Search Results

Search found 43800 results on 1752 pages for 'drupal domain access'.

Page 111/1752 | < Previous Page | 107 108 109 110 111 112 113 114 115 116 117 118  | Next Page >

  • Drupal - how to add add same page to two menus?

    - by bert
    How can I add same callback to 2 different menus? function my_callback_menu(){ $items = array(); $items['my_callback'] = array( 'title' => t('My title'), 'menu_name' => 'menu-my-menu', 'page callback' => 'my_callback', 'access arguments' => array('access content'), ); return $items; }

    Read the article

  • Populating data in multiple cascading dropdown boxes in Access 2007

    - by miCRoSCoPiC_eaRthLinG
    Hello all, I've been assigned the task to design a temporary customer tracking system in MS Access 2007 (sheeeesh!). The tables and relationships have all been setup successfully. But I'm running into a minor problem while trying to design the data entry form for one table... Here's a bit of explanation first. The screen contains 3 dropdown boxes (apart from other fields). 1st dropdown The first dropdown (cboMarket) represents the Market lets users select between 2 options: Domestic International Since the first dropdown contains only 2 items I didn't bother making a table for it. I added them as pre-defined list items. 2nd dropdown Once the user makes a selection in this one, the second dropdown (cboLeadCategory) loads up a list of Lead Categories, namely, Fairs & Exhibitions, Agents, Press Ads, Online Ads etc. Different sets of lead categories are utilized for the 2 markets. Hence this box is dependent on the 1st one. Structure of the bound table, named Lead_Cateogries for the 2nd combo is: ID Autonumber Lead_Type TEXT <- actually a list that takes up Domestic or International Lead_Category_Name TEXT 3rd dropdown And based on the choice of category in the 2nd one, the third one (cboLeadSource) is supposed to display a pre-defined set of lead sources belonging to the particular category. Table is named Lead_Sources and the structure is: ID Autonumber Lead_Category NUMBER <- related to ID of Lead Categories table Lead_Source TEXT When I make the selection in the 1st dropdown, the AfterUpdate event of the combo is called, which instructs the 2nd dropdown to load contents: Private Sub cboMarket_AfterUpdate() Me![cboLead_Category].Requery End Sub The Row Source of the 2nd combo contains a query: SELECT Lead_Categories.ID, Lead_Categories.Lead_Category_Name FROM Lead_Categories WHERE Lead_Categories.Lead_Type=[cboMarket] ORDER BY Lead_Categories.Lead_Category_Name; The AfterUpdate event of 2nd combo is: Private Sub cboLeadCategory_AfterUpdate() Me![cboLeadSource].Requery End Sub The Row Source of 3rd combo contains: SELECT Leads_Sources.ID, Leads_Sources.Lead_Source FROM Leads_Sources WHERE [Lead_Sources].[Lead_Category]=[Lead_Categories].[ID] ORDER BY Leads_Sources.Lead_Source; Problem When I select Market type from cboMarket, the 2nd combo cboLeadCategory loads up the appropriate Categories without a hitch. But when I select a particular Category from it, instead of the 3rd combo loading the lead source names, a modal dialog is displayed asking me to Enter a Parameter. When I enter anything into this prompt (valid or invalid data), I get yet another prompt: Why is this happening? Why isn't the 3rd box loading the source names as desired. Can any one please shed some light on where I am going wrong? Thanks, m^e

    Read the article

  • How to output JSON from within Django and call it with jQuery from a cross domain?

    - by Emre Sevinç
    For a bookmarklet project I'm trying to get JSON data using jQuery from my server (which is naturally on a different domain) running a Django powered system. According to jQuery docs: "As of jQuery 1.2, you can load JSON data located on another domain if you specify a JSONP callback, which can be done like so: "myurl?callback=?". jQuery automatically replaces the ? with the correct method name to call, calling your specified callback." And for example I can test it successfully in my Firebug console using the following snippet: $.getJSON("http://api.flickr.com/services/feeds/photos_public.gne?tags=cat&tagmode=any& format=json&jsoncallback=?", function(data){ alert(data.title); }); It prints the returned data in an alert window, e.g. 'Recent uploads tagged cat'. However when I try the similar code with my server I don't get anything at all: $.getJSON("http://mydjango.yafz.org/randomTest?jsoncallback=?", function(data){ alert(data.title); }); There are no alert windows and the Firebug status bar says "Transferring data from mydjango.yafz.org..." and keeps on waiting. On the server side I have this: def randomTest(request): somelist = ['title', 'This is a constant result'] encoded = json.dumps(somelist) response = HttpResponse(encoded, mimetype = "application/json") return response I also tried this without any success: def randomTest(request): if request.is_ajax() == True: req = {} req ['title'] = 'This is a constant result.' response = json.dumps(req) return HttpResponse(response, mimetype = "application/json") So to cut a long story short: what is the suggested method of returning a piece of data from within a Django view and retrieve it using jQuery in a cross domain fashion? What are my mistakes above?

    Read the article

  • INSERT INTO in MS Access 2010 SOMETIMES GETS ERROR: 3073 Operation must use an updateable query

    - by Gary
    I get the ERROR: 3073 Operation must use an updateable query SOMETIMES, while performing an INSERT statment. I have no problem on my windows 7 PC, but the person I am writing this for sometimes gets the error. She also has MS Access 2010 on Windows 7. As I said I have never got it on my PC, and she only gets it sometimes. The code will insert a number of rows and then through the error, and other times not through the erro at all. The error occurs if I have the code and data in one .mdb file or seperate files. Here a snippet of code: OrderHdrInsertStmnt = " INSERT INTO ORDER_HDR " _ & "(ORDER_ID, SOURCE_CODE, ORDER_DATE, SHIP_FNAME, SHIP_LNAME, SHIP_EMAIL, SHIP_COMP, SHIP_PHONE, SHIP_ADDR, SHIP_CITY, SHIP_STATE, SHIP_ZIP, SHIP_CNTRY, " _ & " BILL_FNAME, BILL_LNAME, BILL_EMAIL, BILL_COMP, BILL_PHONE, BILL_ADDR, BILL_CITY, BILL_STATE, BILL_ZIP, BILL_CNTRY, " _ & " TAX, SHIPPING, TOTAL, MOD_DATE, INSERT_DATE) " _ & " VALUES (" _ & "'" & OrderId & "','" & SourceCode & "','" & Orderdate & "','" & ShipFName & "','" & ShipLName & "','" & ShipEmail & "','" & ShipComp & "','" & ShipPhone & "','" & ShipAddr & "','" & ShipCity & "','" & ShipState & "','" & ShipZip & "','" & ShipCntry _ & "','" & BillFName & "','" & BillLName & "','" & BillEmail & "','" & BillComp & "','" & BillPhone & "','" & BillAddr & "','" & BillCity & "','" & BillState & "','" & BillZip & "','" & BillCntry _ & "','" & OrderTax & "','" & OrderShipping & "','" & OrderTotal & "','" & ImportDate & "','" & ImportDate & "');" then I use dbsCurrent.Execute OrderHdrInsertStmnt, dbFailOnError Any assistance would be great!

    Read the article

  • Drupal menu with submenus only shows submenu of current page. NOT a CSS problem

    - by jordanstephens
    This is not a CSS problem. The HTML isn't there. I need the menu, with submenus to exist in HTML on EACH page. Right now, the submenu only exists in HTML for the submenu related to the page being currently viewed. Here's an example of what it SHOULD be like. <ul id="menu"> <li>Page1 <ul class="sub"> <li>sub1.1</li> <li>sub1.2</li> <li>sub1.3</li> <li>sub1.4</li> </ul> </li> <li>Page2 <ul class="sub"> <li>sub2.1</li> <li>sub2.2</li> <li>sub2.3</li> <li>sub2.4</li> </ul> </li> <li>Page3 <ul class="sub"> <li>sub3.1</li> <li>sub3.2</li> <li>sub3.3</li> <li>sub3.4</li> </ul> </li> </ul> But here is what is actually happening (say I'm currently viewing Page2): <ul id="menu"> <li>Page1</li> <li>Page2 <ul class="sub"> <li>sub2.1</li> <li>sub2.2</li> <li>sub2.3</li> <li>sub2.4</li> </ul> </li> <li>Page3</li> </ul> Additionally, and maybe this doesn't have anything to do with it, but whichever list item <li> element is relative to the page i am currently on is given these classes expanded active-trail and any other <li> is given collapsed class. The classes aren't really so much of an issue, the problem is just that the content (html) isn't there. Does anyone have any idea what's going on here. I feel like I've been digging in the Drupal Admin menus forever now. I feel like it's got to have a PHP solution in the template file or something, but I don't know Drupal super well at this point. Thank you!

    Read the article

  • Can I use the character ñ in a sub-domain?

    - by nute
    We are launching our website in Spanish and are probably going to call it espanol.mydomain.com Since the real spelling is español, ideally we would allow people to type español.mydomain.com. Is that something that is possible today? Can we use this character in domains and sub-domains?

    Read the article

  • Wireless access point -> Powerline -> Router -> Internet, should this work?

    - by Anthony
    My network at home used to be a laptop and desktop connected wirelessly to a single Wireless ADSL router, a Cisco 877W. Wireless reception around the house with this setup was quite unreliable, so I've gone about looking to improve it. I purchased some Belkin Gigabit powerline adapters and I've got these working fine. I can hook a computer up to one of the powerline adapters, and with the other one plugged into the ADSL router the computer has internet access. Additionally I can hook a Netgear DG834G Wireless ADSL router into it with the adsl not plugged in, and after turning off DHCP can RJ45 a computer up to the network. Everything works fine. However, if I setup a wireless network on the Netgear then any computer that connects wirelessly to it cannot access the internet. It gets an IP address very slowly via DHCP which is a good one, but it cannot access the internet. It can however communicate with the RJ45'd computer also connected to the Netgear. I wondered whether this could be a problem with the Netgear so I've borrowed a Cisco Aironet 1200 and got this working fine when it's attached directly to the primary ADSL router. I can connect to it wireless and get onto the internet. However, if I then plug it into the Netgear I can communicate with other devices attached to the Netgear, but can't get any further than the Netgear. All the while though the other devices RJ45'd to the Netgear are communicating with the internet just fine. I'm starting to suspect it's one of two things causing the problem: 1) For some reason the belkin powerline adapters don't like carrying wireless-originating signals. Could this be possible? 2) The primary Cisco ADSL router doesn't want to communicate with other devices on my network more than one hop away from it. I'm making an assumption here that within the Netgear box the wireless and wired sides are handled differently. Could this be true? Has anyone successfully setup something similar to what I'm trying, with a wireless device on the otherside of a pair of powerline connectors? Update 06/07/2010 - Response to irrational John 28 June Thanks for the answer John - and for clearing up some of my questions. The model number of the belkin powerline adapters are F5D4076. Security was apparently enabled by default on them, and I didn't change them from their default setting. The network diagram in your answer shows exactly what I'm trying to setup: I've followed that guide and I'm still not able to get things working properly. The thing that perplexes me is that wired network traffic works just fine - it's only the wireless traffic that doesn't. This is with the same laptop, and the same DHCP or static IPs. "1. What IP addresses did you assign to each router? What subnet masks are you using?" - subnet is 255.255.255.0, the router connected to the adsl is 192.168.153.1 and that has the DHCP server. The access point on the other side of the powerline adapters I've tried both a static IP of 192.168.153.110, same subnet, and a DHCP-assigned IP. The other devices are DHCP, although I also tried manually entering IP settings. "2. Have you correctly enabled DHCP on only one of the routers and disabled it on all the others?" Yes I have - only the internet-connected router has DHCP enabled. The IP range for the DHCP is from 192.168.153.11 - 192.168.153.200. The strange thing is that wired connections work fine on the LAN, plugged into any router, work fine - it's only the wireless connections that aren't working when they're plugged into the non-primary AP. "Since the routers you are using appear to integrate an ADSL modem I'm assuming there is no WAN port on them." There's no NAT within the LAN, and all wired connections are connected to LAN ports. It's something wrong with the wireless - wired works fine throughout the whole LAN. Update 06/07/2010 - Response to irrational John 29 June The diagram you've drawn in your answer shows pretty much exactly what I'm trying to do. I've spent another evening trying different things and made some progress but I'm still scratching my head. I've borrowed a Netgear access point and been trying with this, and the strange thing is that my PC is working now - this is a Windows 7 PC connected to the access point in the position of where the DG834G is in the diagram. Meanwhile, however, I have an old Powerbook G4 12" I use for music, and while that has a DHCP-assigned IP address, it's not getting any network throughput to either LAN or internet addresses. To make matters more strange, my phone appears to be intermittently working when it's on the wifi. The access point is a Netgear WPN802v1, DHCP, NAT both switched off, running firmware 2.0.9.0. Last night I set it up with exactly the same settings, and similar to tonight I could get a couple of devices to work, and a couple not to. By the morning, however, everything had stopped working - nothing could get a DHCP IP address. I rebooted the 877W earlier this evening and I'm wondering whether this is why a few things are working now. "Could it be possible that the issue could be with the 877W?" I didn't configure this - is it possible that the DHCP server only likes assigning devices that are immediately attached to it? Or similar, could a firewall be stopping too many addresses that are coming through one device? (ie. the Access Point) This could explain why devices are working at the start but then not by the end. In reply to your questions, "1. I looked at the Netgear DG834G support page. There are five versions of this router. Which version do you have? Netgear usually lists this on the label on the bottom of the router. What version of the firmware does it have?" It's a DG834Gv3, and the firmware is the last on the netgear site version 4.01.40. "3. Not knowing which version you have, I glanced at the reference manual for the DG834G v3. In the section for Wireless Settings under the subsection Wireless Access Point there is a check box for a Wireless Isolation setting. If you have this setting it should be off/unchecked. If it is checked then any device connected via wireless would not be able to talk to any other device on the LAN. This sounds like your problem so maybe this is the cause?" I've checked this and it's switched off. I've made a change to the IP of the access point to something outside the DHCP range - it's now 192.158.153.5, with DHCP starting at 11 and going up to 254. Thanks for the tip about this - I only have a few devices so wouldn't anticipate the DHCP server assigning up to 110, but better safe than sorry. Finally one more thing I thought I should add, is with the Powerbook G4 that's not working - it's getting a DHCP IP address and it can communicate with the WPN802 as I can visit the administration page. Anything further than this, however, it can't reach; I can't administrate the 192.168.153.1 (877W router). Strangely, however, when I open Finder on the same powerbook it's detecting my NAS which is attached directly via wire to the 877W. If I try to browse it, it says connection failed. RE: "Perhaps the problem with your Powerbook is with DNS?.." The IP settings on the powerbook are identical to that of the PC with the exception of the IP address; the PC is 192.168.153.17 and the powerbook is 192.168.153.12. Subnets are the same, 255.255.255.0 and default gateway is the same, .1, and the DNS servers are the same. I administrate the 877W by going to 192.168.153.1 in the browser. This is what isn't working from the Powerbook, despite the PC working fine when I do the same. Meanwhile, however, I can administrate the AP on 192.168.153.5 from both PC and Powerbook Update 06/07/2010 - FINAL RESOLUTION of sorts: First off, sorry for the length of this question. I need start to practice a more concise writing style, so I'm going to try to keep this bit brief. After much fiddling, and with the hugely-appreciated help of irrational John, I have come to the conclusion that it's something wrong with the powerbook. I believe that this was perhaps the reason I doubted things worked at the very beginning. I now have the original DG834Gv3 running both wirelessly and wired, and both wired devices and wireless devices get internet connectivity. The only anomaly is the powerbook which I've had to keep wired, as no matter what I do it refuses to work wirelessly. I still have suspicions that the 877W isn't quite right; I'm fairly sure that if I RJ45 the powerline adapter into a different LAN port on it then everything will break. I've just about run out of patience to test this further, and I think I need to go into the 877W's config to match the 877w's lan port's settings. I'm accepting irrational John's answer as he's been enormously helpful, way above the call of duty, and for this line he wrote: Beats the heck out of me. which in the midst of great frustration made me chuckle, and for a sentence in one of his comments to the same answer: If it is specific to the Powerbook I would put that issue aside until after you feel you have the rest of your LAN and the additional WAP all working together correctlyt It was this second sentence that made me put the powerbook aside and concentrate on the other devices that ultimately led me to getting things working.

    Read the article

  • Windows Cluster issue

    - by George2
    Hello everyone, For Windows Server 2008 failover cluster, I find it is dependent on Windows domain (in other words, Windows domain is pre-requisite of installing Windows Server 2008 fail over cluster). I am not sure why it is dependent on Windows domain? What features of Windows domain will Windows Server 2008 failover cluster utilize? thanks in advance, George

    Read the article

  • Why can't I change the domain when connecting to network shares in Windows 8?

    - by Nathan Osman
    I have a computer running Windows 8.1 Pro. I also have Ubuntu 12.04.3 Server running within Hyper-V on the same machine. The Ubuntu server has Samba installed. Both the host and guest OS are connected to the workgroup WORKGROUP. When I open up "Network" in Windows 8.1 and attempt to connect to the server (both by name and IP address), I receive the following prompt: Entering the correct username and password for an account on the server fails. /etc/samba/smb.conf has the following share definitions set: [homes] comment = Home Directories browseable = no

    Read the article

  • Windows SteadyState - system's security log is full

    - by Matt
    Quick version: New computer, attached to Windows domain, with SteadyState w/ Disk Protection turned on, cannot log on as domain user because Windows states 'system security log is full' Troubleshooting performed: disabled all 'restrictions' listed in SteadyState, cleared system security log, changed security log settings to overwrite entries when it becomes full, restarted computer to commit changes, verified changes were commited - still cannot log on as domain user, changed Documents and Settings folder to another partition, still cannot log on as domain user Let me know if you need a more detailed description of any steps performed. I appreciate any help you can give me.

    Read the article

  • MessageBox if Recordset Update is Successful

    - by Paolo Bernasconi
    In Access 2007, I have a form to add a new contact to a table: RecSet.AddNew RecSet![Code_Personal] = Me.txtCodePersonal.Value RecSet![FName] = Me.TxtFName.Value RecSet![LName] = Me.txtLName.Value RecSet![Tel Natel] = Me.txtNatTel.Value RecSet![Tel Home] = Me.txtHomeTel.Value RecSet![Email] = Me.txtEmail.Value RecSet.Update This has worked so far, and the contact has successfully been aded. But I'm having two problems: I want to display a messagebox to tell the user the contact was successfully added If the contact was not successfully added because A contact with this name already exists A different issue Then display a message box "Contact already exists" or "error occured" respectively. My idea of doing this is: If recSet.Update = true Then MsgBox "Paolo Bernasconi was successfully added" Else if RecSet![FName] & RecSet![LName] 'already exist in table MsgBox "Contact already exists" Else MsgBox "An unknown error occured" I know this code is wrong, and obviously doesn't work, but it's just to give you an idea of what I'm trying to achieve. Thanks for all your help in advance.

    Read the article

  • Two different sites, same IP, same top-level domain, on IIS 7.5 -- one works and the other displays HTTP 404 error

    - by user717236
    I'm running a Windows 2008 R2 box with IIS 7.5 as the web server. On IIS, I have two websites: mysubsite1.mysite.com and mysubsite2.mysite.com. There is only one IP on the server and both sites share this IP. Here is how I have the bindings configured: mysubsite1.mysite.com works fine. However, mysubsite2.mysite.com gives me the following error: Not Found HTTP Error 404. The requested resource is not found. Now, if I change the Host name field for mysubsite1.mysite.com to blank and restart the web server, both sites work! The question is why is the host name field for the first site causing an HTTP 404 error for the second site when both sites' Host name fields are filled? I would appreciate any insight. Thank you.

    Read the article

  • Converting DAO to ADO

    - by webworm
    I am working with an Access 2003 database that has a subroutine using DAO code. This code loops through the table definitions and refreshes the ODBC connection string. I would like to convert this to ADO so I do not have to reference the DAO object library. Here is the code ... Public Sub RefreshODBCLinks(newConnectionString As String) Dim db As DAO.Database Dim tb As DAO.TableDef Set db = CurrentDb For Each tb In db.TableDefs If Left(tb.Connect, 4) = "ODBC" Then tb.Connect = newConnectionString tb.RefreshLink Debug.Print "Refreshed ODBC table " & tb.Name End If Next tb Set db = Nothing MsgBox "New connection string is " & newConnectionString, vbOKOnly, "ODBC Links refreshed" End Sub The part I am unsure of is how to loop through the tables and get/set their connection strings.

    Read the article

  • Access Violation

    - by Justin
    I've been learning how to NOP functions in C++ or even C but there are very few tutorials online about it. I've been googling for the past few hours now and I'm just stuck. Here is my code. #include <iostream> #include <windows.h> #include <tlhelp32.h> using namespace std; //#define NOP 0x90 byte NOP[] = {0x90}; void enableDebugPrivileges() { HANDLE hcurrent=GetCurrentProcess(); HANDLE hToken; BOOL bret=OpenProcessToken(hcurrent,40,&hToken); LUID luid; bret=LookupPrivilegeValue(NULL,"SeDebugPrivilege",&luid); TOKEN_PRIVILEGES NewState,PreviousState; DWORD ReturnLength; NewState.PrivilegeCount =1; NewState.Privileges[0].Luid =luid; NewState.Privileges[0].Attributes=2; AdjustTokenPrivileges(hToken,FALSE,&NewState,28,&PreviousState,&ReturnLength); } DWORD GetProcId(char* ProcName) { PROCESSENTRY32 pe32; HANDLE hSnapshot = NULL; pe32.dwSize = sizeof( PROCESSENTRY32 ); hSnapshot = CreateToolhelp32Snapshot( TH32CS_SNAPPROCESS, 0 ); if( Process32First( hSnapshot, &pe32 ) ) { do{ if( strcmp( pe32.szExeFile, ProcName ) == 0 ) break; }while( Process32Next( hSnapshot, &pe32 ) ); } if( hSnapshot != INVALID_HANDLE_VALUE ) CloseHandle( hSnapshot ); return pe32.th32ProcessID; } void WriteMem(DWORD Address, void* Value, size_t Size) { DWORD Protect = NULL; VirtualProtect((LPVOID)Address, 3, PAGE_READWRITE, &Protect); memcpy((void*)Address, Value, 3); VirtualProtect((LPVOID)Address, 3, Protect, &Protect); } void nop_(PVOID address, int bytes){ DWORD d, ds; VirtualProtect(address, bytes, PAGE_EXECUTE_READWRITE, &d); memset(address, 144, bytes); VirtualProtect(address,bytes,d,&ds); } void MemCopy(HANDLE pHandle, void* Dest, const void* Src, int Len) { DWORD OldProtect; DWORD OldProtect2; VirtualProtect(Dest, Len, PAGE_EXECUTE_READWRITE, &OldProtect); memcpy(Dest, Src, Len); VirtualProtect(Dest, Len, OldProtect, &OldProtect2); FlushInstructionCache(pHandle, Dest, Len); } int main() { enableDebugPrivileges(); DWORD pid; HANDLE phandle; // Obtain the process ID pid = GetProcId("gr.exe"); if(GetLastError()) { cout << "Error_PID_: " << GetLastError() << endl; system("pause"); return -1; } // Obtain the process handle phandle = OpenProcess(PROCESS_ALL_ACCESS,0,pid); if(GetLastError()) { cout << "Error_HANDLE_: " << GetLastError() << endl; system("pause"); return -1; } // Debug info, 0 = bad cout <<"pid : " << pid << endl; cout <<"HANDLE: " << phandle << endl << endl; system("pause"); // Change value to short iValue = -1; int choice = 0; BYTE * bGodMode = (BYTE *) (0x409A7E); // Lives Address bool hack = true; while(hack) { system("cls"); cout << "What hack?\n0. Exit\n1. Lives\n\n!> "; cin >> choice; switch(choice) { case 0: { hack=false; break; } case 1: // Modify Time cout << "God Mode On\n!> "; // cin >> iValue; // nop_((PVOID)(0x409A7E), 3); // MemCopy(phandle, (PVOID)0x409A7E, &NOP, 1); WriteMem((DWORD)(0x00409A7E), (void*)NOP, sizeof NOP); if(GetLastError()) { cout << "Error: " << GetLastError() << endl; system("pause"); } break; default: cout << "ERROR!\n"; break; } Sleep(100); } system("pause"); return 0; } This is suppose to NOP the DEC function that is 3 bytes long preventing me from losing lives. However each time I try it, it crashes the hack and says I had a access violation. I tried to look up the reasons and most of them dealt with with the size of the location I'm writing to and what I'm copying from. Otherwise, I have absolutely no idea. Any help would be nice. The game is GunRoar and the base address "0x409A7E" is where the DEC function is.

    Read the article

  • New to programming

    - by Shaun
    I have a form (Quote) with an auto-number ID, on the form at the moment are two subforms that show different items (sub 1 shows partition modules sub 2 shows partition abutments) both forms use the same parts tables to build them. Both forms are linked to the quote form using the ID. All works well until the forms is refreshed or re-loaded, subform 1 shows the module names and quantities and blank spaces for the abutment names but shows the quantiews for the abutments, the reverse of this is shown in the abutments subform 2. When the lists for the variuos types and the detailed parts lists are printed they are correct. This seems to be only a visual problem. All based on Access 2003. Subform 1 SELECT Quote_Modules.ModuleID, Quote_Modules.QuoteID, Quote_Modules.ModuleDescription, Quote_Modules.ModuleQty, Quote.Style, Quote.Trim FROM Quote INNER JOIN Quote_Modules ON Quote.QuoteID=Quote_Modules.QuoteID ORDER BY Quote_Modules.ModuleID; Subform 2 SELECT Quote_Modules.ModuleID, Quote_Modules.QuoteID, Quote_Modules.ModuleDescription, Quote_Modules.ModuleQty, Quote.Style, Quote.Trim FROM Quote INNER JOIN Quote_Modules ON Quote.QuoteID=Quote_Modules.QuoteID ORDER BY Quote_Modules.ModuleID;

    Read the article

  • Cisco access list logging. Why is there a difference between IPv4 and IPv6?

    - by growse
    I've got a Cisco 877 router. I've got an IPv4 access list and an IPv6 access list set up and configured similar to this: interface Dialer1 ... ip access-group INTERET-IN ipv6 traffic-filter IPV6-IN Each of these access lists has a final rule of deny ip/ipv6 any any log. However, in my syslog I notice that there's a difference in formatting between the two types of entries. IPv4 will say: %SEC-6-IPACCESSLOGP: list INTERNET-IN denied udp 88.89.209.63(137) -> 1.2.3.4(137), 1 packet Whereas the IPv6 list will say %IPV6_ACL-6-ACCESSLOGNP: list IPV6-IN/240 denied 59 2001:0:5EF5:79FD:14F9:B773:3EBA:3EE3 (Dialer1) -> 2001:800:1000:0::1, 8 packets Both have broadly the same information, but the IPv6 log entry is missing the protocol type and port, both of which are very useful if I'm trying to troubleshoot connectivity. Why is this? How do I get IPv6 deny logs to display the protocol and port used, if any?

    Read the article

  • Passing report values to a query

    - by Beavis
    I'm a novice with Microsoft Access as my background is mostly .NET. I'm sure what I'm trying to accomplish is dead simple but I need some direction. I have a report and a query. The query returns a single numeric value based on a single numeric criteria. Select total from table where id = [topic] I have placed a text box on my report so I can feed the id to this query and in return get the total. It seems like DLookUp is what I want but no matter how I construct it, I get an "#Error" in the text box when I run the report. Currently my DLookUp looks like this (I just hard-coded now for simplicity): =DLookUp("[total]","myquery","[topic] = 3") How can I pass a value from a field on my report to a query so I can return the query's single numeric value? Thanks.

    Read the article

  • Dns.GetHostEntry is not giving me a good IP to pass to IPEndPoint function in my domain

    - by Beach Miles
    My c# code from my asynchronous socket client to get the address of my socket server. string testServerIP = "192.168.0.1"; IPHostEntry ipHostInfo = Dns.GetHostEntry(testServerIP); //time server address IPAddress ipAddress = ipHostInfo.AddressList[0]; IPEndPoint remoteEP = new IPEndPoint(ipAddress, port); I get the following error message from the above code. CheckServerReconnect:Cant connect to 192.168.0.1 The requested name is valid and was found in the database, but it does not have the correct associated data being resolved for

    Read the article

  • Query "where clause" fails when calling a function

    - by guest1
    Hi All, I have a function in Access VBA that takes four parameters.The fourth parameter is a "where clause" that I use in an SQL statement inside the function. The function fails when I include the fourth parameter (where clause). When I remove this fourth parameter, the function just works fine. I am not sure if there is anything wrong with the syntax of the fourth parameter ? Please help. here is the function as called in the Query FunctionA('Table1','Field1',0.3,'Field2=#' & [Field2] & '# and Value3="' & [Value3] & '"') AS Duration_Field

    Read the article

  • Wordpress Multisite- How to restrict a non-wordpress page only to one domain

    - by yibe
    I am running three blogs from a wordpress multisite. Currently, I am developing a separate, non wordpress application. I want to link this application with blog1. I put the application in the subfoler of my root directory (The Wordpress multisite is installed in the root). I linked the application in the menu of blog1. So far so good. But, it is possible to access the application from all the three blogs. I want the application to be accessible only from blog1-domain/my-app/ but when I tried blog2-domain/my-app, it just opened normally. Generally, the application is accessible from all the three domains followed by /my-app. I don't think it is proper to go this way. Then, what can I do to restrict my app to be accessible only from a my blog1-domain/my-app ? Or am I not using a good blog structure?. I am open to all kind of suggestions. Thank you for your help.

    Read the article

  • Getting started with Access Services —Part1

    - by ybbest
    In SharePoint2010, we can publish the access database to SharePoint and make the access database accessible to users using SharePoint site. Today, I’d like to show you how to publish the access database to SharePoint. 1. Open the access2010 and click New>>Sample templates 2. And then select Issues Web Database (you can select any web database here, I choose the Issues Web Database here) 3. The next step is to publish this access database to SharePoint, you can do so by going to File>>  Save & Publish>> Publish to Access Services 4. Finally, fill in the details of the SharePoint site and site name and publish the database to SharePoint2010.If you need to publish the access database to https SharePoint site, check my previous blog here. 5. You will see the “publish succeeded” 6. Navigate to the site you will see now your Access Database is available online.

    Read the article

< Previous Page | 107 108 109 110 111 112 113 114 115 116 117 118  | Next Page >