Search Results

Search found 13191 results on 528 pages for 'unhandled exception'.

Page 110/528 | < Previous Page | 106 107 108 109 110 111 112 113 114 115 116 117  | Next Page >

  • Application Does Not Start in Windows 7

    - by Jim Fell
    I recently installed a new 60GB SSD as my primary hard drive and re-installed Windows 7 Professional 64-bit. I then installed SSD Fresh from Abelssoft to optimize Windows to run on the SSD. It seemed to install okay, but when I try to run the utility, its splash screen appears briefly before it quietly closes. No errors are displayed; the utility just fails to launch. I have run SSD Fresh on another SSD-equipped Windows 7 Pro x64 computer in the past without any problems. Does anyone know what might be preventing the program from running? I tried running sfc /scannow from the command line (with administrator privileges), shutting down the Spybot Resident, and disabling the firewall and virus scanner. I also tried running the tool as administrator; I even tried reinstalling it, running the installer as administrator. No luck. Every time I try to launch the program the Event Viewer logs this same set of errors: Error 4/2/2012 11:35:44 PM Application Error 1000 (100) Faulting application name: SSDFresh.exe, version: 1.0.0.0, time stamp: 0x4f2a45d8 Faulting module name: unknown, version: 0.0.0.0, time stamp: 0x00000000 Exception code: 0xc0000005 Fault offset: 0x000007ff0016dbba Faulting process id: 0x994 Faulting application start time: 0x01cd11fd9fe978df Faulting application path: C:\Program Files (x86)\SSD Fresh\SSDFresh.exe Faulting module path: unknown Report Id: dfeed551-7df0-11e1-a2c7-002522c47ec0 Error 4/2/2012 11:35:43 PM .NET Runtime 1026 None Application: SSDFresh.exe Framework Version: v4.0.30319 Description: The process was terminated due to an unhandled exception. Exception Info: System.NullReferenceException Stack: at AbBugReporter.BugForm.InitLanguage() at AbBugReporter.BugForm..ctor(AbFlexTrans.LanguageInfo, AbBugReporter.BugReportManager, Boolean) at AbBugReporter.BugReportManager.Show(System.Exception) at SSDFresh.App.App_DispatcherUnhandledException(System.Object, System.Windows.Threading.DispatcherUnhandledExceptionEventArgs) at System.Windows.Threading.Dispatcher.CatchException(System.Exception) at MS.Internal.Threading.ExceptionFilterHelper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate) at System.Windows.Threading.Dispatcher.WrappedInvoke(System.Delegate, System.Object, Int32, System.Delegate) at System.Windows.Threading.Dispatcher.InvokeImpl(System.Windows.Threading.DispatcherPriority, System.TimeSpan, System.Delegate, System.Object, Int32) at MS.Win32.HwndSubclass.SubclassWndProc(IntPtr, Int32, IntPtr, IntPtr) at MS.Win32.UnsafeNativeMethods.DispatchMessage(System.Windows.Interop.MSG ByRef) at System.Windows.Threading.Dispatcher.PushFrameImpl(System.Windows.Threading.DispatcherFrame) at System.Windows.Application.RunInternal(System.Windows.Window) at System.Windows.Application.Run() at SSDFresh.App.Main() Error 4/2/2012 11:35:39 PM SideBySide 59 None Activation context generation failed for "C:\Windows\Microsoft.NET\Framework64\v4.0.30319\csc.exe".Error in manifest or policy file "C:\Windows\Microsoft.NET\Framework64\v4.0.30319\csc.exe.Config" on line 0. Invalid Xml syntax. Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None Error 4/2/2012 11:35:39 PM SideBySide 59 None For those who are interested, here is my system configuration: ASRock M3A770DE AM3 AMD 770 ATX AMD Motherboard AMD Athlon II X3 455 Rana 3.3GHz Socket AM3 95W Triple-Core Desktop Processor ADX455WFGMBOX G.SKILL Value Series 8GB (2 x 4GB) 240-Pin DDR3 SDRAM DDR3 1333 (PC3 10600) Desktop Memory Model F3-10600CL9D-8GBNT Mushkin Enhanced Chronos Deluxe MKNSSDCR60GB-DX 2.5" 60GB SATA III Synchronous MLC Internal Solid State Drive (SSD) (Primary/Boot HD) Western Digital Caviar Blue RFHWD1600AAJS 160GB 7200 RPM SATA 3.0Gb/s 3.5" Internal Hard Drive -Bare Drive (Secondary HD) Sony Optiarc CD/DVD Burner Black SATA Model AD-7261S-0B LightScribe Support RAIDMAX RX-850AE 850W ATX12V v2.3 / EPS12V SLI Certified CrossFire Ready 80 PLUS GOLD Certified Modular Active PFC Power Supply ASUS HD7850-DC2-2GD5 Radeon HD 7850 2GB 256-bit GDDR5 PCI Express 3.0 x16 HDCP Ready CrossFireX Support Video Card Asus ML228H 21.5" Full HD LED BackLight LED Monitor Slim Design (x3)

    Read the article

  • Fake ISAPI Handler to serve static files with extention that are rewritted by url rewriter

    - by developerit
    Introduction I often map html extention to the asp.net dll in order to use url rewritter with .html extentions. Recently, in the new version of www.nouvelair.ca, we renamed all urls to end with .html. This works great, but failed when we used FCK Editor. Static html files would not get serve because we mapped the html extension to the .NET Framework. We can we do to to use .html extension with our rewritter but still want to use IIS behavior with static html files. Analysis I thought that this could be resolve with a simple HTTP handler. We would map urls of static files in our rewriter to this handler that would read the static file and serve it, just as IIS would do. Implementation This is how I coded the class. Note that this may not be bullet proof. I only tested it once and I am sure that the logic behind IIS is more complicated that this. If you find errors or think of possible improvements, let me know. Imports System.Web Imports System.Web.Services ' Author: Nicolas Brassard ' For: Solutions Nitriques inc. http://www.nitriques.com ' Date Created: April 18, 2009 ' Last Modified: April 18, 2009 ' License: CPOL (http://www.codeproject.com/info/cpol10.aspx) ' Files: ISAPIDotNetHandler.ashx ' ISAPIDotNetHandler.ashx.vb ' Class: ISAPIDotNetHandler ' Description: Fake ISAPI handler to serve static files. ' Usefull when you want to serve static file that has a rewrited extention. ' Example: It often map html extention to the asp.net dll in order to use url rewritter with .html. ' If you want to still serve static html file, add a rewritter rule to redirect html files to this handler Public Class ISAPIDotNetHandler Implements System.Web.IHttpHandler Sub ProcessRequest(ByVal context As HttpContext) Implements IHttpHandler.ProcessRequest ' Since we are doing the job IIS normally does with html files, ' we set the content type to match html. ' You may want to customize this with your own logic, if you want to serve ' txt or xml or any other text file context.Response.ContentType = "text/html" ' We begin a try here. Any error that occurs will result in a 404 Page Not Found error. ' We replicate the behavior of IIS when it doesn't find the correspoding file. Try ' Declare a local variable containing the value of the query string Dim uri As String = context.Request("fileUri") ' If the value in the query string is null, ' throw an error to generate a 404 If String.IsNullOrEmpty(uri) Then Throw New ApplicationException("No fileUri") End If ' If the value in the query string doesn't end with .html, then block the acces ' This is a HUGE security hole since it could permit full read access to .aspx, .config, etc. If Not uri.ToLower.EndsWith(".html") Then ' throw an error to generate a 404 Throw New ApplicationException("Extention not allowed") End If ' Map the file on the server. ' If the file doesn't exists on the server, it will throw an exception and generate a 404. Dim fullPath As String = context.Server.MapPath(uri) ' Read the actual file Dim stream As IO.StreamReader = FileIO.FileSystem.OpenTextFileReader(fullPath) ' Write the file into the response context.Response.Output.Write(stream.ReadToEnd) ' Close and Dipose the stream stream.Close() stream.Dispose() stream = Nothing Catch ex As Exception ' Set the Status Code of the response context.Response.StatusCode = 404 'Page not found ' For testing and bebugging only ! This may cause a security leak ' context.Response.Output.Write(ex.Message) Finally ' In all cases, flush and end the response context.Response.Flush() context.Response.End() End Try End Sub ' Automaticly generated by Visual Studio ReadOnly Property IsReusable() As Boolean Implements IHttpHandler.IsReusable Get Return False End Get End Property End Class Conclusion As you see, with our static files map to this handler using query string (ex.: /ISAPIDotNetHandler.ashx?fileUri=index.html) you will have the same behavior as if you ask for the uri /index.html. Finally, test this only in IIS with the html extension map to aspnet_isapi.dll. Url rewritting will work in Casini (Internal Web Server shipped with Visual Studio) but it’s not the same as with IIS since EVERY request is handle by .NET. Versions First release

    Read the article

  • What are developer's problems with helpful error messages?

    - by Moo-Juice
    It continue to astounds me that, in this day and age, products that have years of use under their belt, built by teams of professionals, still to this day - fail to provide helpful error messages to the user. In some cases, the addition of just a little piece of extra information could save a user hours of trouble. A program that generates an error, generated it for a reason. It has everything at its disposal to inform the user as much as it can, why something failed. And yet it seems that providing information to aid the user is a low-priority. I think this is a huge failing. One example is from SQL Server. When you try and restore a database that is in use, it quite rightly won't let you. SQL Server knows what processes and applications are accessing it. Why can't it include information about the process(es) that are using the database? I know not everyone passes an Applicatio_Name attribute on their connection string, but even a hint about the machine in question could be helpful. Another candidate, also SQL Server (and mySQL) is the lovely string or binary data would be truncated error message and equivalents. A lot of the time, a simple perusal of the SQL statement that was generated and the table shows which column is the culprit. This isn't always the case, and if the database engine picked up on the error, why can't it save us that time and just tells us which damned column it was? On this example, you could argue that there may be a performance hit to checking it and that this would impede the writer. Fine, I'll buy that. How about, once the database engine knows there is an error, it does a quick comparison after-the-fact, between values that were going to be stored, versus the column lengths. Then display that to the user. ASP.NET's horrid Table Adapters are also guilty. Queries can be executed and one can be given an error message saying that a constraint somewhere is being violated. Thanks for that. Time to compare my data model against the database, because the developers are too lazy to provide even a row number, or example data. (For the record, I'd never use this data-access method by choice, it's just a project I have inherited!). Whenever I throw an exception from my C# or C++ code, I provide everything I have at hand to the user. The decision has been made to throw it, so the more information I can give, the better. Why did my function throw an exception? What was passed in, and what was expected? It takes me just a little longer to put something meaningful in the body of an exception message. Hell, it does nothing but help me whilst I develop, because I know my code throws things that are meaningful. One could argue that complicated exception messages should not be displayed to the user. Whilst I disagree with that, it is an argument that can easily be appeased by having a different level of verbosity depending on your build. Even then, the users of ASP.NET and SQL Server are not your typical users, and would prefer something full of verbosity and yummy information because they can track down their problems faster. Why to developers think it is okay, in this day and age, to provide the bare minimum amount of information when an error occurs? It's 2011 guys, come on.

    Read the article

  • ASP.NET MVC HandleError Attribute

    - by Ben Griswold
    Last Wednesday, I took a whopping 15 minutes out of my day and added ELMAH (Error Logging Modules and Handlers) to my ASP.NET MVC application.  If you haven’t heard the news (I hadn’t until recently), ELMAH does a killer job of logging and reporting nearly all unhandled exceptions.  As for handled exceptions, I’ve been using NLog but since I was already playing with the ELMAH bits I thought I’d see if I couldn’t replace it. Atif Aziz provided a quick solution in his answer to a Stack Overflow question.  I’ll let you consult his answer to see how one can subclass the HandleErrorAttribute and override the OnException method in order to get the bits working.  I pretty much took rolled the recommended logic into my application and it worked like a charm.  Along the way, I did uncover a few HandleError fact to which I wasn’t already privy.  Most of my learning came from Steven Sanderson’s book, Pro ASP.NET MVC Framework.  I’ve flipped through a bunch of the book and spent time on specific sections.  It’s a really good read if you’re looking to pick up an ASP.NET MVC reference. Anyway, my notes are found a comments in the following code snippet.  I hope my notes clarify a few things for you too. public class LogAndHandleErrorAttribute : HandleErrorAttribute {     public override void OnException(ExceptionContext context)     {         // A word from our sponsors:         //      http://stackoverflow.com/questions/766610/how-to-get-elmah-to-work-with-asp-net-mvc-handleerror-attribute         //      and Pro ASP.NET MVC Framework by Steven Sanderson         //         // Invoke the base implementation first. This should mark context.ExceptionHandled = true         // which stops ASP.NET from producing a "yellow screen of death." This also sets the         // Http StatusCode to 500 (internal server error.)         //         // Assuming Custom Errors aren't off, the base implementation will trigger the application         // to ultimately render the "Error" view from one of the following locations:         //         //      1. ~/Views/Controller/Error.aspx         //      2. ~/Views/Controller/Error.ascx         //      3. ~/Views/Shared/Error.aspx         //      4. ~/Views/Shared/Error.ascx         //         // "Error" is the default view, however, a specific view may be provided as an Attribute property.         // A notable point is the Custom Errors defaultRedirect is not considered in the redirection plan.         base.OnException(context);           var e = context.Exception;                  // If the exception is unhandled, simply return and let Elmah handle the unhandled exception.         // Otherwise, try to use error signaling which involves the fully configured pipeline like logging,         // mailing, filtering and what have you). Failing that, see if the error should be filtered.         // If not, the error simply logged the exception.         if (!context.ExceptionHandled                || RaiseErrorSignal(e)                   || IsFiltered(context))                  return;           LogException(e); // FYI. Simple Elmah logging doesn't handle mail notifications.     }

    Read the article

  • MongoDB usage best practices

    - by andresv
    The project I'm working on uses MongoDB for some stuff so I'm creating some documents to help developers speedup the learning curve and also avoid mistakes and help them write clean & reliable code. This is my first version of it, so I'm pretty sure I will be adding more stuff to it, so stay tuned! C# Official driver notes The 10gen official MongoDB driver should always be referenced in projects by using NUGET. Do not manually download and reference assemblies in any project. C# driver quickstart guide: http://www.mongodb.org/display/DOCS/CSharp+Driver+Quickstart Reference links C# Language Center: http://www.mongodb.org/display/DOCS/CSharp+Language+Center MongoDB Server Documentation: http://www.mongodb.org/display/DOCS/Home MongoDB Server Downloads: http://www.mongodb.org/downloads MongoDB client drivers download: http://www.mongodb.org/display/DOCS/Drivers MongoDB Community content: http://www.mongodb.org/display/DOCS/CSharp+Community+Projects Tutorials Tutorial MongoDB con ASP.NET MVC - Ejemplo Práctico (Spanish):http://geeks.ms/blogs/gperez/archive/2011/12/02/tutorial-mongodb-con-asp-net-mvc-ejemplo-pr-225-ctico.aspx MongoDB and C#:http://www.codeproject.com/Articles/87757/MongoDB-and-C C# driver LINQ tutorial:http://www.mongodb.org/display/DOCS/CSharp+Driver+LINQ+Tutorial C# driver reference: http://www.mongodb.org/display/DOCS/CSharp+Driver+Tutorial Safe Mode Connection The C# driver supports two connection modes: safe and unsafe. Safe connection mode (only applies to methods that modify data in a database like Inserts, Deletes and Updates. While the current driver defaults to unsafe mode (safeMode == false) it's recommended to always enable safe mode, and force unsafe mode on specific things we know aren't critical. When safe mode is enabled, the driver internal code calls the MongoDB "getLastError" function to ensure the last operation is completed before returning control the the caller. For more information on using safe mode and their implicancies on performance and data reliability see: http://www.mongodb.org/display/DOCS/getLastError+Command If safe mode is not enabled, all data modification calls to the database are executed asynchronously (fire & forget) without waiting for the result of the operation. This mode could be useful for creating / updating non-critical data like performance counters, usage logging and so on. It's important to know that not using safe mode implies that data loss can occur without any notification to the caller. As with any wait operation, enabling safe mode also implies dealing with timeouts. For more information about C# driver safe mode configuration see: http://www.mongodb.org/display/DOCS/CSharp+getLastError+and+SafeMode The safe mode configuration can be specified at different levels: Connection string: mongodb://hostname/?safe=true Database: when obtaining a database instance using the server.GetDatabase(name, safeMode) method Collection: when obtaining a collection instance using the database.GetCollection(name, safeMode) method Operation: for example, when executing the collection.Insert(document, safeMode) method Some useful SafeMode article: http://stackoverflow.com/questions/4604868/mongodb-c-sharp-safemode-official-driver Exception Handling The driver ensures that an exception will be thrown in case of something going wrong, in case of using safe mode (as said above, when not using safe mode no exception will be thrown no matter what the outcome of the operation is). As explained here https://groups.google.com/forum/?fromgroups#!topic/mongodb-user/mS6jIq5FUiM there is no need to check for any returned value from a driver method inserting data. With updates the situation is similar to any other relational database: if an update command doesn't affect any records, the call will suceed anyway (no exception thrown) and you manually have to check for something like "records affected". For MongoDB, an Update operation will return an instance of the "SafeModeResult" class, and you can verify the "DocumentsAffected" property to ensure the intended document was indeed updated. Note: Please remember that an Update method might return a null instance instead of an "SafeModeResult" instance when safe mode is not enabled. Useful Community Articles Comments about how MongoDB works and how that might affect your application: http://ethangunderson.com/blog/two-reasons-to-not-use-mongodb/ FourSquare using MongoDB had serious scalability problems: http://mashable.com/2010/10/07/mongodb-foursquare/ Is MongoDB a replacement for Memcached? http://www.quora.com/Is-MongoDB-a-good-replacement-for-Memcached/answer/Rick-Branson MongoDB Introduction, shell, when not to use, maintenance, upgrade, backups, memory, sharding, etc: http://www.markus-gattol.name/ws/mongodb.html MongoDB Collection level locking support: https://jira.mongodb.org/browse/SERVER-1240 MongoDB performance tips: http://www.quora.com/MongoDB/What-are-some-best-practices-for-optimal-performance-of-MongoDB-particularly-for-queries-that-involve-multiple-documents Lessons learned migrating from SQL Server to MongoDB: http://www.wireclub.com/development/TqnkQwQ8CxUYTVT90/read MongoDB replication performance: http://benshepheard.blogspot.com.ar/2011/01/mongodb-replication-performance.html

    Read the article

  • Anatomy of a serialization killer

    - by Brian Donahue
    As I had mentioned last month, I have been working on a project to create an easy-to-use managed debugger. It's still an internal tool that we use at Red Gate as part of product support to analyze application errors on customer's computers, and as such, should be easy to use and not require installation. Since the project has got rather large and important, I had decided to use SmartAssembly to protect all of my hard work. This was trivial for the most part, but the loading and saving of results was broken by SA after using the obfuscation, rendering the loading and saving of XML results basically useless, although the merging and error reporting was an absolute godsend and definitely worth the price of admission. (Well, I get my Red Gate licenses for free, but you know what I mean!)My initial reaction was to simply exclude the serializable results class and all of its' members from obfuscation, and that was just dandy, but a few weeks on I decided to look into exactly why serialization had broken and change the code to work with SA so I could write any new code to be compatible with SmartAssembly and save me some additional testing and changes to the SA project.In simple terms, SA does all that it can to prevent serialization problems, for instance, it will not obfuscate public members of a DLL and it will exclude any types with the Serializable attribute from obfuscation. This prevents public members and properties from being made private and having the name changed. If the serialization is done inside the executable, however, public members have the access changed to private and are renamed. That was my first problem, because my types were in the executable assembly and implemented ISerializable, but did not have the Serializable attribute set on them!public class RedFlagResults : ISerializable        {        }The second problem caused by the pruning feature. Although RedFlagResults had public members, they were not truly properties, and used the GetObjectData() method of ISerializable to serialize the members. For that reason, SA could not exclude these members from pruning and further broke the serialization. public class RedFlagResults : ISerializable        {                public List<RedFlag.Exception> Exceptions;                 #region ISerializable Members                 public void GetObjectData(SerializationInfo info, StreamingContext context)                {                                info.AddValue("Exceptions", Exceptions);                }                 #endregionSo to fix this, it was necessary to make Exceptions a proper property by implementing get and set on it. Also, I added the Serializable attribute so that I don't have to exclude the class from obfuscation in the SA project any more. The DoNotPrune attribute means I do not need to exclude the class from pruning.[Serializable, SmartAssembly.Attributes.DoNotPrune]        public class RedFlagResults        {                public List<RedFlag.Exception> Exceptions {get;set;}        }Similarly, the Exception class gets the Serializable and DoNotPrune attributes applied so all of its' properties are excluded from obfuscation.Now my project has some protection from prying eyes by scrambling up the code so it's harder to reverse-engineer, without breaking anything. SmartAssembly has also provided the benefit of merging so that the end-user doesn't need to extract all of the DLL files needed by RedFlag into a directory, and can be run directly from the .zip archive. When an error occurs (hey, I'm only human!), an exception report can be sent to me so I can see what went wrong without having to, er, debug the debugger.

    Read the article

  • Doubts about several best practices for rest api + service layer

    - by TheBeefMightBeTough
    I'm going to be starting a project soon that exposes a restful api for business intelligence. It may not be limited to a restful api, so I plan to delegate requests to a service layer that then coordinates multiple domain objects (each of which have business logic local to the object). The api will likely have many calls as it is a long-term project. While thinking about the design, I recalled a few best practices. 1) Use command objects at the controller layer (I'm using Spring MVC). 2) Use DTOs at the service layer. 3) Validate in both the controller and service layer, though for different reasons. I have my doubts about these recommendations. 1) Using command objects adds a lot of extra single-purpose classes (potentially one per request). What exactly is the benefit? Annotation based validation can be done using this approach, sure. What if I have two requests that take the same parameters, but have different validation requirements? I would have to have two different classes with exactly the same members but different annotations? Bleh. 2) I have heard that using DTOs is preferable to parameters because it makes for more maintainable code down the road (say, e.g., requirements change and the service parameters need to be altered). I don't quite understand this. Shouldn't an api be more-or-less set in stone? I would understand that in the early phases of a project (or, especially, an entire company) the domain itself will not be well understood, and thus core domain objects may change along with the apis that manipulate these objects. At this point however the number of api methods should be small and their dependents few, so changes to the methods could easily be tolerated from a maintainability standpoint. In a large api with many methods and a substantial domain model, I would think having a DTO for potentially each domain object would become unwieldy. Am I misunderstanding something here? 3) I see validation in the controller and service layer as redundant in most cases. Why would I validate that parameters are not null and are in general well formed in the controller if the service is going to do exactly the same (and more). Couldn't I just do all the validation in the service and throw a runtime exception with a list of bad parameters then catch that in the controller to make the error messages more presentable? Better yet, couldn't I just make the error messages user-friendly in the service and let the exception trickle up to a global handler (ControllerAdvice in spring, for example)? Is there something wrong with either of these approaches? (I do see a use case for controller validation if the input does not map one-to-one with the service input, but since the controllers are for a rest api and not forms, the api parameters will probably map directly to service parameters.) I do also have a question about unchecked vs checked exceptions. Namely, I'm not really sure why I'd ever want to use a checked exception. Every time I have seen them used they just get wrapped into general exceptions (DomainException, SystemException, ApplicationException, w/e) to reduce the signature length of methods, or devs catch Exception rather than dealing with the App1Exception, App2Exception, Sys1Exception, Sys2Exception. I don't see how either of these practices is very useful. Why not just use unchecked exceptions always and catch the ones you actually do care about? You could just document what unchecked exceptions the method throws.

    Read the article

  • How to layout class definition when inheriting from multiple interfaces

    - by gabr
    Given two interface definitions ... IOmniWorkItem = interface ['{3CE2762F-B7A3-4490-BF22-2109C042EAD1}'] function GetData: TOmniValue; function GetResult: TOmniValue; function GetUniqueID: int64; procedure SetResult(const value: TOmniValue); // procedure Cancel; function DetachException: Exception; function FatalException: Exception; function IsCanceled: boolean; function IsExceptional: boolean; property Data: TOmniValue read GetData; property Result: TOmniValue read GetResult write SetResult; property UniqueID: int64 read GetUniqueID; end; IOmniWorkItemEx = interface ['{3B48D012-CF1C-4B47-A4A0-3072A9067A3E}'] function GetOnWorkItemDone: TOmniWorkItemDoneDelegate; function GetOnWorkItemDone_Asy: TOmniWorkItemDoneDelegate; procedure SetOnWorkItemDone(const Value: TOmniWorkItemDoneDelegate); procedure SetOnWorkItemDone_Asy(const Value: TOmniWorkItemDoneDelegate); // property OnWorkItemDone: TOmniWorkItemDoneDelegate read GetOnWorkItemDone write SetOnWorkItemDone; property OnWorkItemDone_Asy: TOmniWorkItemDoneDelegate read GetOnWorkItemDone_Asy write SetOnWorkItemDone_Asy; end; ... what are your ideas of laying out class declaration that inherits from both of them? My current idea (but I don't know if I'm happy with it): TOmniWorkItem = class(TInterfacedObject, IOmniWorkItem, IOmniWorkItemEx) strict private FData : TOmniValue; FOnWorkItemDone : TOmniWorkItemDoneDelegate; FOnWorkItemDone_Asy: TOmniWorkItemDoneDelegate; FResult : TOmniValue; FUniqueID : int64; strict protected procedure FreeException; protected //IOmniWorkItem function GetData: TOmniValue; function GetResult: TOmniValue; function GetUniqueID: int64; procedure SetResult(const value: TOmniValue); protected //IOmniWorkItemEx function GetOnWorkItemDone: TOmniWorkItemDoneDelegate; function GetOnWorkItemDone_Asy: TOmniWorkItemDoneDelegate; procedure SetOnWorkItemDone(const Value: TOmniWorkItemDoneDelegate); procedure SetOnWorkItemDone_Asy(const Value: TOmniWorkItemDoneDelegate); public constructor Create(const data: TOmniValue; uniqueID: int64); destructor Destroy; override; public //IOmniWorkItem procedure Cancel; function DetachException: Exception; function FatalException: Exception; function IsCanceled: boolean; function IsExceptional: boolean; property Data: TOmniValue read GetData; property Result: TOmniValue read GetResult write SetResult; property UniqueID: int64 read GetUniqueID; public //IOmniWorkItemEx property OnWorkItemDone: TOmniWorkItemDoneDelegate read GetOnWorkItemDone write SetOnWorkItemDone; property OnWorkItemDone_Asy: TOmniWorkItemDoneDelegate read GetOnWorkItemDone_Asy write SetOnWorkItemDone_Asy; end; As noted in answers, composition is a good approach for this example but I'm not sure it applies in all cases. Sometimes I'm using multiple inheritance just to split read and write access to some property into public (typically read-only) and private (typically write-only) part. Does composition still apply here? I'm not really sure as I would have to move the property in question out from the main class and I'm not sure that's the correct way to do it. Example: // public part of the interface interface IOmniWorkItemConfig = interface function OnExecute(const aTask: TOmniBackgroundWorkerDelegate): IOmniWorkItemConfig; function OnRequestDone(const aTask: TOmniWorkItemDoneDelegate): IOmniWorkItemConfig; function OnRequestDone_Asy(const aTask: TOmniWorkItemDoneDelegate): IOmniWorkItemConfig; end; // private part of the interface IOmniWorkItemConfigEx = interface ['{42CEC5CB-404F-4868-AE81-6A13AD7E3C6B}'] function GetOnExecute: TOmniBackgroundWorkerDelegate; function GetOnRequestDone: TOmniWorkItemDoneDelegate; function GetOnRequestDone_Asy: TOmniWorkItemDoneDelegate; end; // implementing class TOmniWorkItemConfig = class(TInterfacedObject, IOmniWorkItemConfig, IOmniWorkItemConfigEx) strict private FOnExecute : TOmniBackgroundWorkerDelegate; FOnRequestDone : TOmniWorkItemDoneDelegate; FOnRequestDone_Asy: TOmniWorkItemDoneDelegate; public constructor Create(defaults: IOmniWorkItemConfig = nil); public //IOmniWorkItemConfig function OnExecute(const aTask: TOmniBackgroundWorkerDelegate): IOmniWorkItemConfig; function OnRequestDone(const aTask: TOmniWorkItemDoneDelegate): IOmniWorkItemConfig; function OnRequestDone_Asy(const aTask: TOmniWorkItemDoneDelegate): IOmniWorkItemConfig; public //IOmniWorkItemConfigEx function GetOnExecute: TOmniBackgroundWorkerDelegate; function GetOnRequestDone: TOmniWorkItemDoneDelegate; function GetOnRequestDone_Asy: TOmniWorkItemDoneDelegate; end;

    Read the article

  • ASP.NET MVC tries to load older version of Owin assembly

    - by d_mcg
    As a bit of context, I'm developing an ASP.NET MVC 5 application that uses OAuth-based authentication via Microsoft's OWIN implementation, for Facebook and Google only at this stage. Currently (as of v3.0.0, git-commit 4932c2f), the FacebookAuthenticationOptions and GoogleOAuth2AuthenticationOptions don't provide any property to force Facebook nor Google respectively to reauthenticate users (via appending the appropriate query string parameters) when signing in. Initially, I set out to override the following classes: FacebookAuthenticationOptions GoogleOAuth2AuthenticationOptions FacebookAuthenticationHandler (specifically AuthenticateCoreAsync()) GoogleOAuth2AuthenticationHandler (specifically AuthenticateCoreAsync()) yet discovered that the ~AuthenticationHandler classes are marked as internal. So I pulled a copy of the source for the Katana project (http://katanaproject.codeplex.com/) and modified the source accordingly. After compiling, I found that there are several dependencies that needed updating in order to use these updated assemblies (Microsoft.Owin.Security.Facebook and Microsoft.Owin.Security.Google) in the MVC project: Microsoft.Owin Microsoft.Owin.Security Microsoft.Owin.Security.Cookies Microsoft.Owin.Security.OAuth Microsoft.Owin.Host.SystemWeb This was done by replacing the existing project references to the 3.0.0 versions and updating those in web.config. Good news: the project compiles successfully. In debugging, I received an exception on startup: An exception of type 'System.IO.FileLoadException' occurred in [MVC web assembly].dll but was not handled in user code Additional information: Could not load file or assembly 'Microsoft.Owin.Security, Version=3.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The located assembly's manifest definition does not match the assembly reference. (Exception from HRESULT: 0x80131040) The underlying exception indicated that Microsoft.AspNet.Identity.Owin was trying to load v2.1.0 of Microsoft.Owin.Security when calling app.UseExternalSignInCookie() from Startup.ConfigureAuth(IAppBuilder app) in Startup.Auth.cs. Unfortunately that assembly (and its other dependency, Microsoft.AspNet.Identity.Owin) aren't part of the Project Katana solution, and I can't find any accessible repository for these assemblies online. Are the Microsoft.AspNet.Identity assemblies open source, like the Katana project? Is there a way to fool those assemblies to use the referenced v3.0.0 assemblies instead of v2.1.0? The /bin folder contains the 3.0.0 versions of the Owin assemblies. I've upgraded the NuGet packages for Microsoft.AspNet.Identity.Owin, and this is still an issue. Any ideas on how to resolve this issue?

    Read the article

  • VS 2012 / 2013 AccessViolationException

    - by Goran
    When I run the project (F5) I receive the following exception in IDE: An unhandled exception of type 'System.AccessViolationException' occurred in System.Windows.Forms.dll Additional information: Attempted to read or write protected memory. This is often an indication that other memory is corrupt. Stack trace reports at System.Windows.Forms.UnsafeNativeMethods.SendMessage(HandleRef hWnd, Int32 msg, IntPtr wParam, IntPtr lParam) at System.Windows.Forms.Control.SendMessage(Int32 msg, Int32 wparam, IntPtr lparam) at System.Windows.Forms.Form.UpdateWindowIcon(Boolean redrawFrame) at System.Windows.Forms.Form.CreateHandle() at System.Windows.Forms.Control.get_Handle() at Microsoft.VisualStudio.HostingProcess.HostProc.RunParkingWindowThread() at System.Threading.ExecutionContext.RunInternal(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart() I have never noticed receiving the same exception when running without debugger (CTRL+F5). This is a WPF project, but exception occurs before the App_ctor is executed, so this is external code, and my application code did not start to execute. This happens sporadically, sometimes it happens only once, and sometimes I run the project and get this message for several times in a roll. Then it does not pop up for 5-6 runs, and then starts again. Anyone knows why is this happening? I have just installed clean W8.1 64 bit, VS2013 and TFS 2013 (although I had the same problem with W8 and VS2012, but not as often).

    Read the article

  • Commit in sharpSVN

    - by Pedro
    Hello! I have a problem doing commit with sharpsvn. Now i´m adding all the files of my working copy (if the file is added throws an exception), and after it i do commit. It works but it trows exceptions. There is some way to get the status of the repository before do add() and only add the new files or the files who are changed? And if i delete one file or folder on my working copy , How can i delete these files or folder on the repository? Code: String[] folders; folders = Directory.GetDirectories(direccionLocal,"*.*", SearchOption.AllDirectories); foreach (String folder in folders) { String[] files; files = Directory.GetFiles(folder); foreach (String file in files) { if (file.IndexOf("\\.svn") == -1) { Add(file, workingcopy); } } } Commit(workingcopy, "change"); Add: public bool Add(string path, string direccionlocal) { using (SvnClient client = new SvnClient()) { SvnAddArgs args = new SvnAddArgs(); args.Depth = SvnDepth.Empty; Console.Out.WriteLine(path); args.AddParents = true; try { return client.Add(path, args); } catch (Exception ex) { return false; } } } Commit: public bool Commit(string path, string message) { using (SvnClient client = new SvnClient()) { SvnCommitArgs args = new SvnCommitArgs(); args.LogMessage = message; args.ThrowOnError = true; args.ThrowOnCancel = true; try { return client.Commit(path, args); } catch (Exception e) { if (e.InnerException != null) { throw new Exception(e.InnerException.Message, e); } throw e; } } }

    Read the article

  • Entity Framework with MySQL - Timeout Expired while Generating Model

    - by Nathan Taylor
    I've constructed a database in MySQL and I am attempting to map it out with Entity Framework, but I start running into "GenerateSSDLException"s whenever I try to add more than about 20 tables to the EF context. An exception of type 'Microsoft.Data.Entity.Design.VisualStudio.ModelWizard.Engine.ModelBuilderEngine+GenerateSSDLException' occurred while attempting to update from the database. The exception message is: 'An error occurred while executing the command definition. See the inner exception for details.' Fatal error encountered during command execution. Timeout expired. The timeout period elapsed prior to completion of the operation or the server is not responding. There's nothing special about the affected tables, and it's never the same table(s), it's just that after a certain (unspecific) number of tables have been added, the context can no longer be updated without the "Timeout expired" error. Sometimes it's only one table left over, and sometimes it's three; results are pretty unpredictable. Furthermore, the variance in the number of tables which can be added before the error indicates to me that perhaps the problem lies in the size of the query being generated to update the context which includes both the existing table definitions, and also the new tables that are being added to it. Essentially, the SQL query is getting too large and it's failing to execute for some reason. If I generate the model with EdmGen2 it works without any errors, but the generated EDMX file cannot be updated within Visual Studio without producing the aforementioned exception. In all likelihood the source of this problem lies in the tool within Visual Studio given that EdmGen2 works fine, but I'm hoping that perhaps others could offer some advice on how to approach this very unique issue, because it seems like I'm not the only person experiencing it. One suggestion a colleague offered was maintaining two separate EBMX files with some table crossover, but that seems like a pretty ugly fix in my opinion. I suppose this is what I get for trying to use "new technology". :(

    Read the article

  • Loading GeckoWebBrowser Exceptions

    - by Mostafa Mahdieh
    I get a strange exception when a window containing a GeckoWebBrowser is loaded. This is the exception message: An unhandled exception of type System.Runtime.InteropServices.COMException occurred in Skybound.Gecko.dll Additional information: Class not registered (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)) This is the windows code: public partial class AddContents : Form { String path; public AddContents(String path) { this.path = path; InitializeComponent(); } private void exitToolStripMenuItem_Click(object sender, EventArgs e) { this.Close(); } private void AddContents_Load(object sender, EventArgs e) { geckoWebBrowser1.Navigate(path); } private int selId = 1; private bool updateMode = false; private void timer1_Tick(object sender, EventArgs e) { if (updateMode) update(); } private void geckoWebBrowser1_DocumentCompleted(object sender, EventArgs e) { timer1.Enabled = true; updateMode = true; } private void treeView1_AfterSelect(object sender, TreeViewEventArgs e) { geckoWebBrowser1.Navigate("javascript:scrollToBookmark(" + treeView1.SelectedNode.Tag + ")"); TreeNode selected = treeView1.SelectedNode; TreeNode prev = selected.PrevNode; TreeNode next = selected.PrevNode; if (prev == null) upButton.Enabled = false; if (next == null) downButton.Enabled = false; } private void update() { geckoWebBrowser1.Navigate("javascript:updateSelText()"); GeckoElement el = geckoWebBrowser1.Document.GetElementById("sel_result_991231"); if (el != null) { textBox1.Text = el.InnerHtml; addButton.Enabled = !textBox1.Text.Trim().Equals(String.Empty); } } private void textBox1_Enter(object sender, EventArgs e) { updateMode = false; } private void geckoWebBrowser1_DomMouseDown(object sender, GeckoDomMouseEventArgs e) { updateMode = true; update(); } private void geckoWebBrowser1_DomMouseUp(object sender, GeckoDomMouseEventArgs e) { updateMode = false; } private void addButton_Click(object sender, EventArgs e) { geckoWebBrowser1.Navigate("javascript:addIdToSel()"); TreeNode t = new TreeNode(textBox1.Text); t.Tag = selId; treeView1.Nodes.Add(t); selId++; } }

    Read the article

  • Handling async ASMX web service exceptions

    - by Andy
    Hi, I've developed silverlight client with makes async web services calls to a asmx web service. The problem is, I want to handle exceptions, so far as to be able to tell in the client application whether there was an exception in the webservice (and therefore will be logged local to the webservice) or whether there was a communication problem (i.e. the endpoint for the webservice was wrong). In testing both types of exceptions in my project I get the same generic exception: System.ServiceModel.CommunicationException: The remote server returned an error: NotFound. This exception is amazingly useless when an exception occured in the webservice as it clearly has been found. Is the presence of this generic error to do with security (not being allowed to see true errors)? It can't be the fact that I don't have debug strings as I'm running on a dev PC. Either way, my question is, what's the best way to handle async errors in a commercial silverlight application? Any links or ideas are most welcome! :) Thanks a lot! Andy.

    Read the article

  • FileNotFoundException when running WiX CustomAction with COMAdmin interop

    - by dabcabc
    I am trying to create a WiX custom action which will allow me to shutdown and clear down a COM+ package as part of an upgrade installation, or create and configure a new COM+ package as part of the initial installation. I previously had this running as a CustomAction within a standard Visual Studio MSI but this only allows the custom action to be executed after the files have been copied - which will fail as the package will still be running. The COMAdmin.dll has been added as a reference to the CustomAction project and is set CopyLocal=true. In the bin folder for the custom action project the Interop.COMAdmin.dll is present. The answer to this question seems to suggest that it should work. I am getting the following exception within the MSI log when trying to install: MSI (s) (C4:04) [10:40:34:205]: Invoking remote custom action. DLL: C:\WINDOWS\Installer\MSI119.tmp, Entrypoint: BeforeInstall SFXCA: Extracting custom action to temporary directory: C:\WINDOWS\Installer\MSI119.tmp-\ SFXCA: Binding to CLR version v2.0.50727 Calling custom action MyCustomAction!MyCustomAction.CustomActions.BeforeInstall Exception thrown by custom action: System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation. ---> System.IO.FileNotFoundException: Could not load file or assembly 'Interop.COMAdmin, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null' or one of its dependencies. The system cannot find the file specified. File name: 'Interop.COMAdmin, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null' at MyCustomAction.CustomActions.BeforeInstall(Session session) WRN: Assembly binding logging is turned OFF. To enable assembly bind failure logging, set the registry value (DWORD) to 1. Note: There is some performance penalty associated with assembly bind failure logging. To turn this feature off, remove the registry value . --- End of inner exception stack trace --- at System.RuntimeMethodHandle._InvokeMethodFast(Object target, Object arguments, SignatureStruct& sig, MethodAttributes methodAttributes, RuntimeTypeHandle typeOwner) at System.RuntimeMethodHandle.InvokeMethodFast(Object target, Object arguments, Signature sig, MethodAttributes methodAttributes, RuntimeTypeHandle typeOwner) at System.Reflection.RuntimeMethodInfo.Invoke(Object obj, BindingFlags invokeAttr, Binder binder, Object parameters, CultureInfo culture, Boolean skipVisibilityChecks) at System.Reflection.RuntimeMethodInfo.Invoke(Object obj, BindingFlags invokeAttr, Binder binder, Object parameters, CultureInfo culture) at Microsoft.Deployment.WindowsInstaller.CustomActionProxy.InvokeCustomAction(Int32 sessionHandle, String entryPoint, IntPtr remotingDelegatePtr)

    Read the article

  • What does suds mean by "<faultcode/> not mapped to message part" ?

    - by Pratik Patel
    I'm using suds for the first time and trying to communicate with a server hosted by an external company. When I call a method on the server I get this XML back. soap:Server Can't use string ("") as an ARRAY ref while "strict refs" in use at /vindicia/site_perl/Vindicia/Soap/DocLitUtils.pm line 130. The exception thrown is this: File "C:\Python26\lib\site-packages\suds-0.4-py2.6.egg\suds\client.py", line 538, in __call__ return client.invoke(args, kwargs) File "C:\Python26\lib\site-packages\suds-0.4-py2.6.egg\suds\client.py", line 602, in invoke result = self.send(msg) File "C:\Python26\lib\site-packages\suds-0.4-py2.6.egg\suds\client.py", line 634, in send result = self.succeeded(binding, reply.message) File "C:\Python26\lib\site-packages\suds-0.4-py2.6.egg\suds\client.py", line 669, in succeeded r, p = binding.get_reply(self.method, reply) File "C:\Python26\lib\site-packages\suds-0.4-py2.6.egg\suds\bindings\binding.py", line 157, in get_reply result = self.replycomposite(rtypes, nodes) File "C:\Python26\lib\site-packages\suds-0.4-py2.6.egg\suds\bindings\binding.py", line 227, in replycomposite raise Exception(' not mapped to message part' % tag) Exception: not mapped to message part Any idea why suds is throwing the exception? Any thoughts on how it could be fixed?

    Read the article

  • Grails Mail port configuration

    - by bsreekanth
    Hello, I am trying to send mail through grails mail plugin. I configured according to the documentation, and also followed few blog posts (http://blog.lourish.com/2010/04/02/sending-asynchronous-html-email-in-grails-with-activemq-jms-and-gmail/). That post mention that the closure way of declaring the configuration overrides others, but not true. Anyway I tried both approach, but seems like the port is still use the smtp default one. I get the below exception. exception: org.springframework.mail.MailSendException: Mail server connection failed; nested exception is javax.mail.MessagingException: Could not connect to SMTP host: localhost, port: 25; nested exception is: java.net.ConnectException: Connection refused: connect Now, I wrote a small program directly using the java mail library, and I could send the mail with that. The configuration is shown below. tried additional config "mail.smtp.port":"465"", but no change.. used the parameters mentioned in the above blog post, result same grails { mail { host = "smtp.gmail.com" port = "465" username = "[email protected]" password = "mypwd" props = ["mail.smtp.auth":"true", // "mail.smtp.port":"465", "mail.smtp.socketFactory.port":"465", "mail.smtp.socketFactory.class":"javax.net.ssl.SSLSocketFactory", "mail.smtp.socketFactory.fallback":"false"] } } thanks in advance.. Update: It is not port or firewall config, as when I made a grails application from scratch, and tried with the same config, everything works. Also, asked in grails forum http://grails.1312388.n4.nabble.com/grails-mail-mailSender-does-not-have-config-values-td2237704.html#a2237704 . Hope get a lead to try.

    Read the article

  • Weird RecordStore behavior when RecordStoreFullException occurs

    - by Michael P
    Hello everyone! I'm developing a small J2ME application that displays bus stops timetables - they are stored as records in MIDP RecordStores. Sometimes records can not fit a single RecordStore, especially on record update - using setRecord method - a RecordStoreFullException occurs. I catch the exception, and try to write the record to a new RecordStore along with deleting the previous one in the old RecordStore. Everything works fine except of deleting record from RecordStore where the RecordStoreFullException occurs. If I make an attempt to delete record that could not be updated, another Exception of type InvalidRecordIDException is thrown. This is weird and undocumented in MIDP javadoc. I have tested it on Sun WTK 2.5.2, MicroEdition SDK 3.0 and Nokia Series 40 SDK. Furthermore I created a code that reproduces this strange behaviour: RecordStore rms = null; int id = 0; try { rms = RecordStore.openRecordStore("Test", true); byte[] raw = new byte[192*10024]; //Big enough to cause RecordStoreFullException id = rms.addRecord(raw, 0, 160); rms.setRecord(id, raw, 0, raw.length); } catch (Exception e) { try { int count = rms.getNumRecords(); RecordEnumeration en = rms.enumerateRecords(null, null, true); count = en.numRecords(); while(en.hasNextElement()){ System.out.println("NextID: "+en.nextRecordId()); } rms.deleteRecord(id); //this won't work! rms.setRecord(id, new byte[5], 0, 5); //this won't work too! } catch (Exception ex) { ex.printStackTrace(); } } I added extra enumeration code to produce other weird behavior - when RecordStoreFullException occurs, count variable will be set to 1 (if RMS was empty) by both methods - getNumRecords and numRecords. System.out.println will produce NextID: 0! It is not acceptable because record ID can not be 0! Could someone explain this strange behavior? Sorry for my bad English.

    Read the article

  • local variable 'sresult' referenced before assignment

    - by user288558
    I have had multiple problems trying to use PP. I am running python2.6 and pp 1.6.0 rc3. Using the following test code: import pp nodes=('mosura02','mosura03','mosura04','mosura05','mosura06', 'mosura09','mosura10','mosura11','mosura12') def pptester(): js=pp.Server(ppservers=nodes) tmp=[] for i in range(200): tmp.append(js.submit(ppworktest,(),(),('os',))) return tmp def ppworktest(): return os.system("uname -a") gives me the following result: In [10]: Exception in thread run_local: Traceback (most recent call last): File "/usr/lib64/python2.6/threading.py", line 525, in __bootstrap_inner self.run() File "/usr/lib64/python2.6/threading.py", line 477, in run self.__target(*self.__args, **self.__kwargs) File "/home/wkerzend/python_coala/lib/python2.6/site-packages/pp.py", line 751, in _run_local job.finalize(sresult) UnboundLocalError: local variable 'sresult' referenced before assignment Exception in thread run_local: Traceback (most recent call last): File "/usr/lib64/python2.6/threading.py", line 525, in __bootstrap_inner self.run() File "/usr/lib64/python2.6/threading.py", line 477, in run self.__target(*self.__args, **self.__kwargs) File "/home/wkerzend/python_coala/lib/python2.6/site-packages/pp.py", line 751, in _run_local job.finalize(sresult) UnboundLocalError: local variable 'sresult' referenced before assignment Exception in thread run_local: Traceback (most recent call last): File "/usr/lib64/python2.6/threading.py", line 525, in __bootstrap_inner self.run() File "/usr/lib64/python2.6/threading.py", line 477, in run self.__target(*self.__args, **self.__kwargs) File "/home/wkerzend/python_coala/lib/python2.6/site-packages/pp.py", line 751, in _run_local job.finalize(sresult) UnboundLocalError: local variable 'sresult' referenced before assignment Exception in thread run_local: Traceback (most recent call last): File "/usr/lib64/python2.6/threading.py", line 525, in __bootstrap_inner self.run() File "/usr/lib64/python2.6/threading.py", line 477, in run self.__target(*self.__args, **self.__kwargs) File "/home/wkerzend/python_coala/lib/python2.6/site-packages/pp.py", line 751, in _run_local job.finalize(sresult) UnboundLocalError: local variable 'sresult' referenced before assignment any help greatly appreciated

    Read the article

  • Error when creating a new entity foo, editing a previously existing foo, then saving. Generic 4004 e

    - by Tarks
    The steps are as simple as that so I imagine there's something else going on here, the problem is I just get back 4004, no exception anywhere etc, making it annoying to debug, I get this from the ie error window Microsoft JScript runtime error: Unhandled Error in Silverlight Application Code: 4004 Category: ManagedRuntimeError Message: System.Windows.Ria.DomainOperationException: Submit operation failed. An error occurred while updating the entries. See the inner exception for details. at System.Windows.Ria.OperationBase.Complete(Exception error) at System.Windows.Ria.SubmitOperation.Complete(Exception error) at System.Windows.Ria.DomainContext.CompleteSubmitChanges(IAsyncResult asyncResult) at System.Windows.Ria.DomainContext.<c_DisplayClassd.b_5(Object ) public void TurnPage(bool forward) { TurnPageForward = forward; // If the pages are already turning then don't try and skip days, just run the animation function so it inreases the speed if (!workBook.IsTransitioning && !IsWaitingForData) { IsWaitingForData = true; workBook.SnapshotPages(); NoteCtx.SubmitChanges().Completed += (s, a) => { workBook.ClearPageContents(); CurrentDate = CurrentDate.AddDays(forward ? 1 : -1); PullNotes(CurrentDate); }; } else { workBook.BeginTurnPages(TurnPageForward); } } public void PullNotes(DateTime? noteTime) { NoteCtx.NoteItems.Clear(); var loadOp = NoteCtx.Load(NoteCtx.GetNoteItemsForDayQuery(CurrentDate)); loadOp.Completed += new EventHandler(NotesReady); }

    Read the article

  • android throw InvocationTargetException,How to modify the error

    - by fonter
    ActivityManager am = (ActivityManager)this.getSystemService(this.ACTIVITY_SERVICE); try { clearMethod = am.getClass() .getMethod("clearApplicationUserData", String.class, IPackageDataObserver.class); } catch (Exception e) { Log.e("Error", "Android Error",e); clearMethod = null; } if(clearMethod!=null){ try { clearMethod.invoke(am,"com.android.browser",new ClearUserDataObserver()); } catch (Exception e) { Log.e("Error", "Android Exception",e); } } Exception 05-26 08:34:13.056: ERROR/Error(739): java.lang.reflect.InvocationTargetException 05-26 08:34:13.056: ERROR/Error(739): at android.app.ActivityManager.clearApplicationUserData(ActivityManager.java:475) 05-26 08:34:13.056: ERROR/Error(739): at java.lang.reflect.Method.invokeNative(Native Method) 05-26 08:34:13.056: ERROR/Error(739): at java.lang.reflect.Method.invoke(Method.java:521) 05-26 08:34:13.056: ERROR/Error(739): at com.iwidsets.clear.manager.AndClear.onCreate(AndClear.java:34) 05-26 08:34:13.056: ERROR/Error(739): at android.app.Instrumentation.callActivityOnCreate(Instrumentation.java:1123) 05-26 08:34:13.056: ERROR/Error(739): at android.app.ActivityThread.performLaunchActivity(ActivityThread.java:2364) 05-26 08:34:13.056: ERROR/Error(739): at android.app.ActivityThread.handleLaunchActivity(ActivityThread.java:2417) 05-26 08:34:13.056: ERROR/Error(739): at android.app.ActivityThread.access$2100(ActivityThread.java:116) 05-26 08:34:13.056: ERROR/Error(739): at android.app.ActivityThread$H.handleMessage(ActivityThread.java:1794) 05-26 08:34:13.056: ERROR/Error(739): at android.os.Handler.dispatchMessage(Handler.java:99) 05-26 08:34:13.056: ERROR/Error(739): at android.os.Looper.loop(Looper.java:123) 05-26 08:34:13.056: ERROR/Error(739): at android.app.ActivityThread.main(ActivityThread.java:4203) 05-26 08:34:13.056: ERROR/Error(739): at java.lang.reflect.Method.invokeNative(Native Method) 05-26 08:34:13.056: ERROR/Error(739): at java.lang.reflect.Method.invoke(Method.java:521) 05-26 08:34:13.056: ERROR/Error(739): at com.android.internal.os.ZygoteInit$MethodAndArgsCaller.run(ZygoteInit.java:791) 05-26 08:34:13.056: ERROR/Error(739): at com.android.internal.os.ZygoteInit.main(ZygoteInit.java:549) 05-26 08:34:13.056: ERROR/Error(739): at dalvik.system.NativeStart.main(Native Method) 05-26 08:34:13.056: ERROR/Error(739): Caused by: java.lang.SecurityException: 739 does not have permission:android.permission.CLEAR_APP_USER_DATA to clear datafor process:com.android.browser 05-26 08:34:13.056: ERROR/Error(739): at android.os.Parcel.readException(Parcel.java:1218) 05-26 08:34:13.056: ERROR/Error(739): at android.os.Parcel.readException(Parcel.java:1206) 05-26 08:34:13.056: ERROR/Error(739): at android.app.ActivityManagerProxy.clearApplicationUserData(ActivityManagerNative.java:2016) 05-26 08:34:13.056: ERROR/Error(739): ... 17 more

    Read the article

  • Hibernate: "Field 'id' doesn't have a default value"

    - by André Neves
    Hi, all. I'm facing what I think is a simple problem with Hibernate, but can't get over it (Hibernate forums being unreachable certainly doesn't help). I have a simple class I'd like to persist, but keep getting: SEVERE: Field 'id' doesn't have a default value Exception in thread "main" org.hibernate.exception.GenericJDBCException: could not insert: [hibtest.model.Mensagem] at org.hibernate.exception.SQLStateConverter.handledNonSpecificException(SQLStateConverter.java:103) at org.hibernate.exception.SQLStateConverter.convert(SQLStateConverter.java:91) [ a bunch more ] Caused by: java.sql.SQLException: Field 'id' doesn't have a default value [ a bunch more ] The relevant code for the persisted class is: package hibtest.model; import javax.persistence.Entity; import javax.persistence.GeneratedValue; import javax.persistence.Id; import javax.persistence.Inheritance; import javax.persistence.InheritanceType; @Entity @Inheritance(strategy = InheritanceType.JOINED) public class Mensagem { protected Long id; protected Mensagem() { } @Id @GeneratedValue public Long getId() { return id; } public Mensagem setId(Long id) { this.id = id; return this; } } And the actual running code is just plain: SessionFactory factory = new AnnotationConfiguration() .configure() .buildSessionFactory(); { Session session = factory.openSession(); Transaction tx = session.beginTransaction(); Mensagem msg = new Mensagem("YARR!"); session.save(msg); tx.commit(); session.close(); } I tried some "strategies" within the GeneratedValue annotation but it just doesn't seem to work. Initializing id doesn't help either! (eg Long id = 20L). Could anyone shed some light? EDIT 2: confirmed: messing with@GeneratedValue(strategy = GenerationType.XXX) doesn't solve it SOLVED: recreating the database solved the problem

    Read the article

  • not able to Deserialize xml into object

    - by Ravisha
    I am having following peice of code ,where in i am trying to serialize and deserailize object of StringResource class. Please note Resource1.stringXml = its coming from resource file.If i pass strelemet.outerXMl i get the object from Deserialize object ,but if i pass Resource1.stringXml i am getting following exception {"< STRING xmlns='' was not expected."} System.Exception {System.InvalidOperationException} class Program { static void Main(string[] args) { StringResource str = new StringResource(); str.DELETE = "CanDelete"; str.ID= "23342"; XmlElement strelemet = SerializeObjectToXmlNode (str); StringResource strResourceObject = DeSerializeXmlNodeToObject<StringResource>(Resource1.stringXml); Console.ReadLine(); } public static T DeSerializeXmlNodeToObject<T>(string objectNodeOuterXml) { try { TextReader objStringsTextReader = new StringReader(objectNodeOuterXml); XmlSerializer stringResourceSerializer = new XmlSerializer(typeof(T),string.Empty); return (T)stringResourceSerializer.Deserialize(objStringsTextReader); } catch (Exception excep) { return default(T); } } public static XmlElement SerializeObjectToXmlNode(object obj) { using (MemoryStream memoryStream = new MemoryStream()) { try { XmlSerializerNamespaces xmlNameSpace = new XmlSerializerNamespaces(); xmlNameSpace.Add(string.Empty, string.Empty); XmlWriterSettings writerSettings = new XmlWriterSettings(); writerSettings.CloseOutput = false; writerSettings.Encoding = System.Text.Encoding.UTF8; writerSettings.Indent = false; writerSettings.OmitXmlDeclaration = true; XmlWriter writer = XmlWriter.Create(memoryStream, writerSettings); XmlSerializer xmlserializer = new XmlSerializer(obj.GetType()); xmlserializer.Serialize(writer, obj, xmlNameSpace); writer.Close(); memoryStream.Position = 0; XmlDocument serializeObjectDoc = new XmlDocument(); serializeObjectDoc.Load(memoryStream); return serializeObjectDoc.DocumentElement; } catch (Exception excep) { return null; } } } } public class StringResource { [XmlAttribute] public string DELETE; [XmlAttribute] public string ID; } < STRING ID="1" DELETE="True" /

    Read the article

  • How can I inject an object into an WCF IErrorHandler implementation with Castle Windsor?

    - by Michael Johnson
    I'm developing a set of services using WCF. The application is doing dependency injection with Castle Windsor. I've added an IErrorHandler implementation that is added to services via an attribute. Everything is working thus far. The IErrorHandler object (of a class called FaultHandler is being applied properly and invoked. Now I'm adding logging. Castle Windsor is set up to inject the logger object (an instance of IOurLogger). This is working. But when I try to add it to FaultHandler my logger is null. The code for FaultHandler looks something like this: class FaultHandler : IErrorHandler { public IOurLogger logger { get; set; } public bool HandleError(Exception error) { logger.Write("Exception type {0}. Message: {1}", error.GetType(), error.Message); // Let WCF handle things its way. We only want to log. return false; } public void ProvideFault(Exception error, MessageVersion version, Message fault) { } } This throws it's own exception, since logger is null when HandleError() is called. The logger is being successfully injected into the service itself and is usable there, but for some reason I can't use it in FaultHandler. Update: Here is the relevant part of the Windsor configuration file (edited to protect the innocent): <configuration> <components> <component id="Logger" service="Our.Namespace.IOurLogger, Our.Namespace" type="Our.Namespace.OurLogger, Our.Namespace" /> </components> </configuration>

    Read the article

  • Execution permission cannot be acquired for Outlook 2003 addin

    - by khushnuma
    I am developing a simple Outlook 2003 add-in using VSTO 2008. Everything works fine on development environment. But when I try to install the addin it gives following load error. I think there is some security related issue. Please help me in resolving this issue. Could not load file or assembly 'OutlookAddIn, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null' or one of its dependencies. Failed to grant permission to execute. (Exception from HRESULT: 0x80131418) ************** Exception Text ************** System.IO.FileLoadException: Could not load file or assembly 'OutlookAddIn, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null' or one of its dependencies. Failed to grant permission to execute. (Exception from HRESULT: 0x80131418) File name: 'OutlookAddIn, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null' --- System.Security.Policy.PolicyException: Execution permission cannot be acquired. at System.Security.SecurityManager.ResolvePolicy(Evidence evidence, PermissionSet reqdPset, PermissionSet optPset, PermissionSet denyPset, PermissionSet& denied, Boolean checkExecutionPermission) at System.Security.SecurityManager.ResolvePolicy(Evidence evidence, PermissionSet reqdPset, PermissionSet optPset, PermissionSet denyPset, PermissionSet& denied, Int32& securitySpecialFlags, Boolean checkExecutionPermission) at Microsoft.VisualStudio.Tools.Applications.Runtime.AppDomainManagerInternal.HandleOnlineOffline(Exception e, String basePath, String filePath) at Microsoft.VisualStudio.Tools.Applications.Runtime.AppDomainManagerInternal.LoadStartupAssembly(EntryPoint entryPoint, Dependency dependency, Dictionary`2 assembliesHash) at Microsoft.VisualStudio.Tools.Applications.Runtime.AppDomainManagerInternal.ConfigureAppDomain() at Microsoft.VisualStudio.Tools.Applications.Runtime.AppDomainManagerInternal.LoadAssembliesAndConfigureAppDomain(IHostServiceProvider serviceProvider) at Microsoft.VisualStudio.Tools.Applications.Runtime.AppDomainManagerInternal.LoadEntryPointsHelper(IHostServiceProvider serviceProvider) ************** Loaded Assemblies ************** mscorlib Assembly Version: 2.0.0.0 Win32 Version: 2.0.50727.3603 (GDR.050727-3600) CodeBase: file:///C:/WINDOWS/Microsoft.NET/Framework/v2.0.50727/mscorlib.dll ---------------------------------------- Microsoft.VisualStudio.Tools.Applications.Runtime Assembly Version: 8.0.0.0 Win32 Version: 8.0.50727.940 CodeBase: file:///C:/WINDOWS/assembly/GAC_MSIL/Microsoft.VisualStudio.Tools.Applications.Runtime/8.0.0.0__b03f5f7f11d50a3a/Microsoft.VisualStudio.Tools.Applications.Runtime.dll ---------------------------------------- Microsoft.Office.Tools.Common Assembly Version: 8.0.0.0 Win32 Version: 8.0.50727.940 CodeBase: file:///C:/WINDOWS/assembly/GAC_MSIL/Microsoft.Office.Tools.Common/8.0.0.0__b03f5f7f11d50a3a/Microsoft.Office.Tools.Common.dll ---------------------------------------- System Assembly Version: 2.0.0.0 Win32 Version: 2.0.50727.3053 (netfxsp.050727-3000) CodeBase: file:///C:/WINDOWS/assembly/GAC_MSIL/System/2.0.0.0__b77a5c561934e089/System.dll ---------------------------------------- System.Windows.Forms Assembly Version: 2.0.0.0 Win32 Version: 2.0.50727.3053 (netfxsp.050727-3000) CodeBase: file:///C:/WINDOWS/assembly/GAC_MSIL/System.Windows.Forms/2.0.0.0__b77a5c561934e089/System.Windows.Forms.dll ----------------------------------------

    Read the article

< Previous Page | 106 107 108 109 110 111 112 113 114 115 116 117  | Next Page >