Search Results

Search found 24353 results on 975 pages for 'test coverage'.

Page 107/975 | < Previous Page | 103 104 105 106 107 108 109 110 111 112 113 114  | Next Page >

  • setting documentroot in apache

    - by fusion
    i've set the documentroot in httpd.conf as: DocumentRoot "C:\Users\user1\Documents\WebProjects" if the files are located in WebProjects, they work; however if i create a sub folder [project] in WebProjects and access them via the browser, it doesn't load. for example, if i create a folder 'test' in WebProjects and a php file called test.php and call it: localhost/test/test.php . .this won't work and give the error of file not found on server. but if i put all the files in WebProjects itself, ie. test.php in WebProjects, it will work [localhost/test.php]. this makes my WebProjects folder look very cluttered with different files of different projects strewn around. and it isn't practical either. i'm new to using apache and hence would like to know how to set the document root such that i can access and load all the Projects/folders in WebProjects.

    Read the article

  • TFS 2010 Build: Dealing with the API restriction error

    - by Jakob Ehn
    Recently I’ve come across this error a couple of times when running builds that exeucte unit tests using Test containers: API restriction: The assembly 'file:///C:\Builds\<path>\myassembly.dll' has already loaded from a different location. It cannot be loaded from a new location within the same appdomain. Every time I’ve got this error, the project has been a web application, and the path to the assembly points down to the _PublishedWebsites directory that is created beneath the Binaries folder during a team build. The error description really says it all (although slightly cryptic), when using test containers, MSTest needs to load all assemblies and see if they contain any unit tests. During this serach, it finds the ‘myassembly.dll’ in two different locations. First it is found directly beneth the Binaries folder, and then it is alos found beneath the _PublishedWebsites\Project\bin folder. The reason is that the default setting for test containers in a TFS 2010 build definition is **\*test*.dll:   This pattern means that MSTest will search recursively for all assemblies beneath the Binaries folder, and during the search it will find the MyAssembly.dll twice. The solution is simple, set the Test assembly file specification property to *test*.dll instead, this will disable the recursive search:

    Read the article

  • Oracle 64-bit assembly throws BadImageFormatException when running unit tests

    - by pjohnson
    We recently upgraded to the 64-bit Oracle client. Since then, Visual Studio 2010 unit tests that hit the database (I know, unit tests shouldn't hit the database--they're not perfect) all fail with this error message:Test method MyProject.Test.SomeTest threw exception: System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation. ---> System.BadImageFormatException: Could not load file or assembly 'Oracle.DataAccess, Version=4.112.3.0, Culture=neutral, PublicKeyToken=89b483f429c47342' or one of its dependencies. An attempt was made to load a program with an incorrect format.I resolved this by changing the test settings to run tests in 64-bit. From the Test menu, go to Edit Test Settings, and pick your settings file. Go to Hosts, and change the "Run tests in 32 bit or 64 bit process" dropdown to "Run tests in 64 bit process on 64 bit machine". Now your tests should run.This fix makes me a little nervous. Visual Studio 2010 and earlier seem to change that file for no apparent reason, add more settings files, etc. If you're not paying attention, you could have TestSettings1.testsettings through TestSettings99.testsettings sitting there and never notice the difference. So it's worth making a note of how to change it in case you have to redo it, and being vigilant about files VS tries to add.I'm not entirely clear on why this was even a problem. Isn't that the point of an MSIL assembly, that it's not specific to the hardware it runs on? An IL disassembler can open the Oracle.DataAccess.dll in question, and in its Runtime property, I see the value "v4.0.30319 / x64". So I guess the assembly was specifically build to target 64-bit platforms only, possibly due to a 64-bit-specific difference in the external Oracle client upon which it depends. Most other assemblies, especially in the .NET Framework, list "msil", and a couple list "x86". So I guess this is another entry in the long list of ways Oracle refuses to play nice with Windows and .NET.If this doesn't solve your problem, you can read others' research into this error, and where to change the same test setting in Visual Studio 2012.

    Read the article

  • avconv and ffmpeg - drawtext filter text_w evaluates as 0 in Ubuntu Precise

    - by Chris White
    I'm attempting to draw text onto a video using either the avconv or ffmpeg commands. When specifying x= for where on the final video to place the text, the 'text_w' value is evaluating to 0, rather than the width of the rendered text as it should. I'm using Ubuntu 12.04 I've got avconv version 0.8.3-4:0.8.3-0ubuntu0.12.04.1 and ffmpeg version 0.8.3-4:0.8.3-0ubuntu0.12.04.1 Example command: avconv -i test.mov -vf "drawtext=fontfile='/usr/share/fonts/truetype/ttf-dejavu/DejaVuSans.ttf':text='test text':x=text_w:y=50:fontsize=24:fontcolor=black" texted.mov This command causes the text to be printed as if x were set to 0. What I'd really like to be able to do is center the text horizontally using something like this: avconv -i test.mov -vf "drawtext=fontfile='/usr/share/fonts/truetype/ttf-dejavu/DejaVuSans.ttf':text='test text':x=(main_w-text_w)/2:y=50:fontsize=24:fontcolor=black" texted.mov Using ffmpeg for to attempt the same ends with the same result ffmpeg -i test.mov -vf "drawtext=fontfile='/usr/share/fonts/truetype/ttf-dejavu/DejaVuSans.ttf':text='test text':x=(main_w-text_w)/2:y=50:fontsize=24:fontcolor=black" texted.mov

    Read the article

  • Collaboration using github and testing the code

    - by wyred
    The procedure in my team is that we all commit our code to the same development branch. We have a test server that runs updated code from this branch so that we can test our code on the servers. The problem is that if we want to merge the development branch to the master branch in order to publish new features to our production servers, some features that may not have been ready will be applied to the production servers. So we're considering having each developer work on a feature/topic branch where each of them work on their own features and when it's ready, merge it into the development branch for testing, and then into the master branch. However, because our test server only pulls changes from the development branch, the developers are unable to test their features. While this is not a huge issue as they can test it on their local machine, the only problem I foresee is if we want to test callbacks from third-party services like sendgrid (where you specify a url for sendgrid to update you on the status of emails sent out). How to handle this problem? Note: We're not advanced git users. We use the Github app for MacOSX and Windows to commit our work.

    Read the article

  • Oracle Enterprise Manager 12c Configuration Best Practices (Part 3 of 3)

    - by Bethany Lapaglia
    <span id="XinhaEditingPostion"></span>&amp;lt;span id=&amp;quot;XinhaEditingPostion&amp;quot;&amp;gt;&amp;lt;/span&amp;gt;&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt;span id=&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot;XinhaEditingPostion&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;quot;&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;gt;&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt;/span&amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;gt; This is part 3 of a three-part blog series that summarizes the most commonly implemented configuration changes to improve performance and operation of a large Enterprise Manager 12c environment. A “large” environment is categorized by the number of agents, targets and users. See the Oracle Enterprise Manager Cloud Control Advanced Installation and Configuration Guide chapter on Sizing for more details on sizing your environment properly. Part 1 of this series covered recommended configuration changes for the OMS and Repository Part 2 covered recommended changes for the Weblogic server Part 3 covers general configuration recommendations and a few known issues The entire series can be found in the My Oracle Support note titled Oracle Enterprise Manager 12c Configuration Best Practices [1553342.1]. Configuration Recommendations Configure E-Mail Notifications for EM related Alerts In some environments, the notifications for events for different target types may be sent to different support teams (i.e. notifications on host targets may be sent to a platform support team). However, the EM application administrators should be well informed of any alerts or problems seen on the EM infrastructure components. Recommendation: Create a new Incident rule for monitoring all EM components and setup the notifications to be sent to the EM administrator(s). The notification methods available can create or update an incident, send an email or forward to an event connector. To setup the incident rule set follow the steps below. Note that each individual rule in the rule set can have different actions configured. 1.  To create an incident rule for monitoring the EM components, click on Setup / Incidents / Incident Rules. On the All Enterprise Rules page, click on the out-of-box rule called “Incident management Ruleset for all targets” and then click on the Actions drop down list and select “Create Like Rule Set…” 2. For the rule set name, enter a name such as MTM Ruleset. Under the Targets tab, select “All targets of types” and select “OMS and Repository” from the drop down list. This target type contains all of the key EM components (OMS servers, repository, domains, etc.) 3. Click on the Rules tab. To edit a rule, click on the rule name and click on Edit as seen below 4. Modify the following rules: a. Incident creation Rule for metric alerts i. Leave the Type set as is but change the Severity to add Warning by clicking on the drop down list and selecting “Warning”. Click Next. ii.  Add or modify the actions as required (i.e. add email notifications). Click Continue and then click Next. iii. Leave the Name and description the same and click Next. iv. Click Continue on the Review page. b. Incident creation Rule for target unreachable. i.   Leave the Type set as is but change the Target type to add OMS and Repository by clicking on the drop down list selecting “OMS and Repository”. Click Next. ii.  Add or modify the actions as required (i.e. add email notifications) Click Continue and then click Next. iii. Leave the Name and description the same and click Next. iv. Click Continue on the Review page. 5.  Modify the actions for any other rule as required and be sure to click the “Save” push button to save the rule set or all changes will be lost. Configure Out-of-Band Notifications for EM Agent Out-of-Band notifications act as a backup when there’s a complete EM outage or a repository database issue. This is configured on the agent of the OMS server and can be used to send emails or execute another script that would create a trouble ticket. It will send notifications about the following issues: • Repository Database down • All OMS are down • Repository side collection job that is broken or has an invalid schedule • Notification job that is broken or has an invalid schedule Recommendation: To setup Out-of-Band Notifications, refer to the MOS note “How To Setup Out Of Bound Email Notification In 12c” (Doc ID 1472854.1) Modify the Performance Test for the EM Console Service The EM Console Service has an out-of-box defined performance test that will be run to determine the status of this service. The test issues a request via an HTTP method to a specific URL. By default, the HTTP method used for this test is a GET but for performance reasons, should be changed to HEAD. The URL used for this request is set to point to a specific OMS server by default. If a multi-OMS system has been implemented and the OMS servers are behind a load balancer, then the URL in this section must be modified to point to the load balancer name instead of a specific server name. If this is not done and a portion of the infrastructure is down then the EM Console Service will show down as this test will fail. Recommendation: Modify the HTTP Method for the EM Console Service test and the URL if required following the detailed steps below. 1.  To create an incident rule for monitoring the EM components, click on Targets / Services. From the list of services, click on the EM Console Service. 2. On the EM Console Service page, click on the Test Performance tab. 3.  At the bottom of the page, click on the Web Transaction test called EM Console Service Test 4.  Click on the Service Tests and Beacons breadcrumb near the top of the page. 5.  Under the Service Tests section, make sure the EM Console Service Test is selected and click on the Edit push button. 6.  Under the Transaction section, make sure the Access Logout page transaction is selected and click on the Edit push button 7) Under the Request section, change the HTTP Method from the default of GET to the recommended value of HEAD. The URL in this section must be modified to point to the load balancer name instead of a specific server name if multi-OMSes have been implemented. Check for Known Issues Job Purge Repository Job is Shown as Down This issue is caused after upgrading EM from 12c to 12cR2. On the Repository page under Setup ? Manage Cloud Control ? Repository, the job called “Job Purge” is shown as down and the Next Scheduled Run is blank. Also, repvfy reports that this is a missing DBMS_SCHEDULER job. Recommendation: In EM 12cR2, the apply_purge_policies have been moved from the MGMT_JOB_ENGINE package to the EM_JOB_PURGE package. To remove this error, execute the commands below: $ repvfy verify core -test 2 -fix To confirm that the issue resolved, execute $ repvfy verify core -test 2 It can also be verified by refreshing the Job Service page in EM and check the status of the job, it should now be Up. Configure the Listener Targets in EM with the Listener Password (where required) EM will report this error every time it is encountered in the listener log file. In a RAC environment, typically the grid home and rdbms homes are owned by different OS users. The listener always runs from the grid home. Only the listener process owner can query or change the listener properties. The listener uses a password to allow other OS users (ex. the agent user) to query the listener process for parameters. EM has a default listener target metric that will query these properties. If the agent is not permitted to do this, the TNS incident (TNS-1190) will be logged in the listener’s log file. This means that the listener targets in EM also need to have this password set. Not doing so will cause many TNS incidents (TNS-1190). Below is a sample of this error from the listener log file: Recommendation: Set a listener password and include it in the configuration of the listener targets in EM For steps on setting the listener passwords, see MOS notes: 260986.1 , 427422.1

    Read the article

  • objectClass in openldap.

    - by garden air
    I am working on openldap in my linux box (centos) as testing.I create a base file to discuss with you about objectClass functionality & its impact if we not write.I write objectClass two times i.e top and domain .What does it mean ? The 2nd one is drived from the firect objectClass like parents child relation ? [root@srv1 openldap]# vim base.ldif base.ldif dn: dc=test,dc=local dc: test objectClass: top objectClass: domain Now I create add two OUs and does not add objectClass:top in both sales and marketing. To add two OUs i.e Sales and Marketing dn: ou=Sales,dc=test,dc=local ou: Sales objectClass:organizationalUnit dn: ou=Marketing,dc=test,dc=local ou: Marketing objectClass: organizationalUnit The confusion is should use all the parent objectClass and chield objectClass ? If we not add what impact will be on the structure ? In the following I use objectClass top and organizationalunit dn: ou=Sales,dc=test,dc=local ou: Sales objectClass: top objectClass:organizationalUnit dn: ou=Marketing,dc=test,dc=local ou: Marketing objectClass: top objectClass: organizationalUnit Please guide me which one is correct ? thanks garden

    Read the article

  • My Latest Books &ndash; Professional C# 2010 and Professional ASP.NET 4

    - by Bill Evjen
    My two latest books are out! Professional ASP.NET 4 in C# and VB Professional C# 4 and .NET 4 From the back covers: Take your web development to the next level using ASP.NET 4 ASP.NET is about making you as productive as possible when building fast and secure web applications. Each release of ASP.NET gets better and removes a lot of the tedious code that you previously needed to put in place, making common ASP.NET tasks easier. With this book, an unparalleled team of authors walks you through the full breadth of ASP.NET and the new and exciting capabilities of ASP.NET 4. The authors also show you how to maximize the abundance of features that ASP.NET offers to make your development process smoother and more efficient. Professional ASP.NET 4: Demonstrates ASP.NET built-in systems such as the membership and role management systems Covers everything you need to know about working with and manipulating data Discusses the plethora of server controls that are at your disposal Explores new ways to build ASP.NET, such as working with ASP.NET MVC and ASP.NET AJAX Examines the full life cycle of ASP.NET, including debugging and error handling, HTTP modules, the provider model, and more Features both printed and downloadable C# and VB code examples Start using the new features of C# 4 and .NET 4 right away The new C# 4 language version is indispensable for writing code in Visual Studio 2010. This essential guide emphasizes that C# is the language of choice for your .NET 4 applications. The unparalleled author team of experts begins with a refresher of C# basics and quickly moves on to provide detailed coverage of all the recently added language and Framework features so that you can start writing Windows applications and ASP.NET web applications immediately. Reviews the .NET architecture, objects, generics, inheritance, arrays, operators, casts, delegates, events, Lambda expressions, and more Details integration with dynamic objects in C#, named and optional parameters, COM-specific interop features, and type-safe variance Provides coverage of new features of .NET 4, Workflow Foundation 4, ADO.NET Data Services, MEF, the Parallel Task Library, and PLINQ Has deep coverage of great technologies including LINQ, WCF, WPF, flow and fixed documents, and Silverlight Reviews ASP.NET programming and goes into new features such as ASP.NET MVC and ASP.NET Dynamic Data Discusses communication with WCF, MSMQ, peer-to-peer, and syndication

    Read the article

  • Cannot connect puppet agent to puppet master

    - by u123
    I have installed puppet 3.3.1 on a debian 7 machine (test-puppet-master) and the puppet agent on another debian 7 machine (test-puppet-agent/192.11.80.246) acting as a client. I start the master with: puppet master --verbose --no-daemonize And I start the agent with: puppet agent --server=test-puppet-master --no-daemonize --verbose Notice: Did not receive certificate which gives the following output on the master: Notice: Starting Puppet master version 3.3.1 Error: Could not resolve 192.11.80.246: no name for 192.11.80.246 Info: Inserting default '~ ^/catalog/([^/]+)$' (auth true) ACL Info: Inserting default '~ ^/node/([^/]+)$' (auth true) ACL Info: Inserting default '/file' (auth ) ACL Info: Inserting default '/certificate_revocation_list/ca' (auth true) ACL Info: Inserting default '~ ^/report/([^/]+)$' (auth true) ACL Info: Inserting default '/certificate/ca' (auth any) ACL Info: Inserting default '/certificate/' (auth any) ACL Info: Inserting default '/certificate_request' (auth any) ACL Info: Inserting default '/status' (auth true) ACL Info: Not Found: Could not find certificate test-puppet-agent Error: Could not resolve 192.11.80.246: no name for 192.11.80.246 Info: Not Found: Could not find certificate test-puppet-agent Error: Could not resolve 192.11.80.246: no name for 192.11.80.246 Info: Not Found: Could not find certificate test-puppet-agent Any ideas why the agent cannot connect?

    Read the article

  • Squeeze/Lenny compilation : Library Link error

    - by PEZ
    I've got a problem here : I have a C++ Library ("DataTsBroad") and a C++ Test app ("DataTsBroadTest"), to test it. Actually, the Lib and the Test app are both compiled an a Debian Lenny. Now, i want to continue to compile my Test app on a Debian Lenny (customer constraint), but i would compile my lib on a Squeeze or a Wheezy to work on the last Debian releases. So, i successfully compiled my Lib on a Squeeze, But, after, when i try to compile my Test app with this Lib on the Lenny, it fails ! There is a Link Error : Linking CXX executable DataTsBroadTest /home/nis/pezierg/test/ProductMak/Export/DataTsBroad/L64/Release/libDataTsBroad64.so: undefined reference to `std::ctype::_M_widen_init() const@GLIBCXX_3.4.11' collect2: ld returned 1 exit status make[2]: *** [DataTsBroadTest] Error 1 make[1]: *** [CMakeFiles/DataTsBroadTest.dir/all] Error 2 make: * [all] Error 2 The problem is certainly due to ostream C++ Lib, I tried to comment all it's uses in my Lib and it works. But how can i really fix the problem ?

    Read the article

  • OpenJDK 6 B24 Available

    - by user9158633
    On November 16, 2011 the source bundle for OpenJDK 6 b24 was published at http://download.java.net/openjdk/jdk6/. The main changes in b24 are the latest round of security updates (e.g. the security changes in jdk repo) and a few other fixes.  For more information see the detailed list of all the changes in OpenJDK 6 B24. Test Results: All the jdk regression tests run with  make test passed. cd jdk6 make make test Per Kelly's  B23 Release blog: The new process is - all the jdk regression tests run with make test should just pass. Over time we will fix the tests that have been excluded, possibly add more tests, and exclude tests that fail to demonstrate stability (with a bug filed against the test). For the current list of excluded tests see  jdk6/jdk/test/ProblemList.txt file: ProblemList.html in B24  |  Latest ProblemList.txt (in the tip revision). Special thanks to Kelly O'Hair for his direction and Dave Katleman for his Release Engineering work.

    Read the article

  • Node.JS testing with Jasmine, databases, and pre-existing code

    - by Jim Rubenstein
    I've recently built the start of a core system which is likely going turn into a monster product. I'm building the system with node.js, and decided after I got a small base built, that It'd be a great idea to start using some sort of automated test suite to test the application. I decided to use jasmine, as it seems pretty solid and has a lot of features for stubbing spying and mocking methods and classes. The application has a lot of external data stores and api access (kestrel, mysql, mongodb, facebook, and more). My issue is, I've got a good amount of code written that I want to start testing - as it represents the underpinnings of the application. What are the best practices for testing methods/classes that access external APIs that I may or may not have control over? As an example, I have a data structure that fetches a bunch of data from a MySQL database. I want to test the method that retrieves the data; and I'm not sure how to go about it. I could test the fetch method which is supposed to return an array of objects, but to isolate the method from the database, I need to define my own fixture data. So what I end up doing is stubbing the mysql execution, and returning a static dataset. So, I end up writing a function that returns the dataset that makes my test pass. That doesn't seem to actually test the code, other than verifying a method is being called. I know this is kind of abstract and vague, it seems that the idea of testing is very much abstract though, so hopefully someone has some experience and can guide me in the right direction. Any advice, or reading I can do is more than welcomed. Thanks in advance.

    Read the article

  • make IIS 7.5 cache static content files over diferent pages

    - by Achilles
    On a Windows 2008 R2, using DNS and IIS I've established my development test server; i.e. I'll have a web application that I can browse on http://test.dev I've moved all the static content files like images, js files and css files into another application which is visible on http://cdn.test.dev test.dev, uses cdn.test.dev urls like http://cdn.test.dev/js/jquery.js to load js, css and images. When I first load "~/" of test.dev, all files will load with a response code of 200; when I press F5 in Firefox, all files, except the "~/default.aspx", will load with 304 response code; but pressing Ctrl+F5 loads them again with a 200 code; if I browse another url like "~/pages/" in test.dev, all of those static files will reload with a 200 code... Is this normal or I'm doing something wrong? Actually, I'm looking for a behavior like this: I want the client to load http://cdn.test.dev/js/jquery.js, only once. I want the client's browser to use this jquery.js file, from cache, in all other pages of test.dev Is this possible? This is the web.config file I have in the root directory of cdn.test.dev: <configuration> <system.webServer> <caching> <profiles> <add extension=".png" policy="CacheUntilChange" varyByHeaders="User-Agent" location="Client" /> <add extension=".gif" policy="CacheUntilChange" varyByHeaders="User-Agent" location="Client" /> <add extension=".jpg" policy="CacheUntilChange" varyByHeaders="User-Agent" location="Client" /> <add extension=".js" policy="CacheUntilChange" varyByHeaders="User-Agent" location="Client" /> <add extension=".css" policy="CacheUntilChange" varyByHeaders="User-Agent" location="Client" /> <add extension=".axd" kernelCachePolicy="CacheUntilChange" varyByHeaders="User-Agent" location="Client" /> </profiles> </caching> <httpProtocol allowKeepAlive="true"> <customHeaders> <add name="Cache-Control" value="public, max-age=31536000" /> </customHeaders> </httpProtocol> <validation validateIntegratedModeConfiguration="false" /> <modules runAllManagedModulesForAllRequests="true"> <remove name="RadUploadModule" /> <remove name="RadCompression" /> <add name="RadUploadModule" type="Telerik.Web.UI.RadUploadHttpModule" preCondition="integratedMode" /> <add name="RadCompression" type="Telerik.Web.UI.RadCompression" preCondition="integratedMode" /> </modules> <handlers> <remove name="ChartImage_axd" /> <remove name="Telerik_Web_UI_SpellCheckHandler_axd" /> <remove name="Telerik_Web_UI_DialogHandler_aspx" /> <remove name="Telerik_RadUploadProgressHandler_ashx" /> <remove name="Telerik_Web_UI_WebResource_axd" /> <add name="ChartImage_axd" path="ChartImage.axd" type="Telerik.Web.UI.ChartHttpHandler" verb="*" preCondition="integratedMode" /> <add name="Telerik_Web_UI_SpellCheckHandler_axd" path="Telerik.Web.UI.SpellCheckHandler.axd" type="Telerik.Web.UI.SpellCheckHandler" verb="*" preCondition="integratedMode" /> <add name="Telerik_Web_UI_DialogHandler_aspx" path="Telerik.Web.UI.DialogHandler.aspx" type="Telerik.Web.UI.DialogHandler" verb="*" preCondition="integratedMode" /> <add name="Telerik_RadUploadProgressHandler_ashx" path="Telerik.RadUploadProgressHandler.ashx" type="Telerik.Web.UI.RadUploadProgressHandler" verb="*" preCondition="integratedMode" /> <add name="Telerik_Web_UI_WebResource_axd" path="Telerik.Web.UI.WebResource.axd" type="Telerik.Web.UI.WebResource" verb="*" preCondition="integratedMode" /> </handlers> <security> <requestFiltering> <requestLimits maxAllowedContentLength="10485760" /> </requestFiltering> </security> <staticContent> <clientCache cacheControlMode="UseExpires" httpExpires="Wed, 01 Jan 2020 00:00:00 GMT"/> </staticContent> </system.webServer> <appSettings /> <system.web> <compilation debug="false" targetFramework="4.0" /> <pages> <controls> <add tagPrefix="telerik" namespace="Telerik.Web.UI" assembly="Telerik.Web.UI" /> </controls> </pages> <httpHandlers> <add path="ChartImage.axd" type="Telerik.Web.UI.ChartHttpHandler" verb="*" validate="false" /> <add path="Telerik.Web.UI.SpellCheckHandler.axd" type="Telerik.Web.UI.SpellCheckHandler" verb="*" validate="false" /> <add path="Telerik.Web.UI.DialogHandler.aspx" type="Telerik.Web.UI.DialogHandler" verb="*" validate="false" /> <add path="Telerik.RadUploadProgressHandler.ashx" type="Telerik.Web.UI.RadUploadProgressHandler" verb="*" validate="false" /> <add path="Telerik.Web.UI.WebResource.axd" type="Telerik.Web.UI.WebResource" verb="*" validate="false" /> </httpHandlers> <httpModules> <add name="RadUploadModule" type="Telerik.Web.UI.RadUploadHttpModule" /> <add name="RadCompression" type="Telerik.Web.UI.RadCompression" /> </httpModules> <httpRuntime maxRequestLength="10240" /> </system.web> </configuration> and this is the resulting response header for http://cdn.test.dev/css/global.css: Cache-Control: private,public, max-age=31536000 Content-Type: text/css Content-Encoding: gzip Expires: Wed, 01 Jan 2020 00:00:00 GMT Last-Modified: Mon, 06 Sep 2010 08:53:06 GMT Accept-Ranges: bytes Etag: "0454eca04dcb1:0" Vary: Accept-Encoding Server: Microsoft-IIS/7.5 X-Powered-By: ASP.NET Date: Mon, 06 Sep 2010 14:57:08 GMT Content-Length: 4495

    Read the article

  • to measure throughput of testing device connect to server via AP

    - by samantha
    Description of project- I have a test tool to which DUT connects. The test tool has an access point in it and once DUT get connected to it via mac address we check RSSI and some other features of WiFi of DUT. Now I am wondering is there is any way I can measure throughput of Device under test via mac address of DUT from server side. Test-tool has LINUX fedora 11 in it and major coding is done in c/C++ and json command. Previously, I have tried to install ftp server on test-tool and DUT can connect to it and we can measure the throughput or data transfer rate, but this is not feasible solution as it requires lot of intervention from DUT. What I am interested in is 1) To run some script on server side /test tool and it gives me throughput of bandwidth of connected device may be via mac address of DUT OR 2) Server script transfer some files/packets to DUT and we can measure the throughput. Coding is not a major challenge at this stage , I just need some tool which requires minimum intervention from DUT.

    Read the article

  • Does unit testing lead to premature generalization (specifically in the context of C++)?

    - by Martin
    Preliminary notes I'll not go into the distinction of the different kinds of test there are, there are already a few questions on these sites regarding that. I'll take what's there and that says: unit testing in the sense of "testing the smallest isolatable unit of an application" from which this question actually derives The isolation problem What is the smallest isolatable unit of a program. Well, as I see it, it (highly?) depends on what language you are coding in. Micheal Feathers talks about the concept of a seam: [WEwLC, p31] A seam is a place where you can alter behavior in your program without editing in that place. And without going into the details, I understand a seam -- in the context of unit testing -- to be a place in a program where your "test" can interface with your "unit". Examples Unit test -- especially in C++ -- require from the code under test to add more seams that would be strictly called for for a given problem. Example: Adding a virtual interface where non-virtual implementation would have been sufficient Splitting -- generalizing(?) -- a (smallish) class further "just" to facilitate adding a test. Splitting a single-executable project into seemingly "independent" libs, "just" to facilitate compiling them independently for the tests. The question I'll try a few versions that hopefully ask about the same point: Is the way that Unit Tests require one to structure an application's code "only" beneficial for the unit tests or is it actually beneficial to the applications structure. Is the generalization code need to exhibit to be unit-testable useful for anything but the unit tests? Does adding unit tests force one to generalize unnecessarily? Is the shape unit tests force on code "always" also a good shape for the code in general as seen from the problem domain? I remember a rule of thumb that said don't generalize until you need to / until there's a second place that uses the code. With Unit Tests, there's always a second place that uses the code -- namely the unit test. So is this reason enough to generalize?

    Read the article

  • Mount CIFS share with autofs

    - by Phanto
    I have a system running RHEL 5.5, and I am trying to mount a Windows share on a server using autofs. (Due to the network not being ready upon startup, I do not want to utilize fstab.) I am able to mount the shares manually, but autofs is just not mounting them. Here are the files I am working with: At the end of /etc/auto.master, I have: ## Mount this test share: /test /etc/auto.test --timeout=60 In /etc/auto.test, I have: test -fstype=cifs,username=testuser,domain=domain.com,password=password ://server/test I then restart the autofs service. However, this does not work. ls-ing the directory does not return any results. I have followed all these guides on the web, and I either don't understand them, or they.just.don't.work. Thank You

    Read the article

  • wget has a 4 second delay

    - by guisius
    Hello. I have tried to wget a page with windows/mac, and the response is instant while the linux vesion needs to wait for 4 seconds before it shows the response. I just hope this can be solved. More information added: in Ubuntu : wget xxx://192.168.0.135/test.cgi?cmd= -O test.txt --2011-03-04 14:21:17-- xxx://192.168.0.135/test.cgi?cmd= Connecting to 192.168.0.135:80... connected. HTTP request sent, awaiting response... 200 OK Length: unspecified [text/html] Saving to: `test.txt' [ <=> ] 17 --.-K/s in 0s 2011-03-04 14:21:22 (1.88 MB/s) - `test.txt' saved [17] while in Mac OS : wget xxx://192.168.0.135/test.cgi?cmd= -O test.txt --2011-03-04 14:22:33-- xxx://192.168.0.135/test.cgi?cmd= Connecting to 192.168.0.135:80... connected. HTTP request sent, awaiting response... 200 OK Length: unspecified [text/html] Saving to: `test.txt' [ <=> ] 17 --.-K/s in 0s 2011-03-04 14:22:33 (755 KB/s) - `test.txt' saved [17] in ubuntu it delays 4 seconds while windows and mac will not i believe it may related to some setting in the network config such as packet size , window frame , but i have no idea to set this PS: because the limit of the post not allow to post the url so i mark this as xxx

    Read the article

  • Can't start a service (sudo) remotely from script and keep it running

    - by Greg Bernhardt
    I have a service (tomcat) that needs sudo to be started. I made a simple script on the remote server in /root/bin/test.sh #!/bin/sh sudo service tomcat start read (The script needs to do other stuff too, just pared down for simplicity). When I run a it directly on the remote server, tomcat starts and continues running on the server after I disconnect. When I run it remotely, the process starts, (I can see it when paused for the "read"), but once the script ends, it's gone. (while paused for the read, run this command locally) ps -ef | grep tomcat I've tried various combinations of nohup, screen, and & on the commands both on the local machine and in the remote machine's test.sh script, but I can't seem to get it working. ssh -t [email protected] "/root/bin/test.sh" ssh -t [email protected] "nohup /root/bin/test.sh" ssh -t [email protected] "nohup /root/bin/test.sh &" ssh -t [email protected] "screen /root/bin/test.sh &"

    Read the article

  • Share home directory between Linux and Windows dual boot

    - by user877329
    This question is somewhat similar to How to use Windows Share has home directory, but in this case Windows is not running. I have installed a dual-boot configuration with Ubuntu 12.04 and Windows. My Windows partition is mounted on /C. Now I want either Ubuntu to locate home directories in /C/Users Which is the location of windows accounts or I want Windows to use D:\home for home directories. (D is the name of the Ubuntu root directory). For the first approach, I have managed to create a test user account test-user:x:1004:1001:Test:/C/Users/test-user:/bin/bash The account works but test-user cannot run any X session. From .xsession-errors chmod: Changing rights on ”/C/Users/test-user/.xsession-errors”: Operation not permitted Would it help get rid of that chmod, which has no effect? How do I? If I use the second approach, I need the Ext2fsd driver, which seems to work, but I am not sure if Windows maps the Ext2 system that early. Here is my fstab proc /proc proc nodev,noexec,nosuid 0 0 UUID=e7cef061-ed8d-4a82-b708-0c8f4c6f297f / ext3 errors=remount-ro 0 1 UUID=2CDCEB43DCEB0644 /C ntfs defaults,umask=007,gid=46 0 0 UUID=b087b5c0-b4bd-47e7-8d34-48ad9b192328 none swap sw 0 0 Update: I found something here: http://www.tuxera.com/community/ntfs-3g-advanced/ Will work if i do a correct mapping between NT users and Linux users.

    Read the article

  • Join Us!! Live Webinar: Using UPK for Testing

    - by Di Seghposs
    Create Manual Test Scripts 50% Faster with Oracle User Productivity Kit  Thursday, March 29, 2012 11:00 am – 12:00 pm ET Click here to register now for this informative webinar. Oracle UPK enhances the testing phase of the implementation lifecycle by reducing test plan creation time, improving accuracy, and providing the foundation for reusable training documentation, application simulations, and end-user performance support—all critical assets to support an enterprise application implementation. With Oracle UPK: Reduce manual test plan development time - Accelerate the testing cycle by significantly reducing the time required to create the test plan. Improve test plan accuracy - Capture test steps automatically using Oracle UPK and import those steps directly to any of these testing suites eliminating many of the errors that occur when writing manual tests. Create the foundation for reusable assets - Recorded simulations can be used for other lifecycle phases of the project, such as knowledge transfer for training and support. With its integration to Oracle Application Testing Suite, IBM Rational, and HP Quality Center, Oracle UPK allows you to deploy high-quality applications quickly and effectively by providing a consistent, repeatable process for gathering requirements, planning and scheduling tests, analyzing results, and managing  issues. Join this live webinar and learn how to decrease your time to deployment and enhance your testing plans today! 

    Read the article

  • How to define implementation details?

    - by woni
    In our project, an assembly combines logic for the IoC-Container, the project internals and the communication layer. The current version evolved to have only internal classes in addin assemblies. My main problem with this approach is, that the entry point is only available over the IoC-Container. It is not possible to use anything else than reflection to initialize the assembly. Everything behind the IoC-Interface is defined as implementation detail and therefore not intended for usages outside. It is well known that you should not test implementation detail (such as private and internal methods), because they should be tested through the public interface. It is also well known, that your tests should not use the IoC-Container to setup the SUTs, because that would result in too much dependencies. So we are using the InternalsVisibleTo-Attribute to make internals visible to our test assemblies and test the so called implementation details. I recognized that one problem could be the mixup between different concerns in that assembly, changing this would make this discussion useless, because classes have to be defined public. Ignoring my concerns with this, isn't the need to test a class enough reason to make it public, the usages of InternalsVisibleTo seems unintended, and a little bit "hacky". The approach to test only against the publicly available IoC-Container is too costly and would result in integration style tests. The pros of using internals are, that the usages are well known and do not have to be implemented like a public method would have to be (documentation, completeness, versioning,...). Is there a solution, to not test against internals, but keep their advantages over public classes, or do we have to redefine what an implementation detail is.

    Read the article

  • Why is a software development life-cycle so inefficient?

    - by user87166
    Currently the software development lifecycle followed in the IT company I work at is: The "Business" works with a solution manager to build a Business Requirement document The solution manager works with the Program manager to build a Functional Spec The PM works with the engineering lead to develop a release plan and with the engineering team to develop technical specifications If there are any clarifications required, developers contact the PM who contacts the solution manager who contacts the business and all the way back introducing a latency of nearly 24 hours and massive email chains for any clarifications By the time the tech spec is made, nearly 1 month has passed in back and forth Now, 2 weeks go to development while the test writes test cases Code is dropped formally to test, test starts raising bugs. Even if there is 1 root cause for 10 different issues, and its an easily fixed one, developers are not allowed to give fresh code to test for the next 1 week. After 2-3 such drops to test the code is given to the ops team as a "golden drop" ( 2 months passed from the beginning) Ops team will now deploy the code in a staging environment. If it runs stable for a week, it will be promoted to UAT and after 2 weeks of that it will be promoted to prod. If there are any bugs found here, well, applying for a visa requires less paperwork This entire process is followed even if a single SSRS report is to be released. How do other companies process such requirements? I'm wondering why, the business cannot just drop the requirements to developers, developers build and deploy to UAT themselves, expose it to the business who raise functional bugs and after fixing those promote to prod. (even for more complex stuff)

    Read the article

  • Oracle Enterprise Manager 12c Testing-as-a-Service Solution

    - by user810030
    With organizations spending as much as 50 percent of their QA time with non-test related activities like setting up hardware and deploying applications and test tools, the cloud will bring obvious benefits. A key component of Oracle Enterprise Manager our current Application Quality Management products have been helping our customers with application load testing, functional testing and test process management, but also test data management, data masking and real application testing. These products enable customers to thoroughly test applications and their underlying infrastructure to help ensure the best quality, scalability and availability prior to deployment.  Today, Oracle announced Oracle Enterprise Manager 12c Testing-as-a-Service Solution . This solution will allow users to significantly decrease the time needed to setup a complete test environment, while enhancing testing efficiency. Please read the Press Release mentioned above and join us in our Enterprise Manager LinkedIn Group discussion on this topic. (need to be a member). Or visit our booth this week during the EuroSTAR Software Testing conference in Amsterdam where we can demo this solution  I hope you find this helpfull Stay Connected: Twitter |  Facebook |  YouTube |  Linkedin |  Newsletter

    Read the article

  • Advice for outdoor wifi hardware and topology

    - by Robot
    I haven't setup any wifi networks other than an access point or two at any single location, so I'd like advice on how to setup an outdoor/weatherproof network in an area approximately 150 feet by 200 feet. The interesting thing is there are a pair of pools in the middle of the coverage area. Here is a picture: blue is pool, green is coverage area, yellow is building with wired access. Can anyone advise me on weatherproof APs, antennas and placement for best coverage of the pool deck? I've looked at the Meraki stuff, but I'm thinking it's overkill.

    Read the article

  • Simple C: atof giving wrong value [migrated]

    - by Doc
    I have a program that reads input from a singe line(string obviously) and organizes it into arrays. The problem I have is that at one point the program reads two different values and returns the first one twice. Initially I thought the program was reading the same value twice but when I tested it turned out that it got the correct one but is inputting the wrong one. for example Input: 2 0.90 0.75 0.7 0.65 sorry to snip it (while(fgets (string[test], sizeof(string[test]),ifp)) pch = strtok_r(NULL, " ", &prog); tem3 = atoi(pch); while (loop<tem3) { pch=strtok_r(NULL," ",&prog); venseatfloat[test][loop][DISCOUNT][OCCUPIED]=(float)atof(pch); printf("%f is discount\t",venseatfloat[test][loop][DISCOUNT][OCCUPIED]); pch=strtok_r(NULL, " ", &prog); strcpy(temp, pch); venseatfloat[test][loop][REGULAR][OCCUPIED]=(float)atof(pch); printf("%s is the string but %.3f is regular\n", temp ,venseatfloat[test][loop][DISCOUNT][OCCUPIED]); loop++; } output: >0.900000 is discount 0.75 is the string but 0.900 is regular >0.700000 is discount 0.65 is the string but 0.700 is regular What is going on?

    Read the article

< Previous Page | 103 104 105 106 107 108 109 110 111 112 113 114  | Next Page >