Search Results

Search found 4223 results on 169 pages for 'intel vt x'.

Page 108/169 | < Previous Page | 104 105 106 107 108 109 110 111 112 113 114 115  | Next Page >

  • Virtualized data centre&ndash;Part three: Architecture

    - by marc dekeyser
    Having the basics (like discussed in the previous articles) is all good and well, but how do we get started on this?! It can be quite daunting after all!   From my own point of view I can absolutely confirm your worries and concerns, but also tell you that it is not as hard as it seems! Deciding on what kind of motherboard to buy, processor and how much memory is an activity you will spend quite some time doing research on. And that is not even mentioning storage! All in all it comes down to setting you expectations and your budget. Probably adjusting your expectations according to your budget :). Processors As a rule of thumb you want VT-D (virtualization) technology built in to the processor allowing you to have 64 bit machines running on your host. Memory The more the better! If you are building a home lab don’t bother with ECC unless you are going to run machines that absolutely should be on all the time and your comfort depends on it! Motherboard Depends on what you are going to do with storage: If you are going the NAS way then the number of SATA port/RAID capabilities do not really matter. If you decide to have a single server with lots of dedicated storage it obviously matters how much SATA ports you will have, alternatively you could use a RAID controller (but these set you back a pretty penny if you want one. DELL 6i’s are usually available for a good bargain if you can find one!). Easiest is to get one with a built-in graphics card (on-board) as you are just adding more heat, power usage and possible points of failure. Networking Just like your choice of motherboard the networking side tends to depend on how you want to go. A single virtualization  host with local storage can usually get away with having a single network card, a cluster or server which uses iSCSI storage tends to have more than one teamed up :). Storage The dreaded beast from the dark! The horror which lives in the forest! The most difficult decision you are going to make in the building of your lab. Why you might ask? Simple my friend, having the right choice of storage can make or break your virtualization solution. The performance of you storage choice will have an important impact on the responsiveness of your virtual machines and the deployment of new machines. It also makes a run with your budget! If you decide to go the NAS route you will be dropping a lot more money than if you would be having just a bunch of disks sitting in a server and manually distributing the virtual machines over the disks. Platform I’m a Microsoftee so Hyper-V is a dead giveaway for me. If you are interested in using VMware I won’t stop you but the rest of my posts will be oriented on Server 2012 Hyper-V (aka 3.0)! What did I use? Before someone asks me this in the comments I’ll give you a quick run down of what I am using. - Intel 2.4 quad core processors (i something something) - 24 GB DDR3 Memory - Single disk in each server (might look at this as I move the servers to 2012) - Synology DS1812+ NAS - 3 network interfaces where possible - HP1800 procurve managed switch I decided to spring for the NAS as I will also be using it for backups and media storage (which is working out quite nicely with my Xbox 360 I must say). At the time of building my 2 boxes (over a year and a half ago) these set me back about 900 euros each so I can image you can build the same or better for a lower price. Next article will be diagramming what I want to achieve and starting a build on the Hyper V 3.0 cluster!

    Read the article

  • X server with nvidia driver crashing: 12.04

    - by Raster
    My X server consistently crashes. It seems like this is happening when the X server is idle. This behaviour is new with 12.04. This is only happening on the second display of a multiseat system. Is there a configuration change I can make to stop this? X.Org X Server 1.11.3 Release Date: 2011-12-16 X Protocol Version 11, Revision 0 Build Operating System: Linux 2.6.42-26-generic x86_64 Ubuntu Current Operating System: Linux Desktop 3.2.0-29-generic #46-Ubuntu SMP Fri Jul 27 17:03:23 UTC 2012 x86_64 Kernel command line: BOOT_IMAGE=/vmlinuz-3.2.0-29-generic root=/dev/mapper/Group1-Root ro ramdisk_size=512000 quiet splash vt.handoff=7 Build Date: 04 August 2012 01:51:23AM xorg-server 2:1.11.4-0ubuntu10.7 (For technical support please see http://www.ubuntu.com/support) Current version of pixman: 0.24.4 Before reporting problems, check http://wiki.x.org to make sure that you have the latest version. Markers: (--) probed, (**) from config file, (==) default setting, (++) from command line, (!!) notice, (II) informational, (WW) warning, (EE) error, (NI) not implemented, (??) unknown. (==) Log file: "/var/log/Xorg.1.log", Time: Sun Sep 2 22:37:06 2012 (==) Using config file: "/etc/X11/xorg.conf" (==) Using system config directory "/usr/share/X11/xorg.conf.d" Backtrace: 0: /usr/bin/X (xorg_backtrace+0x26) [0x7fcee86be846] 1: /usr/bin/X (0x7fcee8536000+0x18c6ea) [0x7fcee86c26ea] 2: /lib/x86_64-linux-gnu/libpthread.so.0 (0x7fcee785c000+0xfcb0) [0x7fcee786bcb0] 3: /usr/lib/x86_64-linux-gnu/xorg/extra-modules/nvidia_drv.so (0x7fcee14ba000+0x902a9) [0x7fcee154a2a9] 4: /usr/lib/x86_64-linux-gnu/xorg/extra-modules/nvidia_drv.so (0x7fcee14ba000+0xfd5e7) [0x7fcee15b75e7] 5: /usr/lib/x86_64-linux-gnu/xorg/extra-modules/nvidia_drv.so (0x7fcee14ba000+0x4d6b92) [0x7fcee1990b92] 6: /usr/lib/x86_64-linux-gnu/xorg/extra-modules/nvidia_drv.so (0x7fcee14ba000+0x4d74d5) [0x7fcee19914d5] 7: /usr/lib/x86_64-linux-gnu/xorg/extra-modules/nvidia_drv.so (0x7fcee14ba000+0x4d767d) [0x7fcee199167d] 8: /usr/bin/X (0x7fcee8536000+0x1196ec) [0x7fcee864f6ec] 9: /usr/bin/X (0x7fcee8536000+0xe8ad5) [0x7fcee861ead5] 10: /usr/bin/X (0x7fcee8536000+0xe9d45) [0x7fcee861fd45] /etc/X11/xorg.conf Section "ServerLayout" Identifier "Desktop" Screen 0 "DesktopScreen" 0 0 InputDevice "DesktopMouse" "CorePointer" InputDevice "DesktopKeyboard" "CoreKeyboard" Option "AutoAddDevices" "false" Option "AllowEmptyInput" "true" Option "AutoEnableDevices" "false" EndSection Section "ServerLayout" Identifier "Desktop2" Screen 1 "Desktop2Screen" 0 0 InputDevice "Desktop2Mouse" "CorePointer" InputDevice "Desktop2Keyboard" "CoreKeyboard" Option "AutoAddDevices" "false" Option "AllowEmptyInput" "true" Option "AutoEnableDevices" "false" EndSection Section "Module" Load "dbe" Load "extmod" Load "type1" Load "freetype" Load "glx" EndSection Section "Files" EndSection Section "ServerFlags" Option "AutoAddDevices" "false" Option "AutoEnableDevices" "false" Option "AllowMouseOpenFail" "on" Option "AllowEmptyInput" "on" Option "ZapWarning" "on" Option "HandleSepcialKeys" "off" # Zapping on Option "DRI2" "on" Option "Xinerama" "0" EndSection # Desktop Mouse Section "InputDevice" Identifier "DesktopMouse" Driver "evdev" Option "Device" "/dev/input/event3" Option "Protocol" "auto" Option "GrabDevice" "on" Option "Emulate3Buttons" "no" Option "Buttons" "5" Option "ZAxisMapping" "4 5" Option "SendCoreEvents" "true" EndSection # Desktop2 Mouse Section "InputDevice" Identifier "Desktop2Mouse" Driver "evdev" Option "Device" "/dev/input/event5" Option "Protocol" "auto" Option "GrabDevice" "on" Option "Emulate3Buttons" "no" Option "Buttons" "5" Option "ZAxisMapping" "4 5" Option "SendCoreEvents" "true" EndSection Section "InputDevice" Identifier "DesktopKeyboard" Driver "evdev" Option "Device" "/dev/input/event4" Option "XkbRules" "xorg" Option "XkbModel" "105" Option "XkbLayout" "us" Option "Protocol" "Standard" Option "GrabDevice" "on" EndSection Section "InputDevice" Identifier "Desktop2Keyboard" Driver "evdev" Option "Device" "/dev/input/event6" Option "XkbRules" "xorg" Option "XkbModel" "105" Option "XkbLayout" "us" Option "Protocol" "Standard" Option "GrabDevice" "on" EndSection Section "Monitor" Identifier "Desktop2Monitor" VendorName "Acer" ModelName "Acer G235H" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" Identifier "DesktopMonitor" VendorName "Acer" ModelName "Acer H213H" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Device" Identifier "EVGACard" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "GeForce GTX 560 Ti" Option "Coolbits" "1" BusID "PCI:2:0:0" Screen 0 EndSection Section "Device" Identifier "XFXCard" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "GeForce GTX 9800" Option "Coolbits" "1" BusID "PCI:5:0:0" Screen 0 EndSection Section "Screen" Identifier "DesktopScreen" Device "EVGACard" Monitor "DesktopMonitor" DefaultDepth 24 SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "Desktop2Screen" Device "XFXCard" Monitor "Desktop2Monitor" DefaultDepth 24 SubSection "Display" Depth 24 EndSubSection EndSection

    Read the article

  • Word automation - SaveAs

    - by nXqd
    I try to write a simple MFC - Word Automation to save for every 1 minute. I follow this article : http://www.codeproject.com/KB/office/MSOfficeAuto.aspx And this is what Im trying to implement , I'm new to COM so I think there's problem here: my VBA is generated by Word 2010: ActiveDocument.SaveAs2 FileName:="1.docx", FileFormat:=wdFormatXMLDocument _ , LockComments:=False, Password:="", AddToRecentFiles:=True, _ WritePassword:="", ReadOnlyRecommended:=False, EmbedTrueTypeFonts:=False, _ SaveNativePictureFormat:=False, SaveFormsData:=False, SaveAsAOCELetter:= _ False, CompatibilityMode:=14 And my code to implement VBA code above : { COleVariant varName(L"b.docx"); COleVariant varFormat(L"wdFormatXMLDocument"); COleVariant varLockCmt((BYTE)0); COleVariant varPass(L""); COleVariant varReadOnly((BYTE)0); COleVariant varEmbedFont((BYTE)0); COleVariant varSaveNativePicFormat((BYTE)0); COleVariant varForms((BYTE)0); COleVariant varAOCE((BYTE)0); VARIANT x; x.vt = VT_I4; x.lVal = 14; COleVariant varCompability(&x);; VARIANT result; VariantInit(&result); _hr=OLEMethod( DISPATCH_METHOD, &result, pDocApp, L"SaveAs2",10, varName.Detach(),varFormat.Detach(),varLockCmt.Detach(),varPass.Detach(),varReadOnly.Detach(), varEmbedFont.Detach(),varSaveNativePicFormat.Detach(),varForms.Detach(),varAOCE.Detach(),varCompability.Detach() ); } I get no error from this one, but it doesn't work.

    Read the article

  • How to capture page with google map?

    - by Max
    I have a UIComponent with Google map in the continer. I need to capture this container for making a preview. My integration looks like the following: <mx:UIComponent id="mapContainer" width="410" height="300" /> googleMap = new Map(); mapContainer.addChild(googleMap); But if I do("this" - is my UIComponent) var bmd:BitmapData = new BitmapData(this.width, this.height, true, 0x00ffffff); bmd.draw(this); I see the following: An ActionScript error has occurred: SecurityError: Error #2123: Security sandbox violation: BitmapData.draw: http://localhost/ cannot access http://mt1.google.com/vt/lyrs=m@121&hl=en&src=api&x=1&y=1&z=1&s=Gali. No policy files granted access. at flash.display::BitmapData/draw() I now, that I can to add it host to allowed on the custom client. But I need to have working system on any computer ) I've tried to hide it: templateGoogleMapRenderer.mapContainer.setVisible(false); templateGoogleMapRenderer.mapContainer.includeInLayout = false; But it was unsuccessfully. May be I can override some method in my UIComponent, that flex use during BitmapData/draw() ? Capture with hidden map is success result for me )

    Read the article

  • Crystal reports 11 RDC (COM API) displays printer dialog even when I tell it not to prompt

    - by bdonlan
    I'm using Crystal Reports 11's RDC (COM) API to print. My code looks like this: HRESULT res = m_Report->SelectPrinter(b_driver, b_device, b_port); if (FAILED(res)) return res; // For these calls, the #import wrapper throws on error m_Report->PutPrinterDuplex(dmDuplex); m_Report->PutPaperSize(dmPaperSize); m_Report->PutPaperSource((CRPaperSource)pdlg->GetDevMode()->dmDefaultSource); if (m_Report->GetPaperOrientation() == crDefaultPaperOrientation) m_Report->PutPaperOrientation(crPortrait); VARIANT vfalse; VariantInit(&vfalse); vfalse.vt=VT_BOOL; vfalse.boolVal=0; res = m_Report->PrintOut(vfalse); However, at the end of all this, crystal reports still shows its own printer selection dialog - but only for some reports, it seems. Why does crystal reports show a print dialog even when I pass false for promptUser? And how, then, can I suppress crystal reports' internal printer selection dialog and force it to use my values? Edit: Whoops, CR11, not CR9. Some further information: The reports that work properly (ie, do not show the print dialog) are generated internally using the RDC API; we create a new report object, import subreports into it, then print the result. No problem there. The reports that do not work properly (ie, force the print dialog to open) have been created with a previous version of crystal reports; however, opening and saving the report does not seem to help. Sample reports in the Crystal Reports installation directory show the same problem. I tried reproducing with VBScript; however, the result was that nothing was printed at all (no dialog, no nothing): Set app = CreateObject("CrystalRuntime.Application.11") Set report = app.OpenReport("C:\Program Files\Business Objects\Crystal Reports 11.5\Samples\en\Reports\General Business\Inventory Crosstab.rpt") report.PrintOut(True) rem Testing with a True parameter to force a print dialog - but no printout and nothing appears (no error either though)

    Read the article

  • Delphi - Is there a better way to get state abbreviations from state names

    - by Bill
    const states : array [0..49,0..1] of string = ( ('Alabama','AL'), ('Montana','MT'), ('Alaska','AK'), ('Nebraska','NE'), ('Arizona','AZ'), ('Nevada','NV'), ('Arkansas','AR'), ('New Hampshire','NH'), ('California','CA'), ('New Jersey','NJ'), ('Colorado','CO'), ('New Mexico','NM'), ('Connecticut','CT'), ('New York','NY'), ('Delaware','DE'), ('North Carolina','NC'), ('Florida','FL'), ('North Dakota','ND'), ('Georgia','GA'), ('Ohio','OH'), ('Hawaii','HI'), ('Oklahoma','OK'), ('Idaho','ID'), ('Oregon','OR'), ('Illinois','IL'), ('Pennsylvania','PA'), ('Indiana','IN'), ('Rhode Island','RI'), ('Iowa','IA'), ('South Carolin','SC'), ('Kansas','KS'), ('South Dakota','SD'), ('Kentucky','KY'), ('Tennessee','TN'), ('Louisiana','LA'), ('Texas','TX'), ('Maine','ME'), ('Utah','UT'), ('Maryland','MD'), ('Vermont','VT'), ('Massachusetts','MA'), ('Virginia','VA'), ('Michigan','MI'), ('Washington','WA'), ('Minnesota','MN'), ('West Virginia','WV'), ('Mississippi','MS'), ('Wisconsin','WI'), ('Missouri','MO'), ('Wyoming','WY') ); function getabb(state:string):string; var I:integer; begin for I := 0 to length(states) -1 do if lowercase(state) = lowercase(states[I,0]) then begin result:= states[I,1]; end; end; function getstate(state:string):string; var I:integer; begin for I := 0 to length(states) -1 do if lowercase(state) = lowercase(states[I,1]) then begin result:= states[I,0]; end; end; procedure TForm2.Button1Click(Sender: TObject); begin edit1.Text:=getabb(edit1.Text); end; procedure TForm2.Button2Click(Sender: TObject); begin edit1.Text:=getstate(edit1.Text); end; end. Is there a bette way to do this?

    Read the article

  • How do I set default search conditions with Searchlogic?

    - by Danger Angell
    I've got a search form on this page: http://staging-checkpointtracker.aptanacloud.com/events If you select a State from the dropdown you get zero results because you didn't select one or more Event Division (checkboxes). What I want is to default the checkboxes to "checked" when the page first loads...to display Events in all Divisions...but I want changes made by the user to be reflected when they filter. Here's the index method in my Events controller: def index @search = Event.search(params[:search]) respond_to do |format| format.html # index.html.erb format.xml { render :xml => @events } end end Here's my search form: <% form_for @search do |f| %> <div> <%= f.label :state_is, "State" %> <%= f.select :state_is, ['AK','AL','AR','AZ','CA','CO','CT','DC','DE','FL','GA','HI','IA','ID','IL','IN','KS','KY','LA','MA','MD','ME','MI','MN','MO','MS','MT','NC','ND','NE','NH','NJ','NM','NV','NY','OH','OK','OR','PA','RI','SC','SD','TN','TX','UT','VA','VT','WA','WI','WV','WY'], :include_blank => true %> </div> <div> <%= f.check_box :division_like_any, {:name => "search[:division_like_any][]"}, "Sprint", :checked => true %> Sprint (2+ hours)<br/> <%= f.check_box :division_like_any, {:name => "search[:division_like_any][]"}, "Sport" %> Sport (12+ hours)<br/> <%= f.check_box :division_like_any, {:name => "search[:division_like_any][]"}, "Adventure" %> Adventure (18+ hours)<br/> <%= f.check_box :division_like_any, {:name => "search[:division_like_any][]"}, "Expedition" %> Expedition (48+ hours)<br/> </div> <%= f.submit "Find Events" %> <%= link_to 'Clear', '/events' %> <% end %>

    Read the article

  • How to modify ASCII table in C ? [closed]

    - by drigoSkalWalker
    Like this: My ASCII Chart 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI 1 DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 2 SP ! " # $ % & ' ( ) * + , - . / 3 0 1 2 3 4 5 6 7 8 9 : ; ? 4 @ A B C D E F G H I J K L M N O 5 P Q R S T U V W X Y Z [ \ ] ^ _ 6 ` a b c d e f g h i j k l m n o 7 p q r s t u v w x y z { | } ~ DEL I want to call a function, alter the ASCII sequence in this function and when it returns, the ASCII sequence back to the original. Thanks in advance! EDIT: What I want is it: I want to change the order of chars, for examble, A is 65, if I want to make A equal a 0? without to make a function to do it, for example, I could accomplish it with a function that compare an array of chars, and store it in another way with the correct value (the new table), but do it is too expensive, is there another way? thanks in advance again!

    Read the article

  • What is the header of an array in .NET

    - by Thomas
    Hi all, I have a little bit seen the representation of an array in memory with Windbg and SOS plugin. Here it is the c# : class myobj{ public int[] arr; } class Program{ static void Main(string[] args){ myobj o = new myobj(); o.arr = new int[7]; o.arr[0] = 0xFFFFFF; o.arr[1] = 0xFFFFFF; o.arr[2] = 0xFFFFFF; o.arr[3] = 0xFFFFFF; o.arr[4] = 0xFFFFFF; } } I break at final of Main, and I observ : 0:000> !clrstack -l OS Thread Id: 0xc3c (0) ESP EIP 0015f0cc 0043d1cf test.Program.Main(System.String[]) LOCALS: 0x0015f0d8 = 0x018a2f58 0:000 !do 0x018a2f58 Name: test.myobj MethodTable: 0026309c EEClass: 00261380 Size: 12(0xc) bytes (C:\Users\admin\Documents\Visual Studio 2008\Projects\test\test\bin\Debug\test.exe) Fields: MT Field Offset Type VT Attr Value Name 01324530 4000001 4 System.Int32[] 0 instance 018a2f64 tab 0:000 dd 018a2f64 018a2f64 01324530 00000007 00ffffff 00ffffff 018a2f74 00ffffff 00ffffff 00ffffff 00000000 018a2f84 00000000 00000000 00000000 00000000 018a2f94 00000000 00000000 00000000 00000000 018a2fa4 00000000 00000000 00000000 00000000 018a2fb4 00000000 00000000 00000000 00000000 018a2fc4 00000000 00000000 00000000 00000000 018a2fd4 00000000 00000000 00000000 00000000 I can see that the header contains the size of the array (00000007) but my question is : what is the value 01324530 ? Thanks !

    Read the article

  • how to display my list with n amount on each line in Python

    - by user1786698
    im trying to display my list with 7 states on each line here is what i have so far, but it displays as one long string of all the states with quotes around each state. I forgot to mention that this is for my CS class and we havent learned iter yet so we not allowed to use it. the only hint i was given was to to turn STATE_LIST into a string then use '\n' to break it up state = str(STATE_LIST) displaystates = Text(Point(WINDOW_WIDTH/2, WINDOW_HEIGHT/2), state.split('\n')) displaystates.draw(win) and STATE_LIST looks like this STATE_VOTES = { "AL" : 9, # Alabama "AK" : 3, # Alaska "AZ" : 11, # Arizona "AR" : 6, # Arkansas "CA" : 55, # California "CO" : 9, # Colorado "CT" : 7, # Connecticut "DE" : 3, # Delaware "DC" : 3, # Washington DC "FL" : 29, # Florida "GA" : 16, # Georgia "HI" : 4, # Hawaii "ID" : 4, # Idaho "IL" : 20, # Illinois "IN" : 11, # Indiana "IA" : 6, # Iowa "KS" : 6, # Kansas "KY" : 8, # Kentucky "LA" : 8, # Louisiana "ME" : 4, # Maine "MD" : 10, # Maryland "MA" : 11, # Massachusetts "MI" : 16, # Michigan "MN" : 10, # Minnesota "MS" : 6, # Mississippi "MO" : 10, # Missouri "MT" : 3, # Montana "NE" : 5, # Nebraska "NV" : 6, # Nevada "NH" : 4, # New Hampshire "NJ" : 14, # New Jersey "NM" : 5, # New Mexico "NY" : 29, # New York "NC" : 15, # North Carolina "ND" : 3, # North Dakota "OH" : 18, # Ohio "OK" : 7, # Oklahoma "OR" : 7, # Oregon "PA" : 20, # Pennsylvania "RI" : 4, # Rhode Island "SC" : 9, # South Carolina "SD" : 3, # South Dakota "TN" : 11, # Tennessee "TX" : 38, # Texas "UT" : 6, # Utah "VT" : 3, # Vermont "VA" : 13, # Virginia "WA" : 12, # Washington "WV" : 5, # West Virginia "WI" : 10, # Wisconsin "WY" : 3 # Wyoming } STATE_LIST = sorted(list(STATE_VOTES.keys())) I am trying to get it to look somewhat like this

    Read the article

  • Getting Started with Boxee

    - by DigitalGeekery
    Boxee is a free Media PC application that runs on Windows, Mac, and Ubuntu Linux. With Boxee, you can integrate online video, music and pictures, with your own local media and social networking. Today we are going to take a closer look at Boxee and some of it’s features. Note: We used Windows 7 for this tutorial. Your experience on a Mac or Ubuntu Linux build may vary slightly. Hardware Requirements x86 (Intel/AMD processor) based system running at 1.0GHz or greater 512MB system memory (RAM) or more Video card capable of OpenGL 1.4, Direct X 9.0 Software Requirements Mac OS X 10.4+ (Intel based processor) Ubuntu Linux 9.04+ x86 only Windows XP / Vista / 7 (64 bit in Vista or 7) Installing Boxee Before downloading and installing Boxee, you’ll need to register for a free account. (See link below) Once your account is registered and verified, you’ll be able to log in and download the application. Installation is pretty straightforward…just take the defaults. Boxee will open in full screen mode and you’ll be prompted to login with your username and password. Before you login, you may want to take a moment to click on the “Guide” icon and learn a bit about navigating in Boxee. Some basic keyboard navigation is as follows. Move right, left, up, & down with the arrow keys. Hit “Enter” to make a selection, the forward slash key “\” to toggle between full screen and windowed mode, and “Esc” to go back to the previous screen. For Playback, the volume is controlled by plus & minus (+/-) keys, you can Play / Pause using the spacebar, and skip using the arrow keys. Boxee will also work with any infrared remote. If you have an iPhone or iPod Touch you can download software to enable them as a Boxee remote. If you’re using a mouse and keyboard, hover over the username and password boxes to enter your login credentials. If using a a remote, click your OK button and enter credentials with the on screen keyboard. Click “Done” when finished.   When you are ready to login, enter your credentials and click “Login.” On first login, you’ll be prompted to calibrate your screen. If you choose “Skip” you can always calibrate your screen later under Settings > Appearance > Screen. When Boxee opens, you’ll be greeted by the Home screen. To the left will be your Feeds. This will be any recommended content from friends on Boxee, and social networks such as Facebook and Twitter. Although, when you first login, it will mainly be info from the Boxee staff. You’ll have “Featured” content in the center and your Queue on the right. You’ll also have the Menu along the top.   Pop Up Menu The Pop Menu can be accessed by hitting the “Esc” key, or back on your remote. Depending on where you are located in Boxee, you may have to hit it a few time to “back out” to the Pop Up menu. From the Pop Up Menu, you can easily access any of the resources, settings, and favorites. Queue The Queue is your playlist of TV shows, movies, or Internet videos you wish to watch. When you find an offering you’d like to watch, select it and then click “Add to Queue.” The selected item will be added to your Queue and can be accessed at any time from the Menu. TV Show Library The TV Show library can contain files from your local hard drive or streaming content from the Web. Boxee pulls content from a variety of online locations such as Hulu and TV network sites. Click on the show to see which specific episodes are currently available. To search for your favorite shows, click on the yellow arrow to the left, or navigate to the left with your keyboard or remote. Enter your selection into the search box. My Apps By default, the “My Apps” section includes a list of the most popular apps, such as Netflix, Pandora, YouTube, and others. You can remove Apps from “My Apps,” or add new Apps from the Apps Library.   To access all the available Apps, click on the left arrow button, or click on the yellow arrow at the left, then select “App Library.” Choose an App from the Library and click it to open… … and then select “Add to My Apps.” Or, you can click start to play the App if you don’t wish to Add it to your “My Apps.”   Music, Pictures, and Movies Boxee will scan your PC for movies, pictures, and music. You can choose to scan specific folders by clicking on “Scan Media Folders…” … or from the Pop Up Menu, selecting Settings > Media, and then browsing for your media.   Conclusion Boxee to be a great way to integrate your local media with online streaming content. It can be run as an application on your home PC, or as a stand alone media PC. It should also be noted, however, that your access to online content will vary depending on your country. If you are a Windows Media Center user and and want to add the additional features of Boxee, check out our article on integrating Boxee with Windows 7 Media Center. Download Boxee Similar Articles Productive Geek Tips Integrate Boxee with Media Center in Windows 7Disable Fast User Switching on Windows XPOops! Sorry About the Feed ErrorsDisplay a list of Started Services from the Command Line (Windows)Feedburner to Google: Worst Transition Ever. TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional Discover New Bundled Feeds in Google Reader Play Music in Chrome by Simply Dragging a File 15 Great Illustrations by Chow Hon Lam Easily Sync Files & Folders with Friends & Family Amazon Free Kindle for PC Download Stretch popurls.com with a Stylish Script (Firefox)

    Read the article

  • Slow NFS and GFS2 performance

    - by Tiago
    Recently I've designed and configured a 4 node cluster for a webapp that does lots of file handling. The cluster have been broken down into 2 main roles, webserver and storage. Each role is replicated to a second server using drbd in active/passive mode. The webserver does a NFS mount of the data directory of the storage server and the latter also has a webserver running to serve files to browser clients. In the storage servers I've created a GFS2 FS to hold the data which is wired to drbd. I've chose GFS2 mainly because the announced performance and also because the volume size which has to be pretty high. Since we entered production I've been facing two problems that I think are deeply connected. First of all, the NFS mount on the webservers keeps hanging for a minute or so and then resumes normal operations. By analyzing the logs I've found out that NFS stops answering for a while and outputs the following log lines: Oct 15 18:15:42 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:44 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:46 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:47 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:47 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:47 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:48 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:48 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:51 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:52 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:52 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:55 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:55 <server hostname> kernel: nfs: server active.storage.vlan not responding, still trying Oct 15 18:15:58 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK Oct 15 18:15:59 <server hostname> kernel: nfs: server active.storage.vlan OK In this case, the hang lasted for 16 seconds but sometimes it takes 1 or 2 minutes to resume normal operations. My first guess was this was happening due to heavy load of the NFS mount and that by increasing RPCNFSDCOUNT to a higher value, this would become stable. I've increased it several times and apparently, after a while, the logs started appearing less times. The value is now on 32. After further investigating the issue, I've came across a different hang, despite the NFS messages still appear in the logs. Sometimes, the GFS2 FS simply hangs which causes both the NFS and the storage webserver to serve files. Both stay hang for a while and then they resume normal operations. This hangs leaves no trace on client side (also leaves no NFS ... not responding messages) and, on the storage side, the log system appears to be empty, even though the rsyslogd is running. The nodes connect themselves through a 10Gbps non-dedicated connection but I don't think this is an issue because the GFS2 hang is confirmed but connecting directly to the active storage server. I've been trying to solve this for a while now and I've tried different NFS configuration options, before I've found out the GFS2 FS is also hanging. The NFS mount is exported as such: /srv/data/ <ip_address>(rw,async,no_root_squash,no_all_squash,fsid=25) And the NFS client mounts with: mount -o "async,hard,intr,wsize=8192,rsize=8192" active.storage.vlan:/srv/data /srv/data After some tests, these were the configurations that yielded more performance to the cluster. I am desperate to find a solution for this as the cluster is already in production mode and I need to fix this so that this hangs won't happen in the future and I don't really know for sure what and how I should be benchmarking. What I can tell is that this is happening due to heavy loads as I have tested the cluster earlier and this problems weren't happening at all. Please tell me if you need me to provide configuration details of the cluster, and which do you want me to post. As last resort I can migrate the files to a different FS but I need some solid pointers on whether this will solve this problems as the volume size is extremely large at this point. The servers are being hosted by a third-party enterprise and I don't have physical access to them. Best regards. EDIT 1: The servers are physical servers and their specs are: Webservers: Intel Bi Xeon E5606 2x4 2.13GHz 24GB DDR3 Intel SSD 320 2 x 120GB Raid 1 Storage: Intel i5 3550 3.3GHz 16GB DDR3 12 x 2TB SATA Initially there was a VRack setup between the servers but we've upgraded one of the storage servers to have more RAM and it wasn't inside the VRack. They connect through a shared 10Gbps connection between them. Please note that it is the same connection that is used for public access. They use a single IP (using IP Failover) to connect between them and to allow for a graceful failover. NFS is therefore over a public connection and not under any private network (it was before the upgrade, were the problem still existed). The firewall was configured and tested thoroughly but I disabled it for a while to see if the problem still occurred, and it did. From my knowledge the hosting provider isn't blocking or limiting the connection between either the servers and the public domain (at least under a given bandwidth consumption threshold that hasn't been reached yet). Hope this helps figuring out the problem. EDIT 2: Relevant software versions: CentOS 2.6.32-279.9.1.el6.x86_64 nfs-utils-1.2.3-26.el6.x86_64 nfs-utils-lib-1.1.5-4.el6.x86_64 gfs2-utils-3.0.12.1-32.el6_3.1.x86_64 kmod-drbd84-8.4.2-1.el6_3.elrepo.x86_64 drbd84-utils-8.4.2-1.el6.elrepo.x86_64 DRBD configuration on storage servers: #/etc/drbd.d/storage.res resource storage { protocol C; on <server1 fqdn> { device /dev/drbd0; disk /dev/vg_storage/LV_replicated; address <server1 ip>:7788; meta-disk internal; } on <server2 fqdn> { device /dev/drbd0; disk /dev/vg_storage/LV_replicated; address <server2 ip>:7788; meta-disk internal; } } NFS Configuration in storage servers: #/etc/sysconfig/nfs RPCNFSDCOUNT=32 STATD_PORT=10002 STATD_OUTGOING_PORT=10003 MOUNTD_PORT=10004 RQUOTAD_PORT=10005 LOCKD_UDPPORT=30001 LOCKD_TCPPORT=30001 (can there be any conflict in using the same port for both LOCKD_UDPPORT and LOCKD_TCPPORT?) GFS2 configuration: # gfs2_tool gettune <mountpoint> incore_log_blocks = 1024 log_flush_secs = 60 quota_warn_period = 10 quota_quantum = 60 max_readahead = 262144 complain_secs = 10 statfs_slow = 0 quota_simul_sync = 64 statfs_quantum = 30 quota_scale = 1.0000 (1, 1) new_files_jdata = 0 Storage network environment: eth0 Link encap:Ethernet HWaddr <mac address> inet addr:<ip address> Bcast:<bcast address> Mask:<ip mask> inet6 addr: <ip address> Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:957025127 errors:0 dropped:0 overruns:0 frame:0 TX packets:1473338731 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:2630984979622 (2.3 TiB) TX bytes:1648430431523 (1.4 TiB) eth0:0 Link encap:Ethernet HWaddr <mac address> inet addr:<ip failover address> Bcast:<bcast address> Mask:<ip mask> UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 The IP addresses are statically assigned with the given network configurations: DEVICE="eth0" BOOTPROTO="static" HWADDR=<mac address> ONBOOT="yes" TYPE="Ethernet" IPADDR=<ip address> NETMASK=<net mask> and DEVICE="eth0:0" BOOTPROTO="static" HWADDR=<mac address> IPADDR=<ip failover> NETMASK=<net mask> ONBOOT="yes" BROADCAST=<bcast address> Hosts file to allow for a graceful NFS failover in conjunction with NFS option fsid=25 set on both storage servers: #/etc/hosts <storage ip failover address> active.storage.vlan <webserver ip failover address> active.service.vlan As you can see, packet errors are down to 0. I've also ran ping for a long time without any packet loss. MTU size is the normal 1500. As there is no VLan by now, this is the MTU used to communicate between servers. The webservers' network environment is similar. One thing I forgot to mention is that the storage servers handle ~200GB of new files each day through the NFS connection, which is a key point for me to think this is some kind of heavy load problem with either NFS or GFS2. If you need further configuration details please tell me. EDIT 3: Earlier today we had a major filesystem crash on the storage server. I couldn't get the details of the crash right away because the server stop responding. After the reboot, I noticed the filesystem was extremely slow, and I was not being able to serve a single file through either NFS or httpd, perhaps due to cache warming or so. Nevertheless, I've been monitoring the server closely and the following error came up in dmesg. The source of the problem is clearly GFS, which is waiting for a lock and ends up starving after a while. INFO: task nfsd:3029 blocked for more than 120 seconds. "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message. nfsd D 0000000000000000 0 3029 2 0x00000080 ffff8803814f79e0 0000000000000046 0000000000000000 ffffffff8109213f ffff880434c5e148 ffff880624508d88 ffff8803814f7960 ffffffffa037253f ffff8803815c1098 ffff8803814f7fd8 000000000000fb88 ffff8803815c1098 Call Trace: [<ffffffff8109213f>] ? wake_up_bit+0x2f/0x40 [<ffffffffa037253f>] ? gfs2_holder_wake+0x1f/0x30 [gfs2] [<ffffffff814ff42e>] __mutex_lock_slowpath+0x13e/0x180 [<ffffffff814ff2cb>] mutex_lock+0x2b/0x50 [<ffffffffa0379f21>] gfs2_log_reserve+0x51/0x190 [gfs2] [<ffffffffa0390da2>] gfs2_trans_begin+0x112/0x1d0 [gfs2] [<ffffffffa0369b05>] ? gfs2_dir_check+0x35/0xe0 [gfs2] [<ffffffffa0377943>] gfs2_createi+0x1a3/0xaa0 [gfs2] [<ffffffff8121aab1>] ? avc_has_perm+0x71/0x90 [<ffffffffa0383d1e>] gfs2_create+0x7e/0x1a0 [gfs2] [<ffffffffa037783f>] ? gfs2_createi+0x9f/0xaa0 [gfs2] [<ffffffff81188cf4>] vfs_create+0xb4/0xe0 [<ffffffffa04217d6>] nfsd_create_v3+0x366/0x4c0 [nfsd] [<ffffffffa0429703>] nfsd3_proc_create+0x123/0x1b0 [nfsd] [<ffffffffa041a43e>] nfsd_dispatch+0xfe/0x240 [nfsd] [<ffffffffa025a5d4>] svc_process_common+0x344/0x640 [sunrpc] [<ffffffff810602a0>] ? default_wake_function+0x0/0x20 [<ffffffffa025ac10>] svc_process+0x110/0x160 [sunrpc] [<ffffffffa041ab62>] nfsd+0xc2/0x160 [nfsd] [<ffffffffa041aaa0>] ? nfsd+0x0/0x160 [nfsd] [<ffffffff81091de6>] kthread+0x96/0xa0 [<ffffffff8100c14a>] child_rip+0xa/0x20 [<ffffffff81091d50>] ? kthread+0x0/0xa0 [<ffffffff8100c140>] ? child_rip+0x0/0x20

    Read the article

  • SPARC T4-4 Beats 8-CPU IBM POWER7 on TPC-H @3000GB Benchmark

    - by Brian
    Oracle's SPARC T4-4 server delivered a world record TPC-H @3000GB benchmark result for systems with four processors. This result beats eight processor results from IBM (POWER7) and HP (x86). The SPARC T4-4 server also delivered better performance per core than these eight processor systems from IBM and HP. Comparisons below are based upon system to system comparisons, highlighting Oracle's complete software and hardware solution. This database world record result used Oracle's Sun Storage 2540-M2 arrays (rotating disk) connected to a SPARC T4-4 server running Oracle Solaris 11 and Oracle Database 11g Release 2 demonstrating the power of Oracle's integrated hardware and software solution. The SPARC T4-4 server based configuration achieved a TPC-H scale factor 3000 world record for four processor systems of 205,792 QphH@3000GB with price/performance of $4.10/QphH@3000GB. The SPARC T4-4 server with four SPARC T4 processors (total of 32 cores) is 7% faster than the IBM Power 780 server with eight POWER7 processors (total of 32 cores) on the TPC-H @3000GB benchmark. The SPARC T4-4 server is 36% better in price performance compared to the IBM Power 780 server on the TPC-H @3000GB Benchmark. The SPARC T4-4 server is 29% faster than the IBM Power 780 for data loading. The SPARC T4-4 server is up to 3.4 times faster than the IBM Power 780 server for the Refresh Function. The SPARC T4-4 server with four SPARC T4 processors is 27% faster than the HP ProLiant DL980 G7 server with eight x86 processors on the TPC-H @3000GB benchmark. The SPARC T4-4 server is 52% faster than the HP ProLiant DL980 G7 server for data loading. The SPARC T4-4 server is up to 3.2 times faster than the HP ProLiant DL980 G7 for the Refresh Function. The SPARC T4-4 server achieved a peak IO rate from the Oracle database of 17 GB/sec. This rate was independent of the storage used, as demonstrated by the TPC-H @3000TB benchmark which used twelve Sun Storage 2540-M2 arrays (rotating disk) and the TPC-H @1000TB benchmark which used four Sun Storage F5100 Flash Array devices (flash storage). [*] The SPARC T4-4 server showed linear scaling from TPC-H @1000GB to TPC-H @3000GB. This demonstrates that the SPARC T4-4 server can handle the increasingly larger databases required of DSS systems. [*] The SPARC T4-4 server benchmark results demonstrate a complete solution of building Decision Support Systems including data loading, business questions and refreshing data. Each phase usually has a time constraint and the SPARC T4-4 server shows superior performance during each phase. [*] The TPC believes that comparisons of results published with different scale factors are misleading and discourages such comparisons. Performance Landscape The table lists the leading TPC-H @3000GB results for non-clustered systems. TPC-H @3000GB, Non-Clustered Systems System Processor P/C/T – Memory Composite(QphH) $/perf($/QphH) Power(QppH) Throughput(QthH) Database Available SPARC Enterprise M9000 3.0 GHz SPARC64 VII+ 64/256/256 – 1024 GB 386,478.3 $18.19 316,835.8 471,428.6 Oracle 11g R2 09/22/11 SPARC T4-4 3.0 GHz SPARC T4 4/32/256 – 1024 GB 205,792.0 $4.10 190,325.1 222,515.9 Oracle 11g R2 05/31/12 SPARC Enterprise M9000 2.88 GHz SPARC64 VII 32/128/256 – 512 GB 198,907.5 $15.27 182,350.7 216,967.7 Oracle 11g R2 12/09/10 IBM Power 780 4.1 GHz POWER7 8/32/128 – 1024 GB 192,001.1 $6.37 210,368.4 175,237.4 Sybase 15.4 11/30/11 HP ProLiant DL980 G7 2.27 GHz Intel Xeon X7560 8/64/128 – 512 GB 162,601.7 $2.68 185,297.7 142,685.6 SQL Server 2008 10/13/10 P/C/T = Processors, Cores, Threads QphH = the Composite Metric (bigger is better) $/QphH = the Price/Performance metric in USD (smaller is better) QppH = the Power Numerical Quantity QthH = the Throughput Numerical Quantity The following table lists data load times and refresh function times during the power run. TPC-H @3000GB, Non-Clustered Systems Database Load & Database Refresh System Processor Data Loading(h:m:s) T4Advan RF1(sec) T4Advan RF2(sec) T4Advan SPARC T4-4 3.0 GHz SPARC T4 04:08:29 1.0x 67.1 1.0x 39.5 1.0x IBM Power 780 4.1 GHz POWER7 05:51:50 1.5x 147.3 2.2x 133.2 3.4x HP ProLiant DL980 G7 2.27 GHz Intel Xeon X7560 08:35:17 2.1x 173.0 2.6x 126.3 3.2x Data Loading = database load time RF1 = power test first refresh transaction RF2 = power test second refresh transaction T4 Advan = the ratio of time to T4 time Complete benchmark results found at the TPC benchmark website http://www.tpc.org. Configuration Summary and Results Hardware Configuration: SPARC T4-4 server 4 x SPARC T4 3.0 GHz processors (total of 32 cores, 128 threads) 1024 GB memory 8 x internal SAS (8 x 300 GB) disk drives External Storage: 12 x Sun Storage 2540-M2 array storage, each with 12 x 15K RPM 300 GB drives, 2 controllers, 2 GB cache Software Configuration: Oracle Solaris 11 11/11 Oracle Database 11g Release 2 Enterprise Edition Audited Results: Database Size: 3000 GB (Scale Factor 3000) TPC-H Composite: 205,792.0 QphH@3000GB Price/performance: $4.10/QphH@3000GB Available: 05/31/2012 Total 3 year Cost: $843,656 TPC-H Power: 190,325.1 TPC-H Throughput: 222,515.9 Database Load Time: 4:08:29 Benchmark Description The TPC-H benchmark is a performance benchmark established by the Transaction Processing Council (TPC) to demonstrate Data Warehousing/Decision Support Systems (DSS). TPC-H measurements are produced for customers to evaluate the performance of various DSS systems. These queries and updates are executed against a standard database under controlled conditions. Performance projections and comparisons between different TPC-H Database sizes (100GB, 300GB, 1000GB, 3000GB, 10000GB, 30000GB and 100000GB) are not allowed by the TPC. TPC-H is a data warehousing-oriented, non-industry-specific benchmark that consists of a large number of complex queries typical of decision support applications. It also includes some insert and delete activity that is intended to simulate loading and purging data from a warehouse. TPC-H measures the combined performance of a particular database manager on a specific computer system. The main performance metric reported by TPC-H is called the TPC-H Composite Query-per-Hour Performance Metric (QphH@SF, where SF is the number of GB of raw data, referred to as the scale factor). QphH@SF is intended to summarize the ability of the system to process queries in both single and multiple user modes. The benchmark requires reporting of price/performance, which is the ratio of the total HW/SW cost plus 3 years maintenance to the QphH. A secondary metric is the storage efficiency, which is the ratio of total configured disk space in GB to the scale factor. Key Points and Best Practices Twelve Sun Storage 2540-M2 arrays were used for the benchmark. Each Sun Storage 2540-M2 array contains 12 15K RPM drives and is connected to a single dual port 8Gb FC HBA using 2 ports. Each Sun Storage 2540-M2 array showed 1.5 GB/sec for sequential read operations and showed linear scaling, achieving 18 GB/sec with twelve Sun Storage 2540-M2 arrays. These were stand alone IO tests. The peak IO rate measured from the Oracle database was 17 GB/sec. Oracle Solaris 11 11/11 required very little system tuning. Some vendors try to make the point that storage ratios are of customer concern. However, storage ratio size has more to do with disk layout and the increasing capacities of disks – so this is not an important metric in which to compare systems. The SPARC T4-4 server and Oracle Solaris efficiently managed the system load of over one thousand Oracle Database parallel processes. Six Sun Storage 2540-M2 arrays were mirrored to another six Sun Storage 2540-M2 arrays on which all of the Oracle database files were placed. IO performance was high and balanced across all the arrays. The TPC-H Refresh Function (RF) simulates periodical refresh portion of Data Warehouse by adding new sales and deleting old sales data. Parallel DML (parallel insert and delete in this case) and database log performance are a key for this function and the SPARC T4-4 server outperformed both the IBM POWER7 server and HP ProLiant DL980 G7 server. (See the RF columns above.) See Also Transaction Processing Performance Council (TPC) Home Page Ideas International Benchmark Page SPARC T4-4 Server oracle.com OTN Oracle Solaris oracle.com OTN Oracle Database 11g Release 2 Enterprise Edition oracle.com OTN Sun Storage 2540-M2 Array oracle.com OTN Disclosure Statement TPC-H, QphH, $/QphH are trademarks of Transaction Processing Performance Council (TPC). For more information, see www.tpc.org. SPARC T4-4 205,792.0 QphH@3000GB, $4.10/QphH@3000GB, available 5/31/12, 4 processors, 32 cores, 256 threads; IBM Power 780 QphH@3000GB, 192,001.1 QphH@3000GB, $6.37/QphH@3000GB, available 11/30/11, 8 processors, 32 cores, 128 threads; HP ProLiant DL980 G7 162,601.7 QphH@3000GB, $2.68/QphH@3000GB available 10/13/10, 8 processors, 64 cores, 128 threads.

    Read the article

  • Thread placement policies on NUMA systems - update

    - by Dave
    In a prior blog entry I noted that Solaris used a "maximum dispersal" placement policy to assign nascent threads to their initial processors. The general idea is that threads should be placed as far away from each other as possible in the resource topology in order to reduce resource contention between concurrently running threads. This policy assumes that resource contention -- pipelines, memory channel contention, destructive interference in the shared caches, etc -- will likely outweigh (a) any potential communication benefits we might achieve by packing our threads more densely onto a subset of the NUMA nodes, and (b) benefits of NUMA affinity between memory allocated by one thread and accessed by other threads. We want our threads spread widely over the system and not packed together. Conceptually, when placing a new thread, the kernel picks the least loaded node NUMA node (the node with lowest aggregate load average), and then the least loaded core on that node, etc. Furthermore, the kernel places threads onto resources -- sockets, cores, pipelines, etc -- without regard to the thread's process membership. That is, initial placement is process-agnostic. Keep reading, though. This description is incorrect. On Solaris 10 on a SPARC T5440 with 4 x T2+ NUMA nodes, if the system is otherwise unloaded and we launch a process that creates 20 compute-bound concurrent threads, then typically we'll see a perfect balance with 5 threads on each node. We see similar behavior on an 8-node x86 x4800 system, where each node has 8 cores and each core is 2-way hyperthreaded. So far so good; this behavior seems in agreement with the policy I described in the 1st paragraph. I recently tried the same experiment on a 4-node T4-4 running Solaris 11. Both the T5440 and T4-4 are 4-node systems that expose 256 logical thread contexts. To my surprise, all 20 threads were placed onto just one NUMA node while the other 3 nodes remained completely idle. I checked the usual suspects such as processor sets inadvertently left around by colleagues, processors left offline, and power management policies, but the system was configured normally. I then launched multiple concurrent instances of the process, and, interestingly, all the threads from the 1st process landed on one node, all the threads from the 2nd process landed on another node, and so on. This happened even if I interleaved thread creating between the processes, so I was relatively sure the effect didn't related to thread creation time, but rather that placement was a function of process membership. I this point I consulted the Solaris sources and talked with folks in the Solaris group. The new Solaris 11 behavior is intentional. The kernel is no longer using a simple maximum dispersal policy, and thread placement is process membership-aware. Now, even if other nodes are completely unloaded, the kernel will still try to pack new threads onto the home lgroup (socket) of the primordial thread until the load average of that node reaches 50%, after which it will pick the next least loaded node as the process's new favorite node for placement. On the T4-4 we have 64 logical thread contexts (strands) per socket (lgroup), so if we launch 48 concurrent threads we will find 32 placed on one node and 16 on some other node. If we launch 64 threads we'll find 32 and 32. That means we can end up with our threads clustered on a small subset of the nodes in a way that's quite different that what we've seen on Solaris 10. So we have a policy that allows process-aware packing but reverts to spreading threads onto other nodes if a node becomes too saturated. It turns out this policy was enabled in Solaris 10, but certain bugs suppressed the mixed packing/spreading behavior. There are configuration variables in /etc/system that allow us to dial the affinity between nascent threads and their primordial thread up and down: see lgrp_expand_proc_thresh, specifically. In the OpenSolaris source code the key routine is mpo_update_tunables(). This method reads the /etc/system variables and sets up some global variables that will subsequently be used by the dispatcher, which calls lgrp_choose() in lgrp.c to place nascent threads. Lgrp_expand_proc_thresh controls how loaded an lgroup must be before we'll consider homing a process's threads to another lgroup. Tune this value lower to have it spread your process's threads out more. To recap, the 'new' policy is as follows. Threads from the same process are packed onto a subset of the strands of a socket (50% for T-series). Once that socket reaches the 50% threshold the kernel then picks another preferred socket for that process. Threads from unrelated processes are spread across sockets. More precisely, different processes may have different preferred sockets (lgroups). Beware that I've simplified and elided details for the purposes of explication. The truth is in the code. Remarks: It's worth noting that initial thread placement is just that. If there's a gross imbalance between the load on different nodes then the kernel will migrate threads to achieve a better and more even distribution over the set of available nodes. Once a thread runs and gains some affinity for a node, however, it becomes "stickier" under the assumption that the thread has residual cache residency on that node, and that memory allocated by that thread resides on that node given the default "first-touch" page-level NUMA allocation policy. Exactly how the various policies interact and which have precedence under what circumstances could the topic of a future blog entry. The scheduler is work-conserving. The x4800 mentioned above is an interesting system. Each of the 8 sockets houses an Intel 7500-series processor. Each processor has 3 coherent QPI links and the system is arranged as a glueless 8-socket twisted ladder "mobius" topology. Nodes are either 1 or 2 hops distant over the QPI links. As an aside the mapping of logical CPUIDs to physical resources is rather interesting on Solaris/x4800. On SPARC/Solaris the CPUID layout is strictly geographic, with the highest order bits identifying the socket, the next lower bits identifying the core within that socket, following by the pipeline (if present) and finally the logical thread context ("strand") on the core. But on Solaris on the x4800 the CPUID layout is as follows. [6:6] identifies the hyperthread on a core; bits [5:3] identify the socket, or package in Intel terminology; bits [2:0] identify the core within a socket. Such low-level details should be of interest only if you're binding threads -- a bad idea, the kernel typically handles placement best -- or if you're writing NUMA-aware code that's aware of the ambient placement and makes decisions accordingly. Solaris introduced the so-called critical-threads mechanism, which is expressed by putting a thread into the FX scheduling class at priority 60. The critical-threads mechanism applies to placement on cores, not on sockets, however. That is, it's an intra-socket policy, not an inter-socket policy. Solaris 11 introduces the Power Aware Dispatcher (PAD) which packs threads instead of spreading them out in an attempt to be able to keep sockets or cores at lower power levels. Maximum dispersal may be good for performance but is anathema to power management. PAD is off by default, but power management polices constitute yet another confounding factor with respect to scheduling and dispatching. If your threads communicate heavily -- one thread reads cache lines last written by some other thread -- then the new dense packing policy may improve performance by reducing traffic on the coherent interconnect. On the other hand if your threads in your process communicate rarely, then it's possible the new packing policy might result on contention on shared computing resources. Unfortunately there's no simple litmus test that says whether packing or spreading is optimal in a given situation. The answer varies by system load, application, number of threads, and platform hardware characteristics. Currently we don't have the necessary tools and sensoria to decide at runtime, so we're reduced to an empirical approach where we run trials and try to decide on a placement policy. The situation is quite frustrating. Relatedly, it's often hard to determine just the right level of concurrency to optimize throughput. (Understanding constructive vs destructive interference in the shared caches would be a good start. We could augment the lines with a small tag field indicating which strand last installed or accessed a line. Given that, we could augment the CPU with performance counters for misses where a thread evicts a line it installed vs misses where a thread displaces a line installed by some other thread.)

    Read the article

  • External usb 3.0 hard drive is not recognised when plugged into usb 3 port (ubuntu natty 64 bit).

    - by kimangroo
    I have an Iomega Prestige Portable External Hard Drive 1TB USB 3.0. It works fine on windows 7 as a usb 3.0 drive. It isn't detected on ubuntu natty 64bit, 2.6.38-8-generic. fdisk -l cannot see it at all: Disk /dev/sda: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x1bed746b Device Boot Start End Blocks Id System /dev/sda1 1 1689 13560832 27 Unknown /dev/sda2 * 1689 1702 102400 7 HPFS/NTFS /dev/sda3 1702 19978 146805760 7 HPFS/NTFS /dev/sda4 19978 60802 327914497 5 Extended /dev/sda5 25555 60802 283120640 7 HPFS/NTFS /dev/sda6 19978 23909 31571968 83 Linux /dev/sda7 23909 25555 13218816 82 Linux swap / Solaris Partition table entries are not in disk order lsusb can see it: Bus 003 Device 003: ID 059b:0070 Iomega Corp. Bus 003 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 002 Device 004: ID 05fe:0011 Chic Technology Corp. Browser Mouse Bus 002 Device 003: ID 0a12:0001 Cambridge Silicon Radio, Ltd Bluetooth Dongle (HCI mode) Bus 002 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 001 Device 005: ID 0489:e00f Foxconn / Hon Hai Bus 001 Device 004: ID 0c45:64b5 Microdia Bus 001 Device 003: ID 08ff:168f AuthenTec, Inc. Bus 001 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub And dmesg | grep -i xhci (I may have unplugged the drive and plugged it back in again after booting): [ 1.659060] pci 0000:04:00.0: xHCI HW did not halt within 2000 usec status = 0x0 [ 11.484971] xhci_hcd 0000:04:00.0: PCI INT A -> GSI 18 (level, low) -> IRQ 18 [ 11.484997] xhci_hcd 0000:04:00.0: setting latency timer to 64 [ 11.485002] xhci_hcd 0000:04:00.0: xHCI Host Controller [ 11.485064] xhci_hcd 0000:04:00.0: new USB bus registered, assigned bus number 3 [ 11.636149] xhci_hcd 0000:04:00.0: irq 18, io mem 0xc5400000 [ 11.636241] xhci_hcd 0000:04:00.0: irq 43 for MSI/MSI-X [ 11.636246] xhci_hcd 0000:04:00.0: irq 44 for MSI/MSI-X [ 11.636251] xhci_hcd 0000:04:00.0: irq 45 for MSI/MSI-X [ 11.636256] xhci_hcd 0000:04:00.0: irq 46 for MSI/MSI-X [ 11.636261] xhci_hcd 0000:04:00.0: irq 47 for MSI/MSI-X [ 11.639654] xHCI xhci_add_endpoint called for root hub [ 11.639655] xHCI xhci_check_bandwidth called for root hub [ 11.956366] usb 3-1: new SuperSpeed USB device using xhci_hcd and address 2 [ 12.001073] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 12.007059] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 12.012932] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 12.018922] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 12.049139] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 12.056754] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 12.131607] xhci_hcd 0000:04:00.0: WARN no SS endpoint bMaxBurst [ 12.179717] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 12.686876] xhci_hcd 0000:04:00.0: WARN: babble error on endpoint [ 12.687058] xhci_hcd 0000:04:00.0: WARN Set TR Deq Ptr cmd invalid because of stream ID configuration [ 12.687152] xhci_hcd 0000:04:00.0: ERROR Transfer event for disabled endpoint or incorrect stream ring [ 43.330737] usb 3-1: reset SuperSpeed USB device using xhci_hcd and address 2 [ 43.422579] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 43.422658] xhci_hcd 0000:04:00.0: xHCI xhci_drop_endpoint called with disabled ep ffff88014669af00 [ 43.422665] xhci_hcd 0000:04:00.0: xHCI xhci_drop_endpoint called with disabled ep ffff88014669af40 [ 43.422671] xhci_hcd 0000:04:00.0: xHCI xhci_drop_endpoint called with disabled ep ffff88014669af80 [ 43.422677] xhci_hcd 0000:04:00.0: xHCI xhci_drop_endpoint called with disabled ep ffff88014669afc0 [ 43.531159] xhci_hcd 0000:04:00.0: WARN no SS endpoint bMaxBurst [ 125.160248] xhci_hcd 0000:04:00.0: WARN no SS endpoint bMaxBurst [ 903.766466] usb 3-1: new SuperSpeed USB device using xhci_hcd and address 3 [ 903.807789] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 903.813530] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 903.819400] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 903.825104] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 903.855067] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 903.862314] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 903.862597] xhci_hcd 0000:04:00.0: WARN no SS endpoint bMaxBurst [ 903.913211] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 904.424416] xhci_hcd 0000:04:00.0: WARN: babble error on endpoint [ 904.424599] xhci_hcd 0000:04:00.0: WARN Set TR Deq Ptr cmd invalid because of stream ID configuration [ 904.424700] xhci_hcd 0000:04:00.0: ERROR Transfer event for disabled endpoint or incorrect stream ring [ 935.139021] usb 3-1: reset SuperSpeed USB device using xhci_hcd and address 3 [ 935.226075] xhci_hcd 0000:04:00.0: WARN: short transfer on control ep [ 935.226140] xhci_hcd 0000:04:00.0: xHCI xhci_drop_endpoint called with disabled ep ffff880148186b00 [ 935.226148] xhci_hcd 0000:04:00.0: xHCI xhci_drop_endpoint called with disabled ep ffff880148186b40 [ 935.226153] xhci_hcd 0000:04:00.0: xHCI xhci_drop_endpoint called with disabled ep ffff880148186b80 [ 935.226159] xhci_hcd 0000:04:00.0: xHCI xhci_drop_endpoint called with disabled ep ffff880148186bc0 [ 935.343339] xhci_hcd 0000:04:00.0: WARN no SS endpoint bMaxBurst I thought it might be that the firmware wasn't compatible with linux or something, but when booting a live image of partedmagic, (2.6.38.4-pmagic), the drive was detected fine, I could mount it and got usb 3.0 speeds (at least they double the speeds I got from plugging same drive in usb 2 ports). dmesg in partedmagic did say something about no SuperSpeed endpoint which was an error I saw in a previous dmesg of ubuntu: Jun 27 15:49:02 (none) user.info kernel: [ 2.978743] xhci_hcd 0000:04:00.0: PCI INT A -> GSI 18 (level, low) -> IRQ 18 Jun 27 15:49:02 (none) user.debug kernel: [ 2.978771] xhci_hcd 0000:04:00.0: setting latency timer to 64 Jun 27 15:49:02 (none) user.info kernel: [ 2.978781] xhci_hcd 0000:04:00.0: xHCI Host Controller Jun 27 15:49:02 (none) user.info kernel: [ 2.978856] xhci_hcd 0000:04:00.0: new USB bus registered, assigned bus number 3 Jun 27 15:49:02 (none) user.info kernel: [ 3.089458] xhci_hcd 0000:04:00.0: irq 18, io mem 0xc5400000 Jun 27 15:49:02 (none) user.debug kernel: [ 3.089541] xhci_hcd 0000:04:00.0: irq 42 for MSI/MSI-X Jun 27 15:49:02 (none) user.debug kernel: [ 3.089544] xhci_hcd 0000:04:00.0: irq 43 for MSI/MSI-X Jun 27 15:49:02 (none) user.debug kernel: [ 3.089546] xhci_hcd 0000:04:00.0: irq 44 for MSI/MSI-X Jun 27 15:49:02 (none) user.debug kernel: [ 3.089548] xhci_hcd 0000:04:00.0: irq 45 for MSI/MSI-X Jun 27 15:49:02 (none) user.debug kernel: [ 3.089550] xhci_hcd 0000:04:00.0: irq 46 for MSI/MSI-X Jun 27 15:49:02 (none) user.warn kernel: [ 3.092857] usb usb3: No SuperSpeed endpoint companion for config 1 interface 0 altsetting 0 ep 129: using minimum values Jun 27 15:49:02 (none) user.info kernel: [ 3.092864] usb usb3: New USB device found, idVendor=1d6b, idProduct=0003 Jun 27 15:49:02 (none) user.info kernel: [ 3.092866] usb usb3: New USB device strings: Mfr=3, Product=2, SerialNumber=1 Jun 27 15:49:02 (none) user.info kernel: [ 3.092867] usb usb3: Product: xHCI Host Controller Jun 27 15:49:02 (none) user.info kernel: [ 3.092869] usb usb3: Manufacturer: Linux 2.6.38.4-pmagic xhci_hcd Jun 27 15:49:02 (none) user.info kernel: [ 3.092870] usb usb3: SerialNumber: 0000:04:00.0 Jun 27 15:49:02 (none) user.debug kernel: [ 3.092961] xHCI xhci_add_endpoint called for root hub Jun 27 15:49:02 (none) user.debug kernel: [ 3.092963] xHCI xhci_check_bandwidth called for root hub Well I have no idea what's going wrong, and I haven't had much luck from google and the forums so far. A number of unanswered threads with people with similar error messages and problems only. Hopefully someone here can help or point me in the right direction?!

    Read the article

  • NVIDIA x server - "sudo nvidia config" does not generate a working 'xorg.config'

    - by Mike
    I am over 18 hours deep on this challenge. I got to this point and am stuck. very stuck. Maybe you can figure it out? Ubuntu Version 12.04 LTS with all the updates installed. Problem: The default settings in "etc/X11/xorg.conf" that are generated by the "nvidia-xconfig" tool, do not allow the NVIDIA x server to connect to the driver in my "System Settings Additional Driver window". (that's how I understand it. Lots of information below). Symptoms of Problem "System Settings Additional Driver" window has drivers, but the nvidia x server cannot connect/utilize any of the 4 drivers. the drivers are activated, but not in use. When I go to "System Tools Administration NVIDIA x server settings" I get an error that basically tells me to create a default file to initialize the NVIDIA X server (screen shot below). This is the messages the terminal gives after running a "sudo nvidia-xconfig" command for the first time. It seems that the generated file by the tool i just ran is generating a bad/unusable file: If I run the "sudo nvidia-xconfig" command again, I wont get an error the second time. However when I reboot, the default file that is generated (etc/X11/xorg.conf) simply puts the screen resolution at 800 x 600 (or something big like that). When I try to go to NVIDIA x server settings I am greeted with the same screen as the screen shot as in symptom 2 (no option to change the resolution). If I try to go to "system settings display" there are no other resolutions to choose from. At this point I must delete the newly minted "xorg.conf" and reinstate the original in its place. Here are the contents of the "xorg.conf" that is generated first (the one missing required information): # nvidia-xconfig: X configuration file generated by nvidia-xconfig # nvidia-xconfig: version 304.88 (buildmeister@swio-display-x86-rhel47-06) Wed Mar 27 15:32:58 PDT 2013 Section "ServerLayout" Identifier "Layout0" Screen 0 "Screen0" InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" Identifier "Monitor0" VendorName "Unknown" ModelName "Unknown" HorizSync 28.0 - 33.0 VertRefresh 43.0 - 72.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" EndSection Section "Screen" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 SubSection "Display" Depth 24 EndSubSection EndSection Hardware: I ran the "lspci|grep VGA". There results are: 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09) 01:00.0 VGA compatible controller: NVIDIA Corporation GF108 [Quadro 1000M] (rev a1) More Hardware info: Ram: 16GB CPU: Intel Core i7-2720QM @2.2GHz * 8 Other: 64 bit. This is a triple boot computer and not a VM. Attempts With Not Success on My End: 1) Tried to append the "xorg.conf" with what I perceive is missing information and obviously it didn't fly. 2) All the other stuff I tried got me to this point. 3) See if this link is helpful to you (I barely get it, but i get enough knowing that a smarter person might find this useful): http://manpages.ubuntu.com/manpages/lucid/man1/nvidia-xconfig.1.html 4) I am completely new to Linux (40 hours over past week), but not to programming. However I am very serious about changing over to Linux. When you respond (I hope someone responds...) please respond in a way that a person new to Linux can understand. 5) By the way, the reason I am in this mess is because I MUST have a second monitor running from my laptop, and "System Settings Display" doesn't recognize my second display. I know it is possible to make the second display work in my system, because when I boot from the install CD, I perform work on the native laptop monitor, but the second monitor shows a purple screen with Ubuntu in the middle, so I know the VGA port is sending a signal out. If this is too much for you to tackle please suggest an alternative method to get a second display. I don't want to go to windows but I cannot have a single display. I am really fudged here. I hope some smart person can help. Thanks in advance. Mike. **********************EDIT #1********************** More Details About Graphics Card I was asked "which brand of nvidia-card do you have exactly?" Here is what I did to provide more info (maybe relevant, maybe not, but here is everything): 1) Took my Lenovo W520 right apart to see if there is an identifier on the actual card. However I realized that if I get deep enough to take a look, the laptop "won't like it". so I put it back together. Figuring out the card this way is not an option for me right now. 2) (My computer is triple boot) I logged into Win7 and ran 'dxdiag' command. here is the screen shot: 3) I tried to look on the lenovo website for more details... but no luck. I took a look at my receipts and here is info form receipt: System Unit: W520 NVIDIA Quadro 1000M 2GB 4) In win7 I went to the NVIDIA website and used the option to have my card 'scanned' by a Java applet to determine the latest update for my card. I tried the same with Ubuntu but I can't get the applet to run. Here is the recommended driver from from the NVIDIA Applet for my card for Win7 (I hope this shines some light on the specifics of the card): Quadro/NVS/Tesla/GRID Desktop Driver Release R319 Version: 320.00 WHQL Release Date: 3.5.2013 5) Also I went on the NVIDIA driver search and looked through every possible combination of product type + product series + product to find all the combinations that yield a 1000M card. My card is: Product Type: Quadro Product Series: Quadro Series (Notebooks) Product: 1000M ***********************EDIT #2******************* Additional Symptoms Another question that generated more symptoms I previously didn't mention was: "After generating xorg.conf by nvidia-xconfig, go to additional drivers, do you see nvidia-304?" 1) I took a screen shot of the "additional drivers" right after generating xorg.conf by nvidia-xconfig. Here it is: 2) Then I did a reboot. Now Ubuntu is 600 x 800 resolution. When I logged in after the computer came up I got an error (which I always get after generating xorg.conf by nvidia-xconfig and rebooting) 3) To finally answer the question - No. There is no "NVIDIA-304" driver. Screen shot of additional drivers after generating xorg.conf by nvidia-xconfig and rebooting : At this point I revert to the original xorg.conf and delete the xorg.conf generated by Nvidia.

    Read the article

  • NUMA-aware placement of communication variables

    - by Dave
    For classic NUMA-aware programming I'm typically most concerned about simple cold, capacity and compulsory misses and whether we can satisfy the miss by locally connected memory or whether we have to pull the line from its home node over the coherent interconnect -- we'd like to minimize channel contention and conserve interconnect bandwidth. That is, for this style of programming we're quite aware of where memory is homed relative to the threads that will be accessing it. Ideally, a page is collocated on the node with the thread that's expected to most frequently access the page, as simple misses on the page can be satisfied without resorting to transferring the line over the interconnect. The default "first touch" NUMA page placement policy tends to work reasonable well in this regard. When a virtual page is first accessed, the operating system will attempt to provision and map that virtual page to a physical page allocated from the node where the accessing thread is running. It's worth noting that the node-level memory interleaving granularity is usually a multiple of the page size, so we can say that a given page P resides on some node N. That is, the memory underlying a page resides on just one node. But when thinking about accesses to heavily-written communication variables we normally consider what caches the lines underlying such variables might be resident in, and in what states. We want to minimize coherence misses and cache probe activity and interconnect traffic in general. I don't usually give much thought to the location of the home NUMA node underlying such highly shared variables. On a SPARC T5440, for instance, which consists of 4 T2+ processors connected by a central coherence hub, the home node and placement of heavily accessed communication variables has very little impact on performance. The variables are frequently accessed so likely in M-state in some cache, and the location of the home node is of little consequence because a requester can use cache-to-cache transfers to get the line. Or at least that's what I thought. Recently, though, I was exploring a simple shared memory point-to-point communication model where a client writes a request into a request mailbox and then busy-waits on a response variable. It's a simple example of delegation based on message passing. The server polls the request mailbox, and having fetched a new request value, performs some operation and then writes a reply value into the response variable. As noted above, on a T5440 performance is insensitive to the placement of the communication variables -- the request and response mailbox words. But on a Sun/Oracle X4800 I noticed that was not the case and that NUMA placement of the communication variables was actually quite important. For background an X4800 system consists of 8 Intel X7560 Xeons . Each package (socket) has 8 cores with 2 contexts per core, so the system is 8x8x2. Each package is also a NUMA node and has locally attached memory. Every package has 3 point-to-point QPI links for cache coherence, and the system is configured with a twisted ladder "mobius" topology. The cache coherence fabric is glueless -- there's not central arbiter or coherence hub. The maximum distance between any two nodes is just 2 hops over the QPI links. For any given node, 3 other nodes are 1 hop distant and the remaining 4 nodes are 2 hops distant. Using a single request (client) thread and a single response (server) thread, a benchmark harness explored all permutations of NUMA placement for the two threads and the two communication variables, measuring the average round-trip-time and throughput rate between the client and server. In this benchmark the server simply acts as a simple transponder, writing the request value plus 1 back into the reply field, so there's no particular computation phase and we're only measuring communication overheads. In addition to varying the placement of communication variables over pairs of nodes, we also explored variations where both variables were placed on one page (and thus on one node) -- either on the same cache line or different cache lines -- while varying the node where the variables reside along with the placement of the threads. The key observation was that if the client and server threads were on different nodes, then the best placement of variables was to have the request variable (written by the client and read by the server) reside on the same node as the client thread, and to place the response variable (written by the server and read by the client) on the same node as the server. That is, if you have a variable that's to be written by one thread and read by another, it should be homed with the writer thread. For our simple client-server model that means using split request and response communication variables with unidirectional message flow on a given page. This can yield up to twice the throughput of less favorable placement strategies. Our X4800 uses the QPI 1.0 protocol with source-based snooping. Briefly, when node A needs to probe a cache line it fires off snoop requests to all the nodes in the system. Those recipients then forward their response not to the original requester, but to the home node H of the cache line. H waits for and collects the responses, adjudicates and resolves conflicts and ensures memory-model ordering, and then sends a definitive reply back to the original requester A. If some node B needed to transfer the line to A, it will do so by cache-to-cache transfer and let H know about the disposition of the cache line. A needs to wait for the authoritative response from H. So if a thread on node A wants to write a value to be read by a thread on node B, the latency is dependent on the distances between A, B, and H. We observe the best performance when the written-to variable is co-homed with the writer A. That is, we want H and A to be the same node, as the writer doesn't need the home to respond over the QPI link, as the writer and the home reside on the very same node. With architecturally informed placement of communication variables we eliminate at least one QPI hop from the critical path. Newer Intel processors use the QPI 1.1 coherence protocol with home-based snooping. As noted above, under source-snooping a requester broadcasts snoop requests to all nodes. Those nodes send their response to the home node of the location, which provides memory ordering, reconciles conflicts, etc., and then posts a definitive reply to the requester. In home-based snooping the snoop probe goes directly to the home node and are not broadcast. The home node can consult snoop filters -- if present -- and send out requests to retrieve the line if necessary. The 3rd party owner of the line, if any, can respond either to the home or the original requester (or even to both) according to the protocol policies. There are myriad variations that have been implemented, and unfortunately vendor terminology doesn't always agree between vendors or with the academic taxonomy papers. The key is that home-snooping enables the use of a snoop filter to reduce interconnect traffic. And while home-snooping might have a longer critical path (latency) than source-based snooping, it also may require fewer messages and less overall bandwidth. It'll be interesting to reprise these experiments on a platform with home-based snooping. While collecting data I also noticed that there are placement concerns even in the seemingly trivial case when both threads and both variables reside on a single node. Internally, the cores on each X7560 package are connected by an internal ring. (Actually there are multiple contra-rotating rings). And the last-level on-chip cache (LLC) is partitioned in banks or slices, which with each slice being associated with a core on the ring topology. A hardware hash function associates each physical address with a specific home bank. Thus we face distance and topology concerns even for intra-package communications, although the latencies are not nearly the magnitude we see inter-package. I've not seen such communication distance artifacts on the T2+, where the cache banks are connected to the cores via a high-speed crossbar instead of a ring -- communication latencies seem more regular.

    Read the article

  • GLSL compiler messages from different vendors [on hold]

    - by revers
    I'm writing a GLSL shader editor and I want to parse GLSL compiler messages to make hyperlinks to invalid lines in a shader code. I know that these messages are vendor specific but currently I have access only to AMD's video cards. I want to handle at least NVidia's and Intel's hardware, apart from AMD's. If you have video card from different vendor than AMD, could you please give me the output of following C++ program: #include <GL/glew.h> #include <GL/freeglut.h> #include <iostream> using namespace std; #define STRINGIFY(X) #X static const char* fs = STRINGIFY( out vec4 out_Color; mat4 m; void main() { vec3 v3 = vec3(1.0); vec2 v2 = v3; out_Color = vec4(5.0 * v2.x, 1.0); vec3 k = 3.0; float = 5; } ); static const char* vs = STRINGIFY( in vec3 in_Position; void main() { vec3 v(5); gl_Position = vec4(in_Position, 1.0); } ); void printShaderInfoLog(GLint shader) { int infoLogLen = 0; int charsWritten = 0; GLchar *infoLog; glGetShaderiv(shader, GL_INFO_LOG_LENGTH, &infoLogLen); if (infoLogLen > 0) { infoLog = new GLchar[infoLogLen]; glGetShaderInfoLog(shader, infoLogLen, &charsWritten, infoLog); cout << "Log:\n" << infoLog << endl; delete [] infoLog; } } void printProgramInfoLog(GLint program) { int infoLogLen = 0; int charsWritten = 0; GLchar *infoLog; glGetProgramiv(program, GL_INFO_LOG_LENGTH, &infoLogLen); if (infoLogLen > 0) { infoLog = new GLchar[infoLogLen]; glGetProgramInfoLog(program, infoLogLen, &charsWritten, infoLog); cout << "Program log:\n" << infoLog << endl; delete [] infoLog; } } void initShaders() { GLuint v = glCreateShader(GL_VERTEX_SHADER); GLuint f = glCreateShader(GL_FRAGMENT_SHADER); GLint vlen = strlen(vs); GLint flen = strlen(fs); glShaderSource(v, 1, &vs, &vlen); glShaderSource(f, 1, &fs, &flen); GLint compiled; glCompileShader(v); bool succ = true; glGetShaderiv(v, GL_COMPILE_STATUS, &compiled); if (!compiled) { cout << "Vertex shader not compiled." << endl; succ = false; } printShaderInfoLog(v); glCompileShader(f); glGetShaderiv(f, GL_COMPILE_STATUS, &compiled); if (!compiled) { cout << "Fragment shader not compiled." << endl; succ = false; } printShaderInfoLog(f); GLuint p = glCreateProgram(); glAttachShader(p, v); glAttachShader(p, f); glLinkProgram(p); glUseProgram(p); printProgramInfoLog(p); if (!succ) { exit(-1); } delete [] vs; delete [] fs; } int main(int argc, char* argv[]) { glutInit(&argc, argv); glutInitDisplayMode(GLUT_DOUBLE | GLUT_RGBA); glutInitWindowSize(600, 600); glutCreateWindow("Triangle Test"); glewInit(); GLenum err = glewInit(); if (GLEW_OK != err) { cout << "glewInit failed, aborting." << endl; exit(1); } cout << "Using GLEW " << glewGetString(GLEW_VERSION) << endl; const GLubyte* renderer = glGetString(GL_RENDERER); const GLubyte* vendor = glGetString(GL_VENDOR); const GLubyte* version = glGetString(GL_VERSION); const GLubyte* glslVersion = glGetString(GL_SHADING_LANGUAGE_VERSION); GLint major, minor; glGetIntegerv(GL_MAJOR_VERSION, &major); glGetIntegerv(GL_MINOR_VERSION, &minor); cout << "GL Vendor : " << vendor << endl; cout << "GL Renderer : " << renderer << endl; cout << "GL Version : " << version << endl; cout << "GL Version : " << major << "." << minor << endl; cout << "GLSL Version : " << glslVersion << endl; initShaders(); return 0; } On my video card it gives: Status: Using GLEW 1.7.0 GL Vendor : ATI Technologies Inc. GL Renderer : ATI Radeon HD 4250 GL Version : 3.3.11631 Compatibility Profile Context GL Version : 3.3 GLSL Version : 3.30 Vertex shader not compiled. Log: Vertex shader failed to compile with the following errors: ERROR: 0:1: error(#132) Syntax error: '5' parse error ERROR: error(#273) 1 compilation errors. No code generated Fragment shader not compiled. Log: Fragment shader failed to compile with the following errors: WARNING: 0:1: warning(#402) Implicit truncation of vector from size 3 to size 2. ERROR: 0:1: error(#174) Not enough data provided for construction constructor WARNING: 0:1: warning(#402) Implicit truncation of vector from size 1 to size 3. ERROR: 0:1: error(#132) Syntax error: '=' parse error ERROR: error(#273) 2 compilation errors. No code generated Program log: Vertex and Fragment shader(s) were not successfully compiled before glLinkProgram() was called. Link failed. Or if you like, you could give me other compiler messages than proposed by me. To summarize, the question is: What are GLSL compiler messages formats (INFOs, WARNINGs, ERRORs) for different vendors? Please give me examples or pattern explanation. EDIT: Ok, it seems that this question is too broad, then shortly: How does NVidia's and Intel's GLSL compilers present ERROR and WARNING messages? AMD/ATI uses patterns like this: ERROR: <position>:<line_number>: <message> WARNING: <position>:<line_number>: <message> (examples are above).

    Read the article

  • Getting macro keys from a razer blackwidow to work on linux

    - by Journeyman Geek
    I picked up a razer blackwidow ultimate that has additional keys meant for macros that are set using a tool that's installed on windows. I'm assuming that these arn't some fancypants joojoo keys and should emit scancodes like any other keys. Firstly is there a standard way to check these scancodes in linux? Secondly how do i set these keys to do things in command line and x based linux setups? My current linux install is xubuntu 10.10, but i'll be switching to kubuntu once i have a few things fixed up. Ideally the answer should be generic and system-wide Things i have tried so far: showkeys from the built in kbd package (in a seperate vt) - macro keys not detected xev - macro keys not detected lsusb and evdev output this ahk script's output suggests the M keys are not outputting standard scancodes Things i need to try snoopy pro + reverse engineering (oh dear) Wireshark - preliminary futzing around seems to indicate no scancodes emitted when what i seem to think is the keyboard is monitored and keys pressed. Might indicate additional keys are a seperate device or need to be initialised somehow. Need to cross reference that with lsusb output from linux, in 3 scenarios - standalone, passed through to a windows VM without the drivers installed, and the same with. LSUSB only detects one device on a standalone linux install It might be useful to check if the mice use the same razer synapse driver , since that means some variation of razercfg might work (not detected. only seems to work for mice) Things i have Have worked out: In a windows system with the driver, the keyboard is seen as a keyboard and a pointing device. And said pointing device uses, in addition to your bog standard mouse drivers.. a driver for something called a razer synapse. Mouse driver seen in linux under evdev and lsusb as well Single Device under OS X apparently, though i have yet to try lsusb equivilent on that Keyboard goes into pulsing backlight mode in OS X upon initialisation with the driver. This should probably indicate that there's some initialisation sequence sent to the keyboard on activation. They are, in fact, fancypants joojoo keys. Extending this question a little I have access to a windows system so if i need to use any tools on that to help answer the question, its fine. I can also try it on systems with and without the config utility. The expected end result is still to make those keys usable on linux however. I also realise this is a very specific family of hardware. I would be willing to test anything that makes sense on a linux system if i have detailed instructions - this should open up the question to people who have linux skills, but no access to this keyboard The minimum end result i require I need these keys detected, and usable in any fashion on any of the current graphical mainstream ubuntu varients

    Read the article

  • configure squid3 to set up a web proxy in ubuntu12.04

    - by Gnijuohz
    I am in a LAN and have to use a proxy given to access the web in a very limited way. I can't even use google, github.com or SE sites. However I can use ssh to log into a server, which I have root access so basically I can do anything I want with it. So I was thinking that maybe I could use that server as a proxy so I can visit sites through it. I tested it using ssh -vT [email protected] which gave a proper response. And In my computer I can't do this. Also I tried downloading something from the gun.org using wget, which can't be done in my computer too. And it succeeded on that server. I don't know if that's enough to say that this server have full access to the Internet. But I assumed so and I installed squid3 on it. After trying some while, I failed to get it working. I got this after I run squid3 -k parse 2012/07/06 21:45:18| Processing Configuration File: /etc/squid3/squid.conf (depth 0) 2012/07/06 21:45:18| Processing: acl manager proto cache_object 2012/07/06 21:45:18| Processing: acl localhost src 127.0.0.1/32 ::1 2012/07/06 21:45:18| Processing: acl to_localhost dst 127.0.0.0/8 0.0.0.0/32 ::1 2012/07/06 21:45:18| Processing: acl localnet src 10.1.0.0/16 # RFC1918 possible internal network 2012/07/06 21:45:18| Processing: acl SSL_ports port 443 2012/07/06 21:45:18| Processing: acl Safe_ports port 80 # http 2012/07/06 21:45:18| Processing: acl Safe_ports port 21 # ftp 2012/07/06 21:45:18| Processing: acl Safe_ports port 443 # https 2012/07/06 21:45:18| Processing: acl Safe_ports port 70 # gopher 2012/07/06 21:45:18| Processing: acl Safe_ports port 210 # wais 2012/07/06 21:45:18| Processing: acl Safe_ports port 1025-65535 # unregistered ports 2012/07/06 21:45:18| Processing: acl Safe_ports port 280 # http-mgmt 2012/07/06 21:45:18| Processing: acl Safe_ports port 488 # gss-http 2012/07/06 21:45:18| Processing: acl Safe_ports port 591 # filemaker 2012/07/06 21:45:18| Processing: acl Safe_ports port 777 # multiling http 2012/07/06 21:45:18| Processing: acl CONNECT method CONNECT 2012/07/06 21:45:18| Processing: http_port 3128 transparent vhost vport 2012/07/06 21:45:18| Starting Authentication on port [::]:3128 2012/07/06 21:45:18| Disabling Authentication on port [::]:3128 (interception enabled) 2012/07/06 21:45:18| Disabling IPv6 on port [::]:3128 (interception enabled) 2012/07/06 21:45:18| Processing: cache_mem 1000 MB 2012/07/06 21:45:18| Processing: cache_swap_low 90 2012/07/06 21:45:18| Processing: coredump_dir /var/spool/squid3 2012/07/06 21:45:18| Processing: refresh_pattern ^ftp: 1440 20% 10080 2012/07/06 21:45:18| Processing: refresh_pattern ^gopher: 1440 0% 1440 2012/07/06 21:45:18| Processing: refresh_pattern -i (/cgi-bin/|?) 0 0% 0 2012/07/06 21:45:18| Processing: refresh_pattern (Release|Packages(.gz)*)$ 0 20% 2880 2012/07/06 21:45:18| Processing: refresh_pattern . 0 20% 4320 2012/07/06 21:45:18| Processing: ipcache_high 95 2012/07/06 21:45:18| Processing: http_access allow all I deleted some allow and deny rules and added http_access allow all so that all the request would be allowed. After configuring my computer, I got this error: Access control configuration prevents your request from being allowed at this time. Please contact your service provider if you feel this is incorrect. And the log in the server showed that my TCP requests had all been denied. So, first of all, is what I am trying to do achievable? If so, how to configure the squid in the server so that I use it as a proxy to surf the Internet? My computer and the server both run Ubuntu11.04. Thanks for any help~

    Read the article

  • TomCat starts, but does not load properly

    - by user37136
    Hey guys, I've been working on this for a day now and still don't know what's wrong. I am essentially building a second environment for our web and app server. I got apache to load up just fine, but tomcat is proving to be difficult. It appears to start and load just fine, but when it comes to loading our application, its just got stuck for 2-5 minutes and then shut down. Here is the log on the original machine where it works fine: 2010-02-12 11:52:40,506 INFO Web application servlet context is initializing... 2010-02-12 11:52:40,540 DEBUG Servlet context attribute added: select_jobType=[{1,Undefined}, {100,Completion}, {200,Plugging}, {300,R+M}, {400,Workover}, {500,Swab - tubing}, {600,Swab - fluid}] 2010-02-12 11:52:40,540 DEBUG Servlet context attribute added: select_jobTaskType=[{1,Undefined}, {100,Rod part}, {200,Tubing leak}, {300,Pump change}, {400,Stripping job}, {500,Long stroke}, {600,A/L optimization}] 2010-02-12 11:52:40,541 DEBUG Servlet context attribute added: select_wellType=[{1,Undefined}, {100,Rod pump}, {200,ESP}, {300,Injector}, {400,PC pump}, {500,Co-Rod}, {600,Flowing}, {700,Storage}] 2010-02-12 11:52:40,541 DEBUG Servlet context attribute added: select_assetType=[{1,Rig}, {100,Disabled rig}] 2010-02-12 11:52:40,542 DEBUG Servlet context attribute added: select_state=[{AL,Alabama}, {AK,Alaska}, {AZ,Arizona}, {AR,Arkansas}, {CA,California}, {CO,Colorado}, {CT,Connecticut}, {DE,Delaware}, {FL,Florida}, {GA,Georgia}, {HI,Hawaii}, {ID,Idaho}, {IL,Illinois}, {IN,Indiana}, {IA,Iowa}, {KS,Kansas}, {KY,Kentucky}, {LA,Louisiana}, {ME,Maine}, {MD,Maryland}, {MA,Massachusetts}, {MI,Michigan}, {MN,Minnesota}, {MS,Mississippi}, {MO,Missouri}, {MT,Montana}, {NE,Nebraska}, {NV,Nevada}, {NH,New Hampshire}, {NJ,New Jersey}, {NM,New Mexico}, {NY,New York}, {NC,North Carolina}, {ND,North Dakota}, {OH,Ohio}, {OK,Oklahoma}, {OR,Oregon}, {PA,Pennsylvania}, {RI,Rhode Island}, {SC,South Carolina}, {SD,South Dakota}, {TN,Tennessee}, {TX,Texas}, {UT,Utah}, {VT,Vermont}, {VA,Virginia}, {WA,Washington}, {WV,West Virginia}, {WI,Wisconsin}, {WY,Wyoming}, {ACO,Atlantic Coast Offshore}, {FOAK,Federal Offshore Alaska}, {NGOM,Northern Gulf of Mexico}, {PCO,Pacific Coastal Offshore}] 2010-02-12 11:52:40,542 INFO KeyviewContextMonitor.contextInitialized: Loaded drop-down lists:com/key/portal/web/common/lists.properties 2010-02-12 11:52:40,937 DEBUG Servlet context attribute added: org.apache.struts.action.SERVLET_MAPPING=*.do 2010-02-12 11:52:40,937 DEBUG Servlet context attribute added: org.apache.struts.action.ACTION_SERVLET=org.apache.struts.action.ActionServlet@155d578 2010-02-12 11:52:41,939 DEBUG Servlet context attribute added: org.apache.struts.action.MODULE=org.apache.struts.config.impl.ModuleConfigImpl@e08e9d 2010-02-12 11:52:41,962 DEBUG Servlet context attribute added: org.apache.struts.action.FORM_BEANS=org.apache.struts.action.ActionFormBeans@b31c3c 2010-02-12 11:52:41,967 DEBUG Servlet context attribute added: org.apache.struts.action.FORWARDS=org.apache.struts.action.ActionForwards@102c646 2010-02-12 11:52:41,973 DEBUG Servlet context attribute added: org.apache.struts.action.MAPPINGS=org.apache.struts.action.ActionMappings@127276a 2010-02-12 11:52:41,974 DEBUG Servlet context attribute added: org.apache.struts.action.MESSAGE=org.apache.struts.util.PropertyMessageResources@18cae13 2010-02-12 11:52:41,984 DEBUG Servlet context attribute added: org.apache.struts.action.PLUG_INS=[Lorg.apache.struts.action.PlugIn;@f875ae 2010-02-12 11:52:46,816 INFO Sucessfully loaded application properties com/key/core/properties/application On my second environment, it didn't execute the last line. I start tomcat with the exact same command line !/bin/ksh export JAVA_HOME=/app/java export CATALINA_HOME=/app/tomcat export CATALINA_BASE=/app/keyview/appserver CATALINA_OPTS=" -Xms128m -Xmx800m -Dapplication.props=com/key/core/properties/application -Dlog4j.configuration=com/key/core/log/log4j.xml -Djava.awt.headless=true -Dlog4j.debug" export CATALINA_OPTS ${CATALINA_HOME}/bin/startup.sh I bolded the line that I think are in error. Thanks

    Read the article

  • Use windows 7 inside virtual box,as guest i mean, to create a Windows 7 USB using "Windows 7 USB/DVD Download Tool" ? (Linux as host)

    - by Abel Coto
    I want to download the Windows 7 professional iso (x32), from microsoft, and , i can do two things. Or buy a new burner , as mine doesn't work (i am trying to decide what dvd writer i could buy) or use a usb dongle to copy the iso to it , and install it via usb. I want to install Windows 7 in a netbook that now has debian,and in my pc. I think i have to buy only the license for the pc , as the netbook came with windows 7 preinstalled, so i suppose that i can use that serial to activate the windows , although i don't know how to install windows 7 starter instead of professional (i think if you remove a file from the iso, windows let you choose the edition to install). The problem is that in both pcs there isn't any windows , only debian. My father has a netbook with windows 7 starter, but i think it hasn't antivirus (at least until have the Karspersky Internet security for 3 pcs bought ), and i don't trust to make the usb there , if i don't now that there isn't any virus or malware. So i am trying to find a way of Create a Windows 7 usb installation , to at least be able to install windows 7 in the netbook without a external dvd writer. I know that with dd in linux you can copy a debian.iso to the usb , and then install debian with it (i've done it) using something like dd if=win7.iso of=/dev/sdb, but i don't know if this would work for windows 7 iso,and if dd will correctly copy the iso to the usb. I suppose that if you are able to boot and install windows 7 from the usb , is that the method works,and you can forget of problems later with the windows 7 installation (problems because some files could not be copied or like). So , i remembered that Microsoft created a tool to copy the iso to the usb using windows. So i thought that i could install in my pc , virtual box , as i have VT and 8 GB ram in it, and download the iso from microsoft ,install windows 7 in the virtual machine , and then copy the iso inside the machine , donwload the iso tool, and atach a usb to the pc, connect it to the guest , and use the tool to copy the iso to the USB. But i don't now if is possible to use a virtual machine to do this , or the virtualization could give problems with the usb, or something. I have found some minutes ago this How to make a windows 7 usb flash install media, from linux? The first method (dd) is the one i like more , and i trust more ( i don't now if the second method using ms-sys , works well , and if i can trust it. I understand that a iso is like a .rar , but no compressed,only containing the files ,so mount the iso and cp the data inside perhaps is ok. Although the method i like more is the microsoft one (more because is from microsoft , and i suppose they now what they do ,at least with this usb related thing, than anything). Perhaps worth more to buy a external dvd writer haha ... Should the virtual machine method work ?

    Read the article

  • git private server error: "Permission denied (publickey)."

    - by goddfree
    I followed the instructions here in order to set up a private git server on my Amazon EC2 instance. However, I am having problems when trying to SSH into the git account. Specifically, I get the error "Permission denied (publickey)." Here are the permissions of my files/folders on the EC2 server: drwx------ 4 git git 4096 Aug 13 19:52 /home/git/ drwx------ 2 git git 4096 Aug 13 19:52 /home/git/.ssh -rw------- 1 git git 400 Aug 13 19:51 /home/git/.ssh/authorized_keys Here are the permissions of my files/folders on my own computer: drwx------ 5 CYT staff 170 Aug 13 14:51 .ssh -rw------- 1 CYT staff 1679 Aug 13 13:53 .ssh/id_rsa -rw-r--r-- 1 CYT staff 400 Aug 13 13:53 .ssh/id_rsa.pub -rw-r--r-- 1 CYT staff 1585 Aug 13 13:53 .ssh/known_hosts When checking my logs in /var/log/secure, I used to get the following error message every time I tried to SSH: Authentication refused: bad ownership or modes for file /home/git/.ssh/authorized_keys However, after making a few permission changes, I no longer get this error message. Despite this, I am still getting the "Permission denied (publickey)." message every time I try to SSH. The command I am using to SSH is ssh -T git@my-ip. Here is the full log I get when I run ssh -vT [email protected]: OpenSSH_6.2p2, OSSLShim 0.9.8r 8 Dec 2011 debug1: Reading configuration data /etc/ssh_config debug1: /etc/ssh_config line 20: Applying options for * debug1: Connecting to my-ip [my-ip] port 22. debug1: Connection established. debug1: identity file /Users/CYT/.ssh/id_rsa type -1 debug1: identity file /Users/CYT/.ssh/id_rsa-cert type -1 debug1: identity file /Users/CYT/.ssh/id_dsa type -1 debug1: identity file /Users/CYT/.ssh/id_dsa-cert type -1 debug1: Enabling compatibility mode for protocol 2.0 debug1: Local version string SSH-2.0-OpenSSH_6.2 debug1: Remote protocol version 2.0, remote software version OpenSSH_6.2 debug1: match: OpenSSH_6.2 pat OpenSSH* debug1: SSH2_MSG_KEXINIT sent debug1: SSH2_MSG_KEXINIT received debug1: kex: server->client aes128-ctr [email protected] none debug1: kex: client->server aes128-ctr [email protected] none debug1: SSH2_MSG_KEX_DH_GEX_REQUEST(1024<1024<8192) sent debug1: expecting SSH2_MSG_KEX_DH_GEX_GROUP debug1: SSH2_MSG_KEX_DH_GEX_INIT sent debug1: expecting SSH2_MSG_KEX_DH_GEX_REPLY debug1: Server host key: RSA 08:ad:8a:bc:ab:4d:5f:73:24:b2:78:69:46:1a:a5:5a debug1: Host 'my-ip' is known and matches the RSA host key. debug1: Found key in /Users/CYT/.ssh/known_hosts:1 debug1: ssh_rsa_verify: signature correct debug1: SSH2_MSG_NEWKEYS sent debug1: expecting SSH2_MSG_NEWKEYS debug1: SSH2_MSG_NEWKEYS received debug1: Roaming not allowed by server debug1: SSH2_MSG_SERVICE_REQUEST sent debug1: SSH2_MSG_SERVICE_ACCEPT received debug1: Authentications that can continue: publickey debug1: Next authentication method: publickey debug1: Trying private key: /Users/CYT/.ssh/id_rsa debug1: Trying private key: /Users/CYT/.ssh/id_dsa debug1: No more authentication methods to try. Permission denied (publickey). I have spent a few hours going through threads on various sites, including SO and SF, looking for a solution. It seems that the permissions for my files are all okay, but I just can't figure out the problem. Any help would be greatly appreciated. Edit: EEAA: Here are the outputs you requested: $ getent passwd git git:x:503:504::/home/git:/bin/bash $ grep ssh ~git/.ssh/authorized_keys | wc -l grep: /home/git/.ssh/authorized_keys: Permission denied 0

    Read the article

  • "CB Monitor Windows" proccess blocks XP shutdown

    - by Shiki
    I've got a home server. Simple, low-power-consumption Intel Atom based PC built by me. It runs XP since Win7 was an overkill for this poor thing. Everything was OK, always used Avast! antivirus + Spybot. However, it stopped shutting down after a while. Few days ago I noticed a "CB Monitor Windows" proccess is blocking this (didn't quit from rdp after sending the shutdown command). What is this proccess? How can I disable/remove it? Tried Malwarebytes, found ONE malware, removed it, did a reboot, no change. Avast is up-to-date, Spybot is the same. What could I do?

    Read the article

  • Windows update error code : 80244004

    - by Hamidreza
    I am using Windows 7 and ESET SMART SECURITY 5 . Today I wanted to update my computer using Windows Update but it does give me error : Error(s) found: Code 80244004        Windows Update encountered an unknown error. My System Info : Sony Vaio EA2gfx , Ram : 4GB DDR2 , CPU: Intel Core i 5 I checkd out this links but they didn't help : http://answers.microsoft.com/en-us/windows/forum/windows_7-windows_update/while-updating-i-am-getting-the-error-code/0b9b756c-5b6e-4571-838e-f90c48a4e00c https://www.calguns.net/calgunforum/showthread.php?t=583860 http://www.sevenforums.com/windows-updates-activation/235807-windows-update-error-80244004-a.html Please help me, thanks.

    Read the article

< Previous Page | 104 105 106 107 108 109 110 111 112 113 114 115  | Next Page >