Search Results

Search found 56726 results on 2270 pages for 'harry foxwell(at)oracle com'.

Page 11/2270 | < Previous Page | 7 8 9 10 11 12 13 14 15 16 17 18  | Next Page >

  • Making .NET assembly COM-visible and working for VB5

    - by Cyberherbalist
    I have an assembly which I have managed to make visible to VB6 and it works, but having a problem accomplishing the same thing with VB5. For VB6, I have built the assembly, made it COM-visible, registered it as a COM object etc., and the assembly shows in VB6's References list, and allows me to use it successfully. The Object Browser also shows the method in the assy. I copied the assembly and its TLB to a virtual workstation used for VB5 development, and ran Regasm, apparently successfully: C:\>C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727 \regasm arserviceinterface.dll /tlb:arserviceinterface.tlb Microsoft (R) .NET Framework Assembly Registration Utility 2.0.50727.3053 Copyright (C) Microsoft Corporation 1998-2004. All rights reserved. Assembly exported to 'C:\Projects\AR\3rd Party\ARService\arserviceinterface.tlb' , and the type library was registered successfully Note that the virtual W/S is Win2k and does not have .NET Fx 3.5 on it, just 2.0. The assembly shows up in the References that can be selected in VB5, but the method of the assembly doesn't show up in the Object Browser, and it is generally unusable. Either there is a step to do that I haven't done, or VB5 doesn't know how to use such a COM object. Note that the VB5 setup is on a virtual workstation, not the same workstation that VB6 is installed on. Any ideas? One thing that occurred to me is that I might need to generate and use a strong name on the workstation in question, but...

    Read the article

  • Retrieve COM ProgID from exe without registering it

    - by mangelo
    Background: I would like to extract the COM data from a VB6 application so I can register it correctly (according to Microsoft best practice) the application. I am using WiX 3.0 and heat.exe will not extract the data (known issue with heat) and I do not have ready access to the associated TLB file. The VB6 application does not have compatibility turned on so it regenerates the COM GUIDs every build (They want to have the application be able to run side by side with an older version.) I created a C# application that will collect the TypeLib, interface and CoClass information from the VB6 application without registering it and create a wxs file for candle to use. My company has several other older applications like this and I would like to make it a more generic solution. The Issues: 1.Is there a way to collect the 'true' ProgID (programmer intended one) from the application with out the project or TLB file and without registering it? 2.Is there a way to find out the intended Threading Model from a DLL without registering it? (I intend that it can handle all COM active items, might as well be complete) Thank you.

    Read the article

  • How to wrap a thirdparty library COM class for notifications in a C++ project

    - by geocoin
    A thirdparty vendor has provided a COM interface as an external API to their product, and for sending instructions to it, it's fine with the mechanism of generating class wrappers with visual studio by importing from the dll, then creating instances of the created classes, calling their CreateDispatch(), using the access functions and releasing when done. For return notifications, I'd normally create an EventsListener class derived from IDispatch using the Invoke function to handle events returning from the interface. This vendor has created an Events lass which I have to wrap and expose, then explicitly tell the installation where to look. all the example are given is C# where it's really easy, but I'm struggling on how to do it in C++ in the C# example, the interop dll provided is simply added as a reference and derived into a class like so: using System; using System.Runtime.InteropServices; using System.Windows.Forms; using System.Text; using <THIER INTEROP LIB> namespace some.example.namespace { [ComVisible(true)] public class EventViewer : IEvents //where IEvents is their events class { public void OnEvent(EventID EventID, object pData) //overridden function { //event handled here } } } In broad terms I assume that I must create a COM interface, since they require a ProgID from me to instantiate, but how do I derive that's been wrapped by the import and then expose the created class to COM I'm just not sure where to even start, as all the tutorials I've seen so far talk in terms of creating brand new classes not wrapping a third party one

    Read the article

  • error while installing ia32-libs

    - by user3405516
    I am trying to install "ia32-libs" After doing google I did following steps. Yet not able to do it... 1st step i have added dpkg --add-architecture i386 2nd step added "deb http://archive.ubuntu.com/ubuntu/ raring main restricted universe multiverse" ia32-libs-raring.list" root@user:/etc/apt/sources.list.d# sudo dpkg --add-architecture i386 root@user:/etc/apt/sources.list.d# echo "deb http://archive.ubuntu.com/ubuntu/ raring main restricted universe multiverse" >ia32-libs-raring.list root@user:/etc/apt/sources.list.d# apt-get update Ign http://us-east-1.ec2.archive.ubuntu.com trusty InRelease Ign http://security.ubuntu.com trusty-security InRelease Ign http://archive.ubuntu.com raring InRelease Ign http://us-east-1.ec2.archive.ubuntu.com trusty-updates InRelease Hit http://security.ubuntu.com trusty-security Release.gpg Ign http://archive.ubuntu.com raring Release.gpg Hit http://us-east-1.ec2.archive.ubuntu.com trusty Release.gpg Hit http://security.ubuntu.com trusty-security Release Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates Release.gpg Ign http://archive.ubuntu.com raring Release Hit http://us-east-1.ec2.archive.ubuntu.com trusty Release Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates Release Hit http://security.ubuntu.com trusty-security/main Sources Hit http://us-east-1.ec2.archive.ubuntu.com trusty/main Sources Hit http://security.ubuntu.com trusty-security/universe Sources Hit http://us-east-1.ec2.archive.ubuntu.com trusty/universe Sources Hit http://security.ubuntu.com trusty-security/main amd64 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty/main amd64 Packages Hit http://security.ubuntu.com trusty-security/universe amd64 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty/universe amd64 Packages Hit http://security.ubuntu.com trusty-security/main i386 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty/main i386 Packages Hit http://security.ubuntu.com trusty-security/universe i386 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty/universe i386 Packages Hit http://security.ubuntu.com trusty-security/main Translation-en Hit http://security.ubuntu.com trusty-security/universe Translation-en Hit http://us-east-1.ec2.archive.ubuntu.com trusty/main Translation-en Hit http://us-east-1.ec2.archive.ubuntu.com trusty/universe Translation-en Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/main Sources Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/universe Sources Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/main amd64 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/universe amd64 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/main i386 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/universe i386 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/main Translation-en Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/universe Translation-en Ign http://us-east-1.ec2.archive.ubuntu.com trusty/main Translation-en_US Ign http://us-east-1.ec2.archive.ubuntu.com trusty/universe Translation-en_US Err http://archive.ubuntu.com raring/main amd64 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/restricted amd64 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/universe amd64 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/multiverse amd64 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/main i386 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/restricted i386 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/universe i386 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/multiverse i386 Packages 404 Not Found [IP: 91.189.91.13 80] Ign http://archive.ubuntu.com raring/main Translation-en_US Ign http://archive.ubuntu.com raring/main Translation-en Ign http://archive.ubuntu.com raring/multiverse Translation-en_US Ign http://archive.ubuntu.com raring/multiverse Translation-en Ign http://archive.ubuntu.com raring/restricted Translation-en_US Ign http://archive.ubuntu.com raring/restricted Translation-en Ign http://archive.ubuntu.com raring/universe Translation-en_US Ign http://archive.ubuntu.com raring/universe Translation-en W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/main/binary-amd64/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/restricted/binary-amd64/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/universe/binary-amd64/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/multiverse/binary-amd64/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/main/binary-i386/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/restricted/binary-i386/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/universe/binary-i386/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/multiverse/binary-i386/Packages 404 Not Found [IP: 91.189.91.13 80] E: Some index files failed to download. They have been ignored, or old ones used instead.

    Read the article

  • How to diagnose cause, fix, or work around Adobe ActiveX / COM related error 0x80004005 progmaticall

    - by Streamline
    I've built a C# .NET app that uses the Adobe ActiveX control to display a PDF. It relies on a couple DLLs that get shipped with the application. These DLLs interact with the locally installed Adobe Acrobat or Adobe Acrobat Reader installed on the machine. This app is being used by some customer already and works great for nearly all users ( I check to see that the local machine is running at least version 9 of either Acrobat or Reader already ). I've found 3 cases where the app returns the error message "Error HRESULT E_FAIL has been returned from a call to a COM component" when trying to load (when the activex control is loading). I've checked one of these user's machines and he has Acrobat 9 installed and is using it frequently with no problems. It does appear that Acrobat 7 and 8 were installed at one time since there are entries for them in the registry along with Acrobat 9. I can't reproduce this problem locally, so I am not sure exactly which direction to go. The error at the top of the stacktrace is: System.Runtime.InteropServices.COMException (0x80004005): Error HRESULT E_FAIL has been returned from a call to a COM component. Some research into this error indicates it is a registry problem. Does anyone have a clue as to how to fix or work around this problem, or determine how to get to the core root of the problem? The full content of the error message is this: System.Runtime.InteropServices.COMException (0x80004005): Error HRESULT E_FAIL has been returned from a call to a COM component.    at System.Windows.Forms.UnsafeNativeMethods.CoCreateInstance(Guid& clsid, Object punkOuter, Int32 context, Guid& iid)    at System.Windows.Forms.AxHost.CreateWithoutLicense(Guid clsid)    at System.Windows.Forms.AxHost.CreateWithLicense(String license, Guid clsid)    at System.Windows.Forms.AxHost.CreateInstanceCore(Guid clsid)    at System.Windows.Forms.AxHost.CreateInstance()    at System.Windows.Forms.AxHost.GetOcxCreate()    at System.Windows.Forms.AxHost.TransitionUpTo(Int32 state)    at System.Windows.Forms.AxHost.CreateHandle()    at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)    at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)    at System.Windows.Forms.AxHost.EndInit()    at AcrobatChecker.Viewer.InitializeComponent()    at AcrobatChecker.Viewer..ctor()    at AcrobatChecker.Form1.btnViewer_Click(Object sender, EventArgs e)    at System.Windows.Forms.Control.OnClick(EventArgs e)    at System.Windows.Forms.Button.OnClick(EventArgs e)    at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent)    at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks)    at System.Windows.Forms.Control.WndProc(Message& m)    at System.Windows.Forms.ButtonBase.WndProc(Message& m)    at System.Windows.Forms.Button.WndProc(Message& m)    at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)    at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)    at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)

    Read the article

  • Loose coupling of COM in C# or How to avoid COMException 0x80040154

    - by user283318
    I have a .Net 2 C# application I am developing which uses a VB 6 generated COM DLL. The VB DLL is updated frequently any my application crashes with a System.Runtime.InteropServices.COMException (0x80040154). The part of the COM DLL I use does not change but the version (and CLSID) will. The "Specific Version" option for the reference is false. The WrapperTool is tlbimp. How do I tell my application not to worry about changes in the DLL? Is there any way of checking just the functions I am using?

    Read the article

  • Outlook 2003 add-in - Getting COM exception on application shutdown after creating WPF window

    - by Oliver Hanappi
    Hi! I'm developing an outlook 2003 add-in. Until now I used only winforms to display one form, but today I've added a WPF window for more complex stuff. DUe to the WPF window, a COM exception is being thrown when outlook shuts down. Does anybody know why? I need to start a separate thread for the WPF window in single apartment state. Here is the exception: System.Runtime.InteropServices.InvalidComObjectException was unhandled Message="COM object that has been separated from its underlying RCW cannot be used." Source="PresentationCore" StackTrace: at System.Windows.Input.TextServicesContext.StopTransitoryExtension() at System.Windows.Input.TextServicesContext.Uninitialize(Boolean appDomainShutdown) at System.Windows.Input.TextServicesContext.TextServicesContextShutDownListener.OnShutDown(Object target) at MS.Internal.ShutDownListener.HandleShutDown(Object sender, EventArgs e) InnerException: Best Regards, Oliver Hanappi

    Read the article

  • Good freeware COM/ActiveX Type Library Explorer?

    - by Tomalak
    I used to have a dated, but valuable solution to display COM/ActiveX control- and type-library contents (ProgIDs, method names and signatures, enumerations, constants, interfaces/coclasses, etc.) of all such libraries registered on my system. It provided an Explorer-like overview of everything that was available to ActiveX development/scripting and served as an automatic API documentation tool since official docs for most COM/ActiveX libraries are either missing completely or fragmentary at best. My recent move to a 64bit Windows rendered the program I had unusable, due to internal dependencies on the 32bit VB6 runtime (comctl32.ocx) that is no longer supported on 64bit Windows. Does anyone know an alternative that still works?

    Read the article

  • Using COM to open Word

    - by chupinette
    Hello! I am actually trying some codes i found from http://php.net/manual/en/class.com.php <?php // starting word $word = new COM("word.application") or die("Unable to instantiate Word"); echo "Loaded Word, version {$word->Version}\n"; //bring it to front $word->Visible = 1; //open an empty document $word->Documents->Add(); //do some weird stuff $word->Selection->TypeText("This is a test..."); $word->Documents[1]->SaveAs("Useless test.doc"); //closing word $word->Quit(); //free the object $word = null; ?> But this does not seem to work. I am using Word 2007 and i get the following: Loaded Word, version 12.0 Fatal error: Call to undefined method variant::SaveAs() in C:\xampp\htdocs\final\testq.php on line 14 Can anyone solve this problem? Is it because i am using Word 2007?

    Read the article

  • Exposing .NET enums to COM clients{VBScript}

    - by Codex
    Am trying create of PoC for exposing/invoking various .NET objects from COM clients. The .NET library contains some classes and Enums. Am able to successfully access the classes in VBScript but not able to access the Enums. I know that Enums are value types and hence 'CreateObject' wont work in this case. But am able to access the same Enum in VBA code. Questions: How can I access the enums in VBScript? Why does the behaviour differ in the two COM clients? If VBA object browser can see the enum, why cant VBScript allow me to create one? .NET [ComVisible(true)] [GuidAttribute("ebc25cf6-9120-4283-b972-0e5520d0000E")] public enum Currency { GBP = CurrencyConvertorBL.CurrencyConvertorRef.Currency.GBP, USD = CurrencyConvertorBL.CurrencyConvertorRef.Currency.USD, INR = CurrencyConvertorBL.CurrencyConvertorRef.Currency.INR, AUD = CurrencyConvertorBL.CurrencyConvertorRef.Currency.AUD } VBA Private Function ConvertCurrency(fromCurrency As Currency, toCurrency As Currency) As Double VBScript ??? Set currencyConvertorCCY = CreateObject("CurrencyConvertorBL.Currency") Thanks in advance.

    Read the article

  • How does COM registration work in Windows

    - by Air Benji
    I'm an application packager trying to make sense of how the COM registry keys (SelfReg) interrelate to the given .dll in Windows. ProgID's, AppID's, TypeLibs, Extensions & Verbs are all tied around the CLSID right? Do CLSID's always use Prog/App IDs or could you just have a file extension class? Which bits are optional? Some of it seems to be 'like a router' where there's the two interfaces (internal - .dll) and external (the extension etc). How does this all fit? (The SDK documentation doesn't make sense to me) I ask as this is all pivotal to application 'healing' with Windows Installer (which packagers are all 'big' on, but there's no nitty-gritty breakdowns since its a coder-thing really) ---Edit: Am I safe in assuming that for what COM is registered, it must all link back to the CLSID and cannot be a 'dead-end'? Verbs need extensions which need progid's... What about the AppId's, TypeLibs and Interfaces? How do they interrelate?

    Read the article

  • Accessing Bluetooth virtual COM port on Windows without manual pairing

    - by oo_olo_oo
    I need to connect to a Bluetooth device through virtual COM port created in Windows. It's easy when the port has been already created during manual pairing procedure. But I would like my application to relieve an user from the manual pairing of a device. I would like to present all devices in the range, allow user to chose one, and then create virtual COM port connected with the selected device. I'm not trying to avoid the pairing procedure itself, but rather I would like to invoke it by my application. I started getting familiar with Microsoft Bluetooth API. And then some doubts arose. I've been wondering what happen if some user would use different (than Microsoft's) Bluetooth stack? Is the Microsoft's API the real Bluetooth API, which have to be implemented by any other Bluetooth stack provider? Or rather each provider has its own API, and the Microsoft's is only one of many other?

    Read the article

  • Passing a string from C# to cpp with COM

    - by Yaron Naveh
    I have a C# COM server which is consumed by a cpp client. One of the C# methods returns a string. In cpp the returned string is represented in Unicode (UTF-16), at least according to the memory view. Is this always the case with COM strings? Is there a way to use UTF-8 instead? I saw some code where strings were passed between cpp and c# as byte arrays. Is there any benefit in this?

    Read the article

  • any command line com port query tools?

    - by c_programmer
    ok folks, heres my dilemma i want to make a chat program that uses sms as its base engine.. to do this i need to communicate with my gsm phone via bluetooth attached to com 7 on my computer.. i can do this fine using hyperterminal, tera term etc. but to hav an un-obtrusive, friendly interface i need a command line tool to send AT commands, (and receive responses) to/from my mobile phone through my com port.. i have been searching for days to no avail.. please help

    Read the article

  • Invoke a COM addin option from VBA

    - by rip
    Can I invoke an option on a COM Add-in from a VBA macro in Word or Excel 2007? The COM Add-in was written using VSTO – it adds a custom ribbon tab with a number of options that I want to execute from a VBA macro. I can reference the add-in using Application.COMAddIns("MyAddinName") but I can’t find an option to invoke an option. I’ve also played around with the Application.CommandBars collection, and can see that you can execute an option using CommandBarControl.Execute but I can’t find my command bar in the Application.CommandBars collection. Does anyone know if this is possible?

    Read the article

  • Explore a COM Object in PHP

    - by shaiss
    What would be the proper way to explode a COM object for debugging? I have a 3rd party function that returns a multilevel object. The documentation is non existant, so I'd like to be able to echo everything out of the object or debug it in Komodo IDE. Komodo just says Object and nothing else. Maybe convert to array? I know some of the existing options such as $com->Status, but there are more variables returned that I'd like to know what they are.

    Read the article

  • Getting the version of a COM object

    - by Shao
    I am accessing a .NET COM object from C++. I want to know the version information about this COM object. When I open the TLB in OLEVIEW.exe I can see the version information associated with the coclass. How can I access this information from C++? This is the information I get: [ uuid(XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX), version(1.0), custom(XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX, XXXX) ] coclass XXXXXXXX{ [default] interface XXXXXXXX; interface _Object; interface XXXXXXXX; };

    Read the article

  • Getting COM object to run in Vista

    - by rainslg
    We expose an interface to our simulation software using a COM/ActiveX object. This worked just fine in XP, but in Vista, we get "Error 429: ActiveX can't create object" when a VB client executes CreateObject(). The COM object has been registered by hand so that the Vista Registry is identical to XP's Registry. I run the VB interface from a DOS window that I started using "Run As Administrator". The client is correctly accessing and reading the Registry as I walk through using the debugger in VB, so it's apparently not a security setting, as near as I can tell. I have also loaded the files into VS2005 (the object was originally created in VS6) and rebuilt them to get a later ATL version, but that hasn't helped - we still get the 429 error. Is this a symptom of UAC problems, or should I be looking for something deeper?

    Read the article

  • Extract a C/C++ header file from a C# class exposed to COM

    - by isorfir
    I'm not sure I've setup everything I've needed to in my C# class to properly, but it does work in COM. I've been looking for an example of a C# class that was successfully used in a C/C++ project, but haven't come across anything. I've tried using the OLE/COM Object View app to open the .tlb file and save as .h, but it gives some errors: MIDL1009: unknown argument ignored; MIDL1001: cannot open input file Studio "Studio" isn't the name of the file, it's Syslog, so that raises a red flag to me. Any ideas?

    Read the article

  • COM port - how to identify a device (.net/c#)

    - by argh
    Hi, I'm programming for Windows CE and I need to connect to a scanner. There is no problem - I know that it is on port COM0, but if I plug in another device earlier it gets another COM port... to get all com ports the easy way is: SerialPort.GetPortNames() But I don't know how to identify a device? Is there any standard way? I can't 'ping' it since there is one device that only sends data... it spams data all the time... and I don't know how to 'ping' a device...

    Read the article

  • Problems with DNS propagation 10 days after a change was made

    - by runlevel6
    The engineering team I work with has been in the process of moving equipment from one datacenter to another. Ten days ago we moved one of our name servers authoritative for our client's domains (ns1.faithhiway.com) and updated its IP address with its respective DNS provider (register.com) to point to the new datacenter. All tests done show that this name server is correctly running at its new location and when queried, returning the correct response for any domains it is responsible for. The problem is that well after 72 hours had gone by we were still seeing more DNS activity at its old IP address than at the new. The good news is that we kept a name server responding on the old IP address for the time being so we are not seeing any issues with the domains our nameserver is responsible for but the goal is to retire that as soon as possible. As you can see from WhatsMyDNS.net, a decent amount of propagation has occurred over the last 10 days since we made this change, but still there are some locations reporting our original IP. Considering that the TTL is only 3600 with the name servers responsible for this domain, it does not make any sense to myself or the other engineers working with me that we are having this issue. Now if I run a DNS check using one of the Register.com DNS servers (direct nameservers for faithhiway.com), I get the following (correct) result: # dig @dns01.gpn.register.com ns1.faithhiway.com A ; <<>> DiG 9.3.6-P1-RedHat-9.3.6-4.P1.el5_5.3 <<>> @dns01.gpn.register.com. ns1.faithhiway.com A ; (1 server found) ;; global options: printcmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 43232 ;; flags: qr aa; QUERY: 1, ANSWER: 1, AUTHORITY: 5, ADDITIONAL: 5 ;; QUESTION SECTION: ;ns1.faithhiway.com. IN A ;; ANSWER SECTION: ns1.faithhiway.com. 3601 IN A 206.127.2.71 ;; AUTHORITY SECTION: faithhiway.com. 3600 IN NS dns01.gpn.register.com. faithhiway.com. 3600 IN NS dns02.gpn.register.com. faithhiway.com. 3600 IN NS dns03.gpn.register.com. faithhiway.com. 3600 IN NS dns04.gpn.register.com. faithhiway.com. 3600 IN NS dns05.gpn.register.com. ;; ADDITIONAL SECTION: dns01.gpn.register.com. 3600 IN A 98.124.192.1 dns02.gpn.register.com. 3600 IN A 98.124.197.1 dns03.gpn.register.com. 3600 IN A 98.124.193.1 dns04.gpn.register.com. 3600 IN A 69.64.145.225 dns05.gpn.register.com. 3600 IN A 98.124.196.1 ;; Query time: 50 msec ;; SERVER: 98.124.192.1#53(98.124.192.1) ;; WHEN: Thu Jan 27 15:16:57 2011 ;; MSG SIZE rcvd: 269 Just as a reference, here are the results when the same query is checked against a variety of Public DNS servers: Google: # dig @8.8.8.8 ns1.faithhiway.com A ; <<>> DiG 9.3.6-P1-RedHat-9.3.6-4.P1.el5_5.3 <<>> @8.8.8.8. ns1.faithhiway.com A ; (1 server found) ;; global options: printcmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 12773 ;; flags: qr rd ra; QUERY: 1, ANSWER: 1, AUTHORITY: 0, ADDITIONAL: 0 ;; QUESTION SECTION: ;ns1.faithhiway.com. IN A ;; ANSWER SECTION: ns1.faithhiway.com. 997 IN A 206.127.2.71 ;; Query time: 29 msec ;; SERVER: 8.8.8.8#53(8.8.8.8) ;; WHEN: Thu Jan 27 15:17:31 2011 ;; MSG SIZE rcvd: 52 Level 3: # dig @4.2.2.1 ns1.faithhiway.com A ; <<>> DiG 9.3.6-P1-RedHat-9.3.6-4.P1.el5_5.3 <<>> @4.2.2.1. ns1.faithhiway.com A ; (1 server found) ;; global options: printcmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 46505 ;; flags: qr rd ra; QUERY: 1, ANSWER: 1, AUTHORITY: 0, ADDITIONAL: 0 ;; QUESTION SECTION: ;ns1.faithhiway.com. IN A ;; ANSWER SECTION: ns1.faithhiway.com. 2623 IN A 206.127.2.71 ;; Query time: 7 msec ;; SERVER: 4.2.2.1#53(4.2.2.1) ;; WHEN: Thu Jan 27 15:18:35 2011 ;; MSG SIZE rcvd: 52 Verizon: # dig @151.197.0.38 ns1.faithhiway.com A ; <<>> DiG 9.3.6-P1-RedHat-9.3.6-4.P1.el5_5.3 <<>> @151.197.0.38. ns1.faithhiway.com A ; (1 server found) ;; global options: printcmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 32658 ;; flags: qr rd ra; QUERY: 1, ANSWER: 1, AUTHORITY: 0, ADDITIONAL: 0 ;; QUESTION SECTION: ;ns1.faithhiway.com. IN A ;; ANSWER SECTION: ns1.faithhiway.com. 3601 IN A 206.127.2.71 ;; Query time: 81 msec ;; SERVER: 151.197.0.38#53(151.197.0.38) ;; WHEN: Thu Jan 27 15:19:15 2011 ;; MSG SIZE rcvd: 52 Cisco: # dig @64.102.255.44 ns1.faithhiway.com A ; <<>> DiG 9.3.6-P1-RedHat-9.3.6-4.P1.el5_5.3 <<>> @64.102.255.44. ns1.faithhiway.com A ; (1 server found) ;; global options: printcmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 39689 ;; flags: qr rd ra; QUERY: 1, ANSWER: 1, AUTHORITY: 5, ADDITIONAL: 0 ;; QUESTION SECTION: ;ns1.faithhiway.com. IN A ;; ANSWER SECTION: ns1.faithhiway.com. 3601 IN A 206.127.2.71 ;; AUTHORITY SECTION: faithhiway.com. 3600 IN NS dns01.gpn.register.com. faithhiway.com. 3600 IN NS dns04.gpn.register.com. faithhiway.com. 3600 IN NS dns05.gpn.register.com. faithhiway.com. 3600 IN NS dns02.gpn.register.com. faithhiway.com. 3600 IN NS dns03.gpn.register.com. ;; Query time: 105 msec ;; SERVER: 64.102.255.44#53(64.102.255.44) ;; WHEN: Thu Jan 27 15:20:05 2011 ;; MSG SIZE rcvd: 165 OpenDNS: # dig @208.67.222.222 ns1.faithhiway.com A ; <<>> DiG 9.3.6-P1-RedHat-9.3.6-4.P1.el5_5.3 <<>> @208.67.222.222. ns1.faithhiway.com A ; (1 server found) ;; global options: printcmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 12328 ;; flags: qr rd ra; QUERY: 1, ANSWER: 1, AUTHORITY: 0, ADDITIONAL: 0 ;; QUESTION SECTION: ;ns1.faithhiway.com. IN A ;; ANSWER SECTION: ns1.faithhiway.com. 169507 IN A 207.200.19.162 ;; Query time: 6 msec ;; SERVER: 208.67.222.222#53(208.67.222.222) ;; WHEN: Thu Jan 27 15:19:29 2011 ;; MSG SIZE rcvd: 52 SpeakEasy: # dig @66.93.87.2 ns1.faithhiway.com A ; <<>> DiG 9.3.6-P1-RedHat-9.3.6-4.P1.el5_5.3 <<>> @66.93.87.2. ns1.faithhiway.com A ; (1 server found) ;; global options: printcmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 9342 ;; flags: qr rd ra; QUERY: 1, ANSWER: 1, AUTHORITY: 0, ADDITIONAL: 0 ;; QUESTION SECTION: ;ns1.faithhiway.com. IN A ;; ANSWER SECTION: ns1.faithhiway.com. 169323 IN A 207.200.19.162 ;; Query time: 69 msec ;; SERVER: 66.93.87.2#53(66.93.87.2) ;; WHEN: Thu Jan 27 15:19:51 2011 ;; MSG SIZE rcvd: 52 As you can see above, the majority of queries are returning the correct result. But a few (OpenDNS and SpeakEasy in the examples above) are still showing the old IP address. Considering the length of time that has gone by, it seems obvious to me that either we have made a mistake and not thoroughly handled the DNS changes on our end (likely) or there is a problem with either the DNS provider for this domain (Register) or with some of the DNS servers out in the wild (rather unlikely). Any advice on how I can proceed with this? UPDATE (January 31, 2011): First of all, I apologize for the length of both the original question and this update. I contemplated removing some of the excess from the original post but just in case this problem and its solution are helpful to someone else in the future I'm just going to leave everything as it is. Anyway, I've been doing some more research into this problem, and have discovered the following interesting occurrence. While running a check on the glue records for faithhiway.com always resolve correctly, if I go and check a client domain (where ns1.faithhiway.com is authoritative), I get a strange response. It looks like the root servers are returning nsX.faithhiway.com as their old IP addresses still (under Additional Section). Because we have a server still there responding to DNS queries, the trace finishes and returns the correct IP addresses as the final step (again, under Additional Section). The example below uses one of the domains that we use that uses ns1.faithhiway.com as its authoritative DNS server. # dig +trace +nosearch +all +norecurse ignitemail.com ; <<>> DiG 9.2.4 <<>> +trace +nosearch +all +norecurse ignitemail.com ;; global options: printcmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 46856 ;; flags: qr ra; QUERY: 1, ANSWER: 13, AUTHORITY: 0, ADDITIONAL: 0 ;; QUESTION SECTION: ;. IN NS ;; ANSWER SECTION: . 7986 IN NS a.root-servers.net. . 7986 IN NS b.root-servers.net. . 7986 IN NS c.root-servers.net. . 7986 IN NS d.root-servers.net. . 7986 IN NS e.root-servers.net. . 7986 IN NS f.root-servers.net. . 7986 IN NS g.root-servers.net. . 7986 IN NS h.root-servers.net. . 7986 IN NS i.root-servers.net. . 7986 IN NS j.root-servers.net. . 7986 IN NS k.root-servers.net. . 7986 IN NS l.root-servers.net. . 7986 IN NS m.root-servers.net. ;; Query time: 39 msec ;; SERVER: 8.8.8.8#53(8.8.8.8) ;; WHEN: Mon Jan 31 09:22:17 2011 ;; MSG SIZE rcvd: 228 ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 16325 ;; flags: qr; QUERY: 1, ANSWER: 0, AUTHORITY: 13, ADDITIONAL: 14 ;; QUESTION SECTION: ;ignitemail.com. IN A ;; AUTHORITY SECTION: com. 172800 IN NS h.gtld-servers.net. com. 172800 IN NS m.gtld-servers.net. com. 172800 IN NS i.gtld-servers.net. com. 172800 IN NS l.gtld-servers.net. com. 172800 IN NS c.gtld-servers.net. com. 172800 IN NS k.gtld-servers.net. com. 172800 IN NS d.gtld-servers.net. com. 172800 IN NS f.gtld-servers.net. com. 172800 IN NS b.gtld-servers.net. com. 172800 IN NS a.gtld-servers.net. com. 172800 IN NS e.gtld-servers.net. com. 172800 IN NS g.gtld-servers.net. com. 172800 IN NS j.gtld-servers.net. ;; ADDITIONAL SECTION: a.gtld-servers.net. 172800 IN A 192.5.6.30 a.gtld-servers.net. 172800 IN AAAA 2001:503:a83e::2:30 b.gtld-servers.net. 172800 IN A 192.33.14.30 b.gtld-servers.net. 172800 IN AAAA 2001:503:231d::2:30 c.gtld-servers.net. 172800 IN A 192.26.92.30 d.gtld-servers.net. 172800 IN A 192.31.80.30 e.gtld-servers.net. 172800 IN A 192.12.94.30 f.gtld-servers.net. 172800 IN A 192.35.51.30 g.gtld-servers.net. 172800 IN A 192.42.93.30 h.gtld-servers.net. 172800 IN A 192.54.112.30 i.gtld-servers.net. 172800 IN A 192.43.172.30 j.gtld-servers.net. 172800 IN A 192.48.79.30 k.gtld-servers.net. 172800 IN A 192.52.178.30 l.gtld-servers.net. 172800 IN A 192.41.162.30 ;; Query time: 64 msec ;; SERVER: 198.41.0.4#53(a.root-servers.net) ;; WHEN: Mon Jan 31 09:22:17 2011 ;; MSG SIZE rcvd: 504 ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 12860 ;; flags: qr; QUERY: 1, ANSWER: 0, AUTHORITY: 2, ADDITIONAL: 2 ;; QUESTION SECTION: ;ignitemail.com. IN A ;; AUTHORITY SECTION: ignitemail.com. 172800 IN NS ns1.faithhiway.com. ignitemail.com. 172800 IN NS ns2.faithhiway.com. ;; ADDITIONAL SECTION: ns1.faithhiway.com. 172800 IN A 207.200.19.162 ns2.faithhiway.com. 172800 IN A 207.200.50.142 ;; Query time: 152 msec ;; SERVER: 192.54.112.30#53(h.gtld-servers.net) ;; WHEN: Mon Jan 31 09:22:17 2011 ;; MSG SIZE rcvd: 111 ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 43016 ;; flags: qr aa; QUERY: 1, ANSWER: 1, AUTHORITY: 2, ADDITIONAL: 2 ;; QUESTION SECTION: ;ignitemail.com. IN A ;; ANSWER SECTION: ignitemail.com. 3600 IN A 206.127.2.64 ;; AUTHORITY SECTION: ignitemail.com. 3600 IN NS ns1.faithhiway.com. ignitemail.com. 3600 IN NS ns2.faithhiway.com. ;; ADDITIONAL SECTION: ns1.faithhiway.com. 3600 IN A 206.127.2.71 ns2.faithhiway.com. 3600 IN A 206.127.2.72 ;; Query time: 25 msec ;; SERVER: 206.127.2.71#53(ns1.faithhiway.com) ;; WHEN: Mon Jan 31 09:22:18 2011 ;; MSG SIZE rcvd: 127 I really think this is a problem we have somewhere in our setup, but whether it is ignorance of something with DNS on my or my fellow engineer's end or just a dumb mistake we made, I have yet to find it.

    Read the article

  • Postfix 554 <[email protected]>: Relay access denied

    - by Matt
    So i am trying to set postfix up and I am running into some problems.....here is my files vim /etc/postfix/main.cf relayhost = [smtp.gmail.com]:587 smtp_connection_cache_destinations = smtp.gmail.com smtp_sasl_auth_enable=yes smtp_sasl_password_maps = hash:/etc/postfix/sasl_passwd smtp_sasl_tls_security_options = noanonymous tls_random_source = dev:/dev/urandom smtp_tls_CAfile= /etc/pki/CA/cacert.pem smtp_tls_security_level = may smtp_tls_scert_verifydepth = 9 append_dot_mydomain = no readme_directory = no myhostname = maggie.deliverypath.com alias_maps = hash:/etc/aliases alias_database = hash:/etc/aliases myorigin = /etc/mailname mydestination = maggie.deliverypath.com, localhost.deliverypath.com, , localhost mynetworks = 127.0.0.0/8 [::ffff:127.0.0.0]/104 [::1]/128 mailbox_size_limit = 0 recipient_delimiter = + inet_interfaces = all I also have the gmail password info vim /etc/postfix/sasl_passwd gmail-smtp.l.google.com [email protected]:somepass smtp.gmail.com [email protected]:somepass then I try to follow this article and i get this output telnet mail.demoslice.com 25 Trying 67.207.128.80... Connected to www.slicehost.com. Escape character is '^]'. 220 www.slicehost.com ESMTP Postfix (Ubuntu) HELO test.demoslice.com 250 www.slicehost.com MAIL FROM:<[email protected]> 250 Ok RCPT TO:<[email protected]> 554 <[email protected]>: Relay access denied its started service postfix start * Starting Postfix Mail Transport Agent postfix ...done. then the screen gets frozen and i cant do anything....any ideas

    Read the article

  • COM Object Method Invoke Exception - Silverlight 4

    - by Adam Driscoll
    I'm trying to use the new AutomationFactory provided with Silverlight 4 to call a .NET COM class. .NET COM-Exposed Class: public class ObjectContainer { public bool GetObject([Out, MarshalAs((UnmanagedType.IUnknown)] out object obj) { obj = new SomeOtherObj(); return true; } } Silverlight Assembly: dynamic objectContainer; try { objectContainer = AutomationFactory.GetObject(ProgId); } catch { objectContainer = AutomationFactory.CreateObject(ProgId); } object obj; if (!objectContainer.GetObject(out obj)) { throw new Exception(); } When I call objectContainer.GetObject(out obj) an exception is thrown stating: Value does not fall within the expected range. at MS.Internal.ComAutomation.ComAutomationNative.CheckInvokeHResult(UInt32 hr, String memberName, String exceptionSource, String exceptionDescription, String exceptionHelpFile, UInt32 exceptionHelpContext) at MS.Internal.ComAutomation.ComAutomationNative.Invoke(Boolean tryInvoke, String memberName, ComAutomationInvokeType invokeType, ComAutomationInteropValue[] rgParams, IntPtr nativePeer, ComAutomationInteropValue& returnValue) at MS.Internal.ComAutomation.ComAutomationObject.InvokeImpl(Boolean tryInvoke, String name, ComAutomationInvokeType invokeType, Object& returnValue, Object[] args) at MS.Internal.ComAutomation.ComAutomationObject.Invoke(String name, ComAutomationInvokeType invokeType, Object[] args) at System.Runtime.InteropServices.Automation.AutomationMetaObjectProvider.TryInvokeMember(InvokeMemberBinder binder, Object[] args, Object& result) at System.Runtime.InteropServices.Automation.AutomationMetaObjectProviderBase.<.cctorb__4(Object obj, InvokeMemberBinder binder, Object[] args) at CallSite.Target(Closure , CallSite , Object , String , Object& ) at CallSite.Target(Closure , CallSite , Object , String , Object& ) at ApplicationModule.ObjectContainer.GetObject() Wha's the deal?

    Read the article

  • Visual Studio 2010 64-bit COM Interop Issue

    - by Adam Driscoll
    I am trying to add a VC6 COM DLL to our VS2010RC C# solution. The DLL was compiled with the VC6 tools to create an x86 version and was compiled with the VC7 Cross-platform tools to generate a VC7 DLL. The x86 version of the assembly works fine as long as the consuming C# project's platform is set to x86. It doesn't matter whether the x64 or the x86 version of the DLL is actually registered. It works with both. If the platform is set to 'Any CPU' I receive a BadImageFormatException on the load of the Interop.<name>.dll. As for the x64 version, I cannot even get the project to build. I receive the tlbimp error: TlbImp : error TI0000: A single valid machine type compatible with the input type library must be specified. Has anyone seen this issue? EDIT: I've done a lot more digging into this issue and think this may be a Visual Studio bug. I have a clean solution. I bring in my COM assembly with language agnostic 'Any CPU' selected. The process architecture of the resulting Interop DLL is x86 rather than MSIL. May have to make the Interop by hand for now to get this to work. If anyone has another suggestion let me know.

    Read the article

  • Marshalling C# com items when using recursion

    - by Kevin
    I am using the SourceSafe COM object (SourceSafeTypeLib) from C# to automate a SourceSafe recursive get (part of a larger build process). The recursive function is shown below. How do I ensure that all the COM objects created in the foreach loop get released correctly? /// <summary> /// Recursively gets files/projects from SourceSafe (this is a recursive function). /// </summary> /// <param name="vssItem">The VSSItem to get</param> private void GetChangedFiles(VSSItem vssItem) { // 'If the object is a file perform the diff, // 'If not, it is a project, so use recursion to go through it if(vssItem.Type == (int)VSSItemType.VSSITEM_FILE) { bool bDifferent = false; //file is different bool bNew = false; //file is new //Surround the diff in a try-catch block. If a file is new(doesn't exist on //the local filesystem) an error will be thrown. Catch this error and record it //as a new file. try { bDifferent = vssItem.get_IsDifferent(vssItem.LocalSpec); } catch { //File doesn't exist bDifferent = true; bNew = true; } //If the File is different(or new), get it and log the message if(bDifferent) { if(bNew) { clsLog.WriteLine("Getting " + vssItem.Spec); } else { clsLog.WriteLine("Replacing " + vssItem.Spec); } string strGetPath = vssItem.LocalSpec; vssItem.Get(ref strGetPath, (int)VSSFlags.VSSFLAG_REPREPLACE); } } else //Item is a project, recurse through its sub items { foreach(VSSItem fileItem in vssItem.get_Items(false)) { GetChangedFiles(fileItem); } } }

    Read the article

< Previous Page | 7 8 9 10 11 12 13 14 15 16 17 18  | Next Page >