Search Results

Search found 3546 results on 142 pages for 'dos batch'.

Page 108/142 | < Previous Page | 104 105 106 107 108 109 110 111 112 113 114 115  | Next Page >

  • Parsing C#, finding methods and putting try/catch to all methods

    - by erdogany
    I know it sounds weird but I am required to put a wrapping try catch block to every method to catch all exceptions. We have thousands of methods and I need to do it in an automated way. What do you suggest? I am planning to parse all cs files and detect methods and insert a try catch block with an application. Can you suggest me any parser that I can easily use? or anything that will help me... every method has its unique number like 5006 public static LogEntry Authenticate(....) { LogEntry logEntry = null; try { .... return logEntry; } catch (CompanyException) { throw; } catch (Exception ex) { logEntry = new LogEntry( "5006", RC.GetString("5006"), EventLogEntryType.Error, LogEntryCategory.Foo); throw new CompanyException(logEntry, ex); } } I created this for this; http://thinkoutofthenet.com/index.php/2009/01/12/batch-code-method-manipulation/

    Read the article

  • Wiping Deleted Directory Entries and Defragmenting Directories

    - by Synetech inc.
    Hi, I have seen plenty of apps that wipe free space on a disk (usually by creating a file that is as big as the remaining space) or defragment a file (usually by using the MoveFile API to copy it to a new contiguous area). What I have not seen however is a program that wipes the deleted directory entries. That is, when a file is deleted, its information (name, dates, etc.) remain in the directory, but are simply marked as empty. That leaves all kinds of information in a directory entry, and also wastes space since (at least on FAT drives), the directory may be using several clusters. For example, if a directory once had a lot of files, it will be expanded to use another cluster which could be anywhere on the disk. This means that the directory is fragmented, and may be using more clusters than needed, possibly with 100’s of unused (ie, “deleted file”) entries between active files. Does anyone know of a program that can defragment/consolidate directories (ie, wipe unused entries, and move active entries together)? (I would really rather not have to resort to writing my own yet again.) Thanks a lot. EDIT Sorry, I should have said, Windows and/or DOS, for FAT*/NTFS.

    Read the article

  • Best way to produce automated exports in tab-delimited form from Teradata?

    - by Cade Roux
    I would like to be able to produce a file by running a command or batch which basically exports a table or view (SELECT * FROM tbl), in text form (default conversions to text for dates, numbers, etc are fine), tab-delimited, with NULLs being converted to empty field (i.e. a NULL colum would have no space between tab characters, with appropriate line termination (CRLF or Windows), preferably also with column headings. This is the same export I can get in SQL Assistant 12.0, but choosing the export option, using tab delimiter, setting my NULL value to '' and including column headings. I have been unable to find the right combination of options - the closest I have gotten is by building a single column with CAST and '09'XC, but the rows still have a leading 2-byte length indicator in most settings I have tried. I would prefer not to have to build large strings for the various different tables.

    Read the article

  • operator not defined for System.Data.SqlClient.SqlConnection and System.Data.SqlClient.SqlConnection

    - by Beta033
    i hope i'm just doing something wrong here. Ideally i'm trying to open the connection, open a transaction execute a ton of prebuilt sqlstatements (with parameters) against this connection then close the connection. ideally all in the same batch. It's easy enough to wrap this all in a for loop, however i'd like to use the forEach function of the list generic to set the connection as it'll probably be faster than my implementation of calling List.Item(i) in the loop but i get some strange errors. Dim sqlStatements As List(Of SqlCommand) = New List(Of SqlCommand) Dim conn As SqlClient.SqlConnection = New SqlConnection("...") sqlStatements.Item(0).Connection = conn 'Works sqlStatements.ForEach(Function(ByRef cmd As SqlCommand) cmd.Connection = conn) 'ERROR: Operator '=' is not defined for types 'System.Data.SqlClient.SqlConnection' 'and 'System.Data.SqlClient.SqlConnection What does this error really mean?

    Read the article

  • Resources to learn sh scripting 'just like a normal programming language'

    - by Homer J. Simpson
    Hi, what is the best resource (book would be nice) to learn sh scripting (the "standard" shell on Unix systems) just like when i would learn a "normal" programming/scripting language ? There are lots of tutorials on certain aspects of shell scripting, they mostly deal with shells in general and unix commands and so on, but i would rather like to find a more general approach - meaning a quick syntactic overview and an outlook on how to do things you normally do when programming, like implementing small algorithms and so on. Doing actual scripting, not just a structured batch file. And rather 100-liners than 1-to-3-liners. Can you recommend a good standard book on the topic ?

    Read the article

  • Schema Inheritance in BizTalk Server

    - by newbtdev
    Hi, I just wondering if anyone has already tried of doing something like schema inheritance in BizTalk schemas? I am using WCF Adapter and using 'consume adapter service' to generate a schema automatically, what I wanted is instead of always generating a schema and since most of my schema is the same then I want to have something like a base schema. I have this scenario that I'm testing flat file debatching, for debatching I need to set maxoccur property of the schema to '1' but for batch processing it should be '*', instead of creating a two different schemas I want just to create a base schema and inherit from it and then change the maxoccur property in the derived schema. Any help would be appreciated. Many Thanks

    Read the article

  • How to add flags to RC.EXE through QMake .pro makefiles

    - by Hernán
    I've the following definition in my .pro file: RC_FILE = app.rc This RC file contains a global include at the top: #include "version_info.h" The version_info.h header is on a common header files directory. Since RC.EXE takes INCLUDE environment variable in consideration, according to MS documentation, my build process batch sets up that accordingly: SET INCLUDE=%PROJECTDIR%\version;%INCLUDE% ... QMAKE project.pro -spec win32-msvc2008 -r CONFIG += release This works perfect as RC seems to read that INCLUDE var so the "version_info.h" file is including on every RC file properly. The problem is when I generate a VS solution (or Import it through the VS Addin). The RC invocation does not contain any /I flag (as I expect) but does not read any INCLUDE variable, even when I've setup through system 'environment variables' dialog in XP. So I'm stuck with this problem, with two alternatives I could not get to work: Make VS RC.exe invocation honour the INCLUDE variable (didn't work either as user or system variable). Force QMAKE to pass /I flag to RC invocation, and get that /I flag imported into the project settings (Resource Compiler properties). Thanks in advance.

    Read the article

  • BIOS corrupted? How to proceed? Acer Travelmate 290

    - by dtlussier
    I have a older ACER Travelmate 290 (manufactured in 2002 or 2003), which I recently tried to upgrade to Ubuntu 9.10. After doing the upgrade process it appeared as if I had a problem with my x server configuration, as on the first reboot post-install I heard the Ubuntu startup sound, but had a black screen. I thought I would then reboot again to drop down into text-mode to trouble shoot the x configuration problem. However, when I tried rebooting, something went wrong and since then when I start up the machine I get absolutely nothing except the first hardware check (i.e. HDD light flashes, CD/DVD drive spins, etc.). Other than that the screen remains totally black and I have no HDD or processor activity at all. I have tried restarting it a number of time holding down all kinds of key combinations to try and coax it into the BIOS (if possible) with no luck. I have also tried putting in both a live Linux disc and a Windows install disk without any luck. With a disk in the drive it will spin for a few seconds and then stop. All this has lead me to suspect that the BIOS is somehow corrupt (not sure about the right terminology). I have tried putting a new BIOS image and installer program downloaded from ACER on a USB key to see if it will run when I start up the machine, but no luck. I'm not sure if this method of interacting/updating/flashing the BIOS will work outside of Windows/DOS as both OSs are mentioned kind of ambiguously in the documentation. I have also taken the laptop case apart and inspected the various cards and cannot find any obviously burned out components. I'm not sure how to proceed at this point in terms of components to try, or how to try and load a new BIOS image onto the board. Any advice here would be great, especially from those with experience with this particular line of laptops. Thanks!

    Read the article

  • Does a Windows 7 dvd only have one language?

    - by user326639
    I'm a Dutch developer living in Spain. I recently composed a new computer from new parts and I installed Windows 7 Professional 64 bit (OEM) on it. On the web site of the on-line shop there was a note saying "language: Spanish". Because my English is quite a bit better than my Spanish, but mainly because it is much easier to find information on the web in English, I want my OS to be in English. I asked the on-line shop if they also sold the UK version of Windows 7 but they assured me that "all Windows 7 versions are multi-language". With the installation of XP a few years ago, I remember that I was offered the option English or Spanish while the installation process was still in the DOS-like (non-graphical) screen. While installing Windows 7, I did not see any non-graphical screen and the first time I was asked about the language, was in a drop-down list that contained only Spanish. I know about the language pack possibility of Windows 7, but this is not available on Professional. Even if I had Ultimate, I don't know if it would be possible to install Windows in Spanish, and then add English as a second language from a language pack. I get the impression that English has to be the base-language. Furthermore, I am a bit sceptical until I'd see it in action. What happens with shortcuts (i.e. Select All: ctrl-a in English / ctrl-e in Spanish, and what about logging messages in Event Viewer, etc) So can anybody tell me how it works with languages in Windows 7? Have I been misinformed by the computer shop? Could it be that OEM versions of Windows are single language an a full installation is not?

    Read the article

  • SMO missing dll on a clients

    - by Dale
    I've created an app that connects remotely to SQL Server 2008. SQL connections work and all traditional oCommand.ExecuteNonQuery(), work great! But my SMO class using server.ConnectionContext.ExecuteNonQuery(scriptfile); ERROR: missing batch parsing.dll . I can't install these independent utils on a client machines, and then take them all off when done: as suggested by: http://www.microsoft.com/downloads/details.aspx?displaylang=en&FamilyID=228de03f-3b5a-428a-923f-58a033d316e1 Since my bulk-inserts are large memory hogs containing complete tables, I wrote the tables to a temptable.sql files and used SQLCMD Util and later switch too SMO and I have the same problem. Neither of these can be leveraged on the client's PCs . Any suggestion? thanks :-)

    Read the article

  • Can't connect to samba

    - by Rick
    Windows 7, connecting to Samba shares I have a follow up question from the link above. I am running Samba 3.0.23d on FreeBSD is release 7.1 I changed the policies as described above but still cannot connect to the samba server with the windows 7 or a server 2008. I feel it is a problem with recognizing the new machines on the network. the windows machines can see the samba server, but cannot connect to it or view any of the files. After changing the security policies the samba server asked for network id and password but would not allow the machine to connect, said they were unknown username or bad password. Here is my current config file. there is no sign of encryption anywhere, should I just add the line? not sure what that would do elsewhere. Workgroup = WWOFFSET server string = WWO File Server (%v) security = server username map = /usr/local/etc/smb.users hosts allow = 10. 127. # If you want to automatically load your printer list rather # than setting them up individually then you'll need this ; load printers = yes # you may wish to override the location of the printcap file ; printcap name = /etc/printcap # on SystemV system setting printcap name to lpstat should allow # you to automatically obtain a printer list from the SystemV spool # system ; printcap name = lpstat # It should not be necessary to specify the print system type unless # it is non-standard. Currently supported print systems include: # bsd, cups, sysv, plp, lprng, aix, hpux, qnx ; printing = cups # Uncomment this if you want a guest account, you must add this to /etc/passwd # otherwise the user "nobody" is used ; guest account = pcguest # this tells Samba to use a separate log file for each machine # that connects log file = /var/log/samba/log.%m # Put a capping on the size of the log files (in Kb). max log size = 50 # Use password server option only with security = server # The argument list may include: # password server = My_PDC_Name [My_BDC_Name] [My_Next_BDC_Name] # or to auto-locate the domain controller/s # password server = * ; password server = <NT-Server-Name> password server = SERVER0 # Use the realm option only with security = ads # Specifies the Active Directory realm the host is part of ; realm = MY_REALM # Backend to store user information in. New installations should # use either tdbsam or ldapsam. smbpasswd is available for backwards # compatibility. tdbsam requires no further configuration. ; passdb backend = tdbsam ; passdb backend = smbpasswd # Using the following line enables you to customise your configuration # on a per machine basis. The %m gets replaced with the netbios name # of the machine that is connecting. # Note: Consider carefully the location in the configuration file of # this line. The included file is read at that point. ; include = /usr/local/etc/smb.conf.%m # Most people will find that this option gives better performance. # See the chapter 'Samba performance issues' in the Samba HOWTO Collection # and the manual pages for details. # You may want to add the following on a Linux system: # SO_RCVBUF=8192 SO_SNDBUF=8192 socket options = TCP_NODELAY # Configure Samba to use multiple interfaces # If you have multiple network interfaces then you must list them # here. See the man page for details. ; interfaces = 192.168.12.2/24 192.168.13.2/24 # Browser Control Options: # set local master to no if you don't want Samba to become a master # browser on your network. Otherwise the normal election rules apply ; local master = no # OS Level determines the precedence of this server in master browser # elections. The default value should be reasonable ; os level = 33 # Domain Master specifies Samba to be the Domain Master Browser. This # allows Samba to collate browse lists between subnets. Don't use this # if you already have a Windows NT domain controller doing this job ; domain master = yes # Preferred Master causes Samba to force a local browser election on startup # and gives it a slightly higher chance of winning the election ; preferred master = yes # Enable this if you want Samba to be a domain logon server for # Windows95 workstations. ; domain logons = yes # if you enable domain logons then you may want a per-machine or # per user logon script # run a specific logon batch file per workstation (machine) ; logon script = %m.bat # run a specific logon batch file per username ; logon script = %U.bat # Where to store roving profiles (only for Win95 and WinNT) # %L substitutes for this servers netbios name, %U is username # You must uncomment the [Profiles] share below ; logon path = \\%L\Profiles\%U # Windows Internet Name Serving Support Section: # WINS Support - Tells the NMBD component of Samba to enable it's WINS Server ; wins support = yes # WINS Server - Tells the NMBD components of Samba to be a WINS Client # Note: Samba can be either a WINS Server, or a WINS Client, but NOT both ; wins server = w.x.y.z # WINS Proxy - Tells Samba to answer name resolution queries on # behalf of a non WINS capable client, for this to work there must be # at least one WINS Server on the network. The default is NO. ; wins proxy = yes # DNS Proxy - tells Samba whether or not to try to resolve NetBIOS names # via DNS nslookups. The default is NO. dns proxy = no # charset settings ; display charset = ASCII ; unix charset = ASCII ; dos charset = ASCII # These scripts are used on a domain controller or stand-alone # machine to add or delete corresponding unix accounts ; add user script = /usr/sbin/useradd %u ; add group script = /usr/sbin/groupadd %g ; add machine script = /usr/sbin/adduser -n -g machines -c Machine -d /dev/null -s /bin/false %u ; delete user script = /usr/sbin/userdel %u ; delete user from group script = /usr/sbin/deluser %u %g ; delete group script = /usr/sbin/groupdel %g unix extensions = no

    Read the article

  • How to check for an existing executable before running it in a post-build event in VS2008?

    - by wtaniguchi
    Hey all, I'm trying to use SubWCRev to get the current revision number of our SVN repository and put it in a file so I can show it in the UI. As I'm working with a Web App, I use the following post build command line: "SubWCRev.exe" "$(SolutionDir)." "$(ProjectDir)Content\js\revnumber.js.tpl" "$(ProjectDir)Content\js\revnumber.js" It works great, but now I want to make sure I have SubWCRev before running it, so I can skip this post build if a fellow developer is not running TortoiseSVN. I tried a few batch codes here, but couldn't figure this out. Any ideas? Thanks!

    Read the article

  • Font for Wine that supports the entire character set of the Win32 Console?

    - by Brian Campbell
    I would like to be able to display in the Wine console all characters that the Win32 console can display. I've written a small test program to print out all 8-bit characters: #include <stdio.h> int main(int argc, char *argv[]) { int i, j; for (i = 0; i <= 0xF0; i+=0x10) { for (j = i; j <= i + 0x0F; ++j) printf("%2x:%c", j, (char)j); printf("\n"); } getchar(); return 0; } Under Wine, the best I can do so far is using Andale Mono: While this is what I see on Windows Server 2008: Is there anywhere I can legally download a font that will allow me to view all of those characters under Wine? edit I've found a set of DOS fonts that includes a CP437 font, which should cover the character set I'm interested in. However, even if I install this font, wineconsole doesn't seem to recognize it. Is there any way I can get wineconsole to use this font, or convert this font to a format that wineconsole can use? Or is there any way I can extract fonts from DOSEMU for use in Wine? Oh, and I should probably mention that I'm on Mac OS X 10.6.2, installing Wine via MacPorts, using the wine-devel package. more information I have tried installing some console fonts that should cover the full character set as Mac OS X fonts (such as the NewDOS font listed above, and a font I tried converting from the fonts supplied by DOSEMU). Wine does not seem to pick up on new fonts installed in Mac OS X. Is there a way to register new fonts I've installed with Wine? Would manually editing the system.reg file that seems to contain font mappings work, or is there something else I'd need to do? bump Bounty ends soon, I'm still looking for an answer for this. Does anyone use the Wine console for complex text user interfaces?

    Read the article

  • How to use a specific Windows SDK with MSBuild?

    - by Mac
    I have a large project made of many C++ and C# projects, and a MSBuild (3.5) script to build the whole thing. This script is based on the VCBuild (C++ projects) and MSBuild (C# projects) tasks. It is regularly executed by a Continuous Integration server. I want to be able to select a specific Windows SDK (v6.0A, v7.0, v7.1...) to be used for compilation. As I have many branches in my repository that would ultimately need a different SDK version, I need a way to select the right one before each compilation. On my computer, I have been able to setup a batch script that calls the right SetEnv.cmd before launching the MSBuild script. But this solution is not usable on the CI server as the MSBuild script is executed directly. Do you know of a way to achieve the equivalent of SetEnv.cmd under MSBuild?

    Read the article

  • OS X Hard drive recovery

    - by Adam
    I am trying to recover data from a bad Seagate 1TB hard drive in a 2010 iMac. One day the iMac wouldn't boot (stuck at gray screen on startup). I removed the hard drive from the iMac and connected it to a MacBook using a 3.5" HDD to USB adapter. The hard drive wouldn't mount but it did display in Disk Utility that that there were 2 partitions on the disk. I tried to run Disk Warrior and it showed thousands of errors but still wouldn't mount. At this time the hard drive only show one partition in Disk Utility. Next I tried putting the hard drive in a desktop PC and running Spin Rite - which then gave me several division overflow errors (even with running Spin Rite with a newer version of DOS). The SMART status on the drive reports that the drive has had failures and HD Tune referenced the drive had once hit 59 degrees celsius. Disk Utility gives me the following message when running a pair: Error: Disk Utility can’t repair this disk. Back up as many of your files as possible, reformat the disk, and restore your backed-up files. Overall, the hard drive spins up and sounds OK - there are no clicking noises but the hard drive won't mount and displays as a light gray "Macintosh HD" in disk utility. Any tips or advice on how to recover data on this drive would be GREATLY appreciated! Are there any other tools I can try before calling it quits on this drive? Thank you

    Read the article

  • Slow insert speed in Postgresql memory tablespace

    - by Prashant
    Hi, I have a requirement where I need to store the records at rate of 10,000 records/sec into a database (with indexing on a few fields). Number of columns in one record is 25. I am doing a batch insert of 100,000 records in one transaction block. To improve the insertion rate, I changed the tablespace from disk to RAM.With that I am able to achieve only 5,000 inserts per second. I have also done the following tuning in the postgres config: Indexes : no fsync : false logging : disabled Other information: - Tablespace : RAM - Number of columns in one row : 25 (mostly integers) - CPU : 4 core, 2.5 GHz - RAM : 48 GB I am wondering why a single insert query is taking around 0.2 msec on average when database is not writing anything on disk (as I am using RAM based tablespace). Is there something I am doing wrong? Help appreciated. Prashant

    Read the article

  • Best Practices: How can admin deploy software to 100s of PC ?

    - by Gopal
    Hi ... The Environment: I am working for a college. We have a couple of labs (about 100 PCs) for students. At the end of the semester, the PCs will be full of viruses, corrupt system files, all sorts of illegal downloads etc. (everything you can expect from a student environment). At the end of the semester, we would like to wipe out all the systems and do a clean install (WindowsXP + a set of application suites) to get ready for the next batch of students. Question: Is there any free software that will enable an admin to deploy a clean disk image to all the PCs in one go?

    Read the article

  • Database Version Control SQL Server 2008 Drop SP's and Functions

    - by Lieven Cardoen
    I'm working on versioning our database and now searching for a way to drop all stored procedures and functions from a C# Console Application. I'd rather not create a stored procedure that drops all stored procedures and functions. I has to be some sql executed from C#. I tried to drop the stored procedure before creating it, but I get this message: System.Data.SqlClient.SqlException: 'CREATE/ALTER PROCEDURE' must be the first statement in a query batch. Script for one SP for example: DROP PROCEDURE [dbo].[sp_Economatic_LoadJournalEntryFeedbackByData] SET ANSI_NULLS ON SET QUOTED_IDENTIFIER ON CREATE PROCEDURE [dbo].[sp_Economatic_LoadJournalEntryFeedbackByData] @Data VARCHAR(MAX) AS BEGIN ... END So I guess before creating all SP's and functions I'll need to drop all SP's and functions first with one sql script.

    Read the article

  • MYSQL Fast Insert dependent on flag from a seperate table

    - by Stuart P
    Hi all. For work I'm dealing with a large database (160 million + rows a year, 10 years of data) and have a quandary; A large percentage of the data we upload is null data and I'd like to stop it from being uploaded. The data in question is spatial in nature, so I have one table like so: idLocations (Auto-increment int, PK) X (float) Y (foat) Alwaysignore (Bool) Which is used as a reference in a second table like so: idLocations (Int, PK, "FK") idDates (Int, PK, "FK") DATA1 (float) DATA2 (float) ... DATA7 (float) So, Ideally I'd like to find a method where I can do something like: INSERT INTO tblData(idLocations, idDates, DATA1, ..., DATA7) VALUES (...), ..., (...) WHERE VALUES(idLocations) NOT LIKE (SELECT FROM tblLocation WHERE alwaysignore=TRUE ON DUPLICATE KEY UPDATE DATA1=VALUES(DATA1) So, for my large batch of input data (250 values in a block), ignore the inserts where the idLocations matches an idLocations values flagged with alwaysignore. Anyone have any suggestions? Cheers. -Stuart Other details: Running MySQL on a semi-dedicated machine, MyISAM engine for the tables.

    Read the article

  • How to send EML data in chuck to Google Apps Mail using Google API ver 2 ?

    - by Preeti
    Hi, I am migrating EML mails to Google Apps. When i try to Migrate a EML file with two attachment 2.1 MB and 1.96 MB. It is throwing exception: "The request was aborted: The request was canceled." I am using below code: MailItemEntry[] entries = new MailItemEntry[1]; String msg = File.ReadAllText(EmlPath); entries[0] = new MailItemEntry(); entries[0].Rfc822Msg = new Rfc822MsgElement(msg); ........ MailItemFeed feed = mailItemService.Batch(domain, UserName, entries); I think sending data can resolve this issue.So,how can send this EML data in chunk to Google Apps? Thanx

    Read the article

  • Run another version of Python using virtualenv

    - by mazlor
    I apologize in advance if the question is dummy ,i use Python 3.2.3 on Windows xp ,now i need Python3.3.2 , but i can't remove Python 3.2.3 because i have many codes and packages need to be run by it. I installed virtualenv to run two versions of Python in two different environments , but after that i didn't know what to do to run a code using Python 3.3.2 , here what i did: C:\>virtualenv.exe env1 C:\>env1\Scripts\activate now i don't know what to do after a folder was created its name env1 , i downloaded Python 3.3.2 and installed it in the same folder (env1) , is that correct ? then i try the following: (env1) C:\>python3.3.2 I got the following : 'python3.3.2' is not recognized as an internal or external command, operable program or batch file. also i tried : (env1) C:\>python python33 I got the following: python: can't open file 'python33': [Errno 2] No such file or directory As i mentioned , i stuck at this point , any help will be very appreciated. Thanks

    Read the article

  • How do I specify the com+ server when registering a vb6 com+ application without using clireg?

    - by user85759
    I've found lots of documentation on how to install com+ components with WiX or an exported msi from dcomcnfg but the problem with these approaches is I can't see where to specify the com+ server. Currently we register the components with clireg and the -s switch which allows us to specify the com+ server like so: clireg32.exe BLEH.VBR -s COMSERVER -t BLEH.TLB -d This is messy to say the least and I've been trying to get this into some automated form of installation that doesn't involve calling a batch file full of clireg32 calls. Currently WiX is the backbone of our packaging automation so a solution with WiX would be awesome. Thanks.

    Read the article

  • Cannot install Curb gem on Netbeans 6.9 R2

    - by Zeck
    Hi guys, I'm trying to install feedzirra. When i install curb on my netbeans i get following errors. Building native extensions. This could take a while... ERROR: Error installing curb-0.7.6.gem: ERROR: Failed to build gem native extension. "C:/Program Files/NetBeans 6.9 RC2/ruby/jruby-1.5.0/bin/jruby.bat.exe" extconf.rb '"C:/Program Files/NetBeans 6.9 RC2/ruby/jruby-1.5.0/bin/jruby.bat.exe"' is not recognized as an internal or external command, operable program or batch file. Gem files will remain installed in C:/Program Files/NetBeans 6.9 RC2/ruby/jruby-1.5.0/lib/ruby/gems/1.8/gems/curb-0.7.6 for inspection. Results logged to C:/Program Files/NetBeans 6.9 RC2/ruby/jruby-1.5.0/lib/ruby/gems/1.8/gems/curb-0.7.6/ext/gem_make.out Any ideas how I can get this to work? Or did you know very fast feed parser gem?

    Read the article

  • ETL mechanisms for MySQL to SQL Server over WAN

    - by Troy Hunt
    I’m looking for some feedback on mechanisms to batch data from MySQL Community Server 5.1.32 with an external host down to an internal SQL Server 05 Enterprise machine over VPN. The external box accumulates data throughout business hours (about 100Mb per day), which then needs to be transferred internationally across a WAN connection to an internal corporate environment before some BI work is performed. This should just be change-sets making their way down each night. I’m interested in thoughts on the ETL mechanisms people have successfully used in similar scenarios before. SSIS seems like a potential candidate; can anyone comment on the suitability for this scenario? Alternatively, other thoughts on how to do this in a cost-conscious way would be most appreciated. Thanks!

    Read the article

  • 404 not found in telnet, works fine in browser

    - by Viranch Mehta
    i am having a very irritating problem, when i open a url ( http://celebs.widewallpapers.net/md/a/adriana-lima/1440/Adriana-Lima-1440x900-002.jpg ) in browser, it works fine.. but when i try to access it by telnet on bash, i get 404 not found!! my exact terminal: $ telnet celebs.widewallpapers.net 80 HEAD /md/a/adriana-lima/1440/Adriana-Lima-1440x900-002.jpg HTTP/1.0 [enter] [enter] HTTP/1.1 404 Not Found Server: nginx Date: Sun, 23 May 2010 21:36:05 GMT Content-Type: text/html; charset=windows-1251 Content-Length: 166 Connection: close please help me with this as i m trying to make a C batch-downloader, which is almost working as same as the telnet.

    Read the article

< Previous Page | 104 105 106 107 108 109 110 111 112 113 114 115  | Next Page >