPADDRESS1, using CERTDOMAIN1 (DOMAIN1 resolves to IPADDRESS1) Web Application2: Binding 1: http, 80, IPADDRESS2 Binding 2: https, 443, IPADDRESS2, using CERTDOMAIN2 (DOMAIN2 resolves to IPADDRESS2) That is to say, 2 certificates and 2 IP addresses, 2 web applications, both mapped to the same file location. The IIS6 solution is not optimal. Even if sharing an application pool, there are still costs associated with running the same site as two applications. Is upgrading from IIS6 to IIS7 a legitimate way to resolve this problem? Is there an IIS6 way to map 2 IP addresses within the same web application to different certificates?

    Read the article

  • Possible for linux bridge to intercept traffic?

    - by A G
    I have a linux machine setup as a bridge between a client and a server; brctl addbr0 brctl addif br0 eth1 brctl addif br0 eth2 ifconfig eth1 0.0.0.0 ifconfig eth2 0.0.0.0 ip link set br0 up I also have an application listening on port 8080 of this machine. Is it possible to have traffic destined for port 80 to be passed to my application? I have done some research and it looks like it could be done using ebtables and iptables. Here is the rest of my setup: //set the ebtables to pass this traffic up to ip for processing; DROP on the broute table should do this ebtables -t broute -A BROUTING -p ipv4 --ip-proto tcp --ip-dport 80 -j redirect --redirect-target DROP //set iptables to forward this traffic to my app listening on port 8080 iptables -t mangle -A PREROUTING -p tcp --dport 80 -j TPROXY --on-port 8080 --tproxy-mark 1/1 iptables -t mangle -A PREROUTING -p tcp -j MARK --set-mark 1/1 //once the flows are marked, have them delivered locally via loopback interface ip rule add fwmark 1/1 table 1 ip route add local 0.0.0.0/0 dev lo table 1 //enable ip packet forwarding echo 1 > /proc/sys/net/ipv4/ip_forward However nothing is coming into my application. Am I missing anything? My understanding is that the target DROP on the broute BROUTING chain will push it up to be processed by iptables. Secondly, are there any other alternatives I should investigate? Edit: IPtables gets it at nat PREROUTING, but it looks like it drops after that; the INPUT chain (in either mangle or filter) doesn't see the packet.

    Read the article

  • iptables rules to allow HTTP traffic to one domain only

    - by Zenet
    I need to configure my machine as to allow HTTP traffic to/from serverfault.com only. All other websites, services ports are not accessible. I came up with these iptables rules: #drop everything iptables -P INPUT DROP iptables -P OUTPUT DROP #Now, allow connection to website serverfault.com on port 80 iptables -A OUTPUT -p tcp -d serverfault.com --dport 80 -j ACCEPT iptables -A INPUT -m conntrack --ctstate ESTABLISHED,RELATED -j ACCEPT #allow loopback iptables -I INPUT 1 -i lo -j ACCEPT It doesn't work quite well: After I drop everything, and move on to rule 3: iptables -A OUTPUT -p tcp -d serverfault.com --dport 80 -j ACCEPT I get this error: iptables v1.4.4: host/network `serverfault.com' not found Try `iptables -h' or 'iptables --help' for more information. Do you think it is related to DNS? Should I allow it as well? Or should I just put IP addresses in the rules? Do you think what I'm trying to do could be achieved with simpler rules? How? I would appreciate any help or hints on this. Thanks a lot!

    Read the article

  • iptables rules for DNS/Transparent proxy with ip exceptions

    - by SlimSCSI
    I am running a router (A Netgear WNDR3700 if that matters) with dd-wrt. For content filtering I am using OpenDNS. I wanted to make sure a user could not bypass OpenDNS by putting in their own name servers, so I have a rule to catch all DNS traffic. iptables -t nat -A PREROUTING -i br0 -p all --dport 53 -j DNAT --to $LAN_IP I did have one computer on the network I wanted to allow past OpenDNS filters. On that machine I manually set the name servers, and created another rule to allow it to pass iptables -t nat -I PREROUTING -i br0 -s 192.168.1.2 -j ACCEPT This worked well. Today, I installed a transparent proxy (squid) on the router and added these rules: iptables -t nat -A PREROUTING -i br0 -s $LAN_NET -d $LAN_NET -p tcp --dport 80 -j ACCEPT iptables -t nat -A PREROUTING -i br0 -s ! $PROXY_IP -p tcp --dport 80 -j DNAT --to $PROXY_IP:$PROXY_PORT iptables -t nat -I POSTROUTING -o br0 -s $LAN_NET -d $PROXY_IP -p tcp -j SNAT --to $LAN_IP iptables -I FORWARD -i br0 -o br0 -s $LAN_NET -d $PROXY_IP -p tcp --dport $PROXY_PORT -j ACCEPT This also works, however the 192.168.1.2 address does not get routed through squid. How can I have 192.168.1.2 (and maybe others in the future) by-pass the port 53 rules, but not the port 80 rules?

    Read the article

  • amazon ec2-medium apache requests per second terrible

    - by TheDayIsDone
    EDITED -- test running from localhost now to rule out network... i have a c1.medium using EBS. when i do an apache benchmark and i'm just printing a "hello" for the test from localhost - no database hits, it's very slow. i can repeat this test many times with the same results. any thoughts? thanks in advance. ab -n 1000 -c 100 http://localhost/home/test/ Benchmarking localhost (be patient) Completed 100 requests Completed 200 requests Completed 300 requests Completed 400 requests Completed 500 requests Completed 600 requests Completed 700 requests Completed 800 requests Completed 900 requests Completed 1000 requests Finished 1000 requests Server Software: Apache/2.2.23 Server Hostname: localhost Server Port: 80 Document Path: /home/test/ Document Length: 5 bytes Concurrency Level: 100 Time taken for tests: 25.300 seconds Complete requests: 1000 Failed requests: 0 Write errors: 0 Total transferred: 816000 bytes HTML transferred: 5000 bytes Requests per second: 39.53 [#/sec] (mean) Time per request: 2530.037 [ms] (mean) Time per request: 25.300 [ms] (mean, across all concurrent requests) Transfer rate: 31.50 [Kbytes/sec] received Connection Times (ms) min mean[+/-sd] median max Connect: 0 7 21.0 0 73 Processing: 81 2489 665.7 2500 4057 Waiting: 80 2443 654.0 2445 4057 Total: 85 2496 653.5 2500 4057 Percentage of the requests served within a certain time (ms) 50% 2500 66% 2651 75% 2842 80% 2932 90% 3301 95% 3506 98% 3762 99% 3838 100% 4057 (longest request)

    Read the article

  • How should I configure my Apache Hosts File to serve a different site for localhost than for my domain/publicip?

    - by rofls
    I'm trying to test out a LAMP (with PHP5 specifically) setup with Django already serving a website. I want to do the PHP stuff on localhost for now, so that when I do something like this: curl http://localhost/database/script.php?var=1, I get a response from the php server. Right now I'm getting a Django error. I tried something like this in the default file in sites-available: Listen 80 <VirtualHost aaa.bbb.ccc.ddd> ServerName localhost DocumentRoot /home/phpsite </VirtualHost> where aaa.bbb.ccc.ddd is the local ip address, and changing my actual site's settings to specify the public ip, like this: Listen 80 <VirtualHost www.xxx.yyy.zzz> ServerName mysite.com DocumentRoot /srv/www/mysite WSGIScriptAlias / /srv/www/mysite.wsgi </VirtualHost> but then I start getting all kinds of errors when I start apache, such as port ::[80] is already in use or something. I noticed that the hosts file that's located in /etc/apache2/ is apparently pointing everything to mysite.com, including my local ip as well as 127.0.0.1 and 127.0.1.1; Do I need to change the configuration there too?

    Read the article

  • Nginx vhost configuration

    - by user101494
    I am attempting to setup a new server with Nginx 1.0.10 on debian 6. The config below works perfectly on a server with nginx 0.8.36 on Ubuntu 10.04.3 but not on the new box. The desired result is to: Redirect non-www request on the tld to www, but not not subdomains Use the the folder structure /var/www/[domain]/htdocs /var/www/[domain]/subdomains/[subdomain]/htdocs Serve files any host for which files exist in this structure On the new server domains are matching correctly but subdomains are matching to /var/www/[subdomain].[domain]/htdocs not /var/www/[domain]/subdomains/[subdomain]/htdocs server { listen 80; server_name _________ ~^[^.]+\.[^.]+$; rewrite ^(.*)$ $scheme://www.$host$1 permanent; } server { listen 80; server_name _ ~^www\.(?<domain>.+)$; server_name_in_redirect off; location / { root /var/www/$domain/htdocs; index index.html index.htm index.php; fastcgi_index index.php; } location ~ \.php$ { include /etc/nginx/fastcgi_params; keepalive_timeout 0; fastcgi_pass 127.0.0.1:9000; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; } location ~ /\.ht { deny all; } } server { listen 80; server_name __ ~^(?<subdomain>\.)?(?<domain>.+)$$; server_name_in_redirect off; location / { root /var/www/$domain/subdomains/$subdomain/htdocs; index index.html index.htm index.php; fastcgi_index index.php; } location ~ \.php$ { include /etc/nginx/fastcgi_params; keepalive_timeout 0; fastcgi_pass 127.0.0.1:9000; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; } location ~ /\.ht { deny all; } }

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Right-margin marks in VS2010 text editors

    - by nc97217
    In VS2008, you could enable right-margin marks by creating a string registry entry named Guides under HKCU\Software\Microsoft\VisualStudio\9.0\Text Editor. It also worked with the express editions: replace VisualStudio with VCExpress or VCSExpress. The value I had was: RGB(192,192,192) 80, 100 which gave me light gray lines at columns 80 and 100. I've just tried (and failed) to set them up in VC++2010 Express and VC#2010 Express; does anyone know if they're still supported?

    Read the article

  • password problem with git clone gitosis@host:gitosis-admin.git

    - by rama
    Hi, all I'm confronted with some problems when trying to configure gitosis on Ubuntu. When i run this command git clone gitosis@host:gitosis-admin.git For my local machine i used git clone git@59.80.70.68:gitosis-admin.git where 59.80.70.68 is the ip of the server. But I get a password problem. I tried entering password of the server machine, but it fails Kindly help me.

    Read the article

  • Can't detect wireless networks, running ubuntu 9.10 on eeepc 1000he

    - by David Brown
    Hi, I am running Ubuntu 9.10 on an ASUS eeepc 1000HE, and my wireless card, RaLink RT 2860, is failing to recognize any wireless networks. It was working fine this morning, until I accidentally hit Fn F2, disabling the wireless card. I hit Fn F2 again to reenable it, but it no longer will detect any wireless networks (and other computers in the household do recognize them). Any help at all will be greatly appreciated! I googled quite a bit and talked to a human about this but could not fix it. We tried dhclient ra0, which returned There is already a pid file /var/run/dhclient.pid with pid 2438 killed old client process, removed PID file Internet Systems Consortium DHCP Client V3.1.2 Copyright 2004-2008 Internet Systems Consortium. All rights reserved. For info, please visit http://www.isc.org/sw/dhcp/ Listening on LPF/ra0/00:25:d3:13:f4:20 Sending on LPF/ra0/00:25:d3:13:f4:20 Sending on Socket/fallback DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 6 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 9 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 12 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 8 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 10 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 10 DHCPDISCOVER on ra0 to 255.255.255.255 port 67 interval 6 No DHCPOFFERS received. No working leases in persistent database - sleeping. Other data: iwconfig returns (other stuff here...) ra0 RT2860 Wireless ESSID:"" Nickname:"RT2860STA" Mode:Auto Frequency=2.412 GHz Bit Rate=1 Mb/s RTS thr:off Fragment thr:off Link Quality=10/100 Signal level:0 dBm Noise level:-87 dBm Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:0 Invalid misc:0 Missed beacon:0 ifconfig returns (other stuff here...) ra0 Link encap:Ethernet HWaddr 00:25:d3:13:f4:20 inet6 addr: fe80::225:d3ff:fe13:f420/64 Scope:Link UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:583 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) Interrupt:19 ra0:avahi Link encap:Ethernet HWaddr 00:25:d3:13:f4:20 inet addr:169.254.7.117 Bcast:169.254.255.255 Mask:255.255.0.0 UP BROADCAST MULTICAST MTU:1500 Metric:1 Interrupt:19

    Read the article

  • JBOSS 7.1 started hanging after 6 months of deployment

    - by PVR
    My application is been live from 6 months. The application is host on jboss 7.1 server. From last few days I am finding numerous problem of hanging of jboss server. Though I restart the jboss server again, it does not invoke. I need to restart the server machine itself. Can anyone please let me know what could be the cause of these problems and the workable resolutions or any suggestion ? Kindly dont degrade the question as I am facing a lot problems due to this hanging issue. Also for the information, the application is based on Java, GWT, Hibernate 3. Please find the standalone.xml file in case if it helps. <extensions> <extension module="org.jboss.as.clustering.infinispan"/> <extension module="org.jboss.as.configadmin"/> <extension module="org.jboss.as.connector"/> <extension module="org.jboss.as.deployment-scanner"/> <extension module="org.jboss.as.ee"/> <extension module="org.jboss.as.ejb3"/> <extension module="org.jboss.as.jaxrs"/> <extension module="org.jboss.as.jdr"/> <extension module="org.jboss.as.jmx"/> <extension module="org.jboss.as.jpa"/> <extension module="org.jboss.as.logging"/> <extension module="org.jboss.as.mail"/> <extension module="org.jboss.as.naming"/> <extension module="org.jboss.as.osgi"/> <extension module="org.jboss.as.pojo"/> <extension module="org.jboss.as.remoting"/> <extension module="org.jboss.as.sar"/> <extension module="org.jboss.as.security"/> <extension module="org.jboss.as.threads"/> <extension module="org.jboss.as.transactions"/> <extension module="org.jboss.as.web"/> <extension module="org.jboss.as.webservices"/> <extension module="org.jboss.as.weld"/> </extensions> <system-properties> <property name="org.apache.coyote.http11.Http11Protocol.COMPRESSION" value="on"/> <property name="org.apache.coyote.http11.Http11Protocol.COMPRESSION_MIME_TYPES" value="text/javascript,text/css,text/html,text/xml,text/json"/> </system-properties> <management> <security-realms> <security-realm name="ManagementRealm"> <authentication> <properties path="mgmt-users.properties" relative-to="jboss.server.config.dir"/> </authentication> </security-realm> <security-realm name="ApplicationRealm"> <authentication> <properties path="application-users.properties" relative-to="jboss.server.config.dir"/> </authentication> </security-realm> </security-realms> <management-interfaces> <native-interface security-realm="ManagementRealm"> <socket-binding native="management-native"/> </native-interface> <http-interface security-realm="ManagementRealm"> <socket-binding http="management-http"/> </http-interface> </management-interfaces> </management> <profile> <subsystem xmlns="urn:jboss:domain:logging:1.1"> <console-handler name="CONSOLE"> <level name="INFO"/> <formatter> <pattern-formatter pattern="%d{HH:mm:ss,SSS} %-5p [%c] (%t) %s%E%n"/> </formatter> </console-handler> <periodic-rotating-file-handler name="FILE"> <formatter> <pattern-formatter pattern="%d{HH:mm:ss,SSS} %-5p [%c] (%t) %s%E%n"/> </formatter> <file relative-to="jboss.server.log.dir" path="server.log"/> <suffix value=".yyyy-MM-dd"/> <append value="true"/> </periodic-rotating-file-handler> <logger category="com.arjuna"> <level name="WARN"/> </logger> <logger category="org.apache.tomcat.util.modeler"> <level name="WARN"/> </logger> <logger category="sun.rmi"> <level name="WARN"/> </logger> <logger category="jacorb"> <level name="WARN"/> </logger> <logger category="jacorb.config"> <level name="ERROR"/> </logger> <root-logger> <level name="INFO"/> <handlers> <handler name="CONSOLE"/> <handler name="FILE"/> </handlers> </root-logger> </subsystem> <subsystem xmlns="urn:jboss:domain:configadmin:1.0"/> <subsystem xmlns="urn:jboss:domain:datasources:1.0"> <datasources> <datasource jndi-name="java:jboss/datasources/ExampleDS" pool-name="ExampleDS" enabled="true" use-java-context="true"> <connection-url>jdbc:h2:mem:test;DB_CLOSE_DELAY=-1</connection-url> <driver>h2</driver> <security> <user-name>sa</user-name> <password>sa</password> </security> </datasource> <drivers> <driver name="h2" module="com.h2database.h2"> <xa-datasource-class>org.h2.jdbcx.JdbcDataSource</xa-datasource-class> </driver> </drivers> </datasources> </subsystem> <subsystem xmlns="urn:jboss:domain:deployment-scanner:1.1"> <deployment-scanner path="deployments" relative-to="jboss.server.base.dir" scan-interval="5000"/> </subsystem> <subsystem xmlns="urn:jboss:domain:ee:1.0"/> <subsystem xmlns="urn:jboss:domain:ejb3:1.2"> <session-bean> <stateless> <bean-instance-pool-ref pool-name="slsb-strict-max-pool"/> </stateless> <stateful default-access-timeout="5000" cache-ref="simple"/> <singleton default-access-timeout="5000"/> </session-bean> <pools> <bean-instance-pools> <strict-max-pool name="slsb-strict-max-pool" max-pool-size="20" instance-acquisition-timeout="5" instance-acquisition-timeout-unit="MINUTES"/> <strict-max-pool name="mdb-strict-max-pool" max-pool-size="20" instance-acquisition-timeout="5" instance-acquisition-timeout-unit="MINUTES"/> </bean-instance-pools> </pools> <caches> <cache name="simple" aliases="NoPassivationCache"/> <cache name="passivating" passivation-store-ref="file" aliases="SimpleStatefulCache"/> </caches> <passivation-stores> <file-passivation-store name="file"/> </passivation-stores> <async thread-pool-name="default"/> <timer-service thread-pool-name="default"> <data-store path="timer-service-data" relative-to="jboss.server.data.dir"/> </timer-service> <remote connector-ref="remoting-connector" thread-pool-name="default"/> <thread-pools> <thread-pool name="default"> <max-threads count="10"/> <keepalive-time time="100" unit="milliseconds"/> </thread-pool> </thread-pools> </subsystem> <subsystem xmlns="urn:jboss:domain:infinispan:1.2" default-cache-container="hibernate"> <cache-container name="hibernate" default-cache="local-query"> <local-cache name="entity"> <transaction mode="NON_XA"/> <eviction strategy="LRU" max-entries="10000"/> <expiration max-idle="100000"/> </local-cache> <local-cache name="local-query"> <transaction mode="NONE"/> <eviction strategy="LRU" max-entries="10000"/> <expiration max-idle="100000"/> </local-cache> <local-cache name="timestamps"> <transaction mode="NONE"/> <eviction strategy="NONE"/> </local-cache> </cache-container> </subsystem> <subsystem xmlns="urn:jboss:domain:jaxrs:1.0"/> <subsystem xmlns="urn:jboss:domain:jca:1.1"> <archive-validation enabled="true" fail-on-error="true" fail-on-warn="false"/> <bean-validation enabled="true"/> <default-workmanager> <short-running-threads> <core-threads count="50"/> <queue-length count="50"/> <max-threads count="50"/> <keepalive-time time="10" unit="seconds"/> </short-running-threads> <long-running-threads> <core-threads count="50"/> <queue-length count="50"/> <max-threads count="50"/> <keepalive-time time="100" unit="seconds"/> </long-running-threads> </default-workmanager> <cached-connection-manager/> </subsystem> <subsystem xmlns="urn:jboss:domain:jdr:1.0"/> <subsystem xmlns="urn:jboss:domain:jmx:1.1"> <show-model value="true"/> <remoting-connector/> </subsystem> <subsystem xmlns="urn:jboss:domain:jpa:1.0"> <jpa default-datasource=""/> </subsystem> <subsystem xmlns="urn:jboss:domain:mail:1.0"> <mail-session jndi-name="java:jboss/mail/Default"> <smtp-server outbound-socket-binding-ref="mail-smtp"/> </mail-session> </subsystem> <subsystem xmlns="urn:jboss:domain:naming:1.1"/> <subsystem xmlns="urn:jboss:domain:osgi:1.2" activation="lazy"> <properties> <property name="org.osgi.framework.startlevel.beginning"> 1 </property> </properties> <capabilities> <capability name="javax.servlet.api:v25"/> <capability name="javax.transaction.api"/> <capability name="org.apache.felix.log" startlevel="1"/> <capability name="org.jboss.osgi.logging" startlevel="1"/> <capability name="org.apache.felix.configadmin" startlevel="1"/> <capability name="org.jboss.as.osgi.configadmin" startlevel="1"/> </capabilities> </subsystem> <subsystem xmlns="urn:jboss:domain:pojo:1.0"/> <subsystem xmlns="urn:jboss:domain:remoting:1.1"> <connector name="remoting-connector" socket-binding="remoting" security-realm="ApplicationRealm"/> </subsystem> <subsystem xmlns="urn:jboss:domain:resource-adapters:1.0"/> <subsystem xmlns="urn:jboss:domain:sar:1.0"/> <subsystem xmlns="urn:jboss:domain:security:1.1"> <security-domains> <security-domain name="other" cache-type="default"> <authentication> <login-module code="Remoting" flag="optional"> <module-option name="password-stacking" value="useFirstPass"/> </login-module> <login-module code="RealmUsersRoles" flag="required"> <module-option name="usersProperties" value="${jboss.server.config.dir}/application-users.properties"/> <module-option name="rolesProperties" value="${jboss.server.config.dir}/application-roles.properties"/> <module-option name="realm" value="ApplicationRealm"/> <module-option name="password-stacking" value="useFirstPass"/> </login-module> </authentication> </security-domain> <security-domain name="jboss-web-policy" cache-type="default"> <authorization> <policy-module code="Delegating" flag="required"/> </authorization> </security-domain> <security-domain name="jboss-ejb-policy" cache-type="default"> <authorization> <policy-module code="Delegating" flag="required"/> </authorization> </security-domain> </security-domains> </subsystem> <subsystem xmlns="urn:jboss:domain:threads:1.1"/> <subsystem xmlns="urn:jboss:domain:transactions:1.1"> <core-environment> <process-id> <uuid/> </process-id> </core-environment> <recovery-environment socket-binding="txn-recovery-environment" status-socket-binding="txn-status-manager"/> <coordinator-environment default-timeout="300"/> </subsystem> <subsystem xmlns="urn:jboss:domain:web:1.1" default-virtual-server="default-host" native="false"> <connector name="http" protocol="HTTP/1.1" scheme="http" socket-binding="http"/> <virtual-server name="default-host" enable-welcome-root="false"> <alias name="localhost"/> <alias name="nextenders.com"/> </virtual-server> </subsystem> <subsystem xmlns="urn:jboss:domain:webservices:1.1"> <modify-wsdl-address>true</modify-wsdl-address> <wsdl-host>${jboss.bind.address:127.0.0.1}</wsdl-host> <endpoint-config name="Standard-Endpoint-Config"/> <endpoint-config name="Recording-Endpoint-Config"> <pre-handler-chain name="recording-handlers" protocol-bindings="##SOAP11_HTTP ##SOAP11_HTTP_MTOM ##SOAP12_HTTP ##SOAP12_HTTP_MTOM"> <handler name="RecordingHandler" class="org.jboss.ws.common.invocation.RecordingServerHandler"/> </pre-handler-chain> </endpoint-config> </subsystem> <subsystem xmlns="urn:jboss:domain:weld:1.0"/> </profile> <interfaces> <interface name="management"> <inet-address value="${jboss.bind.address.management:127.0.0.1}"/> </interface> <interface name="public"> <inet-address value="${jboss.bind.address:127.0.0.1}"/> </interface> <interface name="unsecure"> <inet-address value="${jboss.bind.address.unsecure:127.0.0.1}"/> </interface> </interfaces> <socket-binding-group name="standard-sockets" default-interface="public" port-offset="${jboss.socket.binding.port-offset:0}"> <socket-binding name="management-native" interface="management" port="${jboss.management.native.port:9999}"/> <socket-binding name="management-http" interface="management" port="${jboss.management.http.port:9990}"/> <socket-binding name="management-https" interface="management" port="${jboss.management.https.port:9443}"/> <socket-binding name="ajp" port="8009"/> <socket-binding name="http" port="80"/> <socket-binding name="https" port="443"/> <socket-binding name="osgi-http" interface="management" port="8090"/> <socket-binding name="remoting" port="4447"/> <socket-binding name="txn-recovery-environment" port="4712"/> <socket-binding name="txn-status-manager" port="4713"/> <outbound-socket-binding name="mail-smtp"> <remote-destination host="localhost" port="25"/> </outbound-socket-binding> </socket-binding-group>

    Read the article

  • How to Read Device Data From COM

    - by Aamir Khurshid
    I have one device which sends data on COM port say on COM13, now i want to read that data and display it in the RichtextBox or in any text control , i have written the application with the help of IO and IO.Ports but comport.DataRecived event does not fire,even though device is sending data on that port, I have some software on which i define the port number and it successfully display data ,which insure me that data is reciving on the Port but i am unable to recive, is there any way i can read data? Regards, Aamir

    Read the article

  • Forward all traffic through an ssh tunnel

    - by Eamorr
    I hope someone can follow this and I'll explain as best I can. I'm trying to forward all traffic from port 6999 on x.x.x.224, through an ssh tunnel, and onto port 7000 on x.x.x.218. Here is some ASCII art: |browser|-----|Squid on x.x.x.224|------|ssh tunnel|------<satellite link>-----|Squid on x.x.x.218|-----|www| 3128 6999 7000 80 When I remove the ssh tunnel, everything works fine. The idea is to turn off encryption on the ssh tunnel (to save bandwidth) and turn on maximum compression (to save more bandwidth). This is because it's a satellite link. Here's the ssh tunnel I've been using: ssh -C -f -C -o CompressionLevel=9 -o Cipher=none [email protected] -L 7000:172.16.1.224:6999 -N The trouble is, I don't know how to get data from Squid on x.x.x.224 into the ssh tunnel? Am I going about this the wrong way? Should I create an ssh tunnel on x.x.x.218? I use iptables to stop squid on x.x.x.224 from reading port 80, but to feed from port 6999 instead (i.e. via the ssh tunnel). Do I need another iptables rule? Any comments greatly appreciated. Many thanks in advance, Regarding Eduardo Ivanec's question, here is a netstat -i any port 7000 -nn dump from x.x.x.218: 14:42:15.386462 IP 172.16.1.224.40006 > 172.16.1.218.7000: Flags [S], seq 2804513708, win 14600, options [mss 1460,sackOK,TS val 86702647 ecr 0,nop,wscale 4], length 0 14:42:15.386690 IP 172.16.1.218.7000 > 172.16.1.224.40006: Flags [R.], seq 0, ack 2804513709, win 0, length 0 Update 2: When I run the second command, I get the following error in my browser: ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://109.123.109.205/index.php Zero Sized Reply Squid did not receive any data for this request. Your cache administrator is webmaster. Generated Fri, 01 Jul 2011 16:06:06 GMT by remote-site (squid/2.7.STABLE9) remote-site is 172.16.1.224 When I do a tcpdump -i any port 7000 -nn I get the following: root@remote-site:~# tcpdump -i any port 7000 -nn tcpdump: verbose output suppressed, use -v or -vv for full protocol decode listening on any, link-type LINUX_SLL (Linux cooked), capture size 65535 bytes channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused

    Read the article

  • Centering a percent-based div

    - by Sarfraz
    Hello, Recently, a client asked that his site be percent-based rather than pixel-based. The percent was to be set to 80%. As you guys know, it is very easy to center the container if it is pixel-based but how do you center a percent-based main container? #container { width:80%; margin:0px auto; } That does not center the container :(

    Read the article

  • Do you still limit line length in code?

    - by Noldorin
    This is a matter on which I would like to gauge the opinion of the community: Do you still limit the length of lines of code to a fixed maximum? This was certainly a convention of the past for many languages; one would typically cap the number of characters per line to a value such as 80 (and more recnetly 100 or 120 I believe). As far as I understand, the primary reasons for limiting line length are: Readability - You don't have to scroll over horizontally when you want to see the end of some lines. Printing - Admittedly (at least in my experience), most code that you are working on does not get printed out on paper, but by limiting the number of characters you can insure that formatting doesn't get messed up when printed. Past editors (?) - Not sure about this one, but I suspect that at some point in the distant past of programming, (at least some) text editors may have been based on a fixed-width buffer. I'm sure there are points that I am still missing out, so feel free to add to these... Now, when I tend to observe C or C# code nowadays, I often see a number of different styles, the main ones being: Line length capped to 80, 100, or even 120 characters. As far as I understand, 80 is the traditional length, but the longer ones of 100 and 120 have appeared because of the widespread use of high resolutions and widescreen monitors nowadays. No line length capping at all. This tends to be pretty horrible to read, and I don't see it too often, though it's certainly not too rare either. Inconsistent capping of line length. The length of some lines are limited to a fixed maximum (or even a maximum that changes depending on the file/location in code), while others (possibly comments) are not at all. My personal preference here (at least recently) has been to cap the line length to 100 in the Visual Studio editor. This means that in a decently sized window (on a non-widescreen monitor), the ends of lines are still fully visible. I can however see a few disadvantages in this, especially when you end up writing code that's indented 3 or 4 levels and then having to include a long string literal - though I often take this as a sign to refactor my code! In particular, I am curious what the C and C# coders (or anyone who uses Visual Studio for that matter) think about this point, though I would be interested in hearing anyone's thoughts on the subject. Edit Thanks for the all answers - I appreciate the variety of opinions here, all presenting sound reasons. Consensus does seem to be tipping in the direction of always (or almost always) limit the line length. Interestingly, it seems to be in various coding standards to limit the line length. Judging by some of the answers, both the Python and Google CPP guidelines set the limit at 80 chars. I haven't seen anything similar regarding C# or VB.NET, but I would be curious to see if there are ones anywhere.

    Read the article

< Previous Page | 103 104 105 106 107 108 109 110 111 112 113 114  | Next Page >