Search Results

Search found 5881 results on 236 pages for 'xor power'.

Page 11/236 | < Previous Page | 7 8 9 10 11 12 13 14 15 16 17 18  | Next Page >

  • Linux kernel regression on power usage

    - by dago
    Webupd8 reported this power management fix for the 2.6.38 Linux kernel regression: Add the following to the boot grub line "pcie_aspm=force" My question - how does this suggested fix differ from this hint from powertop: Suggestion: Enable Device Power Management by pressing the P key, which execute the following action: find /sys/devices/pci* -path "*power/control" -exec bash -c "echo auto > '{}'" \;

    Read the article

  • Tool to convert Textures to power of two?

    - by 3nixios
    I'm currently porting a game to a new platform, the problem being that the old platform accepted non power of two textures and this new platform doesn't. To add to the headache, the new platform has much less memory so we want to use the tools provided by the vendor to compress them; which of course only takes power of two textures. The current workflow is to convert the non power of tho textures to dds with 'texconv', then use the vendors compression tools in a batch. So, does anyone know of a tool to convert textures to their nearest 'power of two' counterparts? Thanks

    Read the article

  • Function Folding in #PowerQuery

    - by Darren Gosbell
    Originally posted on: http://geekswithblogs.net/darrengosbell/archive/2014/05/16/function-folding-in-powerquery.aspxLooking at a typical Power Query query you will noticed that it's made up of a number of small steps. As an example take a look at the query I did in my previous post about joining a fact table to a slowly changing dimension. It was roughly built up of the following steps: Get all records from the fact table Get all records from the dimension table do an outer join between these two tables on the business key (resulting in an increase in the row count as there are multiple records in the dimension table for each business key) Filter out the excess rows introduced in step 3 remove extra columns that are not required in the final result set. If Power Query was to execute a query like this literally, following the same steps in the same order it would not be overly efficient. Particularly if your two source tables were quite large. However Power Query has a feature called function folding where it can take a number of these small steps and push them down to the data source. The degree of function folding that can be performed depends on the data source, As you might expect, relational data sources like SQL Server, Oracle and Teradata support folding, but so do some of the other sources like OData, Exchange and Active Directory. To explore how this works I took the data from my previous post and loaded it into a SQL database. Then I converted my Power Query expression to source it's data from that database. Below is the resulting Power Query which I edited by hand so that the whole thing can be shown in a single expression: let     SqlSource = Sql.Database("localhost", "PowerQueryTest"),     BU = SqlSource{[Schema="dbo",Item="BU"]}[Data],     Fact = SqlSource{[Schema="dbo",Item="fact"]}[Data],     Source = Table.NestedJoin(Fact,{"BU_Code"},BU,{"BU_Code"},"NewColumn"),     LeftJoin = Table.ExpandTableColumn(Source, "NewColumn"                                   , {"BU_Key", "StartDate", "EndDate"}                                   , {"BU_Key", "StartDate", "EndDate"}),     BetweenFilter = Table.SelectRows(LeftJoin, each (([Date] >= [StartDate]) and ([Date] <= [EndDate])) ),     RemovedColumns = Table.RemoveColumns(BetweenFilter,{"StartDate", "EndDate"}) in     RemovedColumns If the above query was run step by step in a literal fashion you would expect it to run two queries against the SQL database doing "SELECT * …" from both tables. However a profiler trace shows just the following single SQL query: select [_].[BU_Code],     [_].[Date],     [_].[Amount],     [_].[BU_Key] from (     select [$Outer].[BU_Code],         [$Outer].[Date],         [$Outer].[Amount],         [$Inner].[BU_Key],         [$Inner].[StartDate],         [$Inner].[EndDate]     from [dbo].[fact] as [$Outer]     left outer join     (         select [_].[BU_Key] as [BU_Key],             [_].[BU_Code] as [BU_Code2],             [_].[BU_Name] as [BU_Name],             [_].[StartDate] as [StartDate],             [_].[EndDate] as [EndDate]         from [dbo].[BU] as [_]     ) as [$Inner] on ([$Outer].[BU_Code] = [$Inner].[BU_Code2] or [$Outer].[BU_Code] is null and [$Inner].[BU_Code2] is null) ) as [_] where [_].[Date] >= [_].[StartDate] and [_].[Date] <= [_].[EndDate] The resulting query is a little strange, you can probably tell that it was generated programmatically. But if you look closely you'll notice that every single part of the Power Query formula has been pushed down to SQL Server. Power Query itself ends up just constructing the query and passing the results back to Excel, it does not do any of the data transformation steps itself. So now you can feel a bit more comfortable showing Power Query to your less technical Colleagues knowing that the tool will do it's best fold all the  small steps in Power Query down the most efficient query that it can against the source systems.

    Read the article

  • CTP for Power View and SSAS Multidimensional Cubes

    - by Greg Low
    When Power View appeared, one of the big outcries was "but what about connecting to existing cubes!".Great to see that the SQL Server team have addressed that. A CTP that allows connecting Power View to SSAS Multidimensional cubes is now available:http://blogs.msdn.com/b/analysisservices/archive/2012/11/29/power-view-for-multidimensional-models-preview.aspxHelp the team get this out the door by trying it and providing feedback.

    Read the article

  • Ubuntu 12.04 does not power off

    - by G K
    I'm not able to power off Ubuntu, which was working fine a couple of days ago. When I click shut down, a blank screen appears and stays like that forever. It does not power off by itself and I'm forced to physically power off using the power button. I've even tried 'sudo shutdown now' and 'sudo shutdown -h now' and both don't seem to work! Please suggest some fix for this problem. Thanx in advance. Edit: Restart works fine. Also 'sudo poweroff' doesn't work!

    Read the article

  • Power View Infrastructure Configuration and Installation: Step-by-Step and Scripts

    This document contains step-by-step instructions for installing and testing the Microsoft Business Intelligence infrastructure based on SQL Server 2012 and SharePoint 2010, focused on SQL Server 2012 Reporting Services with Power View. This document describes how to completely install the following scenarios: a standalone instance of SharePoint and Power View with all required components; a new SharePoint farm with the Power View infrastructure; a server with the Power View infrastructure joined to an existing SharePoint farm; installation on a separate computer of client tools; installation of a tabular instance of Analysis Services on a separate instance; and configuration of single sign-on access for double-hop scenarios with and without Kerberos. Scripts are provided for all/most scenarios.

    Read the article

  • What actions does Ubuntu trigger when battery is low?

    - by blueyed
    When the battery is low, the screen gets dimmed after a few seconds already. This appears to be some special power-saving mode, and might be related to the time in org.gnome.settings-daemon.plugins.power.time-low (1200 seconds (20 minutes) the default). While this seems to get triggered by gnome-settings-daemon, I wonder what else Ubuntu does when this happens (e.g. via DBus listeners), or other event listeners that look for a "low battery" state. It seems like something in this regard causes Ubuntu / X / the system to behave more sluggish afterwards (when the laptop is on AC again), and I would like to look into what might be causing this. I could not find anything related via dconf-editor, e.g. in org.gnome.settings-daemon.plugins.power. It appears to get setup via idle_configure in plugins/power/gsd-power-manager.c, but it's probably something more related to something that listens on the DBus interface, which gets notified via e.g.: if (!g_dbus_connection_emit_signal (manager->priv->connection, NULL, GSD_POWER_DBUS_PATH, "org.freedesktop.DBus.Properties", "PropertiesChanged", props_changed, &error)) I could imagine that some "power saving" property gets set, but not unset when AC is available anymore and/or the battery is not low anymore. I have looked at the CPU governor setting (/sys/devices/system/cpu/cpu*/cpufreq/scaling_governor), but it was ondemand. I am using gnome-settings-daemon with awesomeWM on Ubuntu 14.04. gnome-settings-daemon=3.8.6.1-0ubuntu11.1 I've also compared gsd's plugins/power/gsd-power-manager.c with the one from Debian's gnome-settings-daemon-3.12.1, but could not find anything obvious that might have been fixed/changed in this regard. I have managed to trigger the gnome-power-manager's gnome-settings plugin (which dims the screen etc), by patching upower and use it after killing the system's upower daemon. (note that it's probably only energy that is being used by gpm to calculate it by itself). It does not make the system become sluggish.. OTOH I have not heard the speaker's beeping, which might come from the BIOS, which might be involved here, too - or other programs using the kernel's interface on /sys/class/power_supply/BAT0/. --- src/linux/up-device-supply.c.orig 2014-06-07 16:48:32.735920661 +0200 +++ src/linux/up-device-supply.c 2014-06-07 16:48:39.391920525 +0200 @@ -821,6 +821,9 @@ supply->priv->energy_old_first = 0; } + percentage = 3.1f; + time_to_empty = 3*60; + energy = 5; g_object_set (device, "energy", energy, "energy-full", energy_full,

    Read the article

  • Using an old PC case and power supply as a HDD Enclosure?

    - by mexiq
    I have 5 HDD and my computer is not handling the situation very well. hehe There are some towers that I can buy to put 4 of my drives out, but I'm thinking that I could use the power source of a failed computer I have and use it to power the 4 (or at least 3) of the drives. The data cables (SATA) will remain connected to the working computer (so no USB solution). The problem is that the power source will not work unless it is connected to the failing computer motherboard. Is there any way I could use the power source without plunging it to the old motherboard? Any "HOW-TO" links may be useful as well.

    Read the article

  • P4 vs. i3/i5 *T in power consumption and performance [migrated]

    - by Walter Zomb
    I am running an Intel P4 prescott with HT on my home server (linux file server on encrypted disks on software-RAID5 and virtualisation host for three further machines). The performance for this purpose is really okay. When the system is idle it consumes about 140W power. I am considering buying a new mainboard for an e.g. Intel i3-2100T or an Intel i5-2390T. Both are low power CPUs with a TDP about 40W. Has anyone experiences how much power a recent mainboard with one of these CPUs an 3-4 'green-energy' disks (6W each) consumes? Do I get underneath the 100W threshold? What's about the performance of these low power CPUs? Are they comparable to an Intel P4 with HT? regards, walter

    Read the article

  • Why does unpartitioned Hitachi HDS5C3020 drive start consuming 50% more power 15 minutes after boot?

    - by Pro Backup
    In a Debian 6.0.6 system there are 74 pieces of 2TB Toshiba DT01ABA200 drives. These drives are identified as Hitachi HDS5C3020BLE630 drives running firmware revision MZ4OAAB0. 64 Drives attached via HP SAS expander cards to an LSI 2008 SAS controller, another 5 drives are connected directly to the mainboard, 4 drives are connected to a Sil based PCI controller and last 1 drive is only powered and has no data cable connected. The controller LSI and Sil card's their onboard BIOS are both disabled and the mpt2sas and sata_sil modules are removed from the Linux debian 2.6.32-5-amd64 #1 SMP Sun Sep 23 10:07:46 UTC 2012 x86_64 GNU/Linux kernel. The mpt2sas module is loaded after boot using a modprobe command in /etc/rc.local. These 74 drives are not partitioned, neither formatted and also not mounted. The system consumes: with 0 drives: 70.6 - 70.9 Watt (also 15 minutes after boot); with 74 drives: 330 - 360 Watt, just after boot (is equivalent to 3.5 - 3.9W per drive in idle state); with 74 drives: 420 - 466 Watt, each time in the 15th minute of uptime (is equivalent to 4.7 - 5.3W per drive in idle state). The drive specification lists 4.7W as read/write, and 3.3W as idle power consumption. The increased power consumption is most likely on the 5V line, because after roughly 1 minute an "over current protection" (OCP) of the power supply (PSU) shuts down the power. The used PSU is a single rail model with an OCP of 122A on the 12V line and 55A on the 5V line. Regression: It doesn't matter whether the drive its APM value is set to disabled or 1 (maximum power saving). The operating system records no read/write activity in /proc/diskstats. The values there are identical (28 read, 0 write operations) as immediately after the modprobe operation. Can't test what happens when booting into the mainboard it's BIOS - to exclude any OS intervention - because the Super Micro X8SI6-F mainboard running firmware 06/27/12 has a bug that incorrectly reads a +74.0 C CPU sensor temperature as "High" in BIOS mode, and shuts down the power after 1 minute. What might be causing the drive read/write activity on all drives in the 15th minute after boot and how to prevent it from happening?

    Read the article

  • Is the APC BR700G UPS (or similar) compatible with Active PFC power supplies?

    - by David Zaslavsky
    I'm looking at getting a UPS for my home computer. So far the APC BR700G looks very promising, except for one thing: one of the reviews on Newegg says that this UPS does not work with a power supply with Active PFC. Pros: Unit looks great, built well, very heavy, was excited to use it. Cons: Didn't research enough - many newer power supplies like my corsair 750w (and yes dells and other mainstreamers sell them too) that I bought last year have a feature called active pfc (power factor corrected). The signal for this backup battery doesn't fully support that feature and can cause issues. You can find an article on APCs site if you search their user forums for PFC. And the power supply in my computer is, in fact, an Active PFC PSU. I've already found one answer on this site claiming that it's not an issue, that "most quality supplies these days have PFC and work just fine with a UPS." That disagrees with the review on Newegg. Can someone explain this discrepancy? Also, what is it exactly about a UPS that makes it incompatible with an Active PFC PSU? (if anything) Is there some way to tell based on the technical specifications, or do I just have to hunt for reviews online to avoid wasting my money? While any input would be appreciated, I would prefer to get an answer from someone with actual experience with similar UPS's and Active PFC power supplies, who can tell me whether it works or not.

    Read the article

  • Reseting Macbook Pro keyboard and trackpad's power usage on Windows?

    - by Dan the Man
    I recently installed a utitlity for Windows (ASUS Ai Charger) which modifies the USB ports on the computer to output more power (for charging iPads, etc). The problem is, I believe it is also giving more power to my keyboard and trackpad. And now, neither devices are working at all, yet they work on Mac OS X. So does anyone know the amount of power MacBook Pro (2007) keyboards and trackpads use, and how I can set these settings in Windows 7?

    Read the article

  • Suspected power supply issue? PC repeatedly whirs for some seconds and then dies.

    - by benwebdev
    I've come home today and switched on the PC I've built a few months ago only for the machine to whir for a few short seconds and then die. It repeats this until I disconnect the power lead. Nothing is output to the screen and this cut out happens very quickly after switching it on. What could this be and how could it be fixed? Is it the power supply? I'm in despair :-( My spec is below, everything is new and was bought and assembled within the last 6months, system has been fantastic until now. Power Supply: 620W CoolerMaster Real Power M620 Motherboard: Gigabyte GA-X58A-UD3R Intel X58 (Socket 1366) DDR3 Processor: Intel Core i7 930 2.80GHz @ 4.00GHz RAM: 6GB DDR3 OS Windows 7 64bit Sapphire HD 5770 Vapor-X 1GB Graphics card 1TB Hitachi HDD 720GB Seagate Barracuda HDD 350GB Seagate Barracuda HDD EMu 0404 PCI Soundcard D-Link PCI-E wireless card Samsung DVD RW drive

    Read the article

  • Is it safe to use an IDE to SATA power adapter for an extended period of time?

    - by qwertymk
    I just bought a computer from HP and they failed to include SATA power connectors with the power supply other then the one HD and DVD drive. Meanwhile I have two IDE to SATA power adapters that came with my "USB 2.0 to SATA/IDE cable" http://www.amazon.com/USB-2-0-SATA-Cable-Adapter/dp/B001OORN06 3rd pic on the left. I was wondering if I would just open up my computer and use it to plug it my SATA drives to the IDE power sources and mount it to the motherboard, would it damage my drives in the long run or have any other significant effects. A friend told me he knows people who have had their HD burn out because of this

    Read the article

  • What are the essential considerations for setting up systems in a location with unreliable power?

    - by dunxd
    I deal with a lot of remote offices located in parts of the world where the local grid power supply is unreliable. Power can go off anytime with no warning, with outages ranging from minutes to days Power fluctuation is wild, with spikes and brown outs Currently the offices will have some or all of the following: A generator, with an inverter, or some sort of manual switch A big UPS or battery array connecting a number of devices Several smaller APC UPS with computers attached Low cost Voltage Regulators sometimes connected between mains and UPS or device. I know that each of these things needs to be appropriately rated for the equipment to which it is connected (although I am not sure how to calculate the correct rating). The offices will generally have the following equipment (in varying quantities): some sort of internet connection device (VSAT router, ADSL modem, WiMax router) Cisco ASA 5505 firewall a bunch of PCs printers one server I don't seek to replace the advice of an electrician, but in some of these locations they only answer the questions you ask them, so I need to make sure I have enough understanding of the essentials to protect equipment from damage, and possibly get through some power cuts.

    Read the article

  • Will an Australian power adapter with an American plug charge a Laptop safely?

    - by leeand00
    A friend of mine has a laptop that she brought from Egypt to America, and she is afraid to charge it. She told me the laptop was purchased in Australia and it has a plug like this: And the power adapter reads The relevant text on the power brick reads: Wide Range Input 100-240V-1.7A(1.7A) 50-60Hz 18.5(18.5V) = 3.5A(3.5A) 65W The other end of the power adapter looks like this: Laptop make and model: HP Pavilion dv5-1045TX

    Read the article

  • power and modulo on the fly for big numbers

    - by user unknown
    I raise some basis b to the power p and take the modulo m of that. Let's assume b=55170 or 55172 and m=3043839241 (which happens to be the square of 55171). The linux-calculator bc gives the results (we need this for control): echo "p=5606;b=55171;m=b*b;((b-1)^p)%m;((b+1)^p)%m" | bc 2734550616 309288627 Now calculating 55170^5606 gives a somewhat large number, but since I have to do a modulooperation, I can circumvent the usage of BigInt, I thought, because of: (a*b) % c == ((a%c) * (b%c))%c i.e. (9*7) % 5 == ((9%5) * (7%5))%5 => 63 % 5 == (4 * 2) %5 => 3 == 8 % 5 ... and a^d = a^(b+c) = a^b * a^c, therefore I can divide b+c by 2, which gives, for even or odd ds d/2 and d-(d/2), so for 8^5 I can calculate 8^2 * 8^3. So my (defective) method, which always cut's off the divisor on the fly looks like that: def powMod (b: Long, pot: Int, mod: Long) : Long = { if (pot == 1) b % mod else { val pot2 = pot/2 val pm1 = powMod (b, pot, mod) val pm2 = powMod (b, pot-pot2, mod) (pm1 * pm2) % mod } } and feeded with some values, powMod (55170, 5606, 3043839241L) res2: Long = 1885539617 powMod (55172, 5606, 3043839241L) res4: Long = 309288627 As we can see, the second result is exactly the same as the one above, but the first one looks quiet different. I'm doing a lot of such calculations, and they seem to be accurate as long as they stay in the range of Int, but I can't see any error. Using a BigInt works as well, but is way too slow: def calc2 (n: Int, pri: Long) = { val p: BigInt = pri val p3 = p * p val p1 = (p-1).pow (n) % (p3) val p2 = (p+1).pow (n) % (p3) print ("p1: " + p1 + " p2: " + p2) } calc2 (5606, 55171) p1: 2734550616 p2: 309288627 (same result as with bc) Can somebody see the error in powMod?

    Read the article

  • With a typical USB hard drive enclosure, is the full range of drive power management functionality available?

    - by intuited
    In what may be an unrelated matter: is it possible to suspend a PC without unmounting an attached USB-powered drive, and then remounting it on resume? This is the behaviour I'm currently seeing (running Ubuntu linux 10.10). Are there certain models or brands that provide more complete control over this aspect of drive operation? My Friendly Neighbourhood Computer Store carries (part of) the Vantec Nexstar product line.

    Read the article

  • Must Keep the Power Flowing No Matter What! [Humorous Image]

    - by Asian Angel
    Who cares what it looks like as long as it works, right? Have you seen or created similar “quick fixes” to keep a computer running? Make sure to share your story in the comments! Barely Working Laptop Cord [Cheeseburger Network] 6 Ways Windows 8 Is More Secure Than Windows 7 HTG Explains: Why It’s Good That Your Computer’s RAM Is Full 10 Awesome Improvements For Desktop Users in Windows 8

    Read the article

  • ubuntu 12.04: Why my laptop is consuming more power than 11.10?

    - by sanz
    I had 11.10 X86 on my Asus laptop (sandybridge, Nvidia 520M). I had 8 hours' battery life with Bumblebee and Jupiter. Average battery discharge rate was around 10w. Later I changed, not upgraded, to 12.04.1 AMD64. I installed Jupiter. But there is no "restricted drivers" available so I guess Bumblebee will not work. So I removed nvidia drivers. Now I only get 4 hours' battery life. Average battery discharge rate is around 19w. The removal of nvidia driver did not make any difference. What's the cause? Nvidia video card not disabled or 64b version of Ubuntu?

    Read the article

  • How to turn off power management for external hard drive (Seagate GoFlex)?

    - by RPG Master
    I bought this 2tb Segate GoFlex this last Black Friday and since then every 15 minutes or so the drive spins down, and then a little while later completely dismounts. Very annoying. From what I understand you could turn this off using the including Windows and Mac only software. This function and what controls it isn't proprietary, right? There has to be something that'll let me set it in Ubuntu... Anyone have any suggestions? Also, I formatted it to EXT4. Hope I didn't screw myself up. :/

    Read the article

  • Computer turns off and on after start ..then goes dead

    - by Shiki
    I built a new PC from the following components: - CPU: Intel Core i7 950 - MB: Gigabyte X58A-UD3R - RAM: 2x2gb i7 Corsair memory - VGA: Zotac AMP2 GTX260 - HDD: 1 GreenSATA HDD (Western Digital 500gb RE2) When I turn it on, it goes for a few seconds, fans at maximum speed, then turns off. The again, it starts by itself.. and goes with fans on max speed, nothing happens. First I suspected my PSU. It's a Chieftec 450AA PSU. After I borrowed a Chieftec 550AA PSU, I tried to start with that. Exact same story. Any idea ? Do I need a bigger PSU? Reason why its not localized. I never seen this turn on, off, on. If you give answer for that, it would already help people like me, with the same problem.

    Read the article

  • (Why) are IEC C5/C6 connectors a necessity? Why not use C13/C14?

    - by Mike
    That's a question I was asking myself the first time I saw such a weird C5 plug. That was a while ago, but I came across it again and haven't found an answer yet. The only thing I could find out is that C5 is with 2.5A and C13 with 10A. But I guess it would technically be no problem building an AC adapter (e.g. for laptops) in which you plug the far more common C13 connector. http://en.wikipedia.org/wiki/IEC_connector

    Read the article

  • Adding XOR function to bigint library

    - by Jason Gooner
    Hi, I'm using this Big Integer library for Javascript: http://www.leemon.com/crypto/BigInt.js and I need to be able to XOR two bigInts together and sadly the library doesn't include such a function. The library is relatively simple so I don't think it's a huge task, just confusing. I've been trying to hack one together but not having much luck, would be very grateful if someone could lend me a hand. This is what I've attempted (might be wrong). But im guessing the structure is going to be quite similar to some of the other functions in there. function xor(x, y) { var c, k, i; var result = new Array(0); // big int for result k=x.length>y.length ? x.length : y.length; // array length of the larger num // Make sure result is the correct array size? maybe: result = expand(result, k); // ? for (c=0, i=0; i < k; i++) { // Do some xor here } // return the bigint xor result return result; } What confuses me is I don't really understand how it stores numbers in the array blocks for the bigInt. I don't think it's a case of simply bigintC[i] = bigintA[i] ^ bigintB[i], then most other functions have some masking operation at the end that I don't understand. I would really appreciate any help getting this working. Thanks

    Read the article

< Previous Page | 7 8 9 10 11 12 13 14 15 16 17 18  | Next Page >