Search Results

Search found 5127 results on 206 pages for 'mscorwks dll'.

Page 111/206 | < Previous Page | 107 108 109 110 111 112 113 114 115 116 117 118  | Next Page >

  • Delphi How to wait for socket answer inside procedure?

    - by Astronavigator
    For some specific needs i need to create procedure that waits for socket request (or answer) in dll: TForm1 = class(TForm) ServerSocket1: TServerSocket; ...... procedure MyWaitProc; stdcall; begin Go := false; while not Go do begin // Wating... // Application.ProcessMessages; // Works with this line end; end; procedure TForm1.ServerSocket1ClientRead(Sender: TObject; Socket: TCustomWinSocket); begin MessageBoxA(0, PAnsiChar('Received: '+Socket.ReceiveText), '', MB_OK); Go := true; end; exports MyWaitProc; When I call Application.ProcessMessages everything works fine: application waits for request and then continues. But in my case calling Application.ProcessMessages causes to unlocking main form on host application (not dll's one). When I don't call Application.ProcessMessages application just hangs couse it cannot handle message... So, how to create such a procedure that's wating for socket answer ? Maybe there a way to wait for socket answer without using Application.ProcessMessages ? EDIT I also tried to use TIdTCPServer, for some reasons, the result is the same. TForm1 = class(TForm) IdTCPServer1: TIdTCPServer; ..... procedure MyWaitProc; stdcall; begin Go := false; while not Go do begin // Waiting ... // Application.ProcessMessages; end; end; procedure TForm1.IdTCPServer1Execute(AContext: TIdContext); var s: string; begin s := AContext.Connection.Socket.ReadString(1); AllText := AllText + s; Go := True; end;

    Read the article

  • HtmlAgilityPack - Vs 2010 - c# ASP - File Not found

    - by Janosch Geigowskoskilu
    First, I've already searched the web & StackOverflow for hours, and i did find a lot about troubleshooting HtmlAgilityPack and tried most of these but nothing worked. The Situation: I'm developing a C# ASP .NET WebPart in SharePoint Foundation. Everything works fine, now I want to Parse a HTML Page to get all ImagePaths and save the Images on HD/Temp. To do that I was downloading HtmlAgilityPack, current version, add reference to Project, everything looks OK, IntelliSense works fine. The Exception: But when I want to run the section where HtmlAgilityPack should be used my Browser shows me a FileNotFoundException - The File or Assembly could not be found. What I tried: After first searches i tried to include v1.4.0 of HtmlAgilityPack cause I read that the current version in some case is not really stable. This works fine to until the point I want to use HtmlAgilityPack, the same Exception. I also tried moving the HtmlAgilityPack direct to the Solution directory, nothing changed. I tried to insert HtmlAgilityPack via using and I tried direct call e.g. HtmlAgilityPack.HtmlDocument. Conclusion : When I compile no error occurs, the reference is set correct. When I trace the HtmlAgilityPack.dll with ProcMon the Path is shown correct, but sometimes the Result is 'File Locked with only Readers' but I don't know enough about ProcMon to Know what this means or if this is critical. It couldn't have something to do with File Permissions because if I check the DLL the permissions are all given.

    Read the article

  • Is it possible to write an IIS URL Rewrite Rule that examines content of HTTP Post?

    - by JohnRudolfLewis
    I need to split a portion of functionality away from a legacy ISAPI dll onto another solution (ASP.NET MVC most likely). IIS7's URL Rewrite sounded like a perfect candidate for the job, but it turns out I cannot find a way to configure the rules the way I need. I need to write a rule that examines the content of the HTTP post for a particular value. i.e. <form method="post" action="legacy_isapi.dll"> <input name="foo" /> </form> if (Request.Form["foo"] == "bar") Context.RewritePath("/some_other_url/on_the_same_machine/foo/bar"); As a proof of concept, I was able to create an IHttpModule that examines context.Request.Form collection and performs a rewrite when certain parameters are present. I installed this module in my website, and it works. Rather than a custom module, however, I'd rather extend the existing URL Rewrite module to support examining the content of the HTTP Post as one of its rules. Is this possible?

    Read the article

  • Really simple JSON serialization in .NET

    - by Evgeny
    I have some simple .NET objects I'd like to serialize to JSON and back again. The set of objects to be serialized is quite small and I control the implementation, so I don't need a generic solution that will work for everything. Since my assembly will be distributed as a library I'd really like to avoid a dependency on some third-party DLL: I just want to give users one assembly that they can reference. I've read the other questions I could find on converting to and from JSON in .NET. The recommended solution of JSON.NET does work, of course, but it requires distributing an extra DLL. I don't need any of the fancy features of JSON.NET. I just need to handle a simple object (or even dictionary) that contains strings, integers, DateTimes and arrays of strings and bytes. On deserializing I'm happy to get back a dictionary - it doesn't need to create the object again. Is there some really simple code out there that I could compile into my assembly to do this simple job? I've also tried System.Web.Script.Serialization.JavaScriptSerializer, but where it falls down is the byte array: I want to base64-encode it and even registering a converter doesn't let me easily accomplish that due to the way that API works (it doesn't pass in the name of the field).

    Read the article

  • Adding shortcut for WiX file in a different fragment.

    - by matt
    I'm using heat.exe to generate fragments similar to this: <Fragment> <DirectoryRef Id="INSTALLDIR"> <Component Id="id1" Guid="*"> <File Id="fid1" KeyPath="yes" Source="SourceDir\Foo1.dll" /> </Component> <Component Id="id2" Guid="*"> <File Id="fid2" KeyPath="yes" Source="SourceDir\Foo2.dll" /> </Component> <Component Id="id3" Guid="*"> <File Id="fid3" KeyPath="yes" Source="SourceDir\Bar.exe" /> </Component> </DirectoryRef> </Fragment> <Fragment> <ComponentGroup Id="Components"> <ComponentRef Id="id1" /> <ComponentRef Id="id2" /> <ComponentRef Id="id3" /> </ComponentGroup> </Fragment> These fragments are stored in the auto-generated wxs file. I'm then adding them into my feature (in the main WiX file) like so: <ComponentGroupRef Id="Components"/> This works fine. However, I'd also like to add a shortcut to Bar.exe to my start menu. I ideally want to do this in my main wix file, with the Bar.exe component still residing in the auto-generated wxs file. How would I approach this problem without modifying the auto-generated code?

    Read the article

  • WPF deployment strategy dilemma.clickonce(limited customization)+autoupdate vs installer(unlimited c

    - by black sensei
    Hello Experts!!! I've been facing a deployment problem.I've built a WPF application with visual studio 2008 and created an installer(msi) which works fine.But then it's pain to add automatic update to it. i've seen this article at windowsclient.net but it seems to be pretty old but could have been the perfect thing for me.Then i looked at the .Net Application updater block v2.0 which uses enterprise library june 2005 and for some reason it's not installing on my machine. I thought i will need to use a more recent Enterprise library so i installed and compiled Enterprise 4.1(october 2008) but nothing better happened.To i decided to give a try to CLickonce deployment.After struggling with it, it was almost perfect.I realized that when i was testing the updates provided by the clickonce on my machine which is XP i didn't notice the need of having sqlite dll in the GAC. surely it was already there.I noticed it when i moved to vista that there is a problem.After checking the net i know it's impossible to add a dll to the Global Assembly Cache. Now i'm stuck, i think i've hit a wall.Can any one share some of his experience? I'm willing to try the updater block if i can get help. Thanks for reading this!!

    Read the article

  • Cannot use await in Portable Class Library for Win 8 and Win Phone 8

    - by Harry Len
    I'm attempting to create a Portable Class Library in Visual Studio 2012 to be used for a Windows 8 Store app and a Windows Phone 8 app. I'm getting the following error: 'await' requires that the type 'Windows.Foundation.IAsyncOperation' have a suitable GetAwaiter method. Are you missing a using directive for 'System'? At this line of code: StorageFolder guidesInstallFolder = await Package.Current.InstalledLocation.GetFolderAsync(guidesFolder); My Portable Class Library is targeted at .NET Framework 4.5, Windows Phone 8 and .NET for Windows Store apps. I don't get this error for this line of code in a pure Windows Phone 8 project, and I don't get it in a Windows Store app either so I don't understand why it won't work in my PCL. The GetAwaiter is an extension method in the class WindowsRuntimeSystemExtensions which is in System.Runtime.WindowsRuntime.dll. Using the Object Browser I can see this dll is available in the .NET for Windows Store apps component set and in the Windows Phone 8 component set but not in the .NET Portable Subset. I just don't understand why it wouldn't be in the Portable Subset if it's available in both my targeted platforms.

    Read the article

  • updating system's time using .Net

    - by user62958
    I am trying to update my system time using the following: [StructLayout(LayoutKind.Sequential)] private struct SYSTEMTIME { public ushort wYear; public ushort wMonth; public ushort wDayOfWeek; public ushort wDay; public ushort wHour; public ushort wMinute; public ushort wSecond; public ushort wMilliseconds; } [DllImport("kernel32.dll", EntryPoint = "GetSystemTime", SetLastError = true)] private extern static void Win32GetSystemTime(ref SYSTEMTIME lpSystemTime); [DllImport("kernel32.dll", EntryPoint = "SetSystemTime", SetLastError = true)] private extern static bool Win32SetSystemTime(ref SYSTEMTIME lpSystemTime); public void SetTime() { TimeSystem correctTime = new TimeSystem(); DateTime sysTime = correctTime.GetSystemTime(); // Call the native GetSystemTime method // with the defined structure. SYSTEMTIME systime = new SYSTEMTIME(); Win32GetSystemTime(ref systime); // Set the system clock ahead one hour. systime.wYear = (ushort)sysTime.Year; systime.wMonth = (ushort)sysTime.Month; systime.wDayOfWeek = (ushort)sysTime.DayOfWeek; systime.wDay = (ushort)sysTime.Day; systime.wHour = (ushort)sysTime.Hour; systime.wMinute = (ushort)sysTime.Minute; systime.wSecond = (ushort)sysTime.Second; systime.wMilliseconds = (ushort)sysTime.Millisecond; Win32SetSystemTime(ref systime); } When I debug everything looks good and all the values are correct but when it calles the Win32SetSystemTime(ref systime) th actual time of system(display time) doesn't change and stays the same. The strange part is that when I call the Win32GetSystemTime(ref systime) it gives me the new updated time. Can someone give me some help on this?

    Read the article

  • how to make an import library

    - by user295030
    a requirement was sent to me below: API should be in the form of static library. company xxx will link the library into a third party application to prevent any possible exposure of the code(dll) could they mean an import library? An import library is a library that automates the process of loading and using a dynamic library. On Windows, this is typically done via a small static library (.lib) of the same name as the dynamic library (.dll). The static library is linked into the program at compile time, and then the functionality of the dynamic library can effectively be used as if it were a static library. this might be what they might be eluding to.....I am not sure how to make this in vs2008 . Additional facts: I have a static lib that i use in my current application. Now, I have to convert my app that uses that static lib into an import lib so that they can use a third party prog to access the API's they providede me which in turn will use that static lib i am using. I hope I am clearly explaining this. I am just not sure how to go about it in vs2008. I am looking for specific steps to do this. I already have the coding done. Just need to convert it into the form they are asking and I have to provide the API they want. Other than that then I need to create a test prog which will act as that third party prog so I can make sure my import library works.

    Read the article

  • Global resources can't be resolved after publishing Website in VS2008

    - by Scoregraphic
    Hi there I have a web-project running in VS 2008. We have some global resource files (*.resx) in the App_GlobalResources folder for internationalisation. All this works like a charm on my local IIS installation out of VS. But when I publish my web-project to the local filesystem and/or another server, all the resources can no longer be found. So I guess the pre-compilation is somehow corrupting stuff. When I call the pre-compiled web, I get an error that the resource object with key xyz cannot be found, although it could be found before. I checked with .NET reflector if the resource stuff made it into the *.dlls. All those identifiers are there (bin/Web.dll, bin/<culture>/Web.resources.dll). The identifiers are loaded like this: <asp:MenuItem NavigateUrl="~/OrderNew.aspx" Text="<%$ Resources:MyProject, MenuNewOrder %>" Value="NewOrder"> The resource files are called MyProject.resx and MyProject.<culture>.resx where <culture> corresponds the the specific culture (i.e. MyProject.de-DE.resx). Any ideas how to solve this? I really appreciate any help. Thanks Edit: If I copy the App_GlobalResources folder manually to the output, the resources may be loaded normally. So I really really wonder what this pre-compilation is all about. I'm still interested in solving the issue "the right way".

    Read the article

  • VS2010: Why do my custom Toolbox tabs and contained controls keep disappearing?

    - by Velika2
    This is how I expected the toolbox to work: Let's say I add a custom Tab to the Toolbox called "Ajaxtoolkit." To add controls to the new tab, I right mouse click and select "Choose Items" and browse to a file, Ajaxtoolkit.dll, that is of a particular version number. I would expect that when I save and reopen the solution, that the Ajax Toolkit custom tab would still be in my Toolbox and that it would contain the same controls that were there last time, the controls that were in the dll that I referenced when the controls were added. If I created a brand new web app, I (possibly) wouldn't expect to see the same Ajax Toolkit custom tab. However, I could perform the same steps as above and add a "Ajax Toolkit" tab and perhaps, this time, select a DIFFERENT VERSION of the tookit, and the state of the toolkit would be retained with each solution file. Another possibility would be for the original Ajaxtoolkit to be retained when the 2nd web solution is created, and perhaps, if I wanted to mix versions of the toolkit across diffreent web sites in my solution, I should start naming my custom toolkit tabs with version specific names like "Ajaxtoolkit 4.0," etc. ...But instead, the Ajaxtoolkit tab disappears when I close VS2010 and reopen it. Why? Is this desirable behavior or a bug?

    Read the article

  • OpenGL Calls Lock/Freeze

    - by Necrolis
    I am using some dell workstations(running WinXP Pro SP 2 & DeepFreeze) for development, but something was recenlty loaded onto these machines that prevents any opengl call(the call locks) from completing(and I know the code works as I have tested it on 'clean' machines, I also tested with simple opengl apps generated by dev-cpp, which will also lock on the dell machines). I have tried to debug my own apps to see where exactly the gl calls freeze, but there is some global system hook on ZwQueryInformationProcess that messes up calls to ZwQueryInformationThread(used by ExitThread), preventing me from debugging at all(it causes the debugger, OllyDBG, to go into an access violation reporting loop or the program to crash if the exception is passed along). the hook: ntdll.ZwQueryInformationProcess 7C90D7E0 B8 9A000000 MOV EAX,9A 7C90D7E5 BA 0003FE7F MOV EDX,7FFE0300 7C90D7EA FF12 CALL DWORD PTR DS:[EDX] 7C90D7EC - E9 0F28448D JMP 09D50000 7C90D7F1 9B WAIT 7C90D7F2 0000 ADD BYTE PTR DS:[EAX],AL 7C90D7F4 00BA 0003FE7F ADD BYTE PTR DS:[EDX+7FFE0300],BH 7C90D7FA FF12 CALL DWORD PTR DS:[EDX] 7C90D7FC C2 1400 RETN 14 7C90D7FF 90 NOP ntdll.ZwQueryInformationToken 7C90D800 B8 9C000000 MOV EAX,9C the messed up function + call: ntdll.ZwQueryInformationThread 7C90D7F0 8D9B 000000BA LEA EBX,DWORD PTR DS:[EBX+BA000000] 7C90D7F6 0003 ADD BYTE PTR DS:[EBX],AL 7C90D7F8 FE ??? ; Unknown command 7C90D7F9 7F FF JG SHORT ntdll.7C90D7FA 7C90D7FB 12C2 ADC AL,DL 7C90D7FD 14 00 ADC AL,0 7C90D7FF 90 NOP ntdll.ZwQueryInformationToken 7C90D800 B8 9C000000 MOV EAX,9C So firstly, anyone know what if anything would lead to OpenGL calls cause an infinite lock,and if there are any ways around it? and what would be creating such a hook in kernal memory ? Update: After some more fiddling, I have discovered a few more kernal hooks, a lot of them are used to nullify data returned by system information calls(such as the remote debugging port), I also managed to find out the what ever is doing this is using madchook.dll(by madshi) to do this, this dll is also injected into every running process(these seem to be some anti debugging code). Also, on the OpenGL side, it seems Direct X is fine/unaffected(I ran one of the DX 9 demo's without problems), so could one of these kernal hooks somehow affect OpenGL?

    Read the article

  • Compiling gstreamer plugin in windows

    - by utnapistim
    Hello all, My question: What is the correct way to compile a gstreamer plugin in windows, so that it will be accepted by gstreamer (actually Songbird on top of gstreamer). My setup: I have downloaded the songbird sources following the steps described here and I have a trunk/dependencies/windows-i686-msvc8 directory within my svn sources with all the gstreamer binaries. I have created a gstreamer empty plugin skeleton following the steps detailed in the GStreamer Plugin Writer's Guide, and compiled it against the gstreamer binaries in the Songbird dependencies folder. The compilation was done with VS2010 RC1 (Visual Studio 2008 yelded the same results), using an empty DLL project with the .h and .c files generated using the GStreamer Plugin Writer's Guide. The DLL was lined with libcpmt.lib, libcmt.lib, ws2_32.lib, gobject-2.0.lib, gthread-2.0.lib, gstreamer-0.10-0.lib, glib-2.0.lib, kernel32.lib, nspr4.lib and ignoring all default libraries. I have compiled the files as both .c and .cpp with the same results. Testing: I have installed the Songbird binaries corresponding to the correct svn version, then installed Songbird Developer Tools addon and used it to create an addon for testing my gstreamer plugin. Songbird will not load the pluggin. I have also tried to load it with gst-launch.exe from the trunk/dependencies/windows-i686-msvc8/[...] directory and that generated runtime error R6034: An application has made an attempt to load the C runtime library incorrectly. Most resources I found for this problem recommended restarting or reinstalling windows :(.

    Read the article

  • Send Click Message to another application process

    - by Nazar
    Hi Guys I have a scenario, i need to send click events to an independent application. I started that application with the following code. private Process app; app = new Process(); app.StartInfo.FileName = app_path; app.StartInfo.WorkingDirectory = dir_path; app.Start(); Now i want to send Mouse click message to that applicaiton, I have specific coordinates in relative to application window. How can i do it using Windows Messaging or any other technique. I used [DllImport("user32.dll")] private static extern void mouse_event(UInt32 dwFlags, UInt32 dx, UInt32 dy, UInt32 dwData, IntPtr dwExtraInfo); It works well but cause the pointer to move as well. So not fit for my need. Then i use. [DllImport("user32.dll", CharSet = CharSet.Auto, SetLastError = false)] static extern IntPtr SendMessage(IntPtr hWnd, int Msg, int wParam, int lParam); It works well for minimize maximize, but do not work for mouse events. The codes for mousevents i am using are, WM_LBUTTONDOWN = 0x201, //Left mousebutton down WM_LBUTTONUP = 0x202, //Left mousebutton up WM_LBUTTONDBLCLK = 0x203, //Left mousebutton doubleclick WM_RBUTTONDOWN = 0x204, //Right mousebutton down WM_RBUTTONUP = 0x205, //Right mousebutton up WM_RBUTTONDBLCLK = 0x206, //Right mousebutton do Thanks for the help in advance, and waiting for feedback.

    Read the article

  • IIS not responding to the few requests from the client

    - by Haroon
    I am stuck with an issue with IIS 7.0. I need someone's help to find resolution on this, as this is very urgent requirement for us. Scenario I am trying to host the service in my server (Windows Server 2008 R2 and IIS 7.0) and my client is running in the XP machine with IIS 5.1. Few of my request sent from client get successful response and for few request I am getting the below exception in Visual studio when I try to debug. Exception in Visual studio 2010 An error occurred while receiving the HTTP response to This could be due to the service endpoint binding not using the HTTP protocol. This could also be due to HTTP request context being aborted by the server (possibly due to the service shutting down). See the server logs for more details. When referred to the server event viewer log I got the below events(Application error and System warning) during the above exception. Under System logs - Warning A process serving application pool 'DefaultAppPool' suffered a fatal communication error with the Windows Process Activation Service. The process id was '5372'. The data field contains the error number. Under Application log - Error Faulting application name: w3wp.exe, version: 7.5.7600.16385, time stamp: 0x4a5bd0eb Faulting module name: ntdll.dll, version: 6.1.7600.16559, time stamp: 0x4ba9b802 Exception code: 0xc0000374 Fault offset: 0x00000000000c6df2 Faulting process id: 0x14fc Faulting application start time: 0x01cbd042562e92c3 Faulting application path: c:\windows\system32\inetsrv\w3wp.exe Faulting module path: C:\Windows\SYSTEM32\ntdll.dll Report Id: 95f76467-3c35-11e0-a46e-7071bc5cc1ee From internet I am not able to get the exact solution. Therefore could anyone please help me out from getting resolution for the same that would be really a great help for me. Please let me know if you need more details. Thanks in advance.

    Read the article

  • Module not found

    - by TMP
    Hi There! I've been working on this one quite a bit and haven't gotten any closer to a solution. I juut dug up my old copy of the WindowsHookLib again - It's available with source at http://www.codeproject.com/KB/DLL/WindowsHookLib.aspx. This library allows Global Windows Mouse/Keyboard/Clipboard Hooks, which is very useful. I'm trying to use the Mouse Hook in here to Capture Mouse-Motion (I could use a Timer that always polls Cursor.Position, but I plan on using more features of WindowsHookLib later). Code as follows: MouseHook mh = new MouseHook(); mh.InstallHook(); mh.MouseMove += new EventHandler<WindowsHookLib.MouseEventArgs>(mh_MouseMove); But on the call to InstallHook(), I get an Exception: "The specified Module could not be found". Strange. Searching, I found that someone thought this occurs because a DLL is not in a place included in the Windows PATH variable, and because placing it in system32 didn't help I went the whole hog and translated the thing to C# for inclusion directly in my project (I was curious how it works). However the error was obstinately persistent, so I dug a bit on this, and found the Code in the Library that is responsible: In InstallHook(), we have IntPtr hinstDLL = Marshal.GetHINSTANCE(Assembly.GetExecutingAssembly().GetModules()[0]); this._hMouseHook = UnsafeNativeMethods.SetWindowsHookEx(14, this._mouseProc, hinstDLL, 0); if (this._hMouseHook == IntPtr.Zero) { throw new MouseHookException(new Win32Exception(Marshal.GetLastWin32Error()).Message); } And this (after modification and recompile) tells me that what I'm really getting is a Windows error "ERROR_MOD_NOT_FOUND"! Now, Here I'm stumped. Didn't I just compile the Hook Library directly into my project? (UnsafeMethods.SetWindowsHookEx is just a DllImported Method from user32) Any Answers, or Prods in the right direction, or any hints, pointers or similar are very much appreciated!

    Read the article

  • A question about writing a background/automatic/silent downloader/installer for an app in C#.

    - by Mike Webb
    Background: I have a main application that needs to be able to go to the web and download DLL files associated with it (ones that we write, located on our server). It really needs to be able to download these DLL files to the application folder in "C:\Program Files\". In the past I have used System.Net.WebClient to download whatever files I wanted from the web. The Issue I have had a lot of trouble downloading data in the past and saving to files on a user's hard drive. I get many reports of users saying that this does not work and it is generally because of user rights issues in the program. In the cases where it was an issue with program user rights every user could go to the exact file location on the web, download it, and then save it to the right place manually. I want this to work like all the other programs I have seen download/install in this fassion (i.e. Firefox Pluign Updates, Flash Player, JAVA, Adobe Reader, etc). All of these work without a hitch. The Question Is there some code I need to use to give my downloader program special rights to the Program Files folder? Can I even do this? Is there a better class or library that I should use? Is there a different approach to downloading files I should take, such as using threads or something else to download data? Any help here is appreciated. I want to try to stay away from third-party apps/libraries if at all possible, other than Microsoft of course, due to licensing issues, but still send any suggestions my way. Again, other programs seem to have the rights issues and download capability figured out. I want this same capability.

    Read the article

  • Some web pages (especially Apple documentation) cause heavy CPU usage in Windows IE8

    - by Mark Lutton
    Maybe this belongs in Server Fault instead, but some of you may have noticed this issue (particularly those developing on Mac, using a Windows machine to read the reference material). I posted the same question on a Microsoft forum and got one answer from someone who reproduced the problem, so it's not just my machine. No solution yet. Ever since this month's security updates, I find that many web pages cause the CPU to run at maximum for as long as the web page is visible. This happens in both IE7 and IE8 on at least three different computers (two with Windows XP, one with Vista). Here is one of the pages, running on XP with IE 8: http://learning2code.blogspot.com/2007/11/update-using-subversion-with-xcode-3.html Here is one that does it in Vista with IE8: http://developer.apple.com/iphone/library/documentation/Cocoa/Reference/Foundation/Classes/NSString_Class/Reference/NSString.html You can leave the page open for hours and the CPU is still at high usage. This doesn't happen every time. It is not always reproduceable. Sometimes it is OK the second or third time it loads. In IE7 the high usage is in ieframe.dll, version 7.0.6000.16890. In IE8 the high usage is in iertutil.dll, version 8.0.6001.18806.

    Read the article

  • What scenarios are possible where the VS C# compiler would not compile a reference of a reference?

    - by SuperKing
    Hello, I'm probably asking this question wrong (and that may be why Google isn't helping), but here goes: In Visual Studio I am compiling a C# project (let's call it Project A, the startup project) which has a reference to Project B. Project B has a reference to a Project C, so when A gets built, the dlls for B gets placed in the bin directory of A, as does the dll for C (because B requires C, and A requires B). However, I have apparently made some change recently so that the dll for Project C does not go into the bin directory of Project A when rebuilding the solution. I have no idea what I've done to make this happen. I have not modified the setup of the solution itself, and I have only added additional references to the project files. Code wise, I have commented out most of the actual code in Project B that references classes in Project C, but did not remove the reference from the project itself (I don't think this matters). I was told that perhaps the C# compiler was optimizing somehow so that it was not building Project C, but really I'm out of ideas. I would think someone has run into something similar before Any thoughts? Thanks!

    Read the article

  • Pump Messages During Long Operations + C# (it is urgent)

    - by Newbie
    Hi I have a web service that is doing huge computation and is taking more than a minute. I have generated the proxy file of the web service and then from my client end I am using the dll(of course I generated the proxy dll). My client side code is TimeSeries3D t = new TimeSeries3D(); int portfolioId = 4387919; string[] str = new string[2]; str[0] = "MKT_CAP"; DateRange dr = new DateRange(); dr.mStartDate = DateTime.Today; dr.mEndDate = DateTime.Today; Service1 sc = new Service1(); t = sc.GetAttributesForPortfolio(portfolioId, true, str, dr); But since it is taking to much time for the server to compute, after 1 minute I am receiving an error message The CLR has been unable to transition from COM context 0x33caf30 to COM context 0x33cb0a0 for 60 seconds. The thread that owns the destination context/apartment is most likely either doing a non pumping wait or processing a very long running operation without pumping Windows messages. This situation generally has a negative performance impact and may even lead to the application becoming non responsive or memory usage accumulating continually over time. To avoid this problem, all single threaded apartment (STA) threads should use pumping wait primitives (such as CoWaitForMultipleHandles) and routinely pump messages during long running operations. Kindly guide me what to do? It is very urgent. Thanks

    Read the article

  • how to make the printer window appear using vb.net 2010

    - by Jeline Esase
    hi I have this code that will send my panel into a printer but the problem is it doesent let me choose which printer I will use any idea on how can I make the printer window appear? thanks Public Class Form1 Dim img As Bitmap Dim WithEvents pd As PrintDocument 'Returns the Form as a bitmap Function CaptureForm1() As Bitmap Dim g1 As Graphics = Me.CreateGraphics() Dim MyImage = New Bitmap(Me.ClientRectangle.Width, (Me.ClientRectangle.Height), g1) Dim g2 As Graphics = Graphics.FromImage(MyImage) Dim dc1 As IntPtr = g1.GetHdc() Dim dc2 As IntPtr = g2.GetHdc() BitBlt(dc2, 0, 0, Me.ClientRectangle.Width, (Me.ClientRectangle.Height), dc1, 0, 0, 13369376) g1.ReleaseHdc(dc1) g2.ReleaseHdc(dc2) 'saves image to c drive just, u can comment it also 'MyImage.Save("c:\abc.bmp") Return MyImage End Function <DllImport("gdi32.DLL", EntryPoint:="BitBlt", _ SetLastError:=True, CharSet:=CharSet.Unicode, _ ExactSpelling:=True, _ CallingConvention:=CallingConvention.StdCall)> _ Private Shared Function BitBlt(ByVal hdcDest As IntPtr, ByVal nXDest As Integer, ByVal nYDest As Integer, ByVal nWidth As Integer, ByVal nHeight As Integer, ByVal hdcSrc As IntPtr, ByVal nXSrc As Integer, ByVal nYSrc As Integer, ByVal dwRop As System.Int32) As Boolean ' Leave function empty - DLLImport attribute forwards calls to MoveFile to ' MoveFileW in KERNEL32.DLL. End Function Private Sub Button1_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles Button1.Click img = CaptureForm1() pd = New PrintDocument pd.Print() End Sub 'this method will be called each time when pd.printpage event occurs Sub pd_PrintPage(ByVal sender As Object, ByVal e As PrintPageEventArgs) Handles pd.PrintPage Dim x As Integer = e.MarginBounds.X Dim y As Integer = e.MarginBounds.Y e.Graphics.DrawImage(img, x, y) e.HasMorePages = False End Sub End Class

    Read the article

  • How do I debug into an ILMerged assembly?

    - by Rory Becker
    Summary I want to alter the build process of a 2-assembly solution, such that a call to ILMerge is invoked, and the build results in a single assembly. Further I would like to be able to debug into the resultant assembly. Preparation - A simple example New Solution - ClassLibrary1 Create a static function 'GetMessage' in Class1 which returns the string "Hello world" Create new console app which references the ClassLibrary. Output GetMessage from main() via the console. You now have a 2 assembly app which outputs "Hello World" to the console. So what next..? I would like to alter the Console app build process, to include a post build step which uses ILMerge, to merge the ClassLibrary assembly into the Console assembly After this step I should be able to: Run the Console app directly with no ClassLibrary1.dll present Run the Console app via F5 (or F11) in VS and be able to debug into each of the 2 projects. Limited Success I read this blogpost and managed to achieve the merge I was after with a post-build command of... "$(ProjectDir)ILMerge.bat" "$(TargetDir)" $(ProjectName) ...and an ILMerge.bat file which read... CD %1 Copy %2.exe temp.exe ILMerge.exe /out:%2.exe temp.exe ClassLibrary1.dll Del temp.exe Del ClassLibrary1.* This works fairly well, and does in fact produce an exe which runs outside the VS environment as required. However it does not appear to produce symbols (.pdb file) which VS is able to use in order to debug into the code. I think this is the last piece of the puzzle. Does anyone know how I can make this work? FWIW I am running VS2010 on an x64 Win7 x64 machine.

    Read the article

  • Add webservice reference, the classes in different file

    - by ArunDhaJ
    Hi, When I add webservice as service reference in my .Net project, it creates a service folder within "Service References". All the interfaces and classes are contained within that service folder. I wanted to know how to split the interface's method and classes. Actually I wanted the web service reference to import classes defined in different dll. I wanted to define this way because of my design constraints. I've 3 layered application. Of which third layer is communication layer which holds all web service references. second is business layer and first is presentation layer. If the class declarations are in layer-3 and I'm accessing those classes from presentation layer, it is logically a cross-layer-access-violation. Instead, I wanted a separate project which holds only the class declarations and this would be used in all 3 layers. I didn't faced any problems to achieve this with layer-1 and layer-2. But, I'm not sure how to make communication layer to use this common declaration dll. Your suggestion would help me to design my application better. Thanks in advance Regards ArunDhaJ

    Read the article

  • Pump Messages During Long Operations + C#

    - by Newbie
    Hi I have a web service that is doing huge computation and is taking more than a minute. I have generated the proxy file of the web service and then from my client end I am using the dll(of course I generated the proxy dll). My client side code is TimeSeries3D t = new TimeSeries3D(); int portfolioId = 4387919; string[] str = new string[2]; str[0] = "MKT_CAP"; DateRange dr = new DateRange(); dr.mStartDate = DateTime.Today; dr.mEndDate = DateTime.Today; Service1 sc = new Service1(); t = sc.GetAttributesForPortfolio(portfolioId, true, str, dr); But since it is taking to much time for the server to compute, after 1 minute I am receiving an error message The CLR has been unable to transition from COM context 0x33caf30 to COM context 0x33cb0a0 for 60 seconds. The thread that owns the destination context/apartment is most likely either doing a non pumping wait or processing a very long running operation without pumping Windows messages. This situation generally has a negative performance impact and may even lead to the application becoming non responsive or memory usage accumulating continually over time. To avoid this problem, all single threaded apartment (STA) threads should use pumping wait primitives (such as CoWaitForMultipleHandles) and routinely pump messages during long running operations. Kindly guide me what to do? Thanks

    Read the article

  • Implementing MEF with ASP.NET MVC?

    - by mark smith
    I am trying to find out if anyone has any experience or ideas of using MEF (Managed Extensible Framework (Microsoft's new plugin framework) with ASP.NET MVC. I need to create a standard ASP.NET MVC, which I have. But I need to offer additional functionality i.e. Views and Controllers, etc, depending on if I add a plugin. It doesn't need to be dynamically compiled i.e. source code... but a DLL that i put into the system.. Is there any way to dynamically load a DLL when the app starts, and then MERGE a VIEWS and CONTROLLERS with the main system? I don't know if i am on the right track here. Then, I suppose in the "STANDARD" views that come with the app, I can use an "IF THEN" to find out if a plugin is loaded and MERGE in a user control. Well, I'm talking out loud here, but I think you understand what I am getting at. Any ideas?

    Read the article

< Previous Page | 107 108 109 110 111 112 113 114 115 116 117 118  | Next Page >