  • Unable to debug XBAP with Visual Studio 2010

    - by Oleg I.
    Just migrated my project to Visual Studio 2010, but target framework was left 3.5. Project contains an XBAP app in partial trust and a bunch of WCF services. Debugging is configured to start PresentationHost.exe with -debug and -debugSecurityZoneUrl parameters. Under VS2008 everything works fine, and in VS2010 Beta2 (don't sure about RC), but under VS2010 RTM debugging is for some reason doesn't working. Application runs, but doesn't hit any breakpoint. And if for example exception occurs, message box appears "Do you wish to debug or close..." and after I choose "debug" option new weird message box appears: --------------------------- Warning --------------------------- A debugger is attached to PresentationHost.exe but not configured to debug this unhandled exception. To debug this exception, detach the current debugger. An unhandled exception was raised from Microsoft .NET Framework v 1.0, 1.1, or 2.0, but the current debugger is configured to debug Microsoft .NET Framework v4.0 code. Examine the exception using the SOS tool. --------------------------- OK --------------------------- And where is the vaunted multitargeting? Did anyone have already bumped into same issue? UPDATE: Tried to debug with "Start browser with URL" option. Debugging is working, but I get SecurityException. So it is possible, just need to figure out how to make it work with "Start external program" option. UPDATE2: Checked what PresentationHost is actually loads in both scenarios: "Start external program" - Latest version (4.0.31106.0) from C:\Windows\System32\ "Start browser with URL" - Old version (3.0.6920.4902) from C:\Windows\winsxs\x86_wpf-presentationhostexe_31bf3856ad364e35_6.1.7600.16385_none_6fca8974817173aa

    Read the article

  • Has anyone installed NServiceBus onto a Microsoft clustered server?

    - by David
    I am trying to install NServiceBus onto a clustered win2k3 host. The configuration utility provided (runner.exe) throw some errors that I did not catch, and it now runs correctly. When running NServiceBus.Host.exe i am get this error repeatedly: System.Transactions.TransactionAbortedException: The transaction has aborted. --- System.Transactions.TransactionManagerCommunicationException: Communication with the underlying transaction manager has failed. --- System.Runtime.InteropServices.COMException (0x8004D01B): The Transaction Manager is not available. (Exception from HRESULT: 0x8004D01B) at System.Transactions.Oletx.IDtcProxyShimFactory.ConnectToProxy(String nodeName, Guid resourceManagerIdentifier, IntPtr managedIdentifier, Boolean& nodeNameMatches, UInt32& whereaboutsSize, CoTaskMemHandle& whereaboutsBuffer, IResourceManagerShim& resourceManagerShim) at System.Transactions.Oletx.DtcTransactionManager.Initialize() --- End of inner exception stack trace --- at System.Transactions.Oletx.OletxTransactionManager.ProxyException(COMException comException) at System.Transactions.Oletx.DtcTransactionManager.Initialize() at System.Transactions.Oletx.DtcTransactionManager.get_ProxyShimFactory() at System.Transactions.Oletx.OletxTransactionManager.CreateTransaction(TransactionOptions properties) at System.Transactions.TransactionStatePromoted.EnterState(InternalTransaction tx) --- End of inner exception stack trace --- at System.Transactions.TransactionStateAborted.CheckForFinishedTransaction(InternalTransaction tx) at System.Transactions.EnlistableStates.Promote(InternalTransaction tx) at System.Transactions.Transaction.Promote() at System.Transactions.TransactionInterop.ConvertToOletxTransaction(Transaction transaction) at System.Transactions.TransactionInterop.GetDtcTransaction(Transaction transaction) at System.Messaging.MessageQueue.StaleSafeReceiveMessage(UInt32 timeout, Int32 action, MQPROPS properties, NativeOverlapped* overlapped, ReceiveCallback receiveCallback, CursorHandle cursorHandle, IntPtr transaction) at System.Messaging.MessageQueue.ReceiveCurrent(TimeSpan timeout, Int32 action, CursorHandle cursor, MessagePropertyFilter filter, MessageQueueTransaction internalTransaction, MessageQueueTransactionType transactionType) at System.Messaging.MessageQueue.Receive(TimeSpan timeout, MessageQueueTransactionType transactionType) at NServiceBus.Unicast.Transport.Msmq.MsmqTransport.ReceiveMessageFromQueueAfterPeekWasSuccessful() in d:\BuildAgent-02\work\672d81652eaca4e1\src\impl\unicast\NServiceBus.Unicast.Msmq\MsmqTransport.cs:line 551 Has anyone successfully put NServiceBus onto a clustered server, if so, how did you get it working?

    Read the article

  • How to Compile Mod_Python 3.3.1 for Python 2.6 and Apache 2.2 on Windows?

    - by John
    I have no experience compiling code other than using Visual Studio's Build command. I am hoping we can create a step by step guide for compiling mod_python on windows. Please be as descriptive as possible. This is what I've done so far: Download and install python 2.6.2 Download and install apache 2.2.11 Download the most recent source code for mod_python from svn From here I'm lost to what the next step is. I've downloaded Microsoft Visual C++ 2008 Express Edition. As mentioned by Hao I've already tried the tutorial mentioned in that link. Here is the error messages I'm receiving with that tutorial. C:\mod_python\distbuild_installer.bat Could Not Find C:\mod_python\src*.obj running bdist_wininst running build running build_py creating build creating build\lib.win32-2.6 creating build\lib.win32-2.6\mod_python copying C:\mod_python\lib\python\mod_python\apache.py - build\lib.win32-2.6\mod _python copying C:\mod_python\lib\python\mod_python\cache.py - build\lib.win32-2.6\mod_ python copying C:\mod_python\lib\python\mod_python\cgihandler.py - build\lib.win32-2.6 \mod_python copying C:\mod_python\lib\python\mod_python\Cookie.py - build\lib.win32-2.6\mod _python copying C:\mod_python\lib\python\mod_python\importer.py - build\lib.win32-2.6\m od_python copying C:\mod_python\lib\python\mod_python\psp.py - build\lib.win32-2.6\mod_py thon copying C:\mod_python\lib\python\mod_python\publisher.py - build\lib.win32-2.6\ mod_python copying C:\mod_python\lib\python\mod_python\python22.py - build\lib.win32-2.6\m od_python copying C:\mod_python\lib\python\mod_python\Session.py - build\lib.win32-2.6\mo d_python copying C:\mod_python\lib\python\mod_python\testhandler.py - build\lib.win32-2. 6\mod_python copying C:\mod_python\lib\python\mod_python\util.py - build\lib.win32-2.6\mod_p ython copying C:\mod_python\lib\python\mod_python__init__.py - build\lib.win32-2.6\m od_python running build_ext building 'mod_python_so' extension creating build\temp.win32-2.6 creating build\temp.win32-2.6\Release creating build\temp.win32-2.6\Release\mod_python creating build\temp.win32-2.6\Release\mod_python\src C:\Program Files\Microsoft Visual Studio 9.0\VC\BIN\cl.exe /c /nologo /Ox /MD /W 3 /GS- /DNDEBUG -DWIN32 -DNDEBUG -D_WINDOWS -IC:\mod_python\src\include -Ic:\apa che\include -IC:\Python26\include -IC:\Python26\PC /TcC:\mod_python\src\mod_pyth on.c /Fobuild\temp.win32-2.6\Release\mod_python\src\mod_python.obj mod_python.c c:\apache\include\ap_config.h(25) : fatal error C1083: Cannot open include file: 'apr.h': No such file or directory error: command '"C:\Program Files\Microsoft Visual Studio 9.0\VC\BIN\cl.exe"' fa iled with exit status 2

    Read the article

  • How to solve "catastrophic failure" with 32-bit COM component in SysWOW64\cscript or wscript

    - by kcrumley
    I'm trying to run a VBScript script that uses a 7-year-old 3rd-party 32-bit COM component on Windows Server 2008 R2, with the command-line 32-bit script host, SysWOW64\cscript.exe. When I call CreateObject on the class, it appears to be successful, but the very first time I try to use a property or method (I've tried several different ones) on the object, it gives me the "catastrophic failure". I have identical results with SysWOW64\wscript.exe, except, of course, that my error message comes in a msgbox instead of the command-line window. I think this has to do specifically with the 64-bit scripting hosts because of the following: The equivalent Classic ASP script, calling the same component and using 95% of the same code, works correctly on the same server, with IIS configured to support 32-bit COM. The same VBScript works correctly on a 32-bit Windows XP machine and a 32-bit Windows Server 2003 machine. The component fails in exactly the same way on my 64-bit Windows 7 machine. My Google searches for solutions to this problem have mostly turned up a lot of different problems that were solved by putting the COM component into a toolbar in Visual Studio. Obviously, that solution doesn't apply here. My questions are: Is there a core problem that is always behind a "catastrophic failure" from a Windows scripting host calling a COM component? Is there a place in a configuration snap-in, or in the registry, where I need to make a change similar to the change I had to make to the IIS Application pool to "Enable 32-bit Applications"? Is there a general place in the Server 2008 R2 Event Viewer that I should be looking, to see if there are any more details on the failure, in case it turns out to be specific to this component? Thanks in advance.

    Read the article

  • ServiceRoute + WebServiceHostFactory kills WSDL generation? How to create extensionless WCF service

    - by Ethan J. Brown
    I'm trying to use extenionless / .svc-less WCF services. Can anyone else confirm or deny the issue I'm experiencing? I use routing in code, and do this in Application_Start of global.asax.cs: RouteTable.Routes.Add(new ServiceRoute("Data", new WebServiceHostFactory(), typeof(DataDips))); I have tested in both IIS 6 and IIS 7.5 and I can use the service just fine (ie my extensionless handler is correctly configured for ASP.NET). However, metadata generation is totally screwed up. I can hit my /mex endpoint with the WCF Test Client (and I presume svcutil.exe) -- but the ?wsdl generation you typically get with .svc is toast. I can't hit it with a browser (get 400 bad request), I can't hit it with wsdl.exe, etc. Metadata generation is configured correctly in web.config. This is a problem of course, because the service is exposed as basicHttpBinding so that an old style ASMX client can get to it. But of course, the client can't generate the proxy without a WSDL description. If I instead use serviceActivation routing in config like this, rather than registering a route in code: <serviceHostingEnvironment aspNetCompatibilityEnabled="true"> <serviceActivations> <add relativeAddress="Data.svc" service="DataDips" /> </serviceActivations> </serviceHostingEnvironment> Then voila... it works. But then I don't have a clean extensionless url. If I change relativeAddress from Data.svc to Data, then I get a configuration exception as this is not supported by config. (Must use an extension registered to WCF). I've also attempted to use this code in conjunction with the above config: RouteTable.Routes.MapPageRoute("","Data/{*data}","~/Data.svc/{*data}",false); My thinking is that I can just point the extensionless url at the configured .svc url. This doesn't work -- the /Data.svc continues to work, but /Data returns a 404. Anyone with any bright ideas?

    Read the article

  • Invoking brill tagger through C#

    - by Toshal Mokadam
    We want to use brill tagger such that on a button click, it will tag the Input.txt into output.txt. So we have created a new visual studio project and put a button. On button click event we wrote the following code. There are no errors and we can see the command prompt getting invoked. But the output file is not getting created. The code is as follows. could you pls guide us?? private void button1_Click(object sender, EventArgs e) { ProcessStartInfo brillStartInfo = new ProcessStartInfo(@"C:\Users\toshal\Documents\Visual Studio 2008\Projects\brill tagger\bin\brill.exe"); brillStartInfo.Arguments = "/C brill.exe LEXICON.BROWN Input.txt BIGRAMS LEXICALRULEFILE.BROWN CONTEXTUALRULEFILE.BROWN > output.txt"; brillStartInfo.UseShellExecute = false; brillStartInfo.RedirectStandardOutput = true; brillStartInfo.RedirectStandardError = true; brillStartInfo.CreateNoWindow = false; Process brill = new Process(); brill.StartInfo = brillStartInfo; brill.Start(); string output = brill.StandardOutput.ReadToEnd(); brill.WaitForExit(); }

    Read the article

  • what can be causes of http server crash?

    - by mithunmo
    Hello , I am using WAMP server on Windows XP. - Apache 2.2.11 - MySQL 5.1.36 (INNODB engine) - PHP 5.3.0 I observe that my WAMP server crashes in the following scenarios 1) IF I use a Low end PC ( low processor speed and low RAM) 2) After making some changes to httpd.conf file .For eg changing the Allow from IP address . But here it crashes only once and then it starts to work fine. 3) Random crashes CRASH LOG szAppName : httpd.exe szAppVer : 2.2.11.0 szModName : php5ts.dll szModVer : 5.3.0.0 offset : 0000c309 C:\DOCUME~1\blrcom\LOCALS~1\Temp\WERc677.dir00\httpd.exe.mdmp C:\DOCUME~1\blrcom\LOCALS~1\Temp\WERc677.dir00\appcompat.txt My questions 1) Does high CPU utilization/LOW RAM can also cause the HTTP server to crash ? 2) excessive file reading as in every 10 seconds ? 3) unlimited script execution time . I have set the maximum execution time in php script to 0 as my script has to execute for sometimes 2-3 days. Is there any way to avoid this ? 4) Access to Database ? Should we use lock before reading and writing Can these be the reasons for random wamp server crashes ? OR is is some other programming error ? Please guide me . Regards, Mithun

    Read the article

  • Extracting files from merge module

    - by Mystagogue
    All I want is a command-line tool that can extract files from a merge module (.msm) onto disk. I'm trying msidb.exe and orca.exe The documentation for orca states: Many merge module options can be specified from the command line... Extracting Files from a Merge Module Orca supports three different methods for extracting files contained in a merge module. Orca can extract the individual CAB file, extract the files into a module tree and extract the files into a source image once it has been merged into a target database... Extracting Files To extract the individual files from a merge module, use the ... -x ... option on the command line, where is the desired path to the new directory tree. The specified path is used as the root path for the extracted files. All files are extracted from the CAB file embedded in the module and placed in the specified path. The directory layout for the extracted files is based on the directory tree of the merge module. It mostly sounds like exactly what I need. But when I try it, orca simply opens up an editor (with info on the msm I specified) and then does nothing. I've tried a variety of command lines, usually starting with this: orca -x theDirectory theModule.msm I use "theDirectory" as whatever empty folder I want. Like I said - it didn't do anything. Then I tried msidb, where a couple of attempts I've made look like this: msidb -d theModule.msm -w {storage} msidb -d theModule.msm -x {stream} In both cases, I don't know what to insert for {storage} or {stream} to make it happy - I don't know what those represent. Can someone explain what I'm doing wrong with the command line options? Is there any other tool that can do this?

    Read the article

  • Open mails in outlook from java using the protocol "mapi://"

    - by Goulutor
    I developp a Java application using Windows Desktop Search from which I can retrieve some information about files on my computer such as urls (System.ItemUrl). An example of such url is file://c:/users/ausername/documents/aninterestingfile.txt for "normal" files. This field give also urls of mail items indexed from Outlook or Thunderbird. Thunderbird's items (only available using vista and seven) are also files (.wdseml). But outlook's items urls start with "mapi://" like : mapi://{S-1-5-21-1626573300-1364474481-487586288-1001}/[email protected]($b423dcd5)/0/Inbox/???????????????????????? The problem I have is opening the real item from Java in Outlook using this url. If I copy/paste it in the run dialog of Windows, it works ; it also works if I use "start" followed by the copied/pasted url in command line. The url seems to be encoded in UTF-16. I want to be able to write such code : String url = "mapi://{S-1-5-21-1626573300-1364474481-487586288-1001}/[email protected]($b423dcd5)/0/Inbox/????????????????????????"; Runtime.getRuntime().exec("cmd.exe /C start " + url); I doesn't work and I've tried other solutions like : String start = "start"; String url = "mapi://{S-1-5-21-1626573300-1364474481-487586288-1001}/[email protected]($b423dcd5)/0/Inbox/????????????????????????"; FileOutputStream fos = new FileOutputStream(new File("test.bat"); fos.write(start.getBytes("UTF16"); fos.write(url.getBytes("UTF16")); fos.close(); Runtime.getRuntime().exec("cmd.exe /C test.bat"); without any success. Using the solution above, the file "test.bat" contains the correct url and the "start" command, but the run of "test.bat" results in the well known error message : '¦' is not recognized as an internal or external command, operable program or batch file. Has anybody an idea to be able to open "mapi://" items from Java ?

    Read the article

  • Command-Line Parsing API from TestAPI library - Type-Safe Commands how to

    - by MicMit
    Library at http://testapi.codeplex.com/ Excerpt of usage from http://blogs.msdn.com/ivo_manolov/archive/2008/12/17/9230331.aspx A third common approach is forming strongly-typed commands from the command-line parameters. This is common for cases when the command-line looks as follows: some-exe COMMAND parameters-to-the-command The parsing in this case is a little bit more involved: Create one class for every supported command, which derives from the Command abstract base class and implements an expected Execute method. Pass an expected command along with the command-line arguments to CommandLineParser.ParseCommand – the method will return a strongly-typed Command instance that can be Execute()-d. // EXAMPLE #3: // Sample for parsing the following command-line: // Test.exe run /runId=10 /verbose // In this particular case we have an actual command on the command-line (“run”), which we want to effectively de-serialize and execute. public class RunCommand : Command { bool? Verbose { get; set; } int? RunId { get; set; } public override void Execute() { // Implement your "run" execution logic here. } } Command c = new RunCommand(); CommandLineParser.ParseArguments(c, args); c.Execute(); ============================ I don't get if we instantiate specific class before parsing arguments , what's the point of command line argument "run" which is very first one. I thought the idea was to instantiate and execute command/class based on a command line parameter ( "run" parameter becomes instance RunCommand class, "walk" becomes WalkCommand class and so on ). Can it be done with the latest version ?

    Read the article

  • Need help modifying C++ application to accept continuous piped input in Linux

    - by GreeenGuru
    The goal is to mine packet headers for URLs visited using tcpdump. So far, I can save a packet header to a file using: tcpdump "dst port 80 and tcp[13] & 0x08 = 8" -A -s 300 | tee -a ./Desktop/packets.txt And I've written a program to parse through the header and extract the URL when given the following command: cat ~/Desktop/packets.txt | ./packet-parser.exe But what I want to be able to do is pipe tcpdump directly into my program, which will then log the data: tcpdump "dst port 80 and tcp[13] & 0x08 = 8" -A -s 300 | ./packet-parser.exe Here is the script as it is. The question is: how do I need to change it to support continuous input from tcpdump? #include <boost/regex.hpp> #include <fstream> #include <cstdio> // Needed to define ios::app #include <string> #include <iostream> int main() { // Make sure to open the file in append mode std::ofstream file_out("/var/local/GreeenLogger/url.log", std::ios::app); if (not file_out) std::perror("/var/local/GreeenLogger/url.log"); else { std::string text; // Get multiple lines of input -- raw std::getline(std::cin, text, '\0'); const boost::regex pattern("GET (\\S+) HTTP.*?[\\r\\n]+Host: (\\S+)"); boost::smatch match_object; bool match = boost::regex_search(text, match_object, pattern); if(match) { std::string output; output = match_object[2] + match_object[1]; file_out << output << '\n'; std::cout << output << std::endl; } file_out.close(); } } Thank you ahead of time for the help!

    Read the article

  • CCNet: "Failing Tasks : FilteredSourceControl: CheckForModifications" error

    - by Marc
    I've installed CCNet and now I'm trying to set up a link to our repository. When I visit the CCNet dashboard website the project shows up ok, but when I click the Force button I receive this error in the messages column: Failing Tasks : FilteredSourceControl: CheckForModifications If I log into the server as the account which I've specified CCNet should use to connect to the repository, and do an Update on the project by hand (i.e. using SVN.exe or TortoiseSVN) the update works fine. My sourcecontrol section of the CCNet.config file is below. <sourcecontrol type="filtered"> <sourceControlProvider type="svn" autoGetSource="true"> <executable>E:\SVNServer\bin\svn.exe</executable> <trunkUrl> https://bserver.int:4443/trunk </trunkUrl> <workingDirectory>E:\buildserver</workingDirectory> <username>USER</username> <password>PASSWORD</password> </sourceControlProvider> <inclusionFilters> <pathFilter> <pattern>**/*.*</pattern> </pathFilter> </inclusionFilters> </sourcecontrol> Both the cruisecontrol.net website and google seem utterly devoid of any information on this error, other than that it probably relates to the inclusionfilter section in the block above. Can anyone provide any ideas?

    Read the article

  • VS2010 / Target Framework = 3.5 / Building on Continuous Integration Server

    - by granadaCoder
    I'm checking into upgrading to VS2010. Our production servers only have 3.5 Framework and it will be 6-9 months before they are updated. We also have a Continuous Integration Server, running CruiseControl.NET (CC.NET). It has the 3.5 Framework on it as well. Our implementation of CC.NET mainly calls msbuild.exe MySolution.msbuild. (We encapsulate most of the build logic into .msbuild files fyi) Inside the .msbuild file, the following is the "Build" syntax: < Target Name="Build" DependsOnTargets="Checkout" < MSBuild Projects="$(WorkingCheckout)\MySolution.sln" Targets="Build" Properties="Configuration=$(Configuration)" < Output TaskParameter="TargetOutputs" ItemName="TargetOutputsItemName"< /Output < /MSBuild < /Target (A few spaces added to make it display here) =========== I know the VS2010 can "Target" the 3.5 Framework. My question is what happens when I have a VS2010 dev machine, and I check the VS2010 .sln and .csproj(s) files into source control (svn, btw).....will the CC.NET machine ~~which only have the 3.5 Framework installed on it........be able to build the .sln ? I guess I could test it, but the catch22 is that I don't have VS2010 (yet). So I'm asking before I try (the trial or a real install. ............. Any ideas what will happen? I guess the crux question is, what will happen. c:\WINDOWS\Microsoft.NET\Framework\v3.5\MSBuild.exe "MyVS2010SolutionFile.sln" ?? My hopeful goal would be, allow the developers to have VS2010 (now!), and it still be "ok" for the CC.NET machine and the Production Servers which will only have the 3.5 Framework on them for the foreseeable future. Just to be clear, developers NEVER create deployable builds. Only the CC.NET machine produces builds that will be pushed as production builds. Any help?

    Read the article

  • Runtime Version of ILMerge'd assembly is v4.0.20926; expected version is v4.0.30319

    - by Sam
    This is what my .csproj AfterBuild looks like: <Target Name="AfterBuild" Condition=" '$(Configuration)' == 'Release'"> <Exec Command="&quot;..\Tools\ILMerge\ILMerge.exe&quot; /internalize /ndebug /out:@(MainAssembly) /targetplatform:v4,C:\Windows\Microsoft.NET\Framework\v4.0.30319 &quot;@(IntermediateAssembly)&quot; @(ReferenceCopyLocalPaths->'&quot;%(FullPath)&quot;', ' ')" Condition=" '$(TargetFrameworkVersion)' == 'v4.0'" /> </Target> I'm running 64-bit Windows. I have tried changing the .NET Framework from ...\Microsoft.NET\Framework\... to ...\Microsoft.NET\Framework64\... but it didn't help. I also created ILMerge.exe.config in the ILMerge directory: <?xml version ="1.0"?> <configuration> <startup useLegacyV2RuntimeActivationPolicy="true"> <requiredRuntime safemode="true" imageVersion="v4.0.30319" version="v4.0.30319"/> </startup> </configuration> Why isn't ILMerge generating a 4.0.30319 assembly?

    Read the article

  • SQL Compact error: Unable to load DLL 'sqlceme35.dll'. The specified module could not be found

    - by Ciaran Bruen
    Hi - I'm developing a Winforms application using Visual Studio 2008 C# that uses a SQL compact 3.5 database on the client. The client will most likely be 32 bit XP or Vista machines. I'm using a standard Windows Installer project that creates an msi file and setup.exe to install the app on a client machine. I'm new to SQL compact so I haven't had to distribute a client database like this before now. When I run the setup.exe (on new Windows XP 32 bit with SP2 and IE 7) it installs fine but when I run the app I get the error below: Unable to load DLL 'sqlceme35.dll'. The specified module could not be found I spent a few hours searching this error already but all I can find are issues relating to installing on 64 bit Windows, none relating to normal 32 bit that I'm using. The install app copies the all the dependant files that it found into the specified install directory, including the System.Data.SqlServerCe.dll file (assembly version 3.5.1.0). The database file is in a directory called 'data' off the application directory, and the connection string for it is <add name="Tickets.ieOutlet.Properties.Settings.TicketsLocalConnectionString" connectionString="Data Source=|DataDirectory|\data\TicketsLocal.sdf" providerName="Microsoft.SqlServerCe.Client.3.5" /> Some questions I have: should the app be able to find the dll if it's in the same directory i.e. local to the app, or do I need to install it in the GAC? (If so cam I use the Windows Installer to install a dll in the GAC?) is there anything else I need to distribute with the app in order to use a Sql Compact database? there are other dlls also such as MS interop for exporting data to Excel on the client. Do these need to be installed in the GAC or will locating them in the application directory suffice? TIA, Ciaran.

    Read the article

  • Spaces and backslashes in Visual Studio build events

    - by gencha
    I have an application that is supposed to aid my project in terms of pre- and post-build event handling. I'm using ndesk.options for command line argument parsing. Which gave me weird results when my project path contains spaces. I thought this was the fault of ndesk.options but I guess my own application is to blame. I call my application as a post-built event like so: build.exe --in="$(ProjectDir)" --out="c:\out\" A simple foreach over args[] displays the following: --in=c:\my project" --out=c:\out" What happened is that the last " in each parameter was treated as if it was escaped. Thus the trailing backslash was removed. And the whole thing is treated as a single argument. Now I thought I was being smart by simply escaping the first " as well, like so: build.exe --in=\"$(ProjectDir)" --out=\"c:\out\" In that case the resulting args[] look like this: --path="c:\my project" --out="c:\out" The trailing backslash in the parameters is still swallowed and the first parameter is now split up. Passing this args[] to ndesk.options will then yield wrong results. How should the right command line look so that the correct elements end up in the correct args[] slots? Alternatively, how is one supposed to parse command line arguments like these with or without ndesk.options? Any suggestion is welcome. Thanks in advance

    Read the article

  • Error Building Gem

    - by Joel M.
    I tried to install the following gem: http://github.com/maxjustus/sinatra-authentication on Windows 7 running Ruby 1.9 from the One-Click Installer. I got the following error: Microsoft Windows [Version 6.1.7600] Copyright (c) 2009 Microsoft Corporation. All rights reserved. C:\Users\Joel>gem install sinatra-authentication Building native extensions. This could take a while... ERROR: Error installing sinatra-authentication: ERROR: Failed to build gem native extension. C:/Ruby19/bin/ruby.exe extconf.rb creating Makefile make 'make' is not recognized as an internal or external command, operable program or batch file. Gem files will remain installed in C:/Ruby19/lib/ruby/gems/1.9.1/gems/yajl-ruby- 0.7.5 for inspection. Results logged to C:/Ruby19/lib/ruby/gems/1.9.1/gems/yajl-ruby-0.7.5/ext/gem_mak e.out I looked everywehere online, tried to install earlier versions, and attempted a manual install without success (it gave me a stack too deep error). I suspect there are problems with the yajl-ruby gem (http://github.com/brianmario/yajl-ruby), a dependency? (I think) The logs in gem_make.out show: C:/Ruby19/bin/ruby.exe extconf.rb creating Makefile make 'make' is not recognized as an internal or external command, operable program or batch file. Do you have any idea as to how to solve this? Thanks!

    Read the article

  • C# unit test code questions continue

    - by 5YrsLaterDBA
    more questions after questions in here: http://stackoverflow.com/questions/2714073/c-unit-test-code-questions I found the VS unit test testframe treat private and protected method in the same way but deferent with public method. The following is the generated code for a private method: /// <summary> ///A test for recordLogin ///</summary> [TestMethod()] [DeploymentItem("SystemSoftware.exe")] public void recordLoginTest() { User_Accessor target = new User_Accessor(); // TODO: Initialize to an appropriate value Guid userId = new Guid(); // TODO: Initialize to an appropriate value string action = string.Empty; // TODO: Initialize to an appropriate value Users user = null; // TODO: Initialize to an appropriate value AndeDBEntities db = null; // TODO: Initialize to an appropriate value bool expected = false; // TODO: Initialize to an appropriate value bool actual; actual = target.recordLogin(userId, action, user, db); Assert.AreEqual(expected, actual); Assert.Inconclusive("Verify the correctness of this test method."); } questions: [DeploymentItem("SystemSoftware.exe")] is for private and protected methods, why needs it and what is it for? In my original class/file, if I point to the original method and try to "Find All References". The reference in the unit test class/file will not show up for private and protected methods but it will show up for all public methods. Why is that? Is it right? 3.

    Read the article

  • Visual Studio 2008 project organization for executable and assembly

    - by user304582
    Hi - I am having a problem setting up the following in Visual Studio 2008: a parent project which includes the entrypoint Main() method class and which declares an interface, and a child project which has classes that implement the interface declared in the parent project. I have specified that Parent's Output type is a Console application, and Child's Output type is a Class library. In Child I have add a reference to the Parent as a project, and specified that Child depends on Parent and that the build order should be Parent, then Child. The build succeeds, and as far I can tell, the right things show up in the Child/bin/debug directory: Parent.exe and Child.dll. However, if I run Parent.exe, then at the point when it should load a class from the Child.dll, it fails with the error message: exception executing operation System.TypeLoadException: Could not load type 'Child.some.class' from assembly 'Parent, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null'. I guess I'm confused as to how to get the Parent and Child projects to play together. I plan on having more child projects that use the same framework that is set up in the Parent, and so I do not want to move the entrypoint class down into the Child project. If I try to specify that the Child project is also a Console application, then the build process fails because there is no Main() entrypoint class in the child (even though the Parent project is included as a reference). Any help would be welcome! Thanks, Martin

    Read the article

  • Can't get NUnit to work in Visual Web Develper 2010 express.

    - by UkraineTrain
    First off I was wondering whether it's possible to implement a functionality with Nunit where each time a project is created in Visual Web Developer 2010 I get a dialog asking whether I want to create a unit test project for current application like I saw it happen in the older versions of Visual Web Developer. I've tried just about everything to get NUnit 2.5.5 to work in Visual Web Developer 2010. For example, in nunit.exe.config I added under configuration <startup> <requiredRuntime version="v4.0.30319" /> </startup> and under runtime: <loadFromRemoteSources enabled="true" /> I then tried to launch nunit-console.exe in order to specify in the command line the option /framework=net-4.0, but the console would appear and instantly disappear. It didn't help when I tried running it as an administrator. I've also tried using Nunit as an external tool inside the Visual Web Developer by creating a toolbar as described in the following link: http://www.marthijnvandenheuvel.com/2010/06/09/using-nunit-in-visual-studio-2010/. It shows up as an icon in the toolbar. I ran my project called ToyStore and then clicked Nunit icon in order to launch it and it gave me a "System.IO.FileNotFoundException:Assembly not found:ToyStore.dll". So, needless to say, I'm pretty lost and don't know what to do and would greatly appreciate any help in getting Nunit to work.

    Read the article

  • How to debug browser crash when running Silverlight app

    - by onedozenbagels
    I am on a team of three people who are developing a Silverlight application. On two of our developers' machines the app seems to randomly crash. It never crashes on the third developer's machine. The nature of the crash is that internet explorer just dies with an "Internet Explorer has stopped working" message. The problem details look like this: Problem Event Name: BEX Application Name: IEXPLORE.EXE Application Version: 8.0.6001.18882 Application Timestamp: 4b3ed243 Fault Module Name: StackHash_2cd8 Fault Module Version: 0.0.0.0 Fault Module Timestamp: 00000000 Exception Offset: 0024df00 Exception Code: c0000005 Exception Data: 00000008 OS Version: 6.0.6002.2.2.0.256.6 Locale ID: 1033 Additional Information 1: 2cd8 Additional Information 2: 0c337fa6c2057a9dbce1860c5e2d8315 Additional Information 3: e13b Additional Information 4: 5da012709e52526a1af19795dc4a33fd Then windows displays this message: "To help protect your computer, Data Execution Prevention has closed Internet Explorer." If I am attached to the app with the Visual Studio debugger the only information I get is this line in the output window: "The program '[2140] iexplore.exe: Silverlight' has exited with code -1073741819 (0xc0000005)." How should I go about debugging this problem? I'm not really sure where to start.

    Read the article

  • Check if files in a directory are still being written in Windows Batch File

    - by FMFF
    Hello. Here's my batch file to parse a directory, and zip files of certain type REM Begin ------------------------ tasklist /FI "IMAGENAME eq 7za.exe" /FO CSV > search.log FOR /F %%A IN (search.log) DO IF %%~zA EQU 0 GOTO end for /f "delims=" %%A in ('dir C:\Temp\*.ps /b') do ( "C:\Program Files\7-Zip\cmdline\7za.exe" a -tzip -mx9 "C:\temp\Zip\%%A.zip" "C:\temp\%%A" Move "C:\temp\%%A" "C:\Temp\Archive" ) :end del search.log REM pause exit REM End --------------------------- This code works just fine for 90% of my needs. It will be deployed as a scheduled task. However, the *.ps files are rather large (minimum of 1GB) in real time cases. So the code is supposed to check if the incoming file is completely written and is not locked by the application that is writing it. I saw another example elsewhere, that suggested the following approach :TestFile ren c:\file.txt c:\file.txt if errorlevel 0 goto docopy sleep 5 goto TestFile :docopy However this example is good for a fixed file. How can I use that many labels and GoTo's inside a for loop without causing an infinite loop? Or is this code safe to be used in the For Loop? Thank you for any help.

    Read the article

  • program "is not up to date" execution error in wedit lcc-win32

    - by Rowhawn
    I'm attempting to compile a simple hello world program in c with lcc-win32/wedit, and i'm a little unfamiliar with windows c programming. #include int main(void){ printf("hellow\n"); return 0; } When I compile the program the console output is Wedit output window build: Tue Jun 15 09:13:17 2010 c:\lcc\lib\lcccrt0.obj .text: undefined reference to '_RtlUnwind@16' c:\lcc\lib\lcccrt0.obj .text: undefined reference to '_signal' c:\lcc\lib\lcccrt0.obj .text: undefined reference to '_raise' c:\lcc\lib\lcccrt0.obj .text: undefined reference to '_exit' asctoq.obj .text: undefined reference to '_strnicmp' defaulttrap.obj .text: undefined reference to 'imp_iob' defaulttrap.obj .text: undefined reference to '_fwrite' defaulttrap.obj .text: undefined reference to '_itoa' defaulttrap.obj .text: undefined reference to '_strcat' defaulttrap.obj .text: undefined reference to '_MessageBoxA@16' defaulttrap.obj .text: undefined reference to '_abort' powlasm.obj .text: undefined reference to '_pow' qfloat.obj .text: undefined reference to '_memset' qfloat.obj .text: undefined reference to '_strchr' qfloat.obj .text: undefined reference to '_memmove' strlcpy.obj .text: undefined reference to '_memcpy' xprintf.obj .text: undefined reference to '_localeconv' xprintf.obj .text: undefined reference to '_strtol' xprintf.obj .text: undefined reference to '_wcslen' xprintf.obj .text: undefined reference to '_wctomb' xprintf.obj .text: undefined reference to '_fputc' search Compilation + link time:0.1 sec, Return code: 60 when I attempt to execute the program within wedit i get a dialog box that says "hello.exe is not up-to-date. Rebuild?" If I click yes, nothing happens. If I click no, a dos window pops up saying "C:\lcc\projects\lcc2\hello.exe" Return code -1 Execution time 0.001 seconds Press any key to continue... This continues to happen no matter how many times i compile/rebuild. Any ideas?

    Read the article

  • x86 CMP Instruction Difference

    - by Pindatjuh
    Question What is the (non-trivial) difference between the following two x86 instructions? 39 /r CMP r/m32,r32 Compare r32 with r/m32 3B /r CMP r32,r/m32 Compare r/m32 with r32 Background I'm building a Java assembler, which will be used by my compiler's intermediate language to produce Windows-32 executables. Currently I have following code: final ModelBase mb = new ModelBase(); // create new memory model mb.addCode(new Compare(Register.ECX, Register.EAX)); // add code mb.addCode(new Compare(Register.EAX, Register.ECX)); // add code final FileOutputStream fos = new FileOutputStream(new File("test.exe")); mb.writeToFile(fos); fos.close(); To output a valid executable file, which contains two CMP instruction in a TEXT-section. The executable outputted to "text.exe" will do nothing interesting, but that's not the point. The class Compare is a wrapper around the CMP instruction. The above code produces (inspecting with OllyDbg): Address Hex dump Command 0040101F |. 3BC8 CMP ECX,EAX 00401021 |. 3BC1 CMP EAX,ECX The difference is subtle: if I use the 39 byte-opcode: Address Hex dump Command 0040101F |. 39C1 CMP ECX,EAX 00401021 |. 39C8 CMP EAX,ECX Which makes me wonder about their synonymity and why this even exists.

    Read the article

  • Problem with apostrophes and other special characters when using aspell in windows

    - by Loftx
    Hi there, We seem to be having a problem with the spell checker on our content management system where it marks the ve part of We’ve as a misspelling. The spellchecker uses aspell which is called from a script on the server which executes the cmd.exe and uses it to pipe a file into aspell (it's a long winded way I know, but our server side programming langauge (ColdFusion) doesn't support writing to stdin for executables). Aspell is called by executing: c:\windows\system32\cmd.exe /c type d:\path_to_file\file.txt | "C:\Program Files\Aspell\bin\aspell" --lang=en -a Where file.txt contains the text to be spelled e.g. ^Oh have We’ve (the carat is added to prevent piping problems I believe). Aspell then output: @(#) International Ispell Version 3.1.20 (but really Aspell 0.50.3) * * * & ve 62 12: vie, voe, V, v, veg, vet, Be, Ce, be, Ev, E, e, vex, VA, VI, Va, Vi, vi, we, VD, VF, VG, VJ, VP, VT, Vt, vb, vs, DE, De, Fe, GE, Ge, He, IE, Le, ME, Me, NE, Ne, OE, PE, Re, SE, Se, Te, Xe, he, me, re, ye, Ave, Eve, Ive, ave, eve, VAR, var, veer, vier, view, vow However, we have a dev site, with the same version of Aspell, and when the same file is used it outputs with no misspellings. Both servers are running Aspell 0.50.3 on Windows server 2003, but there could be other differences in configuration: @(#) International Ispell Version 3.1.20 (but really Aspell 0.50.3) I'm wondering if the problem is to do with the piping part of the process or something different in the Aspell configuration. Does anyone have any ideas? Cheers, Tom